Tender For Provn Of Cooling Appliances For Offrs, Jcos And Or Mess At Od Avadi Under Ge Avadi
Tender Value
33.91 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
6 days left
EMD
67820
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Cooling Appliances For Offrs, Jcos And Or Mess At Od Avadi Under Ge Avadi
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of high-wall split air conditioner of 1.5 TR capacity, complete with indoor and outdoor units, copper condenser coil, cordless remote control, inbuilt ioniser and plasma filter, suitable for operation on 230 V, single-phase, 50 Hz AC supply, with BEE 5-star rating under the applicable labelling period, complete, all as specified and directed. |
| 2 | S&F powder-coated GI bracket assembly fabricated from 16 SWG material for supporting the outdoor unit of a split air conditioner, including suitable anchor fasteners, grouting and fixing accessories, complete, all as specified and directed. |
| 3 | S&F automatic voltage stabiliser of 4 kVA capacity, single-phase, naturally air-cooled, indoor type, suitable for an input voltage range of 90–260 V and a stabilised output of 230 V with an accuracy of ±2.5%, complete with connections, testing and commissioning, all as specified and directed. |
| 4 | S&F refrigerant-grade copper tubing set comprising 6.35 mm (¼ inch) and 12.70 mm (½ inch) outside-diameter tubes for interconnecting the indoor and outdoor units of a split air conditioner, including PUF insulation, compatible fittings, jointing, supports and connection accessories, complete, all as specified and directed. |
| 5 | M&L for submain wiring comprising two runs of 4 sq mm PVC-insulated, unsheathed, single-core, multistranded copper conductor cable, 1,100 V grade, bearing the BIS Standard Mark, drawn through and including PVC conduit, conduit fittings and accessories, together with one run of 4 sq mm PVC-insulated copper earth-continuity conductor, including terminations, connection to the common earth terminal and taking down existing wiring, complete, all as specified and directed. |
| 6 | S&F 240 V, 20 A SPN enclosure complete with a two-pole-and-earth plug and socket and one 20 A single-pole MCB, including fixing, connections and testing, complete, all as specified and directed. |
| 7 | S&F PVC condensate drain pipe of 15 mm or 20 mm diameter, as specified for the respective indoor unit, including compatible fittings, supports and connections, laid to a continuous fall towards the designated discharge point, complete, all as specified and directed. |
| 8 | S&F single-pole MCB, 240 V, 10 kA breaking capacity, C-curve, of the specified current rating within the range of 6–32 A, suitable for installation in the 12-way SPN distribution board, including connections, testing and commissioning, complete, all as specified and directed. |
| 9 | M&L for point wiring for one 16 A, three-pin switched socket outlet on stone or brick masonry walls, comprising two runs of 4 sq mm PVC-insulated, FRLSH, unsheathed, single-core, multistranded copper conductor cable, 1,100 V grade, conforming to IS 694, drawn through and including rigid non-metallic PVC conduit of not less than 20 mm diameter, concealed in walls and surface-fixed to ceilings or roof trusses where required, including conduit fittings, accessories and suitable clamps; together with one run of 4 sq mm green PVC-insulated FRLSH copper earth-continuity conductor connected to the common earth terminal, including modular box, mounting frame, cover plate, cutting chases and making good disturbed surfaces, complete, all as specified and directed. Note: Modular switch and socket outlet shall be measured and paid for separately . |
| 10 | S&F modular switch, 16 A, one-way, single-module type, including fixing and connections, complete, all as specified and directed. |
| 11 | S&F modular combined socket outlet, 6/16 A, suitable for two-pin and three-pin plugs, two-module type, including fixing and connections, complete, all as specified and directed. |
| 12 | S&F automatic voltage stabiliser of 3 kVA capacity, single-phase, naturally air-cooled, indoor type, suitable for an input voltage range of 90–260 V and a stabilised output of 230 V with an accuracy of ±2.5%, complete with connections, testing and commissioning, all as specified and directed. |
| 13 | Supply, installation, testing and commissioning of self-contained, storage-type drinking water cooler, having a cooling capacity of not less than 60 litres per hour and a storage capacity of not less than 120 litres, with stainless steel storage tank and body, energy-efficient compressor using non-CFC refrigerant, two stainless steel dispensing taps and collection tray, suitable for operation on 230 V, single-phase, 50 Hz AC supply, conforming to the applicable Indian Standard, complete, all as specified and directed. |
| 14 | Supply, installation, testing and commissioning of double-door, frost-free refrigerator of capacity not less than 345 litres, with inverter compressor and BEE 5-star rating under the applicable labelling period, suitable for operation on 230 V, single-phase, 50 Hz AC supply, complete, all as specified and directed. |
| 15 | Supply, installation, testing and commissioning of double-door, frost-free refrigerator of capacity not less than 310 litres, with inverter compressor and BEE 5-star rating under the applicable labelling period, suitable for operation on 230 V, single-phase, 50 Hz AC supply, complete, all as specified and directed. |
| 16 | Supply, installation, testing and commissioning of double-door, frost-free refrigerator of capacity not less than 195 litres, with inverter compressor and BEE 5-star rating under the applicable labelling period, suitable for operation on 230 V, single-phase, 50 Hz AC supply, complete, all as specified and directed. |
| 17 | Supply, installation, testing and commissioning of metal-top deep freezer of 320-litre capacity, with inverter compressor and BEE 5-star rating under the applicable labelling period, suitable for operation on 240 V, single-phase, 50 Hz AC supply, complete, all as specified and directed. |
| 18 | M&L for PCC 1:2:4, type B-1, using 20 mm graded stone aggregate, in copings and pedestals for poles, including necessary formwork and finishing exposed surfaces even and fair, complete, all as specified and directed. |
| 19 | S&F 50 mm nominal-bore uPVC pipes, Schedule 80, laid in trenches, including compatible bends, tees, short lengths, connectors, elbows, reducers, unions, sockets and other necessary fittings, including taking down existing corroded pipework, jointing and testing, complete, all as specified and directed. |
| 20 | S&F 20 mm nominal-bore uPVC pipes, Schedule 80, concealed in walls, including compatible bends, tees, short lengths, connectors, elbows, reducers, unions, sockets and other necessary fittings; cutting chases and making good disturbed wall surfaces and finishes; forming the required opening in the existing overhead PVC water storage tank and providing a watertight connection using suitable tank fittings; including jointing and testing, complete, all as specified and directed. |
| 21 | S&F 15 mm bore brass chromium-plated stop valve, fancy type, high-pressure, screw-down pattern, with crutch or butterfly handle, screwed at both ends for connection to iron pipes or unions, including fixing and connections, complete, all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender