Tender for Carrying Out Extensive Repairs Of Various Buildings At Aiesl, Engineering Premises, Oap, Mumbai-400 029
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. as required, all complete as per the direction of the Engineer-in-charge. |
| 3 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 4 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) |
| 6 | Providing and fixing glazing in aluminium windows, ventilators and partion etc. EPDM rubber/ neoprene gasket etc. as per specifiactions, drawings and direction of engineer in charge.(cost of aluminium snap beading shall be paid basic item)with float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm |
| 7 | Removing of existing flooring tiles/marble for the repair works |
| 8 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 500x500 mm |
| 9 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 10 | Structural RepairsCleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 11 | Bars upto 12 mm diameter |
| 12 | Bars above 12 mm diameter |
| 13 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. Upto and including 12 mm dia. |
| 14 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer- In-charge complete in all respect. including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 15 | Providing and applying rust inhabitation coat/system to exposed reinforcement bars and also new reinforcement bars after removing scales and rust complete as per specification. Providing and applying bond coat to all exposed concrete surface and reinforcement bars prior to any treatment as per specification. Providing and applying single component, fiber reinforced, thixotropic repair mortar of average thickness 50mm and above of \\"'BASF\\" (MASTER EMACO 348 S)/ or equivalent as manufacturer's specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc.including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 16 | Providing and laying/ pouring in position/ location SMC (Self leveling micro concrete) RENDRC RGL or equivalent as directed or as approved by EIC, mixing with specified quantity of water as recommended by the manufacturer including cutting the existing concrete floor to shape with cutting machine only, dismantling the existing concrete floor, cleaning the surface with water, taking rubbish out of AIESL premises, applying bond coat of RBR or equivalent and cement in proportion 1:1 including necessary approved centering and formwork, finishing top as directed including labour , tools plants etc complete. |
| 17 | Steel Reinforcement for RCC Work includuing straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo- Mechanically Treated bars of grade FE500D or more |
| 18 | EXTERNAL CEMENT PLASTER IN TWO COATS18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.Note: No extra payment shall be made for extra thickness of plaster carried out to match with existing surface. |
| 19 | INTERNAL CEMENT PLASTER IN TWO COATS18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.Note: No extra payment shall be made for extra thickness of plaster carried out to match with existing surface. |
| 20 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even smooth complete. including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 21 | Finishing walls with acrylic smooth exterior paint of required shade. Old work (one or more coats applied @ 1.67 kg/10 sqm) over and pincluding priming coat of exterior primer applied @ 0.90 liter/10sqm |
| 22 | Distemparing with 1st quality acrylic distemper (ready mixed) having VOC (volatile organic compound ) content less than 50 gram/litre of approved brand nad manufacturer including applying additional coats wherever required to achieve even shade and colour. old work (one or more coats). |
| 23 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work. |
| 24 | Providing & applying two coats of Acrylic Elastomeric Exterior Waterproofing compound of “Dr. Fixit Raincoat” or equivalent approved make and one coat of approved priming coat asper the waterproofing coating manufacturer to vertical wall surfaces at any level and location including scaffolding etc. complete, as per instruction of the Engineer in Charge. |
| 25 | Plumbing and sanitation WorksProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. External work |
| 26 | 15 mm nominal dia Pipes |
| 27 | 20 mm nominal dia Pipes |
| 28 | 25 mm nominal dia Pipes |
| 29 | 32 mm nominal dia Pipes |
| 30 | 40 mm nominal dia Pipes |
| 31 | 50 mm nominal dia Pipes |
| 32 | 65 mm nominal dia Pipes |
| 33 | 80 mm nominal dia Pipes |
| 34 | Providing and fixing PVC rain water pipe of ‘’Prince’’ or equivalent approved make conforming to IS 13592 of SWR quality 4 kg/cm2 pressure rated, at any locations and at all levels, scaffolding etc. including all PVC fittings like bands, shoes, clamps, supports etc. jointing with rubber ring/ solvent cement, leak proof adhesive etc. cutting and making good the walls and floors etc. complete. As per instruction of rain water pipe manufacturers ND EIC. 150 mm dia with PVC clamps including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 35 | Providing and fixing PVC downtake pipe of ‘’Prince’’ or equivalent approved make conforming to IS 13592 of SWR quality 4 kg/cm2 pressure rated, at any locations and at all levels, scaffolding etc. including all PVC fittings like bands, shoes, clamps, supports etc. jointing with rubber ring/ solvent cement, leak proof adhesive etc. cutting and making good the walls and floors etc. complete. As per instruction of rain water pipe manufacturers ND EIC. 100 mm dia with PVC clamps including scaffolding at any level and location etc. & disposal of rubbish to the dumping ground within 50 metres lead. |
| 36 | Providing and fixing in position Hindware make Indian style WC pan including making inlet/outlet connections and consists of the followingi) White colour Orissa pan 580 x 440 mm size open rim of approvedmake, ii) Porcelain P or S trap with vent pipe, iii) 100 dia C.I.connector pipe from P or S trap to the junction of soil stack onexternal face of building.etc. complete.(White color Orissa WC Model No. 20004). OR consider equivalent make. |
| 37 | Providing and Fixing of PVC 4\\" dia nahani trap of ‘’Prince’’ or equivalent approved make conforming to IS 13592 in WC, Bath Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender