Tender For Construction Of Sub-Register Office Building At Derabish Block For The Year-2025-26 In The District Of Kendrapara
Tender Value
1.08 Crore
Estimated cost
Bid Submission
27 Nov 2026
4 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kendrapara → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Sub-Register Office Building At Derabish Block For The Year-2025-26 In The District Of Kendrapara
BOQ
| Sl. No. | Item Description |
| 1 | 500 mm dia cast in situ pile foundation in all kinds of soil to a depth of 10.0mt. from original ground level with RCC M30 using 20mm down graded size black hard granite (crusher broken) stone chips including cost of boaring and cost of all material, labour, T&P etc. all complete but excluding cost of M.S/ Tor steel & labour charges for cutting, bending and binding of steel and as per the direction of the Engineer- in-charge . |
| 2 | Earth work in excavation of foundation trenches in all kinds of soil including dressing and leveling the bed upto the required depth and depositing the excavated materials with all leads and lifts T&P shoring & Shuttering if required etc.complete as directed by the Engineer-in-charge. |
| 3 | Supplying filling in foundation and plinth with sand including watering ramming, cost, conveyance, royalties and all taxes of materials and cost of labour with T&P required for the work etc. complete(measurement will be taken on finished section only etc.complete as directed by the Engineer-in-charge. |
| 4 | Providing Cement concrete (1:3:6 ) using 40mm. size hard crusher broken grinite metal of approved quality from approved quarry in foundation and plinth including hoisting , lowering , laying in layers not exceeding 0.15mt. in thick , compacting , water curing with all cost, carriage, royalty, all taxes, labour & T. & P. etc. complete as per specification and direction of E.I.C. |
| 5 | Fly Ash brick ,masonary in cement mortar (1:6) in F&P using flyash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75kg/cm2 including splays cutting circular moulding chamfering and corbelling watering and curing after immersing the bricks in water for six hours before use etc., complete, including cost and conveyance of all materials and labour required for the work with all taxes and royalties etc. with all T&P complete in all respect as per specification and direction of the Engineer-in-Charge. |
| 6 | Cement Concrete (1:2:4) with 12mm size hard granite chips for RCC works includimg hoisting and laying etc complete as per direction of the engineer-in -charge. |
| 7 | RCC wok of M-30 grade with 20mm downgraded size hard granite chips including hoisting and laying and compacting concrete by using vibrator with watering and curing for 28 days, centering and shuttering and finishing the exposed surface smooth providing grooves or beads where ever necessay including cost, conveyance, royalties and taxes of all materials and cost of all labour with T&P required for the work etc. complete in all respect but excluding cost of M.S.Rods or Tor Steel and binding wires and labour charge for bending binding and tying the grills etc.complete in all respect as as per the specification and direction of the Engineer-in-charge.(A) Pile Cap |
| 8 | B) In Plinth Beam |
| 9 | C) Column :In Super Structure |
| 10 | (F) Lintel |
| 11 | (G)Chajja |
| 12 | (E) Roof Beam |
| 13 | (E) Roof Slab |
| 14 | Providing HYSD bar reinforcement for R.C.C. work including Straightening, cutting, bending, binding, welding, tying the grills, laying and placing in proper position as per approved design and drawing including cost, conveyance of 18 to 20 gauge binding wire cost and conveyance of HYSD bars complete in all respect as per specification for road & Bridge and direction of Eng - in Charge. |
| 15 | Fly Ash brick ,masonary in cement mortar (1:6) in Super structure using flyash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75kg/cm2 including splays cutting circular moulding chamfering and corbelling watering and curing after immersing the bricks in water for six hours before use etc., complete, including cost and conveyance of all materials and labour required for the work with all taxes and royalties etc. with all T&P complete in all respect as per specification and direction of the Engineer-in-Charge. |
| 16 | 1st Floor Parapet Wall |
| 17 | Fly Ash brick ,masonary in cement mortar (1:6) in Super structure using flyash bricks of 25cmx12cmx8cm size having a crushing strength of not less than 75kg/cm2 including splays cutting circular moulding chamfering and corbelling watering and curing after immersing the bricks in water for six hours before use etc., complete, including cost and conveyance of all materials and labour required for the work with all taxes and royalties etc. with all T&P complete in all respect as per specification and direction of the Engineer-in-Charge. |
| 18 | 12mm(1/2\\") thick cement plaster (1:6)in finished smooth to outside smooth surface of brick walls afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. Ground Floor |
| 19 | 1st Floor Parapet Wall |
| 20 | 16mm(5/8\\") thick cement plaster (1:6)in finished smooth to inside smooth surface of brick walls afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. |
| 21 | 6 mm thick cement plaster (1:4) to R.C.C surface finished smooth including deep chiping and slurt treatment etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. |
| 22 | Supplying, fitting and fixing Kota stone tile 0.1 sqm to 0.40sqm of 10 mm thick in floors of approved make confirming to IS : 13755 laid on 20mm thick cement mortar (1:4) & filling the joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.)etc. with cost conveyance royalties and taxes of all materials and cost of all labour and T&P required for the work etc. complete as per the direction of the Engineer-in-charge |
| 23 | Fixing Kota tiles in dados skirting and risers of step on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete with cost conveyance royalties and taxes of all materials and cost of all labour and T&P required for the work etc. complete as per the direction of the Engineer-in-charge |
| 24 | Supplying, fitting and fixing of Anti Skid ceramic floor tile in floors of approved make laid on 20mm thick cement mortar (1:4) & filling the joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.)etc. with cost conveyance royalties and taxes of all materials and cost of all labour and T&P required for the work etc. complete as per the direction of the Engineer-in-charge |
| 25 | Fixing tiles & Glazed /Ceramic in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete excluding cost of precast tiles. per 1 sqm (Data for 10 sq.mt.) etc. with cost conveyance royalties and taxes of all materials and cost of all labour and T&P required for the work etc. complete as per the direction of the Engineer-in-charge |
| 26 | Finishing surface of wall with cement based wall putty (Water Based) of approved make & finished smooth and even surface to receive painting including cost of all materials etc. complete as per the specification and direction of the Engineer-in-charge |
| 27 | Wall painting two coats over one coat of primer with weather coat of approved shade on wall surface including cost of weather coat and all materials labour T & P etc complete as per direction of the Engineer-in-Charge. |
| 28 | Distempering two coat over one coat of primer including cost of distemper & primer, cost conveyance and all taxes of all materials and labor with T&P required for the work etc.complete in all respect etc. complete as per direction of Engineer in charge. |
| 29 | Supplying , fitting & fixing of M S Grill & gate Iron Doors and windows perpor position including all cost carriage of all materials etc.complete in all respect as per specification and direction of the Engineer-in- charge |
| 30 | Painting two coats in all floors to new wood and iron work over a coat of primer including sand papering,polishing the surface,including cost conveyance royalties and all taxes of all materials alongwith T&P required for the work including cost of paint & primer complete in all respect as per the direction of Engineer in Charge. |
| 31 | Supplying fitting and fixing of stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick Circular pipe with balustrade of size 32mm X 32mm X 2mm @ 0.90mtr C/C and stainless squre pipe bracing of size 32mm X 32mm X 2mm in three in staire case as per approved designand specification , buffing ,polishing etc with cost , conveyance taxes of all materials labour T&P etc required for the complete in all respect |
| 32 | Supplying and fixing 46mm size thick GI Doors and frame conforming to IS 277 galvanised plain skin passed sheets of 0.80mm in shutter & 1.20mm in frame with minimum 120 GSM zinc coating with profile dimension of 100mm x 58mm frame filled with polyurethane frame and shutter duly filled with Honeycomb and both coated with minimum 60 microns of RAL / wood finish powder coating accessories will be provided with doors etc complete. (TATA Pravesh brand). |
| 33 | Al Door sec 9202 as vertical member,sec no 9201 as top member 9200 as bottom &middle member with frame section as 9221 with tappered clip no 4660 jointing angle no 1855 with prelaminated board & black glass (Data for 3'-0\\"X6'-6\\")=19.50 Sqm or 1.81 Sqm |
| 34 | Supplying & fixing GI Window (IS 513 D quality) and frame conforming to IS 277 galvanised plain skin passed sheets of 0.6mm in shutter & 0.8mm in frame with minimum 120 GSM zinc coating and fitted with acryllic sheet of 4mm thickness & MS Grill of 10mm square MS bright bars coated with zinc phosphate primer or thermos etting Polyurethane paint of aliphatic grade providing high level of scratch resistance and durability accessories will be provided with windows etc complete. (TATA Pravesh brand). |
| 35 | Supplying, fitting and fixing of 30mm thick P.V.C. shutter having shutter panel made from infil consisting of hollow rigid PVC extruded section having dimension of 200 x 20mm and joined with one another by sliding locking system. The shutter frame shall be made from rigid PVC multicavity hollow chamber a type extruded section in an over all dimension of 30 x 59mm (Tolerance+ 1mm). Four corners of the shutter jointed with one another by steel screw after insetting 4 Nos solid plastic L-shaped brackets or MS recatangular tubular galvanized and then 2 nos of bright steel rods of 6mm diameter shal be inserted horizontally through stiles and panels with 2 nos of check nuts and washers with PVC door frame made from extruded PVC multi-chamber hollow section having dimensions of 48mm x 40mm (Tolerance + 1mm) with wall thickness 2.0mm + 0.2mm. Horizontal and vertical section shall be joined by steel screw after inserting M.S. tubular rectangular galvanized L-shaped or solid plastic brackets of size 200mm x 75mm with metred cut at the coners. Hinges side of the frame shall be reinforced with M.S. tubular section of size 19mm x 19mm and 1mm + 0.1mm. |
| 36 | Providing Fitting and Fixing of Plain Glass of 6mm thick in Ventilators including all cost of nails and putty for fixing of glass pans in proper position etc complete and as per the direction of engineer in charge. |
| 37 | 2.5 cm cement concrete ( 1 : 2 : 2 ) using 6 mm size HG chips on roof slab watering , curring, etc complete including side shuttering, cost, conveynance ,taxes and royalty of all materials & labour T & P required on the work etc complete in all respect. direction of the Engineer-in-charge. |
| 38 | EI Wowk Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) -do- Group A |
| 39 | -do- Group B |
| 40 | -do- Group C |
| 41 | -do- Group B Recessed wiring to Fan Point in... |
| 42 | -do- Group C |
| 43 | -do- Group B Recessed wiring to Call Bell Point in |
| 44 | Recessed wiring to Exhaust Fan Point in -do- Group B |
| 45 | S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof. |
| 46 | S/F of Angle holder replacing Ceilling Rose |
| 47 | Swich BoardsS/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board |
| 48 | S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp modular switch, connection, painting etc as required. |
| 49 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. Modular switch & Socket, connection, painting etc as required |
| 50 | S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover. |
| 51 | S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection |
| 52 | S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover |
| 53 | 4 Modular box with base & cover |
| 54 | 6 Modular box with base & cover |
| 55 | 8 Modular box with base & cover |
| 56 | 12 Modular box with base & cover |
| 57 | Sub-MainWiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1) |
| 58 | 2x2.5+1x1.5 (1.8.2) |
| 59 | 2x4+1x1.5 (1.8.3) |
| 60 | 2x6+1x2.5 (1.8.4) |
| 61 | 2x10+1x4 (1.8.5) |
| 62 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 63 | Circuit Breakers S/F of 'C' series SP MCB of 10A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 64 | S/F of 'C' series DP MCB of 16 amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 65 | S/F of 'C' series DP MCB of 63Amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 66 | S/F of 8 Way SPN Double Door Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 67 | S/F of 12 Way SPN Double Door Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box (Make : Legrand / Hager / Scheider / Seimens) |
| 68 | EarthingEarthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2) |
| 69 | Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18) |
| 70 | FittingsSupply and fixing of 230mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 9\\" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delus R/Orient-Power Flow DBB// Pollycab -Fresh on DBB ) |
| 71 | S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections (Make:HPL/ Havells/PAC/Crompton/Polycab / Klite / Panasonic) |
| 72 | Supply and fixing of 1200mm A.C. Ceiling fan (1 star) with all accessories and connections with out fan regulator (Make:Usha-Striker neo HS/Crompton- Highspeed/Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White - Aldous/ Pollycab - Vital HS ) |
| 73 | S/F step type modular fan regulator |
| 74 | Supply & fixing of superior type Led bulk head fitting general domestic use ISI marked square / oval type including necessary connections. ( M-5 ) |
| 75 | Supply and fixing of 45-48 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections ( Make- Crompton /Phillips /HPL /Polycab /Havells / Klite / Panasonic ) |
| 76 | Supply and fixing of 60 Watt Single LED Street Light Fitting with LED & Electronic driver with all accessories and connections ( Make- Crompton/Phillips/HPL/Polycab/Havells / Klite / Panasonic ) |
| 77 | S/F of 10w Watt LED Bulb ( Make- Crompton/Phillips/HPL/Polycab/Havells / Klite / Panasonic ) |
| 78 | S/F of 2300VA/24V Invertor machine with 2 nos 180Ah tall tubular Battery including Trolly (Make-Luminous /microtek/v-guard) |
| 79 | S/F of 24W LeD Ceiling or surface Panel light (Havels/crompton/philips/panasonic) |
| 80 | S/F of 15A socket on 2Modular Board board for A.C |
| 81 | S/F of 25A Moter Starter switch for A.C (Make: Havells / Anchor/Le-Grand) |
| 82 | CablesProvision of Aluminium Armoured cable size 4x16sqmm Make- (Polycab/KEI/Havells) |
| 83 | Laying of MV cable upto 25sqmm on surface (5.5.1) |
| 84 | S/F of 40mm HDPE pipe for laying of cable & protection. |
| 85 | PanelsSupply & fixing of 63A DP Panel board (18*18*8mm with 16CR sheet Powder coated )1. 63A 2P MCB (Make : Legrand / Hager / Scheider / Seimens)-1no 2.16A 2P MCB (Make : Legrand / Hager / Scheider / Seimens)-2no3. 63Amp Copper Bus-bar 25*5mm -1set4. 32A Single phase change over -1Nos..5. Indicating Lamp and 63Amp Heavy duty DP PVC Connector-1No. 6. All accesories & Connection (Rating & Danger borad) |
| 86 | PH Works Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. 110mm diameter U-PVC SWR pipes |
| 87 | 110mm U-PVC P-trap |
| 88 | 110mm U-PVC Single junction door |
| 89 | 110mm U-PVC Double junction door |
| 90 | 110mm U-PVC door bend |
| 91 | 110mm U-PVC Offset |
| 92 | 110mm U-PVC plain bend |
| 93 | 110mm U-PVC vent cowl |
| 94 | 125 mm dia C.P Grating |
| 95 | 75mm diameter U-PVC pipes |
| 96 | 75mm U-PVC Plain bend |
| 97 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in floors, on 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C.a) Ground Floor |
| 98 | b) 1st Floor |
| 99 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados/skirtings on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing etc. all complete as per direction of the E.I.C.a) Ground Floor |
| 100 | b) 1st Floor |
| 101 | supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking HCI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.375 mm thick wall |
| 102 | 250 mm thick wall |
| 103 | Supplying all materials, labour, T&P and laying in trenches U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and providing bed concrete in P:C:C (1:4:8) using 40 mm size metal and haunch top the pipe with refilling of trenches etc all complete as per P.H specification and direction of the E.I.C.110 mm dia PVC Pipe all round |
| 104 | 160 mm dia PVC Pipe all round |
| 105 | Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) & PVC Seat cover etc all complete as per specification and direction of the E.I.C.EWC with Seat Cover(Hindware/Parryware) |
| 106 | Supplying all materials, labour, T&P and Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C |
| 107 | Supplying all materials, labour, T&P and fixing the Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 108 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C. (a) Inside size 760mm x 760mm x 460mm |
| 109 | Supplying all materials, labour, T&P and constructing Manhole Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the camber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C. (a) Inside size 900mm x 900mm x 900mm |
| 110 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:2:4) mix using 12 mm size H.G chips, foundation concrete (1:4:8) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C.(a) 250MM X 250MM Gully Trap Chamber |
| 111 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.(a) 1.20 m diax 2.0 m deep soakway pit |
| 112 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast R.C.C rings joined loose gravel backing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.(a) 0.91 m diax 2.10 m deep soakway pit |
| 113 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling or floor G.I. pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling,and floor, testing all complete as per specification and the direction of the E.I.C.(a) 20mm dia C-PVC pipes |
| 114 | 15mm dia C-PVC pipes |
| 115 | supplying all materials, labour, T&P and cutting holes through existing brick/stone masonry walls for taking GI/PVC pipes and fittings including making good the damages in cement mortar (1:4) etc. all complete as per P.H. specification and direction of E.I.C.(a) walls |
| 116 | Cutting Hole in RCC Roof/Floor |
| 117 | supplying all materials, labour, T&P and cutting grooves in pucca Floors, and walls for taking G.I/PVC pipes and fittings and repairing the holes after insertion of pipes etc with C.C (1:3:6) including finishing with 12mm C.P (1:3) complete so as to make it leak proof etc. all complete as per P.H. specification and direction of E.I.C. |
| 118 | Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C.(a) Flat back lipped wall Urinal Magnum urinal |
| 119 | Supplying all materials, labour T&P and fixing wash basins with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C.(a) 550mm x 400mm W.H.basin |
| 120 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the E.I.C.(a) Mirror with plastic moulded frame |
| 121 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C. a) 20mmx450mm long CP towel rail |
| 122 | b) C.P Towel ring (St) |
| 123 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the E.I.C. (a) CP soap holder |
| 124 | Supplying all materials, labour T&P and fitting and fixing of C.P Shower with 15mm or 20mm inlet with C.P Shower arm including polishing etc all complete as per specification and direction of the E.I.C. (a) 15 mm dia C.P Shower with arm (Parryware make) |
| 125 | Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C.(a) Initial lift upto 1.5 mtr |
| 126 | From 1.5 mtr to 3.0 mtr depth |
| 127 | Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C. |
| 128 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 129 | Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 130 | Supplying all materials,labour, T&P and providing Brick work with Fly ash Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a) In foudation and Plith in C.M (1:4) |
| 131 | Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a) 20mm thick C.P (1:3) |
| 132 | Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 133 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 134 | Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 135 | Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 136 | Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C. |
| 137 | Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 138 | Supplying all materials, labour, T&P and providing 110mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C. |
| 139 | Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. |
| 140 | Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C. |
| 141 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling or floor G.I. pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling,and floor, testing all complete as per specification and the direction of the E.I.C.(a) 25mm dia PVC (ASTM) pipes |
| 142 | 32mm dia PVC (ASTM) pipes |
| 143 | 20mm dia PVC (ASTM pipes |
| 144 | Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C. (a) 15mm dia CP Bib Cock (S.B) (Jaquar make) |
| 145 | 15mm dia CP Bib Cock (L.B) (Jaquar make) |
| 146 | 15mm dia CP Angle Stop Cock (Jaquar make) |
| 147 | 15mm dia CP Concealed Stop Cock (Jaquar make) |
| 148 | 15mm dia CP Pillar Cock (Jaquar make) |
| 149 | 15mm dia CP 2-in1 Bib Cock (Jaquar make) |
| 150 | 15mm dia CP Health Fuccet |
| 151 | 25mm dia PVC Full Way Valve |
| 152 | 32mm dia PVC Full Way Valve |
| 153 | 15mm dia CP Extension Nipple |
| 154 | 15mm dia CP Flange |
| 155 | Supplying all materials, labour T&P and fitting and fixing 10 Ltrs capacity PVC low level flushing cistern with a pair of C.I. or M.S.brackets complete with fittings such as syphonic arrangement, 15mm nominal size Brass/PVC ball valve with polythene float, CP/Brass handle, unions and couplings for connection with inlet, outlet, overflow pipes, 32mm dia PVC flush bend, 15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C. (a) 10 lit PVC L/L Cistern |
| 156 | Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a) 2000 lits capacity on the roof of 1st floor |
| 157 | Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank conforming to 15701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.(a) 2000 lits capacity on the roof of 1st floor Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender