Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58469349

Tender For Repair/Maint Of Lt/Ht Cable Network, Transformers, Lt Switch Gears/Acbs, Ht Switch Gears/Vcbs And Connected Items At Zone-Ii Under Age E/M Of Ge Jaipur

Issued by Statutory Bodies & Commissions/Committees · Jaipur, Rajasthan
Tender Value
42 Lakhs
Estimated cost
Bid Submission
03 Dec 2026
21 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Lt/Ht Cable Network, Transformers, Lt Switch Gears/Acbs, Ht Switch Gears/Vcbs And Connected Items At Zone-Ii Under Age E/M Of Ge Jaipur

BOQ

Name of Work:- REPAIR/MAINT OF LT/HT CABLE NETWORK, TRANSFORMERS, LT SWITCH GEARS/ACBs, HT SWITCH GEARS/VCBs AND CONNECTED ITEMS AT ZONE-II UNDER AGE E/M OF GE JAIPUR
Sl. No. Item Description
1Item Rate BoQ 82603/E8 BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CWE JAIPUR Name of Work: REPAIR/MAINT OF LT/HT CABLE NETWORK, TRANSFORMERS, LT SWITCH GEARS/ACBs, HT SWITCH GEARS/VCBs AND CONNECTED ITEMS AT ZONE-II UNDER AGE E/M OF GE JAIPUR CA NO: CWE/JPR- OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # SNo Item Description Item Code / Make Qty Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figure Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes Rate in Words Total Amount
2M & L for Proper alignment of indoor MH substation LT panels,including arrangement and fixing of panels at a suitable height using 40x40x6mm angle iron supports,including Proper termination of all cables with suitable cable lugs,Removal of all dead/unused cables from the substation trench and cleaning of cable trench to ensure safe and neat cable routing complete all as specified and directed.
3Dismantling of cross arms / bracing supports / clamps / back plates or any other structural steel sections including removing nuts bolts washers etc complete all as specified and directed.
4M&L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed.
5S&F in repairs pin type insulator porcelain vitreous white / brown / green including one galvanised mild steel spindle, two galvanised iron washers, one galvanised iron nut, suitable for 11000 volts grade & of size 150 mm dia and 150mm height complete all as specified and directed.
6Dismantling & taking down old, deteriorated, switch air break and supply and fixing switch air break gang operated triple pole mechanically operated horizontal/vertical type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps horizontal type suitable for 11000 V. grade complete all as specified and directed.
7Dismantling & taking down old, deteriorated, dropout fuse assembly and supply and fixing dropout fuse assembly with two insulators including HT fuse as per existing rating,suitable for 11000 V grade complete all as specified and directed.
8Material and labour for Servicing 2 Pole HT Structure including cleaning, greasing, rejumpering, replacement of corroded Nuts, bolts etc and cleaning greasing of Gang operating device and keeping good of each structure in proper working conditions complete all as directed by the Engineer-in-Charge (Note :- The quoted rate is inclusive of almn conductor for jumperring, fuse wire of suitable amp & petrolium gelly for servicing and other required items )
9M & L for trimming/cutting the tree branches/ bushes around the HT over head 4 pole structure and making safe clearance up to 4.00 metre distance from line wire all as directed by Engineer-in-Charge.
10M&L of checking of HT 11 KV cable of any size by means of HT Cable Fault Locator Machine for identifying fault location in HT cable faults complete all as specified and directed.
11S&F in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size from 95 sqmm complete all as specified and directed by the Engineer - in - Charge.Note: Excavation and earthwork included in quoted rate.
12S&F in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by the Engineer - in - Charge. Note: Excavation and earthwork included in quoted rate.
13S&F in repair cable joint kit for 11 KV grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size1 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge. Note: Excavation and earthwork included in quoted rate.
14S&F in repair cable joint kit for 11 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size from 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge.Note: Excavation and earthwork included in quoted rate.
15S&F in repair Cable joining kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed by the Engineer - in - Charge. Note: Excavation and earthwork included in quoted rate.
16S&F in replacement 11000 volt grade heavy duty HT XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 185 Sqmm nominal cross section 3 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
17S&F in replacement 11000 volt grade heavy duty HT XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 120 Sqmm nominal cross section 3 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
18S&F in replacement 11000 volt grade heavy duty HT XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 95 Sqmm nominal cross section 3 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
19S&F in replacement GI tubing light grade 80 mm dia for /pole cable protection including fixing clamp, nut bolt washer complete accssories complete all as specified and directed.
20M&L for manual Boring of holes under road, pavement, hard standing complete all as specified and directed by Engineer-in-Charge.
21M&L in replacment GI pipe Light grade with all fittings complete laid in trenches/fixed on pole with suitable clamp all as specified for 100 mm bore of pipe for protection of UG cable complete all as specified and directed.
22Dismantling & taking down old, deteriorated, lightening, arrestor and supply and fixing testing litghtening arrestor Expulsion out door type discharge current 10 KA assembly suitable for 12 KV including all clamps ,nuts, bolts and washers and connection to earth with 32 x 6 mm GI strip and including expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Voltrs complete all as specified and directed.
23M&L in replacement danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 KV of size 25 x 20 cm complete all as specified and directed.
24Material & labour for earthing complete with copper earthing electrode 60cmx60cmx 3.15mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip of 20x3mm, by means of nuts, bolts, check nuts and washer etc, made of copper and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. Complete all as specified and directed.NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately
25Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore light grade GI protection pipe, test point etc. complete all as specified and directed.NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
26S&F in repairs heat shrink right angled boots for XLPE 11 KV 120 to 185 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers.
27M&L for opening up the top cover of transformer of any capacity for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable containers (containers to be provided by the contractor) and repair the transformer with replacement of parts where required, check the lead connection from winding to bushing rods including necessary soldering/jointing etc and refilling the dehydrated oil after complete repair, making all connections and testing on full load complete all as specified & as directed.Notes :-(i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item.(ii) Major parts where required to be replaced shall be measured and paid for separately as ‘Supply only’ under relevant items of this Schedule.(iii) All T&P and minor parts such as nuts, bolts, washers, insulating material, copper wire for delta connection, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item.(iv) Dehydration of existing transformer oil and new transformer oil required for topping up shall be measured and paid for separately under relevant items of this Schedule.
28M&L for disconnecting existing transformer step down 11 KV/0.433 KV indoor/outdoor type of capacity 200 KVA, taking down from site of installation, opening the top cover of transformer, draining out transformer oil from the housing in suitable containers (containers to be provided by the contractor) and deposit the oil in store yard of AGE E/M, inspecting / assessing the defective / burnt parts, core assembly, etc in the presence of Engineer-in-Charge, shifting the transformer to workshop for repair including loading, unloading, transportation etc, cleaning and making good surface including internal cleaning, removing sludge, etc and painting with one coat of zinc chromate paint to the inner side of the transformer body and one coat of synthetic enamel paint (grey) on outer body of transformer by using spray machine after cleaning & removing oil spots etc, carrying out necessary repair to transformer at workshop, re-assembling, shifting back to site, reinstalling, re-connecting, re-commissioning the transformer and testing at site on full load, complete all as specified and as directed.
29,---Ditto--- all as per item no 27 above but for Transformer of capacity 315 to 400 KVA complete.
30Supply only the following spares/items for repair/replacement to transformers under serial item No. 27.00 to 28.00 here-in-before :-(a) LT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer complete all as directed.
31(b) HT coil made out of super enameled copper conductor wire of suitable gauge and size as per requirement for distribution transformer complete all as directed.
32M&L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV all as directed by Engineer-in Charge. Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive as above.(ii) Contractor will submit before & after testing report of transformer oil.
33S&F in replacement of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by engineer -in- charge.
34M&L for replacement of defective silica gel breather assembly with silica gel complete set upto 400KVA all as directed by Engineer-in-Charge
35M&L for replacement of LT bushing of brass with neoprene rubber bush for Transformer upto 400KVA capacities all as directed by Engineer-in Charge.
36M&L for replacement of HT bushing of brass with neoprene rubber bush for Transformer upto 400KVA capacities all as directed by Engineer-in Charge.
37Supply and laying stone aggregate of size 40mm to 63 mm graded laid on ground around of two/four pole structure complete all as specified and directed.Note : i) Contractor will do preparation/leveling of the area before spreading of gravel in such a way as to clear of all grass, weeds, roots and all other objectionable materials. (ii) A suitable chemical treatment on the switchyard ground shall be applied to arrest future growth of grass, weeds, etc. as per Engineer-in-Charge.(iii) The first layer of lower size aggregate shall be spread uniformly and compacted to a thickness of approximately 50 mm.(iv) The second layer consists of 63 mm and 40 mm size aggregates mixed in proportion of 2:1 by volume, which shall be spread uniformly and compacted to the thickness of approximately 100 mm, so as to furnish a total finished thickness of 150 mm of compacted gravel surfacing.(v) Aggregate shall consist of well-shaped clean, arid, dense, durable granite rock fragments and shall not include elongated, flaky or laminated pieces and any other impurities or deleterious material.(vi) Rate of cleaning grass/chemical treatment/compacting/any other connected material and labour is included in unit rate quoted above.Note: For the payment of loose aggregate a deduction @ 12.5% shall be made from the net measured quantity.
38Supply only Gasket set made of rubberised cork/neoprene material for transformer of capacity upto 400 KVA complete all as specified and as directed.
39M & L for area cleaning/sweeping of preimises and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees n exc 15 cm girth (measured one metre above ground level) and maintaining the ground surrounding transformers, LT Panels, 02 Pole structures, 04 Pole Structures, etc at various sub stations / E&M installations and removing the same out side the defence area as directed by Engr in charge.
40M&L for Repair and maintanance of 11 KV HT RMU indoor/outdoor type, EACH WAY of RMU 400/630/800 Amp rating from HT Panel after switching off electric supply. Removal of all the possible mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, indication system, including checking the quality of insulating material, complete & refixing with faulty part replaced blowing out dust and applying the proper lubrication/ greasing and reassembling the including motorised operation and connection to HT panel & before filling of gas leakage testing carried out (if quantity is lesser than required) and make the RMU functional to the entire satisfaction and as directed by the Engineer-in-charge. Notes :- (i) The RMUs are installed at MH, RMU are of different type of makes installed at site like Crompton Greaves, Alstom, Areva, Schneider,Siemens,C&S, etc. (ii) Spare parts if replaced & Gas if filled shall be measured and paid separately under respective items supply only .
41Material & labour for Repair and maintanance of relay set (O/C and E/F relays) of any make for 11KV VCB/RMU panel, removing and refixing (the contacts NO+NC should be cleaned by CTC solution and adjust if electromagnetic) with faulty part replaced and calibrate the relays by relay testing kit & proper setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by Engr-in-charge. Notes :- (i) Testing shall be carried out by primary and secondry injection kit. (ii) Spare parts shall be measured and paid separately under supply only. (iii) The tripping system should be in accordance with the incomer of the affected feeder and setting should be maintained such that fault does not carry beyond the particular feeder due to overload, 3 phase fault, earth fault etc.(iv) The VCBs/RMUs are installed at MH and VCBs are of different type of makes installed at site like Crompton Greaves, Alstom,Schneider, Ashida, Siemens,L&T, C&S or any other of relays available on the site.
42Material & labour for Repair,Maitainance & Servicing of 11KV HT OCB indoor/outdoor type complete including the following (a) Taking out 11KV HT OCB of 400/630/800 Amp rating trolley from HT Panel after switching off electric supply. Removing all mechanical/electrical/control system for proper functioning e.g. spring charge system, triping system, remote operation, indication system, upward-downward/in-out movement of HT OCB trolley,etc including opening the OCB trolly & checking the quality of insulating material,vaccum system complete. Replace defective parts, fixed/ moving contacts and blowing out dust and applying the proper lubrication/ greasing with AP-3 grease and reassembling the OCB including connection to HT panel and make the OCB functional to the entire satisfaction of and as directed by the Engineer-in-charge.
43Supply & fixing in repairs HT 11 KV HRC fuse 63 amp complete all as specified by engr in charge.
44Supply only CTC solution bottle.
45Supplying and laying Synthetic Rubber insulated mats 2.5mm thick for voltage Upto 11KV for electrical purpose as per IS15652-2006 (Superseding IS 5424) suitable for electric shock safety of sizes 2M X 1M.
46M&L for taking out old unservicable LT cable of any size from trenches complete all as specified and directed
47S&F of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
48S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
49S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
50S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
51S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers completeas directed
52S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers completeas directed
53S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
54S&F of XLPE insulated, armoured heavy duty electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
55S&F of XLPE insulated, armoured heavy duty electric cable laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
56S&F of XLPE insulated, armoured heavy duty electric cable laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
57S&F of XLPE insulated, armoured heavy duty electric cable laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 Core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete as directed
58Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed
59Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
60Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
61M & L Sand cushioning to under ground cable with screened and washed sand (non cohessive), 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge.Note : Punned thickness shall be considered for payment purpose.
62Supplying and laying un-reinforced precast cable covers class HV, type I, flat, size 300mm x 180mm x 40mm.
63Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
64M&L for replacement of digital voltmeter of suitable range including wiring with copper conductor cable of suitable size all as specified and as directed by Engineer-in-Charge.
65M&L for replacement of digital ammeter of suitable range including wiring with copper conductor cable of suitable size all as specified and as directed by Engineer-in-Charge.
66Repair, maint and general servicing of existing LT panel/LT feeder pillar including,painting of panel dual coat of enamel paint including replacement of brunt Lugs and insulation of bus baars ,rewiring of LT panel including all accessories,cleaning of LT panel ,welding of LT panel to its angle iron frame,other PCC related work ,hinjes replacement,locking arrangement and all other small maint work like marking of LT feeders with synthetic enamel paints as directed by engineer in charge
67S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 25 to 50 sqmm complete all as specified and directed.
68S&F in replacement of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 70 to 120 sqmm complete all as specified and directed.
69S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 150 to 185 sqmm complete all as specified and directed.
70S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 240 to 300 sqmm complete all as specified and directed.
71S&F in repair of cable jointing kit for 1100V grade cable for straight through heat shrink type joint complete jointing material & accessories suitable for 3.5 core XLPE armoured aluminium condctor of size 400 sqmm complete all as specified and directed.
72S & F Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 16 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
73Ditto All as per Srl item No . 71 here in above but 70 Sqmm to 120 sqmm 3.5 Core
74Ditto All as per Srl item No . 71 here in above but 150 Sqmm to 185 sqmm 3.5 Core
75Ditto All as per Srl item No . 71 here in above but 240 Sqmm to 300 sqmm 3.5 Core
76Ditto All as per Srl item No . 71 here in above but 400 sqmm 3.5 Core
77Supply and fixing in repair of MCCBs of following sizes:-(a)MCCB 400 Amp 4 pole 415 V ,36KA thermal megnatic adjustable type
78(b) MCCB 250 Amp 4 pole 415 V,25 KA thermal megnatic adjustable type
79(c) MCCB 200 Amp 4 pole 415 V,25 KA thermal megnatic adjustable type
80(d) MCCB 160 Amp 4 pole 415 V,16 KA thermal megnatic adjustable type
81(e) MCCB 125 Amp 4 pole 415 V,16 KA thermal megnatic adjustable type
82(f) MCCB 100 Amp 4 pole 415 V,16 KA thermal megnatic adjustable type
83(g) MCCB 63 Amp 4 pole 415 V,10 KA thermal megnatic adjustable type
84(h) MCCB 630 Amp 4 pole 415 V ,50KA thermal megnatic adjustable type
85(i) MCCB 32 Amp 4 pole 415 V,10 KA thermal megnatic adjustable type
86Supply and fixing in repair of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps,DMX SP-Icu=lcs 50 KA,compact dimention ,in built temperature protection (50-100%), (Ics=100% Icu), electronic release LCD display with current metering triping alarm history and logistic selectivity etc. with spreader links on both sides complete all as directed by Engineer-in-Charge.
87Supply and fix in replacement of aluminium lugs suitable for of different size of cables as following(a) 25 sqmm to 50 sqmm
88(b)70 sqmm to 95 sqmm
89(c) 120 sqmm to 185 sqmm
90(d) 240 sqmm to 400 sqmm
91M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI earth lead wire of size 4 mm dia by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete.Note:- NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 metre shall be measured and paid for separately.
92M&L for of wall mounted 6 Way bus bar chamber connsisting with bus bar 3 phase and neutral 4 Nos 250 Amp fixed on insulators including fixing in wall or as specififed by engineer in charge Make Havells cat part No IHBC020006 or equivalent in Legrand/ L&T / BCH as approved by GE.
93Supply and fixed in repair IP 43 - Metal door Vertical TPN DB with MCCB incomer of capacity 125A incomer, IK-09 model double door built with CRCA sheet steel powder coated enclosure, Provided with insulated vertical phase bus bars/ neutral bars with shrouds/ earth bars, sticking saddles/ cement spill protector/ color coded interconnecting wire set, cable ties, blanking plates With provision for 4 Pole MCCB* as incomer and TP MCBs as outgoings complete fixed into wall with grouting work breaking of wall / cutting of wall surfaces and making goods with plaster/ wooden works colour washing to distubed surface complete Make- L&T cat part no. DEVTL006DD/ Havells/ Standrad (Note:- MCCB, MCBs are measured and paid separately)
94S&F in relacement MCB 6 to 32 Amps SP ,240 V ,10 KA 'C' curve,IP 20 complete all as specified and directed.
95S&F replacement including unservicable MCB 40 to 100 Amps TPN 10 KA,415 V 'C' Series.
96Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
97Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
98M&L for street light junction box made out of 2 mm thick MS sheet of size 250x200x150 mm incl 04 nos aluminium busbar of size 20x3 mm thick mounted on porcelain insulators and one MCB SP 6 amps etc having provn of cable glands for incoming and outgoing cables, fixed to pole with proper fixing arrangement complete all as specified and directed.
99Supply & Fixing in replacement LED street light 72W LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge
100Supply only in repair of 2*2.5 Sqmm flexile unarmoured copper cable pvc sheathed for street light to PVC junction box connection in Pvc conduit as directed.
101M&L for PCC (1:3:6) type C2 with 40 mm stone aggregate for base / foundation / earthing chamber / chamber cover including form work complete all as directed by EIC
102M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete.
103Supply and fix in replacement of changover switch 400 Amp , 415 volts, 4 pole of onload with sheet steel enclouser suitable for existing panel complete all as specified and directed.L&T Cat part No-CO44000OOOO or equivalent legrand/Havells
104Supply and fix in replacement of changover switch 630 Amp , 415 volts, 4 pole of onload with sheet steel enclouser suitable for existing panel complete all as specified and directed.L&T Cat part No-CO43600OOOO or equivalent legrand/Havells
105Supply and Fix in repair ON Load change over switch 415 V in sheet metal enclosure 4 pole of capacity 200 Amps as directed
106S&F SS enclosure for MCCB suitable for upto 250A 4 pole for MCCB to be fixed with all fixing accessories complete all as specifed and directed. (Make - L&T CAT PART NO CM91003OOOD or equivalent as per Appx B as approved by GE.)
107S&F in repair LT Feeder Pillar ( Kiosk )of suitable made out 3.15 mm thick CRCA Sheet duly powder coated rust proof paint out door type double door with openable Front door including locking arrangement with Copper Busbar 400 amps rating with MCCB 250 Amps 4pole 16KA thermal megnatic adustable type for incoming and fixed on angle iron frame and PCC plinth complete as directed.
108SITC in repair of cubical type indoor LT panel with ribbed type external surface, made of high quality CRCA 2.0 MM thick duly powder coated dust proof paint MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc. and lifting 4 hook should be provided at top of panel and panel should be comparising of following:-(New bldg near stairs)1) Incoming:-(a) Bus bars of alluminium strips of 300 Amp current rating capacity 3 phase and neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 200 Amps 4 pole 36KA, 415 V thermal megnatic release type - 01 (c) multifunction meter with LCD display accuracy class 0.5 to measure voltage,current ,power with suitable size CT(d) LED indicating lamp set of 03 R,Y,B2) OUT GOING(a) MCCB 100 Amps 4 pole 25 KA 415 Volts thermal megnatic release type -02(b) MCCB 63 Amps 4 pole 10 KA 415 Volts thermal megnatic release type -01Note:- internal wiring for indicating lamp and multifunction meter should be with 1.5 sqmm FRLSH copper wire all outgoing feeder shall be connected with suitable size of bus baar and marrking of incomer and outgoing feeder with synthetic enamel paint .
109SITC in repair of cubical type outdoor type LT panel with ribbed type external surface, made of high quality CRCA sheet double door duly powder coated rust proof paint 3.15MM thick MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc.and lifting 4 hook should be provided at top of panel and panel should be comparising of following:- (family ward back side)1) Incoming:-(a) Bus bars of AL strips of 400 Amp current rating capacity, length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 160 Amps 4 pole 25 KA, 415 V thermal megnatic release type - 01 No. for incoming.(c) multifunction meter with LCD display accuracy class 0.5 to measure voltage,current ,power with suitable size CT(d) LED indicating lamp set of 03 R,Y,B2) OUT GOING(a) MCCB 125 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 01 Nos. for outgoing.(b) MCCB 63 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 01 Nos. for outgoing.note:-internal wiring for indicating lamp and multifunction meter should be with 1.5 sqmm FRLSH copper wire, all outgoing feeder shall be connected with suitable size of bus baar and marrking of incomer and outgoing feeder with synthetic enamel paint .
110SITC in repair of cubical type outdoor type LT panel with ribbed type external surface, made of high quality CRCA sheet double door duly powder coated rust proof paint 3.15MM thick MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc.and lifting 4 hook should be provided at top of panel and panel should be comparising of following:- (Near medical ward 2)1) Incoming:-(a) Bus bars of AL strips of 400 Amp current rating capacity, length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 250 Amps 4 pole 25 KA, 415 V thermal megnatic release type - 01 No. for incoming.(c) multifunction meter with LCD display accuracy class 0.5 to measure voltage,current ,power with suitable size CT(d) LED indicating lamp set of 03 R,Y,B2) OUT GOING(a) MCCB 125 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 04 Nos. for outgoing.(b) MCCB 100 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 01 Nos. for outgoing.(c ) MCB SPN 40 A-02 for outgoing note:-internal wiring for indicating lamp and multifunction meter should be with 1.5 sqmm FRLSH copper wire, all outgoing feeder shall be connected with suitable size of bus baar and marrking of incomer and outgoing feeder with synthetic enamel paint .
111SITC in repair of cubical type outdoor type LT panel with ribbed type external surface, made of high quality CRCA sheet double door duly powder coated rust proof paint 3.15MM thick MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc.and lifting 4 hook should be provided at top of panel and panel should be comparising of following:- (Near physio main road)1) Incoming:-(a) Bus bars of AL strips of 400 Amp current rating capacity, length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 250 Amps 4 pole 25 KA, 415 V thermal megnatic release type - 01 No. for incoming.(c) multifunction meter with LCD display accuracy class 0.5 to measure voltage,current ,power with suitable size CT(d) LED indicating lamp set of 03 R,Y,B2) OUT GOING(a) MCCB 125 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 04 Nos. for outgoing.(b) MCCB 100 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 01 Nos. for outgoing.(c ) MCB SPN 40 A-02 for outgoingnote:-internal wiring for indicating lamp and multifunction meter should be with 1.5 sqmm FRLSH copper wire, all outgoing feeder shall be connected with suitable size of bus baar and marrking of incomer and outgoing feeder with synthetic enamel paint .
112SITC in repair of cubical type outdoor type LT panel with ribbed type external surface, made of high quality CRCA sheet double door duly powder coated rust proof paint 3.15MM thick MS Flat iron clamp/angle iron of size 40X40X6 mm with nut, bolt washer etc shall be provided if required at site comp;lete including necessary PCC foundation with PCC(1:3:6)/bricks works and necessary earth work etc.and lifting 4 hook should be provided at top of panel and panel should be comparising of following:- (MH Back side)1) Incoming:-(a) Bus bars of AL strips of 400 Amp current rating capacity, length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 250 Amps 4 pole 25 KA, 415 V thermal megnatic release type - 01 No. for incoming.(c) multifunction meter with LCD display accuracy class 0.5 to measure voltage,current ,power with suitable size CT(d) LED indicating lamp set of 03 R,Y,B2) OUT GOING(a) MCCB 125 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 02 Nos. for outgoing.(b) MCCB 63 Amps 4 pole 16 KA, 415 V thermal megnatic release type - 02 Nos. for outgoing.note:-internal wiring for indicating lamp and multifunction meter should be with 1.5 sqmm FRLSH copper wire, all outgoing feeder shall be connected with suitable size of bus baar and marrking of incomer and outgoing feeder with synthetic enamel paint .
113M & L for maint/servicing of AMF panel of any make model and repair of unsv wiring of size (A-Z,0-9) including cleaning resetting / adjustment of relays, calibration of timing, relays, conract checking and replacing following parts etc as specified and as required of existing make for for 250 KVA DG set complete all as specified and directed.Note : Parts shall be measured and paid seperately as supply only
114Supply and fix in replacement Advanced AMF controlled unit GCU for (Genset controller unit) for RPM, LLOP / LO battery, low water, low fuel, HTC, V belt safety etc for AMF panel of 250 KVA DG set of existing make.
115Supply and fix in repair 4 pole Power contactor MCX 43, 415 V ,400 Amp alongwith complete new wiring in existing panel complete all as specified and directed by Engr-in-charge.
116Supply and fix in repair 3 pole contactor MCX 32, suitable for 415 volt, 160 Amp alongwith complete new wiring in existing panel complete all as specified and directed by Engr-in-charge.
117Supply and fixin repair 3 pole contactor MCX 34, suitable for 415 volt , 255 Amp alongwith complete new wiring in existing panel complete all as specified and directed by Engr-in-charge.
118Supply and fix in repair 3 pole contactor MCX 12, suitable for 415 volt, 63 Amp alongwith complete new wiring in existing panel complete all as specified and directed by Engr-in-charge.
119Supply,fixing in Replacement of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light .The sensor (nature switch ) along with suitable power contactor,MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FR grade SMC junction box confirming to IP 54 suitable for three phase phase of 12KW model -Swadeep -02EC12kW3P of make -Nature switch or equivalent in legrand/siemens.
120S&F in replacement name board of transformer and DG Sets on ACP Sheet having size of 2 feet x 3 feet indicating Capacity , Date of installation, SM/MES No, Make complete all as specified and directed by Eng-in-Charge.,
121M&L for Painting of transformer 200 KVA applying two coats of synthetic enamel paint of grey colour by spraying complete including preparation of old surfaces, removing & cleaning of oil/grease all as specified and directed by Engineer in Charge.
122M&L for Painting of transformer 315 KVA applying two coats of synthetic enamel paint of grey colour by spraying complete including preparation of old surfaces, removing & cleaning of oil/grease all as specified and directed by Engineer in Charge.
123M&L for Painting of transformer 400 KVA applying two coats of synthetic enamel paint of grey colour by spraying complete including preparation of old surfaces, removing & cleaning of oil/grease all as specified and directed by Engineer in Charge.
124Schedule of Credit Total in Figures 0.0 0.0 -50114.0 Quoted Rate in Figures Select 0.0 0.0 Zero Only 0.0 Quoted Rate in Words INR Minus Fifty Thousand One Hundred & Fourteen Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58469349
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42 Lakhs
LAST DATE 03-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Lt/Ht Cable Network, Transformers, Lt Switch Gears/Acbs, Ht Switch Gears/Vcbs And Connected Items At Zone-Ii Under Age E/M Of Ge Jaipur
Basic Detail
Tender No 82603/JPR/E8
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 10 Nov 2026
Submission Date 03 Dec 2026
Open Date 05 Dec 2026
Finance
Tender Value 42 Lakhs
Tender Fee 500
EMD 84000
Exemption Not Available
Document List
092b160e-8f6a-4a27-a852-244f16eff2a5.html
BOQ_894919.xls
MAKE603.pdf
TENDER82603.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Dec 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

092b160e-8f6a-4a27-a852-244f16eff2a5.html

xls

BOQ_894919.xls

pdf

MAKE603.pdf

pdf

TENDER82603.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender