Power Government Departments Closing in 6 days TDR #58476630

Tender For Supply Installation Testing and Commissioning of 8 Mtr Minimast With 5Nos Of 150W Led Flood Light At Kotepeedika Junction In Nellikuzhi Gp,Kothamangalam Block Under Mplads 2025-26 Of Sri. Adv. Dean Kuriakose Mp

Issued by Government Departments · Malappuram, Kerala
Tender Value
1.67 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
6 days left
EMD
4188
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of 8 Mtr Minimast With 5Nos Of 150W Led Flood Light At Kotepeedika Junction In Nellikuzhi Gp,Kothamangalam Block Under Mplads 2025-26 Of Sri. Adv. Dean Kuriakose Mp

BOQ

Name of Work:- SITC of 8 Mtr Minimast with 5nos of 150W LED Flood Light at Kotepeedika Junction in Nellikuzhi GP,Kothamangalam Block under MPLADS 2025-26 of Sri. Adv. Dean Kuriakose MP
Sl. No. Item Description
1Civil Work
22.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil
34.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources)
45.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete
55.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more
65.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources)
72.25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
8Electrical Work
990.15.1.1Supply installation testing and commissioning of Octogaonal Pole made of hot dipgalvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mmbase plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 PartIII fixed head frame including round arm luminary carriage suitable to install 4/6 nosluminaries in symmetrical arrangement including connector foundation bolt 4 nosexisting RCC foundation and junction box etc, complete 8 Meters
10OD157798/2026-2027Supply Conveyance, installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance
1190.14.5Supply and fabrication conveyance and installation of angle iron frame work for wallmounting panel board
1290.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor orwall mounting, dust and vermin proof, cubicle type MV panel board comprising ofthe following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
1390.14.3.2Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU'section rubber beeding suitable for 1.60/ 2.00 mm sheet
14OD157299/2026-2027Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a25A/1.5HP capacity. It features 5 On/Off program settings for daily and weeklyschedules, along with manual start, ON delay, and OFF delay settings. Equipped witha high-precision, industrial-grade chip and strong anti-interference capabilities, thetimer can automatically turn on and off the power supply of various electricalequipment according to the time set by the user. The controlled objects can includestreet lights, light boxes, neon lights, and high/mini mast systems. It also includes asufficient battery backup for time memory in case of power failure, and comes withsuitable fittings for use in a distribution box or MV panel with FRLS PVC insulated.5 mm single core cable suitable for control wiring towards contactor
15OD157302/2026-2027Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hzoperation. It can control street lights, light boxes, neon lights, high/mini mast systems,and induction loads.
16OD157306/2026-2027Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5 sq. mm
17OD157301/2026-2027Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. Specifications include: Voltage Protection Level (Up), Nominal Voltage: 230V, UOC: 10kV, L-N: 7kV, L-PE: 7kV, N-PE: 7kV, Nominal Discharge Current (8/20µs): 10kA, Total Discharge Current (8/20µs): 60kA, Response Time: <35 ns, Ambient Temperature (Ta): -10 to 55°C.
18OD157298/2026-2027Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- wayneutral links mounted on DMC/SMC base.
192.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
202.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole
212.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
222.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
23OD157305/2026-2027Supply and installation of 1.5 Sqmm non-insulated CP-1 pin terminals with suitablesize heat shrink
24OD157303/2026-2027Supply and installation of 2.5 Sqmm non-insulated CP-1 pin terminals with suitablesize heat shrink
2590.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 2.50 sq mm
2690.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm
2790.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
285.3Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2990.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
3090.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
3190.12.1.13Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in ground includingexcavation of trench of size 35 x 75 cm, refilling the trench etc. as required butexcluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
3290.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size
33OD157304/2026-2027Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required. 3 X 6 sq. mm (19mm)
34OD157300/2026-2027Fabrication ,supply, conveyance and installation of Granite name board indicating thecost involved, the commencement, completion and inauguration date etc Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58476630
AUTHORITY Government Departments
TENDER VALUE 1.67 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Supply Installation Testing and Commissioning of 8 Mtr Minimast With 5Nos Of 150W Led Flood Light At Kotepeedika Junction In Nellikuzhi Gp,Kothamangalam Block Under Mplads 2025-26 Of Sri. Adv. Dean Kuriakose Mp
Basic Detail
Tender No KEL/ KEMG/199/2026-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 11 Nov 2026
Submission Date 18 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 1.67 Lakhs
Tender Fee 590
EMD 4188
Exemption Available
Document List
0f6a1095-b94a-4f7a-90c2-a9f8a557b563.html
BOQ_1515854.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

0f6a1095-b94a-4f7a-90c2-a9f8a557b563.html

xls

BOQ_1515854.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender