Tender For special Rep To Concertina Coil And Barbed Wire Fencing At Certain Locations And special Rep/Replacement Of Sewage Pump And Connected Works At Afs Tambaram (8965/E8)

Issued by Statutory Bodies & Commissions/Committees · Chengalpattu, Tamil Nadu
Tender Value
47.53 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
10 days left
EMD
95060
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Rep To Concertina Coil And Barbed Wire Fencing At Certain Locations And special Rep/Replacement Of Sewage Pump And Connected Works At Afs Tambaram (8965/E8)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Nov-2026 Corrigendum BOQ 01-Dec-2026

BOQ

Name of Work:- SPL REP TO CONCERTINA COIL AND BARBED WIRE FENCING AT CERTAIN LOCATIONS AND SPL REP/REPLACEMENT OF SEWAGE PUMP AND CONNECTED WORKS AT AFS TAMBARAM (8965/E8)
Sl. No. Item Description
1Taking up unserviceable centrifugal non clog submersiable sewage pump set 10HP from sewage sump by bail out the water, disconnecting , declamping, transport to authorised work shop as directed by Engineer-in- charge and re-installation in the sump,testing complete including replacement of Gasket,cable end cap, water/oil Seal,oil, painting and service charges etc.,lathe work as required complete and testing all as directed. (Make:-Kirloskar ) Location :Golden Jubilee & New sewage pump House .Note: Spare parts/ accessories like Winding charges,bearings,Seal,Sensors,Shaft etc., shall be measured and paid separately under relevant items of this schedule complete all as specified and directed by Engineer-in-Charge.
2Supply only the following spares of centrifugal non clog submersiable sewage pump set 10HP capacity complete all as specified and directed by Engineer-in-Charge.(a) Re-winding stator with with new copper wire of appropriate size of class-F insulation and including removing old burnt copper wire complete all as specified and directed by Engineer-in-Charge.
3(b) Bearing upper and lower complete all as specified and directed by Engineer-in-Charge..
4© M-seal lower and upper complete all as specified and directed by Engineer-in-Charge.
5(d) Temperature Sensor complete all as specified and directed by Engineer-in-Charge.
6(e) Moisture sensor complete all as specified and directed by Engineer-in-Charge.
7(f) Rotor Shaft complete all as specified and directed by Engineer-in-Charge.
8(g) O Ring complete all as specified and directed by Engineer-in-Charge.
9(h) Repalcement Insulating oil as per the manufacturer recommended grade complete all as specified and directed by Engineer-in-Charge.
10S&F in replacement contactor for Star Delta starter 440 volts, 50 Hz, 3 phase, AC, suitable for following HP of induction motors including taking out complete all as specified and directed by Engineer-in-Charge.(a) Upto16 Amps suitable for 7.5 / 10 HP complete all as specified and directed by Engineer-in-Charge.
11Supply and fix in replacement automatic star delta starter suitable for pump set, 3 phase AC motor capacity 7.5 to 15HP,built in overload relay,single phase preventor,AC3,4pole contactor,415 volt in heavy duty deep drawn sheet metal box including taking out complete all as specified and directed by Engineer-in-Charge.
12Supply and fix in replacement electronic overload relay suitable for submersible pump including taking out complete all as specified and directed by Engineer-in-Charge. (a) For 5 to 10HP complete all as specified and directed by Engineer-in-Charge.
13S&F in replacement No volt coil, 440 volt ,suitable for star delta starters up 7.5 to10 HP capacity including taking out complete all as specified and directed by Engineer-in-Charge.
14Supply,install and testing in replacement of Electric driven,415 Volts ,three phase, self priming non clog coupled pump set set of 25 HP,9.37 KW, including base frame, PCC platform as per manufactures design complete and taking down/dismantling of unserviceable existing pumpset and transport to MES stores for further BER/disposal action complete all as specified and directed by Engineer-in-Charge.
15Supply,install and testing in replacement of Electric driven,415 Volts ,three phase, self priming non clog coupled pump set set of 20 HP,9.37 KW, including base frame, PCC platform as per manufactures design complete and taking down/dismantling of unserviceable existing pumpset and transport to MES stores for further BER/disposal action complete all as specified and directed by Engineer-in-Charge.
16Supply and fixing in replacement of CI sluice valve of size 150 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers, 02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge.
17Supply and fixing in replacement of CI sluice valve of size 100 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers, 02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge.
18Supply and fixing in replacement of CI sluice valve of size 80 mm dia confirming to IS -14846 PN-1.6 non raising type both ends flanged with SS spindle including jointing materials such as nuts, bolts washers,02Nos addl GI valve flanges to fix in PP-R pipes and 3mm rubber gasket 02 Nos complete all as specified and directed by Engineer-in-Charge.
19Supply and replacement of CI Non Return / foot valve with strainer PN 1.6 having one side flanged end joint suitable size of 100 mm dia including jointing materials such as nuts, bolts washers 02Nos and 3mm rubber gasket complete all as specified and directed by Engineer-in-Charge.
20Supply and replacement of CI Non Return/ foot valve with strainer PN 1.6 having one side flanged end joint suitable size of 80 mm dia including jointing materials such as nuts, bolts washers 02Nos and 3mm rubber gasket complete all as specified and directed by Engineer-in-Charge.
21Supply and laying in trenches/ floor Ductile Iron spigot and socket pipes as per IS:8329/2000 Class K7 including EPDM rubber gasket suitable for push on rubber gasket joint with inside cement mortar lining and outside Zinc bitumen coating of size 100mm dia to connect main pipe lines complete all as specified and directed by Engineer-in-Charge.
22Supply and laying in trenches / floor Ductile Iron spigot and socket pipes as per IS:8329/2000 Class K7 including EPDM rubber gasket suitable for push on rubber gasket joint with inside cement mortar lining and outside Zinc bitumen coating of size 150mm dia to connect main pipe lines complete all as specified and directed by Engineer-in-Charge.
23Supply and fix Rubber Gasket joints suitable for 150mm dia DI pipe including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge.
24Supply and fix Rubber Gasket joints suitable for 100mm dia DI pipe including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge.
25Supply and fix Rubber Gasket joints suitable for 80mm dia DI/PP-R pipe including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge.
26M&L for CI/DI/PP-R fittings like Connecting pieces one end flanged and other ocket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth up to 150mmdia including jointing and jointing materials complete all as specified and directed by Engineer-in-Charge.
27Supply and fix in repair galvanised iron bolt,nut and washers of any dia and length as required at site and MS support brackets, clambs etc complete all as specified and directed by Engineer-in-Charge.
28Supply and lay 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11UV stablised and antimicrobial fusion welded having thrmal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene all type of fittings compete laid in trenches of size of outer dia 110mm pipe, including necesary fittings flanges, tees, unions, sockets etc complete all as specified and directed by Engineer-in-Charge.
29Supply and lay 3 layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11UV stablised and antimicrobial fusion welded having thrmal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene all type of fittings compete laid in trenches of size of outer dia 90mm pipe, including necesary fittings flanges, tees, unions, sockets etc complete all as specified and directed by Engineer-in-Charge.
30Supply and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6sq mm 2 core - for security lights, gate light etc complete all as specified and directed by Engineer-in-Charge.
31Material and labour for DWC HDPE pipe of size 90/76 mm bore (OD X ID) for LT UG cable protection complete all as specified and directed by Engineer-in-Charge.
32M & L in replacementfor Sub main wiring complete with four runs of 10.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth contuinuity conductor, drawn through and including suitable size of non metallic rigid PVC conduits and conduit accessories surface for taking connection from existing panels all as specified and as directed. [NOTE :- 4 runs of 10.0 sqmm cable, 1run of 10.0 sqmm copper conductor cable and 1 run of PVC conduit shall be measured as one length/running metre for pumping set connections complete all as specified and directed by Engineer-in-Charge.
33M&L for Design,Fabrication,install,commissioning and testing of LT cubical motor control panel board of suitable size as directed, three phase 4-wire systems, out door type, made out of CRCA sheet 3.0 mm thick, powder coated, with locking arrangements,mounted on 50x50x6mm angle iron frame complete suitable to accommodate and including the following:- (a) Automatic water level controller with LED indication for well water pumping system with intelligence features like level indication, auto/manual mode operation with By-pass options,dry-run protection, voltage surge protection,voltage level indications and fill options, in built power ON-OFF relay with three phase,440V AC supply,30 Amps power capacity suitable for pumps used for industrial purpose complete all as specified and directed by Engineer-in-Charge.(b) Six core multi stranded copper conductor 1.0 Sqmm from well to panel box-50mtr (Approx) complete all as specified and directed by Engineer-in-Charge.Note:- (i) Additional Six core multi stranded copper conductor 1.0 Sqmm length required more than 50 Mtr shall be measured and paid separately under relevant items complete all as specified and directed by Engineer-in-Charge.
34Supply and fix multi stranded copper conductor 1.0 Sqmm, 6 core from well to panel box all as directed complete all as specified and directed by Engineer-in-Charge.
35Supply and fix in replacement of gate valve, PP-R Gate valves(Brass insert) asper requirement of site for pipe 90mm size complete all as specified and directed by Engineer-in-Charge.
36M & L for cutting of existing road/ floor/ plinth/drain for taking out/ laying of cable/ GI/ PP-R pipes line including necessary earth work excavation and making good to match with existing surface with PCC 1:4:8 type C1 by (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
37M&L for Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in foundation / grouting / valve chamber etc complete all as specified and directed by Engineer-in-Charge.
38M & L for taking up or down from trenches for old rusted/ damaged CI/GI/ PVC Pipe including fittings and branch connections if any for removal to stores for further disposal of following dia complete all as specified and directed by Engineer-in-Charge.(a) CI 150 mm dia complete all as specified and directed by Engineer-in-Charge.
39(b) GI 100 mm dia complete all as specified and directed by Engineer-in-Charge.
40(c) GI 80 mm dia complete all as specified and directed by Engineer-in-Charge.
41Supply,fabricate and fixing in replacement of mild steel structures including necessary cutting,welding etc for making water fillig points and other plateforms works,supports for installation of pump sets in shallow wells with channels,angles,flat irons including bolt nut washers etc including applying two coats of synthetic enamel paint overa a coat of red oxide primer and taking down complete all as specified and directed by Engineer-in-Charge.
42M&L in replacement of Starter panel for 15 HP Open well pump house centrifugal pump set motor,Three phase, electronic control Panel with digital volt meter, amps meter, single phase preventor protection, thermal over load & electronic dry run protection, high/ low voltage cutt off, RYB indications, On-Off timer complete including MCCB 63Amps, 4Pole, 415 volts,16KA in sheet metal enclosure wall/ grouting on floor with proper fixing arrangements and connection with single core PVC insulated copper conductor, 10.0sqmm complete all as specified and directed by Engineer-in-Charge.
43Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to GI earth strip of size 32 X 6 mm by means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part- I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 100mm centre to centre with suitable handle, watering pipe 20mm dia medium grade pipe with funnel and 40mm dia light grade as protection pipe, charcoal, salt etc connected to earthing test point all as specified including testing and commissioning on complete all as specified and directed by Engineer-in-Charge.
44Supply and fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof onductors and down conductors above ground for earthing complete all as specified and directed by Engineer-in-Charge.
45Taking out old unserviceable LT under ground cable in sizes from the trench / floor and staking properly for credit complete all as specified and directed by Engineer-in-Charge.
46Taking out old unserviceable submain wiring and copper connecting cable in sizes from the wall / floor etc. and staking properly for credit complete all as specified and directed by Engineer-in-Charge.
47M&L for cutting the existing the pipe and insert the pipe / branches for fixing the PP-R pipes / DI pipes / Flow meters complete with proper jointings and jointing materials etc. all as specified and directed.
48Supply and fixing in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down the old US one for credit complete all as specified and directed by Engineer-in-Charge.
49Excavation in trenches not exceeding 1.5 M width and not exceeding 1.5 mtr depth and getting out soft/loose soil for laying of cables and pipe line all as specified.
50Returning filling after ridding in inlcuding spreading levelling watering well ramming in layers not exceeding 25 cm thick obtained from excavation complete all as specified and directed by Engineer-in-Charge.
51Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified and directed by Engineer-in-Charge.
52Dismantling RCC fencing posts or struts of any section embedded in concrete/brick masonry including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge.
53S&F in repairs galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings andstraining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc, complete all as specified and directed by Engineer-in-Charge. (each line wire to be measured)
54Restraining, resecuring including making good galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings andstraining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc, complete all as specified and directed by Engineer-in-Charge. (each line wire to be measured)
55Demolition of brick work or stone/ boulder /PCC block masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed by Engineer-in-Charge.
56Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick (Below or above ground level) complete all as specified and directed by Engineer-in-Charge.
57M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregated) as in coping, cills, steps, bands, bed plate, benching to manholes and drains etc including necessary form work complete all as specified and directed by Engineer-in-Charge.
58M & L for pre-cast cement concrete block masonry with solid blocks 1:3:6 Type C1(using 20mm graded stone aggregate) exc. 10 cm in width and setting in mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
59M&L for rendering 15mm thick on brick work or concrete surface of walls in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
60M&L for preparation of new plastered surfaces and applying two coats of cement based paint over a Coat alkaliresistant priming paint on walls complete all as specified and directed by Engineer-in-Charge.
61S&F in repairs of concertina coil fencing made from high tensile spring steel, high Carbon wire conforming to IS-4454 duly hot Dipped Galvanished as per IS -4826 with 230GSM, 600mm dia, 10 Metre openable length, with galvanished coating and punched tape material as per IS-513, having 30-35 Nos rounds per 6 mtr length (before streaching) having medium barbs fixed to the existing mild steel post over the boundray wall upto height 3m complete all as specified and as directed by Engineer-in-Charge.Note: Horizontal barbed wire & angle iron support shall be measured and paid sepately under relevent items of Schedule \\"A\\". Measurement shall be made for stretched length complete all as specified and directed by Engineer-in-Charge.
62Demolition of Concrete (Reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge.
63M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Cover slab for manholes etc set in cement mortor 1:6 including use and waste necessary form work (Reinforced shall be measured and paid seprately) complete all as specified and directed by Engineer-in-Charge.
64M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than .9mm dia or securing clips complete all as specified and directed by Engineer-in-Charge.
65Ditto as item no 64 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
66Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
67S & F Mild steel work Angles, bars, flats etc. as in fencing post struts including cutting tops to shape as directed including embedding in concrete and all necessary drilling holes, bolting or riveting , welding notching for wire and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
68M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling & mass concrete for post/pillars etc incl formwork complete all as specified and directed by Engineer-in-Charge.
69M&L for broken glass coping on top of wall setting in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
70M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
71Dismantling fencing wire mesh of any type & description complete all as specified and directed by Engineer-in-Charge.
72Supply only MS galvanised chain link fencing haevy zinc coated (Hot dip), aparture size 50mm and wire of 3 to 4 mm dia complete all as specified and directed by Engineer-in-Charge.
73Fixing only chain link fencing any mesh size and type to any type of standard, rails, iron angle posts, straining bolts etc incl provision of binding wire complete all as specified and directed by Engineer-in-Charge.
74S & F mild steel screw bolts of 11 to 15mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and not exc 10cm complete all as specified and directed by Engineer-in-Charge.
75M&L for MS round bars, 10mm dia & over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed by Engineer-in-Charge.
76M & L for preparation of new or previously untreated steel surfaces of any description, not exc. 10 cm width or girth, not otherwise described when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
77M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to including joining welding and connecting each other to form a cage for water tanks Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
78Demolition of cement concrete (reinforced) as in roof, floors (other than ground floor) beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
79Demolition of cement concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
80M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Cover slab for manholes etc set in cement mortor 1:6 including use and waste necessary form work (Reinforced shall be measured and paid seprately) complete all as specified and directed by Engineer-in-Charge.
81Taking down cement plaster any description on brick or stone walls, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
82M&L for 10mm thick in CM 1:6 rendering on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed by Engineer-in-Charge.
83M&L for Rendering 5mm thick in CM 1:3 as in ceilings concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed by Engineer-in-Charge.
84Supply only Liquid water proofing compound as complete all as specified and directed by Engineer-in-Charge.
85M&L for preparation of new plastered surfaces of walls three coats of white wash complete all as specified and directed by Engineer-in-Charge.
86M & L preparation of new surfaces of walls plastered or unplastered etc and applying two coat of cement based paint paint on wall surfaces complete all as specified and directed by Engineer-in-Charge.
87M&L for praparation of newly plastered surfaces and applying Three coats of White wash on Ceiling complete all as specified and directed by Engineer-in-Charge.
88M & L for PCC type D2 1:4:8 ( using 40mm graded stone aggregate) in foundations, filling and mass Concrete complete all as specified and directed by Engineer-in-Charge.
89Providing, fabricating, supplying, fixing and commissioning Stainless Steel (Grade SS 304) Manual Bar Screen for STP/Sewage sump cum pump house Bar Screen Chamber, fabricated from SS 304 flats 50 × 6 mm placed vertically at 20 mm clear spacing as directed, welded to SS 304 angle frame 50 × 50 × 6 mm complete with intermediate stiffeners, lifting handle, guide channels, anchor fasteners, SS bolts, nuts and washers. The screen shall be installed at an inclination of 45° to the horizontal, complete with hand-operated cleaning rake, all welding using SS electrodes, grinding and polishing of welds, proper alignment, fixing in position, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58469266
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.53 Lakhs
LAST DATE 01-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Rep To Concertina Coil And Barbed Wire Fencing At Certain Locations And special Rep/Replacement Of Sewage Pump And Connected Works At Afs Tambaram (8965/E8)
Basic Detail
Tender No GE(AF)/TBM/8965/E8
Bidding Type Tender
Location
City Chengalpattu
State Tamil Nadu
Key Dates
Publish Date 18 Nov 2026
Submission Date 01 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 47.53 Lakhs
Tender Fee 500
EMD 95060
Exemption Available
Document List
227f367d-551f-4d19-bc46-c4205f0d15ba.html
BOQ_895372.xls
PS.pdf
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 10 days
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

227f367d-551f-4d19-bc46-c4205f0d15ba.html

xls

BOQ_895372.xls

pdf

PS.pdf

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender