Coal and Mines Boards / Undertakings / PSU Closing in 6 days TDR #58449923

Tender For Installation Of Substation Transformer 100Kva, 11Kv/440V And 100Kva, 3.3Kv/440V Along With Grid Earthing, Lightning Arrestor And 440V Control Panel For Power Distribution With Fixing Of Mccb, Earth Protection And Earth Leakage Relay For Sy

Issued by Boards / Undertakings / PSU · Ranchi, Jharkhand
Tender Value
55.39 Lakhs
Estimated cost
Bid Submission
25 Nov 2026
6 days left
EMD
69300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Installation Of Substation Transformer 100Kva, 11Kv/440V And 100Kva, 3.3Kv/440V Along With Grid Earthing, Lightning Arrestor And 440V Control Panel For Power Distribution With Fixing Of Mccb, Earth Protection And Earth Leakage Relay For Systematic And Sufficient Power Supply With Required Accessories At 2X3mva, 11Kv/440V Main Substation And Rohini Digital Dispensary/ P.O Office Switching Station Under Rohini Ocp And Dismantle, Erection Of Poles With Installation Of Lightning Arrestor, Goab Switch, Fuse Unit, Construction Of Grid Type Earthing Arrangements Along With Required Accessories And Making Of Substation Yard With Laying Of Gravels And Reconditioning Of Junction Box Lt Panel (440/220V) By Providing Diffrent Protective Divices Like 630A/400A Mccbs, Mcbs, Earth Fault, Earth Leakage Relays Along With Other Accessories For Restructing The Ohl Supplying Power To Diffrent Villages, Pit Office, Weighbridges, Workshop And Substation Yard In Quarry No. 01 Sub-Station Under Purnadih Ocp And Electrical Maintenance Of 33Kv, Feeder No. 5 And 6 Overhead Lines From Piparwar Switching Station And Maintenance Of Old Sub-Station (22.5Mva, 33Kv/3.3Kv) And New Sub-Station (15Mva, 33Kv/6.6Kv) For One Years Under Kdh Ocp, Nk Area.

BOQ

Name of Work:- Installation of Substation Transformer 100kVA, 11kV/440V and 100kVA, 3.3kV/440V along with grid earthing, lightning arrestor and 440V control panel for power distribution with fixing of MCCB, earth protection and earth leakage relay for systematic and sufficient power supply with required accessories at 2X3MVA, 11kV/440V Main Substation and Rohini Digital Dispensary/ P.O Office switching station under Rohini OCP and Dismantle, erection of poles with installation of lightning arrestor, GOAB switch, Fuse Unit, construction of grid type earthing arrangements along with required accessories and making of substation yard with laying of gravels and Reconditioning of Junction box LT Panel (440/220V) by providing diffrent protective divices like 630A/400A MCCBs, MCBs, Earth Fault, Earth Leakage Relays along with other accessories for restructing the OHL supplying power to diffrent villages, PIT Office, Weighbridges, Workshop and Substation Yard in Quarry No. 01 Sub-station under Purnadih OCP and Electrical Maintenance of 33kV, Feeder No. 5 and 6 overhead lines from Piparwar Switching station and Maintenance of old sub-station (22.5MVA, 33kV/3.3kV) and New sub-station (15MVA, 33kV/6.6kV) for one years under KDH OCP, NK Area.
Sl. No. Item Description
1Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
2Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 meter and upto 12.00 meter
3Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 meter and upto 6.5 meter
4Supplying and erection of galvanized stay set for 11KV overhead lines Complete with 19/20mm dia X 1.8 meters long stay rod, anchor plate of size 45cm X 45cm X 7.5mm thick, thimble, stay clamps, turn buckle (20 mm X 600mm), 7/4.00mm dia G.I. stay wire and 3.3 KV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
5Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per meter) double pole cross arm for three wire 11KV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc. (as per drawing) and painting with primer and finish paint as required.
6Erection of double pole 3 wire cross arm for 11KV/22KV/ 33KVoverhead lines as required.
7Supplying and erection of a set of cross bracing FRLS frame work for 3.3 KV overhead line double pole structure having four members fabricated out of 50mm X 50mm X 6mm angle iron to form a rectangle of minimum size 1400mm width X 2500 mm height, complete with 50mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. (as per drawing) and painting with primer and finish paint as required.
8Supplying and erection of 3.3 KV pin insulator complete with large steelhead G.I. pin, nuts, washers etc. as required.
9Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
10Supplying and erection of 11KV disc insulator for 3.3KV overhead lines with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required
11Supply of 7/16 SWG G.I wire for earth continuity.
12Supply of 8 SWG G.I. wire.
13Erection of G.I. Wire No. 8 SWG including binding etc. as required.
14Erection of cradle guard as required.
15Providing and fixing of 11kv, 800Amp. GOAB Isolator.
16Providing and fixing of Fuse Unit.
17Providing and fixing 630A 50kA rating and breaking capacity and pole MCCB thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
18Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
19Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil
20Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
21Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement :4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
22Brick work with common burnt clay F.P.S. (nonmodular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
23Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1cement :2coarse sand (zone-III) derived from natural sources:4 graded stone aggregate 20 mm nominal size derived from natural sources)
24Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40 mm thick with 20 mm nominal size stone aggregate
25Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1cement: 1.5 coarse sand (zone-III) derived from natural sources: 3graded stone aggregate 20mm nominal size derived.
2612 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand)
27Laying of one number additional PVC insulated and PVC sheathed XLPE power cable of 1.1KV grade of Upto 95 Sqm direct in ground in the same trench in one horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
28Providing and laying of approved gravels stone of 40mm nominal size of average thickness 100mm
29Providing of gland bush for transformers
30Providing of MCCB enclosure box 300x300x100mm box.
31Dismantling of 11kV, GOAB Isolator.
32Providing and fixing of GOAB switch 11kV, 630 Amp. 25kA, Triple pole, vertical load breaker IS9920 mounting with 11kV grade porcelain post insulator, vertical operating pipe, phase coupling pipe.
33Providing and fixing of GOAB switch 11kV, 630 Amp. 25kA, Triple pole, Double Break, horizontal upright mounting with 11kV grade porcelain post insulator, vertical operating pipe, phase coupling pipe.
34Providing and fixing of Fuse unit 11kV, 200 Amp. Triple pole, horizontal upright mounting with 11kV grade porcelain post insulator
35Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
36Providing and fixing 25 mm X 5 mm GI. Strip on surface or in recess for connections etc. as required.
37Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
38Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required.
39Providing and fixing 630 A, 50 KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
40Providing and fixing 400 A, 50 KA,FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
41Providing and fixing extended rotary handle for MCCB 630A and 400A kA including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
42Providing and fixing Digital Voltmeter, 3 Phase Aux Voltage- 90-220V including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
43Providing and fixing Digital Ammeter, 3 Phase Aux Voltage- 90-220V including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
44Providing and fixing MCB SP 6 Amp. 10 kA capacity including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
45Providing and fixing MCB DP 6 Amp. 10 kA capacity including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
46Providing and fixing Microprocessor based earth leakage relay sensitivity = 0.03 12A with CBCT capacity including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
47Providing and fixing Shunt Trip release, 220V AC for MCCB including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
48Providing and fixing Microprocessor based overcurrent and earth fault relay, Aux voltage 24V to 275V, AC/DC capacity including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
49Providing of Indicating LED Type Lamp for \\"R,Y,B, ON, OFF, TRIP\\" Indication supply volt -220V AC
50Providing and fixing Auxiliary contractor 2 NO + 2 NC, 220V including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
51Providing and fixing of Isolator pad connector for isolator to conductor.
52Providing of MCCB 250Amp. 4 pole.
53Providing of MCCB Box size – 800x120x300mm
54Providing and fixing of lightning arrestor.
55Providing of DMC/Epoxy electrical insulator with nut bolt and washers.
56Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand: 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc. as required.
57Pole painting two coats. (Aluminum paint)
58Providing and fixing of 50 mm x 6 mm G.I strip on surface or in recess for loop earthing as required.
59Welding of G.I strip to iron structures and switchgears body.
60Providing and fixing of GOAB switch 11kV, 630 Amp. 25kA, Triple pole, Double Break, horizontal upright mounting with 11kV grade porcelain post insulator, vertical operating pipe, phase coupling pipe including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
61Providing and fixing of Fuse unit 11kV, 200 Amp. Triple pole, horizontal upright mounting with 11kV grade porcelain post insulator including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
62Providing and fixing of aluminum cable 35 Sq.mm 3.5 core including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
63Providing and fixing of MCCB enclosure size 800x120x300mm including all material, labour, tools & tackles and plant all complete to the satisfaction of Engineer – in – charge.
64Disconnection and reconnection of conductors of jumper of 33kV of Feeder No. 5 & 6 OH lines for rectification of faults in these line as well as provision of power to old sub-station (22.5MVA, 33kV/3.3kV) and New sub-station (15MVA, 33kV/6.6kV).
65Cable handling (Lowering and lifting) of power cables for fault rectification/shifting of cables for different outgoing feeders from old sub-station (22.5MVA, 33kV/3.3kV) and New sub-station (15MVA, 33kV/6.6kV).
66Relocation / dismantling and re-erection of light fittings of Old and new sub-station.
67Repairing of cradle guards, earth wires or stay sets.
68Repairing of 33KV GOAB switches installed in old and new sub-station. (Providing and fixing of Fixed Contact 33KV 1250A 25KA Base 165x36x8mm Contact-70x30x6mm GI Cover-140X44mm Spring-06 Nos. AND Moving contact 33KV 1250A Base assemble- 170x40x8mm Moving- 290x25x4mm Bush-Bronze Metal, Thickness of Groove-11)
69Re-erection / tensioning of the conductors of HT OH lines for maintaining the proper sag as well as after fault clearing of HT OH Lines
70Branch / bush cutting under HT overhead line
71Erection of HT disc/ pin insulator for replacement of faulty insulator.
72Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58449923
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 55.39 Lakhs
LAST DATE 25-11-2026
Authority
Authority Name Central Coalfields Limited
Work Description Tender for Installation Of Substation Transformer 100Kva, 11Kv/440V And 100Kva, 3.3Kv/440V Along With Grid Earthing, Lightning Arrestor And 440V Control Panel For Power Distribution With Fixing Of Mccb, Earth Protection And Earth Leakage Relay For Systematic And Sufficient Power Supply With Required Accessories At 2X3mva, 11Kv/440V Main Substation And Rohini Digital Dispensary/ P.O Office Switching Station Under Rohini Ocp And Dismantle, Erection Of Poles With Installation Of Lightning Arrestor, Goab Switch, Fuse Unit, Construction Of Grid Type Earthing Arrangements Along With Required Accessories And Making Of Substation Yard With Laying Of Gravels And Reconditioning Of Junction Box Lt Panel (440/220V) By Providing Diffrent Protective Divices Like 630A/400A Mccbs, Mcbs, Earth Fault, Earth Leakage Relays Along With Other Accessories For Restructing The Ohl Supplying Power To Diffrent Villages, Pit Office, Weighbridges, Workshop And Substation Yard In Quarry No. 01 Sub-Station Under Purnadih Ocp And Electrical Maintenance Of 33Kv, Feeder No. 5 And 6 Overhead Lines From Piparwar Switching Station And Maintenance Of Old Sub-Station (22.5Mva, 33Kv/3.3Kv) And New Sub-Station (15Mva, 33Kv/6.6Kv) For One Years Under Kdh Ocp, Nk Area.
Basic Detail
Tender No GM (NK)/EnM/e-NIT/2026-27/107
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 09 Nov 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 55.39 Lakhs
Tender Fee Ref. Documents
EMD 69300
Exemption Not Available
Document List
BOQ_381506.xls
e60f6558-0f94-4b1c-96db-7d2e44939047.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_381506.xls

html

e60f6558-0f94-4b1c-96db-7d2e44939047.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender