Tender For Construction And Development Works Under O.K. Vihar Residential Scheme, Including Kela Khand Phase (1 & 2) And Sector 8, Covering An 18.0-Metre-Wide Main Road, Sewer Lines, Drains, Trenches, And Water Supply Infrastructure.
Tender Overview
Project Description
Tender For Construction And Development Works Under O.K. Vihar Residential Scheme, Including Kela Khand Phase (1 & 2) And Sector 8, Covering An 18.0-Metre-Wide Main Road, Sewer Lines, Drains, Trenches, And Water Supply Infrastructure.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :, All kinds of soil, Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm. |
| 2 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc., complete. |
| 3 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 4 | Plant Mix Method Construction of granular sub-base by providing close graded Material,mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 |
| 5 | Wet Mix Macadam (Plant Mix Method) Providing laying spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub - base / base course on well prepared surface and compacting with vibratory roller to achive the desired density |
| 6 | Pr5.07/510 MoRTH)oviding, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using Viscosity grade bitumen to required line, grade and level to seve as wearing course on a previously prepared base, including mixing in a suitable hot mix plant of appropriate capacity not less than 200 thnnes/hour, laying and rolling with a smooth wheeled roller, finished to required level and grades. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 8 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR No. 16.69 |
| 9 | Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. |
| 10 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge., 60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :, same as item 21 above but on new wood surface |
| 12 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge., All kinds of soil |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for :, Centering and shuttering including strutting and propping and removal of items for: Foundations, footings, base of columns, etc DSR 2023/5.9.1 |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for :, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for :, Suspended floors, roofs, landings, balconies and access platform |
| 18 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality, H D - 20, Circular shape 560 mm internal diameter |
| 19 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :, All kinds of soil, Pipes, cables etc, not exceeding 80 mm dia. |
| 20 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :, All kinds of soil, Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 21 | Providing and filling sand of grading zone V or coarser grade all- round the G.I. pipes in external work., 100 mm diameter pipe |
| 22 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :, 250 mm dia. R.C.C. pipe |
| 23 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia |
| 24 | Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.l. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:, With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 25 | Providing, supplying, laying, jointing, testing and commissioning Double Wall Corrugated (DWC) HDPE Sewer Pipe conforming to IS 16098 (Part 2) and latest amendments, manufactured from virgin HDPE material with corrugated outer wall and smooth inner wall, having minimum ring stiffness of SN-8 (8 kN/m²), suitable for underground gravity sewerage applications. The pipe shall be provided with integral socket/spigot ends or HDPE couplers with EPDM rubber sealing rings to ensure watertight joints. The work shall include bed preparation, laying to required line and gradient, jointing, testing for leakage, backfilling with selected material, compaction, handling, loading, unloading, transportation and all accessories complete in accordance with CPHEEO Manual, manufacturer's specifications and directions of the Engineer-in-Charge. The rate shall include all labour, materials, tools, plant and equipment required for complete installation and commissioning in all respects. |
| 26 | Providing, supplying, laying, jointing, testing and commissioning Double Wall Corrugated (DWC) HDPE Sewer Pipe conforming to IS 16098 (Part 2) and latest amendments, manufactured from virgin HDPE material with corrugated outer wall and smooth inner wall, having minimum ring stiffness of SN-8 (8 kN/m²), suitable for underground gravity sewerage applications. The pipe shall be provided with integral socket/spigot ends or HDPE couplers with EPDM rubber sealing rings to ensure watertight joints. The work shall include bed preparation, laying to required line and gradient, jointing, testing for leakage, backfilling with selected material, compaction, handling, loading, unloading, transportation and all accessories complete in accordance with CPHEEO Manual, manufacturer's specifications and directions of the Engineer-in-Charge. The rate shall include all labour, materials, tools, plant and equipment required for complete installation and commissioning in all respects. |
| 27 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :, 150 mm diameter S.W. pipe |
| 28 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :, 250 mm diameter S.W. pipe |
| 29 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :, 300 mm diameter S.W. pipe |
| 30 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :, 0.91 m deep with S.F .R.C. cover and frame (heavy duty , HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 31 | Extra depth for circular type manhole 0.91 m internal dia (at bottom) beyond 0.91 m to 1.67 m, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 32 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :, 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 33 | Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 34 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :, 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 35 | Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 36 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 1 12 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 37 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.l. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:, With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 38 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :, With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 39 | Providing and laying D.I. Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :, Up to 600 mm dia |
| 40 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :, 100 mm dia Ductile Iron Class K-7 pipes |
| 41 | Providing and fixing Polyethylene- Aluminium- Polyethylene (PE-AL- PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducers, couplers & connectors etc. with trenching, refilling and testing of joints complete as per direction of the engineer in charge : External work, 2025 (25 mm OD ) pipe. |
| 42 | Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory., 100 mm diameter C.I. pipe |
| 43 | C.I. Washout/Scour Valve 100 mm dia valve |
| 44 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :, 15 mm nominal bore |
| 45 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re- olling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 46 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom |
| 47 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift, All kinds of soil |
| 48 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :, 100 mm dia nominal bore |
| 49 | Providing, supplying, laying, jointing, testing and commissioning Double Wall Corrugated (DWC) HDPE Sewer Pipe conforming to IS 16098 (Part 2) and latest amendments, manufactured from virgin HDPE material with corrugated outer wall and smooth inner wall, having minimum ring stiffness of SN-8 (8 kN/m²), suitable for underground gravity sewerage applications. The pipe shall be provided with integral socket/spigot ends or HDPE couplers with EPDM rubber sealing rings to ensure watertight joints. The work shall include bed preparation, laying to required line and gradient, jointing, testing for leakage, backfilling with selected material, compaction, handling, loading, unloading, transportation and all accessories complete in accordance with CPHEEO Manual, manufacturer's specifications and directions of the Engineer-in-Charge. The rate shall include all labour, materials, tools, plant and equipment required for complete installation and commissioning in all respects. |
| 50 | Providing, supplying, laying, jointing, testing and commissioning Double Wall Corrugated (DWC) HDPE Sewer Pipe conforming to IS 16098 (Part 2) and latest amendments, manufactured from virgin HDPE material with corrugated outer wall and smooth inner wall, having minimum ring stiffness of SN-8 (8 kN/m²), suitable for underground gravity sewerage applications. The pipe shall be provided with integral socket/spigot ends or HDPE couplers with EPDM rubber sealing rings to ensure watertight joints. The work shall include bed preparation, laying to required line and gradient, jointing, testing for leakage, backfilling with selected material, compaction, handling, loading, unloading, transportation and all accessories complete in accordance with CPHEEO Manual, manufacturer's specifications and directions of the Engineer-in-Charge. The rate shall include all labour, materials, tools, plant and equipment required for complete installation and commissioning in all respects. |
| 51 | Providing and fixing Polyethylene- Aluminium- Polyethylene (PE-AL- PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required ) e.g. elbows, tees, reducers, couplers & connectors etc. with trenching, refilling and testing of joints complete as per direction of the engineer in charge : External work, 2532 (32 mm OD ) pipe. |
| 52 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :, 20 mm nominal bore |
| 53 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main :, 25 mm nominal bore |
| 54 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete, 450 mm dia RCC pipes. |
| 55 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :, 500 mm dia. R.C.C. pipe |
| 56 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete, 600 mm dia RCC pipes. |
| 57 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete, 1000 mm dia RCC pipes. (Laying by manual/ mechanical means) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender