Tender For Purchase Of Equipment , Ph Multiparameter , Type: Benchtop Ph / Conductivity Multiparameter Meter. Application: Suitable For Laboratory Measurement Of Ph, Mv, Orp, Conductivity, Tds, Salinity, Resistivity, And Temperature. Measurement Parameter
Tender Overview
Project Description
Tender For Purchase Of Equipment , Ph Multiparameter , Type: Benchtop Ph / Conductivity Multiparameter Meter. Application: Suitable For Laboratory Measurement Of Ph, Mv, Orp, Conductivity, Tds, Salinity, Resistivity, And Temperature. Measurement Parameters: Ph, Mv, Relative Mv, Orp, Conductivity, Tds, Salinity, Resistivity, And Temperature. Meter Channels: Multi-Channel System With Minimum 2 Measuring Modules, Expandable / Customizable Up To 4 Channels.Display: Large Color Graphic Lcd Display With Clear Measurement And Calibration Indication. Ph Range: -2.000 To 20.000 Ph Or Better. Ph Resolution: Selectable Resolution Of 0.1 / 0.01 / 0.001 Ph Or Better. Ph Accuracy: ±0.002 Ph Or Better. Ph Calibration: Up To 6-Point Ph Calibration With Automatic Buffer Recognition. Buffer Recognition: Nist / Din / User-Defined Buffer Groups Or Equivalent. Mv / Orp Range: ±2000.0 Mv Or Better. Mv Resolution: 0.1 Mv Or Better. Mv Accuracy: ±0.2 Mv Or ±0.05% Of Reading, Whichever Is Greater, Or Better. Conductivity Range: 0.001 Μs/Cm To 3000 Ms/Cm Or Better. Conductivity Accuracy: ±0.5% Of Reading Or Better. Conductivity Resolution: Auto-Ranging Resolution With Minimum 0.001 Μs/Cm Or Better. Conductivity Calibration: Up To 6-Point Conductivity Calibration With Calibration Editing Facility. Cell Constant Range: Wide Selectable Cell Constant Range Suitable For Different Conductivity Probes. Tds Range: 0.001 Ppm To 200 Ppt Or Better. Salinity Range: 0.06 To 80.00 Psu / 0.05 To 42.00 Ppt Or Better. Resistivity Range: 2 Ohm To 100 Mega-Ohm Or Better. Temperature Range: -5°C To +105°C Or Better. Temperature Resolution: 0.1°C Or Better. Temperature Accuracy: ±0.1°C Or Better. Temperature Compensation: Automatic And Manual Temperature Compensation Facility. Read Modes: Auto-Read, Continuous, Timed Reading, And Single-Shot Reading Modes. Data Storage: Internal Memory For Minimum 2000 Data Sets With Date And Time Stamp. Calibration: Log Calibration Log Facility For Recent Calibrations With Active Calibration Viewing. Data Transfer: Usb And Rs232 Data Transfer Facility To Computer Or Printer. Alarm Facility: Set Point Alarm, High/Low Limit Alarm, And Calibration Due Alarm. User Methods: Facility To Store Multiple Password-Protected Measurement Methods Per Channel. Protection Rating: Ip54-Rated Housing Or Equivalent Splash And Dust Protection. Power Supply: Universal Power Adapter Suitable For 100-240 V Ac, 50/60 Hz Input. Accessories: Supplied Complete With Ph Electrode, Conductivity Probe With Temperature Sensor, Electrode Stand, Power Adapter, Ph Buffer Solutions, Conductivity Standard, Interface Cable, Operating Manual, And Meter Test Certificate. Certification: Ce / Tuv / Fcc Or Equivalent International Safety And Quality Certification. Warranty: Minimum 3-Year Warranty For Meter And Measuring Modules With Service Support.
BOQ
| Sl. No. | Item Description |
| 1 | PH Multiparameter |
| 2 | Type: Benchtop pH / conductivity multiparameter meter. Application: Suitable for laboratory measurement of pH, mV, ORP, conductivity, TDS, salinity, resistivity, and temperature. Measurement Parameters: pH, mV, relative mV, ORP, conductivity, TDS, salinity, resistivity, and temperature. Meter Channels: Multi-channel system with minimum 2 measuring modules, expandable / customizable up to 4 channels.Display: Large color graphic LCD display with clear measurement and calibration indication.pH Range: -2.000 to 20.000 pH or better. pH Resolution: Selectable resolution of 0.1 / 0.01 / 0.001 pH or better.pH Accuracy: ±0.002 pH or better. pH Calibration: Up to 6-point pH calibration with automatic buffer recognition.Buffer Recognition: NIST / DIN / user-defined buffer groups or equivalent. mV / ORP Range: ±2000.0 mV or better. mV Resolution: 0.1 mV or better. mV Accuracy: ±0.2 mV or ±0.05% of reading, whichever is greater, or better. Conductivity Range: 0.001 µS/cm to 3000 mS/cm or better. Conductivity Accuracy: ±0.5% of reading or better. Conductivity Resolution: Auto-ranging resolution with minimum 0.001 µS/cm or better. Conductivity Calibration: Up to 6-point conductivity calibration with calibration editing facility. Cell Constant Range: Wide selectable cell constant range suitable for different conductivity probes.TDS Range: 0.001 ppm to 200 ppt or better. Salinity Range: 0.06 to 80.00 psu / 0.05 to 42.00 ppt or better.Resistivity Range: 2 ohm to 100 mega-ohm or better. Temperature Range: -5°C to +105°C or better.Temperature Resolution: 0.1°C or better. Temperature Accuracy: ±0.1°C or better. Temperature Compensation: Automatic and manual temperature compensation facility. Read Modes: Auto-read, continuous, timed reading, and single-shot reading modes.Data Storage: Internal memory for minimum 2000 data sets with date and time stamp. Calibration: Log Calibration log facility for recent calibrations with active calibration viewing. Data Transfer: USB and RS232 data transfer facility to computer or printer.Alarm Facility: Set point alarm, high/low limit alarm, and calibration due alarm.User Methods: Facility to store multiple password-protected measurement methods per channel.Protection Rating: IP54-rated housing or equivalent splash and dust protection.Power Supply: Universal power adapter suitable for 100–240 V AC, 50/60 Hz input.Accessories: Supplied complete with pH electrode, conductivity probe with temperature sensor, electrode stand, power adapter, pH buffer solutions, conductivity standard, interface cable, operating manual, and meter test certificate. Certification: CE / TUV / FCC or equivalent international safety and quality certification.Warranty: Minimum 3-year warranty for meter and measuring modules with service support. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender