Tender For Repair/Replacement Of Internal Wiring Alongwith Replacement Of Various Light Fittings, Ceilling Lights And Other Connected Works At Arsenal, Hq Area , B Park Area Of Cafvd Under Age E/M-Ii In Ge (C) Khadki.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
01 Dec 2026
9 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of Internal Wiring Alongwith Replacement Of Various Light Fittings, Ceilling Lights And Other Connected Works At Arsenal, Hq Area , B Park Area Of Cafvd Under Age E/M-Ii In Ge (C) Khadki.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (light, fan socket or power any type) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition seperately) and making good disturbed surface of walls, floors etc complete all as per the existing finish. |
| 2 | Material and labour for point wiring for light/fan/exhaust fan point controlled by one switch in casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and as directed by Engineer in charge. |
| 3 | Description all as per Srl item No 2 above but for point wiring for bell/buzzer point controlled by one bell push. |
| 4 | Description all as per Srl item No 2 above but for point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 5 | Description all as per Srl item No 2 above but for point wiring for 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 6 | Description all as per Srl item No 2 above but for 2.5 sqmm point wiring for 5 pin switch socket outlet 15 Amps on independentboard controlled by one switch. |
| 7 | Material and labourfor point wiring in PVC conduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with plastic laminated sheet cover for one light point or one fan/exhaust fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall and to be done concealed or on surface as directed at site. |
| 8 | Description all as per Srl item No7 above but for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 9 | Description all as per Srl item No 7 above but for 5 pin socket outlet 5 Amps on same board controlled by one switch. |
| 10 | Description all as per Srl item No 7 above but for 2.5 sqmm 5 pin switch socket outlet 15 Amps on independent board controlled by one switch. |
| 11 | Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arragements made out from 20x1mm flat aluminium strip including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with laminated hylum sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, incld material all as specified and as directed. |
| 12 | Description all as per Srl item No 11 above but for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 13 | Description all as per Srl item No 11 above but for 5 pin socket outlet 5 Amps on same board controlled by one switch. |
| 14 | Material and labour for point wiring for one light/ fan/exhaust fan point complete with 1.5 sq.mm single core PVC insulated, unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including DLP mini trunking but shall be increased as per actual site requirement , ISI marked including accessories like bends, tees, junction boxes fixed concealed/ recessed in wall or ceiling including 1.5 sq.mm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including modular metal flush box with white/coloured top cover plate and frame of required modules for mounting of modular switches, sockets,bell push and fan regulators complete and making good to disturbed surfaces all as specified and as directed for following:- |
| 15 | Description all as per Srl item No 14 above but for point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 16 | Description all as per Srl item No 14 above but for point wiring for 5 pin socket outlet 5 Amps on same board controlled by one switch. |
| 17 | Material and labour for point wiring complete as specified with 1100 V grade 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FR grade, conforming to relevant IS drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover including 4 Sqmm single core PVC insulated and unsheathed copper conductor cable FRLSH grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and as directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch. |
| 18 | Description all as per Srl item No 17 above but for for one 3 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in steel conduit. |
| 19 | Description all as per Srl item No 17 above but for for one 3 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit (concealed or on surfcae of wall as directed at site). |
| 20 | Description all as per Srl item No 17 above but for for one 3 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in DLP Mini Trunking. |
| 21 | Supply and fix switch piano flush type single pole, one way 5 Amp all as specified and as directed. |
| 22 | Supply and fix single socket 3 pin , 6A , flush type all as specified and as directed.. |
| 23 | Supplying and fixing 5 Amps, Bell push , flush type , 230 volts AC circuit complete all as specified and as directed |
| 24 | Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal all as specified and as directed. |
| 25 | Supply and fix switch socket combination 2 in 1, 3 pin, 5 & 15 Amp flush type universal all as specified and as directed. |
| 26 | Supplying and fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and as directed . |
| 27 | Supply and fixing in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and as directed. |
| 28 | Supply and fix bell Ding Dong AC, 230 volts, single pole. |
| 29 | Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material all as specified and as directed. |
| 30 | Supply and fix for sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm PVC conduit/Concealed/Steel conduit including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and as directed. |
| 31 | Description all as per Srl item No 30 above but for casing & capping |
| 32 | Supply and fix for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New 20 mm PVC conduit/concealed including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed. |
| 33 | Description all as per Srl item No 32 above but for casing & capping |
| 34 | Supply and fix for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including including New 20 mm PVC conduit/concealed/Steel conduit dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed . |
| 35 | Description all as per Srl item No 34 above but for casing & capping |
| 36 | Supply and fix for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type,10.0 Sqmm, 1100 volts grade, drawn through and including including New 20 mm PVC conduit/Steel conduit connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type,10.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and as directed. |
| 37 | Description all as per Srl item No 36 above but for casing & capping (Note for item No 30 to 37 ) :- (a). Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length. (b) For the above item from 28 to 35 the execution can be carried out upto the height 12 mtr as per requriment and contractor has to ensure the safe execution and the reqd arrangment will be carried by the contractor. |
| 38 | Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and as directed. |
| 39 | Material and labour for sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. |
| 40 | Material and labour for sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. |
| 41 | Material and labour for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and as directed. Note for item No 39 to 41 :- (a). Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length. (b) For the above item from 37 to 39 the execution can be carried out upto the height 12 mtr as per requriment and contractor has to ensure the safe execution and the reqd arrangment will be carried by the contractor. |
| 42 | Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and as directed. |
| 43 | Supply and fix, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 44 | Supply and fix, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 45 | Supply and fix, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule. |
| 46 | Supply and fix, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed |
| 47 | Supply and fix, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed . |
| 48 | Supply and fix, connecting & testing SPN DBs of 4 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified and as directed . |
| 49 | Supply and fix, Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete including taking down all as specified and as directed. |
| 50 | Supply and fix, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete ncluding taking down all as specified and as directed. |
| 51 | Supply and fix, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete ncluding taking down all as specified and as directed. |
| 52 | Supplying & fixing MCB 40 to 63 Amps, TPN \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 53 | Supplying & fixing MCB 40 to 63 Amps, TP \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 54 | Supplying & fixing MCB 6 to 32 Amps, single pole and neutral, \\"C\\" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and as directed. |
| 55 | Supplying & fixing MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and as directed. |
| 56 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and as directed. |
| 57 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 32 Amps and supplied with neutral links complete all as specified and as directed. |
| 58 | Dismantling and Taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed. |
| 59 | Supply & fixing, LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 60 | Supply & fixing, CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 61 | Supply & fixing, LED Inverter Batten suitable for and including 20 W 4 feet long tube with back up time of 3 hrs complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 62 | Supply & fixing, 36W 2X2 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 63 | Supply & fixing, 36W 2X2 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 64 | Supply & fixing, 1X18W,4 Ft LED Ceiling suspended light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 65 | Supply & fixing, 40W, 4 ft LED Recessed mounted LED Luminaire (1 X 4) complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. |
| 66 | Supply & fixing, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. Please Enable Macros to View BoQ information |
| 67 | Supply & fixing, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender