Tender For Water Proofing Treatment To Reinforced Cement Concrete Roofs In Estate Of Area At Ofmk.
Tender Value
49 Lakhs
Estimated cost
Bid Submission
24 Nov 2026
4 days left
EMD
98000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sangareddy → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Water Proofing Treatment To Reinforced Cement Concrete Roofs In Estate Of Area At Ofmk.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work if cement concrete is reinforced (reinforcement cut as required to facilitate demolition). Complete all as specified and directed by EIC. |
| 2 | Taking down cement plaster of any description on brick/stone/ concrete wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. Complete all as specified and directed by EIC. |
| 3 | Rendering of 15 mm thick plastering with 1:3 cement mortar on fair faces of brick work or concrete surfaces by adding polymer based admixure. Complete in all respects as directed. |
| 4 | Providing, cement concrete Type B1 1:2:4 using 20 mm graded aggregate in roof kerbs, mud stops, rounded or chamfered on edges. |
| 5 | Cement concrete type B-1, 1:2:4 (20mm graded aggregate) in slab floors etc. 40 mm thick |
| 6 | Brick work : Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar. Complete all as specified and directed |
| 7 | Cutting or uprooting grass on old CC/brick tiles or on old mud phuska, removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. |
| 8 | Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coat with lndustrial bitumen 85/25 for waterproofing treatments at the rate of 1.2 kg / sqm . |
| 9 | Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced application by torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm. Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. |
| 10 | Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. |
| 11 | Micro concrete : Repairs to the substrate, cutting of cracks, filling of blowholes/voids and surface leveling must be carried out using appropriate acrylic bonding agent and filling the same with microconcrete of compressive strength 50 N/mm2 and curing the surface with wax based curing compound as per the Engineer-in-charge instructions. |
| 12 | Supply and application of one coat of water proofing anticorrosive paint with aluminium finish, composed of oxidised bitumen, volatile solvents and specially formulated aluminium compound. Make . STP / Asian / Birla. |
| 13 | Demolition and removal of old tarfelt / APP membrane matting single or double any type including supports, cover fillets if any. as directed. . |
| 14 | Polyurethane water proof (Applicaton only) coating on terraced roofs : Preparation of CC/brick tiled surface mechanically or by grinding to make its smooth. Repair of all cracks & cuts if any before application of water proofing coat by cutting “V” groove and fill with PMC mortar. Slightly damp the surface and avoid standing water / ponding.Application of Single component polyurethane based primer. Application of water proofing polyurethane liquid membrane STP ShaliUrethane BTD 1.0 mm thick in two coats. Complete in all respects as directed and as per the instructions of authorised material supplier. |
| 15 | Supply only of STP Shali Urethane BTD a polyurethane liquid membrane or equivalent of STP/ fosroc/sika. |
| 16 | Supply only of Shaliprime PUM an epoxy primer tobe applied over terrace after filling of groovesor equivalent of STP/ fosroc/sika |
| 17 | Supply of SBR Latex admixure for mixing in CM 1:3 for groove filling and curing or equivalent of STP/ fosroc/sika Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender