Tender For Repair/ Replacement Of Hepa Filters (Half-Yearly) For Different Ots Incl Suction And Discharge Filters With Misc Works And Repair/ Maintenance Of Ot Lights With Connected Work At Chaf Banglaore
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Nov 2026
16 days left
EMD
74600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Hepa Filters (Half-Yearly) For Different Ots Incl Suction And Discharge Filters With Misc Works And Repair/ Maintenance Of Ot Lights With Connected Work At Chaf Banglaore
BOQ
| Sl. No. | Item Description |
| 1 | Comperenensive maintainence and servicing of following mentioned OT light fittings including control panel and all connected items and carrying out routine check of OT lights for smooth functioning all as per manufacturer's instructions as and when directed incl entire satisfaction of Engr-in-charge complete all as specified and as directed by Engr-in-charge.Notes: (i) Unserviceable spares which are required to be replaced shall be measured and paid seperately under relevant items of schedule.(ii) Authorized personnel shall repair the unit.(iii) Clean the light housing and arm using mild soap and water mixture. Apply this mixture to a clean cloth and wipe down the light head and arm.(iv) Check front lens and optics to assure there are are no chips, cracks or other.(v) Check that all mounting and attachment screws washers etc., are in place and securely tightened. Replace any missing screws and retighten as required.(vi) Ensure that casters are seated properly on the base assembly.(vii) Check to make sure all moving joints function properly along the mounting system and head and arm system. |
| 2 | OT-I (Two Lights) |
| 3 | OT-II (Two Lights) |
| 4 | OT-III (Two Lights) |
| 5 | OT-IV (Two Lights) |
| 6 | OT-V (Two Lights) |
| 7 | OT-VI (Two Lights) |
| 8 | OT-CTVS (Two Lights) |
| 9 | Gynaec OT Labour Room |
| 10 | Minor OT Mortuary OT |
| 11 | Vascular OT |
| 12 | Dismantling the square arm from ceiling, removing of spring arms and replacement of old rusted base plates, foundation bolts, nuts and make necessary and proper alignment of complete OT light fittings and reinstallation of the complete OT light fitting including accessories complete all as specified and as directed by Engr-in-charge. |
| 13 | Supply and fix in replacement of Control Board (PCB) of OT light fitting as per existing complete all as specified and as directed by Engr-in-charge. |
| 14 | Supply and fix in replacement of switching mode power supply (SMPS) complete all as specified and as directed by Engr-in-charge. |
| 15 | Supply and fix in replacement of reusable sterile handle complete all as specified and as directed by Engr-in-charge. |
| 16 | Supply and fix in replacement of Lower Arm Assembly complete all as specified and as directed by Engr-in-charge. |
| 17 | Supply and fix in replacement of LED 50 US FDA registered round shaped Double Dome OT light with following specifications complete all as specified and as directed by Engr-in-charge.(a) Light Intensity in 1m distance - 00000-160000 lux(b) Colour Temp- 4500 K(c) Colour Rendition Index (Ra)-95(d) Colour Rendition Index (R9) - 95(e) Spot Diameter (mm) - 130-300 mm (adjustable)(f) No of LEDs - 48(g) Ambient light Intensity 300 lx(h) Service Life of LEDs - Approx 50000 Hrs(j) Temp at Surgeon's Head - < 1 degree |
| 18 | Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length. |
| 19 | Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length. |
| 20 | Supply and fix in replacement of sub main wiring with two single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 4 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 4 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and two runs of copper conductor together taken as one length for measuring unit length. |
| 21 | Supply and fix in replacement of sub main wiring with four single core PVC insulated FRLSH cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including heavy grade PVC casing and caping of suitable size and its accessories with fixing arrangements on surface, wall, floor or ceiling etc., including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed by Engr-in-charge.Note: One run of earth continuity conductor, one run of PVC casing capping and four runs of copper conductor together taken as one length for measuring unit length. |
| 22 | Supply and fix sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and double door with IP-43 and IK 09 protection along with cable end box for above DB and flush to wall including all cutting / civil work etc., in wall as required complete all as specified and as directed by Engr-in-charge. |
| 23 | Supply and fix MCB SPN 40/ 63 Amps, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge. |
| 24 | Supply and fix MCB SP, AC, 240 volts of 6 to 32 Amps capacity 'C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 25 | Supply and fix MCB SP, AC, 240 volts of 6 to 32 Amps capacity 'C' curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysDec 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender