Tender For Repair And Renovation Of Antara Phc Building Under Khaira Block In The District Balasore Ama Hospital Inititatives (2Nd Phase) For The Year 2026-27 - 42/6775
Tender Value
65.85 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
4 days left
EMD
65855
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Renovation Of Antara Phc Building Under Khaira Block In The District Balasore Ama Hospital Inititatives (2Nd Phase) For The Year 2026-27 - 42/6775
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation in hard soil with dressing and levelling the bed and etc. Complete as per EIC |
| 2 | Providing and filling sand in foundation watering and ramming etc. Complete as per EIC. |
| 3 | Cement concrete (1:4:8) using 4cm size b.h.g metal etc. Complete as per EIC |
| 4 | Cement concrete (1:2:4) using 4cm size b.h.g metal etc. Complete as per EIC. |
| 5 | Brick work with Fly ash Brick of size 25cm x 12cm x 8cm having crushing strength not less than 75 Kg/cm2 with dimonsional C.M (1:6) in Foundation and plinth etc, complete. |
| 6 | Brick work with Fly ash Brick of size 25cm x 12cm x 8cm having crushing strength not less than 75 Kg/cm2 with dimonsional C.M (1:6) in Superstructure and plinth etc, complete. |
| 7 | 12 mm thick cement plaster with cement mortar (1:6) over brick wall outer surface of Brick wall after racking out joints, watering and curing etc complete. |
| 8 | 16mm thick cement plaster with (1:6) over Brick wall to interior surface of Brick wall after racking out joints, watering and curing etc complete |
| 9 | Supplying fitting and fixing of gypsum ceilling with alluminium anadised T section including cost of all labour etc complete. |
| 10 | Dismentaling cement concrete including cost of all labour etc complete |
| 11 | Dismentaling grading concrete on roof slab including cost of all labour etc complete |
| 12 | 4cm thick grading concrete on roof slab including cost of all labour etc complete. |
| 13 | Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M 30 grade made by block machin of approved size, design & shape and in required patter on road surfce including filling the interstics with sand etc complete. |
| 14 | Supplying fitting and fixing of Vitrified tile floor including cost of all labour etc complete. |
| 15 | Fixing of 10 mm thick Granite tiles in floors treads or stepps and landing on 25mm thick bed of Cement mortar 1:1 ( 1 Cement : 1 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. |
| 16 | Fixing of ceramic wall tiles in dados, skirting riser of stepps 20cmx30cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of tiles or stones. |
| 17 | Supplying Fitting and Fixing Chequerrd Tiles in Floors in Cement Mortar (1:4) including all complete as per EIC |
| 18 | Supplying fitrting fixing M.S door in windows & doors of approved design etc, complete. |
| 19 | Supplying fitting and fixing of flush door shutter including cost of all labour etc complete as per direction of Engg-in-charge. |
| 20 | Supplying fitting and fixing of Alluminium window including cost of all labour etc complete. |
| 21 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed. |
| 22 | Finishing wall surfaces with Acrylic wall putty (Water based) of approved make and finished smooth and even surfaces to receive painting including cost of all materials taxes, labour T&P etc. |
| 23 | Wall painting 2-coats with plastic emulsion paint over a coat of primer with any approved shade on new work to on ever shade including cost of all materials, labour T&P sundries etc. complete. |
| 24 | Finishing walls with two coat weather seal coat over a coat of primer of any approved shade with cost of all materials etc |
| 25 | Painting two coats over a coat of priming on new wood & iron work etc, complete. |
| 26 | Branding for HWC as per specification in outer plaster surface including all complete |
| 27 | Earth filling in hard soil including cost of all labour etc complete |
| 28 | Single under reamed pile foundation including cost of all labour etc complete. |
| 29 | R.C.C. work of M-20 using 20 mm and dowm graded cb. Chips with cost carriage of all materials etc. complete.Column Base |
| 30 | R.C.C. work of M-20 using 20 mm and dowm graded cb. Chips with cost carriage of all materials etc. complete.Grade Beam |
| 31 | R.C.C. work of M-20 using 20 mm and dowm graded cb. Chips with cost carriage of all materials etc. complete.Column |
| 32 | R.C.C. work of M-20 using 20 mm and dowm graded cb. Chips with cost carriage of all materials etc. complete.Roof Beam |
| 33 | R.C.C. work of M-20 using 20 mm and dowm graded cb. Chips with cost carriage of all materials etc. complete.Roof Slab |
| 34 | Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 35 | Fly ash Brick massonary in c.m. 1:6 having crushing strength 75kg/cm2 with cost carriage of all materials etc. |
| 36 | Fly ash Brick massonary in c.m. 1:6 having crushing strength 75kg/cm2 with cost carriage of all materials etc.Superstructure |
| 37 | Providing fitting and fixing stainless steel lettter with cost of all materials, taxes, labour etc. |
| 38 | Providing and Fixing of aluminum composite panel glazing fixed to wall surface of approved made and quality with ALSTRONG ACP 3mm thick mirror finish of exterior grade, the size of of outer aluminum square frameas 100x44 mm , inner aluminum square frame of 50x63 mm . Accessories such as stainless steel screw, VHP tape, 789 grade silicon, coir etc. complete including cost, conveyance, taxes of all materials, labours, cerntring & shuttering charges etc complete.The section are to be cut to length, meter joint with croner bracket & frame are fixed to the concrete/ masonary wall by means of self expanding screws etc. complete. |
| 39 | Supplying fitting and fixing of Blue Scope fibre sheet including cost of all labour etc complete. |
| 40 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum.F.F Column |
| 41 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum.Roof Beam |
| 42 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum.Roof Slab |
| 43 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum.Lintel |
| 44 | RCC work of M-20 grade with 20mm & down-grade size black hard granite(crusher broken) chips including hoisting&laying.(Data for 15 cum.Chajja |
| 45 | A/R-P 52/item No.9:Supplying, fitting and placing un-coated HYSD bar reinforcement complete as per drawing and technical specification(1st floor) |
| 46 | A/R-P 71/item No.3:Brick work with fly Ash Bricks having crushing strength between 100kg/cm2 to 149kg/cm2 in Cement mortar(1:6) in superstructure including cost of all labour etc complete.(1st floor) |
| 47 | Supplying fitting and fixing of vetrified tile floor including cost of all labour etc complete |
| 48 | Fixing of ceramic wall tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles or stones. |
| 49 | A/R-P 109/item No.26:6mm thick Cement plaster (1:4) finished smooth per 1 Sqm. including curing etc. complete. |
| 50 | A/R-P 105/item No.14:16mm thick Cement plaster (1:6) over brickwork including curing etc. complete.(1st floor) |
| 51 | 12mm thick Cement plaster (1:6) for brickwork including curing etc. complete.(1st floor) |
| 52 | Wall painting 2-coats with plastic emulsion paint over a coat of primer with any approved shade on new work to on ever shade including cost of all materials, labour T&P sundries etc. complete.(1st floor) |
| 53 | Finishing walls with weather coat over a coat of primer approved shade on new work excluding cost of paint.(1st floor) |
| 54 | Painting two coats over a coat of priming on new wood & iron work etc, complete. |
| 55 | A/R-P 132/item No.2:Dressed seasoned Nonsalwood work framed and fixed in trusses,purlins, door, window, ventilaters and beams. |
| 56 | E.I.Re- wiring to light point ,Ex haust Fan point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/KEI/Polycab/Gloster) (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) -do- Group A(1.17.1) |
| 57 | -do- Group B(1.17.2) |
| 58 | -do- Group C(1.17.3) |
| 59 | Recessed wiring to Fan Point in... -do- Group C(1.17.3) |
| 60 | S/F of Angle holder replacing Ceilling Rose (Make : Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 61 | S/F of 5A. Switch & 5A. Socket outlet of ISI marked on existing board (Make of Switch & Socket: Anchor / Cona/ Greatwhite/ Havells/ HPL/ Preeti) |
| 62 | S/Fof metal box of 150 mm x 75mm x 60mmdeep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amp. Socket out let 5/6amp. Piano type switch,connection,painting etc. as required (1.26) |
| 63 | S/F of metal box of 180mm x 100mmx60mm deep (Nonunal size) in recess with suitable size of Phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amp. Socket out let 15/16 amp. Piano type switch,connection, painting etc. as required(1.27) |
| 64 | S/F of Computer board consisting of 3 nos. of 5 amp switch and Socket and 6 amp MCB complete with wiring on (200mmx250x75mm)deep M.S.box with B.k.cover(1.24.9 + 1.25.1+ 1.25.4 +197~) |
| 65 | S/F of Power point with (180mmx100mmx60mm)& (100mmx100mmx60mm) deep M.S box with B.K cover in recess including providing and fixing of 3 pin 15/16 amp. piano type switch & Socket & Mini DP MCB, connection, painting etc as required for AC |
| 66 | S/F to 16/18 SWG metal box of following sizes (normal sixe) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. -do-100 mm x 100 mm x 60mm deep(1.24.2) |
| 67 | ..do -150 X 150 X 60 mm deep (1.24.4) |
| 68 | -do-180mmx100mmx60mm deep(1.24.5) |
| 69 | -do-200mmx150mmx60mm deep(1.24.7) |
| 70 | Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire: Finolex/ L&T / Anchor / Havels /HPL / V Guard/ KEI/ Greatwhite/ Polycab)2x1.5+1x1.5 (1.19.2+1.19.1) |
| 71 | 2x2.5+1x1.5 (1.19.11+1.19.1)) |
| 72 | 2x6+1x2.5 (1.8.4) |
| 73 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 74 | S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1) (Make : Legrand/ LK/SCHNEIDER/C&S/ABB/SIEMENS) |
| 75 | Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31) |
| 76 | S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections ( Make- Crompton/ HPL/ Polycab/ Havells/Orient / Panasonic/ RR/K-lite ) |
| 77 | SITC of 1200mm Sweep A.C Ceiling fan (1 star) Copper Winding with Aluminium Blades having Air Deleivery - 225m3/min with out fan regulator (Make:Usha-Striker neo HS/Crompton- HS/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White - Aldous/ Pollycab - Vital HS ) including wiring,the down rod of standard length (up to 30cm) with 1.5 sq mm PVC insulated single core Multistrand copper conductor etc. as required as per direction of Engineer-in-Charge,(Replacement warranty will be 2 years) |
| 78 | S/F step type modular fan regulator |
| 79 | Supply and fixing of 45-48 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections (Make- Crompton/ Phillips/ HPL/ Polycab/ Havells/ Panasonic/ RR/ Orient/K-Lite ) |
| 80 | S/F of 1.5T 3Star Inverter model split type AC Machine, (Make-Carrier/Hitachi/Bluestar/LG/Mistubishi/O-General/Daikin) |
| 81 | S/F of 2000 VA/24V Inverter with 2 nos. 180Ah battery including trolley arrangement (Make: V-Guard/ Microtake/ Luminous) |
| 82 | S/F of 4KVA Automatic Voltage Stabilizer(110-300V), (Make-Microtech/V-Guard) |
| 83 | S/F of 5/6F.T.Switch (1.25.1) |
| 84 | S/F of 15/16F.T.Switch (1.25.2) |
| 85 | S/F of3 pin 5/6F.T.Socket (1.25.4) |
| 86 | S/F of 6 pin 15/16F.T.Socket (1.25.5) |
| 87 | PHSupplying all materials, labour T&P and dismantling the damaged squatting type water closet and urinal plates etc. and mending good the damages to the floor and removing the debris at a safe distance as per direction of E.I.C. |
| 88 | Supplying all materials, labour T&P and dismantling the damaged EWC and mending good the damages to the floor and removing the debris at a safe distance as per direction of E.I.C. |
| 89 | Supplying all labour, T&P and dismantling and removing old tile flooring including removing the base course and stacking the useful materials for reuse and removing the debris within 50m lead. |
| 90 | Supplying all labour, T&P, and dismantling and removing old tile cladding from wall including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m intial lead. |
| 91 | Supplying all materials, labour T&P and fixing Ceramic Tiles in floors on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per specification and direction of EIC- Ground Floor |
| 92 | Supplying all materials, labour T&P and fixing porcelain glazed tiles in dados skirting, on 12mm thick C.P. (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of Engineer-in-Charge.[Gr. Floor] |
| 93 | Supplying all materials, labour T&P and fixing Water closet, (Orissa pattern squating pan) duly embeded in C.C. (1:5:10) using 4cm h.g. metal all complete as per direction of E.I.C.- 580mm Orissa pan (Cerra/Parry ware/ Hindware) |
| 94 | Supplying all materials, labour T&P and fixing Wash Down Water Closet(European type W.C. pan) with Integral S or P trap to the floor with wooden plug and C.P.screws including jointing the trap with soil pipe in C.M.(1:1) etc. all complete as per specification & direction of E.I.C-- E.W.C. with S trap Plain(Cerra/ Parry ware/ Hindware) |
| 95 | Supplying all materials, labour, T&P fitting and fixing Plastic Seat and cover for E.W.C. with chromium plated brass hinges and rubber buffers all complete as perr specification and direction of E.I.C. (Cerra/Parry ware/ Hindware) |
| 96 | Supplying all materials, labour T&P and fitting & fixing SWR ventilating pipes and fittings of the following O.D conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturers specification, testing, e.w. in excavation in all kinds of soil and refilling of trenches as per direction of E.I.C.- 110 mm dia PVCSWR Pipes |
| 97 | 110 mm dia PVC SWR P Trap |
| 98 | 110 mm dia PVC SWR Door Cross Tee |
| 99 | 110 mm dia PVC SWR Door Tee |
| 100 | 110 mm dia PVC SWR Door Bend |
| 101 | 110 mm dia PVC SWR Plain Bend |
| 102 | 110 mm dia PVC SWR Cowl |
| 103 | 125 mm dia C.P.grating |
| 104 | 75 mm dia SWR Pipes |
| 105 | 75 mm dia PVC SWR Plain bend |
| 106 | 75 mm dia PVC SWR Door bend |
| 107 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with C.I/M.S brackets painted white including holes in walls and making good the damages etc. all complete as per P.H specification and direction of E.I.C.-- 550mm x 400mm WHB with all Fittings with C.P. Waste, PVC Waste Pipe & Connection Pipe. (Cera/ Parry ware/ Hindware) |
| 108 | Supplying all materials, labour T&P and fixing padestrial for wash basin complete recessed at the back for the reception of pipe and fitting etc. all complete as per specification and direction of E.I.C. (Parrywear/Cera/Hindware) |
| 109 | Supplying all materials, labour T&P and fixing mirror of superior glass mounted on 6mm thick plywood sheet and fixed to wooden plugs with C.P screws and washers complete as per P.H specification and direction of E.I.C.-- 600mm x 450mm B.E. Mirror (fixed type) |
| 110 | Supplying all materials, labour T&P and fixing standard size C.P. towel rail / ring complete with c.p. brass brackets fixed to wooden plugs with c.p screws as per P.H specification and direction of E.I.C. -- 20 mm x 600 mm long C.P Towel rail |
| 111 | C.P. Towel Ring (St.) |
| 112 | Supplying all materials, labour T&P and fixing standard size C.P. soap holder complete with c.p brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of E.I.C C.P.Soap Holder. |
| 113 | Supplying all , labour T&P and fitting, fixing of standard size Glass shelf with CP brass bracket and guard rails complete fixed to wooden plugs with CP screw as per specification and direction of E.I.C -- 450x125mm size Plate Acrylic Shelf |
| 114 | Supplying all materials, labour T&P and fixing bowl pattern urinal including the connecting the urinal with waste pipe by means of white lead list with chopped hemp etc. all complete as per direction of E.I.C.-- Flat back lipped wall urinal (standing Urinal) including 32mm dia PVC Waste Pipe with brass coupling nut & 15mm dia PVC inlet connection Pipe[CerraParrywear/Hindware] |
| 115 | Supplying all materials, labour, T&P and cleaning the liquid sludge etc. all complete and disposing them outside as per direction of E.I.C-liquid Sludge |
| 116 | Supplying all labour, T&P and dismantling and removing damaged RCC Slab of S.T. including stacking the useful materials for reuse on removing the debrises within 50m lead as per direction of E.I.C. |
| 117 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks 25cmx12cmx8cm size having cs. not less than 75kg / cm2 with dimensional tolerance ± 8% in including watering,curing conveyance of all materials to worksite, payment of royalty taxes etc. all complete as per specification and direction of EIC. - In Foundation & Plinth in CM (1:4) |
| 118 | Supplying all materials, labour, T &P and providing C.C (1:1.5 :3 ) using 12mm h.g. chips for R.C.C. works including hoisting, laying, watering, curing, conveyance of all materials to worksite, curing, conveyance of all materials to worksite, payment of royalty, taxes etc, all complete as per specification and direction of E.I.C. |
| 119 | Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite etc. complete as per directio n of E.I.C. |
| 120 | Supplying all materials, labour, T&P and providing rigid & smooth centering & shuttering for R.C.C.works including false work and dismantling them after casting including conveyance of all material, to worksite, payment of royalty, taxes etc. all complete as per direction of E..I.C.-- R.C.C.Slab |
| 121 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of E.I.C.-- 12mm thick C.P with C.M. (1:4) |
| 122 | 20mm thick C.P with C.M. (1:4) |
| 123 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per specification and direction of E.I.C. |
| 124 | Supplying all labour, materials T&P and fixing of R.C.C. Baffle wall pre-cast with C.C. (1:1.5:3) using 12 mm b.h.g. chips and fitted to septic tank as per P.H. Specification and direction of E.I.C. |
| 125 | Supply all materials ,labour,T&P providing fitting and fixing PVC. Tee in wall including filling the necessary with cement concrete (1:2:4) with 12mm size h.g. chips all complete including watering curring,conveyance of all \\"materials to work site .payment of royality .taxes its all complete as per specification and direction of E.I.C.-11OmmXI 10mm X110mm PVC Tee |
| 126 | Supplying all materials labour T& P and providing 500 x 500 x 100mm thick RCC precast M.H cover in C.C (1:1.5:3) using 12mm h.g. chips and placing the cover on the MH/S tank & finishing smooth all complete as per specification and direction of E.I.C |
| 127 | Supplying all materials, labour T&P and Repairing of damaged Inspection Chamber /with moulding and shaping the channel inside and benching with c.c. (1:11/2:3) using 12mm size h.g. chips 12mm thick c.p. (1:3) with punning to inside, R.C.C. cover slab in c.c. (1:11/2:3) using 12 mm size h.g. chips with R.C.C. m.h. cover including watering, curing, conveyance of all materials to site payment of royalty, taxes etc. all complete as per approved specification and direction of the E.I.C. Inspection chamber |
| 128 | Supplying all materials, labour, T&P and laying 110 mm dia SWR pipes of the following O.D conforming to IS No. 13592 and aligning to requisite gradient inside the trench encasing all round of the pipe with c.c (1:3:6) using 4 CM size h.g. metal and CC(1:3:6) with 4CM size h.g. metal in the bed of the trench including lowering the pipes to the bed of the trench, earth excavation in trenches in all kinds of soil, refilling the same in layer of 0.3 mtrs with watering and ramming, removing of surplus earth, testing of sewerage line including use of T&P as per PH Specification and direction of E.I.C.- 110 mm dia SWR Pipe Sewerage line with all round encasing (conforming to IS No. 13592) |
| 129 | Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.- 1.20mtrs.dia x 2.0mtr.deep soak way pit |
| 130 | Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.- 1.40mtrs.dia x 2.0mtr.deep soak way pit |
| 131 | Supplying all materials, labour T&P and filling in F&P with Coarse sand including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 132 | Supplying all materials, labour T&P and filling in F&P with 6mm thick metal including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 133 | Supplying all materials, labour T&P and filling in F&P with 20-25mm thick metal including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 134 | Supplying all materials, labour T&P and filling in F&P with 25-40mm thick metal including conveyance of all materials to worksite payment of royalty, taxes etc. all complete as per direction of E.I.C. |
| 135 | Supplying all materials, labour, T&P and fitting water container -2 nos (25 lit & 5 Lit BPA Free) for Liquid Waste treatment including providing 20mm dia & 25mm dia & 32mm dia PVC PIipe, fixing 20mm dia & 32mm dia U-PVC Ball valve including hoisting and placing in position including supplyh of Iron bracket with jally with painting the iron works,including cost of all materials, conveyance & taxes to work site involves managing and treating liquid waste generated from various medical procedures, patient care and labortaory testing to prevent contamination and to ensure safe disposal fixing etc. all complete as per direction of EIC. |
| 136 | Supplying all materials, labour T&P and constructing soak way pit of the following sizes with dry brick walling form bottom up to invert of inlet pipe and 1st class Fly Ash brickwork in c.m(1:6) for the remaining height at top, 12 mm thick c.p(1:4) inside and outside over masonary brickwork gravel packing in the rear of well steining R.C.C. cover slab in c.c (1:11/2:3) using 12mm size h.g. chips fitted with iron lifting handles including e.w. in open well excavation in stoney earth and refilling the cavity around the pit & painting the iron works, watering , curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of E.I.C.- 0.90mtrs.dia x 2.0mtr.deep soak way pit |
| 137 | Supplying all materials, labour, T&P and fixing rotational moulded polyethylene cylindrical vertical waterstorage tank confirming to IS 12701- 1996 including cutting hole through the tank and fixing MS tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting the tank and placing the tank to the required position including all complete as per specification and direction of EIC.(including cost of FG Over Head Tank) -- 1000 Ltrs. Capacity F.G.Over Head Tank. (on roof of Gr. floor) |
| 138 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor PVC Pipes conforming to ASTM-D-1785/89(sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and direction of E.I.C - 20 mm dia PVC (ASTM) Pipe [Internal] |
| 139 | 25 mm dia PVC (ASTM) Pipe [Internal] |
| 140 | 25 mm dia PVC (ASTM) Pipe) [External] |
| 141 | 32 mm dia PVC (ASTM) Pipe) [External] |
| 142 | 25 mm dia HDPE Pipe [External Including E/W] |
| 143 | Supplying all materials,labourT&P and cutting holes through brick/stone masonary walls for taking water supply pipes and fittings including making good the damages etc.all complete as per P.H specification and direction of Engineer in charge |
| 144 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. . |
| 145 | Supplying ail materials,labour,T&P and fitting & fixing brass/C.P fittings of the following nominal bore with supply of all jointing materials etc. complete as per P.H specification and direction of E.I.C.- 15mm dia. C.P Bibcock (Short body) [Jaquar] |
| 146 | 15mm dia. C.P Bibcock (long body) [Jaquar] |
| 147 | 20mm dia.C.P Conceal stopcock [Jaquar ] |
| 148 | 15mm dia.C.P Angle stopcock[[Jaquar ] |
| 149 | 15mm dia C.P Pillar cock [Jaquar ] |
| 150 | 15mm CP Two Way Bib cock[[Jaquar] |
| 151 | 15mm dia C.P. Health Faucet [Jaquar ] |
| 152 | 15mm dia C.P. Elbow Action Bib Cock [Jaquar ] |
| 153 | 15mm dia C.P Flange |
| 154 | 15mm dia C.P Extension piece. |
| 155 | 25mm dia. PVC Ball valve [Metal Ball] |
| 156 | 32mm dia. PVC Ball valve [Metal Ball] |
| 157 | 15mm dia PVC Connection Pipe |
| 158 | 32mm dia. PVC Waste Pipe |
| 159 | 32mm dia. C.P. Waste |
| 160 | Supplying all materials, labour, T&P and fitting and fixing C.P. shower with 15 mm or 20 mm inlet with C. P. shower arm including polishing all complete as per P.H. specification and direction of E.I.C. |
| 161 | Supplying all materials, labour T&P and fitting & fixing 10 Litres capacity low level cistern with a pair of cast iron of m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipe. 32 mm C.P flush bend 15mm PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of E.I.C (Cerra/ Parry ware/ Hindware) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender