Tender For Provn Of External Services To Md Accn Project (Map) At Mumbai Phase-Ii Under Ge (W) Colaba
Tender Value
7.30 Crore
Estimated cost
Bid Submission
01 Dec 2026
9 days left
EMD
6.90 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of External Services To Md Accn Project (Map) At Mumbai Phase-Ii Under Ge (W) Colaba
BOQ
| Sl. No. | Item Description |
| 1 | SCH 'A' PART-I To VIINote: This schedule is pre-priced by MES and the rate indicated under Col 5 signifies this fact only |
| 2 | Total amount of Sch 'A' Part-I (Building and Structures) |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch 'A' Part-III (Internal Electric Supply) |
| 5 | Total amount of Sch 'A' Part-IV (Sewage Disposal) |
| 6 | Total amount of Sch 'A' Part-V (External Water Supply) |
| 7 | Total amount of Sch 'A' Part-VI (External Electric Supply) |
| 8 | SCHEDULE 'A' PART-VII (MISCELLANEOUS B/R AND E/M WORKS)Schedule 'A\\" Part-II to VI items, which are not Prepriced by MES are given here under, Bidders shall insert their rate in Column -7 only and the Estimated rate indicates as \\"Rs 0.00\\" under Col 5 are for that purpose only. |
| 9 | Supply, installation commissioning and testing of oil cooled, copper wound, step down BIS marked & BEE star labelled - II transformer of capacity not less than 1000 KVA plinth mounted Outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase , LT 433 volt 3 phase 4 wire , 50 c/s oil immersed naturally cooled externally cooling tube core type. delta connection on primary HT 11 KV side and star connection on secondary LT 433 volt with tapping at +/- 2.5%, +/-5% & +/- 7.5 % on HV side. The transformer shall confirm with the requirement as per IS-1180 part I 2014 and oil shall confirm to IS-335, 1983. The temp rise and oil temprature shall as per IS-1180 part I 2014 when measured by the resistance method after continous full load run and on ambient temp of 48 degree centrigrade copper wound, ( losses shall be as per IS-1180 part I 2014 EEL-2 with amendment no-4. formerly EEL-3 (till 30-03-2022). (For Colaba site-1 88DUs Major Qtrs)a) HV bushing and cable box of suitable size. b) LV bushing and cable box of suitable size. c) oil conservator. d) Dehydrating breather with first fill of dehydrating agent. e) Thermometer pocket with thermometer dial of suitable size. f) Two earthing terminals on tank and tank cover with lugs to suit 32x6mm strip. g) Rating plate. h) Terminal marking plate.j) Oil level indicator gauge. |
| 10 | k) drain out valve (oil tank), exhaust vent, air release valve, temp gauge, cast iron wheel pocket etc complete all as specified and directed and filter valve, Lifting lugs.l) Four plain rollers. (m) Oil filter plug with connection complete. (n) Extra bushing for neutral outside the cable box for providing independent earthing. o) Oil filling hole with cap. p) cable box on LV side with bushing suitable for connection on R-Y-B-N reqd with copper sandwich bus duct as directed and to be charged by means of hand operated off load(q) Buckhaulz relay(r) Temparature guage .(s) Tap changing gear including first filling of new transformer oil of dielectric strength not less than 55KV with all fitting and accessories such as LT box , HT box with necessary items.(t) Explosion Vent (u) Air Vent /pressure relief device suitable for outdoor transformer (v) Diagram and rating plate (w) Marshal Box (x) Siliica gel (y) Breather assy for outdoor construction of capacity not less than 1000 KVA Transformer complete all as specified and as directed. |
| 11 | Supply, installation commissioning and testing of oil cooled, copper wound, step down BIS marked & BEE star labelled - II transformer of not less than capacity 400 KVA plinth mounted Outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase , LT 433 volt 3 phase 4 wire , 50 c/s oil immersed naturally cooled externally cooling tube core type. delta connection on primary HT 11 kv side and star connection on secondary LT 433 volt with tapping at +/- 2.5%, +/-5% & +/- 7.5 % on HV side .The temp rise and oil temprature shall as per IS-1180 part I 2014 when measured by the resistance method after continous full load run and on ambient temp of 48 degree centrigrade copper wound, ( losses shall be as per IS-1180 part I 2014 EEL-2 with amendment no-4. formerly EEL-3 (till 30-03-2022). (for Colaba site-2 & 3 for 58 & 59 DUs ORs Qtrs)a) HV bushing and cable box of suitable size. b) LV bushing and cable box of suitable size. c) oil conservator. d) Dehydrating breather with first fill of dehydrating agent. e) Thermometer pocket with thermometer dial of suitable size. f) Two earthing terminals on tank and tank cover with lugs to suit 32x6mm strip. g) Rating plate. h) Terminal marking plate. j) Oil level indicator gauge.k) drain out valve (oil tank), exhaust vent, air release valve, temp gauge, cast iron wheel pocket etc complete all as specified and directed and filter valve, Lifting lugs. l) Four plain rollers. |
| 12 | (m) Oil filter plug with connection complete. (n) Extra bushing for neutral outside the cable box for providing independent earthing. o) Oil filling hole with cap. p) cable box on LV side with bushing suitable for connection on R-Y-B-N reqd with copper sandwich bus duct as directed and to be charged by means of hand operated off load (q) Buckhaulz relay (r) Temparature guage (s) Tap changing gear including first filling of new transformer oil of dielectric strength not less than 55KV with all fitting and accessories such as LT box , HT box with necessary items.(t) Explosion Vent (u) Air Vent /pressure relief device suitable for outdoor transformer (v) Diagram and rating plate (w) Marshal Box (x) Siliica gel (y)Breather assy for outdoor construction of capacity not less than 400 KVA Transformer as specified and directed. |
| 13 | M&L for Construction of RCC plinth/foundation for upto 1000 KVA outdoor oil-filled transformer, including excavation, PCC bed, RCC foundation/plinth of required size and height, reinforcement steel, shuttering/formwork, anchor bolts/embedded plates as required, finishing, curing, backfilling and compaction, complete in all respects as per approved structural drawings and transformer manufacturer’s recommendations and drawings complete all as specified and directed. |
| 14 | M&L for Providing and installing fencing at the distance of 2.5 meter from all around upto 1000 kVA outdoor transformer , comprising of GI/MS angle posts of suitable size, fixed in PCC/RCC foundation at suitable spacing, with GI chain-link mesh of suitable height and gauge, including GI/MS top and bottom support members, clamps, bolts, nuts, welding, painting/galvanizing, complete with suitable-size lockable access gate made of MS/GI frame with matching chain-link mesh, hinges, locking arrangement and all necessary accessories, including excavation, concrete foundations, installation and finishing, complete in all respects as per approved drawings, specifications and electrical safety requirements complete all as specified and directed. |
| 15 | Supply, spreading and compacting of clean, hard, durable gravel/stone aggregate of approved quality and size (typically 40 mm), around and below outdoor 11 kV grade transformer upto 1000 KVA installation upto 100 mm depth, including preparation of ground, leveling, dressing, filling, and all necessary labour, tools, equipment and transportation, complete all as specified and directed. |
| 16 | Supply , install, testing and comissioning of Vaccum Circuit Breaker of 400 Amps, 250 MVA rupturing capacity at 11 KV rated , fault level of 18.3 KA for 3 sec totally enclosed, air insulated metal clad housing, bus bar both side extendable type, floor mounting, horizontal isolation, vermin proof , conforming to IP-4X, fully interlocked horizontal drawout type operation sequence 0.03 sec-CO-3 min. CO having double isolation including battery charger panel for HT panel of 24 volts 60 AH at 10 hrs discharge rate self containted floor mounted sheet steel cabinate with 2 tiers for housing the batteries. The charging equipment will be operated from 450v 3 phase 50 c/s supply with 12v 65AH SMF batteries complete supply, install, test and commissioning for HT switch gears complete all as directed ( For Coloba site-2 & 3 at new sub station with having provision for one incoming and one out going in the same VCB with PT are as under :-(i) Manually and motor operated, spring charged (release closing mechanism) trip free type , triple pole truck mounted draw out, vaccum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication \\"OFF\\" push buttons for emergency trip test/ service position limit switches with min 6 NC breaker auxillary contact in service position, 30/24 volts DC shut trip coil and strip heaters with thermo start switch. One heater in CT chamber and one heater at VCB chamber to prevent moist 400 Amp air insulated but encapsulated copper bus bar tinned coated having provision for extendable both side. (ii) C.T Chamber with double wound C.T 's 50//5A/5A, (seprate core for metering-03 and seprate core for protection-03) 15VA burden, class 5P 10 for protection and class 0.5 for instrumentation - 03 Nos. |
| 17 | (iii) Voltage Transformer with 3 Nos 1 phase, 3 limbs connected in star, class 0.5 accuracy, 11 KV/3/110V/3, 100 VA burden, with primary and secondry fuses and isolating plugs. (iv) Following protection shall be provided :- (a) Microprocessor based 3 Nos outer element for over current and one middle earth - fault with IDMT shelf power relay with shunt trip on 30/24 volts, DC, consisting 3 element over current relay with setting from 50 to 200 % and earth fault with setting from 10 to 80 %.(b) Anti pumping relay and master trip relay. (v) All wiring necessary for the above including inter-connection. The size of the conductor should not be less than 1.5 sq mm copper wire where required. (vii) Test terminal box fuses/2A SP MCB, circuit labels, set of phases, indication lamps etc, as per standard practice as under.(a) Red breaker close (ON).(b) Green breaker open (OFF)(c) Amber-Auto trip(d) Clear-trip circuit healthy(viii)The following meters are to be provided:-(a)Digital type frequency meter range 45 to 55 Hz(b)Digital voltmeter range 0-15 KV and suitable for 110 AC square dial with shrouded terminal & protection fuses. |
| 18 | (c)Digital Ammeter 0-400A rating.(d)Clear-trip circuit healthy(e)White -3 Nos one paper phase.(f)Blue spring charged(g)Power factor meter-Range-0.5 lag to 0.5 lead.(ix)6 Nos window annunciation panel with audio & visual indicator(a)Over Current & earth fault-2 windows(b)Spares-04 windows(x)Power pack unit 220V AC to 24 Volt DC complete with battery back up (maintenance free) for operation of relays including charging equipment 01 set(xi)Control :- T-N-C (Trip, Neutral, Close) Breaker control switch with indication arrangement(xii)Terminal box with single gland trifurcating cable box suitable for 11 KV aluminium XLPE(UE) cable of size 3x150 Sqmm for incoming of breaker on back side of HT panel and having provision for one side terminal box for connecting outgoing cable of size 3 core 150 sq mm to transformer.(xiii)HT Danger Plate (As per specification)(xiv)2 Runs of not less than 30x6mm earth bus bar shall be provided for full length of the panel.(xv)Integrate earth switch as required. |
| 19 | Supply, install, testing and commissioning Vacuum Circuit Breaker of 400 Amps, 250 MVA rupturing capacity at 11 KV rated, fault level of 18.3 KA for 3 sec. totally enclosed, air insulated metal clad housing, bus bar both side extendable type, floor mounting, horizontal isolation, vermin proof, conforming to IP-4X, fully interlocked horizontal drawout type operation sequence 0-0.3 sec-CO-3 min-CO having double isolation including battery charger panel for HT panel of 24 volts 60 AH at 10 hrs discharge rate self containted floor mounted sheet steel cabinate with 2 tiers for housing the batteries. The charging equipment will be operated from 450v 3 phase 50 c/s supply with 12v 65AH SMF batteries complete supply, install, test and commissioning for HT switch gears complete all as directed (For colaba site No.1 88 DU's Major Qtrs) as Incomers with PT ):-(i) Manually and motor operated, spring charged (release closing mechanism) trip free type, triple pole truck mounted draw out vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charged/discharge mechanical indication “OFF” push buttons for emergency trip (shrouded) test/service position limit switches with min 6 NO/6 NC breaker auxiliary contact in service position, 30/24 volts DC shunt trip coil and strip heaters with thermostat switch. One heater in CT chamber and one heater at VCB chamber to prevent moisture absorption.(ii) 400 Amp air insulated but encapsulated copper bus bar tinned coated having provision for extendable both side. |
| 20 | (iii) C.T Chamber with double wound C.Ts 100/5A/5A (separate core for metering -03 Nos and separate core for protection-03 Nos) 15 VA burden, Class 5P 10 for protection and class 0.5 for instrumentation – 03 Nos.(iv) Voltage Transformer with 3 numbers 1 phase, 3 limbs connected in star, class 0.5 accuracy, 11 KV/3/110V/3, 100 VA burden, with primary & secondary fuses and isolating plugs.(v) Following protection shall be provided:-(a) Microprocessor based 3 Nos outer elements for over current and one middle earth - fault with IDMT self power relay with shunt trip on 30/24 Volts, DC consisting 3 element overcurrent relay with setting from 50 to 200% and earth fault with setting from 10 to 80%. (b) Anti pumping relay and Master trip relay wiring necessary for the above including inter-connections. The size of the conductor should not be less than 1.5 sq mm copper wire where required.(vii) Test terminal box fuses/2A SP MCB, circuit labels, set of phases, indication lamps etc, as per standard practice as under.(a) Red breaker close (ON).(b) Green breaker open (OFF)(c) Amber-Auto trip(d) Clear-trip circuit healthy |
| 21 | (viii) The following meters are to be provided:-(a) Digital type frequency meter range 45 to 55 Hz.(b) Digital voltmeter range 0-15 KV and suitable for 110 AC square dial with shrouded terminal & protection fuses.(c) Digital Ammeter 0-400A rating.(d) Clear-trip circuit healthy(e) White - 3 Nos one paper phase.(f) Blue spring charged(g) Power factor meter-Range-0.5 lag to 0.5 lead.(ix) 6 Nos window annunciation panel with audio & visual indicator(a) Over Current & earth fault - 2 windows(b) Spares - 04 windows(x) Power pack unit 220V AC to 24 Volt DC complete with battery back up (maintenance free) for operation of relays including charging equipment 01 set(xi) Control :- T-N-C (Trip, Neutral, Close) Breaker control switch with indication arrangement) |
| 22 | (xii) Terminal box with single gland trifurcating cable box suitable for 11 KV aluminium XLPE (UE) cable of size 3x150 Sqmm for incoming cable on back side of panel and having provision from one side for exteson of bus bar of 400 Amps tinned copper to connect other VCB with common bus bar.(xiii) HT Danger Plate (As per specification)(xiv) 2 Runs of not less than 30x6mm earth bus bar shall be provided for full length of the panel.(xv) Integrate earth switch as required. |
| 23 | Supply , install, testing and comissioning of Vaccum Circuit Breaker of 400 Amps, 250 MVA rupturing capacity at 11 KV rated , fault level of 18.3 KA for 3 sec totally enclosed, air insulated metal clad housing, bus bar both side extendable type, floor mounting, horizontal isolation, vermin proof , conforming to IP-4X, fully interlocked horizontal drawout type operation sequence 0.03 sec-CO-3 min. CO having double isolation including battery charger panel for HT panel of 24 volts 60 AH at 10 hrs discharge rate self containted floor mounted sheet steel cabinate with 2 tiers for housing the batteries. The charging equipment will be operated from 450v 3 phase 50 c/s supply with 12v 65AH SMF batteries complete supply, install, test and commissioning for HT switch gears complete all as directed ( 02 Nos for proposed Sub Station at Coloba site No -1, 88 DU's Major Qtrs) as outgoing feeder with CTs Chamber with double wound Size 100/5A/5A and 02 Nos Adapter type VCB panel for retrofit solution for taking supply from existing Sub station No- 4 & 8 with CTs Chamber with double wound 50/5A/5A by means of interconnection with existing VCB are as under :-(i) Manually and motor operated, spring charged (release closing mechanism) trip free type , triple pole truck mounted draw out, vaccum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication. Spring charge/discharge mechanical indication \\"OFF\\" push buttons for emergency trip test/ service position limit switches with min 6 NC breaker auxillary contact in service position, 30/24 volts DC shut trip coil and strip heaters with thermo start switch. One heater in CT chamber and one heater at VCB chamber to prevent moist 400 Amp air insulated but encapsulated copper bus bar tinned coated having provision for extendable both side. |
| 24 | (ii) CTs will be (seprate core for metering-03 Nos and seprate core for protection-03 Nos, 15VA burden, class 5P 10 for protection and class 0.5 for instrumentation - 03 Nos. (iii) Voltage Transformer with 3 Nos 1 phase, 3 limbs connected in star, class 0.5 accuracy, 11 KV/3/110V/3, 100 VA burden, with primary and secondry fuses and isolating plugs.(iv) Following protection shall be provided :- (a) Microprocessor based 3 Nos outer element for over current and one middle earth - fault with IDMT shelf power relay with shunt trip on 30/24 volts, DC, consisting 3 element over current relay with setting from 50 to 200 % and earth fault with setting from 10 to 80 %. (b) Anti pumping relay and master trip relay.(v) All wiring necessary for the above including inter-connection. The size of the conductor should not be less than 1.5 sq mm copper wire where required.(vii) Test terminal box fuses/2A SP MCB, circuit labels, set of phases, indication lamps etc, as per standard practice as under.(a) Red breaker close (ON).(b) Green breaker open (OFF)(c) Amber-Auto trip(d) Clear-trip circuit healthy(viii)The following meters are to be provided:-(a)Digital type frequency meter range 45 to 55 Hz(b)Digital voltmeter range 0-15 KV and suitable for 110 AC square dial with shrouded terminal & protection fuses. |
| 25 | (c) Digital Ammeter 0-400A rating.(d) Clear-trip circuit healthy(e) White -3 Nos one paper phase.(f) Blue spring charged(g) Power factor meter-Range-0.5 lag to 0.5 lead.(ix) 6 Nos window annunciation panel with audio & visual indicator(a) Over Current & earth fault-2 windows(b) Spares-04 windows(x) Power pack unit 220V AC to 24 Volt DC complete with battery back up (maintenance free) for operation of relays including charging equipment 01 set(xi) Control :- T-N-C (Trip, Neutral, Close) Breaker control switch with indication arrangement(xii)Terminal box with single gland trifurcating cable box suitable for 11 KV aluminium XLPE(UE) cable of size 3x150 Sqmm for incoming of breaker on back side of HT panel and having provision for one side terminal box for connecting outgoing cable of size 3 core 150 sq mm to transformer.(xiii) HT Danger Plate (As per specification)(xiv) 2 Runs of not less than 30x6mm earth bus bar shall be provided for full length of the panel.(xv) Integrate earth switch as required. |
| 26 | Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with solid/stranded copper conductor, 1100 volts grade as per IS 7098 part-I earthed of size 6 Sqmm x 4 core complete all as specified and directed. |
| 27 | All as per Item No. 17 above but 6 Sqmm x 3 core |
| 28 | All as per Item No. 17 above but 2.5 Sqmm x 3 core |
| 29 | Supply and fix cable double compression copper stainless steel gland for fixing armoured cable in panel of size 400Sqmm x 3.5 core complete all as specified and directed. |
| 30 | All as per Item No. 20 above but 300 Sqmm x 3.5 core |
| 31 | All as per Item No. 20 above but 240 Sqmm x 3.5 core |
| 32 | All as per Item No. 20 above but 150 Sqmm x 3.5 core |
| 33 | All as per Item No. 20 above but 70 Sqmm x 3.5 core |
| 34 | All as per Item No. 20 above but 50 Sqmm x 3.5 core |
| 35 | All as per Item No. 20 above but 35 Sqmm x 3.5 core |
| 36 | All as per Item No. 20 above but 16 Sqmm x 4 core |
| 37 | All as per Item No. 20 above but 10 Sqmm x 4 core |
| 38 | All as per Item No. 20 above but 6 Sqmm x 4/3 core |
| 39 | All as per Item No. 20 above but 2.5 Sqmm x 3 core |
| 40 | Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 120 mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings complete all as specified and directed. |
| 41 | Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 110 mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings complete all as specified and directed. |
| 42 | Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 80mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings complete all as specified and directed. |
| 43 | Supply and laying High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 50mm dia for laying of cable protection complete to walls/ trenches/floor/ceilings complete all as specified and directed. |
| 44 | M&L for road cutting of size 30 cm width x 45 cm depth for laying of cables including making good the road with necessary returning and type B1 PCC in 1:2:5 15 cm thick from top and all as directed |
| 45 | Supply & fix, install, testing and commissioning of LT Panel Board, Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet, 2mm thick, factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871-1993 (2002) dust and vermin proof, provn for ventilation, angle iron frame support and base frame 150mm height. Suitable size to accommodate the items mentioned below and having seperate compartment / chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:- (Location : Colaba site-01 88 DUs Major qtrs ) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 1600 Amps /Ph and 800Amps/Neutral(b) ACB, 4Pole, MDO, 60KA 1600 Amp with micro processed based releases ( incoming ) -01 Nos(c) ACB, 4Pole, MDO, 60KA 1250 Amp with micro processed based releases ( outgoing ) -01 No for building load.(d) MCCB 600 Amp, 50 Hz 415 volts 4 pole repuritring capacity 50 KA, (out going) - 01 Nos for APFC panel(e) MCCB TP 400 Amp, 50 Hz 415 volts 4 pole repuritring capacity 50 KA -01 Nos ( AMF Panel ) |
| 46 | (f) MCB 10 Amp, 50 Hz 415 volts 4 pole repuritring capacity 10KA - 01 No ( Street light )(g) KWH meter LCD CI 0.5 accuracy, with RS 485 working on 415 volts, CT operated secondary site selectable 1A/5A, flush mounting 96x96mm size auto scaling of kilo, mega and giga, parameter site selectable KWH /KVA /PF/V/W complete - 2 Nos for Main incomer & street light only.(h) Voltmeter digital type (0-500V) -01 No(i) Ammeter digital type -04 No(j) CTs 1600/5Amps - 03 Nos, CTs 1250/5Amps - 3 Nos, CTs 600/5Amps - 3 Nos, CTs 400/5Amps - 3 Nos(k) Indicating lamp LED type (R,Y,B) - 04 Set(l) Control panel wiring with 1.5sqmm PVC insulator & multistrand single core copper conductor cable for voltmeter, ammeter, Selector switch and indicator lamp complete. |
| 47 | Supply & fix, install, testing and commissioning of LT Panel Board, Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet, 2mm thick, factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871-1993 (2002) dust and vermin proof, provn for ventilation, angle iron frame support and base frame 150mm height. Suitable size to accomodate the items mentioned below and having seperate compartment / chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:- (Location : Site No. 2&3 (Sub Station near 58 DUs for ORs and 59 DUs for ORs) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 800 Amps /Ph and 400 Amps/Neutral(b) ACB, 4Pole, MDO, 50KA, 800 Amp with micro processed based releases ( incoming ) -01 Nos(c) MCCB 315 Amp, 50 Hz, 415 volts 4 pole repuritring capacity 35 KA, (out going) -02 Nos ( DG AMF )(d) MCCB TP 200 Amp, 50 Hz, 415 volts 4 pole repuritring capacity 35 KA -01Nos ( APFC Panel) |
| 48 | (e) MCCB 63 Amp, 50 Hz 415 volts 4 pole repuritring capacity 25KA -01 No ( Street light )(f) KWH meter LCD CI 0.5 accuracy, with RS 485 working on 415 volts, CT operated secondary site selectable 1A/5A, flush mounting 96x96mm size auto scaling of kilo, mega and giga, parameter site selectable KWH/KVA/PF/W complete - 2 Nos for Main incomer & street light only(g) Voltmeter digital type (0-500V) -01 No(h) Ammeter digital type -05 Nos(i) CTs 800/5Amps - 03 Nos, CTs 315/5Amps - 6 Nos, CTs 200/5 Amps - 3 Nos, CTs 63 /5 Amps - 3 Nos(k) Indicating lamp LED type (R,Y,B) - 01 Set(l) Control panel wiring with 1.5sqmm PVC insulator & multistrand single core copper conductor cable for voltmeter, ammeter, Selector switch and indicator lamp complete. |
| 49 | Supply & fix, install, testing and commissioning of Wall mounted LT Panel Board (building utility panel Each), Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet, 2mm thick, factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871 1993(2002) dust and vermin proof, provn for ventilation, angle iron frame support and base frame 150mm height. Suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar,switch gear etc all as specified and comprising of following ( Location : Site No.01 (88 Dus Major qtrs ) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 200 Amps /Ph and 200Amps/Nuetral(b) MCCB 160 Amp 50 Hz 415 volts repuritring capacity 36KA (incoming) - 01 No(c) MCB TPN 125 Amp 50 Hz 415 volts repuritring capacity 25 KA -01 nos(d) MCB TPN 20 Amp 50 Hz 415 volts repuritring capacity 10 KA -01Nos(e) MCB TPN 16 Amp 50 Hz 415 volts repuritring capacity 10 KA -01 No |
| 50 | (f) MCB SPN 10 Amp 50 Hz 240 volts repuritring capacity 10 KA -01 Nos(g) MCB DP 6 Amps, 10 KA - 2 Nos(h) Contactor 3 pole, 6 Amps , 415 volts - 1 Nos for street light with timer complete .(i) Voltmeter digital type (0-500V) -01 No(j) Ammeter digital type -01 No(k) CTs 160/5 Amps -03 Nos(l) Indicating lamp LED type (R,Y,B)(m) Control panel wiring with 1.5sqmm PVC insulator & multistrand single core copper conductor cable for voltmeter, ammeter, Selector switch and indicator lamp complete. |
| 51 | Supply & fix, install, testing and commissioning of wall mounted LT Panel Board (building utility panel Each), Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet, 2mm thick, factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871-1993(2002) dust and vermin proof , provn for ventilation , angle iron frame support and base frame 150mm height. Suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar,switch gear etc all as specified and comprising of following (Sub Station-near Site No. 2 & 3 (58 DUs for ORs and 59 DUs) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 200 Amps /Ph and 200Amps/Nuetral(b) MCCB 100 Amp 50 Hz 415 volts repuritring capacity 25 KA(incoming) - 01 No.(c) MCB TPN 63 Amp 50 Hz 415 volts repuritring capacity 10 KA - 01 nos(d) MCB TPN 16 Amp 50 Hz 415 volts repuritring capacity 10 KA -01(e) MCB SPN 06 Amp 50 Hz 240 volts repuritring capacity 10 KA -01 Nos .(f) Voltmeter digital type (0-500V) -01 No(g) Ammeter digital type -01 No(h) CTs 100/5 Amps -03 Nos(i) Indicating lamp LED type (R,Y,B)(k) Control panel wiring with 1.5sqmm PVC insulator single core copper cable for voltmeter, ammeter, Selector switch and indicator lamp complete. |
| 52 | Supply & fix, install, testing and commissioning of LT Panel Board for DG with AMF , Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet , 2mm thick , factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated , 40 microns as per IS 13871 1993 (2002) dust and vermin proof , provn for ventilation , angle iron frame support and base frame 150mm hight. Suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:- (Location : Site No. 01 (Sub Station near 88 DUs) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 800 Amps /Ph and 400 Amps/Nuetral(b) MCCB 400 Amps, 50 KA, 4 Pole, 2 Nos as incommer, 1 for DG Supply and one for normal supply Type DN3-400N , ( incoming)-02 Nos(c) MCCB 250 Amps, 36 KA, 4 Pole, (out going)-01 Nos ( FF Panel )(d) MCCB 160 Amps, 36 KA, 4 Pole, (out going)-01 Nos ( UTILITY BUILDING LOAD )(e) MCCB 32 Amps, 36 KA, 4 Pole, (out going)-01 Nos |
| 53 | (f) MCB SPN 16 Amp 50 Hz 240 volts repuritring capacity 10 KA -02 Nos(g) KWH meter LCD CI 0.5 accuracy , with RS 485 working on 415 volts, CT operated secondary site selectable 1A/5 A , flush mounting 96x96 mm size auto scaling of kilo, mega and giga, parameter site selectable KWH/KVA/PF/W complete. -5 Nos(h) Voltmeter digital type (0-500V) -01 No(i) Ammeter digital type -05 Nos(k) CTs 400/5Amps - 06 Nos , CTs 250/5Amps- 3 Nos , CTs 160/5Amps - 3 Nos , CTs 32 /5 Amps - 3 Nos .(l) Indicating lamp LED type (R,Y,B) - 01 Set(m) control panel wiring for AMF panel with 1.5 sq mm multistranded, pvc insulated copper conductor cable between , relay , contactor of various capacity , voltmeter , Am meter , and their selector switch complete with CTs of ratio 400/5 Amps - 6 no , 250/5A - 3 Nos , 160/5A - 3 Nos, voltmeter flush paternion type 96 mm square dial -1 nos , Am meter digital CT operated 96 mm sqare dial flush paternion type -04 Nos , indicator lamp for 3 phase and control fuses -3 Nos complete |
| 54 | Supply & fix, install, testing and commissioning of LT Panel Board for DG with AMF , Indoor extendable type IP 52, cubical shape, three phase, 4 wire, copper bus bar, made out of CRCA sheet 2mm thick , factory fabricated, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated 40 microns as per IS 13871:1993(2002) dust and vermin proof , proven for ventilation , angle iron frame support and base frame 150mm height. Suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:- (Location : Site No. 02 & 03 (Sub Station near 58 DUs for ORs and 59 DUs for ORs) :-(a) Copper Bus Bar with PVC (Red,Yellow,Blue and Black) sleeves 800 Amps /Ph and 400 Amps/Neutral(b) MCCB 250 Amps, 36 KA, 4 Pole, 2 Nos as incomer , 1 for DG Supply and one for normal supply (c) MCCB 200 Amps, 36 KA, 4 Pole, (out going)- 01 Nos(d) MCCB 100 Amps, 36 KA, 4 pole, (out going)- 01 Nos(e) MCCB 32 Amps, 36 KA, 4 Pole, (out going)- 01 Nos |
| 55 | (f) MCB SPN 16 Amp 50 Hz 240 volts reprinting capacity 10 KA -02 Nos(g) KWH meter LCD CI 0.5 accuracy , with RS 485 working on 415 volts, CT operated secondary site selectable 1A/5 A , flush mounting 96x96 mm size auto scaling of kilo , mega and giga , parameter site selectable KWH/KVA/PF/W complete - 5 Nos(h) Voltmeter digital type (0-500V) -01 No(i) Ammeter digital type -05 Nos(k) CTs 250/5Amps - 06 Nos, CTs 200/5Amps - 3 Nos, CTs 100/5 Amps - 3 Nos, CTs 32/5 Amps - 3 Nos(l) Indicating lamp LED type (R,Y,B) -01 Set(m) control panel wiring for AMF panel with 1.5 sq mm multistranded, pvc insulated copper conductor cable between, relay , contactor of various capacity , voltmeter , Am meter, and their selector switch complete with CTs of ratio 250/5 Amps- 6 no,200/5A- 3 Nos,100/5 A- 3 Nos ,CTs 32/5 Amps - 3 Nos voltmeter flush pattern type 96 mm square dial -1 nos, Ammeter digital CT operated 96 mm square dial flush pattern type -04 Nos, indicating lamp for 3 phase and control fuses- 3 Nos complete |
| 56 | Supply, fix, in repair, commissioning & testing automatic power factor correction panel (350KVAR APFC panel) working on AC supply, 3 phase, 415 volt, 50 hz, free floormounting cubical design, factory fabricated, made out of 2 mm thick CRCA sheet, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871 1993(2002), dust and vermin proof, provision for ventilation, angle iron frame support and base frame 100mm height. Suitable size to accommodate the items mentioned below and having separate compartment / chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:-(Location - Site No. 01 (88 Dus Major qtrs sub station)(a) MCCB TPN 630 Amps, 50 KA, 415 volts AC - 1 No for incommer supply.(b) Copper bus bar of rating 600Amps per Phase and 300 Amps per Nuetral - 1 Set.(c) APFC Relay, 14 Stages Microprocessed based suitable for 415V, 3phase, AC supply - 01 No.(d) Volt meter 0/500Volt, 96X96mm with selector switch - 01 Set |
| 57 | (e) Ammeter 0/600Amp, 96X96mm with selector switch and CT's of ratio 600/5 Amps - 01 Set(f) Phase indicating lamp (Red, Yelow, Blue) - 01 Set(g) Auto / Manual Selector Switch - 01 No(h) Capacitor On/ Off Indicating lamp LED type and push buttons - 15 Sets (i) Control wiring with 1.5 / 2.5 Sqmm flexible copper conductor - 01 Job(j) Exhaust fan (Heavy duty) 230V, AC, 100mm sweep with timer control - 02 Nos(k) CT Ratio 600/5 Amp - 03 No (l) Power wiring from bus bar to MCB and MCB to Capacitor bank with suitable size of copper conductor cable of 2.5 / 4 / 6 / 10 Sqmm as required.(m) Capacitor Bank, MD XL type, 415, 50Hz, AC supply (i) 50KVAR – 02 Nos(ii) 25KVAR – 06 Nos(iii) 20KVAR – 03 Nos(iv) 15KVAR – 01 Nos(v) 10KVAR – 02 Nos(vi) 5KVAR – 01 Nos |
| 58 | (n) MCB, T.P, D curve, 415Volts, 10kA (i) 100Amps – 02Nos.(ii) 60Amps – 06Nos.(iii) 40Amps – 03No.(iv) 32Amps – 01Nos.(v) 20Amps – 02Nos.(vi) 10Amps – 01Nos.(o) Power Contactors with 2NC + 2NO, 3pole, 415Volts, 50Hz AC supply Capacitor duty MOC type (i) 25KVAR – 06Nos.(ii) 20KVAR – 03Nos.(iii) 15KVAR – 01Nos.(iv) 10KVAR – 02Nos.(v) 5KVAR – 01Nos.(vi) 50 KVAR – 02 Nos. |
| 59 | Supply, fix in repair, commissioning & testing automatic power factor correction panel (150 KVAR APFC panel) working on AC supply, 3 phase, 415 volt, 50 Hz, free floor mounting cubical design, factory fabricated, made out of 2 mm thick CRCA sheet, CPRI tested, certified and approved, powder coating with Pure Polyester Powder coated, 40 microns as per IS 13871-1993(2002), dust and vermin proof, provn for ventilation, angle iron frame support and base frame 100mm height. Suitable size to accomodate the items mentioned below and having seperate compartment / chambers for cable gallery busbar, switch gear etc all as specified and comprising of following:-(Location. Site No. 02 & 03) (Sub Station near 58 DUs for ORs and 59 DUs for ORs)(a) MCCB TPN 250 Amps, 36 KA, 415 volts AC, - 1 No for incommer supply.(b) Copper bus bar of rating 300 Amps per Phase and 200 Amps per Nuetral - 1 Set.(c) APFC Relay, 14 Stages Microprocessed based suitable for 415V, 3phase, AC supply - 01 No. |
| 60 | (d) Volt meter 0/500Volt, 96x96mm with selector switch - 01Set (e) Ammeter 0/300Amp, 96x96mm with selector switch and CT's of ratio 300/5 Amps - 01Set. (f) Phase indicating lamp (Red, Yelow, Blue) - 01Set.(g) Auto / Manual Selector Switch - 01No.(h) Capacitor On/ Off Indicating lamp LED type and push buttons - 12Sets (j) Control wiring with 1.5 / 2.5Sqmm flexible copper conductor - 01Job.(k) Exhaust fan (Heavy duty) 230V, AC, 100mm sweep with timer control - 02Nos.(l) CT Ratio 250/5A-03 Nos (m) Power wiring from bus bar to MCB and MCB to Capacitor bank with suitable size of copper conductor cable of 2.5/4/6/10Sqmm as required.(n) Capacitor Bank, MD XL type, 415,50Hz, AC supply (i) 25KVAR – 02Nos.(ii) 20KVAR – 02Nos.(iii) 15KVAR – 02Nos.(iv) 10KVAR – 02Nos.(v) 5KVAR – 02Nos. |
| 61 | (o) MCB, TP, D curve, 415Volts, 10kA (i) 60 Amps – 02 Nos(ii) 40 Amps – 02 Nos.(iii) 25Amps – 02 No.(iv) 20Amps – 02Nos(v) 10Amps – 02 Nos(p) Power Contactors with 2NC + 2NO, 3pole, 415Volts, 50Hz AC supply Capacitor duty MOC type (i) 25KVAR – 02 Nos.(ii) 20KVAR – 02 Nos.(iii) 15KVAR – 02Nos.(iv) 10KVAR – 02Nos.(v) 5KVAR – 02Nos. |
| 62 | M&L for fabrication supply and installation of MS pedestal type fire point made out of angle iron frame 50x5 mm free standing on ground / hard standing suitable for provision of hanging and including 04 nos of fire bucket 13 ltrs cap duly painted with red colour including red oxide as primer and writing letters FIRE on outer surface of fire buckets, fire stand, fire bitter, fire cutter and fire hook as per IS specification, complete all as specified and directed. |
| 63 | S& F for electric shock treatment chart of standard size for substation in english and regional language, complete all as specified and directed. |
| 64 | S& F for First aid box of adequate size and shape with complete set, complete all as specified and directed. |
| 65 | S& F for HT Cable route indicator including angle iron of size 25 mmx 25 mmx 6mm grouted into PCC 1:2:4, height upto 45 cm complete all as specified and directed. |
| 66 | S& F for LT Cable route indicator including angle iron of size 25 mmx 25 mmx 6mm grouted into PCC 1:2:4, height upto 45 cm complete all as specified and directed. |
| 67 | S& F for Fire Extinguisher CO2 type 4.5 Kg complete all as specified and directed. |
| 68 | Supplying, installing, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity of not less than 200 KVA, 3 phase, 4 wire, 415 volt, 0.8 PF, complete with control panel including integrated powder coated acoustic enclosure as per CPCB IV+ regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- |
| 69 | (A) DIESEL ENGINE :Diesel Engine for required capacity for driving not less than 200 KVA alternator multi cylinder, vertical type, 4 stroke, Radiator cooled, electric start, cold starting conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-(i) Radiator cooling(ii) Radiator fan with guard(iii) Flywheel with starter ring(iv) Air cleaner oil bath type(v) Vacuum indicator(vi) Electronic governor (vii) Exhaust silencer(viii) Fuel filter & fuel hoses(ix) Fan & water pump assembly(x) Lub oil filter & Pump(xi) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 150 AH -02 Nos DC as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch,etc - 01 Set. |
| 70 | (xii) Engine safety shut down system against low lub oil pressure and high water pressure(xiii) Exhaust gas driven turbo charger(xiv) Oil filter(xv) Lub oil cooler(xvi) Emergency stopping switch outside canopy.(xvii) Suitably designed acoustic enclosure with locking arrangement of doors as per CPCB regulations.(xviii) Suitable pollution control device to reduce air pollution.(B) ENGINE INSTRUMENT PANEL digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of Engine & Alternator :-(i) Starting switch on/off(ii) Water temp guage(iii) Hour meter cum RPM indicator(iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter(vii) Safety alarm against high water temp and lub oil pressure (viii) One Battery charger of suitable capacity seprately required for charging upto 150 AH battery in case of emergency requirement except battery charger included in DG set complete as directed |
| 71 | (C) ALTERNATOR : Shall be self excited, self regulated, brushless for 200 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ( +/- 1% ) with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364/4722 or BS-2613 of 1970 complete- 1 No.(D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof, PCC 1:2:4 type B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation including 400mm extra PCC platform around the DG set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor.(E) Bottom mounted steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. |
| 72 | (F) AMF CONTROL PANEL : Supply, fabrication, fixing,testing and commissioning , factory made, floor mounted, cubical automatic mains failure panel suitable for not less than 200 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control MCB, provn of connecting incoming & outgoing leads/bus bar as approved with and including the following accessories as under:-(i) Master switch for auto/manual/reset/off- 01 No(ii) Ammeter digital type 96x96 mm to read 0 - 500 amps with suitable size CT's 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0(iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0(iv) Digital frequency meter -01 No. aux supply 230 volts, AC(v) Push button start, stop/ reset - 01 No(vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure (vii) Battery charger, connected to load side to charge battery from mains comprising of :-(a) Transformer of adequate rating.(b) Rectifiers(c) DC Ampere and volt meter(d) Charger rate selector for trickle or high charging(e) Indicating lamp for battery charging |
| 73 | (viii) Fault accept/reset push button(ix) 02 Set of relays and contactor with MCCB 400 Amps, 4 Pole, 50 KA 415 volts for automatic start & automatically shut down of DG set.(x) By pass arrangement by providing change over switch of 400 Amps 4 Pole 02 nos in separate panel box to be installed with AMF & connecting with AMF through proper cable/bus bar of adequate ratings.(xi) control wiring from DG set/ Control Panel to AMF panel with copper cable of suitable size & cores including PVC flexible pipe. |
| 74 | Supplying, installing, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500 RPM of capacity of not less than 160 KVA, 3 phase, 4 wire, 415 volt, 50 Hz, 0.8 PF, complete with control panel including integrated powder coated acoustic enclosure as per CPCB IV+ regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- |
| 75 | (A) DIESEL ENGINE :Diesel Engine for required capacity for driving not less than 160 KVA alternator multi cylinder, vertical type, 4 stroke, Radiator cooled, electric start, cold starting conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :-(i) Radiator cooling(ii) Radiator fan with guard(iii) Flywheel with starter ring(iv) Air cleaner oil bath type(v) Vacuum indicator(vi) Electronic governor (vii) Exhaust silencer(viii) Fuel filter & fuel hoses(ix) Fan & water pump assembly(x) Lub oil filter & Pump(xi) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 150 AH -02 Nos DC as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch,etc - 01 Set. |
| 76 | (xii) Engine safety shut down system against low lub oil pressure and high water pressure(xiii) Exhaust gas driven turbo charger(xiv) Oil filter(xv) Lub oil cooler(xvi) Emergency stopping switch outside canopy.(xvii) Suitably designed acoustic enclosure with locking arrangement of doors as per CPCB regulations.(xviii) Suitable pollution control device to reduce air pollution.(B) ENGINE INSTRUMENT PANEL digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of Engine & Alternator :-(i) Starting switch on/off(ii) Water temp guage(iii) Hour meter cum RPM indicator(iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter(vii) Safety alarm against high water temp and lub oil pressure(viii) One Battery charger of suitable capacity seprately required for charging upto 150 AH battery in case of emergency requirement except battery charger included in DG set complete as directed |
| 77 | (C) ALTERNATOR : Shall be self excited, self regulated, brushless for 160 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with ( +/- 1% ) with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364/4722 or BS-2613 of 1970 complete- 1 No.(D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof. PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation including 400mm extra PCC platform around the DG set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor.(E) Bottom mounted steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. |
| 78 | (F) AMF CONTROL PANEL : Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for not less than 160 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control MCB, provn of connecting incoming & outgoing leads/bus bar as approved with and including the following accessories as under:-(i) Master switch for auto/manual/reset/off- 01 No(ii) Ammeter digital type 96x96 mm to read 0 - 500 amps with suitable size CT's 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0(iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0(iv) Digital frequency meter -01 No. aux supply 230 volts, AC(v) Push button start, stop/ reset - 01 No(vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure (vii) Battery charger, connected to load side to charge battery from mains comprising of :-(a) Transformer of adequate rating.(b) Rectifiers(c) DC Ampere and volt meter(d) Charger rate selector for trickle or high charging(e) Indicating lamp for battery charging |
| 79 | (viii) Fault accept/reset push button(ix) 02 Set of relays and contactor with MCCB 250 Amps, 4 Pole, 50 KA 415 volts for automatic start & automatically shut down of DG set.(x) By pass arrangement by providing change over switch of 250 Amps 4 Pole 02 nos in separate panel box to be installed with AMF & connecting with AMF through proper cable/bus bar of adequate ratings.(xi) control wiring from DG set/ Control Panel to AMF panel with copper cable of suitable size & cores including PVC flexible pipe. |
| 80 | Design, manufacture, supply, installation, testing and commissioning of 1600 A, 415 V, 3-Phase, 4-Wire LT Sandwich Bus Trunking System (Bus Duct) with high-conductivity electrolytic copper conductors, suitable for connecting 1000 kVA, 11 kV/415 V outdoor oil-filled transformer to indoor 1600 A LT ACB incomer panel, complete with all accessories and fittings required for a complete and operational installation.The Bus Trunking System shall be of compact sandwich construction with high-conductivity copper busbars with 100% rated neutral , low impedence construction, non hygroscopic insulation, suitably insulated and housed in a robust sheet-steel enclosure weatherproofing. The system shall be suitable for continuous operation at 1600 A, 415 V, 50 Hz, 3-Phase, 4-Wire, and shall have adequate short-circuit withstand capacity suitable for the prospective fault level at the transformer secondary.The scope shall include transformer termination/connection box and flange, LT panel termination/connection flange, flexible connectors for bus ducting with transformer and LT ACB side, expansion joints, joint packs, joint covers, end covers, supports, hangers, brackets, clamps, fasteners, earth continuity/bonding arrangement, phase identification, warning labels and all other accessories required for complete installation and complete duct fixed in Air/ wall / roof / floor with the help of MS angle iron of size 25x5 mm thick with clamps, nut bolts, anchor fastner bolts including opening of wall etc. |
| 81 | The Bus Trunking System shall be suitable for connection to the transformer LT terminals and the LT ACB panel, including any required change in direction, offsets, bends and special pieces. All joints shall be provided with suitable high-conductivity jointing arrangements and shall be tightened to the manufacturer's specified torque.The complete Bus Trunking System shall be suitable for outdoor exposure at the transformer end and shall have appropriate degree of protection, minimum IP55/IP65 as required by the installation, with suitable weatherproofing at all joints and terminations.The enclosure shall be electrically continuous and effectively earthed throughout its length with two run of copper strip of size 50x6 mm as earthing conductor and the system shall be designed to withstand the specified short-circuit thermal and dynamic stresses. The manufacturer shall submit routine/type test certificates and technical data, including current rating, temperature-rise, insulation resistance, dielectric withstand and short-circuit withstand test details.Rate shall include all materials, transportation, unloading, installation, supports, jointing, termination, testing and commissioning, complete in all respects as per approved drawings, specifications, applicable IS/IEC standards and manufacturer's recommendations complete all as directed. |
| 82 | Supply, laying, jointing field testing & commissioning complete as site as per specification of centrifugally cast (spun) Ductile iron pressure pipes of 100 mm bore (S&S) ISI marked for water conforming to IS 8329/2000 with rubber gasket jointing as per IS 5382 specification, pipe shall be outside finishing layer of Bitumen and have factory cement morter lining as per IS 8329/2000 complete with flanged end gasket, nutbolts, elbow. The rates includes all cost of material, labour required, transportation, loading, unloading & stacking etc complete all as specified and as directed. |
| 83 | Supply, laying, jointing field testing & commissioning complete as site as per specification of centrifugally cast (spun) Ductile iron pressure pipes of 150 mm bore (S&S) ISI marked for water conforming to IS 8329/2000 with rubber gasket jointing as per IS 5382 specification, pipe shall be outside finishing layer of Bitumen and have factory cement morter lining as per IS 8329/2000 complete with flanged end gasket, nutbolts, elbow. The rates includes all cost of material, labour required, transportation, loading, unloading & stacking etc complete all as specified and as directed. |
| 84 | S&F Gun metal gate valve/brass stop valve, high pressure both ends screwed down with crunch or butterfly handle with suitable size sockets on both ends nipples, unions, etc suitable for 80mm bore GI pipe complete all as specified and as directed. |
| 85 | S&F for Cast iron Air release valve with two air outlet 25 dia and fixing up on water supply main (with cap) complete with bolts, nuts, rubber insertion of 50mm dia complete all as specified and directed. |
| 86 | S&F rotational moulded polythene water storage tank of capacity 300 ltr double layers ISI marked of cylindrical/cubical vertical/horizontal shape with closed top cover of casted iron complete hoisted and fixed position & connecting up complete all as specified and directed. |
| 87 | S&F ball type foot valve of 150mm dia, 10/15 kg /sqm of make (ISI marked) as per IS 4038 in position at location including M&L for making flanged joints/screwed joints as existing and repair and making good to existing PCC surface complete all as specified and directed. |
| 88 | All as per Item No. 58 but 100 mm dia. |
| 89 | All as per Item No. 58 but 80 mm dia. |
| 90 | S&F for strainer 'Y' type of 150 mm dia of cast iron with stainless steel mesh of PN 1.0 for suction line complete all as specified and as directed. |
| 91 | All as per Item No. 61 but 100 mm dia. |
| 92 | All as per Item No. 61 but 80 mm dia. |
| 93 | Construction of brick masonry valve chamber in repair of size 1.20x 1.20 x 1.20M (internal diamension) (above GL 0.30 mtr) suitable for fixing of sluice valve, 15 cm thick foundation using PCC 1:4:8 type D-2 over 15 cm thick hardcore of broken stone, 23 cm thick brick walls built in cement and sand morter 1:4 15 cm thick intenal and external plaster including top of floor in cement and sand morter 1:3 15 mm thick, finished even and smooth without using extra cement 5 mm thick plate cover on 50 mm x 50mm 6mm MS angle frame embeded in PCC 1:2:4 type B-1 copping, having rectanglular, hinged, opening of size 150mm x 100 mm with locking arrangement, hold fast etc applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface and earth work in any type of soil including disposal of debries outside MD land complete all as specified and as directed. |
| 94 | S&F for Reciprocating chemical dosing pump, Chemical injecting calcium hypochlorite employed motor driven reciprocating chemical pump having upto 2 U.S GPD and adjustable high pressure of upto 100 psi with all connected accessories complete all as specified and as directed. |
| 95 | S&F for Altoch dosing system non- metalic solution tank of 100 ltr capacity with motor driven agitator to maintain uniform throughout the tank with all connected accessories complete all as specified and as directed. |
| 96 | Supplyinig and installation commissioning and testing of centrifugal pump (horizontal split casing type) set of 50 HP with CI impeller along with suitable capacity TEFC motor at 2900 RPM, 415 volts 50 Hz with coupling base guard and set of foundation bolts discharge 1000 LPM at 100 mtr head, complete alignment by manufacturer's rep complete all as specified and as directed. |
| 97 | Supply and installation, testing and commisioning, Monoblock pump set of 10 HP CI Impeller, sealing gland packing C-40 Shaft of discharge 871 lpm at 24 mtr head suitable for 415 volts 3 phase complete all as specified and as directed. |
| 98 | Supply and installation, testing and commisioning, Monoblock pump set of 12.5 HP CI Impeller, sealing gland packing C-40 Shaft of discharge 259 lpm at 75 mtr head suitable for 415 volts 3 phase complete all as specified and as directed. |
| 99 | Supply and installation, testing and commisioning, Monoblock pump set of 12.5 HP CI Impeller, sealing gland packing C-40 Shaft of discharge 1033 lpm at 23 mtr head suitable for 415 volts 3 phase complete all as specified and as directed. |
| 100 | S&F for double compression copper stainless steel gland for fixing armoured cable in panel suitable for size 4 core 25 to 35 sqmm complete all as specified and as directed. |
| 101 | S&F for double compression copper stainless steel gland for fixing armoured cable in panel suitable for size 4 core 6 to 16 sqmm complete all as specified and as directed. |
| 102 | Design, supply, install, test and comissioning of Starter Panel for pump of suitable size for indoor installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of 7 tank process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 300 ,Amps rating TPN bus bars of high conductivity aluminium alloy and half neutral with aluminium bus bar RYB insulated complete and shall be provided with colour coded heat shrinkaable sleeves,with with sufficient depth of the panel for accommodating all switchgears in the panel. The panel shall be modular/cubical trype with bus chamber cable ally and provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate, 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc (Note- Incoming and Outgoing MCCBs with connected items will be inclusive ). |
| 103 | For Incoming :-(a) 01 No – MCCB 4 POLE, 36 KA 415V Capacity 125 Amp (b) 01 No – Digital Voltmeter (0-500V) with selector switch(c) 01 No – Digital Ammeter (0-300Amps) with selector switch(d) 01 Set – Pilot lampFor Outgoing :-(a) 02 Nos - MCCB, TP (25KA) of 100 Amps capacity(b) 02 Nos - Fully automatic star delta starter with single phase preventor for 50 HP pump.(c) 2 Nos - Digital Ammeter (0-200 Amps) with CT & selector switch(d) 02 Nos - Caution board(e) All internal wiring suitable size FRLSH copper conductor, fuses, glands and connected necessary switchgears.(f) RYB lndicating LED type. (g) Danger Notice Board-01 No |
| 104 | Design, supply, install, test and comissioning of Starter Panel for pump of suitable size for indoor installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of 7 tank process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 200 ,Amps rating TPN bus bars of high conductivity aluminium alloy and half neutral with aluminium bus bar RYB insulated complete and shall be provided with colour coded heat shrinkaable sleeves,with with sufficient depth of the panel for accommodating all switchgears in the panel. The panel shall be modular/cubical trype with bus chamber cable ally and provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc (Note- Incoming and Outgoing MCCBs with connected items will be inclusive). |
| 105 | For Incoming :-(a) 01 No – MCCB 4 POLE, 36 KA 415V Capacity 63 Amp (b) 01 No – Digital Voltmeter (0-500V) with selector switch(c) 01 No – Digital Ammeter (0-300Amps) with selector switch(d) 01 Set – Pilot lampFor Outgoing :-(a) 02 Nos - MCCB, TP (25KA) of 40 Amps capacity(b) 02 Nos - Fully automatic star delta starter with single phase preventor for upto 12.5 HP pump.(c) 2 Nos - Digital Ammeter (0-200 Amps) with CT & selector switch(d) 02 Nos - Caution board(e) All internal wiring suitable size FRLSH copper conductor, fuses, glands and connected necessary switchgears.(h) RYB lndicating LED type(j) Danger Notice Board-01 No |
| 106 | S&F for Blank MCB plate complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender