Tender For Construction Of Court Building At Umerkote Buildings.
Tender Value
9.23 Crore
Estimated cost
Bid Submission
23 Nov 2026
0 days left
EMD
9.23 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Court Building At Umerkote Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKSLoosening levelling & compacting original ground suppourting embankment to facilitate a placement of 1st layer of embankment up to a depth of 150mm mixed with water at OMC & then and then compacted by rolling as per Clause 300.20 for embankment construction as per Clause No- 305.3.4 of MoRTH specifiction. (Approach Road) |
| 2 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
| 3 | Construction of granular sub-base by providing Grading-VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 (Approach Road) |
| 4 | Supplying and filling in foundation trenches and plinth with sand, well watered and rammed in layers not exceeding 23cm in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and , materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer-in-Charge. |
| 5 | Providing and lying Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (1 1/2\\") 0 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading,cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 6 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-20 grade as per approved designs and drawings having a minimum compressive strength (in work test) 200 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position complete as per direction of Engineer-In -Charge.RCC Drain with coverslab |
| 7 | Column Base Footing-Security Room & Compound Wall |
| 8 | Plinth beam-Security Room & Compound Wall |
| 9 | Column -Security Room & Compound Wall |
| 10 | Lintel-Security Room |
| 11 | Chajja-Security Room |
| 12 | Roof beam-Security Room & Compound Wall |
| 13 | Roof Slab-Security Room |
| 14 | Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.Approach Road |
| 15 | Supplying and fixing of 80 mm thick cement concrete interlocking paver block of M-40 grade of approved make , design, colour and size made by block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 And as directed by theEngineer-In-Charge.Approach Road |
| 16 | Filling foundation and plinth with excavated materials including watering and ramming complete in all respect as directed by the Engineer-in-Charge |
| 17 | Carriage of earth by mechanical means with cost of all lead & lift upto 5 km including cost of all labour, T&P etc., comp. as per specification & direction of Engineer-in-chargeGround Floor |
| 18 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position complete as per direction of Engineer-In -Charge.Column Base FootingGround Floor |
| 19 | Plinth beam-Ground Floor |
| 20 | Column-Ground Floor |
| 21 | First Floor |
| 22 | Head Room |
| 23 | Lintel-Ground Floor |
| 24 | First Floor |
| 25 | Head Room |
| 26 | Chajja-Ground Floor |
| 27 | First Floor |
| 28 | Head Room |
| 29 | Staircase-Ground Floor |
| 30 | First Floor |
| 31 | Roof beam-Ground Floor |
| 32 | First Floor |
| 33 | Head Room |
| 34 | Roof Slab-Ground Floor |
| 35 | First Floor |
| 36 | Head Room |
| 37 | Supplying, Cutting, Straightening coiled or bent up M.S. rods or Tor steel of SAIL(HYSD Fe-500,550) welding or jointing if necessary, bending, binding, tying the grills and laying in position as required for R.C.C. works and hoisting, lowering and placing in position in all floors according to approved designs and drawings including cost, conveyance, of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P etc. complete in all respect as directed by the Engineer-in-charge All reinforcement steel and structural steel shall be procured from primary producers of steel-SAIL/RINL/TATA/JINDAL(Panther)/SHYAM STEEL.Ground Floor,Security,Drain,Compound Wall |
| 38 | First Floor |
| 39 | Head Room |
| 40 | Brickwork with Fly ash bricks in cement mortar (1:6) in F&P (23cm x 11cm x 8 cm) having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections watering and curing for 7 days after immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work and royalties etc. complete in all respect as per direction of Engineer in charge. |
| 41 | Brickwork with Fly ash bricks in cement mortar (1:6) in Superstructure (23cm x 11cm x 8 cm) having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections watering and curing for 7 days after immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work and royalties etc. complete in all respect as per direction of Engineer in charge.Ground Floor,Security,Compound Wall |
| 42 | First Floor |
| 43 | Head Room |
| 44 | Brickwork with Fly ash bricks in cement mortar (1:4) in Superstructure (23cm x 11cm x 8 cm) having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections watering and curing for 7 days after immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work and royalties etc. complete in all respect as per direction of Engineer in charge.Ground Floor |
| 45 | First Floor |
| 46 | 6mm thick cement plaster (1:4) finished smooth to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment including watering, curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with royalities etc. complete in all respect as per direction of Engineer in charge.Ground Floor,Security, |
| 47 | First Floor |
| 48 | Head Room |
| 49 | 12mm (1/2'') thick cement plaster in cement mortar (1:6) finished smooth to brick walls after raking out the joint including watering and curing for seven days with cost and conveyance of all materials and labour with T& P required for the work and royalities etc. complete in all respect as per direction of Engineer in charge.Ground Floor,Security,Compound Wall |
| 50 | First Floor |
| 51 | Head Room |
| 52 | 16mm (5/8'') thick cement plaster (1:6) finished smooth to inside of 9''/10'' thick brick walls after raking out the joint including watering, curing for seven days with cost and conveyance of all materials and labour with T&P required for the work and royalities etc. complete in all respect as per direction of Engineer in charge.Ground Floor,Security,Compound Wall |
| 53 | First Floor |
| 54 | Head Room |
| 55 | 12mm (1/2'') thick cement plaster in cement mortar (1:4) finished smooth to brick walls after raking out the joint including watering and curing for seven days with cost and conveyance of all materials and labour with T& P required for the work and royalities etc. complete in all respect as per direction of Engineer in charge.Ground Floor |
| 56 | First Floor |
| 57 | Supplying, fitting and fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 15622-2006 (Group-B) of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, taxes, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.Ground Floor,Security |
| 58 | First Floor |
| 59 | Providing and fixing of homogeneous vitrified tiles in dados, skirting and rises of steps /walls on/over 12mm th cement plaster (1:3) (1cement:3sand) joined with neat cement slurry mixed with pigment to match the shade of tiles, rubbing, polishing including cost of tiles, conveyance, taxes & labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge |
| 60 | First Floor |
| 61 | Supplying, fitting and fixing Granaite tile in floors of approved make conformaing to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C. Ground Floor |
| 62 | First Floor |
| 63 | Supplying, fitting and fixing vitrified industrial floor tile 30x30cm premium grade 8 to 10 mm thick in floors of approved make confirming to IS : 4457 laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. as per direction of the Engineer-in-Charge. |
| 64 | Supplying fitting, fixing of 125 mm x65mm ( after moulding ) well blend beautiful WPC ( Wood plastic composite choukath in door opening area tha wall surface of WPC Chaukaths 150mm anchor fastner screw cutting the holes filling the cutting holes in cement concrete (1:2:4) etc all complete in all respect and as per direction of Engineer-in-charge. |
| 65 | Providing and fixing ISI marked 32 mm thick flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of Ist class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete as per the direction of Engineer-In-Charge. |
| 66 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.) Casement Door 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding the door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. |
| 67 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD.) Three Track - Three Panel sliding window 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards |
| 68 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) ( FENESTA / NCL VEKA LTD.) Ventilator/ Top Hung 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 75 mm x 60 mm x 2.25 mm for casement Window Sash Profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.- |
| 69 | Supplying, fitting, fixing of, M.S Grill for (MS Door, MS GATE ,M.S grill ,, MS Square Bar Spike to openings,tubular trusses and collapsible gate ) of approved specification and of approved size, materials and design with a coat of primer including painting two coats over a coat of redoxide primer with cost and conveyance of all materials, labour, royality, etc. complete in all respect and as per direction of Engineer-in-charge. |
| 70 | Supplying, fitting and fixing of false ceiling of size 600mm x 600mm of approved qualiy including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge. |
| 71 | Supplying, fitting, fixing of Stainless steel of 304 Grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmX32mmX2mm @ 0.90mt.c/c & stainless square pipe bracing of size 32mmX32mmX2mm in 3 rows in stair case as per approved design & specification, buffing, polishing etc with cost,conveyance,, labour,T&P etc. required for the work complete in all respect in all floors as per direction of Engineer-in-Charge. |
| 72 | Painting two coats of Synthetic enamel paint to Iron/Wood work over a coat of primer with cost, conveyance, taxes of all materials and labour with T&P required for the work etc.complete in all respect as per direction of Engineer in charge.Ground Floor,Security,Compound Wall |
| 73 | First Floor |
| 74 | Head Room |
| 75 | Finishing wall surface of wall with wall putty (Water based) of approved make and finished smooth and even surface to receive paiting including cost of scaffulding stsging changes with cost of all materials labour etc complete in all respect as per direction of Engineer In Charge. Ground Floor |
| 76 | First Floor |
| 77 | Head Room |
| 78 | Finishing wall surface with Weather Coat two coats with any approved shade over a coat of primer including cost, conveyance, , cess and royalties of all materials with labour and T&P required for the work etc., complete in all respect as per direction of Engineer In Charge. Ground Floor,Security,Compound Wall |
| 79 | First Floor |
| 80 | Head Room |
| 81 | Painting 2(Two) coats with any approved Plastic Emulsion paint to wall surface after cleaning the surface including cost of P.E Paint Cost,Coneyance, of all materials and labour with T&P required for the work etc. comple te in all floors complete in all respects as per the direction of engineer incharge.Ground Floor,Security,Compound Wall |
| 82 | First Floor |
| 83 | Head Room |
| 84 | Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. |
| 85 | 2.5 cm.(1'') thick grading concrete(1:2:2) over roof slab after chipping and cleaning the surfaces by wire brushing, laid to proper slope finished smooth including watering, curing, cost, conveyance of all materials such as 6mm size black hard granite crusher broken chips, sand, cement etc. and labour with T& P required for the work with all taxes and royalities etc. complete in all respect as per direction of Engineer in charge. First Floor |
| 86 | Head Room |
| 87 | Providing and fixing rain water down pipe with necessary bend shoes and heads including cost of 110mm dia earthen pipe, clamps and nails etc. with all cost, conveyance, taxes of all the materials required for the work with all labour, T&P and cess etc. complete in all respect as per specification and direction of the Engineer-in-charge |
| 88 | Construction of embankment with approved material obtained from borrow pits with all lifts and 10km lead, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. |
| 89 | Excavation of foundation for structure in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transpor |
| 90 | Furnishing and laying of the live suds of perrinial turf grass on embankment slope within 5km average lead by mechanical means and 1.5m initial lift |
| 91 | EI WORKSSub-Head I (modular Wiring Items)Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A |
| 92 | GROUP-B |
| 93 | GROUP-C |
| 94 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 95 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 96 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 97 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 98 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 01 no of 2 nos 6A switch & socket(modular type) ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 99 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit(2X1.5+1X1.5) |
| 100 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5) |
| 101 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit . (2X4+1X1.5) |
| 102 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X4+2X2.5)(UPS BDB) |
| 103 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit. (4X6+2X4) |
| 104 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit . (4X10+2X6) |
| 105 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 106 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 107 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 108 | Sub-Head II (Light fitting Fixture & Fan)Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 109 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 110 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery greater than equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) |
| 111 | SITC of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 112 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years. |
| 113 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 114 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 115 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 116 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 117 | Supplying an fixing of wall up/down column LED 24W pressure die cast iron aluminium high transmitive PMMA diffuser having exterior wall glazing with power consuption max. up to 24w ,system lumens output 3000 lumens LED chip life 50000 burning hours at L70 maximut tested for 10k hours for complayance of TM21 Projection.The LED used shall be CCT of 5700K.Luminaire should be isolated & mulitstage constant current APFC type. The driver should be BIS Registered with input voltage range of 150v to 270v(normal rated voltage-240v)with max. 2 kv surge protection PF>0.95,THD <15%,IP 20 (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 118 | BDBS,DB,AC DB,FLOOR PANELS,MCBSSupplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,Computer DB)(FOR LIGHT,UPS DB,PDB) |
| 119 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR ups Outgoing DB)Warranty on DB is 3 years |
| 120 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 121 | Supplying and fixing 40Amps 4P 415 volts, MCB,C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 122 | Supplying and fixing 40 Amps rating,4P 415V, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 123 | Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years. |
| 124 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 125 | Supplying and fixing 16Amps 4P 415 volts, MCB,C series, 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 126 | Supplying and fixing 16 Amps rating,4P 415V, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 127 | (Earthing) INSTALLATIONSupplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 128 | Supplying,installation,testing & commissioning of materials and installation ofcopper earth plate 600mmx600mmx3.18mm thick ISI marked with copper nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 129 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 130 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 131 | CABLING AND END TERMINATION MAIN AREASupplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 150 sq mm |
| 132 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 16 sq mm |
| 133 | LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 134 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 135 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 136 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x150 sq mm |
| 137 | 4 core x16 sq mm |
| 138 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
| 139 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia |
| 140 | PANELS MAIN CONTROL PANEL AT GF S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.40X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.All the outgoing MCCB feeders shall have provision of digital ammeter with class 1 CT of suitable capacity. Mandatory provision of cable alley is to be given. In commer-1-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula(FROM TRANSFORMER)In commer-2-01 number of 320A4P Icu=100%Ics,36kA LSIG MCCB with micro processor based release( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula) (DG INCOMMER)In commer-2- 01 no of 400A 4P onload changeover switch ( DG 01 NO)(Make-ABB/Siemens/Schneider/Legrand)Busbar-1&2 04 numbers of 500Amps aluminum busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- 01 numbers of 320A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA) (For DG AMF)Out going- 01 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA)Out going- 05 numbers of 63A 4P MCCB,16Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULLA)Out going- 8 numbers of 40A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) Out going- 8 numbers of 63A rating,10 KA breaking capacity,C series, 4P MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication for incomerAll the MCCB outgoing feeders shall havedigital ammeter with suitable rating class 1 CT as per the feeders rating. Make-LEGRAND/ Siemens/ Schneider/ABB) 2 no. 50 kA/pole 3P+N type 1+2 SPD with 600A HRC backup fuse. Make of SPD -ABB/OBO/Dehn |
| 141 | UPS SYSTEMSupply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD OF EM) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD. |
| 142 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWERSupplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 143 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 144 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 145 | Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. |
| 146 | Supplying,fixing of 8 module under- FLOOR outlet box IP20, size not less than 308mmx308mm as required as per direction of Engg.-in-Charge.MAKE- Profab/OBO/Neidax/Legrand |
| 147 | ELV Subhead- 1 (Lan System)SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance less than equal to 9.38 ohm/100m Max., Cable support Delay Skew: less than 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 ohm @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 148 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 micrometer. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 149 | SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit |
| 150 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 microinch Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length) |
| 151 | SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50 microinch Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(2 mtr length) |
| 152 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 153 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 inch ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 154 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit |
| 155 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 156 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP,Netgear |
| 157 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 158 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 159 | Supplying and fixing of following sizes of heavy class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak 20 MM |
| 160 | 25 MM |
| 161 | SITC of Gate way Router with Built-in firewall provides anti-virus, layer 3-7 IDS/IPS, DPI, SSL detection, and more. Built-in VPN router supports 2.5Gbps or 3Gbps to allow easy remote access. 2 x 2.5 Gigabit SFP port and 10 x Gigabit Ethernet ports *3x Fixed WAN. 2.5Gbps Router. 4 x PoE out ports, IEEE802.3af/at, Maximum PoE Wattage: 36W. Make: Grandstream, Ruijie, HP |
| 162 | Subhead- 1.a (IP-PBX System)Supplying and fixing of Hybrid EPABX system equipped with 128 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Make-Matrix/Siemens/Coral |
| 163 | Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel |
| 164 | S/f of 50 pair MDF box with 3 nos. krone module. |
| 165 | S/f of 5O pair krone box with 2 no. krone module |
| 166 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 167 | 20 Pair |
| 168 | Subhead- 3 (IP-CCTV System)SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch |
| 169 | Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Dome/Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, four stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux (color), 0 Lux IR On, 3 IR LEDs, Smart IR with upto 70m(bullet)/50m(dome) IR distance, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000; Adavance Video Compression technology such as H.265 HEVC/ H.264 / MJPEG , Fixed Lens 2.7-13.5mm motorized, Field of View FoV H:100-28.5°, V:73-21.4°, BLC, HLC, WDR, 2D/3DNR, White Balance - Auto/Manual/Day/Night/timing, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 5 Privacy Mask, 6 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2TB SD card support, PoE (802.3 af) and 12V DC, IP 66/67 & IK10 Vandal proof with Die Cast Aluminium Housing, Having Operating temp range : 30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000),NDA,STQC compliant. Make-Honeywell value series/Pelco/Axis/Bosch |
| 170 | SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch |
| 171 | Supply & Installation 10 TB Surveillence Hardisk.Make: Seagate/WD/Toshiba |
| 172 | SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony |
| 173 | SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer |
| 174 | PA SYSTEMSupplying, installing, testing and commissioning of Power mixture amplifier of 480 watt.The amplifier should be clean reliable audio for public address amplification.Line input less than 1 volt, unbalanced& line output less than 1 volt unbalanced.Make-Honeywell/Bose/Bosch. |
| 175 | Supplying, installation, testing & commissioning of 6 zone voice alarm controller with USB MP3 am/fm included 6 zone button paging station and microphoneMake. Honeywell/Bose/Bosch/JBL |
| 176 | Supplying, installing, testing and commissioning of 12 Watt wall mounted speaker completed as required.Make-Honeywell/Bose/Bosch. Please Enable Macros to View BoQ information |
| 177 | Supplying, installing, testing and commissioning of 12 Watt wall mounted speaker completed as required.Make-Honeywell/Bose/Bosch. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender