Tender For Repair/ Maintenance Of Kero Cum Electric Water Heater, Geysers, Rewinding Of Ceiling Fan/Exhaust Fan/Wall Fan Incl All Connection Items At Various Locs Under The Aor Of Ge 969 Ews.
Tender Value
10 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
9 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Kero Cum Electric Water Heater, Geysers, Rewinding Of Ceiling Fan/Exhaust Fan/Wall Fan Incl All Connection Items At Various Locs Under The Aor Of Ge 969 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Repair and re-fixing, re-assembling the existing ceIling fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, painting fan blades, changing fan bearning, rewinding of fan, write MES no on fan blades, replacement of fan canopy (top/bottom cover) including nut, bolts and washers, complete all as specified and as directed. |
| 2 | S&F in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan, complete all as specified and as directed. |
| 3 | Repairing and servicing of the existing kerosene-cum-electric water heater, including inspection, cleaning and descaling of the heating tank, checking and repair of the kerosene burner assembly, fuel supply line, ignition system, electric heating element, thermostat, electrical wiring, switches and safety devices, as required. The work shall include replacement of defective or damaged parts, testing of the kerosene and electric heating systems, checking for fuel and water leakage, and commissioning of the unit to ensure safe and satisfactory operation, complete in all respects.Note: (a) The rates shall be inclusive of all labour, material, spare parts, tools required to complete the repair and commissioning of the unit |
| 4 | Repair and re-fixing, re-assembling the existing exhaust fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, changing fan bearning, rewinding, replacemnt of rubber bush/ anti vibration pads, mounting frame etc including nut, bolts and washers, complete all as specified and as directed. |
| 5 | Repair and re-fixing, re-assembling the existing Wall fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, changing fan bearning, rewinding of fan motor including nut, bolts and washers, complete all as specified and as directed. |
| 6 | S&F in repair capacitor suitable for wall fan, complete all as specified and as directed. |
| 7 | S&F in repair capacitor 2.5/3 mfd suitable for 250mm/350mm sweep exhaust fan, complete all as specified and as directed. |
| 8 | Supply and fix in replacement plug top 15 Amp, complete all as specified and as directed. |
| 9 | Supply and fix connecting cord 1.5 mtr length with plug top suitable for 1.5/2 KW Geysers, complete all as specified and as directed. |
| 10 | Supply and fix, install and testing ISI marked, metalic body, energy efficient, water heater storage type, copper tank, electgrically operated, single phase, 50 Hz (5 star rating), complete of 25 Ltr capacity with and including supply and fixing, wire armoured 450mm long, 15 mm dia brass coupler etc, flexible pipe suitable to withstand upto 100 degree celcius for hot and cold water, Anchor fastner - 04 Nos of suitable size , 3 core PVC insulated, FRLS multistranded copper conductor cable and plug top 15 Amps capacity, complete all as specified and as directed. |
| 11 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc, complete all as specified and as directed. |
| 12 | M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed. |
| 13 | S&F switch piano Flush type, single pole 16 amp 240 volts, complete all as specified and as directed. |
| 14 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed. |
| 15 | S&F in repair heating element of capcity 1.5KW (Round/Traingle), complete all as specified and as directed. |
| 16 | S&F in repair heating element of capcity 2KW (Round/Traingle), complete all as specified and as directed. |
| 17 | S&F Thermostate including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs including taking down existing unserviceable thermostate, complete all as specified and as directed. |
| 18 | Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc, complete all as specified and as directed. |
| 19 | S&F PVC connecting pipe 18\\"/24\\" long with brass adopters for cold/hot water and connecting up with complete for 25 /35 /50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe, complete all as specified and as directed. |
| 20 | S&F of Indicator lamp (Pilot lamp) Neon type of red, Green yellow color with rated voltage 220-240 V AC, 50 Hz suitable for indicating power on/ off status in geysers, complete all as specified and as directed. |
| 21 | S&F fusible plug melting at 90 - 100 degrees Centigrade including taking down existing uncerviceable fusible plug, complete all as specified and as directed. |
| 22 | S&F high pressure valve with dead weight suitable for 25 / 50 ltrs capacity Geysers including taking down existing unserviceable high pressure valve, complete all as specified and as directed. |
| 23 | S&F bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25 / 35 / 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers, complete all as specified and as directed. |
| 24 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150/200/250mm, complete all as specified and as directed. |
| 25 | S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly, complete all as specified and as directed. |
| 26 | M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg / Sq.cm, re-assembling of any capacity Geysers, complete all as specified and as directed. |
| 27 | Note:- Schedule of credit Rs 4550.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender