Tender For Complete Erection Work Of 01 No. 132Kv & 01 No. 33Kv Feeder Bay For Additional 50Mva Transformer At 220Kv S/S Malanpur Under Testing Dn. I, Gwalior I
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Nov 2026
2 days left
EMD
22157
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhind → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Complete Erection Work Of 01 No. 132Kv & 01 No. 33Kv Feeder Bay For Additional 50Mva Transformer At 220Kv S/S Malanpur Under Testing Dn. I, Gwalior I
BOQ
| Sl. No. | Item Description |
| 1 | Erection of Structures :- Storage , shifting up to designated place , erection of structure & alignment , leveling and tightening , punching of nuts and bolts and its earthing etc.A. 132KV Structures :-1. 132KV CT Structures 03 Nos. 2. 132KV Gantry Beam 03 Nos. 3. 132KV Isolator Structures 3 Nos. 4. 132KV LA Structures 3 Nos. 5. 132KV Solid Core Structures 6 Nos. 6. 132KV Gantry Column 4 Nos.7. 132KV Main Bus Structures 2 Nos.8. 132KV Aux. Bus Structures 2 Nos. |
| 2 | Erection of Structures :- Storage , shifting up to designated place , erection of structure & alignment , leveling and tightening , punching of nuts and bolts and its earthing etc.B. 33KV Structures :-1. 33KV Main Bus Structures 1 No..2. 33KV Aux Bus Structures 1 No.3. 33KV CT Structures 3 Nos.4. 33KV PI Structures 3 Nos.5. 33KV Isolator Structures 1 No. 6. 33KV LA Structures 3 Nos.7. 33KV Gantry Column 2 Nos.8. 33KV Gantry Beam 1 No.9. 33KV Solid Core Structures 3 Nos. |
| 3 | Stringing of overhead Gantries ,vertical Droppers with ACSR Conductor including fixing of insulator string , spacer, clamps etc.A. Single Zebra |
| 4 | Stringing of overhead Gantries ,vertical Droppers with ACSR Conductor including fixing of insulator string , spacer, clamps etc.B. Twin Zebra |
| 5 | C. Screening Conductor/ overhead Shield wire :- Stringing of over head shield wire with 7/3.66 mm standard galvanized steel complete with fixing of strain clamp at the structures. |
| 6 | Unit rate of storage installation and erection of 132KV outdoor Equipments A. 132KV Circuit Breaker :- Shifting & placement of all the three Circuit Breaker poles on structure including shifting with in sub station premises complete assembly of Circuit Breaker including erection of mechanism box interconnecting piping work , erection of all accessories of the equipments & making interconnecting and its earthing. |
| 7 | Unit rate of storage installation and erection of 132KV outdoor Equipments B. 132KV CT :- Shifting & placement on structure fixing of junction box & all accessories making all interconnections etc. including its earthing. |
| 8 | Unit rate of storage installation and erection of 132KV outdoor Equipments C. 132KV Isolator without E/S (Three Phase) :- Shifting & placement of complete Isolator in all three phase of isolator on structure and its earthing along with mounting of mechanism box , interconnections piping , alignment of contacts and all accessories along with the application of petroleum jelly of jaws and contacts of isolators etc. |
| 9 | Unit rate of storage installation and erection of 132KV outdoor Equipments D. 132KV LA :- Shifting & placement of LA equipment on structure including all accessories making all interconnections checking and installation along with earthing etc. |
| 10 | Unit rate of storage installation and erection of 132KV outdoor Equipments E. 132KV Post/Solid Core Insulator :- Making all interconnection checking and installation along with Earthing etc. |
| 11 | Unit rate of storage installation and erection of 33KV outdoor Equipments A. 33KV Circuit Breaker :- Shifting & placement of all the three Circuit Breaker poles on structure including shifting with in sub station premises complete assembly of Circuit Breaker including erection of mechanism box interconnecting piping work , erection of all accessories of the equipments & making interconnecting and its earthing. |
| 12 | Unit rate of storage installation and erection of 33KV outdoor Equipments B. 33KV CT :- Shifting & placement on structure fixing of junction box & all accessories making all interconnections etc. including its earthing. |
| 13 | Unit rate of storage installation and erection of 33KV outdoor Equipments C. 33KV LA :- Shifting & placement of LA equipment on structure including all accessories making all interconnections checking and installation along with earthing etc. |
| 14 | Unit rate of storage installation and erection of 33KV outdoor Equipments D. 33KV Isolator without E/S (Three Phase) :- Shifting & placement of complete Isolator in all three phase of isolator on structure and its earthing along with mounting of mechanism box , interconnections piping , alignment of contacts and all accessories along with the application of petroleum jelly of jaws and contacts of isolators etc. |
| 15 | UNIT RATE OF UNLOADING , STORAGE , INSTALLATION AND ERRECTION , EARTHING AND FIXING OF GLANDS IN INDOOR EQUIPMENTS IN THE CONTROL ROOMA. 132KV C&R PANELS :- Storage , shifting of control & Relay panel and placements grouting of panel compete with all relay and there accessories and earthing and fixing of glands etc. making of all connection for the control & relay panel on terminal block as per drawing provided by EE Testing Dn.-I MPPTCL Gwalior including all AC & DC connections. |
| 16 | UNIT RATE OF UNLOADING , STORAGE , INSTALLATION AND ERRECTION , EARTHING AND FIXING OF GLANDS IN INDOOR EQUIPMENTS IN THE CONTROL ROOMB. 33KV C&R Panel (1T+2F) :- Storage , shifting of control & Relay panel and placements grouting of panel compete with all relay and there accessories and earthing and fixing of glands etc. making of all connection for the control & relay panel on terminal block as per drawing provided by EE Testing Dn.-I MPPTCL Gwalior including all AC & DC connections. |
| 17 | CABLE LAYING :- Laying of Copper cable (armored-un armored on racks/Cable Trays? Angle support overhead racks conduits including dressing of cable with accessories for Copper Conductor and unarmored Control cable. A. 2 Core x 2.5 Sq.mm |
| 18 | CABLE LAYING :- Laying of Copper cable (armored-un armored on racks/Cable Trays? Angle support overhead racks conduits including dressing of cable with accessories for Copper Conductor and unarmored Control cable. B. 4 Core x 2.5 Sq.mm |
| 19 | CABLE LAYING :- Laying of Copper cable (armored-un armored on racks/Cable Trays? Angle support overhead racks conduits including dressing of cable with accessories for Copper Conductor and unarmored Control cable. C. 8 Core x 2.5 Sq.mm |
| 20 | CABLE LAYING :- Laying of Copper cable (armored-un armored on racks/Cable Trays? Angle support overhead racks conduits including dressing of cable with accessories for Copper Conductor and unarmored Control cable. D. 12 Core x 2.5 Sq.mm |
| 21 | CABLE LAYING :- Laying of Copper cable (armored-un armored on racks/Cable Trays? Angle support overhead racks conduits including dressing of cable with accessories for Copper Conductor and unarmored Control cable. E. 19 Core x 2.5 Sq.mm |
| 22 | CABLE TERMINATION:-Cable Termination including providing of holes for Cable entry fixing of glands, dressing of Cable leads, fixing of lugs, etc. for each type of control cable including termination at both ends.A. 2 Core x 2.5 Sq.mm |
| 23 | CABLE TERMINATION:-Cable Termination including providing of holes for Cable entry fixing of glands, dressing of Cable leads, fixing of lugs, etc. for each type of control cable including termination at both ends.B. 4 Core x 2.5 Sq.mm |
| 24 | CABLE TERMINATION:-Cable Termination including providing of holes for Cable entry fixing of glands, dressing of Cable leads, fixing of lugs, etc. for each type of control cable including termination at both ends.C. 8 Core x 2.5 Sq.mm |
| 25 | CABLE TERMINATION:-Cable Termination including providing of holes for Cable entry fixing of glands, dressing of Cable leads, fixing of lugs, etc. for each type of control cable including termination at both ends.D. 12 Core x 2.5 Sq.mm |
| 26 | CABLE TERMINATION:-Cable Termination including providing of holes for Cable entry fixing of glands, dressing of Cable leads, fixing of lugs, etc. for each type of control cable including termination at both ends.E. 19 Core x 2.5 Sq.mm |
| 27 | Preparation of Earthing pits :- Preparation of Earthing pits ( 1.25MX1.25MX3M) as per Board's drawing No. XII-B- 774 which includes excavation of the soil encountered embedding of 4 Nos. G.I. pipes of size 40mm 3Mtr.long back filling with black cotton soil free from boulders & harmful mixture. These GI pipe are to be welded with MS flat at 3 places by making mesh frame and cutting of pipes as also making holes in pipe for water seepage. The earth pit is to be connected with earth mesh of MS flat. |
| 28 | Installation of earthlings’ :-Installation of following jointing up to the equipments earth terminals, fixing and clamping with accessories and hardware such as saddle, clamps, cleats, plugs, screws, nut bolts, washers & welding brazing etc. Installation of 25mm. Dia 3000mm. Long MS rod earth electrodes by directly driving / drilling (6'' dia) to in earth including excavation (irrespective of type of solid encountered) , back filling with bentonite soil, welding to earth Conductor etc |
| 29 | Installation of earthlings’ :-Installation of following jointing up to the equipments earth terminals, fixing and clamping with accessories and hardware such as saddle, clamps, cleats, plugs, screws, nut bolts, washers & welding brazing etc. Laying of Flat (65mmx or 50mmx6mm) duly buried at a depth of 0.5 Mtr. providing of risers for structures earthing including back filling, welding etc. structures earthing of following length.A. 50X6mm |
| 30 | Installation of earthlings’ :-Installation of following jointing up to the equipments earth terminals, fixing and clamping with accessories and hardware such as saddle, clamps, cleats, plugs, screws, nut bolts, washers & welding brazing etc. Laying of Flat (65mmx or 50mmx6mm) duly buried at a depth of 0.5 Mtr. providing of risers for structures earthing including back filling, welding etc. structures earthing of following length.B. 65X8mm |
| 31 | Installation of Lighting Fixture :- Installation of light fixture on gantry column , supply connection to the light fitting from the nearest lighting board in the yard etc. |
| 32 | Junction Box (01 No. 36 Ways & 01 No. 64 Ways) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender