Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #58462880

Tender For Special Repairs To Bldg No P-Xxvi At Igoe Under Ge Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
87.39 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
13 days left
EMD
1.56 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repairs To Bldg No P-Xxvi At Igoe Under Ge Chennai

BOQ

Name of Work:- SPECIAL REPAIRS TO BLDG NO P-XXVI AT IGOE UNDER GE CHENNAI
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER,CHENNAI Name of Work: SPECIAL REPAIRS TO BLDG NO P-XXVI AT IGOE UNDER GE CHENNAI Contract No: CWE/CHE/ OF 2026-27 Name of the Bidder/ Bidding Firm / Company : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B/R PORTION:
3Demolition of cement concrete (unreinforced) of any description and in any position, sunken floor not otherwise specifically provided complete all as specified and directed
4M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding on roof slab of required thickness for levelling the surface of roof slab, finished fair and even complete all as specified and directed.
5M&L for complete removal of existing roof treatment of any description in patches viz. tarfelt or membrane surface or roof tiles etc. including grubbing up of tree roots and removing all the debris to a distance not exceeding 100m and preparation of concrete surfaces by scrubbing down with steel brushes and cleaning with water to remove all loose dirt / dust etc and applying the following roof treatment complete all as specified by Manufacture's instruction and as directed:-(a) Applying Ist course of treatment with 15 mm thick screed bed in cement mortar 1:4, mixed with water proofing compound @ 200ml per bag of cement over concrete surface .(b) Applying 2nd course of treatment with bituminious primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed.(c) Applying 3rd course of treatment with a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celsius applied at the rate of @ 1.2 kg/sqm.(d) Applying 4th course of treatment with APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application all as per Manufacture's instructions. (e) Applying 5th course of treatment with a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree celicious applied @ 1.2 kg/sqm over APP membrane,(f) Applying 6th course of treatment with one coat of solar reflective aluminium paint @ 0.10 Litre / sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately.
6Taking down the existing water proofing treatment from wall of any description including cement /lime mortar rendering and cleaning the surface with water and applying 10 mm thick rendering in cement mortar 1:3 mixed with liquid water proofing compound @ 200 ml per 50kg of cement, cleaning and preparation of newly plastered wall surfaces and applying the following water proofing treatment all as specified by Manufacture's instruction and as directed (a) Applying 1st course of treatment with bituminous (oil based) primer confirming to IS-3384 @ 0.4 litre /sqm over the screed bed.(b) Applying 2nd course of treatment with a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree Celsius and applied @ 1.2 kg/sqm.(c) Applying 3rd course of treatment with APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid with 75 mm side overlap and 100 mm overlap by forced / torch application as per Manufacture's instructions. (d) Applying 4th course of treatment with a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree Celsius and applied @ 1.2 kg/sqm over APP membrane. (e) Applying 5th course of treatment with one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed. Note:- WPC shall be measured and paid separately.
7Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed by Engineer-in-charge
8Dismantling of PGI / CGI / Galvalume sheets of any description as in roof coverings complete all as specified and directed.
9S&F 0.50mm thick corrugated (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed.
10S&F mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. not exceeding 10 kg each brackets, conforming to Fe.290 Gde-E-165 (Brackets over 10Kg each to be measured under 'Structural Steel') complete all as specified and as directed
11S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B all as specified and as directed
12M&L for cutting holes into or through brick / stone walls build in cement mortar or cement lime mortor ,of superficial area not exceeding 150 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type Bl as required complete all as specified.
13M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortor 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good cutting not exceeding 10cm in girth complete all as specified and directed.
14Supply and laying of CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceilings or laying in floors complete with all pipe fittings including taking up or down the existing pipe line of any description complete all as specified for following sizes :-
1520mm outer dia bore
1625mm outer dia bore
1732mm outer dia bore
18S&F in repairs vitreous china wash down water closet pan, dual flush system cascade type selected colour with built in cistern floor /wall mounted type with P or S trap and matching seat cover including all fittings all as specified and directed by Engineer-in-Charge.
19S&F in repairs vitreous china wash basin of oval counter foul type including fitting inside granite platform, including waste coupling, waste pipe and brackets etc complete all as specified and directed.Note: The RCC slab and granite platform shall be measured and paid separately under relevant item.
20S&F in repairs 15mm dia Bib taps cast fancy type, chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule for fancy type Chromimum plated complete all as specified and directed. Make:Jaquar
21S&F in repairs two way bib tap 15 mm bore chromium plate with crtuch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union complete all as specified and directed. Make:Jaquar
22S&F in repair 15mm dia CP bib cock nozzle with flange (washing machine tap) complete all as specified and as directed. Make:Jaquar
23S&F in repairs 15 mm dia pillar tap mixer for both Hot and Cold long neck with aerator fancy type cast copper alloy with crutch handle screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe or for brass ferrule etc complete all as specified and as directed. Make:Jaquar
24S&F in repair wall mixer 3-in-1 system with provision for over head shower including hand shower complete all as specifed and directed. Make:Jaquar
25S&F in repairs health faucet, hand shower with 1 metre flexible tube with wall hook chromium plated complete all as specified and directed. Make:Jaquar
26S&F in repair angular stop cock 15 mm dia brass chromim plated fancy type with long shank, screwed down high pressure with crutch or butterfly handle screwed down both ends for iron pipe or for union complete all as specified and directed. Make:Jaquar
27S&F in repair over head shower rose & shower arm with revolving joint of size 100mm dia round shaped single flow, ABS body chromium plated complete all as specified. Make:Jaquar
28S&F in repair toilet paper holder with flap recessed type matt chromium plate complete all as specified. Make:Jaquar
29S&F in repair soap dish, matt finished chromium plated (MCH /Colour CP) complete all as specified Make:Jaquar
30S&F in repair corner glass shelf 300mm, matt finished, chromium plated (MCH/Colour CP) with bracket complete all as specified and directed.Make:Jaquar
31S&F in repair towel ring round with round flange chromium plated complete all as specified Make:Jaquar
32S&F in repairs towel rail 600mm long with flanges, chromium plated complete all as specified Make:Jaquar
33S&F in repair cabinet mirror of size 330 mm X 430 mm with shelfs as fixed complete all as specified and directed.Make:Jaquar
34S&F in repairs looking mirror of size 600mm x 450mm, bevelled edge on selected quality mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers and framed with aluminium channel all round etc., complete all as specified
35S&F in repair tumbler holder chromium plated complete all as specified Make:Jaquar
36S&F in repairs Sink made out of stainless steel 1mm thick with drainage board for kitchen and laboratory with plugs washers and wastes, including beading in cement mortar to dwarf wall including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm ,bowl size of 410mmx330mmx160mm including 40mm size CP waste coupling and PVC waste pipe complete all as specifiedMake : Nirali/Jayna/Diamond/ Parryware
37S&F in repair 15 mm bore sink cock with swinging spout wall mounted model with wall flange complete all as specified and directed. Make:Jaquar
38S&F in repairs 15mm PVC connection 450mm long of superior quality as specified.
39S&F in repairs PVC waste pipe for wash hand basin of size 31/32mm dia , 800mm length complete all as specified and directed Make : Prayag
40S&F in repairs PVC waste pipe for Sink waste pipe of size 38/40mm dia,1150mm length complete all as specified and directed Make : Prayag
41S&F in repair CP cockroach trap (127mmx127mm) with waste hole/with out waste hole all as specified and directed. Make : Prayag
42S&F in repair Stainless steel plate rack of size 24\\"X36\\"X10\\" fixed on wall with stainless screw with wooden plugs near the kitchen sink including all accessories and making good the disturbed wall tiles/concrete surface complete all as specified and directed.
43S&F in repair Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25 mm dia bore pipes complete all as specified and directed.
44S&F in repairs rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position of 1000 litres capacity including 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
45S&F in repairs PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified
46S&F in repairs PVC (SWR) pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified
47S&F in repairs PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified
48S&F in repairs PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to wall complete all as specified
49S&F in repairs PVC (SWR) bend with access door of any radius of 75mm dia complete all as specified
50S&F in repairs PVC (SWR) bend with access door of any radius of 110mm dia complete all as specified
51S&F in repairs PVC (SWR ) vent cowl of 110mm bore complete all as specified
52S&F in repairs PVC (SWR ) vent cowl of 75mm bore complete all as specified
53S&F in repairs PVC (SWR) branch piece, double Y equal or unequal 110mm bore with access door complete all as specified
54S&F in repairs PVC (SWR) branch piece, double Y equal or unequal 75mm bore with access door complete all as specified
55S&F in repairs PVC (SWR) junction double, double T equal or unequal 110 mm bore with access door complete all as specified
56S&F in repairs PVC (SWR) junction double, double T equal or unequal 75 mm bore with access door complete all as specified
57Dismantling floor, hearth or wall tiling including cement mortar bedding / existing backing coat and removing serviceable tile to store and rubbish off the premises complete all as specified .
58M&L for Vitrified ceramic light colored double charged tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm of approved pattern as in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tile over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
59M&L for Vitrified ceramic light colored double charged tiles of 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm of approved pattern on vertical surfaces of wall such as dado,skirting etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tile over and including backing coat in cement mortar 10mm thick 1:3 on fair faces of brick or concrete surfaces complete all as specified and as directed.
60M&L for non skid ceramic coloured joint free tile 7mm to 8 mm thick concept tile, design as approved (sqaure or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc of approved pattern over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tile complete all as specified and as directed.
61M&L for glazed coloured ceramic concept designer tiles of 7mm thick and area exceeding 0.11 sqm and not exceeding 0.18 Sqm as approved by GE, fixed in vertical surfaces such as in dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over and including a backing coat in Cement Mortar 1:4, 10mm thick all as specified and directed.
62Demolition of stone slabs and tiles of any description or thickness, laid bedded and pointed in cement morter as in floors, platforms, aprons etc. complete all as specified.
63M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement mixed with admixture of pigment to match the shade of granite stone including grinding and polishing of approved quality of any size set and jointed in grey cement slurry laid over and including 15 mm thick screed bed in CM (1:4) including polishing the granite stone by using mechanical grinder and moulding edges complete all as specified and as directed.
64M&L for rounding to edges of stone slabsone edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
65M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified.
66M&L for Machine cut kota stone slab flooring 20mm to 25mm thick over and including 15mm thick cement screed in cement mortar 1:4 including pointing, moulding the edges in white cement (1:2) using marble dust with admixture of pigment to match with shade of kota stone complete all as specified and directed
67M&L for Kota stone slab 20mm to 25mm thick as in riser of steps, skirting, dado and pillar laid over and including backing coat 10mm thick in cement mortar 1:3 including pointing, moulding the edges in white cement 1:2 using marble dust with admixture of pigment to match with shade of kota stone complete all as specified and directed.
68Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specifed and directed.
69M&L for 75 mm thick, plain cement concrete 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishing the surface even and smooth without using extra cement, complete all as specified and directed.Note : concrete shall be laid at a stretch not exceeding 3.0 m in length and every turning / corners.
70Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed
71M&L for providing Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
72M&L for reinforced cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves, filling in steel frames and the like complete all as specified and directed.Note:Reinforcement shall be measured and paid separately under relevant item.
73M&L for Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified
74Taking down cement plaster of any description on brick or stone walls or from concrete surface including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material outside Cantt area, complete all as specified and directed.
75Demolition of brick or stone masonry, built in cement mortar of any description including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
76M&L for brick work with fly ash old size bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and directed
77M&L for brick work with fly ash bricks straight or curved on plan to any radius, as in half brick thick wall built in cement mortar 1:4 complete all as specified and directed
78S&F Gl wire netting 0.90mm dia & 12mm mesh in patches of lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified
79M&L for dubbing out average 15mm thick on irregular face of walls in patches in cement mortar 1:4 complete all as specified and directed.
80M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces of walls in two layers ,first layer 10 mm thick in CM 1:6 and subsequent layer 5 mm thick in CM 1:4 mixed with water proofing compound as per Manufacturer's instruction, finished the surfaces even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately under relevant item
81M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
82M&L for rendering 5 mm thick in cement mortar 1:3 as in ceiling surfaces in patches finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
83Supply only Liquid water proofing compound Make: Sika / Fosroc / Choksey
84M&L for preparation of new plastered surfaces of wall and applying plaster of paris putty of 1 mm thickness over a coat of primer over newly plastered surface, finished even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as per Manufacturer's specification and as directed.
85M&L for complete removal of existing treatment of old surfaces of wall and applying plaster of paris putty of 1 mm thickness over coat of primer over the prepared surface, finished even and smooth and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as per Manufacturer's specification and as directed.
86M&L for preparation of new plastered surfaces of ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete all as per Manufacturer's specification and directed.
87M&L for complete removal of existing treatment of any description from surfaces of ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete all as per Manufacturer's specification and directed.
88M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls complete all as specified and as directed. Make : APEX of Asian or other equivalent make of shalimar / Nerolac/ Berger.
89M&L for complete removal of existing treatment of any description and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces complete all as specified and as directed Make : APEX of Asian or other equivalent make of shalimar / Nerolac/ Berger.
90Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area not exceeding 1.5 sqm each including separating guard bars/grills/wire mesh etc. complete all as specified and as directed by the Engineer-in-Charge
91Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exceeding 1.5 sqm but not exceeding 4sqm each including separating guard bars/grills/wire mesh etc complete all as specified and as directed by the Engineer-in-Charge
92Taking down chowkats (or) frames of any description with shutters (without taking off shutters from the frame) of area exceeding 4.0 Sqm but not exceeding 7.5 Sqm each including separating guard bars/grills/wire mesh etc complete all as specified and as directed by the Engineer-in-Charge
93Taking down shutters of any description exceeding 1sqm but not exceeding 2sqm each including builders hardware complete all as specified and as directed by the Engineer-in-Charge.
94S&F second class hard wood, plain solid straight chowkats and frames rebated on the solid, rounded or chamfered put together with glue pinned at joints, supplied and fitted complete all as specified and as directed.
95S&F 35mm thick second class hard wood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze, etc. with sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
96S&F plain framed, panelled shutter 35mm thick (two panel) with lock rail & panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces ,second class hard wood rail & style of size all as per IS: 1003 (Part I), kiln seasoned & chemically pressure treated complete all as specified and as directed.
97S&F in repairs Solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with 19mm MS square tube of 19 gauge metred cut at two corners and joined by inserting two Nos of 150mm long brackets of 15mm x 15mm MS square tube inside the 19mm x 19mm square tube fixed to wall by drilling 100mm long MS screws using PVC fastener all as per specification and directed.
98S&F Factory made solid PVC moulded door shutter with wood free EPS 28 to 30mm thick with 2,4,6 raised panel design with 2mm thick moulded Prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying and fixing in frame at site as per specification and drawing and all as directed.
99S&F Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 medium weight cold rolled mild steel etc., complete all as specified and as directed.
100S&F Butt hinges, 100mm size medium weight cold rolled mild steel complete all as specified and as directed.
101S&F Aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
102S&F Aluminium anodised barrel tower bolts, extruded section of size 200mm long complete all as specified and as directed.
103S&F Aluminium handles cast type anodised 125 mm size complete all as specified and as directed.
104S&F Aluminium handles cast type anodised 150 mm size complete all as specified and as directed.
105S&F Aluminium alloy, anodised sliding door bolts 300mm long with hasp and stable (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections as specified and as directed.
106S&F mild steel 300 mm, ordinary rat rail rod pattern springs including rollar and rollar plate complete all as specified and as directed.
107S&F 140 mm over all length of cover plate, floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and as directed.
108S&F Aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.4mm fixed with aluminium wire staples fixed to wood/steel frames complete all as specified and as directed by the Engineer-in-Charge
109M&L for preparation of new wooden surfaces of any description exceeding 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified
110M&L for preparation of new steel surfaces of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified.
111S&F aluminium powder coated (Minimum thickness of powder coating 50 micron) frame for doors / windows / ventilator / partition including glassing clips with one or more tracks and joining cleats for fixing and other accessoreies as required complete all as specified and directed by Engineer-in-Chage .
112S&F aluminium powder coated sliding window (for width 1.00 M above and openable for below 1.50 M width) using alumimium section weighing not less than 0.495 Kg per RM for frame and 0.48 Kg per RM for sliding shutters including aluminium anodised snap beads, screws and fixed alongwith same section in three rolling sliding shutters two for fully glazed with 5mm thick tinted glass fixed with glazing clips, and one for wiremesh shutters etc including fixings of all builders hardware such as wire mesh ,hinges, bow handles, locking arrangements etc complete all as specified and directed by Engineer-in-Charge.
113S&F aluminium powder coated ventilators using alumimium section weighing not less than 0.48 Kg per RM for frame louvers aluminium anodised snap beads, screws and fixed alongwith with 5mm thick frostes/pin headed glass fixed with glazing clips, and one for wire mesh shutter fixed on frame including fixings of all builders hard ware such as wirmesh, hinges, bow handles, locking arrangements etc., complete all as specified and directed by Engineer-in-Charge.
114S&F mild steel framed work such as grills, gratings etc., with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
115S&F Sheet glass 5.5mm thick, plain ordinary quality & glazing with oil putty in square exceeding 0.5 sq.m in each pane fixing to aluminium frame work including hacking out old broken glass (any thickness, size, quality or description ) from Aluminium section fixed with beads/glazing clips complete all as specified and directed.
116S&F factory made kitchen cabinet shutter/partition 20mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600Kg/Cum and laminated on both side by laminate sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, including supply and fixing factory made solid foam uPVC profile for kitchencabinet frame 45mm x 20 mm of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets(Single extruded) having density 600Kg/Cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardent having necessary screw holding capacity. Frame shall be fixed to wall using expandable fastner with necessary stainless steel screws, and necessary fittings (heavy duty, stainless steel, ISI marked, make approved by GE) for kitchen cabinet as under all complete as per direction of Engineer-in-charge and approved by GE. (a) Stainless steel drawer system (ISI Marked) - 12 Nos(b) Stainless steel Crockery basket (ISI Marked) - 6 Nos(c) Stainless steel drawer organizer for cutlery (ISI Marked) - 6 Nos(d) Stainless steel pull out tray (ISI Marked) fixed with approved panel- 6 Nos(e) Stainless steel corner unit (ISI Marked) - 6 Nos, etc., Note: The colour/design of kitchen cabinet and accessories of cabinet shall be approved by GE and Contractor shall take necessary approval of GE before commencement of the kicthen cabinet work. The rate of kitchen cabinet shall be inclusive of all accessories fixed with the kitchen cabinet, no extra charges shall be paid separately against accessories fixed in the kitchen cabinet.
117S&F in repairs 12mm thick plywood, grade BWR, fixed with screws to timber frame work type BB with decorative laminate type1 0.90mm thick of surface finish colour and pattern as approved and other side white lamination type 1 0.5mm thick fixed with approved adhesive as per manufacturers instructions complete all as specified
118S&F in repairs 18 mm thick prelaminated particle board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work complete all as specified and directed.
119S&F 6mm thick external teak wood lipping over 18/19mm thick particle board/plywood fixed with nails complete all as specified and directed.
120S&F continous (piano)hinges mild steel, bright finish or electro galvanised width of flaps (when open) 30mm complete all as specified .
121S&F in repairs Locks, drawer, cupboard shutters grade I, size 75 mm , Brass 4 levers complete all as specified
122S&F in repairs stainless steel cabinet hinges /self closing hinges (Bombay Hinges) complete all as specified
123S&F in repairs Magnet closures to cabinet cupboards complete all as specified
124S&F in repairs stainless steel curtain rods with L clamps and with suitable globe brackets and brass screws complete all as specified
125M&L for small articles such as hold fasts etc. of Flat Iron 25 x 3, Grade confirming to Fe-290 Gde E-165 complete all as specified
126M&L for preparing small articles such as hold fasts, end of posts etc. of area not exceeding 0.1Sqm and treated with Cresote Oil/ black bituminous paint complete all as specified
127M&L preparing of wood and wood based materials, steel, and iron work, new or old and treating ends of posts, backs of chowkats, etc, area tarred exceeding 0.1 sq m but not exceeding 0.5 sq m each and treated with tar or coat tar black paint complete all as specified
128M&L for plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate for fixing of hold fast complete all as specified and directed.
129M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate, as in floor, 25mm average thickness, mixed with PIDI PROOF LW or equivalent of other makes listed herein after at the rate of 200ml per bag of cement complete all as specified and directed.Note: Liquid Water proofing compound shall be measured and paid separately under relevant item.
130M&L for Plain Cement concrete 1:5:10 type E2 using 40mm graded stone aggregate in mass concrete in sunken floor, bed blocks, coping lintel upto 1.5m span and similar work complete all as specified and directed.
131M&L for cleaning the surface (for sunken floor portion) with wire brush and washing with hydrocholoric acid to remove dust, dirt, oil grease, loose particle etc and applying a coat of water base acrylic polymer modified MIX GUARD AC or other equivalent make appoved by GE @ 1kg per sqm as in part A (Powder) and Part B (liquid) in a ratio of 3:1 with and including 20mm thick rendering in CM 1:4 as in sunken floor slab, walls mixed with intergal water proofing compound and finished even and smooth complete all as per Manufacture's instruction and all as directed by Engineer-in-Charge.
132INTERNAL ELECTRIC SUPPLY
133Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or takingcredit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified
134M&L for point wiring using approved colour coding as per IS, with stranded copper conductor of size 1.5 sqmm (nominal area), single core, with PVC insulated and unsheathed stranded copper conductor cabel of 1100V grade (FRLSH), ISI-694 marked concealed drawn through in and including non metallicheavy duty, rigid PVC conduit of minimum 20mm bore in wall/floor and fixed on ceiling/roof etc, after cutting, chasing the wall etc and making good of disturbed surface,including all accessoriesetc., heavy duty ISI marked, including pressed steel modular sunken boxes of suitable size with minimum thickness 2mm duly concealed in wlls for housing of modular switchs, switch sockets outlets, fan regulators etc., including provision of 1.5 sqmm (nominal area) (FRLSH) single core, PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for complete for :-Note: Cutting chaese shall be measured and paid seperately under respective item
135One light point controlled by one switch
136One fan point controlled by one switch
137One 3 pin socket outlet 5 amps on the same board controlled by one switch.
138One 3 pin socket outlet 5 amps on independent board controlled by one switch.
139One bell/buzzer point controlled by one bell push
140One light point controlled by two 2-way switch
141All as per item No. 128 above but for One 3 pin socket outlet 15 Amps, independent, with 4.0 sqmm cable complete all as specified ( for Geyser & Ac)
142All as per item No 128 but for one socket outlet three pin 15 Amps controlled by one switch, independent board with 2.5 sqmm size cable complete all as specified
143S&F modular cover plate with frame 1 module complete all as specified
144S&F modular cover plate with frame 3 module complete all as specified
145S&F modular cover plate with frame 4 module complete all as specified
146S&F modular cover plate with frame 8 module complete all as specified
147S&F in repairs modular switches suitable for type AC 240V, 6 Amps 1 module complete all as specified
148S&F in repairs modular switches suitable for type AC 240V, 6 Amps 1 module 2 way complete all as specified
149S&F in repairs modular sockets suitable for type AC 240V, 6 Amps 2 module complete all as specified .
150S&F in repairs modular switches suitable for type AC 240V, 16 Amps 1 module complete all as specified
151S&F in repairs modular power sockets suitable for type AC 240V, 16 Amps 2 module complete all as specified .
152S&F in repairs modular bell switch suitable for type AC 240V, 6 Amps complete all as specified .
153S&F in repairs call bell of multi music type A/C 230 volts complete all as specified and directed by Engineer-in-Charge.
154S&F in repairs ceiling rose, polycarbonate, isolated body with 2 to 3 terminals complete all as specified
155Taking down ceiling fan and removing blades from fan body and depositing to store yard of AGE E/M including connecting rod, cotter pins and all accessories complete all as specified
156S&F ceiling fans complete with blades, down rods, electronic regulator (2 Modular) and accessories, 230 V, 1200 mm sweep five star rated with brushless direct current (BLDC) motor, complete all as specified and directed.
157S&F exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers ,complete all as specified and directed.
158S&F in repairs 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or other equivalent make of Philips/Bajaj.
159S&F in repairs 10 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminum housing with wide range of wattages to suite variety of application areas, complete all as specified and directed Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or other equivalent make of Philips/Bajaj.
160S&F in repairs 15 Watts round ceiling COOL LIGHT is a functional range of aesthetically designed surface mounted downlights with aluminum housing and heat sink for better thermal performances, complete all as specified and directed Make : Havells Cat No. INTEGRANXTRDDLRSURD15WLED865S or other equivalent make of Philips/Bajaj.
161S&F in repairs10 Watts Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs, complete all as specified and directed Make : Havells Cat No. HEXAFT10WLED857SSYMBOPC or other equivalent make of Philips/Bajaj.
162Taking down the existing geyser, refixing the same after all necessary plumbing and electric works done and make necessary repairs if any, complete all as specified and as directed
163Taking down AC box any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
164S&F MCB Power unit with 4 module steel box consisting of 3 pin 24 Amps socket with Plug top and MCB SP 25 Amps, suitable for operation of AC & Geysers etc., complete all as specified. Make :- Havells/Legrand/Anchor
165Taking down sub main wiring any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specified and directed
166S&F sub main wiring complete with two runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable (FRLSH) of 1100 volts grade drawn through exisitng non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed Note:- Two runs of PVC insulated cable 10 sqmm and one run 10 sqmm of earth wire and one run of conduit including accessories shall be measured as one unit length.
167Taking down MCB DB any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
168S&F MCB distribution board made of 1.2mm thick special grade CRCA sheet, powder coated with high quality weather proofing paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 430 Volt 12 way MCB DB , SPN with 200 Amp rated bus bar shall conform to IP 38 protection including taking down the old one complete all as specified and directed by Engineer-in-charge
169S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection complete all as specified.
170Taking down MCBs any type and any size complete after taking proper disconnecting electric supply properly and making good surface complete all as specified and directed.
171S&F MCB of rating 240 Volts, SPN 63 Amps complete all as specified and directed.
172S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts complete all as specified and directed.
173M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below ground level connected to GI 4 mm earth wire by means of bolts, nuts check, nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board including 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion including taking down complete all as specified and as directed.
174S&F LED security light fitting 35 Watts made out of pressure die cast aluminium powder coated housing high impact resistant 4 mm thick toughened glass cover and matrix of power LEDs in built electronic driver up to 4 KV surge protection fitted with adjustable pole adopter to enable on site tilt angle setting and input power 25 W system lumens 85/W operating voltage 160-260 V including brackets made out of 25 mm / 20 mm dia GI medium grade tubing of suitable length and bend to shape including fixing MS flat iron clamps, bolts & nuts as per site requirement complete all as specified and as directed.
175M&L for cutting chases in stone concrete block and slab wall, pining in making good to facings where required and pointing in cement mortor 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm girth complete all as specified and directed.
176EXTERNAL WATER SUPPLY:
177Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/loose soil for laying cables / pipes / erection of poles etc., not exceeding 10Sqm on plan all as specified and as directed.
178Returning filling in soil including spreading, leveling, watering, well ramming in layers not exceeding 25 cm each all as specified and as directed.
179Removingof surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
180S&F in repairs galvanised steel water tubing 40mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., laid in trenches complete all as specified
181S&F in repairs galvanised steel water tubing 25mm bore medium grade with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc., fixed complete to walls and ceilings or laid in floors complete all as specified .
182S&F in repairs 25mm bore Gun metal globe / Gate valve conforming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings/ fixutres like nipple, union etc, complete all as specified and directed.
183S&F in repairs of Gun metal globe / Gate valve conforming to IS 778-1984 with iron wheel head, screwed both ends for 40mm bore iron pipe including all fittings/ fixutres like nipple, union etc, complete all as specified and directed.Make: BIR/ Leader/ Zoloto
184M&L for construction valve pit of size 50cm X 50cm X50cm in brick mansory for sluice valves of 40mm/ 50mm dia complete covered with 3.15mm thick MS sheet cover including angle iron frame and locking arrangement including earth work ,, plastering and painting etc. complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58462880
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 87.39 Lakhs
LAST DATE 30-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Bldg No P-Xxvi At Igoe Under Ge Chennai
Basic Detail
Tender No 88516/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 10 Nov 2026
Submission Date 30 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value 87.39 Lakhs
Tender Fee 1000
EMD 1.56 Lakhs
Exemption Available
Document List
2592e51a-a05d-4f39-97c2-3c5111d9f1c6.html
BOQ_895312.xls
TENDER88516.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

2592e51a-a05d-4f39-97c2-3c5111d9f1c6.html

xls

BOQ_895312.xls

pdf

TENDER88516.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender