Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #58481331

Bids Are invited for Repair And Replacement Of 11 Kv Ct Pt Metering Unit Pcda Jammu

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Nov 2026
2 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
1659

Project Description

Bids Are invited for Supply Fixing And Replacement Of 11Kv Ct Pt - Supply Fixing And Replacement Of 11Kv Ct Pt Metering Unit With Ratio 30 5 Frequency 50Hz No Of Ct Three And No Of Pt Three All Complete As Specified And Directed , Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm - Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 4 Core For Connection Of Ht Meter With Ct Pt All Complete As Specifiued And Directed , Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 3 Core - Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 3 Core For Connection Of Ht Meter With Ct Pt All Complete As Specifiued And Directed , Supply Fixing And Replacement Of Dg Set Start - Supply Fixing And Replacement Of Dg Set Start Manual On Off Panel Suitable For 320 Kva Dg Set All Complete As Specified And Directed , Supply Fixing And Replacement Of End Termination Lungs - Supply Fixing And Replacement Of End Termination Lungs For Connection Of Ct And Pt All Complete As Specified And Directed , Supply Laying Commissioning Ug Cable Xlpe Insulated - Supply Laying Commissioning Ug Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty 1100 Volts Grade With Stranded Aluminium Conductor Of Size 50 Sq Mm 3.5 Core Cable Complete All As Specified And Directed , Excavation In Trenches Not Exceeding 1.5M Wide - Excavation In Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth And Getting Out In Any Type Of Soil For Laying Of Lt Ug Cables Complete All As Specified And Directed , Returning Filling In Including Spreading Levelling Watering - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Hard Dense Soil Complete All As Specified And Directed , Removing Excavated Material Not Exceeding 50M - Removing Excavated Material Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed , Material And Labour For Sand Cushioning Below - Material And Labour For Sand Cushioning Below And Around Cable In Trenches With Rever Sand All As Specified . , Material And Labour For Unreinforced Precast Concrete Cable - Material And Labour For Unreinforced Precast Concrete Cable Cover Class Lv Type 1 Flat Of Size 250 X 150 X 40 Mm For Cable Protection Complete All As Specified And As Directed By Eic , Supply And Fixing Gi Tubing Light Grade 80 Mm - Supply And Fixing Gi Tubing Light Grade 80 Mm Bore On Poles Under Floors Road Crossing Etc All As Reqd At Site And As Directed By , Material And Labour For Servicing Overhauling Of Dg Sets Of - Material And Labour For Servicing Overhauling Of Dg Sets Of Capacity 63 Kva And 320 Kva Including Carrying Out Maintenance And Check Alongwith Following Repairs Drain Out The Lubricating Oil From Sump And Refilling After Proper Cleaning Of Sump. Replace Engine Oil Filter Cartridge With New One. Replace Fuel Filter Cartridge With New One. Check Tightness Of All Nuts And Bolts. Check Adjustment Of V Belt For Driving Engine Water Pump And Alternator. Cleaning Of Fuel Tank As Required Assembling Complete Old Serviceable Parts And Replacement Of Old Unserviceable Parts By New One As Per Direction Testing Of Dg Set After Servicing As Per Engineer In Charge. Cleaning Of Air Cleaner Filter And Renew After Period One Hundred Hrs Run Of Dg Set Or As Recommended By Engineer In Charge And Contractor Shall Be Responsible To Carry Out The Maint Servicing Where Require Time To Time And For Which No Extra Payment Shall Be Permitted. Any Parts Engine Oil Required To Be Replaced During Servicing Of Engine Shall Be Measured And Paid For Separately. , Supply Only Turbo Engine Oil 15W 40 - Supply Only Turbo Engine Oil 15W 40 Make Castrol Or As Per The Recommendation Of Kirloskar Greaves Cummins , Air Cleaner Filter Cartridge - Air Cleaner Filter Cartridge Make Of Dg Set Kirloskar Greaves Cummins Ruston Micco Fleet Guard

BOQ

Sl. No. Item TitleItem Description
1Supply Fixing and replacement of 11KV CT PTSupply Fixing and replacement of 11KV CT PT metering unit with ratio 30 5Amp frequency 50Hz no of CT three and No of PT three all complete as specified and directed
2Supply fixing and replcemnent of copper cable 6 SqmmSupply fixing and replcemnent of copper cable 6 Sqmm 4 core for connection of HT meter with CT PT all complete as specifiued and directed
3Supply fixing and replcemnent of copper cable 6 Sqmm 3 coreSupply fixing and replcemnent of copper cable 6 Sqmm 3 core for connection of HT meter with CT PT all complete as specifiued and directed
4Supply Fixing and Replacement of DG set StartSupply Fixing and Replacement of DG set Start manual on off panel suitable for 320 KVA DG set all complete as specified and directed
5Supply Fixing and Replacement of end termination lungsSupply Fixing and Replacement of end termination lungs for connection of CT and PT all complete as specified and directed
6Supply laying commissioning UG cable XLPE InsulatedSupply laying commissioning UG cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables Heavy duty 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core cable complete all as specified and directed
7Excavation in trenches not exceeding 1.5m wideExcavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete all as specified and directed
8Returning filling in including spreading levelling wateringReturning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard dense soil complete all as specified and directed
9Removing excavated material not exceeding 50mRemoving excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
10Material and labour for sand cushioning belowMaterial and labour for sand cushioning below and around cable in trenches with rever sand all as specified .
11Material and Labour for unreinforced precast concrete cableMaterial and Labour for unreinforced precast concrete cable cover class LV type 1 flat of size 250 x 150 x 40 mm for cable protection complete all as specified and as directed by EIC
12Supply and fixing GI tubing light grade 80 mmSupply and fixing GI tubing light grade 80 mm bore on poles under floors road crossing etc all as reqd at site and as directed by
13Material and Labour for Servicing overhauling of DG sets ofMaterial and Labour for Servicing overhauling of DG sets of capacity 63 kVA and 320 kVA including carrying out maintenance and check alongwith following repairs Drain out the lubricating oil from sump and refilling after proper cleaning of sump. Replace Engine Oil filter cartridge with New one. Replace fuel filter cartridge with New one. Check tightness of all nuts and bolts. Check adjustment of V belt for driving engine water pump and alternator. Cleaning of fuel tank as required Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction Testing of DG set after servicing as per Engineer in Charge. Cleaning of air cleaner filter and renew after period one hundred hrs run of DG Set or as recommended by Engineer in Charge and contractor shall be responsible to carry out the maint servicing where require time to time and for which no extra payment shall be permitted. Any parts Engine oil required to be replaced during servicing of engine shall be measured and paid for separately.
14Supply only Turbo engine oil 15W 40Supply only Turbo engine oil 15W 40 Make Castrol or as per the recommendation of Kirloskar Greaves Cummins
15Air cleaner filter CartridgeAir cleaner filter Cartridge Make of DG Set Kirloskar Greaves Cummins Ruston Micco Fleet Guard

AI Tender Summary

OUR REF NO 58481331
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 21-11-2026
Authority
Authority Name Indian Army
Work Description Bids Are invited for Supply Fixing And Replacement Of 11Kv Ct Pt - Supply Fixing And Replacement Of 11Kv Ct Pt Metering Unit With Ratio 30 5 Frequency 50Hz No Of Ct Three And No Of Pt Three All Complete As Specified And Directed , Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm - Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 4 Core For Connection Of Ht Meter With Ct Pt All Complete As Specifiued And Directed , Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 3 Core - Supply Fixing And Replcemnent Of Copper Cable 6 Sqmm 3 Core For Connection Of Ht Meter With Ct Pt All Complete As Specifiued And Directed , Supply Fixing And Replacement Of Dg Set Start - Supply Fixing And Replacement Of Dg Set Start Manual On Off Panel Suitable For 320 Kva Dg Set All Complete As Specified And Directed , Supply Fixing And Replacement Of End Termination Lungs - Supply Fixing And Replacement Of End Termination Lungs For Connection Of Ct And Pt All Complete As Specified And Directed , Supply Laying Commissioning Ug Cable Xlpe Insulated - Supply Laying Commissioning Ug Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Armoured Electric Power Cables Heavy Duty 1100 Volts Grade With Stranded Aluminium Conductor Of Size 50 Sq Mm 3.5 Core Cable Complete All As Specified And Directed , Excavation In Trenches Not Exceeding 1.5M Wide - Excavation In Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth And Getting Out In Any Type Of Soil For Laying Of Lt Ug Cables Complete All As Specified And Directed , Returning Filling In Including Spreading Levelling Watering - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Hard Dense Soil Complete All As Specified And Directed , Removing Excavated Material Not Exceeding 50M - Removing Excavated Material Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed , Material And Labour For Sand Cushioning Below - Material And Labour For Sand Cushioning Below And Around Cable In Trenches With Rever Sand All As Specified . , Material And Labour For Unreinforced Precast Concrete Cable - Material And Labour For Unreinforced Precast Concrete Cable Cover Class Lv Type 1 Flat Of Size 250 X 150 X 40 Mm For Cable Protection Complete All As Specified And As Directed By Eic , Supply And Fixing Gi Tubing Light Grade 80 Mm - Supply And Fixing Gi Tubing Light Grade 80 Mm Bore On Poles Under Floors Road Crossing Etc All As Reqd At Site And As Directed By , Material And Labour For Servicing Overhauling Of Dg Sets Of - Material And Labour For Servicing Overhauling Of Dg Sets Of Capacity 63 Kva And 320 Kva Including Carrying Out Maintenance And Check Alongwith Following Repairs Drain Out The Lubricating Oil From Sump And Refilling After Proper Cleaning Of Sump. Replace Engine Oil Filter Cartridge With New One. Replace Fuel Filter Cartridge With New One. Check Tightness Of All Nuts And Bolts. Check Adjustment Of V Belt For Driving Engine Water Pump And Alternator. Cleaning Of Fuel Tank As Required Assembling Complete Old Serviceable Parts And Replacement Of Old Unserviceable Parts By New One As Per Direction Testing Of Dg Set After Servicing As Per Engineer In Charge. Cleaning Of Air Cleaner Filter And Renew After Period One Hundred Hrs Run Of Dg Set Or As Recommended By Engineer In Charge And Contractor Shall Be Responsible To Carry Out The Maint Servicing Where Require Time To Time And For Which No Extra Payment Shall Be Permitted. Any Parts Engine Oil Required To Be Replaced During Servicing Of Engine Shall Be Measured And Paid For Separately. , Supply Only Turbo Engine Oil 15W 40 - Supply Only Turbo Engine Oil 15W 40 Make Castrol Or As Per The Recommendation Of Kirloskar Greaves Cummins , Air Cleaner Filter Cartridge - Air Cleaner Filter Cartridge Make Of Dg Set Kirloskar Greaves Cummins Ruston Micco Fleet Guard
Basic Detail
Tender No GEM/2026/B/8234265
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 11 Nov 2026
Submission Date 21 Nov 2026
Open Date 22 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
52e9aa28-d96f-40d0-b1f1-613c02ba73e7.pdf
bid_2026-11-03-14-44-53_ca1f23043bf0c990f309a0541f886d9d.pdf
10120250_Boq_1.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Nov 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
pdf

52e9aa28-d96f-40d0-b1f1-613c02ba73e7.pdf

pdf

bid_2026-11-03-14-44-53_ca1f23043bf0c990f309a0541f886d9d.pdf

xlsx

10120250_Boq_1.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender