Tender For B.O.Q For Installation Of High Mast Lights At Gcope Ganderbal
Tender Value
2.63 Crore
Estimated cost
Bid Submission
18 Nov 2026
4 days left
EMD
5.26 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Installation Of High Mast Lights At Gcope Ganderbal
BOQ
| Sl. No. | Item Description |
| 1 | Part A: Athletics |
| 2 | Designing, Supply, Installation, testing & commissioning of 25-28m Hot dip galvanised, polygonal high masts with fixed head frame/cross arms suitable for mounting up to 48 nos. of LED Flood Light complete with all accessories as per specification. The lights shall be mounted on top surface of each crossarm only. Hanging type mounting of LED lights is to be avoided. Each mast shaft section shall have only one longitudinal weld except the bottom section with max 2 welds and without any circumferential weld joint. Sections with more than one longitudinal weld shall not be accepted. The height of the mast from base to TOP of head frame shall be minimum 25 mtrs in 3 sections [High mast shaft in two sections with suitable length having minimum thickness 8 mm. (bottom section) and suitable length (Top section) minimum thickness 6 mm and Head frame section of length 5 to 6 mtr. minimum thickness 5 mm. 20 polygonal sided having diameter not less than 850 mm at bottom, 350 mm at top of the mast, for head frame section the Dia mtr. shall be minimum 350 mm both at bottom and top. The Dia mtr. of baseplate shall be minimum 1110 mm and thickness shall be minimum 40mm.the mast shall include the necessary mechanism for complete operation of man rider unit including gears and motor of suitable capacity. The mast shaft shall be manufactured from high tensile steel plates confirming to BS EN 10025 having minimum yield strength of 355N/Sq. mm. Hight mast OEM should have been NABL certification for high mast structure material or should have a valid certification of ISO 9001. The pole shall includea) foundation bolts design of suitable length, b) Supplying, installation, testing and commissioning of CAJB. Mast pole with necessary controlling incoming and outgoing switchgears for motor for lifting and lowering main rider unit, cabling for sports light fittings from sports light fittings to controlling switchgears control, aviation light control complete including connection etc. as required.c) Earthing of structure as per the relevant IS standardsd)75mm Dia DWC/PVC/GI- pipe for cable entry Note1: The firm shall provide structural and foundation design ( including SBC tests, wind load (up to 170 kmph) and snow load calculation sheet, Structural stability certificate, foundation design and Anchor bolt design referring to IS 875 part 3 and IS 800), the design shall confirm to structural stability in seismic zone 5, which is to be vetted by institutions like NIT /IIT for which nothing extra shall be paid. (Approved Sports Light High mast / Pole makes: BAJAJ / VALMOUNT/ TRANSRAIL/RR Ispat (Consoul)/Utkarsh) or equivalentNote2: The agency should obtain and submit to department, 25 years warranty certificate of high mast structure. Note3: Design shall be based IS:1875(Part IIII):1987, S:800:2007, BS EN 10025 S355/JISG3101 SS400, BS 5135, IS:5986, IS:4759, IS:2629, IS:2062 , ISO 1461 and other reference code as decided by Engineer-in-charge |
| 3 | Supply Assembly testing and commisiioning of Manrider the mast should have comprehensive arrangement of motorized climbing mechanism manrider cage unit for accessing the head frame for repai/ maintenance purpose with all safety arrangements like free fall arrester/ overload protection etc. the mobile manrider which shall be common to all for masts with a minimus safe load carrying capacity of 300Kgs and sufficient space for carrying 2 persons with tools and at lest 1 LED LIght the operational requirement are as follows climbing speed sh >=7m/min, voltage rating 3Phase 400V, 50Hz AC motorCapacity > 300Kgs Note (these two manriders are mobile equipment and are common for all four masts |
| 4 | Consultancy for soil investigation (Geo-technical) report b.w.o Determination of geo technical investigation/safe bearing capacity by means of boreholes/open pits including mechanical boring where required and prepration of test reports as per IS 2131-1981 up to 10.00 m depth or refusal and collection of disturbed soil samples at 1.5 m interval, laboratory testing as per IS 2720 (sieve analysis, Atterberg limits, density, moisture content, shear strength and other parameters as direcyted bu EIC), settlement consideration and submission of detailed geo technical investigation report in duplicate complete as per directions of Engineer-in-Charge. |
| 5 | Design, Supply of required material and Casting of RCC Foundation for 25-28 Mtr Stadium High Mast suitable for Soil Bearing capacity as subjected to the soil conditions for the 28 Mtr High Mast with specification above. The foundation has to be as per OEM desingn and safe soil bearing capacity report. The foundation shall be designed for wind pressure, earth quake as detailed in specification of the mast as per latest IS code of practice. The Job includes Excavation work & Malba/ Debris etc. generated while carrying out civil work will be dumped with in the premises of the stadium at a distance of maximum 200 Mtr. The Drawing should be approved by the OEM and vetted from institutions like NIT /IIT. The Job shall be lookover and verified by Civil Division Ganderbal. |
| 6 | Supply, Installation, testing & commissioning of high-quality integrated LED Flood Light with a minimum system lumen of 66000lm and system wattage of minimum 470W (±2W) with a nominal system efficacy ≥140 lumen/watt. The luminaire shall deliver minimum system lumen output of 67600lm at offered wattage. The housing should be of non-corrosive high-pressure single piece pressure die-cast aluminium to withstand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF ≥ 0.95. Lifetime of 75K hours @L70 at 35deg C ambient temperature. Product should be suitable for continuous operation (10-12 Hrs. per day). The luminaire shall be IP66 & IK10 compliant. Driver/SPD shall be maintainable/replaceable without accessing the LED compartment. The luminaire shall employ potted drivers. The potting shall be done with compound of asphalt & silica. The input voltage range for driver shall be 120-277V AC. The luminaire shall be powered using dimmable driver having THD≤10% (@full load), PF ≥ 0.95 (@full load), In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The driver shall be EMI/EMC Complied as per EN55015/CISPR15. The Luminaire should have a 20 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 20KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire must have a breather. The luminaire should be of Class B Serviceability. The LEDs used shall be SMD type & Ceramic Base High Power LEDs (COB type LED chip is not acceptable. MultiChip LED arrays is not acceptable), Individual LED wattage shall be ≥1W & ≤ 3W. The LED efficacy shall be ≥ 140lumens/watt (at design operating current and Tj: 85deg C.), CCT: 5700°K, CRI≥70 & SDCM ≤ 5. The luminaire shall have option for minimum three beam angles wiz FLNB beam (Horizontal Beam Angle-81.5 & Vertical Beam Angle- 23.4), asymmetric wide beam (Horizontal Beam Angle-58.5, Vertical Beam Angle-17.7) & narrow beam (Horizontal Beam Angle-11.7, Vertical Beam Angle-12.7). The bidder shall select the beam angles as per site requirements. The Luminaire life shall be 50000 Hrs @ Ta35°C. It shall operate at an operating temperature range of -10°C up to +35°C. The luminaire driver & it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer within 15 days of award of LOI. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approval: LM79 as per 2019 standard issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, IK Test report for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. The job further includes replacement warranty of fixture from OEM (if damaged/burnt out what so ever reason) for a period of three years reckoned from date of successful commissioning /handing over of site to intending department. connection wires Philips/Wipro/LT /Regent /Endo or equivalent Make as approved by Deptt.NOTE: any better design shall be accepted & approved after prior approval from EIC without changes in key specifications of the luminaries |
| 7 | Supply ,Installation, testing and commissioning of IP 65 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather.Incoming: 160 Amp-4 pole,36kA,TPN MCCB L&T/ABB/Legrand/Simens Make = 01 No. 2CONT 160 A4P,415V 1 NO WITH ASTRONOMOCAL TIMER , AUTO MANUAL SWTCH &NECESSARY COMPONENTS & 200 Amp Suitable Al. Bus bar = 01 Set,Indicator(Solid State Type) = 01 Set Outgoing:1) 55 No. 16A SPN MCB2) 02 No. 6A SPN ( Aviation Light)3) 01No. 32A SPN (Man-Rider)4) 1 No. Contactor 16A 4P5) 1 No. Thermal Overload Relay including 2 NO/ NC & NO/NC6) Push Button for Lowering/Raising of Frame of Mast Lights(Auto-Manual) |
| 8 | Main Panel |
| 9 | supply ,Installation, testing and commissioning of IP 65 cubicle type High mast Lighting Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather. drawing to be approved fron EIC |
| 10 | INCOMER:- |
| 11 | 1 No. 150A, TPN MCCB (55kA) with thermo magnetic releases and all required accessories. |
| 12 | 1 Set phase indication lights (R, Y, B) Solid state type (LED) |
| 13 | 1 No. 0 to 500V, AC, Volt Meter with VSS & control fuses. |
| 14 | 1 No. 0 to 200A, Ammeter with ASS &CT's. of ratio 200/5A and class-1 accuracy. |
| 15 | Outgoing |
| 16 | 4 Nos.+1 spare 63A TPN MCCB (15kA) with thermo-magnetic releases. |
| 17 | Cables |
| 18 | Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper/Al conductor, PVC inner sheathed, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. |
| 19 | Supply and lying 3CX 4sqmm unarmoured CU cable |
| 20 | Supply and lying 3.5CX 120sqmm Armoured AL cable |
| 21 | Conduit |
| 22 | SITC of 25 MM MS flexibale conduit |
| 23 | Supplying and making end termination with brass compression gland copper lugs for following size of FRLS XLPE insulated and PVC sheathed copper conductor cable of 1.1 KV grade as required: |
| 24 | 3C X 4 Sq.mm. unarmoured copper |
| 25 | 3.5Cx 120 Sqmm Aluminum armoured cable (CONSIDERED 400 METER LENGTH) |
| 26 | Termination with |
| 27 | 3CX 2.5sqmm unarmoured CU cable |
| 28 | 3.5CX 120sqmm armoured AL cable |
| 29 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.(For Poles/Panels) |
| 30 | Providing and fixing 25 mm X 3 mm Copper strip from earth electrode, as required. |
| 31 | SITC of HDPE pipe 100mm dia |
| 32 | Supply/Fixing/Testing and Commissioning of 6 Amp to 10 Amp Rating ,240v,*C* Curve 10K,SP Miniature Circuit Breaker suitable for inductive load and to be fitted in existing poles Complete with connections.(L&T/Siemens/ Legrand/ABB /Havells/BCH Make) |
| 33 | Supply/Laying/Testing and Commissioning of following Al armored XLPE Insulated,PVC cable Havells/Polycab/RR-Kabel/KEI /Apar Make. Including Supply/Laying of HDPE Pipe of required size, ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01 Ft below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. |
| 34 | 4-Core 10 mm sq. |
| 35 | 4-Core 16 mm sq. |
| 36 | Providing of service connection to be carried from pole junction box to luminaries using 3-Core 1.5 Sq.mm FR-LSH multistrend copper wire(Flat Cable) confirming IS 694 ammended upto date of Havells/Polycab/RR-Kabel/KEI /Apar Make |
| 37 | Providing of service connection to be carried from pole junction box to luminaries using 3-Core 2.5 Sq.mm FR-LSH multistrend copper wire(Flat Cable) confirming IS 694 ammended upto date of Havells/Polycab/Salzer/Finolex/ KEI Make. |
| 38 | Supply, Erection, Testing & commissioning of 11 Meter octagonal Poles along with ring for holding upto 4 No. of flood lights of Valmount/Bajaj/Surya Make |
| 39 | Foundation work of 11 Meter Octagonal Pole as per approved drawing & as per instructions of EIC |
| 40 | Part-C (Main Power Supply & Sub-Station along with HT Network) |
| 41 | Supply/Laying/Testing and Commissioning of 3.5 Core 120 mm sq. Al armored XLPE Insulated,PVC cable Havells/RR-Kabel/KEI/Apar Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01.5 Feet below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. The job further includes cost of Road cut and refilling of same with cement concrete where required.(From Sub-Station to AVR Panel) |
| 42 | Supply/Laying/Testing and Commissioning of 3.5 Core 95 mm sq. Al armored XLPE Insulated,PVC cable Havells/RR-Kabel/KEI/Apar Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (01.5 Feet below ground level) including excavation and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping. The job further includes cost of Road cut and refilling of same with cement concrete where required.(From Sub-Station to AVR Panel) |
| 43 | Design/Fabrication/Supply/installation/testing and commissioning of CPRI Approved (IS/IEC:61439) Main LT Control Double Door (Outdoor type) panel (IP 65) Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming:200 Amp TPN MCCB 36kA with extended terminals Adjustable Thermal & Fixed Magnetic with ROH of Legrand/Siemens/ABB//LK make = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set(Accommodation for upto 06 Ckts), Multifunctional Meter = 1 no with CT coils 300 /5A = 1 set ,phase indicators =1set(2) Outgoing:(1) 160 Amps TPN MCB (16 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 04 No.The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing.(Football & Kho Kho ) |
| 44 | Design/Fabrication/Supply/installation/testing and commissioning of CPRI Approved (IS/IEC:61439) Main LT Control Double Door panel (IP: 65) Slopped Roof fabricated of 16 gauge sheet steel,the panel should have standing dust & vermin proof with gasket lockable door of 16 gauge sheet steel with angle iron stand of 2.5 feet height/ground clearance properly grouted in cement concrete of 1:2:4 ratio-filter . The Panel should be painted with Electro static powder coated colour, Siemens grey structural with proper chemical pre-treatment with film thickness 35-40 Microns,duly fitted with Voltmeter, R/Y/B Phase-indicators etc with baby insulators/glands/thimbles suitable for use at 415 Volts 3 Phase,4 wire 50Hz system complete in all respects complete in all respects with following:-(1) Normal Incoming:250 Amp TPN MCCB 36kA with extended terminals Adjustable Thermal & Fixed Magnetic with ROH of Legrand/Siemens/ABB//LK make = 1 no 400 Amp TPN Bus bar Al Strips = 1 Set(Accommodation for upto 06 Ckts), Multifunctional Meter = 1 no with CT coils 300 /5A = 1 set ,phase indicators =1set(2) Generator Incomer:200 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Multifunctional Meter = 1 no with CT coils 300 /5A = 1 set ,phase indicators =1set(2) Bypass Switch:3-Phase, Four Pole 100 Amp,415V Ac,50Hz with ROH Bypass Switch Havells/Seimens/LK/ABB Make for bypassing 60 KVA AVR.(3) Outgoing:(1) 100 Amps TPN MCCB (16-25 KA) of Legrand / Siemens/ ABB /Schinder /LK make = 06 No.( 04 for Football & 02 for Tennis/Basket Ball)The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing.(Main Panel) |
| 45 | Supply,Installation,Testing & Commissioning of 200 KVA , (11/ 0.433 KV ) Kv) 3-phase outdoor type oil immersed ONAN cooled Transformer complete with all fittings such as oil Conservator with drain plug,Silica gel,Breather,thermometer,tap changer,oil guage lifting lugs,Drain cum sampling value,filter valve with plug,first filling of fresh transformer oil ,weather proof HT Cable /LT cable Box earthing terminals etc complete .( Energy Efficient Level-2 ). of ALBA / Northsons /Northern / Zain Electricals / NGG make The transformer should be of standard make dully isi marked and manufacture unit should have CPRI Registration and BIS Certificate and type tested certificate upto required capacity levelThe complete testing of transformer will be carried out at manufacturing site by departmental representatives before assembling of same and contracting firm has to facilate in all aspects the deptt representatives upto manufacturing site for the said job. The job further includes comphrensive maintenance contract (with p/f of spares if needed) of Transformer for a period of two years reckoned from date of sucessful comissioning (As per Annexure \\"' A'') |
| 46 | Supply,Installation,Testing & Commissioning of BUCK BOOST TYPE (In Two Pices i.e Control chamber and dimmer chambers should in sperate units and coupled to each other & one unit /Chamber complete stabilizer shall not be accepted ) 200 KVA ,3-Phase,415V, L.T,Unbalanced Servo voltage stabilizer (OUT DOOR type) .that must take a load of 200 KVA at the Following Specifications No. of Phases = 3 No Input Voltage (L-L)= 208-460 Volts Output Voltage =415 volts ±1%(Phase to phase) & 230 volts±1%(Phase to neutral) Protection =Over voltage, under voltage & Overloading with TDR and Neutral failure . The Stabilizer shall be servo-controlled automatic ,ONAN cooled and provided with first filling of fresh filtered transformer oil having required dielectric strength .The Stabilizer shall be capable of smooth operation upto 10 % un-balanced in the load currents.The contractor /supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two year reckoned from commissioning.Inclusive of all applicapable taxes ( Automatic Electric(AE) / Andrew Yule /NGG Power Tec make /ALBA /Chinar /Casco The contractor has to faciltate in respects the departmental reprensatives for carrying out testing of stabilizer at manufacturing site before assembling and despatching to site of work.The Job further includes Comphrensive maintenance contract (CMC) for a period of two years reckoned from date of sucessful commissioning and handing over to intending department (The CMC includes quarterly servicing of Servo volatge stabilizer with replacement of damaged accessories /equipments both mechanical as well as electrical during operation what so reasons or as & when required) |
| 47 | Design, fabrication, supplying, assembling, erecting, connecting, testing and commissioning (outdoor double door) dust, damp and vermin proof free floor standing sheet steel enclosed non-drawout moduler type LT Main Panel (IP:65), fabricated out of suitable sized angle iron and flats, base channel and covered with 2.0mm thick CRCA sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking with existing panel as shown in drawing as per specification and mounted with the followings. Transformer and DG incomers alongwith buscoupler shall be colour coded compartment.The Panel shall have IP-65 rating. (The panel must be designed as per site requirement) The Switch gear should be adjustable type of Legrend /L&T /ABB /Simens(1) Incomer) 400 A, 415V, 50 KA having adjusting settings TPN MCCB thermal magnetic adjustable type . = 1 No's (1B) 630 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 120 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 800 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB |
| 48 | Providing and fixing of (Double door out door type ) front operated cubical panel (IP:65) 2 mm thick pressed sheet steel enclosure powder coated , dust free and vermin proof panel with hinged gasket and lockable arrangement doors of adequate size complete with interconnections. The panel is fitted with bus bars and provided with following accessories. Incomer 400 Amp TPN Panel type Change over Switch of Havells / Eq. make=1 No630 Amps TPN Aluminium Bus Bar with heat shrinkable sleeves and shall be colour coded = 1 SetDigital Multi function Volt Meter with C T of proper ratio. = 1 set each indicators = 1 Set each Outgoing400 Amps TPN MCCB with 50KA Breaking capacity of L&T /ABB /Legrend /Simens make = 1 No's200 Amps TPN MCCB with 36 KA Breaking capacity of L&T /ABB /Legrend /Simens make = 4 No's100 Amps TPN MCCB with 26 KA Breaking capacity of L&T /ABB /Legrend /Simens make = 2 No'sThe Job includes angle iron stand of required size whose legs are to grouted on cement concrete block including cost of civil materials and its carriage upto site The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 49 | Supply,Installation,,Testing & Commissioning of 400 Amps 4-Pole Bypass Changeover Switch of Havells/Eq.make ,with Angle iron stand to be whose legs are grouted on cement concreate block including cost of civil materials |
| 50 | Supply and Errection of 9 mtrs long Steel Tublur poles with base plate and caps duly welded,the pole is planted at 5- feet deep pit to be excavated and refilled with stones/boulders (SP33) |
| 51 | Providing and Laying of concrete jacketing for pole bottoms laid in 1:2:4 ratio of cement ,sand and 20 mm nominal size of aggregates with 4-feet underground and 0.6 feet above ground with 2-feet in dia.complete job including its form work and carriage of materials upto laying site. @ 0.5 Cum /Pole and for Construction of Bed for resting of CT/PT Unit |
| 52 | Supply and applying of one coat of Red oxide paint & two coats of Aluminium Paint Complete job. |
| 53 | Supply,Installation,Testing & Commissioning of H.T trivector meter enclosed in a cubical comparising of C.T (required ratio for 200KVA X-mer) ,P.T unit and H.T Energy modem meter capable of recording various electrical paramaters like KVA ,Amps,KVAR ,etc The Job includes providing and fixing of H.T ,ABC Cable 50 Sq.mm of required length for input supply to H.T and output supply to Transformer with required no.& Size of thimbles duly crimped with hydraulic crimping tool & making of necessary connections or cable termination Cable of required size as per instructions of engineer concerned.The Job includes Angle Iron Stand for resting of CT/PT Unit. |
| 54 | Supply & Fixing of Channel Iron Cross Arms /Angle iron Braces of Size duly painted with red oxide and 2 coats of Al. paint fitted with required size of nuts & Bolts for Construction of Transformer Bed on Tubular poles . |
| 55 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 56 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 57 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 58 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 59 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders reauired.etc as |
| 60 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 61 | Supply,Laying , stringing , jumpering , binding , testing & commissioning of 0.05 ACSR ,incl making of all necessary connections |
| 62 | Supply,Installation,Testing & Commissioning of Earthing to poles by way of S/f of GI Rod having 6 ft in length to be inserted in a pit including extending of earthing from from earth electrode to pole 25 x 3 mm GI Strip from battom upto pole |
| 63 | Supply,Installation,Testing & Commissioning of 11kv lighting Arrestor heavy type/station type with nuts & bolts |
| 64 | Supply,Installation ,Testing & Commissioning of 11kv fuse set with allied fittings complete job. complete with nuts & bolts. |
| 65 | Supply,Installation ,Testing & Commissioning of 11kv G.O set with allied fittings and handle complete job. complete with nuts & bolts. |
| 66 | Providing of G.I Plate earthing with 6-feet long G.I rod embedded underground with insertion of G.I pipe for watering and filling of char coal or Clay & salt in alternate layers also extension of eathing from rod to lighting arrestors , transformer body & Neutral of Transformer with Al. Strip fitted on poles with Epoxy insulators with cliffs of Sub Stations frame. The Job includes p/f of 1 ft x 1 ft PVC Main hole chamber. |
| 67 | Providing and fixing of Epoxy (Baby) insulators with its all accessories like fabricated steel cliffs of adequate sizes and nuts & bolts complete for resting/fixing of G.I earth upto lighting arrestor |
| 68 | Supply,Laying,Testing & Commissioning of 185 Sq.mm Single Core XLPE Al.Cable unarmoured 1100 volts of Havells /Polycab /Upar make and making of necessary connections.The Job further includes cost of P/F of required Size of thimbles duly crimped with hydraulic crimping tool & making of necessary connections. |
| 69 | Providing and fixing of Al.Solder Less Clamps for HT Transformer duly fitted with necessary nuts & bolts. |
| 70 | Supply & fixing of Anticlimbing Devices for HT /LT Poles. |
| 71 | Supply & Fixing of Danger plates for HT /LT Poles. |
| 72 | Supply,Laying,Testing & Commissioning of 3.5 Core , 120 Sq.mm XLPE /PVC insulated LT Power cables of havells /Polycab /Apar make.The cable is laid partially through walls with necessay cliffs saddles and partially laid underground incl digging and refilling ,Incl cost of p/f of Al thimbles on both sides dully crimped with hydraulic crimping tool and making of necessary connections to be laid from old DG Set to New DG Set and from transformer to DG Set |
| 73 | Supply and laying of DWC double layer Corrigated pipe having 75 mm dia to be laid under ground upto 50 Cm's in deep including execuation and refilling back and disposal of surplus earth complete job. |
| 74 | Supply ,Installation ,Testing and Commissioniong of Out Door type (Double door) Feeder Panels (IP:65) fabricated out of 2 mm thick pressed Sheet Steel enclosure Powder coated and vermin proof panel with hinged gasket and lockable arrangement doors of adequate size complete with interconnections. The panel is fitted with bus bars and provided with following accessories. (1) 400 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (2) Phase Indicator Sets = 1 SetThe Job further Includes providing and fixing of Angle Iron Stand for resting of Feeder Piller whose legs should be around 3 ft in height ,also legs should be grouted in cement concrete block upto 1.5 ft |
| 75 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 76 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 77 | Providing and laying of shock proof Rubber mats of 2mt. x 1 mt. and 12 mm thick in size |
| 78 | Earth work excavation of foundation trenches including dressing of sides and ramming of bottom, lift upto 1.5 mtrs, including getting out excavated soil and disposal of surplus soil lead upto 25 mtrs |
| 79 | Providing and laying of Stone soiling dry hand packed complete incl carriage of materials from source to site of work |
| 80 | Providing and laying of mud mat at a depth in 1:4:8 mix incl carriage of materials from source to site of work |
| 81 | Providing and laying of concreating in 1:2:4 incl carriage of materials from source to site of work |
| 82 | Reinforcement for RCC work incl carriage of materials from source to site of work |
| 83 | Centering and shuttering including shuttering propping etc and removal of form work after completion of job. |
| 84 | Providing and fixing of 4inch dia 10 ft Long GI Pipe (B-Class) |
| 85 | Supply & fixing of corrigated C.G.I sheets with 0.67 mm thick having Zinc coating not less than 2.257 gm/mts, 8mm dia meter bitumun, fixed with hooks & bolts including cost of G.I Lintel washers of sizes for construction of shed for housing of D.G. Set.including cost of ridges |
| 86 | Providing and installation of GI Chain Link fencing of required width in mesh size 50 mm x 50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per directions of engineer incharge 4 mm dia of GI Wire. The job includes providing and applying of one coat of redoxide paint and two coats of aluminium paint. |
| 87 | Supply/Installation/Testing and Commissioning of IK08 IP-66 protected high power 200 Watt.LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=130 Im/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @›=300 V AC and Auto resetting Safety Power Factor >0.95, THD(1) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10K external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.The job further includes replacement warranty of fixture from OEM (if damaged/burnt out what so ever reason) for a period of three years reckoned from date of successful commissioning /handing over of site to intending department. connection wires Philips/Wipro/LT /Regent /Endo Make. |
| 88 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Including Cost of Conduit)(Havells/Polycab/Anchor Make) & shall be approved before execution of work. |
| 89 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards. |
| 90 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 91 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysNov 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender