Tender For Addition/Alteration To 41 Sqn Bldg Af Stn Palam Under Ge (Af) Palam Delhi Cantt-10
Tender Value
43.42 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
86900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration To 41 Sqn Bldg Af Stn Palam Under Ge (Af) Palam Delhi Cantt-10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Nov-2026 | CORRIGENDUM NO 1 | BOQ | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n exc 15 cm deep in soft/ loose soil including removing bushes/ small trees etc complete all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.5 m deep for foundations, cesspits,manholes, etc or removing the earth from existing drain and getting out in soft / loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including levelling, watering and well ramming in layers n exc 25 cm thick in soft / loose soil complete all as specified and as directed. |
| 4 | Removing excavated material to a distance n exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 5 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation complete all as specified and as directed. |
| 6 | M&L for reinforced cement concrete (Nominal Mix) (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundation, rafts, footings, foundation, beams, plinth beams, bases for columns etc basement slab complete all as specified and as directed. |
| 7 | M&L for reinforced cement concrete (Nominal Mix) (1:2:4) type B1 (using 20mm graded stone aggregate) as in columns, pillars, piers, post struts complete all as specified and as directed. |
| 8 | M&L for reinforced cement concrete (Nominal Mix) (1:2:4) type B1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies complete all as specified and as directed. |
| 9 | Dismantling of brick work or stone/boulders masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars etc. and rubbish materials removed from site complete all as specified and as directed. |
| 10 | M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radious built in CM (1:4) complete all as specified and as directed. |
| 11 | Demolition of cement concrete of any description and in any position and removing surplus spoil out of defence land where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 12 | M&L for 75mm PCC (1:3:6) type C2 (using 20mm graded stone aggregates) as in plinth protection and path finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 13 | M&L for 40mm thick damp proof course to horizontal or vertical surfaces including necessary use and waste of formwork in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregates) complete all as specified and as directed. |
| 14 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete flat complete all as specified and as directed. |
| 15 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions (rough finished surfaces of concrete) in square, ractangular or polygonal complete all as specified and as directed. |
| 16 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings girders, bressumers, lintel, cantilevers, shelves including supports overhangs etc also splays between floors and beams in rough finished surfaces of concrete complete all as specified and as directed. |
| 17 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), for rough finished surface of concrete complete all as specified and as directed. |
| 18 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 19 | Description all as per srl item No. 18 above but 8mm dia as in stirupps, spacers and binders complete all as specified and as directed. |
| 20 | M&L for 15mm thick cement plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 21 | M&L for 15mm thick cement plaster in cement mortar (1:4) on other than fair faces of brick or concrete surface with mixed with water proofing compound, finished even and fair complete all as specified and as directed. |
| 22 | M&L for 5mm thick cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed. |
| 23 | M&L for three coats of white wash on newly plastered surfaces of wall including preparation of wall surfaces complete all as specified and as directed. |
| 24 | M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of wall surfaces complete all as specified and as directed. |
| 25 | M&L for preparing new plastered or unplastered wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 26 | M&L for virified ceramic tiles (light shade) 10mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and includingh 15mm thick cement screed bedding layer in cement mortar (1:6) complete all as specified and as directed. |
| 27 | Description all as per ser item No. 26 above but as on vertical surfaces such as skirting etc over and including 10mm thick cement plaster with cement mortar (1:4), finished even and rough to receive tiles complete all as specified and as directed. |
| 28 | M&L for non skid joint free ceramic coloured tiles of area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and 6-7 mm thick as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including over 15mm thick screed bed or bedding layer with cement mortar (1:6) complete all as specified and as directed. |
| 29 | M&L for coloured ceramic glazed tiles of size (300 x 450)mm x 6-7mm thick fixed with neat cement slurry as on vertical surface to wall pointing in white/coloured cement to match over and including 10mm thick rendering in cement mortar (1:4) with and including dismantling old tile complete all as specified and as directed . |
| 30 | M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15mm thick bedding layer of CM (1:6), in any position including dismantling old granite complete all as specified and as directed. |
| 31 | M&L for 18 to 20mm thick machine cut Kota stone as in flooring laid over and including 15mm thick screed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the colour of stone slab including rubbing and polishing, in any position including dismantling old stone complete all as specified and as directed. |
| 32 | S&F stainless steel pipe railing of any size pipes in horizontal and vertical directions, all welded together, bend to shape and fixing both ends in floor complete all as specified and as directed. |
| 33 | M&L for providing false ceiling of 12mm thick fine fissure board sharped finished mineral fiber acoustic false ceiling tiles with back of the duly sanded and finshed with a coat of protective paint and front duly finished false system of size (600 x 600)mm having noise reduction co-efficient of 0.55 light reflection of 80% thermal conductivity k=0.057 W/WWC and humidity resistance of 95% fixed to true look PVC die KL -24 suspension system (Hot dipped a galvanised steel section) of exposed T Section consisting of perimeter wall angle of size (24 x 24)mm of thickness 0.45mm c/c universal main runner of T Shape with double rotary siticing of size (38 x 25)mm of lengh 1200mm made from 0.33GS steel of lengh 3.60 mtr to be spaced at (600 x 600)mm size c/c CRO runner T shape wtih double rotary siticing of size (30 x 24)mm of length 1200mm made 0.25 thick GS sheet spaced @ 600mm c/c (600mm x 600mm) size complete all as specified and as directed. |
| 34 | M&L for solid PVC wall lining consisting of 5mm thick supreme prelaminated colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed. |
| 35 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and as directed. |
| 36 | Taking down chowkats or frame with shutters (without taking off shutters from the fames) area not exc. 1.5 sq m each complete all as specified and as directed. |
| 37 | Taking down chowkats or frame with shutters (without taking off shutters from the fames) area exc. 1.5 sqm but n exc 4.0 sqm each complete all as specified and as directed. |
| 38 | M&L for anodized aluminium powder coated (minimum thickness of powder coating 50 micron) door shutter having (150mm x 44mm x 2.85mm thick) bottom rail, 150mm x 44mm x 3mm thick middle rail, 100mm x 44mm x 2.85mm thick stile and top rail including necessary fitting joinery cleat, glazing, packing, snap beading (10mm x 10mm), powder coated aluminium handle 200mm long (02 Nos), 3 Nos 100 mm size chromium plated butt hinges, 2 Nos 200mm size aluminium tower bolt and double action floor door spring hydraulically regulated including frame of section (100 mm x 44 mm x 2.85mm) and bottom portion covered with 9mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination (colour/design approved by Engr-in-Charge) fixed to aluminium frame and top portion covered with 5.50 mm thick glass and pattern, one mortice latch with two levers brass body (Make:- Harrison) and fixing complete all as specified and as directed. |
| 39 | M&L for anodized aluminium powder coated (minimum thickness of powder coating 50 micron) windows/ventilator shutter sliding type having (75mm x 44mm x 2.85mm thick) stiles bottom rail and top rail including necessary fitting joinery, cleat, glazing, packing, snap beading 10mm x 10mm, 2 nos of anodized aluminium handle 150mm size etc including frame three track of section (100mm x 44mm x 2.85mm) with and including 5.00 mm thick tinted glass and including aluminium deco grill (50mm x 50mm) mesh size complete all as specified and as directed. |
| 40 | Providing, supplying, installing, testing and commissioning of double-leaf sliding glass door assembly at the entrance, comprising 12mm thick clear toughened safety glass panels, complete necessary brackets, clamps, patch fittings, locking arrangement and all other required accessories, complete in all respects as per the directions of the Engineer-in-Charge. |
| 41 | M&L for mild steel pipe 25mm dia curtain rod with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade complete all as specified and as directed. |
| 42 | Excavation in post holes (or similar holes) in soft/loose soil, each not exceeding 0.50 cum and getting out, returning, filling in and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, including watering and removing surplus soil to a distance not exceeding 50m away from the starting point and making good surfaces complete all as specified and as directed. |
| 43 | M&L for PCC (1:3:6) type C-2, (using 40mm graded stone aggregate) as in foundation, mass fillings for posts/struts etc. complete all as specified and as directed. |
| 44 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed. |
| 45 | Supply and fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel roof sheet 0.50 mm thick of an colour having tensile strength of 550mpa fixed with self drilling screws complete all as specified and as directed. |
| 46 | Material and labour for preparation of steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 47 | Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat and curved surface including borders over metal frame work and reinforced with G.I. wire mesh including all fittings complete all as specified and as directed. |
| 48 | S&F rotational moulded polyethylene water storage tank 1000 ltr capacity three layered white colour (cylinderical vertical with closed top) hoisted and fixed in postion with unions, tank nipple and other fittings complete all as specified and as directed. |
| 49 | S&F 20mm size ball valve brass high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 50 | Surface excavation n exc 30cm deep and averaging 15cm deep in soft/loose soil complete all as specified and as directed. |
| 51 | Materials and labour for broken stone or boulder hard core of gauge n.exc 63mm deposited, spread and leveled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 52 | M&L for 100mm thick cement concrete (1:3:6) type C-2 (using 20mm graded stone aggregates) as in sub base of flooring complete all as specified and as directed. |
| 53 | M&L for 30mm thick sand cushion, filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 54 | M&L for laying 60mm thick machine pressed precast concrete interlocking paver block and shape and size conforming to IS -15658-2006 of M-35 grade with grey cement and pigment complete all as specified and as directed. NOTE:- The sample shall be got approved from the GE before bulk procurement and lots shall be got tested independently by the GE. |
| 55 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone agregete) as in sides of rounded or chamfered on edges of interlocking tiles complete all as specified and as directed. |
| 56 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody or for taking credit and making good to disturbed surfaces of walls, floors, etc. complete all as per specified and directed by Engr-in-Charge. |
| 57 | Taking down ceiling fan/exhaust fan of any size and sweep in proper manner and hanging after execution of point wiring in proper manner and connecting up including provision of cable from ceiling rose or connector to fan complete all as per specified and as directed by Engr-in-Charge. |
| 58 | Dismantling unserviceable main switch/DBs with MCBs and wooden board including making good to ndisturbed surface of wall complete all as per specified and as directed by Engr-in-Charge. |
| 59 | Taking down sub main wiring of any size/capacity and making good to disturbed sufaces to match with the existing surfaces complete all as specified and as directed. |
| 60 | M&L for modular point wiring with 1.5 sqmm (nominal area) 1100 Volts grade PVC insulated unsheathed multi stranded FRLSH multi stranded copper conductor cable, drawing through and including non metallic PVC rigid conduit medium grade, concealed in wall/ceiling/fixed to roof for one light or fan or bell point or socket out let controlled by one switch or push button or two way switch along with PVC insulated multi stranded copper conductor FRLSH cable 1.5 sqmm for earth continuity conductor and connected to earth dolly including fixing of GI flush mounting box of suitable module and suitable inner plate and modular plate of suitable size. The modular plate shall be flushed to wall, fixed with SS screw, complete including necessary chase cutting and making good disturbed surfaces complete all as specified and as directed. Note:- Metal flush box and white cover plate with frame as required on site shall be deemed to be included in unit rates. |
| 61 | (b) One Fan point controlled by one switch complete all as specified and as directed. |
| 62 | (c) One switch socket out let point 6 Amps on same board complete all as specified and as directed. |
| 63 | (d) One switch socket out let point 6 Amps on independent board complete all as specified and as directed. |
| 64 | M&L for modular point wiring with 2.5 sqmm (nominal area) 1100 Volts grade PVC insulated unsheathed multi stranded FRLS multi stranded copper conductor cable, drawing through and including non metallic PVC rigid conduit medium grade, concealed in wall/ceiling/fixed to roof for 15 Amps switch socket outlet controlled by one switch along with PVC insulated multi stranded copper conductor cable 2.5 sqmm for earth continuity conductor and connected to earth dolly including fixing of GI flush mounting box of suitable module and suitable inner plate and with modular plate of suitable size. The modular plate shall be flushed to wall, fixed with SS/cadmium plated screw, complete all as specified and as directed. Note:- Metal flush box and white cover plate with frame as required on site shall be deemed to be included in unit rates. |
| 65 | M&L for modular point wiring with 4.0 sqmm (nominal area) 1100 Volts grade PVC insulated unsheathed multi stranded FRLS multi stranded copper conductor cable, drawing through and including non metallic PVC rigid conduit medium grade, concealed in wall/ceiling/fixed to roof for 15 Amps switch socket outlet controlled by one switch along with PVC insulated multi stranded copper conductor cable 4.0 sqmm for earth continuity conductor and connected to earth dolly including fixing of GI flush mounting box of suitable module and suitable inner plate and with modular plate of suitable size. The modular plate shall be flushed to wall, fixed with SS/cadmium plated screw, complete all as specified and as directed. Note:- Metal flush box and white cover plate with frame as required on site shall be deemed to be included in unit rates. |
| 66 | M& L for modular bell push 6A one module complete all as specified and as directed. |
| 67 | M& L for modular switch 220 volts 1 way 16A one module complete all as specified and as directed. |
| 68 | M&L for modular type 220 volts 6A- 2/3 pin combined universal multi pin socket outlet 2 module complete all as specified and as directed. |
| 69 | M& L for modular type 220 volts 6/16A - 2/3 pin combined universal multi pin socket outlet 2 module .Make :Anchor (woods)/ Havells (Crabtree) /Legrand (Mosaic) |
| 70 | M&L for single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB for geyser and AC complete all as specified and as directed. |
| 71 | M&L for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified as directed. |
| 72 | M&L for fan step regulator, 120W - 2 module, complete all as specified as directed. |
| 73 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 74 | Supply and fixing LED lights fitting 1 x 20 Watt, 220Volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 75 | Supply and fixing 7 watt focus light 220 volts AC hanging type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for museum including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 76 | Supply and fixing 7W per metre LED flexible strip (5 Mtr bundle), IP 65 rated, outdoor type , 220V, of colour white, warm white, natural white, blue including, external driver if required, DMX controller if required, amplifiers if required, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 77 | Supply and fixing LED luminaire 600mm x 600mm, 36 watt, 220 V AC surface/recessed mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof/ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 78 | Supply and fixing ceiling fans complete with blades, down rods, modular electronic regulator and accessories, 230 V, 1200mm sweep or 48\\". Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper conductor cable of suitable size from ceiling, complete all as specified as directed. |
| 79 | M&L for submain wiring alongwith earth wire of size 2x 1.5 sqmm + 1x 1.5 sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor, single core cable drawn in and including PVC concealed conduit ISI marked, medium grade of adequate size with all conduit accessories medium grade ISI marked as required as specified and as directed. Note:- (i) Two runs of PVC main wire, one run of earth wire and 1 run of conduit shall be measured as one length. |
| 80 | Description same as per ser item No. 79.00 above but 2 x 2.5 sqmm + 1 x 2.5 sqmm complete all as specified and as directed. |
| 81 | Description same as per ser item No. 79.00 above but 2 x 4.0 sqmm + 1 x 4.0 sqmm complete all as specified and as directed. |
| 82 | Description same as per ser item No. 79.00 above but 2 x 6.0 sqmm + 1 x 6.0 sqmm complete all as specified and as directed. |
| 83 | S&F DB with sheet metal enclosure 240 volts, 12 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and as directed. |
| 84 | S&F DB with sheet metal enclosure 240 volts, 6 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and as directed. |
| 85 | Supply and fixing MCB rating 240V, 10 kA 'C' curve miniature circuit breaker (MCB) of SPN upto 32 Amps in the MCB DB complete all as specified and as directed. |
| 86 | Supply and fixing MCB rating 240V, 10 kA 'C' curve miniature circuit breaker (MCB) SP upto 32 Amps in the MCB DB complete all as specified and as directed. |
| 87 | M&L for earthing complete with galvanized steel earth plate electrode of size (600mm x 600mm) x 6mm thick buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts, nuts, check nuts and washers including earthing pit, charcoal, common salt, earthing lead 4.00mm dia up to 7.50m, 20mm dia medium grade GI watering pipe, GI protection pipe 15mm dia up to 7.50m long, PCC pit in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate), PCC pit cover including earth work in any type of soil/strata complete all as shown in electrical plate No. 3 and connected to earthing test point complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 19, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 30, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender