Tender For special Replacement Of Sewage Lines, Repair Of Manholes And Allied Wk In Aor Of Sw Div At The Inf School And Certain Revenue & Minor Work At Mh Mhow And Stn Hq Mhow Under Ge (Mis) Mhow
Tender Value
34.24 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
9 days left
EMD
68500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Indore → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Replacement Of Sewage Lines, Repair Of Manholes And Allied Wk In Aor Of Sw Div At The Inf School And Certain Revenue & Minor Work At Mh Mhow And Stn Hq Mhow Under Ge (Mis) Mhow
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning and clearing the blockage of sewage lines, of any dia, type and any depth, removing any type of blockage by mechanical means or by flushing water with pressure pump from manholes, complete all as specified and directed by the Engineer-in-Charge.Note: The contractor shall ensure necessary safety precautions, PPE, barricading, gas testing, proper ventilation and confined-space safety arrangements during execution. Sludge and effluent shall be transported in sealed tankers/containers and disposed of at authorised locations as per applicable safety and environmental regulations. |
| 2 | Taking out solid/semi-solid sludge from existing manhole of any size and any depth by suitable mechanical means using sludge suction machines, vacuum tankers, dewatering pumps or other appropriate mechanical equipment, including removal of sludge water, burying the entire sludge/sludge water in an excavated pit of adequate size, including excavation and covering with earth, or disposing of the same in covered vehicles outside the periphery of defence land to a distance exceeding 1 km, including taking off RCC/iron manhole covers and refixing the same after cleaning, complete as specified and directed by the Engineer-in-Charge.Note: The contractor shall ensure necessary safety precautions, PPE, barricading, gas testing, proper ventilation and confined-space safety arrangements during execution. Sludge and effluent shall be transported in sealed tankers/containers and disposed of at authorised locations as per applicable safety and environmental regulations. |
| 3 | Removing existing CI/RCC manhole covers of any type, shape or size (rectangular/circular) and carrying out de-sludging, de-watering, cleaning and flushing of septic tanks and soakage wells of any size and depth by suitable mechanical means using hydraulic jet pressure machines, sludge suction machines, vacuum tankers and dewatering pumps, including plugging of inlet pipes wherever required, removal of accumulated sludge, solid/semi-solid waste and effluent, thorough cleaning of internal surfaces and making the tanks/wells fully functional, collecting and transporting the extracted sludge and effluent outside the periphery of defence land in properly covered/closed containers or tankers, and reinstating the manhole covers to their original positions after completion of work, complete to the entire satisfaction of the Engineer-in-Charge.Note: The contractor shall ensure necessary safety precautions, PPE, barricading, gas testing, proper ventilation and confined-space safety arrangements during execution. Sludge and effluent shall be transported in sealed tankers/containers and disposed of at authorised locations as per applicable safety and environmental regulations. |
| 4 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in any type of soil complete all as specified and directed. |
| 5 | All as per item No 4.00 above but exc 1.5m but n.exc 3.0m in depth. |
| 6 | Returing filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick of any type of soil complete all as specified and directed. |
| 7 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 8 | Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC) 150mm dia jointed in cement mortar and taking out of trenches and removing the debris including concrete bed and haunching from the trenches complete all as specified and directed. |
| 9 | Demolition by breaking up drain pipes (salt glazed stoneware or AC/RCC) 200mm dia jointed in cement mortar and taking out of trenches and removing the debris outside defence land including concrete bed and haunching from the trenches complete all as specified and directed. |
| 10 | M&L for 150mm bore/inner dia rat proof/anti rodent Double wall corrugated (DWC) pipe (SN-8) with intergral socket and clamps and all necessary fttings, laid in trenches jointed as per manufacturer instruction confirming to IS 16098 (Part 2) complete all as specified and directed |
| 11 | M&L for 200mm bore/inner dia rat proof/anti rodent Double wall corrugated (DWC) pipe (SN-8) with intergral socket and clamps and all necessary fttings, laid in trenches jointed as per manufacturer instruction confirming to IS 16098 (Part 2) complete all as specified and directed |
| 12 | M&L for 150mm internal dia salt glazed stone ware drain pipe Class A laid in trenches on concrete bedding jointed in cement mortar 1:1 complete all as specified and directed. |
| 13 | M&L for 200mm internal dia salt glazed stone ware drain pipe Class A laid in trenches on concrete bedding jointed in cement mortar 1:1 complete all as specified and directed. |
| 14 | M&L for Reinforced concrete pipes, class NP-2, laid and jointed complete with collars 150 mm dia complete all as specified and directed. |
| 15 | M&L for Reinforced concrete pipes, class NP-2, laid and jointed complete with collars 200 mm dia complete all as specified and directed. |
| 16 | M&L for concrete bed to drain pipes of bore 150mm dia including packing under hunching against the sides of pipe after they are laid in cement concrete 1:4;8 type C-2 using 40mm graded stone aggregates complete all as specified and directed. |
| 17 | M&L for concrete bed to drain pipes of bore 200mm dia including packing under hunching against the sides of pipe after they are laid in cement concrete 1:4;8 type C-2 using 40mm graded stone aggregate complete all as specified and directed. |
| 18 | Demolition of brick works built in cement mortar including all quoins pillars arches etc including PCC benching/coping etc complete all as specified and directed. |
| 19 | M&L for brickwork with fly ash bricks modular size,straight or curved on plan exc 6m mean radious,built in cement mortar 1:4 complete all as specified and directed. |
| 20 | M&L for brick work with subclass ‘B’ bricks modular size, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 21 | All as per item 20.00 above but except brick |
| 22 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius in half brick thick, built in CM (1:4) complete all as specified and directed. |
| 23 | M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius in one brick thick honey comb walling, built in CM (1:4) complete all as specified and directed. |
| 24 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and removing unserviceable material outside cantt area all as specified and directed by Engr-in-Charge. |
| 25 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate as in Manhole channel and surface drain slightly rounded or chamfered angles etc complete all as specified and directed. |
| 26 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching, coping etc including necessary form work complete all as specified and directed. |
| 27 | Taking down cement plaster of any description on brick or stone walls or from concrete surface incl raking out joints, hacking for key,scrubbing down with water and removing unserviceable material outside cantt area all as specified and directed by Engr-in-Charge. (Note: Plaster work may be in patches upto triple storey) |
| 28 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface fininished even and smooth without using extra cement including mixing of integral water proofing compound in the proportion as per manufacturers instructions complete all as specified and directed. |
| 29 | Supply only integral water proofing compound complete all as specified and directed. |
| 30 | S&F in repairs PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls including clamp & cowl complete all as specified and directed. |
| 31 | S&F in repais PVC bends 110mm bore, any radius complete all as specified & directed. |
| 32 | M&L for loose filling with aggregate of gauge 80 to 150mm of broken bricks complete all as specified & directed. |
| 33 | S&F in repair PVC gully trap ( SWR ) bends 125/110mm setting & jointing with solvent cement complete all as specified & directed. |
| 34 | Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) complete all as specified and directed. |
| 35 | M&L for pre-cast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole/SW/ST cover slab fixed in position including necessary form work and set in CM 1:4 complete all as specified and directed.(Reinforcement will be measured and paid separetly) |
| 36 | S&F mild steel TMT 10mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 37 | S&F mild steel TMT bars 6 to 8mm dia cut to length bent to shape required including cranking bending spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 38 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons, platform etc. complete including removal of demolition material to store or from site all as specified and directed. |
| 39 | M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and fair finish complete including filling the joints with mastic compound complete all as specified and directed |
| 40 | M&L for chequered coloured cement concrete tiles 40cm x 40cm x 25mm thick, set, jointed and pointed in cement slurry in floors with grey pigment cement and pigments over and including 15mm thick screed bed or bedding layer of CM 1:4 set and jointed in neat cement slurry and pointed in white or colored cement to match the surface of tiles finish complete all as specified and directed. |
| 41 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade with approved colour ,design & pattern as in footpath,parks,lawns,drive way or light traffic parking ect.,of required strength, thickness & size/ shapeand including 40 mm thick compacted bed of fine sand, compacting and proper embedding /laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand and cutting of paver blocks as per required size and pattern,packing at edge,finishing,and sweeping extra sand complete all as specified and directed. |
| 42 | M&L for cement concrete in type C-2, 1:3:6 (using 40mm graded stone aggregate) as in fundation filling, mass concrete, sub base etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 43 | M&L for cement concrete in type C-2, 1:3:6 (using 40mm graded stone aggregate) as in fundation filling, mass concrete, sub base etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents