Power Boards / Undertakings / PSU Closing in 16 days TDR #58472188

Tender For Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.

Issued by Boards / Undertakings / PSU · Dima Hasao, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Nov 2026
16 days left
EMD
11.20 Crore
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dima Hasao → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Nov-2026 Corrigendum-IV Other 30-Nov-2026

BOQ

Name of Work:- Construction of new 400/132kV Umrangshu Grid Substation along with Associated Transmission System at Dima Hasao District, Assam.
Sl. No. Item Description
1Grand Summery
2PRICE SCHEDULE-1 (Supply) 400kV New Substation
3PRICE SCHEDULE-2 (Freight & Insurance (F&I)) 400kV New Substation
4PRICE SCHEDULE-3 (Erection, Testing & Commissioning (ETC) including civil works) 400kV New Substation
5PRICE SCHEDULE-4 Civil Works 400kV New Substation
6PRICE SCHEDULE-5 (Supply) 132kV Old Substation (Remote End)
7PRICE SCHEDULE-6 (Freight & Insurance (F&I)) 132kV Old Substation (Remote End)
8PRICE SCHEDULE-7 (Erection, Testing & Commissioning (ETC) including Civil Works) 132kV Old Substation (Remote End)
9PRICE SCHEDULE-8 Civil Works 132kV Old Substation (Remote End)
10PRICE SCHEDULE-9 (Supply) 400kV Misa-Silchar D/C LILO at Umrangshu (Quad Moose)
11PRICE SCHEDULE-10 (Freight & Insurance (F&I)) 400kV Misa-Silchar D/C LILO at Umrangshu (Quad Moose)
12PRICE SCHEDULE-11 (Erection, Testing & Commissioning (ETC) including Civil Works) 400kV Misa-Silchar D/C LILO at Umrangshu (Quad Moose)
13PRICE SCHEDULE-12 (Supply) 132kV Umrangshu(New)-Umrangshu(Old) D/C (Single Panther)
14PRICE SCHEDULE-13 (Freight & Insurance (F&I)) 132kV Umrangshu(New)-Umrangshu(Old) D/C (Single Panther)
15PRICE SCHEDULE-14 (Erection, Testing & Commissioning (ETC) including Civil Works) 132kV Umrangshu(New)-Umrangshu(Old) D/C (Single Panther)
16Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
17145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
18145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
19145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
20145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
2172.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
2272.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
23Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
24145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
25145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
26145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
27145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
2872.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
2972.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
30Supply of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required. and as per spefication
31400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
32400kV, 2X160kN Double tension string suitable for Single Moose conductor.
33400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
34132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
35132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
36132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
37132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
38132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
39Supply of Conductors, Clamp Connectors as required and as per spefication
404'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
41ACSR Moose Conductor as per site requirement
42Clamps & Connectors as per requirement
43Supply of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
44420KV, BPI
45145KV, BPI
4672.5KV, BPI
47Supply of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
48420KV, BPI
49145KV, BPI
5072.5KV, BPI
51Supply of Station Service Transformer (Energy efficiency level-3) and accessories as per specification.
52630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
53440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
54Supply of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
55398kV, 20kA, LA
56120kV, 10kA, LA
5760kV, 10kA, LA
58Supply of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
59398kV, 20kA, LA
60120kV, 10kA, LA
6160kV, 10kA, LA
62Supply of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
63400kV, 8800pF, 3 Wdg CVT.
64132kV, 4400pF, 3 Wdg CVT.
65400KV, 3150A Wave Trap
66132KV, 800A Wave Trap.
67Supply of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
68400kV, 8800pF, 3 Wdg CVT.
69132kV, 4400pF, 3 Wdg CVT.
70Supply of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
71145kV, 3150A, 40kA for 3 sec.
7272.5kV, 1250A, 40kA for 3 sec.
73Supply of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
74400kV BMK
75132kV BMK
76Supply of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
77132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
78132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
79132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
8072.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
81132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
8272.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
83Supply of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
84132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
85132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
86132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
8772.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
88132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
8972.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
90Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 400kV GIS
91400kV Bus Bar Protection Panel
92400kV Line CRP
93400/132kV ICT CRP (315MVA)
94400kV Bus Reactor CRP
95400kV Tie Breaker CRP
96Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
97132kV Line CRP (with line differential)
98400/132kV Transformer CRP (315MVA)
99132kV Bus Coupler CRP
100132kV Bus Bar CRP
101Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 72.5kV AIS
102Station Service Transformer control & Protection Panel
103Relevant software for relay configuration & setting, maintenance etc.
104Supply of Phasor Measurement Unit as required and as per specification.
105Phasor Measurement Unit
106Supply of Complete Substation System Automation System (As per specification)
107Station HMI (Main, Redundant and Metering) with Industrial PC
108Maintenance HMI (DR Workstation) with Industrial PC
109Gate way with PLCC and Fibre Optic Modem and Panel
110SAS Inverter (5kVA)
111Colour Laser MFM Printer
112GPS Clock System
11316 port Ethernet Switch
114All interphase equipment for Gateway to SLDC
115VDU 75 inch
116Aux BCU with panel as per scheme requirement
117All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
118Station Ethernet Switch
119SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
120Red Box
121Integration of the PMU and the Meters with the PDC, CDCS
122Supply of 400 kV GIS Equipment as per specification.
1233- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
1243- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
1253- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
1263- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
1273- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
1283- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
129400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
130400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
13110 Ton EOT Crane for 400kV GIS Building
132Scissor Lift
133Supply of Testing And Maintenance Equipment of GIS as specified.
134SF6 Gas Processing, Drying, Storage & Filling Unit
135SF6 gas quality testing unit
136SF6 Gas Leak Detector
137SF6 gas Mask
138Supply of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2, ICT along with all accessories and below: (including terminal connectors and other acessories as per technical specification)
139315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
140Oil & winding temperature monitoring system (FO based)
141Online DGA (Multi gas)
142Online insulating drying system
143Maintenance free breather
144RTCC Panel with AVR (TMS)
14510% Extra OIL for each transformer
146Rail track for transformer
147Pulling block for transformer
148Supply of 80 MVAR Bus Reactor (with Oil) as per specification.
14980 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
150Pulling block for reactor
151Supply of Battery & Battery Chargers, DCDB & ACDB as per specification
152220V VRLA Battery 1600AH
153220V, Dual Float Cum Boost Chargers for 220V Battery 350A
154220V, DCDB
15548V VRLA type Battery Bank 600AH
15648V, Dual Float cum Boost Chargers for 48V Battery 130A
15748V, DCDB
158Main ACDB
159Sub ACDB
160MLDB with 415V/415V, 100kVA isolation transformer
161ELDB with 415V/415V, 50kVA isolation transformer
162HVAC DB
163MCBDB
164Aux ACDBs, Sub DCDBs etc, as per requirement
165Supply of Power Line Carrier Communication Equipments as per specification
166HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
167Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
168Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
169IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
170IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
171LMU and LMDU
172EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
173CAT 6 armoured cable.
1742 wire telephone set
175Audio Cable
176Supply of OPGW equipments as per specification as per specificationTransmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
177Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
178Supply of OPGW equipments as per specification as per specificationOptical Interface/SFP for:
179SFP to support STM-4 upto 150km.
180SFP to support STM-16 upto 150km.
181Supply of OPGW equipments as per specification as per specificationTributary Cards
182E1 interface card (Minimum 63 interfaces per card)
183Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
1848 Port VOIP for remote locations
185Analog Telephone( 2-wire telephone for VOIP Gateway location)
186IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
187Supply of OPGW equipments as per specification as per specificationEquipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
188For SDH equipment(including DDF patching facilities and other accessories
189Main Distribution Frame(100 pairs)
190Supply of OPGW equipments as per specification as per specificationCraft Terminal
191Hardware (LAPTOP)
192Software
193Pre connectorized optical patch cords(Minium 8 patch cords per station)
194Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
195Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
196Supply of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
1972C, 6sqmm Cu
1984C, 16sqmm Cu
1993.5C, 35sqmm Al
2001C, 150sqmm Cu
2013.5C, 70sqmm Al
2023.5C, 150sqmm Al
2033.5C, 400sqmm Al
204Cable supports and other cable accessories
205Others ( Cable for Fire Fighting, Illumination etc)
206Supply of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
2074C, 2.5sqmm
2085C, 2.5sqmm
2097C, 2.5sqmm
21012C, 2.5sqmm
21117C, 2.5sqmm
21219C, 2.5sqmm
213Cable supports and other cable accessories
214Supply of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
21540 mm Dia MS Rod for Main/Auxiliary Earthmat
216Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
217Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
218Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
219Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
220Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
221Soil Resistivity Test And Soil Treatment As And When Required
222Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
223Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
224Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
225Supply of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
226400kV Columns with peak
227400kV Beams
228132kV Columns with/without peak
229132kV Beams
230Supply of Fire Alarm & Detection including all accessories as per specification
231Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
232Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for 400kV GIS Hall each (5kg X 6 Nos),Control room (2kg X 6 Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Switchyard (5kg X 4Nos) ( as per specification.
233Dry powder chemical type 10 kg. For 630 kVA transformer
234Fire fire fighting system (sprinkler system) for control room as per requirement
235Supply of HVAC & VENTILATION
2362 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
237Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
238Supply of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including all accessories as per specification.
239Hydrant system along with pumping arrangement & associated Civil works for fire protection system
240HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
241NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
242250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
243Lighting System Supply of Outdoor Lighting
244Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
245Supply of Public Addressing System & CCTV complete with all accessories as per specification.
246Public Addressing System & CCTV complete with all accessories as per specification.
247Supply of Lightining System
248Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
249F&I of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
250145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
251145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
252145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
253145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
25472.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
25572.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
256F&I of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
257145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
258145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
259145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
260145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
26172.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
26272.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
263F&I of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required. and as per spefication
264400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
265400kV, 2X160kN Double tension string suitable for Single Moose conductor.
266400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
267132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
268132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
269132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
270132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
271132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
272F&I of Conductors, Clamp Connectors as required and as per spefication
2734'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
274ACSR Moose Conductor as per site requirement
275Clamps & Connectors as per requirement
276F&I of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
277420KV, BPI
278145KV, BPI
27972.5KV, BPI
280F&I of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
281420KV, BPI
282145KV, BPI
28372.5KV, BPI
284F&I of Station Service Transformer (Energy efficiency level-3) and accessories as per specification.
285630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
286440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
287F&I of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
288398kV, 20kA, LA
289120kV, 10kA, LA
29060kV, 10kA, LA
291F&I of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
292398kV, 20kA, LA
293120kV, 10kA, LA
29460kV, 10kA, LA
295F&I of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
296400kV, 8800pF, 3 Wdg CVT.
297132kV, 4400pF, 3 Wdg CVT.
298400KV, 3150A Wave Trap
299132KV, 800A Wave Trap.
300F&I of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
301400kV, 8800pF, 3 Wdg CVT.
302132kV, 4400pF, 3 Wdg CVT.
303F&I of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
304145kV, 3150A, 40kA for 3 sec.
30572.5kV, 1250A, 40kA for 3 sec.
306F&I of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
307400kV BMK
308132kV BMK
309F&I of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
310132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
311132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
312132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
31372.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
314132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
31572.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
316F&I of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
317132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
318132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
319132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
32072.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
321132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
32272.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
323F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 400kV GIS
324400kV Bus Bar Protection Panel
325400kV Line CRP
326400/132kV ICT CRP (315MVA)
327400kV Bus Reactor CRP
328400kV Tie Breaker CRP
329F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
330132kV Line CRP (with line differential)
331400/132kV Transformer CRP (315MVA)
332132kV Bus Coupler CRP
333132kV Bus Bar CRP
334F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 72.5kV AIS
335Station Service Transformer control & Protection Panel
336Relevant software for relay configuration & setting, maintenance etc.
337F&I of Phasor Measurement Unit as required and as per specification.
338Phasor Measurement Unit
339F&I of Complete Substation System Automation System (As per specification)
340Station HMI (Main, Redundant and Metering) with Industrial PC
341Maintenance HMI (DR Workstation) with Industrial PC
342Gate way with PLCC and Fibre Optic Modem and Panel
343SAS Inverter (5kVA)
344Colour Laser MFM Printer
345GPS Clock System
34616 port Ethernet Switch
347All interphase equipment for Gateway to SLDC
348VDU 75 inch
349Aux BCU with panel as per scheme requirement
350All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
351Station Ethernet Switch
352SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
353Red Box
354Integration of the PMU and the Meters with the PDC, CDCS
355F&I of 400 kV GIS Equipment as per specification.
3563- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
3573- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
3583- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
3593- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
3603- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
3613- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
362400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
363400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
36410 Ton EOT Crane for 400kV GIS Building
365Scissor Lift
366F&I of Testing And Maintenance Equipment of GIS as specified.
367SF6 Gas Processing, Drying, Storage & Filling Unit
368SF6 gas quality testing unit
369SF6 Gas Leak Detector
370SF6 gas Mask
371F&I of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2, ICT along with all accessories and below: (including terminal connectors and other acessories as per technical specification)
372315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
373Oil & winding temperature monitoring system (FO based)
374Online DGA (Multi gas)
375Online insulating drying system
376Maintenance free breather
377RTCC Panel with AVR (TMS)
37810% Extra OIL for each transformer
379Rail track for transformer
380Pulling block for transformer
381F&I of 80 MVAR Bus Reactor (with Oil) as per specification.
38280 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
383Pulling block for reactor
384F&I of Battery & Battery Chargers, DCDB & ACDB as per specification
385220V VRLA Battery 1600AH
386220V, Dual Float Cum Boost Chargers for 220V Battery 350A
387220V, DCDB
38848V VRLA type Battery Bank 600AH
38948V, Dual Float cum Boost Chargers for 48V Battery 130A
39048V, DCDB
391Main ACDB
392Sub ACDB
393MLDB with 415V/415V, 100kVA isolation transformer
394ELDB with 415V/415V, 50kVA isolation transformer
395HVAC DB
396MCBDB
397Aux ACDBs, Sub DCDBs etc, as per requirement
398F&I of Power Line Carrier Communication Equipments as per specification
399HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
400Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
401Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
402IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
403IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
404LMU and LMDU
405EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
406CAT 6 armoured cable.
4072 wire telephone set
408Audio Cable
409F&I of OPGW equipments as per specification as per specificationTransmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
410Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
411F&I of OPGW equipments as per specification as per specificationOptical Interface/SFP for:
412SFP to support STM-4 upto 150km.
413SFP to support STM-16 upto 150km.
414F&I of OPGW equipments as per specification as per specificationTributary Cards
415E1 interface card (Minimum 63 interfaces per card)
416Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
4178 Port VOIP for remote locations
418Analog Telephone( 2-wire telephone for VOIP Gateway location)
419IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
420F&I of OPGW equipments as per specification as per specificationEquipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
421For SDH equipment(including DDF patching facilities and other accessories
422Main Distribution Frame(100 pairs)
423F&I of OPGW equipments as per specification as per specificationCraft Terminal
424Hardware (LAPTOP)
425Software
426Pre connectorized optical patch cords(Minium 8 patch cords per station)
427Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
428Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
429F&I of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
4302C, 6sqmm Cu
4314C, 16sqmm Cu
4323.5C, 35sqmm Al
4331C, 150sqmm Cu
4343.5C, 70sqmm Al
4353.5C, 150sqmm Al
4363.5C, 400sqmm Al
437Cable supports and other cable accessories
438Others ( Cable for Fire Fighting, Illumination etc)
439F&I of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
4404C, 2.5sqmm
4415C, 2.5sqmm
4427C, 2.5sqmm
44312C, 2.5sqmm
44417C, 2.5sqmm
44519C, 2.5sqmm
446Cable supports and other cable accessories
447F&I of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
44840 mm Dia MS Rod for Main/Auxiliary Earthmat
449Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
450Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
451Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
452Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
453Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
454Soil Resistivity Test And Soil Treatment As And When Required
455Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
456Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
457Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
458F&I of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
459400kV Columns with peak
460400kV Beams
461132kV Columns with/without peak
462132kV Beams
463F&I of Fire Alarm & Detection including all accessories as per specification
464Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
465Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for 400kV GIS Hall each (5kg X 6 Nos),Control room (2kg X 6 Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Switchyard (5kg X 4Nos) ( as per specification.
466Dry powder chemical type 10 kg. For 630 kVA transformer
467Fire fire fighting system (sprinkler system) for control room as per requirement
468F&I of HVAC & VENTILATION
4692 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
470Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
471F&I of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including all accessories as per specification.
472Hydrant system along with pumping arrangement & associated Civil works for fire protection system
473HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
474NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
475250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
476Lighting System F&I of Outdoor Lighting
477Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
478F&I of Public Addressing System & CCTV complete with all accessories as per specification.
479Public Addressing System & CCTV complete with all accessories as per specification.
480F&I of Lightining System
481Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
482Erection of Isolator mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
483145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
484145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
485145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
486145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
48772.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
48872.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
489Erection Testing and Commissioning of Isolators with all accessories, laying and termination of LT power & control cables, fitting fixing of clamps and jumpers etc. as required.
490145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
491145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
492145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
493145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
49472.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
49572.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
496Hoisting and erection of hardware fittings complete set with nuts bolts, clamps and other accessories as required and stringing of Bus/conductor/jumpers as required.
497400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
498400kV, 2X160kN Double tension string suitable for Single Moose conductor.
499400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
500132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
501132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
502132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
503132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
504132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
505Erection Testing and Commissioning of Conductors, Clamp Connectors as required and as per spefication
5064'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
507ACSR Moose Conductor as per site requirement
508Clamps & Connectors as per requirement
509Erection of BPI mounting structures including contsruction of foundation and supply of all foundation materials and labour etc.
510420KV, BPI
511145KV, BPI
51272.5KV, BPI
513Erection, Testing & Commissioning of 1 phase Solid core bus post insulator including clamp connectors and other accessories as required.
514420KV, BPI
515145KV, BPI
51672.5KV, BPI
517Erection Testing and Commissioning of Station Service Transformer, PRP (with structure, if applicable) and its accessories as below including laying and termination of LT power and control cables
518630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
519440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
520Erection of LA mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
521398kV, 20kA, LA
522120kV, 10kA, LA
52360kV, 10kA, LA
524Erection, Testing & Commissioning of Surge Arrester alongwith erection of mounting structure, Including fitting and fixing of all accessories, clamps and connectors etc complete.
525398kV, 20kA, LA
526120kV, 10kA, LA
52760kV, 10kA, LA
528Erection Testing & Commissioning of CVT and Wave Trap alongwith erection (for CVT), of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc.
529400kV, 8800pF, 3 Wdg CVT.
530132kV, 4400pF, 3 Wdg CVT.
531400KV, 3150A Wave Trap
532132KV, 800A Wave Trap.
533Erection of CVT mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
534400kV, 8800pF, 3 Wdg CVT.
535132kV, 4400pF, 3 Wdg CVT.
536Erection Testing & Commissioning of Circuit Breaker (Outdoor AIS) alongwith erection of mounting structures, laying and termination of LT power and control cables including fitting and fixing of all accessories, clamps and connectors and including contsruction of foundation and supply of all foundation materials and labour complete.
537145kV, 3150A, 40kA for 3 sec.
53872.5kV, 1250A, 40kA for 3 sec.
539Erection Testing & Commissioning of Bay Marshalling Kiosk alongwith structure including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour as required.
540400kV BMK
541132kV BMK
542Erection of Instrument Transformer (CT & PT) mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
543132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
544132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
545132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
54672.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
547132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
54872.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
549Erection Testing & Commissioning of Instrument Transformer (CT & PT) alongwith erection of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc complete.
550132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
551132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
552132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
55372.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
554132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
55572.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
556Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 400kV GIS
557400kV Bus Bar Protection Panel
558400kV Line CRP
559400/132kV ICT CRP (315MVA)
560400kV Bus Reactor CRP
561400kV Tie Breaker CRP
562Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 132kV AIS
563132kV Line CRP (with line differential)
564400/132kV Transformer CRP (315MVA)
565132kV Bus Coupler CRP
566132kV Bus Bar CRP
567Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 72.5kV AIS
568Station Service Transformer control & Protection Panel
569Relevant software for relay configuration & setting, maintenance etc.
570Erection Testing & Commissioning and installation of Phasor Measurement Unit as required and as per specification.
571Phasor Measurement Unit
572Erection Testing & Commissioning and installation of Complete Substation System Automation System (As per specification) including laying and termination of LT power and control cables
573Station HMI (Main, Redundant and Metering) with Industrial PC
574Maintenance HMI (DR Workstation) with Industrial PC
575Gate way with PLCC and Fibre Optic Modem and Panel
576SAS Inverter (5kVA)
577Colour Laser MFM Printer
578GPS Clock System
57916 port Ethernet Switch
580All interphase equipment for Gateway to SLDC
581VDU 75 inch
582Aux BCU with panel as per scheme requirement
583All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
584Station Ethernet Switch
585SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
586Red Box
587Integration of the PMU and the Meters with the PDC, CDCS
588Erection Testing & Commissioning and installation of 400 kV GIS Modules and Equipment including laying and termination of LT power and control cables, installation of all accessories as required including construction of foundation and supply of all foundation materials and labour.
5893- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
5903- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
5913- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
5923- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
5933- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
5943- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
595400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
596400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
59710 Ton EOT Crane for 400kV GIS Building
598Scissor Lift
599Installation and demo of Testing And Maintenance Equipment of GIS
600SF6 Gas Processing, Drying, Storage & Filling Unit
601SF6 gas quality testing unit
602SF6 Gas Leak Detector
603SF6 gas Mask
604Erection, testing and commissioning of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2 ICT and all accessories, terminal connectors as per technical specification including laying and termination of LT power, control cables and other signalling cables as required.
605315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
606Oil & winding temperature monitoring system (FO based)
607Online DGA (Multi gas)
608Online insulating drying system
609Maintenance free breather
610RTCC Panel with AVR (TMS)
611Rail track for transformer
612Pulling block for transformer
613Erection, Testing & Commissioning of 80 MVAR Bus Reactor including laying and termination of LT power and control cables and other signalling cables as required.
61480 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
615Pulling block for reactor
616Erection, Testing & Commissioning of Battery & Battery Chargers, DCDB & ACDB as per specification including laying and termination of LT power and control cables as required.
617220V VRLA Battery 1600AH
618220V, Dual Float Cum Boost Chargers for 220V Battery 350A
619220V, DCDB
62048V VRLA type Battery Bank 600AH
62148V, Dual Float cum Boost Chargers for 48V Battery 130A
62248V, DCDB
623Main ACDB
624Sub ACDB
625MLDB with 415V/415V, 100kVA isolation transformer
626ELDB with 415V/415V, 50kVA isolation transformer
627HVAC DB
628MCBDB
629Aux ACDBs, Sub DCDBs etc, as per requirement
630Erection, Testing & Commissioning of Power Line Carrier Communication Equipments including laying and termination of LT power and control cables
631HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
632Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
633Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
634IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
635IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
636LMU and LMDU
637EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
638CAT 6 armoured cable.
6392 wire telephone set
640Audio Cable
641Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Transmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
642Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
643Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Optical Interface/SFP for:
644SFP to support STM-4 upto 150km.
645SFP to support STM-16 upto 150km.
646Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Tributary Cards
647E1 interface card (Minimum 63 interfaces per card)
648Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
6498 Port VOIP for remote locations
650Analog Telephone( 2-wire telephone for VOIP Gateway location)
651IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
652Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Equipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
653For SDH equipment(including DDF patching facilities and other accessories
654Main Distribution Frame(100 pairs)
655Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Craft Terminal
656Hardware (LAPTOP)
657Software
658Pre connectorized optical patch cords(Minium 8 patch cords per station)
659Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
660Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
661Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
662400kV Columns with peak
663Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
664132kV Columns with/without peak
665Installation & Testing of complete Earthing system as per technical specification.
66640 mm Dia MS Rod for Main/Auxiliary Earthmat
667Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
668Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
669Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
670Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
671Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
672Soil Resistivity Test And Soil Treatment As And When Required
673Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
674Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
675Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
676Erection of Lattice structures for incoming and outgoing gantries etc.
677400kV Columns with peak
678400kV Beams
679132kV Columns with/without peak
680132kV Beams
681Installation and Testing & Commissioning of Fire Alarm & Detection including laying and termination of LT power and control cables
682Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
683Fire fire fighting system (sprinkler system) for control room as per requirement
684Erection, testing, commissioning HVAC & VENTILATION
6852 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
686Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
687Erection and Testing & Commissioning of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including laying and termination of LT power and control cables
688Hydrant system along with pumping arrangement & associated Civil works for fire protection system
689HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
690NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
691250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
692Erection and Testing & Commissioning of Lighting System including laying and termination of illumination cables, GI shield wires etc.
693Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
694Erection and Testing & Commissioning of Public Addressing System & CCTV complete with all accessories as per specification.
695Public Addressing System & CCTV complete with all accessories as per specification.
696Erection and Testing & Commissioning of Lightining including laying and termination of illumination cables, GI shield wires etc.
697Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation alongwith construction of foundation and supply of all foundation materials and labour and earthing arrangement
698Site Preparation Works
699Soil Investigation
700Site Clearance including necessary excavation and dismantling of existing structure
701Standards, Design and Drawing
702Site Preparation and Earthfilling with Compaction
703Earthcutting and necessary levelling
704RCC Retaining wall with counterfort wall
705Boulder Pitching with 100 mm PCC on top
706Brick Boundary wall
707Security Fencing
708Buildings (including All services i.e. electrical, internal water supply, sanitary works, sewage system, furnishing, cable trench (present and future) complete)
709400 KV GIS cum Control Room/CRP/DB Building (PEB) alongwith GIS bay foundations complete [75m x (16+8)m]
710Constrcution of Transformer and Reactor foundation including road cum rail track and all other accessories required for complete job
711Counstruction of 315 MVA Power Transformer foundation with Burnt Oil Pit
712Counstruction of 80MVAR Bus Reactor foundation with Burnt Oil Pit
713Fire Protection Wall in RCC frame with 230 mm brick wall including supply of all foundation materials and labour on pile foundation
714Fire Protection Wall for 315 MVA Transformer
715Fire Protection Wall for 80 MVAr Reactor
716HVWS with Water reserviour and Pumphouse
717Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (200 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe and Construction of Water reservior and Pump house for fire fighting.
718Water Supply work
719Construction of RCC (M-25 grade) reservoir 600 mm above FGL (Capacity 15000 Ltr) alongwith supply and Installation of distribution network with CPVC pipe of 40 mm diameter and 25 mm diameter for connecting to Overhead tank of all buildings.
720Cable Trench along with road crossing culvert for cables wherever necesarry along with switchyard work
721A type
722B Type
723C Type
724D Type
725HDPE pipe of 150 mm dia
726RCC Box Culvert
727Approach Road (RCC)
728Internal Road (RCC)
729Antiweed treatment
730PCC in Switchyard
731Stone Spreading(Gravelling) in switchyard
732Storm Water Drain
733Sump Pit with electric pump set
734Main Gate
735Switchyard Gate
736Rain water Harvesting with construction of RCC reservoir
737Rain water Harvesting with construction of RCC reservoir
738Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
739145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
740145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
741Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
742145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
743145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
744Supply of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required and as per spefication
745132kV, 2x70kN double suspension string suitable for Twin Panther conductors
746132kV, 2x90kN double tension string suitable for Twin Panther conductors
747132kV, 90kN tension string suitable for Single Panther conductor.
748132kV, 70kN suspension string suitable for Single Panther conductor.
749Supply of Conductors, Clamp Connectors as required and as per spefication
750ACSR Panther Conductor as per site requirement
751Clamps & Connectors as per requirement
752Supply of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
753145KV, BPI
754Supply of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
755145KV, BPI
756Supply of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
757120kV, 10kA, LA
758Supply of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
759120kV, 10kA, LA
760Supply of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
761132kV, 4400pF, 3 Wdg CVT.
762132KV, 800A Wave Trap.
763Supply of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
764132kV, 4400pF, 3 Wdg CVT.
765Supply of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
766145kV, 3150A, 40kA for 3 sec.
767Supply of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
768132kV BMK
769Supply of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
770132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
771Supply of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
772132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
773Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
774132kV Line CRP (with line differential)
775Supply of Substation System Automation System (As per specification)
77616 port Ethernet Switch
777SAMAST compliant ABT meters
778Integration of two new CRP's with the existing SAS
779Supply of Power Line Carrier Communication Equipments as per specification
780HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
781Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
782IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
783LMU and LMDU
784CAT 6 armoured cable.
7852 wire telephone set
786Audio Cable
787Supply of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
7882C, 6sqmm Cu
7894C, 16sqmm Cu
790Cable supports and other cable accessories
791Supply of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
7925C, 2.5sqmm
79312C, 2.5sqmm
79419C, 2.5sqmm
795Cable supports and other cable accessories
796Supply of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
79775 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
798Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
799Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
800Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
801Soil Resistivity Test And Soil Treatment As And When Required
802Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
803Supply of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
804132kV Columns with/without peak
805132kV Beams
806Lighting System Supply of Outdoor Lighting
807Outdoor LED lighting for new extended switchyard area
808Supply of Lightining System
809Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
810F&I of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
811145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
812145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
813F&I of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
814145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
815145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
816F&I of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required and as per spefication
817132kV, 2x70kN double suspension string suitable for Twin Panther conductors
818132kV, 2x90kN double tension string suitable for Twin Panther conductors
819132kV, 90kN tension string suitable for Single Panther conductor.
820132kV, 70kN suspension string suitable for Single Panther conductor.
821F&I of Conductors, Clamp Connectors as required and as per spefication
822ACSR Panther Conductor as per site requirement
823Clamps & Connectors as per requirement
824F&I of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
825145KV, BPI
826F&I of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
827145KV, BPI
828F&I of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
829120kV, 10kA, LA
830F&I of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
831120kV, 10kA, LA
832F&I of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
833132kV, 4400pF, 3 Wdg CVT.
834132KV, 800A Wave Trap.
835F&I of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
836132kV, 4400pF, 3 Wdg CVT.
837F&I of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
838145kV, 3150A, 40kA for 3 sec.
839F&I of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
840132kV BMK
841F&I of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
842132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
843F&I of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
844132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
845F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
846132kV Line CRP (with line differential)
847F&I of Substation System Automation System (As per specification)
84816 port Ethernet Switch
849SAMAST compliant ABT meters
850Integration of two new CRP's with the existing SAS
851F&I of Power Line Carrier Communication Equipments as per specification
852HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
853Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
854IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
855LMU and LMDU
856CAT 6 armoured cable.
8572 wire telephone set
858Audio Cable
859F&I of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
8602C, 6sqmm Cu
8614C, 16sqmm Cu
862Cable supports and other cable accessories
863F&I of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
8645C, 2.5sqmm
86512C, 2.5sqmm
86619C, 2.5sqmm
867Cable supports and other cable accessories
868F&I of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
86975 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
870Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
871Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
872Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
873Soil Resistivity Test And Soil Treatment As And When Required
874Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
875F&I of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
876132kV Columns with/without peak
877132kV Beams
878Lighting System F&I of Outdoor Lighting
879Outdoor LED lighting for new extended switchyard area
880F&I of Lightining System
881Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
882Erection of Isolator mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
883145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
884145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
885Erection Testing and Commissioning of Isolators with all accessories, laying and termination of LT power & control cables, fitting fixing of clamps and jumpers etc. as required.
886145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
887145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
888Hoisting and erection of hardware fittings complete set with nuts bolts, clamps and other accessories as required and stringing of Bus/conductor/jumpers as required.
889132kV, 2x70kN double suspension string suitable for Twin Panther conductors
890132kV, 2x90kN double tension string suitable for Twin Panther conductors
891132kV, 90kN tension string suitable for Single Panther conductor.
892132kV, 70kN suspension string suitable for Single Panther conductor.
893Erection, Testing & Commissioning of Conductors, Clamp Connectors as required and as per spefication
894ACSR Panther Conductor as per site requirement
895Clamps & Connectors as per requirement
896Erection of BPI mounting structures including contsruction of foundation and supply of all foundation materials and labour
897145KV, BPI
898Erection, Testing & Commissioning of 1 phase Solid core bus post insulator including clamp connectors and other accessories as required.
899145KV, BPI
900Erection of LA mounting structure including contsruction of foundation and supply of all foundation materials and labour
901120kV, 10kA, LA
902Erection, Testing & Commissioning of Surge Arrester alongwith erection of mounting structure, Including fitting and fixing of all accessories, clamps and connectors etc complete.
903120kV, 10kA, LA
904Erection Testing & Commissioning of CVT and Wave Trap alongwith erection (for CVT), of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc.
905132kV, 4400pF, 3 Wdg CVT.
906132KV, 800A Wave Trap.
907Erection of CVT mounting structure including contsruction of foundation and supply of all foundation materials and labour
908132kV, 4400pF, 3 Wdg CVT.
909Erection Testing & Commissioning of Circuit Breaker (Outdoor AIS) alongwith erection of mounting structures, laying and termination of LT power and control cables including fitting and fixing of all accessories, clamps and connectors and including contsruction of foundation and supply of all foundation materials and labour complete.
910145kV, 3150A, 40kA for 3 sec.
911Erection Testing & Commissioning of Bay Marshalling Kiosk alongwith structure including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour as required.
912132kV BMK
913Erection Testing & Commissioning of Instrument Transformer (CT & PT) alongwith erection of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc complete.
914132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
915Erection of Instrument Transformer (CT & PT) mounting structure including contsruction of foundation and supply of all foundation materials and labour
916132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
917Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables
918132kV Line CRP (with line differential)
919Erection, Testing, Commissioning Substation System Automation System (As per specification )
92016 port Ethernet Switch
921SAMAST compliant ABT meters
922Integration of two new CRP's with the existing SAS
923Erection, Testing & Commissioning of Power Line Carrier Communication Equipments including laying and termination of LT power and control cables
924HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
925Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
926IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
927LMU and LMDU
928CAT 6 armoured cable.
9292 wire telephone set
930Audio Cable
931Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
932132kV Columns with/without peak
933Installation & Testing of complete Earthing system as per technical specification.
93475 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
935Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
936Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
937Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
938Soil Resistivity Test And Soil Treatment As And When Required
939Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
940Erection of Lattice structures for incoming and outgoing gantries etc.
941132kV Columns with/without peak
942132kV Beams
943Erection and Testing & Commissioning of Lighting System including laying and termination of illumination cables, GI shield wires etc.
944Outdoor LED lighting for new extended switchyard area
945Erection and Testing & Commissioning of Lightining including laying and termination of illumination cables, GI shield wires etc.
946Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
947Site Preparation Works
948Site Clearance including necessary excavation and dismantling of existing structure
949Standards, Design and Drawing
950Site Preparation and Earthfilling with Compaction
951Earthcutting and necessary levelling
952RCC Retaining wall with counterfort wall
953Boundary wall
954Buildings (including All services i.e. electrical, internal water supply, sanitary works, sewage system, furnishing complete)
955G+4 Quarter
956Water Supply work
957Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (250 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe, one unit RCC (M-25 grade) Slow Sand Filter (Capacity 10,000 Ltr/hr) along with RCC (M-25 grade) reservoir 600 mm above FGL (Capacity 35,000 Ltr) Supply and Installation of distribution network with CPVC pipe of 40 mm diameter and 25 mm diameter for connecting to Overhead tank of all buildings.
958Cable Trench along with road crossing culvert for cables wherever necesarry along with switchyard work
959C Type
960D Type
961RCC Box Culvert
962Internal Road (RCC)
963Steps from colony to CRB
964Antiweed treatment
965PCC in Switchyard
966Stone Spreading(Gravelling) in switchyard
967Storm Water Drain
968Supply of lattice-type galvanized (high-tensile steel and mild-steel) steel suspension towers, angle towers and special towers etc. complete with stubs, cleats, tower superstructures, step bolts, hangers and all associated accessories. The supply shall also include all types of galvanized iron (GI) nuts, bolts, washers, spring washers etc. required for tower assembly. All materials supplied shall conform to the relevant technical specifications and applicable standards stipulated in the tender documents.
969High Tensile Steel
970Mild Steel
971Supply of Tower Accessories
972Procurement of Danger plates.
973Procurement of Phase plates.(Set of Three)
974Procurement of Number plates.
975Procurement of anti climbing device
976Procurement of Circuit Plate
977Procurement of Bird Guard (Set of Six)
978Procurement of Bird Diverters as per CEA
979Supply of ACSR Conductor
980ACSR Moose conductor
981Supply of Power Conductor Accessories
982Stock bridge type Vibration Damper
983Mid Span Compression Joint for Conductor
984Repair Sleeve for Conductor
985Bundle Spacer suitable for Quad ACSR Moose
986Rigid Spacer for jumper suitable for Quad ACSR Moose
987Supply of Tower earthing Accessories
98850 NB dia, 3 mtr long GI pipe electrode (driven) with test link
98950x6 mm GS flat as required
990Counter Poise Earthing (Per Tower)
991Other earthing accessories like GS steel wires, lugs etc
992Supply of Fibre Optic Cables
99396 Fibre (DWSM) OPGW fibre optic cable
99496 Fibre Optic Approach Cable (DWSM96F)
995Supply of OPGW HARDWARE/FITTINGS AND TERMINATIONS
996OPGW Suspension Assembly
997OPGW double tension pass through assembly
998OPGW Double Tension Assembly for splicing location
999OPGW Tension Single Dead-end Set
1000OPGW Vibration Damper c/w pre-formed armour rods
1001Down Lead Clamp
1002Metallic joint box suitable for 96F OPGW alongwith splice kit for line and sub interface
1003Loop bracket
1004Supply of FODP
1005FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1006Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1007Supply of Anti Fog Disc Insulator Stack
1008Disc Insulator suitable for Quad ACSR Moose (400kV TL)-120 kN
1009Disc Insulator suitable for Quad ACSR Moose (400kV TL)-160 kN
1010Supply of HARDWARE FITTINGS
1011Hardware fittings for Quad ACSR Moose Conductor- Double Suspension String (Pilot) 120x2 kN
1012Hardware fittings suitable for Quad ACSR Moose Conductor- Quad Tension String 160x4 kN
1013F&I of lattice-type galvanized (high-tensile steel and mild-steel) steel suspension towers, angle towers and special towers etc. complete with stubs, cleats, tower superstructures, step bolts, hangers and all associated accessories. The supply shall also include all types of galvanized iron (GI) nuts, bolts, washers, spring washers etc. required for tower assembly. All materials supplied shall conform to the relevant technical specifications and applicable standards stipulated in the tender documents.
1014High Tensile Steel
1015Mild Steel
1016F&I of Tower Accessories
1017Procurement of Danger plates.
1018Procurement of Phase plates.(Set of Three)
1019Procurement of Number plates.
1020Procurement of anti climbing device
1021Procurement of Circuit Plate
1022Procurement of Bird Guard (Set of Six)
1023Procurement of Bird Diverters as per CEA
1024F&I of ACSR Conductor
1025ACSR Moose conductor
1026F&I of Power Conductor Accessories
1027Stock bridge type Vibration Damper
1028Mid Span Compression Joint for Conductor
1029Repair Sleeve for Conductor
1030Bundle Spacer suitable for Quad ACSR Moose
1031Rigid Spacer for jumper suitable for Quad ACSR Moose
1032F&I of Tower earthing Accessories
103350 NB dia, 3 mtr long GI pipe electrode (driven) with test link
103450x6 mm GS flat as required
1035Counter Poise Earthing (Per Tower)
1036Other earthing accessories like GS steel wires, lugs etc
1037F&I of Fibre Optic Cables
103896 Fibre (DWSM) OPGW fibre optic cable
103996 Fibre Optic Approach Cable (DWSM96F)
1040F&I of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1041OPGW Suspension Assembly
1042OPGW double tension pass through assembly
1043OPGW Double Tension Assembly for splicing location
1044OPGW Tension Single Dead-end Set
1045OPGW Vibration Damper c/w pre-formed armour rods
1046Down Lead Clamp
1047Metallic joint box suitable for 96F OPGW alongwith splice kit for line and sub interface
1048Loop bracket
1049F&I of FODP
1050FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1051Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1052F&I of Anti Fog Disc Insulator Stack
1053Disc Insulator suitable for Quad ACSR Moose (400kV TL)-120 kN
1054Disc Insulator suitable for Quad ACSR Moose (400kV TL)-160 kN
1055F&I of HARDWARE FITTINGS
1056Hardware fittings for Quad ACSR Moose Conductor- Double Suspension String (Pilot) 120x2 kN
1057Hardware fittings suitable for Quad ACSR Moose Conductor- Quad Tension String 160x4 kN
1058Survey as per Specification
1059Detail Survey
1060Check Survey
1061Concreting of foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel.
1062DD+3 (2Nos.)
1063DD+6 with Auxiliary cross arm (2Nos.)
1064Setting of Stubs
1065Setting of Stubs using adjustable probe (1Set=1No. of Tower)
1066Erection of following type tested lattice type galvanised steel suspension/Angle tower with stubs and cleats, different type of GI HT Nuts & Bolts, washers for the towers, hangers and all accessories, tower superstructure complete including step bolts, Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
1067DD+3 (2Nos.)
1068DD+6 with Auxiliary cross arm (2Nos.)
1069Installation/Fitting of Tower Accessories
1070Fitting of Danger plates.
1071Fitting of Phase plates.(Set of Three)
1072Fitting of Number plates.
1073Fitting of anti climbing device
1074Fitting of Circuit Plate
1075Fitting of Bird Guard (Set of Six)
1076Fitting of Bird Diverters as per CEA
1077Stringingof ACSR Conductor
1078Stringing of power conductors including transportation from Stores and distribution of conductors and accessories to sites and laying, stringing, tensioning , clamping, jointing, jumpering and hoisting of insulators complete including cost of all fittings and accessories not specifically mentioned elsewhere per route Km (Double circuit Tower for Quad Circuit Line) of line.
1079Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1080DD+6 with Auxiliary cross arm
1081Protection of Tower
1082Protection of Tower
1083Supply of following type tested lattice-type galvanized (high-tensile steel and mild-steel) steel suspension towers, angle towers and special towers etc. complete with stubs, cleats, tower superstructures, step bolts, hangers and all associated accessories. The supply shall also include all types of galvanized iron (GI) nuts, bolts, washers, spring washers etc. required for tower assembly. All materials supplied shall conform to the relevant technical specifications and applicable standards stipulated in the tender documents.
1084High Tensile Steel (DB+6)
1085Mild Steel (DB+6)
1086High Tensile Steel (DD+0)
1087Mild Steel (DD+0)
1088High Tensile Steel (DD+3)
1089Mild Steel (DD+3)
1090High Tensile Steel (DD+12)
1091Mild Steel (DD+12)
1092High Tensile Steel (220kV DD+12)
1093Mild Steel (220kV DD+12)
1094High Tensile Steel (220kV DD+18)
1095Mild Steel (220kV DD+12)
1096High Tensile Steel (132kV Crossing Gantry)
1097Mild Steel (132kV Crossing Gantry)
1098Supply of Tower Accessories
1099Procurement of Danger plates.
1100Procurement of Phase plates.(Set of Three)
1101Procurement of Number plates.
1102Procurement of anti climbing device
1103Procurement of Circuit Plate
1104Procurement of Bird Guard (Set of Six)
1105Procurement of Bird Diverters as per CEA
1106Supply of AAAC Conductor
1107AAAC Panthar conductor
1108Supply of Power Conductor Accessories
1109Stock bridge type Vibration Damper
1110Mid Span Compression Joint for Conductor
1111Repair Sleeve for Conductor
1112Supply of Tower earthing Accessories
111350 NB dia, 3 mtr long GI pipe electrode (driven) with test link
111450x6 mm GS flat as required
1115Counter Poise Earthing (per Tower)
1116Other earthing accessories like GS steel wires, lugs etc
1117Supply of Fibre Optic Cables
111848 Fibre (DWSM) OPGW fibre optic cable
111948 Fibre Optic Approach Cable (DWSM96F)
1120Supply of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1121OPGW Suspension Assembly
1122OPGW double tension pass through assembly
1123OPGW Double Tension Assembly for splicing location
1124OPGW Tension Single Dead-end Set
1125OPGW Vibration Damper c/w pre-formed armour rods
1126Down Lead Clamp
1127Metallic joint box suitable for 48F OPGW alongwith splice kit for line and sub interface
1128Loop bracket
1129Supply of FODP
1130FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1131Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1132Supply of Anti Fog Disc Insulator Stack
1133Disc insulator suitable for Single AAAC Panther (132 KV TL)-70 KN
1134Disc insulator suitable for Single AAAC Panther (132 KV TL)-90 KN
1135Supply of HARDWARE FITTINGS
1136Hardware fittings for Single AAAC Panther Conductor-Single Suspension String 70 kN (Pilot)
1137Hardware fittings suitable for Single AAAC Panther Conductor-Double Tension String 2x90 kN
1138Hardware fittings suitable for Single AAAC Panther Conductor-Single Tension String 90 kN
1139F&I of following type tested lattice-type galvanized (high-tensile steel and mild-steel) steel suspension towers, angle towers and special towers etc. complete with stubs, cleats, tower superstructures, step bolts, hangers and all associated accessories. The supply shall also include all types of galvanized iron (GI) nuts, bolts, washers, spring washers etc. required for tower assembly. All materials supplied shall conform to the relevant technical specifications and applicable standards stipulated in the tender documents.
1140High Tensile Steel (DB+6)
1141Mild Steel (DB+6)
1142High Tensile Steel (DD+0)
1143Mild Steel (DD+0)
1144High Tensile Steel (DD+3)
1145Mild Steel (DD+3)
1146High Tensile Steel (DD+12)
1147Mild Steel (DD+12)
1148High Tensile Steel (220kV DD+12)
1149Mild Steel (220kV DD+12)
1150High Tensile Steel (220kV DD+18)
1151Mild Steel (220kV DD+12)
1152High Tensile Steel (132kV Crossing Gantry)
1153Mild Steel (132kV Crossing Gantry)
1154F&I of Tower Accessories
1155Procurement of Danger plates.
1156Procurement of Phase plates.(Set of Three)
1157Procurement of Number plates.
1158Procurement of anti climbing device
1159Procurement of Circuit Plate
1160Procurement of Bird Guard (Set of Six)
1161Procurement of Bird Diverters as per CEA
1162F&I of AAAC Conductor
1163AAAC Panthar conductor
1164F&I of Power Conductor Accessories
1165Stock bridge type Vibration Damper
1166Mid Span Compression Joint for Conductor
1167Repair Sleeve for Conductor
1168F&I of Tower earthing Accessories
116950 NB dia, 3 mtr long GI pipe electrode (driven) with test link
117050x6 mm GS flat as required
1171Counter Poise Earthing (per Tower)
1172Other earthing accessories like GS steel wires, lugs etc
1173F&I of Fibre Optic Cables
117448 Fibre (DWSM) OPGW fibre optic cable
117548 Fibre Optic Approach Cable (DWSM96F)
1176F&I of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1177OPGW Suspension Assembly
1178OPGW double tension pass through assembly
1179OPGW Double Tension Assembly for splicing location
1180OPGW Tension Single Dead-end Set
1181OPGW Vibration Damper c/w pre-formed armour rods
1182Down Lead Clamp
1183Metallic joint box suitable for 48F OPGW alongwith splice kit for line and sub interface
1184Loop bracket
1185F&I of FODP
1186FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1187Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1188F&I of Anti Fog Disc Insulator Stack
1189Disc insulator suitable for Single AAAC Panther (132 KV TL)-70 KN
1190Disc insulator suitable for Single AAAC Panther (132 KV TL)-90 KN
1191F&I of HARDWARE FITTINGS
1192Hardware fittings for Single AAAC Panther Conductor-Single Suspension String 70 kN (Pilot)
1193Hardware fittings suitable for Single AAAC Panther Conductor-Double Tension String 2x90 kN
1194Hardware fittings suitable for Single AAAC Panther Conductor-Single Tension String 90 kN
1195Survey as per Specification
1196Detail Survey
1197Check Survey
1198Concreting of foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel.
1199DD+12
1200220kV DD+12
1201220kV DD+18
1202132kV Crossing Gantry
1203Setting of Stubs
1204Setting of Stubs using adjustable probe (1Set=1No. of Tower/Gantry)
1205Erection of following type tested lattice type galvanised steel suspension/Angle tower/Special Tower with stubs and cleats, different type of GI HT Nuts & Bolts, washers for the towers, hangers and all accessories, tower superstructure complete including step bolts, Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
1206DD+12
1207220kV DD+12
1208220kV DD+18
1209132kV Crossing Gantry
1210Installation/Fitting of Tower Accessories
1211Fitting of Danger plates.
1212Fitting of Phase plates.(Set of Three)
1213Fitting of Number plates.
1214Fitting of anti climbing device
1215Fitting of Circuit Plate
1216Fitting of Bird Guard (Set of Six)
1217Fitting of Bird Diverters as per CEA
1218Stringingof ACSR Conductor
1219Stringing of power conductors including transportation from Stores and distribution of conductors and accessories to sites and laying, stringing, tensioning , clamping, jointing, jumpering and hoisting of insulators complete including cost of all fittings and accessories not specifically mentioned elsewhere per route Km (6 conductors for Double Circuit Line) of line.
1220Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1221Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1222Protection of Tower Please Enable Macros to View BoQ information
1223Protection of Tower Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58472188
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 30-11-2026
Authority
Authority Name Assam Electricity Grid Corporation Limited
Work Description Tender for Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.
Basic Detail
Tender No AEGCL/MD/Tech-32/400kV Umrangshu/2026/BID
Bidding Type Tender
Location
City Dima Hasao
State Assam
Key Dates
Publish Date 10 Nov 2026
Submission Date 30 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 30000
EMD 11.20 Crore
Exemption Available
Document List
Additinal_Documents.rar
Additional_Documents_II.rar
Additional_Documents_III.rar
Bid_Volume_I.pdf
Bid_Volume_II.pdf
BOQ_85994.xls
c3b50a55-87be-44e8-a7f7-0fd03e9df39d.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
rar

Additinal_Documents.rar

rar

Additional_Documents_II.rar

rar

Additional_Documents_III.rar

pdf

Bid_Volume_I.pdf

pdf

Bid_Volume_II.pdf

xls

BOQ_85994.xls

html

c3b50a55-87be-44e8-a7f7-0fd03e9df39d.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender