Drinking Water Supply and Sanitation Government Departments Closing in 18 days TDR #58471918

Tender For Estimate For Electrical Fitting In P1 Tunnel Of Rsd Dam During Closure Works.

Issued by Government Departments · Pathankot, Punjab
Tender Value
35 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
18 days left
EMD
70000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Estimate For Electrical Fitting In P1 Tunnel Of Rsd Dam During Closure Works.

BOQ

Name of Work:- Estimate for Electrical Fitting in P1 Tunnel of RSD Dam during Closure works.
Sl. No. Item Description
1Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (Un-sheathed)
2Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 4 sq.mm (Un-sheathed)
3Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 16sq.mm (2Core) Un-armoured (Loose)
4Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 35sq.mm (3½ Core) Un armoured (Loose)
5Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 70sq.mm (4Core) Un-armoured (Loose)
6Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 50, 63amp. (10kA, Curve-C)
7Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Four Pole 50, 63amp. (10kA, Curve-C)
8Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-RCCB Four Pole 63amp., Sensitivity 100mA
9Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-ICTPN Switch 100amp., 415volts
10Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-ICTPN Switch 200amp., 415volts
11Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-ICTPN Switch 320amp., 415volts
12Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure)
13Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-Copper thimble cable Core size 4 - 6sq.mm
14Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-Aluminium thimble cable Core size 25 - 35 sq.mm
15Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-Aluminium thimble cable Core size 70 sq.mm
16Operation and Maintainence of all electrical fittings in P1 Tunnel for 24x7Skilled Labour/Electrician
17Operation and Maintainence of all electrical fittings in P1 Tunnel for 24x7Un-Skilled Labour
18Providing and Fixing LED lamp 120 watt IP-67 (Cool White)
19Providing and fixing water proof rechargeble LED Lamp 20 watt IP-67 including lamp holder and complete in all respects
20Providing and fixing Wodden Reactangular Balli 300 mm width 2.5 Mtr Height for holding cable and lights
21Supplying PVC Tape Box Water Proof
22Supplying Rubber Tape
23Supplying LED Torch metalic body (24 Watt 4000 mAh)
24Supplying Gum Boots
25Supplying Cotton Duster
26Supplying Rubber Gloves
27Supplying Safety Cap
28Supplying Nails 4 inch
29Supplying Cable Holder Clamps
30Supply of 16 Amp Heavy Duty Extension board with 4 Socket
31Providing and Fixing Metal Clad Plug Screw locking type IP-54 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58471918
AUTHORITY Government Departments
TENDER VALUE 35 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Estimate For Electrical Fitting In P1 Tunnel Of Rsd Dam During Closure Works.
Basic Detail
Tender No 002/2026
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 11 Nov 2026
Submission Date 30 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 35 Lakhs
Tender Fee Ref. Documents
EMD 70000
Exemption Not Available
Document List
0c00f146-5084-4a13-86bb-ebdcdfdbc4af.html
BOQ_365931.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

0c00f146-5084-4a13-86bb-ebdcdfdbc4af.html

xls

BOQ_365931.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender