Tender For Repair/Replacement Of Split/Window Ac, Refrigerator, Deep Freezer And Allied Works At Various Locs Under Aor Of Ge 969 Ews
Tender Value
15 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Split/Window Ac, Refrigerator, Deep Freezer And Allied Works At Various Locs Under Aor Of Ge 969 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for servicing/cleaning of complete indoor and outdoor unit of Split Type Air conditioner of AC 2.0 TR capacity/Window AC by means of adding cleaning solution with water, cleaning of the condensor and chiller tubes shall be clean with use of nylon brushes till the scaling is removed and ensuring its serviceability of rectification/ replacement of unserviceable parts and keeping AC in good working condition, complete all as specified and as directed. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch. |
| 2 | All as per serial item No. 1 above but split/ Window type AC 1.5 TR, complete all as specified and as directed. |
| 3 | M&L for taking out unserviceable compressor any type of Split Type AC 1.5 Ton capacity from site and replacement of compressor against repair of existing make and re-fixing the compressor sealed unit in position, charging of refrigerant gas R-22/410 of required quantity, bracing of discharge and suction line and leak testing, complete all as specified and as directed. |
| 4 | All as per Serial item No. 3 above but for Split Type AC 2 Ton Capacity, complete all as specified and as directed. |
| 5 | S&F in replacement PCB card for indoor unit of same model and make suitable for 1.5 TR Capacity Split AC/Inverter type Split AC units, complete all as specified and as directed. |
| 6 | All as per Serial item No. 5 above but for Split Type AC 2 Ton Capacity, complete all as specified and as directed. |
| 7 | S&F in replacement PCB card for outdoor unit of same model and make suitable for 1.5/2 TR Capacity split AC invertor type units, complete all as specified and as directed. |
| 8 | S&F in replacement fan motor for indoor unit of same model and make suitable for 1.5 TR capacity split type AC units, complete all as specified and as directed. |
| 9 | All as per Serial item No. 8 above but Split Type AC 2 Ton capacity, complete all as specified and as directed. |
| 10 | S&F in replacement outdoor motor AC/DC of same model and make suitable for 1.5/2 TR capacity, complete all as specified and as directed. |
| 11 | Supply and fix in replacement Fan Blower of indoor unit of split AC 1.5/2 TR, complete all as specified and as directed. |
| 12 | Dismantling old and unsv air swing fan motor and replacing with new one suitable for 1.5/2 ton capacity split AC, complete all as specified and as directed. |
| 13 | Dismantling old and unsv reverse valve and replacing with new one suitable for 1.5/2 ton capacity split AC, complete all as specified and as directed. |
| 14 | Dismantling old and unsv sensors and replacing with new one suitable for 1.5/2 ton capacity split AC, complete all as specified and as directed. |
| 15 | S&F in replacement of hard drawn copper pipe size suitable for existing one and connection with indoor to outdoor unit of AC plant along insulating rubber sleeves and including brazing, complete all as specified and as directed. |
| 16 | M&L for gas charging with R-22/410 for split type AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling appliances also). Complete all as specified and as directed. Note:- Gas leakage due to unserviceable of reverse valve and copper tube will be refilled by the contractor at his own cost. |
| 17 | S&F in replacement of Thermostate for Deep freezer/Refrigerator of size suitable for existing one, complete all as specified and as directed. |
| 18 | S&F in replacement of compressor for Deep Freezer of capacity 500 Ltrs, complete all as specified and as directed. |
| 19 | All as per Serial item No. 18 above but Deep freezer of capacity 400/300 Ltrs, complete all as specified and as directed. |
| 20 | S&F in replacement of compressor for Refrigerator with gas filling of any capacity, complete all as specified and as directed. |
| 21 | S&F in replacement of relay of suitable amp for Refrigerator/ deep freezer, complete all as specified and as directed. |
| 22 | Supply only remote control system of split/ window type AC of capacity 2/1.5 TR, complete all as specified and as directed. |
| 23 | Supply and fix Running capacitor 45/60 mfd for Split type Air conditioner 1.5 Ton Capacity, complete all as specified and as directed. |
| 24 | M&L Puff insulation to suction pipe of split AC, complete all as specified and as directed. |
| 25 | Supply and fixing in replacement copper wound Automatic voltage stabilizer, single phase naturally air-cooled indoor type & designed for input variation between 90V to 220V with output voltage stabilized upto 240V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and as directed. |
| 26 | Supply and fixing in replacement voltage stabilizer for Automatic operation, single phase naturally air-cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized upto 230V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and as directed. |
| 27 | Supply and fix in replacement plug top 15 Amp, complete all as specified and as directed. |
| 28 | Supply and fix in replacement plug top 5 Amp. |
| 29 | Supply and fix connecting cord 1.5 mtr length with plug top suitable for 1.5 Ton split/Window AC all as specified and as directed. |
| 30 | All as per Serial item No. 29 above but split/Window type AC 2 TR, complete all as specified and as directed. |
| 31 | M&L wiring kit suitable for windows type Acs of any capacity and make, complete all as specified and as directed. |
| 32 | M&L OLP for any type of AC/deep freezer/refrigerator of any capacity & make. |
| 33 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 100 LPD, complete all as specified and as directed. |
| 34 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 200 LPD, complete all as specified and as directed. |
| 35 | Suppy & fix in repair Flat Plate collector suitable for Solar Hot Water System based on indirect transfer of heat of capacity 300 LPD, complete all as specified and as directed. |
| 36 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 37 | M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed. |
| 38 | S&F switch piano Flush type, single pole16 amp 240 volts, complete all as specified and as directed. |
| 39 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 40 | S&F GI tubing 20mm medium grade, ISI Marked complete with all fittings and fixtures laid in trenches or laid under floors, fixed on walls with and providing clamps etc, complete all as specified and as directed. |
| 41 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, laying of cables, etc. and getting out in Hard/dense soil, complete all as specified and as directed. |
| 42 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm depth in soil, complete all as specified and as directed. |
| 43 | Removing excavated material (soil ) n.exc 50m and depositing where directed at a level n.exc. where directed at a level n.exc, complete all as specified and as directed. |
| 44 | S&F in repair Bib taps 20 mm Dia , cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed. |
| 45 | S&F in repair stop valves 20 mm , cast copper alloy screwd down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and as directed. |
| 46 | S&F in repair heating element of capcity 1.5KW (Round/Traingle), complete all as specified and as directed. |
| 47 | S&F in repair heating element of capcity 2KW (Round/Traingle), complete all as specified and as directed. |
| 48 | S&F in repair heating element of capcity 3KW suitable for 100/200/300 Ltr Solar Water Heater, complete all as specified and as directed. |
| 49 | Supply and fixing in repair thermostate suitable for 25/50 Ltr Geyser, complete all as specified and as directed. |
| 50 | Supply and fixing in repair thermostate suitable for 100/200/200 Ltr Solar Water Heatre Plant, complete all as specified and as directed. |
| 51 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete all as specified and as directed. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 52 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete all as specified and as directed. Note :- 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment. |
| 53 | Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc, complete all as specified and as directed. |
| 54 | S&F in repairs PVC connecting pipe 18\\" long with brass adopters for Hot/Cold water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe, complete all as specified and as directed. |
| 55 | S&F fusible plug melting at 90 - 100 degrees Centigrade including taking down existing uncerviceable fusible plug, complete all as specified and as directed. |
| 56 | S&F high pressure valve with dead weight suitable for 25 / 50 ltrs capacity Geysers including taking down existing unserviceable high pressure valve, complete all as specified and as directed. |
| 57 | S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25 / 35 / 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers, complete all as specified and as directed. |
| 58 | S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly, complete all as specified and as directed. |
| 59 | M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg / Sq.cm., re-assembling of any capacity Geysers, complete all as specified and as directed. |
| 60 | Note:- Schedule of credit Rs 65,295.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender