Tender For Addn / Altn To Footpath Interlocking Tiles & Drain In Domestic Area Of Mcc, Addn / Altn To Main Gate Entrance With Improvement To Electrical Infrastructure Of Transformer Of 1 Afsr, Provn Of Kota Stone Tiling Work With Renovation Of Gate A

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
31.90 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
17 days left
EMD
63800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn / Altn To Footpath Interlocking Tiles & Drain In Domestic Area Of Mcc, Addn / Altn To Main Gate Entrance With Improvement To Electrical Infrastructure Of Transformer Of 1 Afsr, Provn Of Kota Stone Tiling Work With Renovation Of Gate At Bldg No. P-19 In Domestic Area Of Mcc, Provn Of Tiles At Certain Places Of Bldg No. P-18 In Domestic Area Of Mcc And Provn Of Interlocking Tiles Path At Airmen Mess In Domestic Area Of Mcc Under Age B/R-Ii At Ge (Af) Palam Delhi Cantt

BOQ

Name of Work:- ADDN / ALTN TO FOOTPATH INTERLOCKING TILES & DRAIN IN DOMESTIC AREA OF MCC, ADDN / ALTN TO MAIN GATE ENTRANCE WITH IMPROVEMENT TO ELECTRICAL INFRASTRUCTURE OF TRANSFORMER OF 1 AFSR, PROVN OF KOTA STONE TILING WORK WITH RENOVATION OF GATE AT BLDG NO. P-19 IN DOMESTIC AREA OF MCC, PROVN OF TILES AT CERTAIN PLACES OF BLDG NO. P-18 IN DOMESTIC AREA OF MCC AND PROVN OF INTERLOCKING TILES PATH AT AIRMEN MESS IN DOMESTIC AREA OF MCC UNDER AGE B/R-II AT GE (AF) PALAM DELHI CANTT
Sl. No. Item Description
1Demolition of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed.
2M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
3M&L for brick work with sub class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) but except bricks complete all as specified and as directed. Note:- Old bricks shall be retrieved from ser item No. 1 here in before.
4M&L for brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, in half brick thick wall built in CM (1:4) complete all as specified and as directed.
5Taking down cement plaster or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and as directed.
6Demolition of concrete in ground floor and pavings n. exc 15cm thickness below or above ground level complete all as specified and as directed.
7M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4), to be finished even and smooth without using extra cement complete all as specified and as directed.
8M&L for cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in copings, bed plates, including necessary use and waste of form work kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engr-in-Charge.
9M&L for plain cement concrete (1:2:4), type B-2 (using 40mm graded crushed stone aggregate) as in surface channel, drain and bedding including necessary use and waste of form work and weathering, slightly rounded or chamfered angles complete all as specified and as directed.
10M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick including watering and ramming upto a true surface complete all as specified and as directed.
11M&L for 75 mm thick cement concrete (1:4:8) type D2, (using 40mm graded stone aggregate) as in sub base, surface to be finished even and fair complete including use and waste of necessary form work complete all as specified and as directed.
12M&L for Durastone heavy duty tiles of size (600 x 600)mm x 10mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the colour of the tiles, over and including 15mm thick cement mortar screed bed in CM (1:6) complete all as specified and as directed.
13S&F machine pressed precast concrete interlocking paver block (glossy finish coloured) 60mm thick M-35 grade of any shape and size, with grey cement and pigment to match, conforming to IS 15658-2006 with and including laid over 50mm thick sand cushioning complete all as specified and as directed.
14S&F precast cement concrete designer tiles 22 to 25mm thick glossy finish, heavy duty of approved brand and manufacturer and required shape and size as approved by GE with and including over 15mm thick screed bed in CM (1:6) including pointing with coloured cement to match the shade of tiles complete all as specified and as directed by Engineer-in-Charge. Note for ser item No 12, 13 & 14:- (i) Rates also includes in this item for necessary raking, circular cutting or notching and waste on tiles and necessary scaffolding etc. (ii) Shade/colour /pattern / fixing diagram of the tiles shall be approved by GE/Engineer-in-Charge.
15M&L for reinforced concrete pipes 300mm dia, class NP-3, laid and jointed complete including collars complete all as specified and as directed by Engr-in-Charge.
16M&L for concrete bed to drain pipes including haunching against the sides of pipes after they are laid and tested in cement concrete (1:4:8) type D-2 for 300mm dia pipe complete all as specified and as directed.
17Excavation in trenches not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth for foundation etc and getting out in soft / loose soil complete all as specified and as directed.
18Returning, filling in, including watering and well ramming in layers not exceeding 15cm thick complete all as specified and as directed.
19Removing of excavated materials to a distance exceeding 1.5 Km but not exc. 5 Km and depositing where directed complete all as specified and as directed.
20M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
21M&L for prepration of new /old surface of plaster and applying two coats of cement base paint over a coat of primer on wall complete all as specified and as directed.
22S&F in repairs, SFRC drain cover of size (1000mm x 500mm) x 70mm thick laid over existing drain complete all as specified and as directed by Engr-in-Charge. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete.(b) M/s KK Manhole.(c) Or equivalent
23M&L for prepration of new /old surface of plaster and applying three coats of white wash on wall complete all as per specified and as directed.
24Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
25M&L for dark coloured / printed / highlighter digital ceramic tiles of size (300mm x 600mm) x 7 to 8mm thick as on vertical surfaces such as skirting, dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces with and including over 10mm thick screed bed in ready mix cement based mortar adhesive for fixing tiles complete all as specified and as directed.
26S&F framed work as in doors or gates of angle as in posts and struts, in fencing of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with and including two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
27M&L for machine pressed glossy finished coloured chequered cement concrete tiles of size (30cm x 30cm) x 25mm thick, set and jointed with grey cement slurry and pointed with coloured cement to match over and including 15mm thick screed bed in cement mortar (1:6) over and including 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and as directed.
28M&L for mild steel plain bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooking for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.
29M&L for chain link fencing 4mm dia of galvanised steel wire (100mm x 100mm) mesh made up into mattresses or cages, lapped wire and laid in position including closing after filling etc including binding wire complete all as specified and as directed.
30M&L for 18mm thick granite of black / red colour of any type (table rubbed and polished ) as in wall cladding, pillars, jambs, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note:- The cost of rounding nose and make half round shall be deemed to be included in unit rate.
31M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with ready mix mortar, to be finished even and smooth without using extra cement as whole or patch etc complete all as specified and as directed.
32M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ Ltr and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additive @ 1.43 ltr/10sqm over a coat of exterior primer 0.90 Ltr/ 1p sqm complete all as per manufacturers instructions complete all as specified and as directed.
33S&F stainless steel letters unit Logo written as 1AFSR with stainless steel border height of letter exc 30cm and n exc 45cm and fixed to wall complete all as specified and as directed.
34Supply and fixing oval shape PVC framed, size not exc 1 sqm unit insignia decorative type embossed (unit symbol) on PVC frame as per sample provided by the user complete all as specified and as directed.
35M&L for preparation of new plastered surfaces and applying 3mm thick cement base wall care putty and one coat of alkalic resistent primer and two coats of oil bound distemper complete all as specified and as directed by Engineer-in-Charge.
36M&L for roughening of old concrete / terrazzo floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
37M&L for machine cut Kota stone slab flooring 20-25mm thick, set and jointed with grey cement slurry and pointed with coloured cement to match the shade with and ncluding over of screed bed 15mm thick ready mix cement based mortar adhesive including rubbing/grinding and beeswax polishing etc complete all specified and as directed.
38M&L for machine cut Kota stone slab flooring 20-25mm thick as in riser of steps, skirting, dado etc, set and jointed with grey cement slurry and pointed with coloured cement to match the shade with and ncluding over of screed bed 10mm thick ready mix cement based mortar adhesive including rubbing/grinding and beeswax polishing etc complete all specified and as directed.
39M&L for mild steel black sheet in door 1.6mm thick in steel gate and similar work cut to size, holes punched, including round headed screwed cut nails or riveted and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including or turning up, mitered complete all as specified and as directed.
40M&L for preparation of new or previously untreated surfaces of steel of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
41M&L for reinforced concrete pipes 100mm dia, class NP-2, laid and jointed complete including collars complete all as specified and as directed by Engr-in-Charge.
42S&F 100mm bore cast iron waste and vent pipe in any length with or without ears fixed to walls with pig lead joints fixed to wall including suitable clamps after every one mtr of interval complete all as specified and as directed.
43S&F CI 100mm bends with door complete all as specified and as directed.
44Surface dressing n exc 15cm deep and getting out in soft / loose soil complete all as specified and as directed.
45M&L for reinforced concrete pipes 200mm dia, class NP-2, laid and jointed complete including collars complete all as specified and as directed by Engr-in-Charge.
46M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) complete all as specified and as directed.
47M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed.
48Supply and laying XLPE LT 1100 Volt Grade, armoured under ground cable of size 95 Sqmm 3.5 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
49Description all as per srl item No 48.00 above but 70 Sqmm 3.5 core complele all as specified and as directed.
50Description all as per srl item No 48.00 above but 35 Sqmm 3.5 core complele all as specified and as directed.
51Description all as per srl item No 48.00 above but 25 Sqmm 4 core complele all as specified and as directed.
52M&L for galvanised steel tube, light grade with all fitting complete laid in trenches/ road / Path/ on pole of 80 mm bore complete all as specified and as directed.
53M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 15 Mtrs long including laying HDPE pipe of 150mm dia complete all as specified and as directed.
54Shifting of LT Panel from existing place to another place within range of 400 m with all necessary arrangement and base preparation for LT Panel mounting including PCC foundation with (1:2:4) type B-1 (using 20mm graded stone aggregates) complete all as specified and as directed by Engineer-in-Charge.
55Supply and fixing in replacement of outdoor type cubical Feeder pillar box upto (1000mm x 800mm x 500mm) size suitable for 3 phase, 4 wire, 415V, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof IP 65 class protection and the panel should have upto 1000 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame of size (40mm x 40mm x 5mm) including and front opening type with aprons for cable entry, with double door shutter and locking arrangement etc including fixing with PCC foundation in (1:2:4) type B-1 complete all as specified and as directed by Engineer -in-charge.
56Supply, installation, testing and commissioning of CPRI approved outdoor type LT panel board suitable for 440 Volt, 3 phase & neutral, 50 Hz supply, floor mounted weather and vermin proof fabricated from MS angle of size (50mm x 50mm x 5mm) as base frame, with 3.15mm thick CRCA sheet load bearing members such as door, partitions etc not less than 2.0mm thick, with gland plates at bottom with suitable brass chromium plated glands, with locking arrangements complete, duly powder coated with siemens grey colour after chemical treatment, including LED RYB indicators - 06 nos on incoming side and ON/OFF/ TRIP indications on outgoing side of breaker, interconnections from bus bars to MCCBs with suitable size aluminium bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection, including termianl adaptes, spreader links on incoming and out going sides of MCCBs complete all as specified and as directed and comprising of the following :- (a) Bus bar Aluminium - 600A capacity - 04 Nos high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and outgoing feeders with suitable mounting insulators, heat shrinkable colour sleeves. (b) MCCB 250 Amps 4 pole 36 kA, with adjustable thermal magnetic range as outgoing - 01 No (Main incomer). (c) MCCB 125 Amps 3 pole 16 kA with adjustable thermal magnetic range as outgoing - 04 Nos (d) MCB TP 63 Amps, 10 kA, 'C' Series - 03 Nos (e) MCB SPN 40 Amps, 10 kA 'B' Series - 03 Nos (f) Digital Volt meter - 01 No (g) Digital Amp meter - 01 No (h) ON / OFF indication lamp with toggle switch and three Nos indication lamp (R,Y,B) - 11 Set of three
57M&L for earthing in replacement of with galvanized mild steel earth plate electrode of size (60cm x 60cm) x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip (32x6) mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with fair finished, internal surface of concrete chamber shall be 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80 mm thick RCC pit cover of size 320 mm x 320 mm of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
58S&F post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp and connecting up with three core flexible copper conductor 1.5 sqmm caqble with 40mm dia GI pipe including PCC work complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58469231
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 31.90 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn / Altn To Footpath Interlocking Tiles & Drain In Domestic Area Of Mcc, Addn / Altn To Main Gate Entrance With Improvement To Electrical Infrastructure Of Transformer Of 1 Afsr, Provn Of Kota Stone Tiling Work With Renovation Of Gate At Bldg No. P-19 In Domestic Area Of Mcc, Provn Of Tiles At Certain Places Of Bldg No. P-18 In Domestic Area Of Mcc And Provn Of Interlocking Tiles Path At Airmen Mess In Domestic Area Of Mcc Under Age B/R-Ii At Ge (Af) Palam Delhi Cantt
Basic Detail
Tender No 8026/A/T-74/E8
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 09 Nov 2026
Submission Date 30 Nov 2026
Open Date 07 Dec 2026
Finance
Tender Value 31.90 Lakhs
Tender Fee 500
EMD 63800
Exemption Available
Document List
6a7ca726-2bb1-4b6f-a1d1-1479034994e3.html
BOQ_895167.xls
tender74.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

6a7ca726-2bb1-4b6f-a1d1-1479034994e3.html

xls

BOQ_895167.xls

pdf

tender74.pdf

pdf

Tendernotice_1.pdf

Disclaimer