Tender For Construction Of Pack House At Sukinda Seed Farm, Jajpur
Tender Value
18.74 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
2 days left
EMD
18800
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jajapur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Pack House At Sukinda Seed Farm, Jajpur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation of foundation in hard soil within 50m intial lead and 1.5m initial lift including rough dressing and leveling as per direction of Engineer-in-charge. |
| 2 | Filling in foundation and plinth with sand watered and rammed. |
| 3 | Cement concrete (1:4:8) with 4 cm size hard granite metal in foundation and plinth. |
| 4 | Cement Concrete (1:2:4) with 12 mm CBHG chips including hoisting and laying complete |
| 5 | Brick work with Fly Ash Bricks 23 cm x 11cm x 8cm size having crushing strength not less than 75 kg/sq.cm with dimensional tolerance ± 8 percent in cement mortar 1:6 in foundation and plinth |
| 6 | RCC work M-20 grade with 20mm and down grade black hard granite (crusherbroken)stone chips including hoisting and laying including centering and shuttering etc. complete. |
| 7 | (a) Column foundation |
| 8 | (b)Plinth Beam |
| 9 | (c) Lintel |
| 10 | (d)Column & roof beam |
| 11 | Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification. |
| 12 | Brick work with Fly Ash Bricks 23 cm x 11cm x 8cm size having crushing strength not less than 75 kg/sq.cm with dimensional tolerance ± 8 percent in cement mortar (1:6) in Super Structure |
| 13 | 16mm thick cement plaster in C.M(1:6) over brick work inside |
| 14 | 12mm thick cement plaster in C.M(1:6)over brick work out side Plaster |
| 15 | Priming 1 coat with any approved Primer |
| 16 | Distempering two coats to walls of approved shade to give an even shade including cost of distemper etc. |
| 17 | Finishing exterior walls with weather coat of approved shade two coats on new work to give an even shade including cost of paint. |
| 18 | Supplying, fitting & Fixing of vitrified tiles (60cm x 60cm plain/ivory) in floors of approved make confirming to IS : 13755 laid on 20mm thick bed of cement mortar (1:4) & filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-Charge. |
| 19 | Fixing of Vitrified tiles 60cmx60cm (Colour/ Printed) series in dado, skirting and risers of steps on 12mm thick cement plaster in mortar (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of tiles per sqm in Ground floor |
| 20 | Supplying, fitting & fixing of Vitrified Industrial tiles in floors of size (30 x 30) cm of approved make confirming to IS: 4457 laid on 20mm thick CM (1:4) and filling joints with white cement of aproved quality including cost of all materials, labour T & P etc required for the work in Ground Floor |
| 21 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 22 | Supplying, fitting and fixing of M.S. Grill doors/windows/gates, including painting two coats over a coat of primer including cost of transportation making good to the damages of walls and floors etc |
| 23 | Priming one coat with any approved red oxide over iron work |
| 24 | Painting 2coats with any approved iron paint on new iron work. |
| 25 | Filling foundation and plinth with excavated materials. |
| 26 | Iron work wrought and put up in trusses and record racks includind cost of material complete |
| 27 | Hoisting joists and trusses and placing in position cost of square MS cannel for making trusses as per direction of Engineer-in-Charge. |
| 28 | Laying, fitting and fixing of 0.50 mm Pre-Painted Galvanized Roofing Sheet in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. including cost of fitting as per direction of Engineer-incharge. |
| 29 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front modular cover of suitable size , MS modular box with 1.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) |
| 30 | Group-A |
| 31 | Group-B |
| 32 | Supplying and fixing of 5/6 amp one way modular type switch on existing switch box/cover including connections etc as required. |
| 33 | Supplying and fixing of 5 pin 5/6 amp socket outlet modular type on existing switch box/cover including connections etc as required. |
| 34 | Supplying and fixing of 15/16 amp one way modular type switch on existing switch box/cover including connections etc as required. |
| 35 | Supplying and fixing of 6 pin 15/16 amp one way modular socket outlet piano type on existing box/cover including connections etc as required. |
| 36 | Supplying and fixing batten holder/BK angle holder ISI marked including connection etc. as required. |
| 37 | Suppling & fitting of 24W LED bulb with all complete |
| 38 | Installation, testing and commissioning of ceiling fan ( 48\\" decorative), including wiring the down rods of standard length (up to 30 cm) etc. as required. |
| 39 | Installation, testing and commissioning of stepped type modular fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required. |
| 40 | Supplying and fixing of 25 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
| 41 | S/F of 9 watt LED Tube Light (Havels/Phillips/Crompton/Surya) with all complete |
| 42 | Supplyijng and fixing of Triple Pole Neutral 5 amp to 32 amp rating 240 V \\"B\\" miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning |
| 43 | Supply, installation, testing and commissioning of 100 Amp TPN main switches (IS 13940 Part 3/1993) on exisiting surface/wall mounting and complete with HRC fuse links, interconnections, earthing, etc as required as per the direction of Engineer-in-charge. (Make - SEIMENS/HPL/ANCHOR/L&T/ HAVELLS/C&S/RK) |
| 44 | Providing, laying and fixing of one number of PVC insulated and PVC seathed/XLPE power cable (10 sq. mm 4 core PVC armoured cables ISI marked) of 1.1 KV grade of size not exceeding 25 sq. mm on surface as required. |
| 45 | Earthing with copper earth plate 600 mm x 600 mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe, etc. (But without charcoal and salt) as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender