Drinking Water Supply and Sanitation Local Bodies Closing in 4 days TDR #58468094

Tender For Construction Of Public Toilet @ Ward No:06 In Kalakad Municipality.

Issued by Local Bodies · Tirunelveli, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Nov 2026
4 days left
EMD
7500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Public Toilet @ Ward No:06 In Kalakad Municipality.

BOQ

Name of Work:- Construction of Public Toilet @ Ward No:06 in Kalakad Municipality.
Sl. No. Item Description
1Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
2Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
3Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
4Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
5Random Rubble in Cement Mortar (1:6) etc., Complete complying with standard specification and as directed by the Departmental Officers.
6Providing centering for sides and soffits of R.C.C.works such as lintels, slab that beams plain surface etc., complete excluding strutting upto 3.30 M height using mild steel sheet of size 90 c.m x 60 c.m and 10 gauge stifer with M.S. angles of size 25 mm x 25 mm x 3mm laid over silver w.c.wood joints of size 10 c.m. x 6 c.m. spaced at about 90 c.m. c/c and supported by casurina props of 10 c.m. to 13 c.m. dia spaced 75 c.m. centre to centre complying with as per standard specification.-For Plinth Beam
7For Slab
8Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - For Above floor level
9Supplying and fabricating and placing in position of M.S (or) ribbed Tar steel for all reinforced cement concrete works including cost of steel and binding wire and all labour charges for cutting and fabricaton and other incidental charges etc., complete complying with standard specification.
10Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4” x 4 1/4” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
11Brick partition walls of 10.80cm thickness using best quality Burnt Clay Brick of size 8-3/4” x 4-1/4” x 2-1/4” with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
12Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
13Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
14Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
15Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 and above 20mm thick with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., complete complying with standard speicification and as directed by the departmental officers.(The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)
16Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
17Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
18Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
19Wiring with 2x1.5 sq.mm. PVC insulated unsheathed FRL SSC copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/fan point (for electronic regulator)(5 points per coil),
20Supplying and fixing of 18w LED Tub light fitting approved qulity including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.
21Supply and run of 2 x 1.5 Sq.mm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100 V on 7/20 GI bearer wire for service connection mains etc., complete as per standard specification.
22Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54. Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete.
23Finishing the top of the roof slab with one course of Machine pressed tiles of size 23cm x 23cm x 2 cm of approved quality laid in cementmortar 1:3 ( one cement and three sand) 12mm thick mixed with waterproofing compound 2 % by the weight of cement used and the top pointed with red oxide etc., complete complying with standard specification.
24Providing and fixing PVC. Rainwater Downfall pipes of 110mm diametre with necessary shoes, bends and other speicals, clamps, screws, nails, teakwood plugs etc., complete including cost of all materials. The rate is to include cost of removable cast iron Gratings of appropriate size. The size of teakwood plugs to be used is 150mm * 25mm in front and 200mm * 75mm in rear and all other sides with a depth of 100mm. The pipe is to be fixed by means of \\"U\\" clamps at the cnetre of the pipe screwed to the plugs. The special type of 'U' clamps at the centre of the pipe to be fixed in addition to these for more than three metres pipe length etc., complete cost including cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard specifications.
25Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
26Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level- For 110mm PVC Pipe
27For 75mm PVC Pipe
28Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works)For PVC Elbow 110mm
29For PVC Elbow 75mm
30For PVC TEE 110mm
31For PVC TEE 75mm
32Supply and delivery of PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER 2.50 sqm including all materials and all labour charges etc
33Supply and delivery of HDPE PIPES FOR SUB-MERSIBLE PUMP IN BORE WELL Class-5 (1 MPa or 10 kg./cm2 pressure)32 mm including all materials and all labour charges etc.32mm dia
34Supply and delivery of 32mm pvc pipe including all materials and all labour charges etc
35Supply and delivery of 32mm GI pipe including all materials and all labour charges etc
36Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,1000 Litters
37SD tap
38Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains
39Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1\\"x1/8\\"copper flat)on TW plank of size 375mmx300mmx19mm with supporting TW reepers of 1\\"thick a neither side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20PVC insulated copper wire from EB meter to fuse unit with 1No 40Amp 30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connectiont.
40Supply and fixing of 32A TPNMC switch on suitable angle iron frame work with MS cable entry box with earth connection only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58468094
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 27-11-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Construction Of Public Toilet @ Ward No:06 In Kalakad Municipality.
Basic Detail
Tender No 1992/2026/E1
Bidding Type Tender
Location
City Tirunelveli
State Tamil Nadu
Key Dates
Publish Date 10 Nov 2026
Submission Date 27 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7500
Exemption Not Available
Document List
acb1fb7f-10f2-4b01-89b1-bd75d7e953c0.html
BOQ_869779.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

acb1fb7f-10f2-4b01-89b1-bd75d7e953c0.html

xls

BOQ_869779.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender