Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58462550

Tender For Addition/Alteration And Improvement To Bldgs Of 7 Asc At Chaf Banglaore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Nov 2026
15 days left
EMD
60907
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Addition/Alteration And Improvement To Bldgs Of 7 Asc At Chaf Banglaore

BOQ

Name of Work:- ADDN/ ALTN AND IMPROVEMENT TO BLDGS OF 7 ASC AT CHAF BANGLAORE
Sl. No. Item Description
1Dismantling floor hearth or wall tiling including cement mortar bedding and backing coat plastering of any thckness removing serviceable tiles to store and rubbish off premises etc., complete all as specified and as directed
2Material and labour for double charged virified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and as directed
3All as per item No.02 here-in-before but in Skirtings etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 10mm thick screed bed or bedding in CM 1:3 complete all as specified and as directed
4Material and labour for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and as directed
5Material and labour for glazed ceramic coloured tiles of size 350x250x7mm/ 450x350x7mm thick thick as vertical surface set and jointed in neat cement slurry and pointed in white or colour cement mixed with pigment to match the shade of the tiles laid over 10mm rendering 1:3 for laying wall finishes complete all as specified and as directed
6Supply and fix for non-skid (rough) endura heavy duty tiles of 10/ 12mm thick of approved size and shape and colour with minimum flexural strength of 38 N/mm2 in floors, staircase, apporons etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and as directed
7Material and labour for 25mm thick cement concrete type B-1, 1:2:4 (Using 20mm graded stone aggregate) in sub floors and finishing cement concrete surface even and rough complete all as specified and as directed
8Demolition of unreinforced cement concrete in floors and pavings not exc 15cm thick below or above ground level complete all as specified and as directed
9Taking down cement or cement lime plaster any description on brick or stone walls, over RCC slab, ceiling etc., including raking out joints, hacking for key, scrubbing down with water, etc., including necessary scaffolding complete all as specified and as directed
10Material and labour for rendering 15mm thick on fair faces of brick works/ block works or concrete surfaces cement plaster 1:6 finished even and smooth without using extra cement complete all as specified and as directed
11Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper through mechanical means over a coat of 1mm thick wall care putty complete all as specified and as directed
12Material and labour for complete removal of existing treatment on wall surfaces and appling two coats of distemper oil emulsion through mechanical means over a coat of 1mm thick wall care putty complete all as specified and as directed
13Material and labour for complete removal of existing treatment on ceiling surfaces and appling two coats of distemper oil emulsion through mechanical means over a coat of 1mm thick wall care putty complete all as specified and as directed
14Taking up or down 15mm bore steel tubing /CPVC pipes and connections, fittings etc., including cleaning for refixing or removal to store complete all as specified and as directed
15Taking up or down 20mm bore steel tubing/ CPVC pipes and connections, fittings etc., including cleaning for refixing or removal to store complete all as specified and as directed
16Cutting chases pinning in making good for stone concete block or slab walls to facing where required and pointing in cement mortar 1:3 to ends or edges of concealed water tubing and similar work including making good cutting not exc 10cm girth complete all as specified and as directed
17Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings 20mm outer diameter on walls/ ceiling or laying in floors or fixing as in concealed to walls or in floors etc., and making good the surfaces matching to existing surfaces of walls/ floor complete all as specified and as directed
18Supply and fix in repairs vitreous china wash basin, white flat back, size 550x400mm including cutting for and pinning in ends of brackets or easing stand waste pipe and coupling complete all as specified and as directed
19Supply and fix in repairs 15mm pillar tap, cast copper alloy, with capstan head, chromium plated, fancy type screwed down high pressure, with or without lettered \\"hot\\" or \\"cold\\" with long screwed shank and fly nuts screwed for iron pipe complete all as specified and as directed
20Supply and fix in repairs vitreous china wash down water closet pan (pedestal pattern), white with 'P' or 'S' trap, including provision of fixing bolts and connecting upto drain and flushing pipe etc., complete all as specified and as directed
21Supply and fix in repairs plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed
22Supply and fix in repairs PVC flushing cistern with flush out valve type,10 ltrs capacity, low level white with inlet ball valve, float and handle including bracket including flush pipe complete all as specified and as directed
23Supply and fix in repair PVC connection pipe 450mm long 15mm dia both end having brass coupling nuts and PVC washer complete all as specified and as directed
24Supply and fix in repairs heath faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed
25Supply and fix in repairs 15mm bore bib taps, fancy type with chromium plated with crutch or butterfly hadle screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed
26Supply and fix in repairs 15mm bore fancy type chromium plated two in one bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
27Supply and fix in repairs 15mm bore fancy type, chromium plated stop valves /angle cock screwed down high pressure with crutch handle screwed both ends for iron pipe or for unions complete all as specified and as directed
28Supply and fix in repairs 15mm bore fancy type, chromium plated with long shunk and cup (concealed type) stop valves screwed down high pressure with crutch handle screwed both ends for iron pipe or for unions complete all as specified and as directed
29Supply and fix in repair brass chromium plated fancy type towel rail, 20mm dia, D type 600mm long between flanges including brass CP brackets complete all as specified and as directed
30Supply and fix in repairs looking mirror of selected quality glass 600x450mm size with bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and as directed
31Supply and fix in repair bathroom cabinet mirror of moulded PVC of size 431.80x355.60mm including fixing to wall complete all as specified and as directed
32Supply and fix in repairs CP soap tray fixed to wall with chromium plated brackets /screws complete all as specified and as directed
33Supply and fix in repairs sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed
34Supply and fix in repairs PVC (SWR) pipes single socketed 110mm bore in any length with rubber ring joints fixed to walls complete all as specified and as directed
35Supply and fix in repairs PVC (SWR) pipes single socketed 110mm bore in any length with rubber ring joints laid in floor complete all as specified and as directed
36Supply and fix in repairs PVC (SWR) bend with access door 110mm bore complete all as specified and as directed
37Supply and fix in repairs PVC (SWR) bend 110mm bore complete all as specified and as directed
38Supply and fix in repairs PVC (SWR) branch piece single (Single Y) equal or unequal with access door 110mm bore complete all as specified and as directed
39Supply and fix in repairs PVC (SWR) 110mm bore vent cowl complete all as specified and as directed
40Supply and fix in repair PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and as directed
41Supply and fix in repairs PVC (SWR) pipes single socketed 75mm bore in any length with rubber ring joints fixed to walls complete all as specified and as directed
42Supply and fix in repairs PVC (SWR) pipes single socketed 75mm bore in any length with rubber ring joints laid in floors complete all as specified and as directed
43Supply and fix in repairs PVC (SWR) 75mm bore bends any radius with access door complete all as specified and as directed
44Supply and fix in repairs PVC (SWR) 75mm bore bends any radius complete all as specified and as directed
45Supply and fix in repairs PVC (SWR) branch piece single (Single Y) equal or unequal with access door 75mm bore complete all as specified and as directed
46Supply and fix in repairs PVC (SWR) junction single (Single T) equal or unequal with access door 75mm bore complete all as specified and as directed
47Cutting holes into or through stone walls superficial area not exc 150 sqcm built in, cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete complete all as specified and as directed
48Taking down chowkhats or frames exc 1.5 sqm but not exc 4 sqm with shutter (without taking of shutter from the frames) including taking out hold fasts and PCC bed block complete all as specified and as directed
49Forming jambs,with cement mortar 1:6 etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified and as directed
50Providing and fixing factory made uPVC white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and as directedNotes: (i) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.(ii) Area not exc 2.00 sqm each.
51Supply and fix for 5.5mm thick sheet glass, ordinary quality in square not exc 0.5 sqm in each pane complete all as specified and as directed
52Supply and fix for anodised aluminium grill (anodised transparent or dry required shed according to IS:1868 with minimum anodic coating of grade AC15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass /stainless steel screws @ 200mm centre to centre, including cutting to grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed
53Material and labour for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
54Supply and fix for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc., Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed
55Supply and fix for anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc., complete all as specified and as directed
56Supply and fix for 12mm prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations complete all as specified and as directed
57Dismantling any type wall and ceiling boards (fibre, pulp, insulation etc.,) or insulation boards /slabs/ bankets any thickness including cover fillets complete all as specified and as directed
58Supply and fix for armstrong 9mm PVC laminated gypsum board false ceiling of 600x600mm with prelude 24x3x300mm main tee and 24x27x1200mm cross tee and 24x25x600mm cross tee and wall angle of 19x19x300mm in false ceiling complete all as specified and as directed
59Supply and fix for PVC wall lining consisting of 5mm thick plain colour PVC sheet but single side prelam PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed
60Supply and fix for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall to make PVC frame complete all as specified and as directed
61Excavation in post holes each not exc 0.50 cum in any type of soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and as directed
62Material and labour for plain cement concrete 1:4:8, type D2 (Using 40mm graded graded stone aggregate) as foundation filling and mass concrete complete all as specified and as directed
63Supply and fix for structural steel work in tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed
64Supply and fix for rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde- E- 250) quality-A complete all as specified and as directed
65Supply and fix for prepainted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed
66Supply and fix for prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /ridge/ gutter /cladding, fixed with self tapping screws complete all as specified and as directed
67Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
68Demolition brick work or stone/ boulder /block masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed
69Removing demolished material i.e., building material concrete debris of any type etc., to a distance of 09 KM beyond and upto 10 KM out of premises of metropolition area including loading, unloading by manually or by mechanical means (JCB and to be transported through trolly or tipper) and staking at the destination complete all as specified and as directed
70Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board, light fittings, terminal boxes etc., removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed
71Material and labour for point wiring concealed type with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, including metal flush box of 1.60mm thick suitable for modular switches/ sockets/ fan regulators including modular white cover plate and modular metal flush box with frame of required modules at site, blanking plates, brass screws, cup washers etc., including all cutting /chases etc., in stone/ brick masonary/ walls, pinning in stone walls /brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc., for concealed conduit wiring using heavy duty stone drilling/ cutter machine and making good to the disturbed surfaces to match the existing surface of wall/ ceiling complete all as specified and as directed by Engr-in-charge for the following:-
72One light point controlled by one, one way switch 06 Amps.
73One ceiling /wall fan point controlled by one, one way switch 06 Amps.
74One exhaust fan point controlled by one, one way switch 06 Amps.
75One 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
76One 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
77One bell point controlled by one push button 5 Amps switch on independent board.
78All as per item No.71 here-in-before but point wiring with 2.5 sqmm single core FRLS cables and earth continuity wire of 2.5 sqmm single core FRLS cable for one 3 pin 15 Amps socket outlet point controlled by one, one way switch on independent board complete all as specified and as directedNote for item Nos. 71 to 72: Cutting into or through the stone walls /brick walls built in cement mortar or cement lime mortar and walls of cement concrete suitable size for housing for sunk box using heavy duty stone drilling/ cutter machine and making good the disturbed surface shall be measured and paid separately under relevant item No. 81.00)
79Supply and fix for modular switch, 6 Amps, single pole, one way, 230 volts, one module complete all as specified and as directed
80Supply and fix for modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete all as specified and as directed
81Supply and fix for modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified and as directed
82Supply and fix for modular socket outlet 02 in 01, 03 pin, 16 Amps, 02 module with shutter complete all as specified and as directed
83Supply and fix for modular bell push 6 Amps, one module 240 volts complete all as specified and as directed
84Supply and fix for ding dong bell, AC, 230 volts, single pole incl connection complete all as specified and as directed
85Supply and fix for ceiling rose, 65x50mm surface type with 3 terminals incl connection complete all as specified and as directed
86Supply and fix for ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts complete all as specified and as directed
87Cutting into or through the stone walls /brick walls built in cement mortar or cement lime mortar and walls of cement concrete suitable size for housing for sunk box using heavy duty stone drilling/ cutter machine and making good the disturbed surface complete all as specified and as directed
88Supply and fix for on surface/ wall mounted LED batten, 20 watt, 230 V, AC, 4 feet, white /warm white, decorative box type with intigrated electronic drive and accessories including connection including taking down old/ unsv light fitting complete all as specified and as directed
89Supply and fix for on surface/ wall mounted LED batten, robust extruded aluminium housing and initigarated electronic drive 10 watt, 2 feet, with accessories including connection with 2 core flexible copper conductor cable of suitable size from ceiling rose incl taking down old/unsv light fitting complete all as specified and as directed
90Supply and fix for surface/ ceiling recessed mounted LED panel type of size 2 ft x 2 ft, 36 W, 230 V, white /warm white type complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling incl taking down old/unsv light fitting complete all as specified and as directed
91Supply and fix for wall mounted LED light fitting, decorative type, champagne gold /black /or as required as per sample suitable for 12 /15 W LED lamp B22 base with driver holder including lamp white /warm white incl connection incl taking down old/unsv light fitting complete all as specified and as directed
92Supply and fix for wall surface mounted for spot/ picture LED light 10 watt, 220 volts, AC, high efficiency reflector with drivers, holders, lamp suitable for picture light including connection incl taking down old/unsv light fitting complete all as specified and as directed
93Supply and fix for surface mounted round LED down lighter, 12 watt, 220 volts, AC, designed with aluminium pressure die cast housing finished with epoxy powder coated white to deliver high efficiancy light and good uniformity, fitting to be fitted in the suface ceiling incl connection complete all as specified and as directed
94Disconnection and taking down old/ unsv/ faulty fan any type /size and depositing to MES store complete all as specified and as directed
95Supply and fix for ceiling fan complete with three blades, down rod, accessories 230 V, 1200mm sweep, min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) incl connection complete all as specified and as directed
96Supply and fix for wall mounting fan 400mm sweep, 1350 RPM, adjustable, plastic blade grill for protection, pull cord control for speed and oscillation on-off, incl connection complete all as specified and as directed
97Supply and fix for exhaust fan, 300mm sweep, steel body, heavy duty , AC single phase, 230 V with blades, and frame and louvers shutters incl making hole of required size in the wall with necessary civil/ cutting/ plywood wk/ plastering work all as required for proper fixing of fan in window/ wall and matching of surface with existing surface complete all as specified and as directed
98Supply and fix for fresh air ventilating fan 230/ 250mm sweep, 230V, AC, sturdy engineering plastic body with louver shutter etc., complete and connection from ceiling rose to fan terminal incl taking down old /unsv fan complete all as specified and as directed
99Material and labour for making necessary arrangement for fixing of exhaust fan/ air ventilating fan any size in window/ wall in proper alignment incl cutting /alteration of window /wall of any type (aluminium /steel) as per size of exhaust fan incl provision of plywood of suitable size /thickness for covering the gap/ opening of window frame incl nut, bolts etc of suitable size as required, including painting of plywood with two coat of synthetic enemel paint in white colour over one coat of primer and matching of surface with existing surface complete all as specified and as directed
100Material and labour for sub main wiring with 2.5 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 2.5 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 20mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting /chasses, pinning etc., in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and as directedNote: One run of earth continuity conductor, one run of PVC conduit concealed in wall and two run of copper conductor together taken as one length for measuring unit length.
101Material and labour for sub main wiring with 6 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 6 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 20mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting /chasses, pinning etc., in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and as directedNote: One run of earth continuity conductor, one run of PVC conduit concealed in wall and two run of copper conductor together taken as one length for measuring unit length.
102Material and labour for sub main wiring with 10 sqmm nominal cross sectional area, two single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 20mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting /chasses, pinning etc., in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and as directedNote: One run of earth continuity conductor, one run of PVC conduit concealed in wall and two run of copper conductor together taken as one length for measuring unit length.
103Material and labour for sub main wiring with 10 sqmm nominal cross sectional area, 3 phase and neutral (4 runs) of 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 10 sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit not less than of 32mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting /chasses, pinning etc., in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing complete all as specified and as directedNote: One run of earth continuity conductor, one run of PVC conduit concealed in wall and four runs of copper conductor together taken as one length for measuring unit length.Note for sl item No 94 to 97: Chasses/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concealed sub main wiring shall be measured and paid separately under relevant item No.98.
104Cutting chasis, pinning in brick wall etc., making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc., for concealed conduit wiring into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25mm dia conduit pipe using heavy duty stone drilling /cutter machine and making good the disturbed surface complete all as specified and as directed
105Supply and fix for sheet metal enclosure with socket plug top and neutral enclosure with a two pin and earh plug and socket complete with one SPN MCB 20 Amps 'C' curve type, incl taking down old /unsv complete all as specified and as directed
106Supply and fix for VTPN sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal double door, IP 43 protection, suitable for MCCB 4 pole 125 Amps as incomer and MCB SPs/ SPN as outgoing along with cable end box for above DB and concealed flush in wall including all cutting chasses /civil work as required in stone/ brick masonary/ walls, pinning in stone walls /brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc incl connection and taking down old unsv DB complete all as specified and as directedNote: MCCB and MCB SPs /SPN will be measured and paid seperately.
107Supply and fix for sheet metal enclosure DB, single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs incl chases wall for fixing DB and making good to the disturbed surface incl taking down old/unsv DB complete all as specified and as directed by Engr-in-charge for the following No of ways:-
1088 way
10912 way
110Supply and fix for sheet metal enclosure, double door type for MCB TPN DB 4 way, vertical type, 415 volts with 200 Amps rated busbar and neutral link, chases wall for fixing DB and making good distributed wall surfaces to match with existing including taking down old/unsv DB complete all as specified and as directed
111Supply and fix for MCCB, 63 Amps, 4 Pole, 415 volt, AC, fixed type, suitable for load line/ VTPN DB/LT Panel and connection incl taking down old/unsv complete all as specified and as directed
112Supply and fix for MCB TPN, 63 Amps, 415 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs incl taking down old/unsv complete all as specified and as directed
113Supply and fix for MCB SPN, 63 Amps, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs incl taking down old/faulty MCB complete all as specified and as directed
114Supply and fix for MCB SP, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs incl taking down old/faulty MCB complete all as specified and as directed by Engr-in-charge for the following rating:-
11510 to 32 Amps
11640 Amps
117Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of complete all as specified and as directed by Engr-in-charge for the following nominal cross section area /sizes:-
11810 sqmm 2 core
11916 Sqmm 4 core
12035 Sqmm 3.5 core
121Material and labour for GI tubing, light grade with all necessary fittings laid in trenches/ under road crossing/ fixed on pole /wall /under floor including suitable mild steel FI clamps of required size for protection of LT UG cable complete all as specified and as directed by Engr-in-charge for the following sizes:-
12240mm bore
12350mm bore
124Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth, getting out for electric cable in any type of soil complete all as specified and as directed
125Removing surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above starting point complete all as specified and as directed
126Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed
127Supplying and laying un-reinforced precast concrete cable cover, class LV, type I, flat, size 250x150x40mm complete all as specified and as directed
128Material and labour for sand filling (pulverized stone dust) for sand cushioning incl spreading and levelling for protection of cable complete all as specified and as directedNote: Only punned thickness shall be measured for payment.
129Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised earth lead wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point or indiacted including testing on completion complete all as specified and as directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58462550
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 30-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Addition/Alteration And Improvement To Bldgs Of 7 Asc At Chaf Banglaore
Basic Detail
Tender No 8606/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 09 Nov 2026
Submission Date 30 Nov 2026
Open Date 02 Dec 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 60907
Exemption Available
Document List
9246902e-f1c3-4526-905b-a17fcc267726.html
BOQ_895162.xls
SOC8606.pdf
Tenderdocuments8606.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

9246902e-f1c3-4526-905b-a17fcc267726.html

xls

BOQ_895162.xls

pdf

SOC8606.pdf

pdf

Tenderdocuments8606.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender