Tender For Annual Repair And Maintenance Of 13 Nos. Bops (Tungi, Khajibagan, Banpur, Matyari, Ambagan, Gede, Halderpara, Vijaypur, Govindpur, Bishnupur, Kadipur, Harandipur And Maluapara) Buildings In Aor Of 32 Bn Bsf For Fy 2026-27 Under Shq Bsf Kri
Tender Overview
Project Description
Tender for Annual Repair And Maintenance Of 13 Nos. Bops (Tungi, Khajibagan, Banpur, Matyari, Ambagan, Gede, Halderpara, Vijaypur, Govindpur, Bishnupur, Kadipur, Harandipur And Maluapara) Buildings In Aor Of 32 Bn Bsf For Fy 2026-27 Under Shq Bsf Krishnanagar.(Sh : Electrical Work).
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire |
| 5 | 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire |
| 6 | 2 x 4 sqmm + 1 x 4 sqmm earth wire |
| 7 | 2 x 6 sqmm + 1 x 6 sqmm earth wire |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 20 mm |
| 12 | Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required |
| 13 | 5/6 amps switch |
| 14 | 15/16 A switch |
| 15 | 3 pin 5/6 A socket outlet |
| 16 | 6 pin 15/16 A socket outlet |
| 17 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 21 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 23 | supplying and fixing following way double door single pole and natural MCB distribution board 240 volt on surface/recess complete with tinned copper busbarm neutral busbar, earth bar, din bar, detachable gland plate, interconnections , phosphatized and powder painted including earthing etc as required (But without MCB/RCCB/Isolator) |
| 24 | 6 way, Double door |
| 25 | 8 way, Double door |
| 26 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of connections, testing and commissioning etc. as required. |
| 27 | Single Pole |
| 28 | Double pole |
| 29 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 30 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation andre-filling as required |
| 31 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 32 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).(i) 50 Watt |
| 34 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. (i) 12 - 15 Watt |
| 35 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (i) Upto 35 sq mm |
| 36 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 37 | Providing and laying/fixing G. I. pipe of 40 mm dia (medium duty) for protection of UG cable of ISI marked. |
| 38 | Supplying & fixing of 20/22 watt 4 feet energy effiecient LED tube light(batten) directly on wall suitable for single phase AC 230 V complete with accessories connection etc as required. |
| 39 | Supplying & fixing of 9/10 Watt, 6500K environmental friendly, energy efficient, LED batten(Mirror light) directly on ceiling/ wall, including connections etc as required. |
| 40 | Supplying, Installation, testing and commissioning of ceiling fan 1200mm sweep ISI mark single phase 230v 50HZ and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 41 | Supplying and fixing of 380 mm sweep, heavy duty 900 RPM, metallic exhaust fan suitable for single phase, 50 Hz, 230 volts, AC supply in existing hole including fixing of louver/shutter connection, testing etc. as required. |
| 42 | Supplying and fixing electronic fan regulator (socket type piano) on the existing switch box including connections etc. as required. |
| 43 | Supplying and fixing four pole sheet steel enclosure on surface/recess along with 63 A 415 V, \\"C\\" curve FP MCB complete with connections, testing and commissioning etc. as required. |
| 44 | Supplying and Laying of one number XLPE insulated PVC sheathed power cable of 1.1 KV grade of 2 x 16 sqmm size Aluminum armoured cable direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 45 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 2 x 16 Sqmm size in the existing PVC/ METAL pipe/open as required. |
| 46 | Add cost index @9% on DSR items i.e 01 to 18 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender