Tender For Repair And Renovation Of Office And Type Quarters Of Gopalpur Exploration Camp, Orient Area Of Regional Institute Vii, Bhubaneswar
Tender Value
1.20 Crore
Estimated cost
Bid Submission
02 Dec 2026
15 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jharsuguda → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Renovation Of Office And Type Quarters Of Gopalpur Exploration Camp, Orient Area Of Regional Institute Vii, Bhubaneswar
BOQ
| Sl. No. | Item Description |
| 1 | Removing dry or oil bound distemper, water proofing cement paint, enamel paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | 12 mm cement plaster of mix:1:4(1 cement: 4 fine sand) |
| 4 | Water proofing treatment on horizontal and vertical surface by applying two or more coat having a fiber-reinforced, elastomeric liquid waterproofing coating of upto 3-4 bars of positive waterproofing pressure on vertical surfaces and 5-7 bars of positive waterproofing pressure on horizontal surfaces, superior crack bridging abillity of upto 0.5mm-1mm on horizontal surface and flexibility with 150% elongation on horizontal surfaces. Two or more coat applied including cleaning of the surface as per instruction/approval of Engineer in charge. |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 6 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exteriorprimer applied @ 0.90 litre/10 sqm) |
| 7 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 8 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 10 | Providing and fixing on wall face PVC SWR pipes conforming to IS : 13592 , including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (In case SWR pipes is laid on ground, cost of trenching & filling, if required is to be paid separately) 110 mm diameter (Type B) |
| 11 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend |
| 12 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm shoe |
| 13 | Crack repair to walls by providing and fixing 10 mm dia reinforcement steel of 300mm length @500mm C/c along the crack after preparation of groove on the wall to place the reinforcement steel 10mm dia over which a chicken mesh of 150mm width along the entire crack length. after placing reinforcement steel and chiken mesh plaster(1:6) with water proofing compound shall be done. |
| 14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 15 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 16 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineerin-Charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 17 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 18 | Providing & fixing ISI mark flush door shutters conforming to IS:2202 (Part I) non-decorative type, coare of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : : 250x16 mm |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm |
| 21 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm |
| 22 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50metres lead :Of area 3 sq. metres and below |
| 23 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :15 mm to 40 mm nominal bore |
| 24 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below |
| 25 | Brick work with non modular fly ash lime bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 26 | Providing and laying in position excluding cement concrete of level: specified grade the cost ofcentering and shuttering - All work up to plinth1:1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 27 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 28 | Trimming of trees & cutting of dead part of trees in colony,near other structures etc and disposal of the same at an appropriate place as per instruction of Engg I/c. |
| 29 | Providing services for miscellaneous nature of unskilled work as per direction of Engineer-in-charge for a period of 8 hrs a day |
| 30 | Collection of garbage/debris from different places of office and disposal of the same at a suitable place as earmarked by Municipality/local authorities bysuitable mechanical arrangement (Tractor) including loading, unloading etc. Complete with all leads as per instruction of Engineer-in-Charge. (Tractor of 3.00 Cum capacity to be engaged at least twice in a week and no garbage shall be dumped in colony premises. Tractor trip in colony premises should be duly authenticated by concerned TA authorities. Garbage shall be covered properly and tied in order to avoid any slippage during transit).Note: Hire charge of tractor is inclusive of lead of 10 KM. The lead mayvary as per the requirement. |
| 31 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement: 3coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete Granite of any colour and shade |
| 32 | Providing and laying Vitrified tiles in diferent sizes (thickness to be specified by manufacturer), withwater absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours &shade, in skirting, riser of steps, over 12mmthick bed of cementmortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement &matching pigments etc. complete.Size of Tile 600x600 mm |
| 33 | Providing and fixing 1st quality ceramic glazed wall tilesconformingtoIS:15622(thickness tobespecifiedby themanufacturer),ofapprovedmake, inall colours, shadesexceptburgundy,bottlegreen,blackofanysizeasapprovedbyEngineer-in-Charge,inskirting,risersofstepsanddados,over12mmthickbedofcementmortar1:3(1cement:3coarsesand)andjointingwithgreycementslurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles. |
| 35 | Day to day maintenance of carpentry works by engaging one skilled carpenter and one unskilled Helper as per direction of EIC |
| 36 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid inrequired colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per thedirection of Engineer-in-charge. |
| 37 | Chequered terrazo tiles 22mm thick with graded marble chips of size up to 6mm in floors, jointed withneat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishingcomplete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Dark shade pigment using ordinary cement |
| 38 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) soliddoor/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of Kvalue 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miterjoints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N(Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 andresistance to spread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fastenersof required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SSdash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mmtolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profiledimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45 x 85 mm |
| 39 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screwwithdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with propertyof being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butthinges of required size with necessary full body threaded star headed counter sunk S.S screws, all asper direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shallbe paid separately)30 mm thick |
| 40 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 41 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701marked, with cover and suitable locking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support for tank. |
| 42 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia Pipes |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work 15 mm nominal outer dia Pipes |
| 46 | Providing CPVC ball valve of approved make as per direction of EIC 25 mm dia |
| 47 | Providing CPVC ball valve of approved make as per direction of EIC 20 mm dia |
| 48 | Providing PVC float valve for existing PVC water tank of make(Watertek/Supreme or equivalent) approved make as per direction of EIC |
| 49 | Demolishing cement concrete manually/ by mechanical means including disposal of material within50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 50 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 51 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 52 | Dismantling/Removing of APP as per instruction of Engineer in Charge: |
| 53 | Pruning, trimming, shaping of trees /shrubs (ht 15 feet and above) i/c removal of cut materials upto 50mt. Lead, as per direction of officer in charge. T&P shall be arranged by the contractor. |
| 54 | Supplying and fixing 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - |
| 55 | Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - |
| 56 | Supplying, erecting & marking DP MCB 63A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 57 | Supplying, erecting & marking DP MCB 40A , B- series in provided distribution board as per specification no. SWSWR/ MCB. CSR No.5-3-8 |
| 58 | Supplying and fixing 63 A , double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 59 | Supplying and fixing 40 A , double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 60 | Supplying and fixing 10 A rating, 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 61 | Supplying and fixing 16 A rating, 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 62 | Supplying and fixing 25 A rating, 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. |
| 63 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 64 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 65 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 66 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 67 | upplying and fixing 5 A piano type switch on the existing switch box/cover including connections etc. as required. |
| 68 | Supplying and fixing 3 pin 5/6 A socket outlet piano type socket on the existing switch box/cover including connections etc. as required. - 3 pin 5/6 A socket outlet |
| 69 | Supplying and fixing metal box of 180mm X 100mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections,painting etc. as required |
| 70 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 71 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 72 | Supplying and fixing of 3pin, 5 Amps Ceiling rose on the existing junction box/metal box including connection etc as required. |
| 73 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 74 | Supplying and fixing of 20 mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same incase of recessed conduit as required. |
| 75 | Providing and fixing 6 SWG dia GI. Wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ subnnain wiring/ cable as required. |
| 76 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 77 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender