Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58469207

Tender For Special Repair To Pump Sets, Starter Panels, Cables And Improvement To Misc Infrastructutre In Japanese Well No.1 & 2 At Af Stn Carnicobar. 8876/E8

Issued by Statutory Bodies & Commissions/Committees · Nicobars, Andaman And Nicobar Islands
Tender Value
46 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
15 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Pump Sets, Starter Panels, Cables And Improvement To Misc Infrastructutre In Japanese Well No.1 & 2 At Af Stn Carnicobar. 8876/E8

BOQ

Name of Work:- SPECIAL REPAIR TO PUMP SETS, STARTER PANELS, CABLES AND IMPROVEMENT TO MISC INFRASTRUCTUTRE IN JAPANESE WELL NO.1 & 2 AT AF STN CARNICOBAR. 8876/E8
Sl. No. Item Description
1Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
2Dismantling wrought iron or mild steel work of any description not otherwise specifically provided for complete all as specified and as directed.
3Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
4Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
5Removing excavated soil to a distance not exceeding 50 metre away and depositing where as directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed.
6Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed.
7Material and labour for reinforced cement concrete M-30 design mix using 20 mm graded stone aggregate as in as in beams, cantilever, bressummers, lintels over 1.5M span etc complete all as specified and as directed. Note : Reinforcement and form work shall be measured and paid separately.
8Material and labour for reinforced cement concrete M-30 design mix using 20 mm graded stone aggregate as in chajjas etc complete all as specified and as directed. Note : Reinforcement and form work shall be measured and paid separately.
9Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and as directed.
10Use and waste of formwork to sides of pillars, post, struts, piers, coloumn and stanchions, square, rectangular or polygonal, fair finished surfaces of concrete all as specified and as directed.
11Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work, not exceeding 200 mm thick etc, fair finshed surfaces of concrete (Horizontal or sloping) complete all as specified and as directed.
12M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
13M&L for TMT bars 5 mm dia and over upto and including 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips as in stirrups, spacer, and binder complete all as specified and as directed.
14Dismantling of Brick or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified and directed.
15M&L for Pre-cast cement concrete block masonry with solid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed.
16Material and labour for hard core with broken stone or boulders of gauge not exceeding 63 mm, deposited, spread, and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and as directed.
17Material and Labour for 75mm thick Plain Cement Concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed.
18Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 sqm each complete all as specified and as directed.
19Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each complete all as specified and as directed.
20Supply and fix Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with Aluminium alloy wire staples complete all as specified and directed
21Supply and fix in repair 18 mm thick board, finished on both sides with glossy surface acrylic decorative laminate of approved make, shade, colour and design, fixed to box-type cabinets and shutters with suitable screws/fasteners and approved adhesive, including cutting, drilling, fitting, alignment and finishing complete. The exposed vertical thickness/edge surfaces of the cabinets and shutters shall be provided with 2 mm thick glossy-finish acrylic beading/layer of matching colour and shade, neatly fixed and finished to form a uniform and seamless appearance, including all necessary preparation, edge treatment, jointing, making good and incidental works, all as specified and directed by Engineer-in-Charge.
22Providing and fixing heavy-duty stainless steel self-closing hinges, SS 304 grade, conforming to applicable requirements of relevant Indian Standards, with precision-formed/machined hinge leaves and knuckles, corrosion-resistant stainless steel pin and integral adjustable spring/cam mechanism designed to provide positive self-closing action. The hinge shall be suitable for the weight and size of the door/shutter, shall operate smoothly without binding or excessive play, and shall return the door positively to the closed position. Hinge shall be complete with SS 304 grade countersunk fixing screws/fasteners, all accessories, cutting/chasing/drilling where required, fixing, alignment, adjustment and testing, complete in all respects as specified and directed by the Engineer-in-Charge.
23Supply and fix aluminium powder coated (minimum thickness of powder coating 50 micron), frame for doors,windows, ventilators with one or more rebates with joint clip and using rubber beading etc complete all as specified and directed.Note : Glass panel/particle board panel filling shall be measured and paid separately.
24Supply and fix powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, and sliding tower bolt 150mm long anodised aluminium snap beading, screws etc. complete all as specified and as directed.
25Supply and fixing of stainless steel handles, fabricated type, 100 mm size, made from SS 304 grade stainless steel, robustly fabricated with smooth, rounded and burr-free surfaces, properly welded/brazed where applicable, accurately finished and polished/brushed, complete with matching stainless steel mounting plates/roses, SS 304 screws, bolts and other necessary fixing accessories, including drilling, fixing, alignment and making good the surface, complete in all respects as specified and as directed by the Engineer-in-Charge.
26Supply and fix Powder Coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum coating of grade AC 15) of DG 102 design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved aluminium standard section around the opening, all complete as per requirement complete all as specified and directed.
27Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed.
28Material and labour for rendering 10 mm on fair faces of brick or concrete surfaces in CM 1:6, finished even and fair without using extra cement complete all as specified and directed.
29Material and labour for 15 mm thick rendering on brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed.
30Material and labour for preparation of of new plastered/concrete surfaces of walls and applying two coats of acrylic distemper of approved shade/tint over a coat of primer, over 1mm thick wall care putty finish to achieve uniform smooth surface of wall all as specified and as directed.
31Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
32M&L for complete removal by Washing, rubbing down and stopping and preperation of distempered and painted surfaces of walls, pillars,cornices by brooming down etc including filling depressions of scrapped surfaces with wall care putty (1 mm thick) and preparation of surfaces for further treatment and applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed.
33Material and labour for applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surfaces complete all as specified and directed.
34M& L for preparation of naked roof surface by cleaning dust & dirt and applying 15 mm thick rendering in cm(1:3) mixed water proofing compound @ 3% by weight of cement or as per manufactures instructions, finished even and smooth surface all as specified and directed by Engineer in Charge. Note - WPC shall be measured & Paid separately.
35Supply only integral water proofing compound of approved quality all as specified.
36S&F steel work in tubular truss, purlins & columns including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 of grade St-240 complete all as specified and as directed.
37Supply and fix mild steel plate (plain or chequerred), channel, square cut or notched(ordinary or counter sunk) forming holes with riveted, bolted or welded attachment to bottom of pipe conforming to Fe 410-W quality A(Gde-E-250) complete all as specified and directed.
38M&L for MS work as in Wind Tie in roof and MS structural works in trusses, etc with screwed ends including nuts, washers and mild steel plates for walls chimneys, roofs arches etc any kind rods and straining bolts conforming to Fe 410-0 or Fe 310-0 complete all as specified .
39S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified.
40S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified.
41Supply and fix mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm and not exceeding 10 cm of shank 16 to 20mm etc complete all as specified and as directed.
42M&L for preparation of new steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
43Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
44Material and labour for 75mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floors including necessary form work all as specified and as directed.
45Material and labour for machine pressed precast concrete interlocking paver block, any shape and size of 60mm thickness M-35 grade conforming to IS 15658-2006 with grey cement and pigment laid over and including 25mm thick river sand cushioning, compacted with mechanical surface vibrator and with scratch proof lacquer coating on top surfaces complete all as specified and directed.
46Material and labour for providing cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate cast in situ as in kerbs or mud stops, rounded or chamfered on edges, as directed including use of form work as necessary all as specified and as directed.
47Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
48Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
49M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including PVC Casing caping ofheavy gradein the surface of wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, PVC sunken terminal box made out of PVC sheet, PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed for the following :- One light point or one light/fan/ exhaust fan point controlled by one switch
50One 5 pin socket outlet 5 Amps point controlled by one switch on Independent board.
51S&F socket outlet 5 pin, 6 Amps on same board AC 230 volts flush type complete all as specified and directed.
52M&L for point wiring with two single core PVC insulated, unsheathed, FRLS multistranded unsheathed copper conductor cable of size 2.5 sqmm and one single core PVC insulated unsheathed FRLS stranded copper conductor of size 2.5 sqmm green in colour as earth lead through and including PVC casing caping (Heavy grade) with all fittings & accessories ISI marked including provn of PVC sunken boxes of appropriate size & thickness fixed to wall for 15/16 A switch-socket point on independent board complete.
53S&F switch piano flush type AC 230 Volts 6 Amps single pole one way complete all specified and directed
54S&F socket outlet, 3 pin, 6 Amps on same board AC 230 volts flush type complete all as specified and directed.
55Supply & fix switch socket combination,2 in 1, 6 pin, 15/16Amps, multipurpose , flush, shutter type, 230 volt flush type, white/ivory finish with fixing hole complete all as specified and directed by Engineer in charge.
56S & F celing rose surface bakelite 2/3 terminals complete all as specified and directed.
57Supply & fix electronic fan regulator, stepped type, 120 w, 240volts 50Hz, 1/2 Module complete all as specified and as directed.
58Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FRLS) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size rigid non-metallic PVC conduit including taking down old aluminium/Copper Sub main wirng, complete all as specified and directed. Note- 3 run of 4 sq mm PVC copper wire and One run of PVC conduit shall be measured and paid as one unit.
59Supply and fixing in replacement of 20W LED pride essential Batten 6500k,220V, White, Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and as directed. Make-Havells Model No. LHEXAWP7UN1W020 or equivalent in Philips/Bajaj/Crompton.
60Supply and fix in repair of decorative LED Post top Bollard with pole 20 watt, 240 volt with aluminium body pressure die cast powder coated housing with PC diffuser IP-65 protection with inbuilt LED chip and driver, accessories prewired and fixing accessories complete all as specified and directed. Make:Jaquar/ Crompton Greaves/ Havells/Philips.
61M&L for cement concrete type C2 1:3:6 (40mm graded aggregates) in foundation filling and mass concrete .
62M&L for rendering 10mm thick over concrete surface by using cement plaster of ratio 1:4 in floor and walls, finished even and smooth without using extra cement inclduing curing after rendering complete all as specified and as directed.. Please Enable Macros to View BoQ information
63M&L for rendering 10mm thick over concrete surface by using cement plaster of ratio 1:4 in floor and walls, finished even and smooth without using extra cement inclduing curing after rendering complete all as specified and as directed.. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58469207
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Pump Sets, Starter Panels, Cables And Improvement To Misc Infrastructutre In Japanese Well No.1 & 2 At Af Stn Carnicobar. 8876/E8
Basic Detail
Tender No 8876/E8
Bidding Type Tender
Location
City Nicobars
State Andaman And Nicobar Islands
Key Dates
Publish Date 09 Nov 2026
Submission Date 30 Nov 2026
Open Date 07 Dec 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Available
Document List
4daf4e80-2895-4c57-b319-b46cdd790572.html
8876TenderDocu.pdf
8876Testing.pdf
BOQ_895186.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

4daf4e80-2895-4c57-b319-b46cdd790572.html

pdf

8876TenderDocu.pdf

pdf

8876Testing.pdf

xls

BOQ_895186.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender