Housing Urban and Rular Development Government Departments Closing in 8 days TDR #58467851

Tender For Special Repairs To Leaky Roof In Post Operative Ward Terrace And Doors And Windows In Cmch Ward, Skin Ward, Ms Ward In 500 Bedded Block, Op Block, Blood Bank And Central Lab In Government Medical College Hospital At Thiruvarur In Thiruvaru

Issued by Government Departments · Thiruvarur, Tamil Nadu
Tender Value
10.76 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
8 days left
EMD
10800
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvarur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Leaky Roof In Post Operative Ward Terrace And Doors And Windows In Cmch Ward, Skin Ward, Ms Ward In 500 Bedded Block, Op Block, Blood Bank And Central Lab In Government Medical College Hospital At Thiruvarur In Thiruvarur District.

BOQ

Name of Work:- Special Repairs to leaky roof in Post operative ward terrace and doors and windows in CMCH ward, skin ward, MS ward in 500 bedded block, OP block, blood bank and central lab in Government Medical College Hospital at Thiruvarur in Thiruvarur District.
Sl. No. Item Description
1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls
2Doors & windows including removal of frames, hinges and fastenings
3Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs
4Clean removal of Cement plaster from walls
5Pressed tiles & weathering course
6Clearing Light Jungle
7Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
8Tile joint Re-filling. Cleaning the surface to be freed of dust and fungus with wire brush and cutting the tile joint with \\"U\\" grew, cleaning the joint to be freed of dustwith air blower machine. Apply of bonding agent coating and fillin the \\"U\\" grew with chemical mixed material (SSR Latex, Integrated water proofing liquid and powder, fibre, nice sand and cementmixed material). Apply of tile joint with water proof painting two coats with safe secured coat. Flex coating. Highly performance water proof memberance coating and apply of two coatings to the entire surface including curing etc. complete complying with standard specification and as directed by the departmental officers.
9Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means
10Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. In cement mortar 1:5
11Ground floor
12Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
13Ground floor
14Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
15Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
16Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
17Plain Ceramic Tiles of size 305 x 305 x 6mm
18Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.50mm thick slab
19Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
20Manufacturing, supplying and fixing in position of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed by the departmental officers.
21Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
22Solid panel PVC door with frame
23Supplying , fabricating and fixing in position Aluminium Anodised natural colour matt finish Three track sliding window in all floors with Aluminium sections of Outer Frame bottom [email protected] kg/m,Top & vertical 92.34x29.70x1.50 at 1.066 kg/m, Shutter vertical 39x20x1.50 at 0.493 kg/m,Top & Bottom 18x36.6x1.50 at 0.439 kg/m,Vertical locking arrangement 28.94x39x1.50at0.632 kg/m, the follwing sizes with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete.
24Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
25Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
26SD Tap
27Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.
28CLEAR SIZE 0.60 X 0.60
29CLEAR SIZE 0.90 X 0.90
30Manufacturing supplying and erecting precast RCC Coller of 900mm dia and 50mm thick to a depth of 300 mm including cost of casting, curing, finishing and conveyaence to work site etc complete. (Excluding GST)
31Supplying and fixing position CI Nahani Trap / Floor Trap of size 100 x 75mm with stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
32Cast Iron Nahani Trap of size 100 x 75mm with stainless steel gratings
33Supplying and fixing in position of best approved quality of white glazed European Water closet with P or S trap and with ISI mark The cost is include of double flapped PVC seat cover, PVC pipe 110mm dia and all internal fittings and with necessary CI Brackets 12 mm brass nipple 15mm dia chromium plated broiwn headed stop cock of approved quality with ISI mark and nylon connection including fixing the same to wall and giving necessary water supply connection to the European water closet with 10 lits., capacity porcelin low level flushing Tank with all internal fittings. The European water closet should be fixed on the floor using counter sunk bolts and nuts and necessary teakwood plugs, clamps, screws etc., including dismantling the floor or wall wherever necessary and redoing the same to their original condition etc., complete complying with standard specifications.[The water closet and other materials should be got approved by the Executive Engineer before use on works]
34Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level. Internal Water Supply - Above Ground Level
3525mm dia UPVC pipe
3650 mm dia UPVC pipe
37Supplying and fixing in position UPVC Specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to walls and giving connections to the PVC soil stacks pipes, dismantling the brick masonry or RCC works redoing the dismantled portion to original condition etc.,complete complying with standard specification. and as directed by the departmental officers. (The UPVC specials should be got approved by the Executive Engineer before use on works)
3832mm dia UPVC union
3932mm dia UPVC Tee
4032mm dia UPVC Bend
4132x25mm dia UPVC reducer
4225mm dia UPVC Elbow
4325mm dia UPVC union
4425mm dia UPVC Tee
4525mm dia UPVC Bend
4625x20mm dia UPVC reducer
4720mm dia UPVC union
4820mm dia UPVC Tee
4920mm dia UPVC Bend
5020x15mm dia UPVC reducer
51Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
52110 mm dia PVC soil waste peip
5375mm dia PVC soil waste Pipe
54Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works)
55110mm dia PVC Elbow
56110mm dia PVC Elbow with door
57110mm dia PVC Tee
58110mm dia PVC Tee with Double door
59110mm dia PVC Bend
6075mm dia PVC Elbow
6175mm dia PVC Elbow with door
6275mm dia PVC Tee
6375mm dia PVC Tee with Double door
6475mm dia PVC Bend
65Add GST 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58467851
AUTHORITY Government Departments
TENDER VALUE 10.76 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Special Repairs To Leaky Roof In Post Operative Ward Terrace And Doors And Windows In Cmch Ward, Skin Ward, Ms Ward In 500 Bedded Block, Op Block, Blood Bank And Central Lab In Government Medical College Hospital At Thiruvarur In Thiruvarur District.
Basic Detail
Tender No 8-1/2026-27/JDO/F.6/date 04.11.2026
Bidding Type Tender
Location
City Thiruvarur
State Tamil Nadu
Key Dates
Publish Date 10 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 10.76 Lakhs
Tender Fee Ref. Documents
EMD 10800
Exemption Not Available
Document List
6cea8c96-ae18-4d90-ba08-ad5d4308d529.html
BOQ_868673.xls
Etenderconditionspost.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

6cea8c96-ae18-4d90-ba08-ad5d4308d529.html

xls

BOQ_868673.xls

pdf

Etenderconditionspost.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender