Tender For Special Repair Replacement Of Lightning Protection System At Various Buildings At installation Kardip, Kamorta And Provision Of Synchronization Panel For 2X160 Kva Ncn Dg Sets At installation Kardip, Kamorta. 8850/E8
Tender Overview
Project Description
Tender for Special Repair Replacement Of Lightning Protection System At Various Buildings At installation Kardip, Kamorta And Provision Of Synchronization Panel For 2X160 Kva Ncn Dg Sets At installation Kardip, Kamorta. 8850/E8
BOQ
| Sl. No. | Item Description |
| 1 | Supply & fixing in repair single pointed Air termination rod, single pointed, aluminium rod 12mm dia and 300mm long complete all as specified & directed |
| 2 | Supply and fix in repair aluminium strip 25mmx3mm complete with saddles epoxy base and fixing screws for fitting the strip for roof conductors and down conductors above ground complete all as specified and directed. |
| 3 | M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x4mm galvanised iron strip including taking up the old unserviceable strip, complete all as directed by Engr-in-charge. |
| 4 | Supply & Fix in repair 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. |
| 5 | Supply & fixing in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed |
| 6 | Dismantiling and taking out old unserviceable earthing and Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(2009)Note: Unit rate quoted shall be deemed to be included the following (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 7 | Design, manufacturing /fabrication, supply, installation testing and commissioning of synchronization / AMF panel suitable for synchronising 2 DG sets of capacity all 160 KVA to share electric load as per load demand ) Cubical panel board of suitable size(proper space shall be provided for working in each compartment), 3 Phase 4 wire system indoor type 2.0mm , separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable 3.5 Core in and out, incoming and outgoing feeders duly marked on riveted plates etc, indoor type, double door, cubical type, pedestal mounted, of suitable size, CPRI approved having, IP 65, independent compartment for bus bar, incoming feeder and each out going feeders, totally dust and vermin proof with front and rear openings & lockable, factory made, fabricated out of 2 mm thick CRCA Sheet confirming to IS 8623 duly treated through 7 tank pre-treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structural RAL 7032 shade colour & MS angle iron section of 50X50X6 mm frame, built in industrial type locking arrangement on front and back and suitable for 3 Phase 415 volts 50 Hz, AC supply 415/440, 3 phase, 4 wire AC 50Hz having copper bus bar capacity required to carry current 110% load with three phase and half neutral colour coded, prewired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved copper strip for connecting switchgears, all as standard practice of manufacturer specifications comprising of following all as specified and as directed |
| 8 | a) Power cables incoming/outgoing/Bus bars / Control cables as recommended by OEM are included.(b) SMC/DMC insulators (c) Air circuit breakers MDO type capacity 800 Amps(d) Synchronisation relays in all incomings, differential protection relays, master trip circuit relay, trip circuit supervision relays, voltage protection relays and other engine & alternator control and prection equipment’s on all incomings.(e) CTs & PTs, metering equipment, CT shoot terminals other misc. accessories(f) Modification needed in DG circuit, control panel, alternator, existing panel are included as required.Note: PCC in 1:2:4 typeB1 using 20mm graded stone aggregate for foundation and platform ofsuitable size is deemed to be included with quated rate. |
| 9 | 1X160 KVA DG Set Incomer including following accessories of each feeder :-02 Nos1. MCCB 250 A, 4P, 36KA MP based protection release with O/C, S/C. LSIG protection- 01 No2. Extended rotary handle- 01No3. Spreader terminal-set of 3- 02 No4. Power contactor, 3p, 250A AC1 duty- 01 No5. Neutral contactor, 3P, 45A AC1 duty- 01 No6. 2NO+2NC Aux. contact block- 02 No7. MCB 6 A, SP, ICU=10 KA, C- curve- 01 No8. MCB 6 A, DP, ICU=10 KA, C- curve-01 No9. MCB 16 A, DP, ICU=10 KA, C- curve- 01 No10. Selector switch 6A, 2 pole 2 way middle OFF- 01 No |
| 10 | 11. LED Red, 230 VAC, cluster LED type- 01 No12. LED Yellow, 230 VAC, cluster LED type- 01 No13.LED Blue, 230 VAC, cluster LED type- 01 No14. LED Red, 230 VAC, cluster LED type- 01 No15.LED Green, 230 VAC, cluster LED type- 01 No16. Led Amber, 24 VDC, cluster LED type- 01 No17. Push button actuator Green, flush head type with 1NO contact block - 02 No18. Push button actuator Red, flush head type with 1N contact block- 02 No19. Emergency push button- 01 No20. Multifunction meter V A F PF, KW, Energy, KVA, KVAR, KVARH, KVAH, Run & ON hours, RPM, % unbalance, THDBEZEL: 96 X 96, LED display- 01 No21. CT 250/5A, 5VA, class: 1.0, tape wound- 03 No |
| 11 | 22. Aux contactor 4NO, 24v DC- 02 No23. Aux contactor 2NO+2NC, 24V DC- 08 No24. Aux contactor 2NO+2NC, 220V AC- 02 No25. Add ON block 2NO+2NC- 04 No26. Add ON block 4NO- 02 No27. Synchronizing relay 24v DC power, with inbuilt OV, UN, SC, and OC DG protection. (Easygen-2000 series)- 01 No28. Voltmeter (DC)- 01 No29. Ammeter (DC) - 01 No30. Battery charger 24V DC power 20A - 01 No31. Voltage monitoring relay with 2C/O relay - 01 No32. Hooter-24V DC - 01 No |
| 12 | OUTGOING 400A 4 Pole MCCB including following accessories - 1 Nos1 400 Amps MCCB 4 Pole2 Voltmeter (DC)- 01 No3. Ammeter (DC) - 01 No4. LED Red, 230 VAC, cluster LED type- 01 No5. LED Yellow, 230 VAC, cluster LED type- 01 No6.LED Blue, 230 VAC, cluster LED type- 01 No7. LED Red, 230 VAC, cluster LED type- 01 No8.LED Green, 230 VAC, cluster LED type- 01 No9. Led Amber, 24 VDC, cluster LED type- 01 No |
| 13 | PLC BASED Synchronising & AUTO LOAD SHARING1. ComAp Synchronizing controller ComAp InteliVision Color Display InteliField Bus GatewayComAp make InteliGen4 200 DG controller ComaAp 3.02. PLC for Interlocking Delta 1.03. SMPS 24V, 4 Amp GIC 1.03. 8 Channel Relay Card 230V AC UL 3.04. VMR GIC 1.05. Aux Contactors 2 No 2 NC 230V AC L&T 5.06. Add on Block 2 No 2 NC 24V DC L&T 2.07. 16A DP MCB L&T 3.08. 12/24V, 10 Amp DC Battery Charger PCS 3.09. UPS 650 KVA Microtech 1.010. Cooling Fan 6\\" Rexnord 4.011. Space Heater with Thermostat Reputed 4.012. DG Start/Stop Push Button Esbee 6.013. Auto/Manual Operated Salzer 3.014. Terminal Block - Lot |
| 14 | GENERAL ITEMS:Steel Fabricated Body made out of 2/1.6 mm Thick CRCA Sheet Steel duly Powder Coated ITE 1.02. Alu. Bus bar 600A with Support duly Heat shrinkable PVC sleeved, Hindalco Lot3. Hardware & Accessories Reputed Lot4. PVC wiring RR Cabel Lot5. Programming ITE |
| 15 | Schedule of Credit (Minus) Rs.13670.00 NOTE: Bidder shall insert credit amount of Rs.13670.00 as rate in Green field under Col-13. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender