Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #58462365

Tender For Providing Of Toilets In Certain Locations At 23 Ed Under Ge Avadi

Issued by Statutory Bodies & Commissions/Committees · Thiruvallur, Tamil Nadu
Tender Value
29.15 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
7 days left
EMD
58300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing Of Toilets In Certain Locations At 23 Ed Under Ge Avadi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Corrigendum - 1 Other 28-Nov-2026

BOQ

Name of Work:- PROVN OF TOILETS IN CERTAIN LOCATIONS AT 23 ED UNDER GE AVADI
Sl. No. Item Description
1B/R Portion
2Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soile complete.
3Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete in soft/loose soil.
4M & L for PCC(1:4:8) type D-2 (40 mm graded aggregate) as in foundation, filling & Mass concrete as directed by Engr-in Charge
5M&L for Old size Brick work with flyash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.
6M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 all as specified and directed.
7M&L for PCC 1:4:8 type D-2,(using 40 mm graded aggregate) 100 mm thick as in sub base to receive floor finishes etc complete all as specified.
8M&L for 100 mm thick PCC 1:2:4 type B1 (using 20 mm graded granite stone aggregate) inpavings all as specified.
9M & L for reinforced cement concrete( RCC) type 1:2:4 type B-1 (20mm graded aggregate) as in slab supported on wall, beam and columns in floors,roofs,landing,blaconies,canopies,deck slab and in shelves and the like complete all as specified and directed.
10M&L for formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc.
11M&L Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
12M & L Mild steel bars 8mm dia and over as in stirrups cut to length, bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
13M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete.
14M/L for Hard core of guage not exc 63mm with broken stone deposited spread & levelled in layers n.exc 15cm thick, watered & ramed to a true surface complete all as specified and directed.
15M&L for 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 (finished even and fair) , complete complete all as specified and directed.
16M&L 20 mm thick rendering ( in two coats 10mm+10mm) on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and fair mixed with integral water proofing compound @ 2% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
17Supply only integral Water proofing compound all as specified and directed.
18M&L for two coats of oil bound distemper over a coat of priming coat on newly prepared wall surfaces,including 1 mm thick layer of wall care putty (Birla white or equivalent) all as specified and directed..
19M&L of new plastered or unplastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
20M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
21M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces of tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
22S&F for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
23S&F for Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
24S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
25S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing all as specified and directed.
26S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
27S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section complete all as specified and directed.
28S&F 150 mm size Aluminium handles, cast type, anodised complete all as specified and directed.
29S&F 100 mm size butt hinges, medium weight , cold rolled, mild steel complete all as specified and directed
30Supplying and laying 16 mm dia of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
31Supplying and laying 20 mm dia of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
32Supplying and laying 25 mm dia of CPVC pipes SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
33M&L for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded crushed stone agg as in plinth protection/ path laid slope of 1 in 12 and finshing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges or as directed by engr -in-charge.
34S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
35S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed.
36S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed.
37S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified.
38S&F in repair 15 mm bore PVC connection 600 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed.
39S&F 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
40S&F angle , stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
41S&F brass chromium plated tubular towel rail of 20 mm dia D' type 60cm long between flanges complete all as specified and directed.
42S&F Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and directed
43S&F 600 mm x 450 mm beveled edge mirror of selected quality glass 5.5mm thick mounted on 6 mm thick AC building board or commercial plywood & fixed with wooden plugs with chromium plated brass screws and washer and aluminum beading complete all as directed by Engr-in-Charge. Make:COMMANDER PATTERN / (MANGOLD)/ JASMINE/ GOLDEN FISH or equivalent as approved by GE.
44S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
45S&F for structural steel work as in roof trusses (framed), trussed, purlins, framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed.
46S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugation, 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed by Engr-in-Charge.
47S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) (500 ltr) hoisted and fixed in position all as specified and directed.
48M&L 20 mm Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
49M&L chequerred tiles 20 cm x20 cm x25mm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors over 20 mm thick screed bed in CM 1:4 bedded and jointed in gray cement slurry with pigment all as specified and directed.
50M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
51M & L for On site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 05 Users.
52Soakage wells size 1.2m dia and 3m effective depth for excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size.
53M & L for PCC 1:3:6 type C-2 as in Concrete bed to drain pipes 110 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested; in all as specified and directed.
54S & F PVC (SWR) pipe 110 mm bore drain pipe single socketed in any length with rubber ring joint fixed to wall (ISI Marked) all as specified and as directed.
55S & F PVC (SWR) pipe 75mm bore single socketed in any length with rubber ring joint fixed to wall (ISI Marked) all as specified and as directed.
56S&F PVC ( SWR ) bends 110 mm bore all as specified and directed.
57S&F PVC ( SWR ) bends 75 mm bore all as specified and directed.
58M & L RCC NP3 150 mm diameter Pipes laid on150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional.
59Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in loose/soft soil complete.
60Removing excavated material n.exc 50 m and deposited where directed at level n.exc 1.50m directed at a level n.exc 1.50m above the starting point.
61PART - II - E/M PORTION
62Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc., complete all as specified and as directed.
63M & L for point wiring with two runs of 1.5 Sqmm (nominal area) PVC insulated,FRLSH sheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for :-(a) One light point controlled by one switch.
64(b) One Ceiling fan point controlled by one switch and regulator
65(c) One Exhaust fan/wall mounted fan point controlled by one switch.
66(d) One 3 pin 5 amps socket point on same board
67(e) One 3 pin 5 amps socket point on independent board
68(f) One bell / buzzer point controlled by one bell push
69M & L for point wiring with two runs of 4 Sqmm (nominal area) PVC insulated,FRLSH sheathed, multistrand, 1100 volts grade copper conductor cable single core, drawn through with and including non metallic PVC conduit 20/25mm dia and its accessories fixing on wall/ceiling/trusses with suitable clamps , screws etc including one run of 4 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing, 1.6 mm thick MS terminal box finished to wall with 3 mm thick laminated hylam sheet top cover all as specified for One 5 pin 5/15 amps socket point on independent board complete all as specified.
70Taking down carefully unserviceable Power / Sub main wirings with PVC aluminum conductor cables in PVC/STEEL conduits / TW battens up to 2 runs of 6 Sq.mm removing materials from site, taken as credit , making good the disturbed surfaces all as specified and as directed.
71M&L for wiring for circuit / power /sub main wire with two runs of single core 4 Sqmm size and one run of 4 Sqmm (green colour as earth continuity conductor) PVC insulated, unsheathed, multi stranded copper conductor FRLSH cable drawn through including suitable dia PVC conduit concealed in wall and fixing arrangement on ceiling/trusses with suitable clamps,screws etc complete with accessories all as specified.
72M&L for wiring for circuit / power /sub main wire with two runs of single core 6 Sqmm size and one run of 6 Sqmm (green colour as earth continuity conductor) PVC insulated, sheathed, multi stranded copper conductor FRLSH cable drawn through including suitable dia PVC conduit concealed in wall and fixing arrangement on ceiling/trusses with suitable clamps,screws etc complete with accessories all as specified.
73M&L for wiring for circuit / power /sub main wire with two runs of single core 10 Sqmm size and one run of 10 Sqmm (green colour as earth continuity conductor) PVC insulated, sheathed, multi stranded copper conductor FRLSH cable drawn through including suitable dia PVC conduit concealed in wall and fixing arrangement on ceiling/trusses with suitable clamps,screws etc complete with accessories all as specified.
74S&F Switch piano flush type, single pole,5 Amps complete all specified.
75S&F Switch socket 3 pin 5 amps , multi pin , flush type,complete all specified.
76S&F Switch socket 3 pin 16 Amps, multipurpose, flush type complete all specified.
77S&F Bell push, flush type, single pole, 5 Amps, 240 volts complete all specified.
78Supply and Fixing Modular switch 1 way 6A, 1 module complete all as specified.
79Supply and Fixing Modular switch 1 way16A, 1 module complete all as specified.
80Supply and Fixing Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified.
81Supply and Fixing Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified.
82S&F ceiling rose 65 X 50 mm , three terminals ,bakelite , surface complete all specified.
83S&F in replacement of Single Pole Neutral Enclosure with a Two pin and Earth plug and socket complete with one single pole MCB 20A complete all as specified and directed.(For Acs)
84Supply and fix in replacement Bell Ding dong 230V,50 Hz complete all as specified and as directed.
85Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.(MCB for SPN DB)
86Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole Neutral and current carrying capacity 32-63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.(MCB for VTPN DB)
87Supply and fixing MCCB 3 Pole, 415 V, 25-100 Amps with breaking capacity 16 KA complete all as specified.
88Supply and fixing MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 16 KA complete all as specified.
89Supply and fixing MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified.
90S&F MCB DB SPN 4 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
91S&F MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
92S&F MCB DB SPN 12 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
93S&F in replacement of MCB DB TPN 4 way, distribution DB double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for TPN MCB 63 Amps as incomer and SP MCBs 40 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCB and Outgoing MCB measured separately relevent items.
94S&F Load line vertical distribution Board, TPN 4way double door, fixed on wall semi flush, loadline DB are fitted with Bus bars, neutral links, blanking plates, including incommer MCCB 100/125 Amps,TP and suitable outgoing MCB 40 /63Amps,SP/DP/TPN with all accessories suitable for DB including taking down old unserviceable DB all as specified and as directed. Note : Incoming MCCB and Out going MCBs measured seperately relevent items.
95S&F Load line vertical distribution Board, TPN 8 way double door, fixed on wall semi flush, loadline DB are fitted with Bus bars, neutral links, blanking plates, including incommer MCCB 100/125 Amps,TP and suitable outgoing MCB 40 /63Amps,SP/DP/TPN with all accessories suitable for DB including taking down old unserviceable DB all as specified and as directed. Note : Incoming MCCB and Out going MCBs measured seperately relevent items.
96Supply and fixing in replacement of LED tube light fitting with polycarbonate LED tube light 20W 4 feet and 1 x 20 watt box type batten aluminum body with microwave motion technology and integrated electronic driver including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
97S&F Surface and wall mounted LED tube light fitting 2 Feet long, 10 W, batten type, PC housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete with all accessories , suitable for operation on AC, single phase 220 / 230 Volts , 50 Hz supply, and including connecting up with PVC sheathed suitable copper conductor flexible wire from ceiling rose to fitting complete all as specified and as directed.
98S&F LED Panel light recessed 30/32 watt (2 x2 ),white powder coated CRCA full glow recess mounting LED Backlit Panel, integrated electronic driver complete including connection from ceiling rose to light fitting with twin core cable 23/0.0076 Sqmm complete all as directed.
99Taking down the old unsv BER ceiling fan/ Exhaust Fan and deposit in MES store yard with down rods complete all as specified and as directed.
100Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor with five star rating.
101Supply and Fixing Modular fan step regulator , 120w, 2 module complete all as specified.
102Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting.
103Supply and fix Heavy Duty Pedestal Fan with Metal body , complete with three metal blade and accessories with specifications 230V,180W, 450mm Sweep, 1440RPM and Copper wiring all as specified and directed.
104S & F Ventilation fan 200mm sweep, Power 22 W, Operating voltage 230 Volts with louvers and shutters plastic body type, with necessary civil work, alteration in exist ventilation window of iron/aluminium frame for fixing of fan as per site requirement complete make good the wall/ventilation window match with exist complete with all accessories and connecting up with suitable size 1 sqmm three core copper conductor flexible wire,screws,gutties complete
105M&L for making hole for fixing of exhaust/ventilation fan size 300 mm with necessary civil work as per site requirement complete make good the wall/ventilation window match with exist complete all as specified and directed.
106Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
107Material and labour for GI earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58462365
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.15 Lakhs
LAST DATE 28-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of Toilets In Certain Locations At 23 Ed Under Ge Avadi
Basic Detail
Tender No 8451/E8
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 12 Nov 2026
Submission Date 28 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 29.15 Lakhs
Tender Fee 500
EMD 58300
Exemption Available
Document List
8451TENDERDOCUMENTS.pdf
BOQ_895087.xls
c22bcf2a-3612-4cf0-93d8-ce026408022d.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Nov 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

8451TENDERDOCUMENTS.pdf

xls

BOQ_895087.xls

html

c22bcf2a-3612-4cf0-93d8-ce026408022d.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender