Housing Urban and Rular Development Government Departments Closing in 9 days TDR #58466395

Tender For Shifting Of Electrical Infrastructure For The Work Improvement Such As Widening & Strengthening Of Sanabutupali-Panthei Road From 0/000 Km To 14/900 Km In The District Of Boudh Under State Plan.

Issued by Government Departments · Boudh, Odisha
Tender Value
82.94 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
9 days left
EMD
82947
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Boudh → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shifting Of Electrical Infrastructure For The Work Improvement Such As Widening & Strengthening Of Sanabutupali-Panthei Road From 0/000 Km To 14/900 Km In The District Of Boudh Under State Plan.

BOQ

Name of Work:- Shifting of electrical infrastructure for the work Improvement such as widening & strengthening of Sanabutupali-Panthei road from 0/000 km to 14/900 Km in the District of Boudh under State Plan.
Sl. No. Item Description
1SLD-1 PART I: Construction of OH HT line with 1Cx55 sq.mm XLPE insulated covered conductor on cantilever arrangement, 0.56 Km (A-B), avg span 40 Mtr, with 11 Mtr WPB polesSLD-1 PART I: Construction of OH HT line with 1Cx55 sq.mm XLPE insulated covered conductor on cantilever arrangement, 0.56 Km (A-B), avg span 40 Mtr, with 11 Mtr WPB poles1. Supply of materialsWPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART I (SLD-1)
2Earthing Coil for support PART I (SLD-1)
3No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-1)
4100x50x6 mm GI channel for straight Cross arm 1.4 mtr each 3 Nos Each on Pin Point Pole for Cantilever arrangement & 6 Nos Each for CP arrangment on Cantiliver arrangement PART I (SLD-1)
5Mounting GI Channel 75x40x6 -1.4 mtr. long, 1 no. Each for Pin Point Pole & 2 Nos Each for CP arrangement (@6.8K.g/mtr) for supporting the cantilever arrangement PART I (SLD-1)
6Cantilever Angel for supporting Cantilver arrangement 50x50x6 mm GI Angel (1.0mtr Long 13Nos.) (@4.5K.g/mtr) PART I (SLD-1)
7GI Back Clamp Cross Arm PART I (SLD-1)
811KV XLPE COVERED CONDUCTOR 55 SQMM,AAA PART I (SLD-1)
9Disc insulator (B&S) 45 KN polymer PART I (SLD-1)
10Tension Assembly Wedge Type with Anchoring Clamp for 11 kV covered conductor PART I (SLD-1)
11IPC for Covered Conductor 11 KV 55 Sqmm PART I (SLD-1)
1211KV pin insulator polymer PART I (SLD-1)
13Non-Metallic Ties 11KV(for covered conductor) PART I (SLD-1)
14Mechanical Connector with Heat Shirnk Sleeve for 11KV 55sqmm AAA Covered Conductor PART I (SLD-1)
15H.T.stay set ( Complete ) PART I (SLD-1)
16H.T. Stay Insulator PART I (SLD-1)
17H.T. Stay clamp (1.95 Kg./ Pair ) PART I (SLD-1)
187/10 SWG Stay Wire PART I (SLD-1)
19Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-1)
20Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back PART I (SLD-1)
21Clamp(4pc/support). Danger Board PART I (SLD-1)
22Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-1)
23GI nuts, bolts and washers PART I (SLD-1)
24Black Paint PART I (SLD-1)
25Yellow Colour Paint for Background PART I (SLD-1)
26Sundries ( Clamp, Connectors, Binding tape etc) PART I (SLD-1)
27WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART II (SLD-1)
28Earthing Coil for support PART II (SLD-1)
29No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-1)
30Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART II (SLD-1)
31AB Switch mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART II (SLD-1)
32AB switch side support channel 100X50X6 mm,9.2 Kg/Mtr ,each channel length 0.35M,2 nos channel required PART II (SLD-1)
33Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART II (SLD-1)
34GI chanel for supporting DP arm, 75x40x6 2.8 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART II (SLD-1)
35Bracing angle (50x50x6) MM GI angle, 4.0 Mtr. long, 2Nos. (4.5kg/mtr) PART II (SLD-1)
36Disc insulator (B&S)45 KN polymer PART II (SLD-1)
37Tension Assembly Wedge Type with Anchoring Clamp for 11 kV covered conductor PART II (SLD-1)
38Mechanical Connector with Heat Shirnk Sleeve for 11KV 55sqmm AAA Covered Conductor PART II (SLD-1)
3911KV pin insulator polymer PART II (SLD-1)
40Non-Metallic Ties 11KV(for covered conductor) PART II (SLD-1)
4111 KV AB switch 3 Pole 400Amp PART II (SLD-1)
4211 KV Lightning Arrestor 9KV 10KA PART II (SLD-1)
43IPC for 55 sqmm AAA conductor(for covered conductor) PART II (SLD-1)
44HT Stay Set Complete PART II (SLD-1)
45HT Stay insulator PART II (SLD-1)
46HT Stay clamp for PSC Pole (1.9Kg/pair) PART II (SLD-1)
477/10 SWG GI Stay wire PART II (SLD-1)
48Danger Board PART II (SLD-1)
49Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-1)
50G.I pipe Earthing 40 mm dia medium gauge (3.25mm thick ness) 3 mtr long PART II (SLD-1)
5150x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36 PART II (SLD-1)
52Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART II (SLD-1)
53Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART II (SLD-1)
54GI nuts,bolts and washers PART II (SLD-1)
55Black Paint PART II (SLD-1)
56Yellow Colour Paint for Background PART II (SLD-1)
57Sundries ( Clamp, Connectors, Binding tape etc PART II (SLD-1)
589 Mtr long 300 KG PSC pole PART III (SLD-1)
59RCC Base Plate PART III (SLD-1)
60Earthing device Coil type (GI) PART III (SLD-1)
61No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART III (SLD-1)
62100x50x6 mm channel for straight Cross arm 1.2 mtr each 16 no & 0.2 mtr long 16 No. ( 4cut point) &(02 no of Tapping Point) @ 9.2Kg/Mtr PART III (SLD-1)
6311KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART III (SLD-1)
64GI Back Clamp for 11KV \\"V \\"Cross Arm PART III (SLD-1)
6511KV F Clamp 2.9 kg Each (with galvanisation) PART III (SLD-1)
6611KV pin insulator polymer PART III (SLD-1)
6755mm2 AAAC PART III (SLD-1)
68Disc insulator (B&S)45 KN polymer PART III (SLD-1)
69H W fitting (B&S)2 bolted PART III (SLD-1)
70PG clamp for 55 mm2 AAA conductor PART III (SLD-1)
71Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART III (SLD-1)
72H.T.stay set ( Complete ) PART III (SLD-1)
73H.T. Stay Insulator PART III (SLD-1)
74H.T. Stay clamp (1.95 Kg./ Pair ) PART III (SLD-1)
757/10 SWG Stay Wire PART III (SLD-1)
76Anticlimbing Device(GI barbed wire 3kg per support) PART III (SLD-1)
77Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART III (SLD-1)
78Danger Board PART III (SLD-1)
79Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART III (SLD-1)
80GI nuts, bolts and washers PART III (SLD-1)
81Black Paint PART III (SLD-1)
82Yellow Colour Paint for Background PART III (SLD-1)
83Sundries ( Clamp, Connectors, Binding tape etc) PART III (SLD-1)
849 Mtr long 300 KG PSC pole PART IV (SLD-1)
85RCC Base Plate PART IV (SLD-1)
86Earthing device Coil type (GI) PART IV (SLD-1)
87No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART IV (SLD-1)
88Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART IV (SLD-1)
89Transformer mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART IV (SLD-1)
90AB Swith & HG Fuse, Mounting GI Channel 75x40x6 -2.8 mtr.long, 4 nos.(@6.8K.g/mtr) PART IV (SLD-1)
91Cantilever GI chanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART IV (SLD-1)
92Cantilever Angel for supporting AB switch 50x50x6 mm GI Angel (1.0mtr Long 2Nos.) (@4.5K.g/mtr) PART IV (SLD-1)
93Transformer belting GI Angel 50x50x6mm - 2.8mtr Long 2nos. (@4.5K.g/mtr) with side angel (Total 7mtr.) PART IV (SLD-1)
94Angle for mounting LT distribution Box 50x50x 6mm GI Angel -1mtrs.each Long 2Nos.( @4.5K.g/mtr) PART IV (SLD-1)
95AB Switch Side Support Channel 100X50X6mm,9.2KG/Mtr., each channel length 0.35 mtr., 2 no's channel required PART IV (SLD-1)
96Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART IV (SLD-1)
9711KV Disc Insulator B&S Type 45KN Ploymer PART IV (SLD-1)
98Hard ware fitting B&S Type 45KN (2Bolted) PART IV (SLD-1)
9911KV AB Switch 3 Pole (200 Amp) PART IV (SLD-1)
10011KV HG Fuse 3 Pole (200 Amp) PART IV (SLD-1)
101Lightning arrester (9KV, 5Ka) PART IV (SLD-1)
102H.T.stay set ( Complete ) PART IV (SLD-1)
103H.T. Stay Insulator PART IV (SLD-1)
104H.T. Stay clamp (1.95 K.g./ Pair ) PART IV (SLD-1)
1057/10 SWG Stay Wire PART IV (SLD-1)
106GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART IV (SLD-1)
10725x4mm GI Flat (Neutral) PART IV (SLD-1)
10825x6mm GI Flat PART IV (SLD-1)
10955mm2 AAAC PART IV (SLD-1)
110PG clamp for 55 mm2 AAA conductor PART IV (SLD-1)
111GI Nut , Bolt & Washer PART IV (SLD-1)
112LT Distribution Box with MCCB, Aluminium busbar for 2- Bay with kitkat fuse for 100 KVA S/S PART IV (SLD-1)
1131Cx185 mm2 LT XLPE Cable (Armoured) @15 Mtr Each (15Mtr X4=60 Mtr ) as desired by Section Head PART IV (SLD-1)
114Danger Board PART IV (SLD-1)
115Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART IV (SLD-1)
116Anticlimbing Device(GI barbed wire 3kg per support) PART IV (SLD-1)
117Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART IV (SLD-1)
118Black Paint PART IV (SLD-1)
119Yellow Colour Paint for Background PART IV (SLD-1)
120Sundries (Almunium binding tape, Insulating tape, Binding Tape Allm. Cable Socket etc. ) PART IV (SLD-1)
1218 Mtr long 300 KG PSC pole PART V (SLD-1)
122RCC Base Plate PART V (SLD-1)
123Earthing support coil type PART V (SLD-1)
124No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART V (SLD-1)
125LT Stay Set complete PART V (SLD-1)
126LT Stay Insulator PART V (SLD-1)
127LT Stay clamp PART V (SLD-1)
1287/12 SWG Stay Wire PART V (SLD-1)
1293x95+1x70+1x16 mm2 LT XLPE Aerial bunched Cable PART V (SLD-1)
1303x35+1x25 mm2 AB Cable PART V (SLD-1)
131Pole clamp for I hook ( on existing HT Pole 13 Nos + 9 Nos for New LT line with 8 Mtr PSC Pole) PART V (SLD-1)
132Dead end clamp +I hook PART V (SLD-1)
133Suspension clamp with I hook PART V (SLD-1)
134Danger board PART V (SLD-1)
135Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART V (SLD-1)
136Anticlimbing Device(GI barbed wire 3kg per support) PART V (SLD-1)
137Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART V (SLD-1)
138GI Nuts,Bolts & Washers PART V (SLD-1)
139Black Paint PART V (SLD-1)
140Yellow Colour Paint for Background PART V (SLD-1)
141Sundries PART V (SLD-1)
14275x40x6 mm GI Channel Straight cross arm 3.2mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART VI (SLD-1)
143No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART VI (SLD-1)
14440mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr. long PART VI (SLD-1)
14525x6 GI flat for earthing,1.2 kg/mtr PART VI (SLD-1)
146GI nuts, bolts and washers PART VI (SLD-1)
147Eye hook for cradle guard PART VI (SLD-1)
148Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-1)
149Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-1)
150Concreting of 9mtr /8Mtr poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-1)
151Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-1)
152Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-1)
153Construction of Boundary wall boundry for fencing of DPM S/S in the size of 3x3 mtr @7300.12/RM considering height above ground level-1.65 mtr & below ground depth-1.2 mtr including the cost of fabrication, installation of MS Gate (1.5x1.65) (As per mail received from NEP dept.) PART D (SLD-1)
154Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-1)
155Survey and digitization of New DSS and its internals including attrubutes PART D (SLD-1)
1562. Dismantling worksDismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-1)
157Dismantling of 09/11 Mtr. Joist/WPB Pole- 116X100mm (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-1)
158Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-1)
159Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-1)
160Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer below 100KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-1)
161Dismantle-Steel Structure of lines & S/s PART D (SLD-1)
162Dismantling of 11 kV /33KV GO/AB Switch/Isolator/DD fuse/fuse set including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store(Note Set =Three phase). PART D (SLD-1)
1639 Mtr long 300 KG PSC pole PART I (SLD-2)
164RCC Base Plate PART I (SLD-2)
165Earthing Coil for support PART I (SLD-2)
166No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-2)
167100x50x6 mm GI channel for straight Cross arm 1.4 mtr each 2 Nos Each for 02 Nos Cut Polint arrangement PART I (SLD-2)
16811KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART I (SLD-2)
169GI Back Clamp for 11KV \\"V \\"Cross Arm PART I (SLD-2)
17011KV F Clamp 2.9 kg Each (with galvanisation) PART I (SLD-2)
17111KV pin insulator polymer PART I (SLD-2)
17255mm2 AAAC PART I (SLD-2)
173Disc insulator (B&S)45 KN polymer PART I (SLD-2)
174H W fitting (B&S)2 bolted PART I (SLD-2)
175PG clamp for 55 mm2 AAA conductor PART I (SLD-2)
176Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART I (SLD-2)
177H.T.stay set ( Complete ) PART I (SLD-2)
178H.T. Stay Insulator PART I (SLD-2)
179H.T. Stay clamp (1.95 Kg./ Pair ) PART I (SLD-2)
1807/10 SWG Stay Wire PART I (SLD-2)
181Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-2)
182Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART I (SLD-2)
183Danger Board PART I (SLD-2)
184Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-2)
185GI nuts, bolts and washers PART I (SLD-2)
186Black Paint PART I (SLD-2)
187Yellow Colour Paint for Background PART I (SLD-2)
188Sundries ( Clamp, Connectors, Binding tape etc) PART I (SLD-2)
189WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART II (SLD-2)
190Earthing device Coil type (GI) PART II (SLD-2)
191No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-2)
192100x50x6 mm channel for straight Cross arm 1.2 mtr each 6 no & 0.2 mtr long 6 No. ( 3cut point) & (02 no of Tapping Point) @ 9.2Kg/Mtr PART II (SLD-2)
19311KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART II (SLD-2)
194GI Back Clamp for 11KV \\"V \\"Cross Arm PART II (SLD-2)
19511KV F Clamp 2.9 kg Each (with galvanisation) PART II (SLD-2)
19611KV pin insulator polymer PART II (SLD-2)
19755mm2 AAAC PART II (SLD-2)
198Disc insulator (B&S)45 KN polymer PART II (SLD-2)
199H W fitting (B&S)2 bolted PART II (SLD-2)
200PG clamp for 55 mm2 AAA conductor PART II (SLD-2)
201Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART II (SLD-2)
202H.T.stay set ( Complete ) PART II (SLD-2)
203H.T. Stay Insulator PART II (SLD-2)
204H.T. Stay clamp (1.95 Kg./ Pair ) PART II (SLD-2)
2057/10 SWG Stay Wire PART II (SLD-2)
206Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-2)
207Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART II (SLD-2)
208Danger Board PART II (SLD-2)
209Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-2)
210GI nuts, bolts and washers PART II (SLD-2)
211Black Paint PART II (SLD-2)
212Yellow Colour Paint for Background PART II (SLD-2)
213Sundries ( Clamp, Connectors, Binding tape etc) PART II (SLD-2)
2149 Mtr long 300 KG PSC pole PART III (SLD-2)
215RCC Base Plate PART III (SLD-2)
216Earthing device Coil type (GI) PART III (SLD-2)
217No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART III (SLD-2)
218Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART III (SLD-2)
219Transformer mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART III (SLD-2)
220AB Switch & HG Fuse, Mounting GI Channel 75x40x6 -2.8 mtr.long, 4 nos.(@6.8K.g/mtr) PART III (SLD-2)
221Cantilever GI chanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART III (SLD-2)
222Cantilever Angel for supporting AB switch 50x50x6 mm GI Angel (1.0mtr Long 2Nos.) (@4.5K.g/mtr) PART III (SLD-2)
223Transformer belting GI Angel 50x50x6mm - 2.8mtr Long 2nos. (@4.5K.g/mtr) with side angel (Total 7mtr.) PART III (SLD-2)
224Angle for mounting LT distribution Box 50x50x 6mm GI Angel -1mtrs.each Long 2Nos.( @4.5K.g/mtr) PART III (SLD-2)
225AB Switch Side Support Channel 100x50x6mm, 9.2KG/Mtr., each channel length 0.35 mtr., 2 no's channel required PART III (SLD-2)
226Channel Support for down Pipe 75x40x6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART III (SLD-2)
22711KV Disc Insulator B&S Type 45KN Polymer PART III (SLD-2)
228Hard ware fitting B&S Type 45KN (2Bolted) PART III (SLD-2)
22911KV AB Switch 3 Pole (200 Amp) PART III (SLD-2)
23011KV HG Fuse 3 Pole (200 Amp) PART III (SLD-2)
231Lightning arrester (9KV, 5Ka) PART III (SLD-2)
232H.T.stay set ( Complete ) PART III (SLD-2)
233H.T. Stay Insulator PART III (SLD-2)
234H.T. Stay clamp (1.95 K.g./ Pair ) PART III (SLD-2)
2357/10 SWG Stay Wire PART III (SLD-2)
236GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART III (SLD-2)
23725x4mm GI Flat (Neutral) PART III (SLD-2)
23825x6mm GI Flat PART III (SLD-2)
23955mm2 AAAC PART III (SLD-2)
240PG clamp for 55 mm2 AAA conductor PART III (SLD-2)
241GI Nut , Bolt & Washer PART III (SLD-2)
242LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S PART III (SLD-2)
2431Cx70 mm2 LT,XLPE Cable (Un- armoured) 4nos 10mtr each PART III (SLD-2)
244Danger Board PART III (SLD-2)
245Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART III (SLD-2)
246Anticlimbing Device(GI barbed wire 3kg per support) PART III (SLD-2)
247Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART III (SLD-2)
248Black Paint PART III (SLD-2)
249Yellow Colour Paint for Background PART III (SLD-2)
250Sundries (Almunium binding tape, Insulating tape, Binding Tape Allm. Cable Socket etc. ) PART III (SLD-2)
2519 Mtr long 300 KG PSC pole PART IV (SLD-2)
2528 Mtr long 200 KG PSC pole PART IV (SLD-2)
253RCC Base Plate PART IV (SLD-2)
254Earthing support coil type PART IV (SLD-2)
255No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART IV (SLD-2)
256LT Stay Set complete PART IV (SLD-2)
257LT Stay Insulator PART IV (SLD-2)
258LT Stay clamp PART IV (SLD-2)
2597/12 SWG Stay Wire PART IV (SLD-2)
2603x35+1x25 mm2 AB Cable PART IV (SLD-2)
261Pole clamp for I hook PART IV (SLD-2)
262Dead end clamp +I hook PART IV (SLD-2)
263Suspension clamp with I hook PART IV (SLD-2)
264Danger board PART IV (SLD-2)
265Back Clamp for Danger Board (25x3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART IV (SLD-2)
266Anticlimbing Device(GI barbed wire 3kg per support) PART IV (SLD-2)
267Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART IV (SLD-2)
268GI Nuts,Bolts & Washers PART IV (SLD-2)
269Black Paint PART IV (SLD-2)
270Yellow Colour Paint for Background PART IV (SLD-2)
271Sundries PART IV (SLD-2)
27275x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART V (SLD-2)
273No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART V (SLD-2)
27440mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART V (SLD-2)
27525x6 GI flat for earthing,1.2 kg/mtr PART V (SLD-2)
276GI nuts, bolts and washers PART V (SLD-2)
277Eye hook for cradle guard PART V (SLD-2)
278Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-2)
279Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-2)
280Concreting of 9mtr /8Mtr poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-2)
281Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-2)
282Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-2)
283Construction of Boundary wall boundry for fencing of DPM S/S in the size of 3x3 mtr @7300.12/RM considering height above ground level-1.65 mtr & below ground depth-1.2 mtr including the cost of fabrication, installation of MS Gate (1.5x1.65) (As per mail received from NEP dept.) PART D (SLD-2)
284Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-2)
285Survey and digitization of New DSS and its internals including attrubutes PART D (SLD-2)
286Dismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-2)
287Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-2)
288Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-2)
289Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 25KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-2)
290Dismantle-Steel Structure of lines & S/s PART D (SLD-2)
291WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART I (SLD-3)
292Earthing Coil for support PART I (SLD-3)
293No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-3)
294100x50x6 mm channel for straight Cross arm 1.2 mtr each 4 no & 0.2 mtr long 4 No. ( 1cut point) PART I (SLD-3)
295Disc insulator (B&S) 45 KN polymer PART I (SLD-3)
296H W fitting (B&S)2 bolted PART I (SLD-3)
297PG clamp for 55 mm2 AAA conductor PART I (SLD-3)
298Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART I (SLD-3)
29911KV pin insulator polymer PART I (SLD-3)
30055mm2 AAAC PART I (SLD-3)
301H.T.stay set ( Complete ) PART I (SLD-3)
302H.T. Stay Insulator PART I (SLD-3)
303H.T. Stay clamp (1.95 Kg./ Pair ) PART I (SLD-3)
3047/10 SWG Stay Wire PART I (SLD-3)
305Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-3)
306Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART I (SLD-3)
307Danger Board PART I (SLD-3)
308Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-3)
309GI nuts, bolts and washers PART I (SLD-3)
310Black Paint PART I (SLD-3)
311Yellow Colour Paint for Background PART I (SLD-3)
312Sundries PART I (SLD-3)
313WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART II (SLD-3)
314Earthing Coil for support PART II (SLD-3)
315No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-3)
316Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART II (SLD-3)
317Transformer mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART II (SLD-3)
318AB Swith & HG Fuse, Mounting GI Channel 75x40x6 - 2.8 mtr.long, 4 nos.(@6.8K.g/mtr) PART II (SLD-3)
319Cantilever GI chanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART II (SLD-3)
320Cantilever Angel for supporting AB switch 50x50x6 mm GI Angel (1.0mtr Long 2Nos.) (@4.5K.g/mtr) PART II (SLD-3)
321Transformer belting GI Angel 50x50x6mm - 2.8mtr Long 2nos. (@4.5K.g/mtr) with side angel (Total 7mtr.) PART II (SLD-3)
322Angle for mounting LT distribution Box 50x50x 6mm GI Angel -1mtrs.each Long 2Nos.( @4.5K.g/mtr) PART II (SLD-3)
323AB Switch Side Support Channel 100X50X6mm,9.2KG/Mtr., each channel length 0.35 mtr., 2 no's channel required PART II (SLD-3)
324Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART II (SLD-3)
32511KV Disc Insulator B&S Type 45KN Ploymer PART II (SLD-3)
326Hard ware fitting B&S Type 45KN (2Bolted) PART II (SLD-3)
32711KV AB Switch 3 Pole (200 Amp) PART II (SLD-3)
32811KV HG Fuse 3 Pole (200 Amp) PART II (SLD-3)
329Lightning arrester (9KV, 5Ka) PART II (SLD-3)
330H.T.stay set ( Complete ) PART II (SLD-3)
331H.T. Stay Insulator PART II (SLD-3)
332H.T. Stay clamp (1.95 K.g./ Pair ) PART II (SLD-3)
3337/10 SWG Stay Wire PART II (SLD-3)
334GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART II (SLD-3)
33525x4mm GI Flat (Neutral) PART II (SLD-3)
33625x6mm GI Flat PART II (SLD-3)
33755mm2 AAAC PART II (SLD-3)
338PG clamp for 55 mm2 AAA conductor PART II (SLD-3)
339GI Nut , Bolt & Washer PART II (SLD-3)
340LT Distribution Box with MCCB, Aluminium busbar for 2- Bay with kitkat fuse for 100 KVA S/S PART II (SLD-3)
3411Cx185 mm2 LT XLPE Cable (Armoured) @15 Mtr Each (15Mtr X4=60 Mtr ) as desired by Section Head PART II (SLD-3)
342Danger Board PART II (SLD-3)
343Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART II (SLD-3)
344Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-3)
345Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART II (SLD-3)
346Black Paint PART II (SLD-3)
347Yellow Colour Paint for Background PART II (SLD-3)
348Sundries (Almunium binding tape, Insulating tape, Binding Tape Allm. Cable Socket etc. ) PART II (SLD-3)
34910 Mtr long 330kg PSC pole (including transportation cost upto store) PART III (SLD-3)
350RCC Base Plate PART III (SLD-3)
351Earthing support coil type PART III (SLD-3)
352No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART III (SLD-3)
353LT Stay Set complete PART III (SLD-3)
354LT Stay Insulator PART III (SLD-3)
355LT Stay clamp PART III (SLD-3)
3567/12 SWG Stay Wire PART III (SLD-3)
3573x50+1x35 mm2 AB Cable PART III (SLD-3)
358Pole clamp for I hook PART III (SLD-3)
359Dead end clamp +I hook PART III (SLD-3)
360Danger board PART III (SLD-3)
361Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART III (SLD-3)
362Anticlimbing Device(GI barbed wire 3kg per support) PART III (SLD-3)
363Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART III (SLD-3)
364GI Nuts,Bolts & Washers PART III (SLD-3)
365Black Paint PART III (SLD-3)
366Yellow Colour Paint for Background PART III (SLD-3)
367Sundries PART III (SLD-3)
36875x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART IV (SLD-3)
369No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART IV (SLD-3)
37040mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART IV (SLD-3)
37125x6 GI flat for earthing,1.2 kg/mtr PART IV (SLD-3)
372GI nuts, bolts and washers PART IV (SLD-3)
373Eye hook for cradle guard PART IV (SLD-3)
374Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-3)
375Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-3)
376Concreting of 10 Mtr PSC Poles in ratio 1:1 5:3 = 0.415Cum. @ 6648.85 =0.415x6648.85= Rs.2759.27 PART D (SLD-3)
377Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-3)
378Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-3)
379Construction of Boundary wall boundry for fencing of DPM S/S in the size of 3x3 mtr @7300.12/RM considering height above ground level-1.65 mtr & below ground depth-1.2 mtr including the cost of fabrication, installation of MS Gate (1.5x1.65) (As per mail received from NEP dept.) PART D (SLD-3)
380Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-3)
381Survey and digitization of New DSS and its internals including attrubutes PART D (SLD-3)
3822. Dismantling worksDismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-3)
383Dismantling of 09/11 Mtr. Joist/WPB Pole- 116X100mm (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-3)
384Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-3)
385Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-3)
386Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer below 100KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-3)
387Dismantle-Steel Structure of lines & S/s PART D (SLD-3)
3889 Mtr 300 KG PSC Pole due to Road Crossing PART I (SLD-4)
3898 Mtr 200 KG PSC Pole PART I (SLD-4)
390RCC Base Plate PART I (SLD-4)
391Earthing support coil type PART I (SLD-4)
392No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-4)
393LT Stay Set complete PART I (SLD-4)
394LT Stay Insulator PART I (SLD-4)
395LT Stay clamp PART I (SLD-4)
3967/12 SWG Stay Wire PART I (SLD-4)
3971x35+1x25 mm2 LT XLPE Aerial bunched Cable PART I (SLD-4)
3983x35+1x25 mm2 LT XLPE Aerial bunched Cable PART I (SLD-4)
399Pole clamp for I hook PART I (SLD-4)
400Dead end clamp +I hook PART I (SLD-4)
401Suspension clamp with I hook PART I (SLD-4)
402Danger board PART I (SLD-4)
403Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-4)
404Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-4)
405Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-4)
406GI Nuts,Bolts & Washers PART I (SLD-4)
407Black Paint PART I (SLD-4)
408Yellow Colour Paint for Background PART I (SLD-4)
409Sundries PART I (SLD-4)
410Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-4)
411Concreting of 9mtr /8Mtr poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-4)
412Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-4)
413Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-4)
4142. Dismantling worksDismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-4)
415Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-4)
4169 Mtr long 300 KG PSC pole PART I (SLD-5)
417RCC Base Plate PART I (SLD-5)
418Earthing device Coil type (GI) PART I (SLD-5)
419No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-5)
420100x50x6 mm GI channel for straight Cross arm 1.2 mtr each 4 Nos for one Nos Cut/ tapping Point PART I (SLD-5)
42111KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART I (SLD-5)
422GI Back Clamp for 11KV \\"V \\"Cross Arm PART I (SLD-5)
42311KV pin insulator polymer PART I (SLD-5)
42411KV XLPE COVERED CONDUCTOR 55 SQMM,AAA PART I (SLD-5)
425Disc insulator (B&S)45 KN polymer PART I (SLD-5)
426Tension Assembly Wedge Type with Anchoring Clamp for 11 kV covered conductor PART I (SLD-5)
427IPC for Covered-Covered Conductor 11 KV 55 Sqmm PART I (SLD-5)
428Non-Metallic Ties 11KV(for covered conductor) PART I (SLD-5)
429Mechanical Connector with Heat Shirnk Sleeve for 11KV 55sqmm AAA Covered Conductor PART I (SLD-5)
430HT Stay Set Complete PART I (SLD-5)
431HT Stay insulator PART I (SLD-5)
432HT Stay clamp for PSC Pole (1.9Kg/pair) PART I (SLD-5)
4337/10 SWG GI Stay wire PART I (SLD-5)
434Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-5)
435Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART I (SLD-5)
436Danger Board PART I (SLD-5)
437Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-5)
438GI nuts, bolts and washers PART I (SLD-5)
439Black Paint PART I (SLD-5)
440Yellow Colour Paint for Background PART I (SLD-5)
441Sundries ( Clamp, Connectors, Binding tape etc) PART I (SLD-5)
442WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART II (SLD-5)
443Earthing Coil for support PART II (SLD-5)
444No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-5)
445Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART II (SLD-5)
446AB Switch mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART II (SLD-5)
447AB switch side support channel 100X50X6 mm,9.2 Kg/Mtr ,each channel length 0.35M,2 nos channel required PART II (SLD-5)
448Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART II (SLD-5)
449GI chanel for supporting DP arm, 75x40x6 2.8 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART II (SLD-5)
450Bracing angle (50x50x6) MM GI angle, 4.0 Mtr. long, 2Nos. (4.5kg/mtr) PART II (SLD-5)
451Disc insulator (B&S)45 KN polymer PART II (SLD-5)
452Hard ware fitting B&S Type 45KN (2Bolted) PART II (SLD-5)
453PG clamp for 55 mm2 AAA conductor PART II (SLD-5)
454Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART II (SLD-5)
45511KV pin insulator polymer PART II (SLD-5)
45611 KV AB switch 3 Pole 400Amp PART II (SLD-5)
45711 KV Lightning Arrestor 9KV 10KA PART II (SLD-5)
458HT Stay Set Complete PART II (SLD-5)
459HT Stay insulator PART II (SLD-5)
460HT Stay clamp for PSC Pole (1.9Kg/pair) PART II (SLD-5)
4617/10 SWG GI Stay wire PART II (SLD-5)
462Danger Board PART II (SLD-5)
463Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-5)
464G.I pipe Earthing 40 mm dia medium gauge (3.25mm thick ness) 3 mtr long PART II (SLD-5)
46550x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36 PART II (SLD-5)
466Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART II (SLD-5)
467Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART II (SLD-5)
468GI nuts,bolts and washers PART II (SLD-5)
469Black Paint PART II (SLD-5)
470Yellow Colour Paint for Background PART II (SLD-5)
471Sundries ( Clamp, Connectors, Binding tape etc PART II (SLD-5)
472WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART III (SLD-5)
473Earthing Coil for support PART III (SLD-5)
474No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART III (SLD-5)
475Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART III (SLD-5)
476GI chanel for supporting DP arm, 75x40x6 2.8 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART III (SLD-5)
477Bracing angle (50x50x6) MM GI angle, 4.0 Mtr. long, 2Nos. (4.5kg/mtr) PART III (SLD-5)
478Disc insulator (B&S)45 KN polymer PART III (SLD-5)
479Hard ware fitting B&S Type 45KN (2Bolted) PART III (SLD-5)
480PG clamp for 55 mm2 AAA conductor PART III (SLD-5)
481Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART III (SLD-5)
48211KV pin insulator polymer PART III (SLD-5)
483HT Stay Set Complete PART III (SLD-5)
484HT Stay insulator PART III (SLD-5)
485HT Stay clamp for PSC Pole (1.9Kg/pair) PART III (SLD-5)
4867/10 SWG GI Stay wire PART III (SLD-5)
487Danger Board PART III (SLD-5)
488Anticlimbing Device(GI barbed wire 3kg per support) PART III (SLD-5)
489G.I pipe Earthing 40 mm dia medium gauge (3.25mm thick ness) 3 mtr long PART III (SLD-5)
49050x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36 PART III (SLD-5)
491Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART III (SLD-5)
492Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART III (SLD-5)
493GI nuts,bolts and washers PART III (SLD-5)
494Black Paint PART III (SLD-5)
495Yellow Colour Paint for Background PART III (SLD-5)
496Sundries ( Clamp, Connectors, Binding tape etc PART III (SLD-5)
4979 Mtr long 300 KG PSC pole PART IV (SLD-5)
49810 Mtr long 330kg PSC pole(including transportation cost upto store) PART IV (SLD-5)
499RCC Base Plate PART IV (SLD-5)
500Earthing device Coil type (GI) PART IV (SLD-5)
501No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART IV (SLD-5)
502100x50x6 mm channel for straight Cross arm 1.2 mtr each 2 no & 0.2 mtr long 2 Nos. 01 no of Tapping Point) @ 9.2Kg/Mtr PART IV (SLD-5)
50311KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART IV (SLD-5)
504GI Back Clamp for 11KV \\"V \\"Cross Arm PART IV (SLD-5)
50511KV F Clamp 2.9 kg Each (with galvanisation) PART IV (SLD-5)
50611KV pin insulator polymer PART IV (SLD-5)
50755mm2 AAAC PART IV (SLD-5)
508Disc insulator (B&S)45 KN polymer PART IV (SLD-5)
509H W fitting (B&S)2 bolted PART IV (SLD-5)
510PG clamp for 55 mm2 AAA conductor PART IV (SLD-5)
511Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART IV (SLD-5)
512H.T.stay set ( Complete ) PART IV (SLD-5)
513H.T. Stay Insulator PART IV (SLD-5)
514H.T. Stay clamp (1.95 Kg./ Pair ) PART IV (SLD-5)
5157/10 SWG Stay Wire PART IV (SLD-5)
516Anticlimbing Device(GI barbed wire 3kg per support) PART IV (SLD-5)
517Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART IV (SLD-5)
518Danger Board PART IV (SLD-5)
519Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART IV (SLD-5)
520GI nuts, bolts and washers PART IV (SLD-5)
521Black Paint PART IV (SLD-5)
522Yellow Colour Paint for Background PART IV (SLD-5)
523Sundries ( Clamp, Connectors, Binding tape etc) PART IV (SLD-5)
52410 Mtr long 330kg PSC pole(including transportation cost upto store) PART V (SLD-5)
525RCC Base Plate PART V (SLD-5)
526Earthing device Coil type (GI) PART V (SLD-5)
527No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART V (SLD-5)
528Pressure Channel (100X50X6) mm 1.2 Mtr 2 Nos (9.2 Kg. / Mtr.) (with Galvanisation) PART V (SLD-5)
529Transformer Mounting Bracket 65x65x6 mm suitable for 16 KVA 11/0.23 KV transformer PART V (SLD-5)
530AB Switch mounting bracket (75X40X6) mm 6 Mtr (6.8 Kg. / Mtr.)(with Galvanisation) PART V (SLD-5)
531Cantilever channel for supportingAB Switch arm (50X40X6) mm angle 3.5mtr long (4.5 Kg./Mtr.)(with Galvanisation) PART V (SLD-5)
532Horn Gap Fuse mounting channel (75x40x6)mm 2.2mtr (6.8KKG/mtr)(with Galvanisation) PART V (SLD-5)
53311 KV Disc Insulator T & C Type 45 KN POLYMER PART V (SLD-5)
53411 KV hard ware fitting T & C Type 45KN PART V (SLD-5)
53511KV AB Switch 2 Pole PART V (SLD-5)
53611KV HG Fuse 2 Pole PART V (SLD-5)
5379KV 10KA Lightening Arrester PART V (SLD-5)
538H.T.stay set ( Complete ) PART V (SLD-5)
539H.T. Stay Insulator PART V (SLD-5)
540H.T. Stay clamp (1.95 K.g./ Pair ) PART V (SLD-5)
5417/10 SWG Stay Wire PART V (SLD-5)
542GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART V (SLD-5)
54325x4mm GI Flat (Neutral) PART V (SLD-5)
54425x6mm GI Flat PART V (SLD-5)
54555mm2 AAAC PART V (SLD-5)
546PG clamp for 55 mm2 AAA conductor PART V (SLD-5)
547GI Nut , Bolt & Washer PART V (SLD-5)
548LT distribution box with MCCB for 16KVA S/s PART V (SLD-5)
5492Cx16 mm2 LT PVC Cable(un armoured) PART V (SLD-5)
550Danger Board PART V (SLD-5)
551Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART V (SLD-5)
552Anticlimbing Device(GI barbed wire 3kg per support) PART V (SLD-5)
553Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART V (SLD-5)
554Black Paint PART V (SLD-5)
555Yellow Colour Paint for Background PART V (SLD-5)
556Sundries PART V (SLD-5)
5579 Mtr long 300 KG PSC pole PART VI (SLD-5)
5588 Mtr long 200 KG PSC pole PART VI (SLD-5)
559RCC Base Plate PART VI (SLD-5)
560Earthing support coil type PART VI (SLD-5)
561No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART VI (SLD-5)
562LT Stay Set complete PART VI (SLD-5)
563LT Stay Insulator PART VI (SLD-5)
564LT Stay clamp PART VI (SLD-5)
5657/12 SWG Stay Wire PART VI (SLD-5)
5661x35+1x25 mm2 AB Cable PART VI (SLD-5)
567Pole clamp for I hook PART VI (SLD-5)
568Dead end clamp +I hook PART VI (SLD-5)
569Suspension clamp with I hook PART VI (SLD-5)
570Danger board PART VI (SLD-5)
571Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART VI (SLD-5)
572Anticlimbing Device(GI barbed wire 3kg per support) PART VI (SLD-5)
573Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART VI (SLD-5)
574GI Nuts,Bolts & Washers PART VI (SLD-5)
575Black Paint PART VI (SLD-5)
576Yellow Colour Paint for Background PART VI (SLD-5)
577Sundries PART VI (SLD-5)
57875x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART VII (SLD-5)
57975x40x6 mm GI Channel Straight cross arm 3.2 mtr long 02Nos (@6.8Kg/mt) for DP road crossing guarding PART VII (SLD-5)
580No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART VII (SLD-5)
58140mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART VII (SLD-5)
58225x6 GI flat for earthing,1.2 kg/mtr PART VII (SLD-5)
583GI nuts, bolts and washers PART VII (SLD-5)
584Eye hook for cradle guard PART VII (SLD-5)
585Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-5)
586Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-5)
587Concreting of 10 Mtr PSC Poles in ratio 1:1 5:3 = 0.415Cum. @ 6648.85 =0.415x6648.85= Rs.2759.27 PART D (SLD-5)
588Concreting of 9mtr /8Mtr poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-5)
589Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-5)
590Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-5)
591Supply and Erection of GI Fencing with Gate as per standard specifications . Providing and fixing galvanized steel chain link fencing with 75*75 mm mesh size, 4.00 mm dia mesh wire conforming to IS:2721, GI stirrups wire 2.5 mm dia with tying wire 6 mm dia mild GI steel including providing 25 mm x 4.75 mm GI stretcher bars, eye bolt strainers, ring nuts, hair pins, staples of 3.5 mm wire, cleats of GI angle 75 x 60 x 6 mm, MS droppers 25 mm x 4.75 mm with 38 mm x 4.85 mm half round staples PART D (SLD-5)
592Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-5)
593Survey and digitization of New DSS and its internals including attrubutes PART D (SLD-5)
594Dismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-5)
595Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-5)
596Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-5)
597Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 16KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-5)
598Dismantle-Steel Structure of lines & S/s PART D (SLD-5)
599Dismantling of 11 kV /33KV GO/AB Switch/Isolator/DD fuse/fuse set including removal of all Electric/Earth connections, loading, transportation, unloading and staking at a proper place in safe position/BA site store(Note Set =Three phase). PART D (SLD-5)
600WPB 160x152 (13Mtr. Long, 30.44KG/Mtr.) PART I (SLD-6)
601Earthing of Support ( Coil Type ) PART I (SLD-6)
602No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-6)
603Top Channel 100X50X6mm, 9.2 KG/Mtr., each channel length 3.5 mtr., 2 no's channel required =( 2x9.2x3.5) PART I (SLD-6)
604Double Pole Belting Channel 75X40X 6mm., 6.8KG/Mtr., each channel length 3.5 Mtr., 4 no's channel required =( 4x6.8x3.5) PART I (SLD-6)
60550x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 5.5 mtr., 2 nos angle required = (2*4.5*5.5) PART I (SLD-6)
606Fish Plate 50X8 mm., 3.14kg/Mtr., each 0.280 mtr. Length PART I (SLD-6)
607GI Nut , Bolt & Washer of different sizes PART I (SLD-6)
608Danger Plate PART I (SLD-6)
609Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART I (SLD-6)
610GI barbed wire anticlimbing device PART I (SLD-6)
611Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4no's = (4x0.59x0.510) PART I (SLD-6)
612148mm² All Alloy Aluminium Conductor-AAAC PART I (SLD-6)
61333KV pin insulator polymer PART I (SLD-6)
614H W fitting(B&S) 120 KN,4 Bolt PART I (SLD-6)
615Disc insulator (B&S) 120 KN polymer PART I (SLD-6)
616PG Clamp for 148 sq.mm AAA conductor PART I (SLD-6)
617H.T. Stay clamp PART I (SLD-6)
618H.T. Stay set (Complete ) PART I (SLD-6)
619H.T. Stay Insulator PART I (SLD-6)
6207/8 SWG Stay Wire PART I (SLD-6)
621Lightning Arrester (30KV,10KA) (Station Class, class- 2) PART I (SLD-6)
62240mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART I (SLD-6)
62325x6 GI flat for earthing PART I (SLD-6)
624Black Paint PART I (SLD-6)
625Yellow Colour Paint for Background PART I (SLD-6)
626Sundries (Paint, Clamp, Connectors, Binding tape etc PART I (SLD-6)
627WPB 160x152 (30.44KG/Mtr.),13 mtr- with base plate 300x300x12 PART II (SLD-6)
628Earthing of Support ( Coil Type ) PART II (SLD-6)
629No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-6)
63033 KV V cross Arm (GI) 22Kg each PART II (SLD-6)
631Top bracket 100x50x6mm GI channel (2kg each) PART II (SLD-6)
632GI Back Clamp for 33kV 'V' Cros Arm PART II (SLD-6)
63333KV pin insulator polymer PART II (SLD-6)
634GI nuts, bolts and washers PART II (SLD-6)
635Danger Board PART II (SLD-6)
636Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART II (SLD-6)
637GI barbed wire anticlimbing device PART II (SLD-6)
638Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART II (SLD-6)
639Black Paint PART II (SLD-6)
640Yellow Colour Paint for Background PART II (SLD-6)
641Sundries PART II (SLD-6)
642WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART III (SLD-6)
643Earthing Coil for support PART III (SLD-6)
644No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART III (SLD-6)
645100x50x6 mm channel for straight Cross arm 1.2 mtr each 4 no & 0.2 mtr long 4 No. ( 4cut point) @ 9.2Kg/Mtr PART III (SLD-6)
64611KV pin insulator polymer PART III (SLD-6)
64755mm2 AAAC PART III (SLD-6)
648Disc insulator (B&S)45 KN polymer PART III (SLD-6)
649H W fitting (B&S)2 bolted PART III (SLD-6)
650PG clamp for 55 mm2 AAA conductor PART III (SLD-6)
651Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART III (SLD-6)
652H.T.stay set ( Complete ) PART III (SLD-6)
653H.T. Stay Insulator PART III (SLD-6)
654H.T. Stay clamp (1.95 Kg./ Pair ) PART III (SLD-6)
6557/10 SWG Stay Wire PART III (SLD-6)
656Anticlimbing Device(GI barbed wire 3kg per support) PART III (SLD-6)
657Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART III (SLD-6)
658Danger Board PART III (SLD-6)
659Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART III (SLD-6)
660GI nuts, bolts and washers PART III (SLD-6)
661Black Paint PART III (SLD-6)
662Yellow Colour Paint for Background PART III (SLD-6)
663Sundries ( Clamp, Connectors, Binding tape etc) PART III (SLD-6)
6649 Mtr long 300 KG PSC pole PART IV (SLD-6)
6658 Mtr long 200 KG PSC pole PART IV (SLD-6)
666RCC Base Plate PART IV (SLD-6)
667Earthing support coil type PART IV (SLD-6)
668No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART IV (SLD-6)
669LT Stay Set complete PART IV (SLD-6)
670LT Stay Insulator PART IV (SLD-6)
671LT Stay clamp PART IV (SLD-6)
6727/12 SWG Stay Wire PART IV (SLD-6)
6733x35+1x25 mm2 LT XLPE Aerial bunched Cable PART IV (SLD-6)
674Pole clamp for I hook PART IV (SLD-6)
675Dead end clamp +I hook PART IV (SLD-6)
676Suspension clamp with I hook PART IV (SLD-6)
677Danger board PART IV (SLD-6)
678Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART IV (SLD-6)
679Anticlimbing Device(GI barbed wire 3kg per support) PART IV (SLD-6)
680Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART IV (SLD-6)
681GI Nuts,Bolts & Washers PART IV (SLD-6)
682Black Paint PART IV (SLD-6)
683Yellow Colour Paint for Background PART IV (SLD-6)
684Sundries PART IV (SLD-6)
68575x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART V (SLD-6)
686No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART V (SLD-6)
68740mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART V (SLD-6)
68825x6 GI flat for earthing,1.2 kg/mtr PART V (SLD-6)
689GI nuts, bolts and washers PART V (SLD-6)
690Eye hook for cradle guard PART V (SLD-6)
691Guarding cross arm of 75x40x6mm GI Channel 3.5 mtr long 4Nos @6.8Kg/mtr PART VI (SLD-6)
692No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART VI (SLD-6)
69340mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART VI (SLD-6)
69425x6 GI flat for earthing,1.2 kg/mtr PART VI (SLD-6)
695GI nuts, bolts and washers PART VI (SLD-6)
696Eye hook for cradle guard PART VI (SLD-6)
697Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-6)
698Concreting of 13Mtr. poles in ratio 1:1.5:3 =0.55 cum. @ 6648.85=0.55 x 6648.85=Rs. 3656.87 PART D (SLD-6)
699Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-6)
700Concreting of 9mtr /8Mtr poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-6)
701Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-6)
702Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-6)
703Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-6)
704Dismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-6)
705Dismantling of 09/11 Mtr. Joist/WPB Pole- 116X100mm (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-6)
706Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-6)
707Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-6)
708Dismantling of ACSR/AAAC 80/100/148mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-6)
709Dismantle-Steel Structure of lines & S/s PART D (SLD-6)
710WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART I (SLD-7)
711Earthing Coil for support PART I (SLD-7)
712No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-7)
713100x50x6 mm channel for straight Cross arm 1.2 mtr each 4 no & 0.2 mtr long 4 No. ( 4cut point) @ 9.2Kg/Mtr PART I (SLD-7)
71411KV pin insulator polymer PART I (SLD-7)
71555mm2 AAAC PART I (SLD-7)
716Disc insulator (B&S)45 KN polymer PART I (SLD-7)
717H W fitting (B&S)2 bolted PART I (SLD-7)
718PG clamp for 55 mm2 AAA conductor PART I (SLD-7)
719Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART I (SLD-7)
720H.T.stay set ( Complete ) PART I (SLD-7)
721H.T. Stay Insulator PART I (SLD-7)
722H.T. Stay clamp (1.95 Kg./ Pair ) PART I (SLD-7)
7237/10 SWG Stay Wire PART I (SLD-7)
724Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-7)
725Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART I (SLD-7)
726Danger Board PART I (SLD-7)
727Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-7)
728GI nuts, bolts and washers PART I (SLD-7)
729Black Paint PART I (SLD-7)
730Yellow Colour Paint for Background PART I (SLD-7)
731Sundries ( Clamp, Connectors, Binding tape etc) PART I (SLD-7)
73275x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART II (SLD-7)
733No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART II (SLD-7)
73440mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART II (SLD-7)
73525x6 GI flat for earthing,1.2 kg/mtr PART II (SLD-7)
736GI nuts, bolts and washers PART II (SLD-7)
737Eye hook for cradle guard PART II (SLD-7)
738Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-7)
739Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-7)
740Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-7)
741Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-7)
742Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-7)
7432. Dismantling worksDismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-7)
744Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-7)
745Dismantle-Steel Structure of lines & S/s PART D (SLD-7)
746300 Kg., 9 Mtr. long PSC pole PART I (SLD-8)
747RCC Base Plate PART I (SLD-8)
748Earthing device Coil type (GI) PART I (SLD-8)
749No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-8)
750Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART I (SLD-8)
751Transformer mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART I (SLD-8)
752AB Swith & HG Fuse, Mounting GI Channel 75x40x6 - 2.8 mtr.long, 4 nos.(@6.8K.g/mtr) PART I (SLD-8)
753Cantilever GI chanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART I (SLD-8)
754Cantilever Angel for supporting AB switch 50x50x6 mm GI Angel (1.0mtr Long 2Nos.) (@4.5K.g/mtr) PART I (SLD-8)
755Transformer belting GI Angel 50x50x6mm - 2.8mtr Long 2nos. (@4.5K.g/mtr) with side angel (Total 7mtr.) PART I (SLD-8)
756Angle for mounting LT distribution Box 50x50x 6mm GI Angel -1mtrs.each Long 2Nos.( @4.5K.g/mtr) PART I (SLD-8)
757AB Switch Side Support Channel 100X50X6mm,9.2KG/Mtr., each channel length 0.35 mtr., 2 no's channel required PART I (SLD-8)
758Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART I (SLD-8)
75911KV Disc Insulator B&S Type 45KN Ploymer PART I (SLD-8)
760Hard ware fitting B&S Type 45KN (2Bolted) PART I (SLD-8)
76111KV AB Switch 3 Pole (200 Amp) PART I (SLD-8)
76211KV HG Fuse 3 Pole (200 Amp) PART I (SLD-8)
763Lightning arrester (9KV, 5Ka) PART I (SLD-8)
764H.T.stay set ( Complete ) PART I (SLD-8)
765H.T. Stay Insulator PART I (SLD-8)
766H.T. Stay clamp (1.95 K.g./ Pair ) PART I (SLD-8)
7677/10 SWG Stay Wire PART I (SLD-8)
768GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART I (SLD-8)
76925x4mm GI Flat (Neutral) PART I (SLD-8)
77025x6mm GI Flat PART I (SLD-8)
77155mm2 AAAC PART I (SLD-8)
772PG clamp for 55 mm2 AAA conductor PART I (SLD-8)
773GI Nut , Bolt & Washer PART I (SLD-8)
774LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S PART I (SLD-8)
7751Cx70 mm2 LT,XLPE Cable(Un- armoured) 4nos 10mtr each PART I (SLD-8)
776Danger Board PART I (SLD-8)
777Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART I (SLD-8)
778Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-8)
779Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART I (SLD-8)
780Black Paint PART I (SLD-8)
781Yellow Colour Paint for Background PART I (SLD-8)
782Sundries (Almunium binding tape, Insulating tape, Binding Tape Allm. Cable Socket etc. ) PART I (SLD-8)
7839 Mtr long 300 KG PSC pole PART II (SLD-8)
784RCC Base Plate PART II (SLD-8)
785Earthing Coil for support PART II (SLD-8)
786No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-8)
787100x50x6 mm channel for straight Cross arm 1.2 mtr each 4 no & 0.2 mtr long 4 No. ( 1cut point) @ 9.2Kg/Mtr PART II (SLD-8)
78811KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART II (SLD-8)
789GI Back Clamp for 11KV \\"V \\"Cross Arm PART II (SLD-8)
79011KV F Clamp 2.9 kg Each (with galvanisation) PART II (SLD-8)
79111KV pin insulator polymer PART II (SLD-8)
79255mm2 AAAC PART II (SLD-8)
793Disc insulator (B&S)45 KN polymer PART II (SLD-8)
794H W fitting (B&S)2 bolted PART II (SLD-8)
795PG clamp for 55 mm2 AAA conductor PART II (SLD-8)
796Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART II (SLD-8)
797H.T.stay set ( Complete ) PART II (SLD-8)
798H.T. Stay Insulator PART II (SLD-8)
799H.T. Stay clamp (1.95 Kg./ Pair ) PART II (SLD-8)
8007/10 SWG Stay Wire PART II (SLD-8)
801Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-8)
802Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART II (SLD-8)
803Danger Board PART II (SLD-8)
804Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-8)
805GI nuts, bolts and washers PART II (SLD-8)
806Black Paint PART II (SLD-8)
807Yellow Colour Paint for Background PART II (SLD-8)
808Sundries ( Clamp, Connectors, Binding tape etc) PART II (SLD-8)
80975x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART III (SLD-8)
810No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART III (SLD-8)
81140mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART III (SLD-8)
81225x6 GI flat for earthing,1.2 kg/mtr PART III (SLD-8)
813GI nuts, bolts and washers PART III (SLD-8)
814Eye hook for cradle guard PART III (SLD-8)
815Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-8)
816Concreting of 9mtr PSC poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-8)
817Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-8)
818Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-8)
819Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-8)
820Survey and digitization of New DSS and its internals including attrubutes PART D (SLD-8)
821Dismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-8)
822Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-8)
823Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 25KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-8)
824Dismantle-Steel Structure of lines & S/s PART D (SLD-8)
825300 Kg., 9 Mtr. long PSC pole PART I (SLD-9)
826RCC Base Plate PART I (SLD-9)
827Earthing device Coil type (GI) PART I (SLD-9)
828No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-9)
829Top Pressure GI Channel 100x50 x6mm each 2.8mtr. Long, 2Nos ( @9.2K.g/mtr.) PART I (SLD-9)
830Transformer mounting GI chhanel 100x50x6mm channel each 2.8mtr. Long 2Nos (@9.2Kg/mtr) PART I (SLD-9)
831AB Swith & HG Fuse, Mounting GI Channel 75x40x6 - 2.8 mtr.long, 4 nos.(@6.8K.g/mtr) PART I (SLD-9)
832Cantilever GI chanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.) PART I (SLD-9)
833Cantilever Angel for supporting AB switch 50x50x6 mm GI Angel (1.0mtr Long 2Nos.) (@4.5K.g/mtr) PART I (SLD-9)
834Transformer belting GI Angel 50x50x6mm - 2.8mtr Long 2nos. (@4.5K.g/mtr) with side angel (Total 7mtr.) PART I (SLD-9)
835Angle for mounting LT distribution Box 50x50x 6mm GI Angel -1mtrs.each Long 2Nos.( @4.5K.g/mtr) PART I (SLD-9)
836AB Switch Side Support Channel 100X50X6mm,9.2KG/Mtr., each channel length 0.35 mtr., 2 no's channel required PART I (SLD-9)
837Channel Support for down Pipe 75X40X6mm., 6.8KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required PART I (SLD-9)
83811KV Disc Insulator B&S Type 45KN Ploymer PART I (SLD-9)
839Hard ware fitting B&S Type 45KN (2Bolted) PART I (SLD-9)
84011KV AB Switch 3 Pole (200 Amp) PART I (SLD-9)
84111KV HG Fuse 3 Pole (200 Amp) PART I (SLD-9)
842Lightning arrester (9KV, 5Ka) PART I (SLD-9)
843H.T.stay set ( Complete ) PART I (SLD-9)
844H.T. Stay Insulator PART I (SLD-9)
845H.T. Stay clamp (1.95 K.g./ Pair ) PART I (SLD-9)
8467/10 SWG Stay Wire PART I (SLD-9)
847GI Pipe Earthing 40mm Dia Medium gauge 3 mtrs. Long PART I (SLD-9)
84825x4mm GI Flat (Neutral) PART I (SLD-9)
84925x6mm GI Flat PART I (SLD-9)
85055mm2 AAAC PART I (SLD-9)
851PG clamp for 55 mm2 AAA conductor PART I (SLD-9)
852GI Nut , Bolt & Washer PART I (SLD-9)
853LT Distribution Box with MCCB, Aluminium Busbar of single Bay with kit kat fuse for 25 KVA S/S PART I (SLD-9)
8541Cx70 mm2 LT,XLPE Cable(Un- armoured) 4nos 10mtr each PART I (SLD-9)
855Danger Board PART I (SLD-9)
856Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no PART I (SLD-9)
857Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-9)
858Back Clamp for Barbed wire anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's PART I (SLD-9)
859Black Paint PART I (SLD-9)
860Yellow Colour Paint for Background PART I (SLD-9)
861Sundries (Almunium binding tape, Insulating tape, Binding Tape Allm. Cable Socket etc. ) PART I (SLD-9)
8629 Mtr 300 KG PSC Pole due to Road Crossing PART II (SLD-9)
8638 Mtr 200 KG PSC Pole PART II (SLD-9)
864RCC Base Plate PART II (SLD-9)
865Earthing support coil type PART II (SLD-9)
866No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-9)
867LT Stay Set complete PART II (SLD-9)
868LT Stay Insulator PART II (SLD-9)
869LT Stay clamp PART II (SLD-9)
8707/12 SWG Stay Wire PART II (SLD-9)
8711x35+1x25 mm2 LT XLPE Aerial bunched Cable PART II (SLD-9)
8723x35+1x25 mm2 LT XLPE Aerial bunched Cable PART II (SLD-9)
873Pole clamp for I hook PART II (SLD-9)
874Dead end clamp +I hook PART II (SLD-9)
875Suspension clamp with I hook PART II (SLD-9)
876Danger board PART II (SLD-9)
877Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-9)
878Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-9)
879Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-9)
880GI Nuts,Bolts & Washers PART II (SLD-9)
881Black Paint PART II (SLD-9)
882Yellow Colour Paint for Background PART II (SLD-9)
883Sundries PART II (SLD-9)
884Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-9)
885Concreting of 9mtr PSC poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-9)
886Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-9)
887Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-9)
888Construction of Boundary wall boundry for fencing of DPM S/S in the size of 3x3 mtr @7300.12/RM considering height above ground level-1.65 mtr & below ground depth-1.2 mtr including the cost of fabrication, installation of MS Gate (1.5x1.65) (As per mail received from NEP dept.) PART D (SLD-9)
889Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-9)
8902. Dismantling worksDismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-9)
891Dismantling of existing 11/0.4kV, 33/0.4KV, Three Phase Distribution Transformer 25KVA including removal of HT/LT leads, earth connections and unloading by crane if required. Scope of work also includes loading, transportation, unloading and staking at a proper place in safe position/site store PART D (SLD-9)
892Dismantle-Steel Structure of lines & S/s PART D (SLD-9)
893Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-9)
894WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12 PART I (SLD-10)
895Earthing Coil for support PART I (SLD-10)
896No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART I (SLD-10)
897100x50x6 mm channel for straight Cross arm 1.2 mtr each 4 no & 0.2 mtr long 4 No. ( 1cut point) @ 9.2Kg/Mtr PART I (SLD-10)
89811KV 'V' Cross Arm 10.2kg Each (with galvanisation) PART I (SLD-10)
899GI Back Clamp for 11KV \\"V \\"Cross Arm PART I (SLD-10)
90011KV F Clamp 2.9 kg Each (with galvanisation) PART I (SLD-10)
90111KV pin insulator polymer PART I (SLD-10)
90255mm2 AAAC PART I (SLD-10)
903Disc insulator (B&S)45 KN polymer PART I (SLD-10)
904H W fitting (B&S)2 bolted PART I (SLD-10)
905PG clamp for 55 mm2 AAA conductor PART I (SLD-10)
906Fish Plate 50X8 mm,3.14 Kg./Mtr,each 0.280 mtr. Length PART I (SLD-10)
907H.T.stay set ( Complete ) PART I (SLD-10)
908H.T. Stay Insulator PART I (SLD-10)
909H.T. Stay clamp (1.95 Kg./ Pair ) PART I (SLD-10)
9107/10 SWG Stay Wire PART I (SLD-10)
911Anticlimbing Device(GI barbed wire 3kg per support) PART I (SLD-10)
912Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp(4pc/support). PART I (SLD-10)
913Danger Board PART I (SLD-10)
914Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART I (SLD-10)
915GI nuts, bolts and washers PART I (SLD-10)
916Black Paint PART I (SLD-10)
917Yellow Colour Paint for Background PART I (SLD-10)
918Sundries ( Clamp, Connectors, Binding tape etc) PART I (SLD-10)
9199 Mtr 300 KG PSC Pole due to Road Crossing PART II (SLD-10)
9208 Mtr 200 KG PSC Pole PART II (SLD-10)
921RCC Base Plate PART II (SLD-10)
922Earthing support coil type PART II (SLD-10)
923No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing PART II (SLD-10)
924LT Stay Set complete PART II (SLD-10)
925LT Stay Insulator PART II (SLD-10)
926LT Stay clamp PART II (SLD-10)
9277/12 SWG Stay Wire PART II (SLD-10)
9281x35+1x25 mm2 LT XLPE Aerial bunched Cable PART II (SLD-10)
929Pole clamp for I hook PART II (SLD-10)
930Dead end clamp +I hook PART II (SLD-10)
931Suspension clamp with I hook PART II (SLD-10)
932Danger board PART II (SLD-10)
933Back Clamp for Danger Board (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-10)
934Anticlimbing Device(GI barbed wire 3kg per support) PART II (SLD-10)
935Back Clamp for ACD (25X3mm GI Earth Flat ,0.59Kg/Mtr & 0.51Mtr for Each Back Clamp. PART II (SLD-10)
936GI Nuts,Bolts & Washers PART II (SLD-10)
937Black Paint PART II (SLD-10)
938Yellow Colour Paint for Background PART II (SLD-10)
939Sundries PART II (SLD-10)
94075x40x6 mm GI Channel Straight cross arm 1.5mtr long 04Nos (@6.8Kg/mt)for road crossing guarding PART III (SLD-10)
941No-6, No-8, No. 10 GI wire ( Dia 4.8mm) for Guadring PART III (SLD-10)
94240mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long PART III (SLD-10)
94325x6 GI flat for earthing,1.2 kg/mtr PART III (SLD-10)
944GI nuts, bolts and washers PART III (SLD-10)
945Eye hook for cradle guard PART III (SLD-10)
946Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum. @6500 PART D (SLD-10)
947Concreting of 11Mtr WPB Poles in ratio 1:1 5:3 = 0.45Cum. @6648.85 =0.45x6648.85= Rs.2991.98 PART D (SLD-10)
948Concreting of 9mtr PSC poles in ratio 1:1 5:3 = 0.375Cum. @ 6648.85 =0.375x6648.85= Rs.2493.32 PART D (SLD-10)
949Couping of poles in ratio 1:1.5:3 0.1125Cum. @6648.85= 0.1125x6648.85= Rs.748.00 PART D (SLD-10)
950Materials for Massionary work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2\\"x2\\") and RCC slab cover PART D (SLD-10)
951Survey of incremental/delta network and assets changes of 11 kV & LT network and updation in GESW databas PART D (SLD-10)
952Dismantling of 9/8 Mtr. PCC/Joist Pole (Serviceable Pole) after digging the pit and taking out the pole, transportation and stacking the pole at a proper place in safe position within 10km /site store and refilling the pit with loose earth and ramming including removal and disposal of malba at proper location as per instruction of EIC. PART D (SLD-10)
953Dismantling of ACSR/AAAC 34/ 55mm2 from overhead line, recoiling, loading, transportation, unloading and staking at a proper place in safe position/ site store PART D (SLD-10)
954Dismantle-Steel Structure of lines & S/s PART D (SLD-10)
955Dismantling of varous size of LT AB Cable from over head line, recoiling, loading,transportation, unloading and staking at a proper place in safe position/BA site store. PART D (SLD-10)N:B: Salvage Value to be deducted from the contractor's Bill. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58466395
AUTHORITY Government Departments
TENDER VALUE 82.94 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Shifting Of Electrical Infrastructure For The Work Improvement Such As Widening & Strengthening Of Sanabutupali-Panthei Road From 0/000 Km To 14/900 Km In The District Of Boudh Under State Plan.
Basic Detail
Tender No Bid Identification No.S.E.E.C (RandB) 39/2026-27
Bidding Type Tender
Location
City Boudh
State Odisha
Key Dates
Publish Date 09 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 82.94 Lakhs
Tender Fee 10000
EMD 82947
Exemption Not Available
Document List
BOQ_619610.xls
c243d340-0c2a-41cb-8a01-c70b00d5dc6a.html
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_619610.xls

html

c243d340-0c2a-41cb-8a01-c70b00d5dc6a.html

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender