Tender For Development Of Thematic Display Area Australian Adventure With Four Nos. Of Enclosures And Landscaping Inside Nandankanan Zoological Park.
Tender Value
5.03 Crore
Estimated cost
Bid Submission
23 Nov 2026
2 days left
EMD
5.04 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Development Of Thematic Display Area Australian Adventure With Four Nos. Of Enclosures And Landscaping Inside Nandankanan Zoological Park.
BOQ
| Sl. No. | Item Description |
| 1 | 2 NOS OF STRUCTURE FOR WALLABY BACK KRAAL, |
| 2 | EARTH WORK |
| 3 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 4 | Ordinary Soil |
| 5 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 6 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 7 | Supplying , diluting and and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc. complete.as per IS:6313/1981 (PART-II) and as per the direction of engineer-in-charge including all cost of materials labour, taxes etc. all complete. |
| 8 | PLAIN & REINFORCEMENT CONCRETE |
| 9 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 10 | M-25 Grade Concrete with Centring & shuttering |
| 11 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 12 | For R.C.C plinth band etc. |
| 13 | R.C.C Beam & Coloum(Ground Floor) |
| 14 | Lintel & Sill (Ground Floor) |
| 15 | Roof slab,Landing,Balcony, (Ground Floor) |
| 16 | Cutting ,Straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary , bending ,tying the grills as required for R.C.C works etcwinding wire extra |
| 17 | Foundation |
| 18 | Ground floor |
| 19 | BRICK WORK |
| 20 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 21 | Foundation and Plinth |
| 22 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 23 | Ground Floor |
| 24 | 1st Floor |
| 25 | PLASTERING & PAINTING |
| 26 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 27 | Ground floor |
| 28 | Terrace |
| 29 | Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge. (Ground floor) |
| 30 | Finishing wall surface of wall with cement based wall putty [water based] of approved make and finished smooth and even surface to receive painting including cost etc |
| 31 | Ground Floor |
| 32 | Terrace |
| 33 | Providing and applying 2 coats with 100% acrylic emulsion paint on New surface including one coat of primer (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. |
| 34 | Ground floor |
| 35 | First floor |
| 36 | Supplying and painting of internal walls and ceiling with two or more coats of ACRYLIC emulsion paint on New surface which includes a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge. (Ground floor) |
| 37 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete. (Ground floor) |
| 38 | FLOORING |
| 39 | Fixing Kota stone (over 0.10 Sqms) in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1cement : 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of kota stone. (Ground floor) |
| 40 | Fixing Kota stone (ABOVE 0.10 Sqms) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including all costs complete (Ground floor) |
| 41 | Grading plaster |
| 42 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips |
| 43 | STEEL WORK |
| 44 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction bolt welded tubes etc. complete as directed by the Engineer-in-Charge. |
| 45 | Supplying and fixing of G.I. chain link mesh (TATA) of size ( 2\\" x 2\\" x 10 Gauge) to cover the Back kraal area including all cost conveyance of materials and labour with labour cess royalty, transportation loading & unloading , cost , T&P etc. required for the work all complete in all respect as per direction of the Engineer in charge . |
| 46 | Providing and fixing UV-stabilized transparent multiwall/solid polycarbonate roofing sheet of approved make (e.g., Lexan, Danpal, Palram, Gallina or equivalent), of approved thickness (6mm or as specified), fixed over steel purlins/trusses with aluminium profiles or polycarbonate connectors, EPDM rubber gaskets, aluminium end closures, self-drilling stainless steel screws with EPDM washers, approved sealant and all necessary accessories, including cutting, drilling, sealing, overlapping, finishing, complete in all respects as per manufacturer’s specifications and direction of the Engineer-in-Charge. The rate includes all labour, materials, scaffolding, transportation, wastage and incidental charges but excludes the structural steel supporting framework, which shall be measured and paid separately. |
| 47 | Supplying fitting and fixing of stainless steel of 304 grade in Steel grating using cross (20 x 20)mm of 2mm thick square pipe and stainless square pipe of size 32mm x 32mm x 2mm in grate frame as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect . |
| 48 | EMU BACK KRAAL |
| 49 | EARTH WORK |
| 50 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 51 | Ordinary Soil |
| 52 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 53 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 54 | Making plinth protection 150 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth |
| 55 | Supplying , diluting and and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc. complete.as per IS:6313/1981 (PART-II) and as per the direction of engineer-in-charge including all cost of materials labour, taxes etc. all complete. |
| 56 | Providing and laying of P.C.C. of 1:4:8 with 4 c.m size hard granite metal in foundation trenches, under floors in line level including curing and ramming etc. all complete as per the direction of the Engineer-in-charge.. |
| 57 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc including Rigid & smooth centering and shuttering. |
| 58 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 59 | For R.C.C plinth band etc. |
| 60 | R.C.C Beam & Coloum |
| 61 | Ground Floor |
| 62 | First Floor |
| 63 | Lintel & Sill(Ground Floor) |
| 64 | Roof slab,Landing,Balcony,(Ground Floor) |
| 65 | Cutting ,Straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary , bending ,tying the grills as required for R.C.C works etcwinding wire extra |
| 66 | Foundation |
| 67 | Ground floor |
| 68 | Terrace |
| 69 | BRICK WORK |
| 70 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 71 | Foundation and Plinth |
| 72 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 73 | Ground Floor |
| 74 | 1st Floor |
| 75 | PLASTERING & PAINTING |
| 76 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 77 | Ground floor |
| 78 | Terrace |
| 79 | Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge.(Ground floor) |
| 80 | Finishing wall surface of wall with cement based wall putty [water based] of approved make and finished smooth and even surface to receive painting including cost etc |
| 81 | Ground Floor |
| 82 | Terrace |
| 83 | Providing and applying 2 coats with 100% acrylic emulsion paint on New surface including one coat of primer (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. |
| 84 | Ground floor |
| 85 | First floor |
| 86 | Supplying and painting of internal walls and ceiling with two or more coats of ACRYLIC emulsion paint on New surface which includes a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge.(Ground floor) |
| 87 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete. (Ground floor) |
| 88 | FLOORING |
| 89 | Fixing Kota stone (over 0.10 Sqms) in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1cement : 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of kota stone.(Ground floor) |
| 90 | Fixing Kota stone (ABOVE 0.10 Sqms) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including all costs complete (Ground floor) |
| 91 | Grading plaster |
| 92 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips |
| 93 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction bolt welded tubes etc. complete as directed by the Engineer-in-Charge. |
| 94 | Supplying and fixing of G.I. chain link mesh (TATA) of size ( 2\\" x 2\\" x 10 Gauge) to cover the Back kraal area including all cost conveyance of materials and labour with labour cess royalty, transportation loading & unloading , cost , T&P etc. required for the work all complete in all respect as per direction of the Engineer in charge . |
| 95 | Supplying fitting and fixing of stainless steel of 304 grade in Steel grating using cross (20 x 20)mm of 2mm thick square pipe and stainless square pipe of size 32mm x 32mm x 2mm in grate frame as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect . |
| 96 | 2 NOS OF STRUCTURE FOR CASSOWARY BACK KRAAL, |
| 97 | EARTH WORK |
| 98 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 99 | Ordinary Soil |
| 100 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 101 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 102 | Supplying , diluting and and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc. complete.as per IS:6313/1981 (PART-II) and as per the direction of engineer-in-charge including all cost of materials labour, taxes etc. all complete. |
| 103 | PLAIN & REINFORCEMENT CONCRETE |
| 104 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 105 | M-25 Grade Concrete with Centring & shuttering |
| 106 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 107 | For R.C.C plinth band etc. |
| 108 | R.C.C Beam & Coloum(Ground Floor) |
| 109 | Lintel & Sill (Ground Floor) |
| 110 | Roof slab,Landing,Balcony, (Ground Floor) |
| 111 | Cutting ,Straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary , bending ,tying the grills as required for R.C.C works etcwinding wire extra |
| 112 | Foundation |
| 113 | Ground floor |
| 114 | BRICK WORK |
| 115 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 116 | Foundation and Plinth |
| 117 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 118 | Ground Floor |
| 119 | 1st Floor |
| 120 | PLASTERING & PAINTING |
| 121 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 122 | Ground floor |
| 123 | Terrace |
| 124 | Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge. (Ground floor) |
| 125 | Finishing wall surface of wall with cement based wall putty [water based] of approved make and finished smooth and even surface to receive painting including cost etc |
| 126 | Ground Floor |
| 127 | Terrace |
| 128 | Providing and applying 2 coats with 100% acrylic emulsion paint on New surface including one coat of primer (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. |
| 129 | Ground floor |
| 130 | First floor |
| 131 | Supplying and painting of internal walls and ceiling with two or more coats of ACRYLIC emulsion paint on New surface which includes a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge(.Ground floor) |
| 132 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete. (Ground floor) |
| 133 | FLOORING |
| 134 | Fixing Kota stone (over 0.10 Sqms) in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1cement : 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of kota stone. (Ground floor) |
| 135 | Fixing Kota stone (ABOVE 0.10 Sqms) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including all costs complete (Ground floor) |
| 136 | Grading plaster |
| 137 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips |
| 138 | STEEL WORK |
| 139 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction bolt welded tubes etc. complete as directed by the Engineer-in-Charge. |
| 140 | Supplying and fixing of G.I. chain link mesh (TATA) of size ( 2\\" x 2\\" x 10 Gauge) to cover the Back kraal area including all cost conveyance of materials and labour with labour cess royalty, transportation loading & unloading , cost , T&P etc. required for the work all complete in all respect as per direction of the Engineer in charge . |
| 141 | Providing and fixing UV-stabilized transparent multiwall/solid polycarbonate roofing sheet of approved make (e.g., Lexan, Danpal, Palram, Gallina or equivalent), of approved thickness (6mm or as specified), fixed over steel purlins/trusses with aluminium profiles or polycarbonate connectors, EPDM rubber gaskets, aluminium end closures, self-drilling stainless steel screws with EPDM washers, approved sealant and all necessary accessories, including cutting, drilling, sealing, overlapping, finishing, complete in all respects as per manufacturer’s specifications and direction of the Engineer-in-Charge. The rate includes all labour, materials, scaffolding, transportation, wastage and incidental charges but excludes the structural steel supporting framework, which shall be measured and paid separately. |
| 142 | Supplying fitting and fixing of stainless steel of 304 grade in Steel grating using cross (20 x 20)mm of 2mm thick square pipe and stainless square pipe of size 32mm x 32mm x 2mm in grate frame as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect . |
| 143 | 2 NOS OF STRUCTURE FOR KANGAROO BACK KRAAL, |
| 144 | EARTH WORK |
| 145 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 146 | Ordinary Soil |
| 147 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 148 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 149 | Supplying , diluting and and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres ( or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc. complete.as per IS:6313/1981 (PART-II) and as per the direction of engineer-in-charge including all cost of materials labour, taxes etc. all complete. |
| 150 | PLAIN & REINFORCEMENT CONCRETE |
| 151 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 152 | M-25 Grade Concrete with Centring & shuttering |
| 153 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 154 | For R.C.C plinth band etc. |
| 155 | R.C.C Beam & Coloum(Ground Floor) |
| 156 | Lintel & Sill (Ground Floor) |
| 157 | Roof slab,Landing,Balcony, (Ground Floor) |
| 158 | Cutting ,Straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary , bending ,tying the grills as required for R.C.C works etcwinding wire extra |
| 159 | Foundation |
| 160 | Ground floor |
| 161 | BRICK WORK |
| 162 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 163 | Foundation and Plinth |
| 164 | Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 11 c.m x 8 c.m in superstructure having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 165 | Ground Floor |
| 166 | 1st Floor |
| 167 | PLASTERING & PAINTING |
| 168 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 169 | Ground floor |
| 170 | Terrace |
| 171 | Providing average 6 mm thick cement plaster(1:4) to R.C.C surfaces finished smooth including deep chipping & slurring treatment etc. complete.as per the direction of the Engineer-in-charge.(Ground floor) |
| 172 | Finishing wall surface of wall with cement based wall putty [water based] of approved make and finished smooth and even surface to receive painting including cost etc |
| 173 | Ground Floor |
| 174 | Terrace |
| 175 | Providing and applying 2 coats with 100% acrylic emulsion paint on New surface including one coat of primer (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. |
| 176 | Ground floor |
| 177 | First floor |
| 178 | Supplying and painting of internal walls and ceiling with two or more coats of ACRYLIC emulsion paint on New surface which includes a coat of primer all complete. The shade and brand to be of approved brand & shade over the surfaces including preparation of surface, with cost of all materials, labour, conveyance taxes of all materials,scaffolding etc., as per the direction of the Engineer-in-charge.(Ground floor) |
| 179 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.(Ground floor) |
| 180 | FLOORING |
| 181 | Fixing Kota stone (over 0.10 Sqms) in floors treads or steps and landing on 20 mm thick bed of cement mortar 1:4 (1cement : 4 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of kota stone. (Ground floor) |
| 182 | Fixing Kota stone (ABOVE 0.10 Sqms) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete including all costs complete (Ground floor) |
| 183 | Grading plaster |
| 184 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips |
| 185 | STEEL WORK |
| 186 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction bolt welded tubes etc. complete as directed by the Engineer-in-Charge. |
| 187 | Supplying and fixing of G.I. chain link mesh (TATA) of size ( 2\\" x 2\\" x 10 Gauge) to cover the Back kraal area including all cost conveyance of materials and labour with labour cess royalty, transportation loading & unloading , cost , T&P etc. required for the work all complete in all respect as per direction of the Engineer in charge . |
| 188 | Providing and fixing UV-stabilized transparent multiwall/solid polycarbonate roofing sheet of approved make (e.g., Lexan, Danpal, Palram, Gallina or equivalent), of approved thickness (6mm or as specified), fixed over steel purlins/trusses with aluminium profiles or polycarbonate connectors, EPDM rubber gaskets, aluminium end closures, self-drilling stainless steel screws with EPDM washers, approved sealant and all necessary accessories, including cutting, drilling, sealing, overlapping, finishing, complete in all respects as per manufacturer’s specifications and direction of the Engineer-in-Charge. The rate includes all labour, materials, scaffolding, transportation, wastage and incidental charges but excludes the structural steel supporting framework, which shall be measured and paid separately. |
| 189 | Supplying fitting and fixing of stainless steel of 304 grade in Steel grating using cross (20 x 20)mm of 2mm thick square pipe and stainless square pipe of size 32mm x 32mm x 2mm in grate frame as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour and T&P required for the work all complete in all respect . |
| 190 | RETAINING WALL ENCLOSER DEVELOPMENT |
| 191 | EARTH WORK |
| 192 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 193 | Ordinary Soil |
| 194 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 195 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 196 | PLAIN & REINFORCEMENT CONCRETE |
| 197 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 198 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc including Rigid & smooth centering and shuttering. |
| 199 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 200 | Retaining Wall Stem |
| 201 | Cutting ,Straightening coiled or bend up HYSD/TMT Reinforcement bars welding or jointing if necessary , bending ,tying the grills as required for R.C.C works etcwinding wire extra |
| 202 | Retaining Wall Raft |
| 203 | Retaining Wall Stem |
| 204 | PLASTERING & PAINTING |
| 205 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. (Ground Floor) |
| 206 | Providing and applying 2 coats with 100% acrylic emulsion paint on New surface including one coat of primer (exterior quality) of approved make & shade by reputed manufacturer to make an even finished surface over a coat of primer with water bound cement primer in all heights with all scaffolding and staging charges including cost , conveyance, taxes of all materials, cost of all labours , T & P, sundries etc. as required for the work complete. (Ground Floor) |
| 207 | Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC / PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face and as per drawing and technical specification including cost, conveyance, royalty, taxes of all materials with all labour, T&P required etc. complete & as per direction of theEngineer-in-Charge. (AR-2006, Page - 204, item no. - 7) |
| 208 | SERVICE ROAD |
| 209 | EARTH WORK |
| 210 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 211 | Ordinary Soil |
| 212 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 213 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 214 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 215 | Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P,sundries and scaffolding required for the work etc. as directed by the Engineer-in- charge. |
| 216 | Drain |
| 217 | Providing and laying at or near ground level factory made kerb stone of M-30 grade (450x300x150mm) cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge. |
| 218 | Providing and laying 80mm thick faciory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 219 | PATHWAY |
| 220 | EARTH WORK |
| 221 | Clearing and grubbing road land including uprooting rank vegitation grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of tree cut earlier and disposal of unservicable material and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 222 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 223 | Ordinary Soil |
| 224 | Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road &Bridge works |
| 225 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 226 | Providing and laying P.C.C[1:3:6] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 227 | Pathway |
| 228 | Stone crete plaster with stone size upto 6mm, thickness upto 12mm |
| 229 | Groove with wooden patti |
| 230 | Groove with U-Channel with thickness of 10 to 12mm |
| 231 | FENCING AROUND ALL ENCLOSERS |
| 232 | EARTH WORK |
| 233 | Earth work in stoney earth and gravels mixed with stone and boulder not exceeding 0.014 cum in volume within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layer not exceeding 0.3m in depth and as per specification approved by the dept. |
| 234 | Ordinary Soil |
| 235 | Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. |
| 236 | Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 237 | PLAIN & REINFORCEMENT CONCRETE |
| 238 | Providing and laying P.C.C[1:4:8] using 4cm size metal etc in foundation and floors using cement , 40 mm size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting ,lowering and laying concrete to the required level, ramming ,watering and curing etc |
| 239 | Providing and laying in position ready mixed M25 grade concrete having compressive strength at 28 days test not lessthan 250kg/sq.cm for reinforced cement concrete work using cement content as per approved design mix etc including Rigid & smooth centering and shuttering. |
| 240 | For R.C.C foundation, footing bases of column, mass concrete,pre-cast etc. |
| 241 | Providing M.S reinforcement for R.C.C work including cutting, bending, and tying the grlls and placing in position including cost of binding wire 18 to 22 gauge etc. complete as per the direction of the Engineer-in-Charge |
| 242 | Foundation |
| 243 | Painting with synthetic enamel paint over a coat of primer of approved colour, shade and brand on New wood work /steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete. |
| 244 | Ground floor |
| 245 | Supplying and fixing of G.I. chain link mesh (TATA) of size ( 2\\" x 2\\" x 10 Gauge) to cover the Exhibit area including all cost conveyance of materials and labour with labour cess royalty, transportation loading & unloading , cost , T&P etc. required for the work all complete in all respect as per direction of the Engineer in charge . |
| 246 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction bolt welded tubes etc. complete as directed by the Engineer-in-Charge. |
| 247 | ARTISTIC STAND-OFF BARRIER |
| 248 | PH WORKS |
| 249 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge. Ground Floor 25mm dia PVC ASTM pipe (sch-80) (Ashirbad /Astral/Supreeme) |
| 250 | 32mm dia PVC ASTM pipe (sch-80) |
| 251 | 50mm dia PVC ASTM pipe (sch-80) |
| 252 | 100mm dia PVC ASTM pipe (sch-80) |
| 253 | Supplying all materials, labour, T&P and providing and fixing to the wall or ceiling and floor CPVC pipes conforming to IS:15778, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00. spacing. This includes the jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge. (Supreem/Ashirvad/Oriplast/AKG) Ground Floor- 20mm dia CPVC pipe. |
| 254 | 25mm dia CPVC pipe |
| 255 | 32mm dia CPVC pipe |
| 256 | Supplying, fixing, testing and commissioning of Cast Iron butterfly valve of PN 1.0 rating with SS-316 seat, Shaft SS-316 duly ISI marked complete with SS bolts & nuts, washers, gaskets conforming to IS 13095 of following sizes as required and two matching flanges as per table 'E' etc. |
| 257 | 100 mm nominal bore |
| 258 | 25mm dia brass or gun metal fullway valve(shakti /equivalent Make) |
| 259 | 15mm dia CP Long body bib cock(Jaquar/Cera/hindware/equivalent Make) Hindware-F690006 |
| 260 | External PH Swerage System |
| 261 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4984/2016 of the following outside dia for Pressure rating PN-6 including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 262 | 160mm dia u-pvc pipe alround concrete |
| 263 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 900mmx800mmx450mm |
| 264 | Inside size 900mmx800mmx450mm |
| 265 | R.C.P.C.Manhole Cover |
| 266 | Constructing masonry Valve Chamber 60 x 60 x 75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for Valve chamber, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and180 mm deep (inside) with chain lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. |
| 267 | Supplying all materials,labour,T&P and fixing 2000 ltr Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.In First floor |
| 268 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.20m dia x 2.00m deep soakway pit. |
| 269 | (SH: INTERNAL ELECTICAL WORK WITH FITTINGS.-CAGE-I) |
| 270 | WIRING-: |
| 271 | Recess Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 1way modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required including the cost of labor & material T & P as required as EIC. |
| 272 | First Point |
| 273 | Group A |
| 274 | Group B |
| 275 | Group C |
| 276 | Looping Point .(Looping Point) |
| 277 | (Controled by same switch-with Gr.A wire quantity Only) |
| 278 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including the cost of labor & material T & P as required as EIC. |
| 279 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP looping & UPS lighting,BDB to basement & stilt Light Points. |
| 280 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points |
| 281 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC & Geyser Point.& EL+C DB wiring |
| 282 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including the cost of labor & material T & P as required as EIC. |
| 283 | 25 mm |
| 284 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit ,also including painting etc as required including the cost of labor & material T & P as required as EIC. |
| 285 | 75 mm X 75 mm X 60 mm deep |
| 286 | 100 mm X 100 mm X 60 mm deep |
| 287 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 288 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 289 | Installation, testing and commissioning of wall bracket /ceiling fittings /Hanging/Linear Hanging/LED down light/Occupancy sensor of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 290 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required including the cost of labor & material T & P as required as EIC. |
| 291 | SDB'S, MCB, ISOLATOR,CABLE,PANELS-: |
| 292 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required including the cost of labor & material T & P as required as EIC. (But without MCB/RCCB/Isolator) |
| 293 | 8 way (2 + 6), Double door |
| 294 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including the cost of labor & material T & P as required as EIC. (But without MCB/RCCB/Isolator) |
| 295 | Single pole |
| 296 | Single pole & Neutral |
| 297 | Supplying the following Size ISI mark Aluminum conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required including the cost of material T & P as required as EIC. |
| 298 | a- 3 core 6 sq.mm |
| 299 | Laying and fixing of one number of following size of cable on wall surface as required, ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 300 | 25 sq. mm and upto 120 sq. mm |
| 301 | Laying and fixing of one number .following size cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 302 | upto 25 sq. mm |
| 303 | Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required. |
| 304 | 3 core 6 sq.mm |
| 305 | Panels . |
| 306 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, nterconnections, earthing, etc. as required as per direction of Engineer in Charge |
| 307 | Earthing |
| 308 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 309 | Supplying and laying 6 SWG G.I. wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering etc. as required |
| 310 | FITTING & FIXTURE-: |
| 311 | Supply, Installation, Testing, and commissioning of 400mm sweep energy efficient Wall mounted fan complete with 1.5 sq.mm PVC insulated, copper conductor,single core cable etcincluding the cost of material ,labor T & P as required as EIC. |
| 312 | Supply, Testing & commissioning of Surface or wall mounting 1 x 20W LED tube light fitting (5700K) including 1 no. of 20watt LED luminairs as per EIC of approved make including the cost of material ,labor T & P as required as EIC. (Make-Wipro/Philips/Leksa/LT/Jaquar/Havells/Bajaj) |
| 313 | Supply, Installation,Testing & commissioning of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,with 35mm angled pole type fixing chanel for fixing on the parapet wall,clamp & nut bolt connecting wire all accessories (Make-Wipro/Philips/Leksa/LT/Jaquar/Havells/Bajaj) |
| 314 | (SH: INTERNAL ELECTICAL WORK WITH FITTINGS.-CAGE-II) |
| 315 | WIRING-: |
| 316 | Recess Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 1way modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required including the cost of labor & material T & P as required as EIC. |
| 317 | First Point |
| 318 | Group A |
| 319 | Group B |
| 320 | Group C |
| 321 | Looping Point .(Looping Point) |
| 322 | (Controled by same switch-with Gr.A wire quantity Only) |
| 323 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including the cost of labor & material T & P as required as EIC. |
| 324 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP looping & UPS lighting,BDB to basement & stilt Light Points. |
| 325 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points |
| 326 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC & Geyser Point.& EL+C DB wiring |
| 327 | 2 X 6.0 sq. mm + 1 X 4 sq. mm earth wire for UPS wiring |
| 328 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including the cost of labor & material T & P as required as EIC. |
| 329 | 25 mm |
| 330 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit ,also including painting etc as required including the cost of labor & material T & P as required as EIC. |
| 331 | 75 mm X 75 mm X 60 mm deep |
| 332 | 100 mm X 100 mm X 60 mm deep |
| 333 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 334 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 335 | Installation, testing and commissioning of wall bracket /ceiling fittings /Hanging/Linear Hanging/LED down light/Occupancy sensor of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 336 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required including the cost of labor & material T & P as required as EIC. |
| 337 | SDB'S, MCB, ISOLATOR,CABLE,PANELS-: |
| 338 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required including the cost of labor & material T & P as required as EIC. (But without MCB/RCCB/Isolator) |
| 339 | 8 way (2 + 6), Double door |
| 340 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including the cost of labor & material T & P as required as EIC. (But without MCB/RCCB/Isolator) |
| 341 | Single pole |
| 342 | Single pole & Neutral |
| 343 | Supplying the following Size ISI mark Aluminum conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required including the cost of material T & P as required as EIC. |
| 344 | a- 3 core 6 sq.mm |
| 345 | Laying and fixing of one number of following size of cable on wall surface as required, ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 346 | 25 sq. mm and upto 120 sq. mm |
| 347 | Laying and fixing of one number .following size cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 348 | upto 25 sq. mm |
| 349 | Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required. |
| 350 | 3 core 6 sq.mm |
| 351 | Panels . |
| 352 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, nterconnections, earthing, etc. as required as per direction of Engineer in Charge |
| 353 | Earthing |
| 354 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 355 | Supplying and laying 6 SWG G.I. wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering etc. as required |
| 356 | FITTING & FIXTURE-: |
| 357 | Supply, Installation, Testing, and commissioning of 400mm sweep energy efficient Wall mounted fan complete with 1.5 sq.mm PVC insulated, copper conductor,single core cable etcincluding the cost of material ,labor T & P as required as EIC. |
| 358 | Supply, Testing & commissioning of Surface or wall mounting 1 x 20W LED tube light fitting (5700K) including 1 no. of 20watt LED luminairs as per EIC of approved make including the cost of material ,labor T & P as required as EIC. (Make-Wipro/Philips/Leksa/LT/Jaquar/Havells/Bajaj) |
| 359 | Supply, Installation,Testing & commissioning of 25 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,with 35mm angled pole type fixing chanel for fixing on the parapet wall,clamp & nut bolt connecting wire all accessories (Make-Wipro/Philips/Leksa/LT/Jaquar/Havells/Bajaj) |
| 360 | SH-E.I WORK ( EARTHING,EXTERNAL -PANEL & CABLES) |
| 361 | (Earthing) INSTALLATION |
| 362 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of material ,labor T & P as required as EIC. |
| 363 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required including the cost of material ,labor T & P as required as EIC. |
| 364 | Supply, delivery & installation of GI coil earthing made out of 8 swg GI wire closely wound in shape of a helical coil of 50mm diameter with 115 numbers of turns including excavation of earthpit of size 800x 800x 1500mm in all kinds of soil, back filling the excavated pit with alternate layers of salt, charcoal around the coil with a diameter of 300mm upto 1000mm and balance by good quality soil, end termination complete as required. |
| 365 | CABLING AND END TERMINATION MAIN AREA |
| 366 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 367 | 3core x 6 sq mm |
| 368 | 3core x 10 sq mm |
| 369 | 3.5core x35 sq mm |
| 370 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI |
| 371 | LAYING OF CABLE |
| 372 | Laying and fixing of one number of following size of cable on wall surface as required, ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 373 | 25 sq. mm and upto 120 sq. mm |
| 374 | Laying and fixing of one number .following size cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required |
| 375 | upto 25 sq. mm |
| 376 | Above 25 sq. mm and upto 120 sq. mm |
| 377 | Above 120 sq. mm and upto 400 sq. mm |
| 378 | Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required. |
| 379 | 3core x 6/10 sq mm |
| 380 | 3.5core x 35 sq mm |
| 381 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 382 | 50 mm dia |
| 383 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 384 | 200 mm dia |
| 385 | 63mm dia |
| 386 | Providing, laying and fixing following dia RCC pipeNP2 class (light duty) in ground complete with RCCcollars, jointing with cement mortar 1:2 (1 cement : 2fine sand) including trenching (75 cm deep) andrefilling etc as required.(100 mm dia) |
| 387 | PANELS & FEEDERS |
| 388 | Supplying,installation,testing & commissioning of LT OUT DOOR(MAIN PANEL-NEAR DG) FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40ka shall be installed in the incomer. 20X5MM Separate Aluminium Earth bus bar should be installed.In commer- 01 no 100A 4P MCCB 16kA,C series with on/off trip indication. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA))In commer- 01 no 100A 4P Off Loaf C/O switchBusbar- 04 numbers of 150Amps Al bus bar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 02 nos 32A 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB201Out going- 13 nos 32A 2P MCB 10kA,C series Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB202Instrument- (i) 0-100A Digital MFM with CT & PT & 03 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 389 | LIGHTS & POLES |
| 390 | Supplying and Fixing of Street light- 70W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make-K-Lite/Wipro/Homdec/Leksa/LT/Jaquar/Havells/Bajaj) |
| 391 | Supplying and Fixing of 6mtr long hot dip Galvanized Octagonal pole with in built Jb for power connection,manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate,1.5mtr Bracket for mounting light, including the cost of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/VAKRANGEE/Homdec/K-lite /Leksa as per direction of Engg. in Charge. |
| 392 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 393 | The item rates indicated aove work inclusive of cost of all labour, materials,conveyence,taxes and royality(with EMF,DMF and additional charges) of materials,labour cess,here and running charges of all machineries and equipments and other incidental charges so as to complete the item in all respect as per specification and direction of Engineer-In-Charge.Accordingly the bidder has to quote the rates.The rate are exclusive of GST as applicable. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender