Tender For Improvement/Renovation Of Ringu Damsha Afat At Nalbari, Udalguri.
Tender Value
4.84 Crore
Estimated cost
Bid Submission
27 Nov 2026
8 days left
EMD
9.70 Lakhs
Bank guarantee accepted
Document Fee
9700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
udalguri → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement/Renovation Of Ringu Damsha Afat At Nalbari, Udalguri.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORK2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 2 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 3 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 5 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22.6A Thermo-Mechanically Treated bars of grade Fe-500D or more.Kg :- Slab 8mm (150 mm thick) |
| 6 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 7 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 9 | 5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 10 | 5.9.7 Stairs, (excluding landings) except spiral-staircases |
| 11 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.2 Cement Mortar 1:6 (1 cement : 6 coarse sand). |
| 13 | 2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 14 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 15 | 4.10 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 16 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 18 | 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.26.86.6 Frame size 65 x 125 mm |
| 19 | 26.87 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)26.87.2 35 mm thick |
| 20 | 21.10 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 21 | 9.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer’s specification and direction of Engineerin- Charge. |
| 22 | 9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom doorshutter). |
| 23 | 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 24 | 11.3 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 25 | 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.3 Size of Tile 800 x 800 mm |
| 26 | 11.23 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :11.23.6 Pink plain marble |
| 27 | 9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.9.3.2 Kiln seasoned and chemically treated hollock wood |
| 28 | 12.26 Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).12.26.1 6 mm thick Cement fiber board as per IS: 14862 |
| 29 | 13.5 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.1 1:4 (1 cement: 4 coarse sand) |
| 30 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | 13.45 Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm |
| 32 | 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 33 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22.6A Thermo-Mechanically Treated bars of grade Fe-500D or more.Kg :- Column (0.35x0.30) |
| 34 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 35 | SANITARY WORK17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :17.3.1 W.C. pan with ISI marked white solid plastic seat and lid each |
| 36 | 17.18.1 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete. 10 litre capacity - white. |
| 37 | 17.20.1 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete. White solid plastic seat with lid. |
| 38 | 17.22 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 39 | 17.16A Providing and fixing 8 mm dia C.P. / S.S. jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge. |
| 40 | 17.7.3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous china wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. |
| 41 | 17.10.1.1 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board 510x1040 mm, bowl depth 250 mm. |
| 42 | 17.31 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 43 | 17.73.1 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 44 | 18.65 Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 45 | 17.34.2 Providing and fixing toilet paper holder - vitreous china. |
| 46 | 17.22A Providing and fixing CP Brass 32 mm size bottle trap of approved quality and make as per the direction of Engineer-in-charge. |
| 47 | 17.60.2.2 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 75 mm outlet, sand cast iron S&S as per IS:1729. |
| 48 | 17.35.1.1 Providing and fixing soil, waste and vent pipes. 100 mm dia sand cast iron S&S pipe as per IS:1729. |
| 49 | 17.35.2.1 Providing and fixing soil, waste and vent pipes. 75 mm dia sand cast iron S&S pipe as per IS:1729. |
| 50 | 17.39.1.1 Providing and fixing plain bend of required degree. 100 mm dia sand cast iron S&S as per IS:1729. |
| 51 | 17.44.1.1 Providing and fixing single equal plain junction of required degree. 100x100x100 mm sand cast iron S&S as per IS:1729. |
| 52 | 17.39.2.1 Providing and fixing plain bend of required degree. 75 mm dia sand cast iron S&S as per IS:1729. |
| 53 | 17.56.1.1 Providing and fixing terminal guard. 100 mm sand cast iron S&S as per IS:1729. |
| 54 | 17.36.2 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I./C.I. pipes. 100 mm dia pipe. |
| 55 | 17.36.1 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I./C.I. pipes. 75 mm dia pipe. |
| 56 | 17.59.1 Providing and fixing M.S. stays and clamps for sand cast iron / centrifugally cast (spun) iron pipes of diameter 100 mm. |
| 57 | 17.59.2 Providing and fixing M.S. stays and clamps for sand cast iron / centrifugally cast (spun) iron pipes of diameter 75 mm. |
| 58 | 17.65.1 Painting sand cast iron / centrifugally cast (spun) iron soil, waste, vent pipes and fittings with two coats of synthetic enamel paint over a coat of primer (of approved quality) for new work. 100 mm diameter pipe. |
| 59 | 17.65.2 Painting sand cast iron / centrifugally cast (spun) iron soil, waste, vent pipes and fittings with two coats of synthetic enamel paint over a coat of primer (of approved quality) for new work. 75 mm diameter pipe. |
| 60 | 18.56.1 Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107 mm long, weighing not less than 110 gms. |
| 61 | 18.49.1 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15 mm nominal bore. |
| 62 | 18.16.1 Providing and fixing brass stop cock of approved quality. 15 mm nominal bore. |
| 63 | 18.8.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing, jointing with one step CPVC solvent cement, cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia pipes. |
| 64 | 18.8.3 CPVC pipes, concealed work, as per item above. 25 mm nominal dia pipes. |
| 65 | 18.8.2 CPVC pipes, concealed work, as per item above. 20 mm nominal dia pipes. |
| 66 | 18.8.1 CPVC pipes, concealed work, as per item above. 15 mm nominal dia pipes. |
| 67 | 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 25 mm nominal bore. |
| 68 | 18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 32 mm nominal bore. |
| 69 | 17.22B Providing and fixing CP Brass single lever telephonic wall mixer of quality and make as approved by Engineer-in-charge. 15 mm nominal dia. |
| 70 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 71 | 18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete. 25 mm nominal bore (one per tank). |
| 72 | SEPTIC TANK (2 Nos.)2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m2.8.1 All kinds of soil. |
| 73 | 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 74 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 75 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 76 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 77 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.3 Suspended floors, roofs, landings, balconies and access platform sqm |
| 78 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for5.9.13 Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 79 | 6.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum |
| 80 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 81 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 82 | 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.1 1:4 (1 cement: 4 fine sand) |
| 83 | 11.6 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.11.6.1 18 mm thick |
| 84 | FIRE SAFETYSupplying and placing Eco Extinguisher 4 kg Premium ABC dry powder type fire extinguisher, red (stored pressure, IS:15683), complete with wall mounting bracket. |
| 85 | Supplying and placing Agni-X 4.5 kg fire extinguisher, carbon dioxide gas, 131.56 bar testing pressure and 18 sec. discharge time, model PSS-CO2FE-4.5, complete with wall mounting bracket. |
| 86 | ELECTRIFICATION WORK1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.1.10.1 Group A |
| 87 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required1.14.1 a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 88 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required1.14.4 b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 89 | 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required1.14.11 c) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 90 | 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Extra / spare conduit only – item 1.14 already includes conduit; taken as 10% of 1.5 sq.mm circuit length)1.21.1 20 mm |
| 91 | 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Extra / spare conduit only – item 1.14 already includes conduit; taken as 10% of 1.5 sq.mm circuit length)1.21.3 32 mm |
| 92 | 1.27 Supplying and fixing following size/modules, GI Box along with modular base and cover plate for modular switches in recess etc as required.1.27.3 4 Module (125mmX75mm) |
| 93 | 1.27 Supplying and fixing following size/modules, GI Box along with modular base and cover plate for modular switches in recess etc as required.1.27.4 6 Module (200mmX75mm) |
| 94 | 1.27 Supplying and fixing following size/modules, GI Box along with modular base and cover plate for modular switches in recess etc as required.1.27.6 12 Module (200mmX150mm) |
| 95 | 1.24 Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.1.24.1 5/6 A switch |
| 96 | 1.24 Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.1.24.3 15/16 A switch |
| 97 | 1.24 Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.1.24.4 3 pin 5/6 A socket outlet |
| 98 | 1.24 Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.1.24.5 6 pin 15/16 A socket outlet |
| 99 | 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 100 | 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 101 | Bajaj Energon BLDC Ceiling Fan, 1200 mm, 350 RPM |
| 102 | 1.35 Installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 103 | 36W Cool White Bajaj LED Panel Square Light, Base Type: 2ft x 2ft |
| 104 | 12W Bajaj Ceiling Panel Light |
| 105 | 150W Bajaj LED Flood Light |
| 106 | 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required – up to 450 mm sweep. |
| 107 | Bajaj Maxima DX-G 02 150 mm Exhaust Fan |
| 108 | Voltas 2 Ton 3 Star Inverter Split AC, Venus Plus |
| 109 | Voltas 1.5 Ton 3 Star Inverter Split AC (indoor + outdoor unit) |
| 110 | AC installation kit per unit (copper piping set, drain pipe, cable, outdoor bracket, labour) |
| 111 | 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2.3.3 12 way, Double door |
| 112 | 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.10.1 a) Single pole |
| 113 | 2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.12.1 40 A |
| 114 | 2.14 Supplying and fixing following rating, double pole (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.14.2 40 A |
| 115 | Havells Velora Pro 15 L storage water heater (geyser) |
| 116 | Croma 90 L single-door mini refrigerator |
| 117 | 43-inch 4K Smart LED TV |
| 118 | TV wall-mount bracket with fixing |
| 119 | Electric kettle 1.5 L stainless steel |
| 120 | Wall-mounted hotel hair dryer 1600 W |
| 121 | 55-inch 4K Smart LED TV (lounge ×2, reception ×1) |
| 122 | Commercial vertical double-door refrigerator, 500 L |
| 123 | Deep freezer 300 L |
| 124 | Microwave oven 30 L convection |
| 125 | Commercial induction cooktop 3.5 kW |
| 126 | Kitchen hood / chimney 90 cm, SS commercial type |
| 127 | Mixer grinder 750 W |
| 128 | Commercial RO + UV water purifier 25 LPH |
| 129 | Hot & cold water dispenser |
| 130 | Front-load washing machine 8 kg |
| 131 | Tumble dryer 7 kg |
| 132 | Steam iron 2000 W |
| 133 | JBL EON712 12-inch 1300 W powered PA speaker |
| 134 | Speaker wall-mount bracket / stand, power & signal cable |
| 135 | Shure SVX24/PG58 wireless handheld microphone system |
| 136 | Shure SM58 wired dynamic microphone |
| 137 | 12-channel analog/USB mixer (Yamaha MG12XU) |
| 138 | Mic stands, XLR / speaker cables, connectors and rack (lump sum) |
| 139 | Projector 5000 lumen WUXGA with ceiling mount |
| 140 | Motorised projection screen 120-inch |
| 141 | Supply of 3.5C x 95 sq.mm Al. XLPE armoured 1.1 kV cable (pole → main panel, DG/AMF → main panel, main panel → floor distribution) |
| 142 | Supply of 3.5C x 35 sq.mm Al. XLPE armoured 1.1 kV cable (feeders to meeting hall, kitchen/laundry, staff and common DBs) |
| 143 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.2 Above 35 sq. mm and upto 95 sq. mm |
| 144 | 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.1 Upto 35 sq. mm |
| 145 | 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.7.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 146 | 7.7 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.7.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 147 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.24 3½ X 95 sq. mm (45mm) |
| 148 | 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.21 3½ X 35 sq. mm (32mm) |
| 149 | 14.16.2 Supplying and laying of DWC HDPE pipe ISI marked, 90 mm dia (OD-90 mm & ID-76 mm nominal) along with accessories conforming to IS 14930 Part II, direct in ground (75 cm below GL) including excavation and refilling, for protection of underground cable. |
| 150 | 14.13 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep )and re-filling etc as required14.13.2 a) 80 mm dia |
| 151 | 12.38 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 152 | 6.2 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, havingsingle prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 153 | 6.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required. (For horizontal run) |
| 154 | 6.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 155 | 6.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required |
| 156 | 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 157 | 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 158 | 5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 159 | 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 160 | 6.14 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required |
| 161 | BOUNDARY WALLProviding Brick Boundary wall with 1.8 m height above G.L. with 112mm thick brick wall with 250mmx250mm R.C.C. post with cement plastering on both sides and tie beam of 250mm x 250mm size including white washing on both sides of the wall surfaces etc etc………………. complete as directed by the Department. |
| 162 | OVER HEAD TANK2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. cum |
| 163 | 16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 164 | 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 165 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 166 | 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 167 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for -5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 168 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for -5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 169 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for -5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 170 | 5.9 Centering and shuttering including strutting, propping etc. and removal of form for -5.9.3 Suspended floors, roofs, landings, balconies and access platform |
| 171 | 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 172 | 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 173 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 174 | 13.5 15 mm cement plaster on rough side of single or half brick wall of mix : 13.5.2 1:6 (1 cement: 6 coarse sand) |
| 175 | 13.7 12 mm cement plaster finished with a floating coat of neat cement of mix :13.7.1 1:3 (1 cement: 3 fine sand) |
| 176 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 177 | 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 178 | 13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 179 | DEEP TUBE WELL8.1.1 Preparation of site for placement of the drilling rig including excavation of mud pit, circulation drain, collection chamber etc. all complete as directed. |
| 180 | 8.1.3 Transportation of all ancillary equipments, camp materials, welding set, rig accessories etc. including cost of P.O.L. all complete as directed.(a) for less than 100.00 m |
| 181 | 8.1.4 Transportation of all store materials like pipes, strainer, cone, socket, clamp, bentonite etc. including cost of P.O.L. all complete as directed.(a) for less than 100.00 m(b) Beyond 100.00 m |
| 182 | 8.1.5 Transportation of air compressor with all accessories including cost of P.O.L. allcomplete as directed. (a) for less than 100.00 m(b) Beyond 100.00 m |
| 183 | 8.1.6 Transportation of P.O.L. all complete as directed. |
| 184 | 8.1.7 Construction of temporary accommodation and low cost sanitary facility for drilling staff including cost of camp materials viz. cots, tables, chairs, utensils, dresses, safety helmets etc. and dismantling the accommodation after completion of the work all complete as directed. |
| 185 | 8.1.8 Providing water supply facilities at drilling site all complete as directed.(a) By installing 1 Nos. of Singur hand pump |
| 186 | 8.3.1 a) Drilling with drill bit in overburden portion of soil formation including collection of soil sample at every 3.0 m depth wherever there is a change of strata in sample boxes with distinguishing marks upto the depth of rock formation and withdrawing the drill bit for lowering casing as directed with 245mm to 300 mmm dia drill bit |
| 187 | 8.3.2 b) Casing / sinking / lowering of 200 mm dia MS pipe including cost of pipe and labour charge for casing, welding of joint by welding machine and sinking by drilling rig in portion all complete as directed by department. |
| 188 | 8.3.3 c ) 'Drilling with drilling rig using D.T.H. in all kinds of rock formation including collection of sample at every 3.0 m depth of boring or wherever there is a change of strata in sample boxes with distinguishing marks upto a required depth of boring along with breaking rock fracture for desired discharge, withdrawing drilling rod and finishing the borehole by ramming upto a required dia minimum 150mm dia upto the bottom and washing the well as per direction of the department all complete including testing of yield and drawdown of SWL of the DTW ..... |
| 189 | FILLING OF EARTH2.38 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. |
| 190 | LANDSCAPING8.76 Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. |
| 191 | 7.9 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 192 | 4.52 Providing and Displaying Petunia hybrid well developed with fresh & healthy foliage in full bloom 6-8 in 35 cm Earthen Tray/Nand as per direction of the officer-in-charge. |
| 193 | 5.12 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 194 | 4.4 Providing and Displaying Antirrhinum Hybrid dwarf variety, specimen (8-10) with fresh & healthy foliage in full bloom well developed in 35 cm Earthen Tray/Challi Pot and as per direction of the officer-in-charge. |
| 195 | 8.23 Providing and stacking of Ficus blackii (F.vivion) (bushy) of height 150-165 cm. with 8-10 branches and healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge. |
| 196 | APPROACH ROADAnalysis of cement concrete interlocking paver block Approach Road of width 3.75 m Carriage Way on 15 cm thick GSB , 75 mm WMM and 150 mm PCC Protection on Both Sides. |
| 197 | FURNITURE & FIXTURESSupplying with including fitting and fixing of Fiona Modular King Bed, Product ID: 56101515SD00018 (Size::191 x 95.6 x 206) along with Insignia SP 78 x 72 x 4 Mattress Product ID: 56101508SD07541 of Godrej Interio brand etc. complete as directed by the department. |
| 198 | Supplying with including fitting and fixing of Slimline 3 Door with Locker Metal (CRCA Steel) Almirah of Godrej Interio brand or equivalent etc. complete as directed by the department. |
| 199 | Supplying with including fitting and fixing of Rhythm Advance 3 Seater Sofa Product ID: 56101502SD01929 (Size::198 x 83.5 x 83) of Godrej Interio brand etc. complete as directed by the department. |
| 200 | Supplying with including fitting and fixing of Rhythm Advance 1 seater Sofa (Size::86 x 83.5 x 83), Product ID: 56101502SD01928 of Godrej Interio brand etc. complete as directed by the department. |
| 201 | Supplying with including fitting and fixing of Osaka Small Engineered Wood Centre/Coffee Table of Interio by Godrej brand or equivalent etc. complete as directed by the department. |
| 202 | Supplying with including fitting and fixing of Franky and Kalyx 4 Seater Wooden Square Dining Set (White) (Size:: 92 x 92 x 75) Product ID: FRAN4SSWHKAL of Godrej Interio brand or equivalent etc. as directed by the department. |
| 203 | Supplying with including fitting and fixing of Franky and Kalyx 8 Seater Wooden Rectangular Dining Set (Table with 8 Chairs) of Godrej Interio brand or equivalent etc. as directed by the department. |
| 204 | Supplying with including fitting and fixing of Godrej Ideate 6 Seater Conference/Meeting Table with wire manager and pop-up electric box (Size:: 2100 x 1200 x 745) of Godrej Interio brand or equivalent etc. as directed by the department. |
| 205 | Supplying with including fitting and fixing of Versa Neo Mid Back Revolving (Knee Tilt Synchro) Chair with adjustable arms of Godrej Interio brand or equivalent etc. as directed by the department. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender