Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #58469242

Tender For Repair/ Replacement Of Hepa Filters (Half-Yearly) For Different Ots Incl Suction And Discharge Filters With Misc Works And Repair/ Maintenance Of Ot Lights With Connected Work At Chaf Banglaore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Nov 2026
16 days left
EMD
74600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Hepa Filters (Half-Yearly) For Different Ots Incl Suction And Discharge Filters With Misc Works And Repair/ Maintenance Of Ot Lights With Connected Work At Chaf Banglaore

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF HEPA FILTERS (HALF-YEARLY) FOR DIFFERENT OTs INCL SUCTION AND DISCHARGE FILTERS WITH MISC WORKS AND REPAIR/ MAINT OF OT LIGHTS WITH CONNECTED WORK AT CHAF BANGLAORE
Sl. No. Item Description
1Comperenensive maintainence and servicing of following mentioned OT light fittings including control panel and all connected items and carrying out routine check of OT lights for smooth functioning all as per manufacturer's instructions as and when directed incl entire satisfaction of Engr-in-charge complete all as specified and as directed by Engr-in-charge.Notes: (i) Unserviceable spares which are required to be replaced shall be measured and paid seperately under relevant items of schedule.(ii) Authorized personnel shall repair the unit.(iii) Clean the light housing and arm using mild soap and water mixture. Apply this mixture to a clean cloth and wipe down the light head and arm.(iv) Check front lens and optics to assure there are are no chips, cracks or other.(v) Check that all mounting and attachment screws washers etc., are in place and securely tightened. Replace any missing screws and retighten as required.(vi) Ensure that casters are seated properly on the base assembly.(vii) Check to make sure all moving joints function properly along the mounting system and head and arm system.
2OT-I (Two Lights)
3OT-II (Two Lights)
4OT-III (Two Lights)
5OT-IV (Two Lights)
6OT-V (Two Lights)
7OT-VI (Two Lights)
8OT-CTVS (Two Lights)
9Gynaec OT Labour Room
10Minor OT Mortuary OT
11Vascular OT
12Dismantling the square arm from ceiling, removing of spring arms and replacement of old rusted base plates, foundation bolts, nuts and make necessary and proper alignment of complete OT light fittings and reinstallation of the complete OT light fitting including accessories complete all as specified and as directed by Engr-in-charge.
13Supply and fix in replacement of Control Board (PCB) of OT light fitting as per existing complete all as specified and as directed by Engr-in-charge.
14Supply and fix in replacement of switching mode power supply (SMPS) complete all as specified and as directed by Engr-in-charge.
15Supply and fix in replacement of reusable sterile handle complete all as specified and as directed by Engr-in-charge.
16Supply and fix in replacement of Lower Arm Assembly complete all as specified and as directed by Engr-in-charge.
17Supply and fix in replacement of LED 50 US FDA registered round shaped Double Dome OT light with following specifications complete all as specified and as directed by Engr-in-charge.(a) Light Intensity in 1m distance - 00000-160000 lux(b) Colour Temp- 4500 K(c) Colour Rendition Index (Ra)-95(d) Colour Rendition Index (R9) - 95(e) Spot Diameter (mm) - 130-300 mm (adjustable)(f) No of LEDs - 48(g) Ambient light Intensity 300 lx(h) Service Life of LEDs - Approx 50000 Hrs(j) Temp at Surgeon's Head - < 1 degree
18Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length.
19Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length.
20Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 4 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 4 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length.
21Supply and fix in replacement of sub main wiring with four single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and four runs of copper conductor together taken as one length for measuring unit length.
22Supply and fix sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and double door with IP-43 and IK 09 protection along with cable end box for above DB and flush to wall including all cutting / civil work etc., in wall as required complete all as specified and as directed by Engr-in-charge.
23Supply and fix MCB SPN 40/ 63 Amps, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge.
24Supply and fix MCB SP, AC, 240 volts of 6 to 32 Amps capacity 'C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information
25Supply and fix MCB SP, AC, 240 volts of 6 to 32 Amps capacity 'C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58469242
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 30-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Hepa Filters (Half-Yearly) For Different Ots Incl Suction And Discharge Filters With Misc Works And Repair/ Maintenance Of Ot Lights With Connected Work At Chaf Banglaore
Basic Detail
Tender No 8612/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 09 Nov 2026
Submission Date 30 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 74600
Exemption Available
Document List
7ac2db45-362f-4a6e-a4d4-14ec72025d4e.html
BOQ_895166.xls
SOC8612.pdf
Tenderdocuments8612.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

7ac2db45-362f-4a6e-a4d4-14ec72025d4e.html

xls

BOQ_895166.xls

pdf

SOC8612.pdf

pdf

Tenderdocuments8612.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender