Tender For Construction Of Two Section School Building And Development Of Other Facilities As Per Kvs Norms For Kvs At Krishnagiri Tamilnadu Under Kendriya Vidyalaya Sangathan, New Delhi. Sub-Head: Civil Works Including Electrical & Lv Work, Fire Fig
Tender Overview
Project Description
Tender for Construction Of Two Section School Building And Development Of Other Facilities As Per Kvs Norms For Kvs At Krishnagiri Tamilnadu Under Kendriya Vidyalaya Sangathan, New Delhi. Sub-Head: Civil Works Including Electrical & Lv Work, Fire Fighting, Fire Alarm Sanitary & Plumbing, Water Supply System, Lift, Solar Photovoltaic Power Generation System And All Allied Works Etc.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Nov-2026 | CORRIGENDUM-1 | Technical Bid | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | CONSTRUCTION WORK AT KRISHNAGIRI TAMILNADU UNDER KVS, NEW DELHI |
| 2 | CONSTRUCTION OF TWO SECTION SCHOOL BUILDING AND DEVELOPMENT OF OTHER FACILITIES AS PER KVS NORMS FOR KVS AT KRISHNAGIRI TAMILNADU UNDER KENDRIYA VIDYALAYA SANGATHAN, NEW DELHI.” |
| 3 | \\"NOTE:-THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, FEE, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST.\\" Please Enable Macros to View BoQ information Tender Inviting Authority: BRIDGE AND ROOF CO. (INDIA) LIMITED., KANKARIA CENTRE, 4TH & 5TH FLOOR, 2/1, RUSSEL STREET, KOLKATA - 700071 Name of Work: CONSTRUCTION OF TWO SECTION SCHOOL BUILDING AND DEVELOPMENT OF OTHER FACILITIES AS PER KVS NORMS FOR KVS AT KRISHNAGIRI TAMILNADU UNDER KENDRIYA VIDYALAYA SANGATHAN, NEW DELHI.” SUB-HEAD: Civil Works including Electrical & LV work, Fire Fighting, Fire Alarm Sanitary & Plumbing, Water Supply system, Lift, Solar Photovoltaic Power Generation system and all allied works etc. Notice Inviting e-Tender (eNIT) No : B AND R / HO / 51300 / KVS / KRISHNAGIRI / NIT / CW / 01, DATED 07.11.2026 Name of the Bidder/ Bidding Firm / Company : SNo. DESCRIPTION CPWD DSR Ref.: 2023 QUANTITY UNIT RATE Rate 99.027% Cost Index 16% RATE EXCLUDING GST 18% AMOUNT A CIVIL WORKS Carriage Of Materials A |
| 4 | By Mechanical Transport including loading,unloading and stacking Earth Lead 1 km 1.1.2 1274.01 Cum 217.55 215.43 249.9 211.78 269809.84 211.78 EARTHWORK A 0.0 |
| 5 | Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift : All kinds of soil 2.2.1 5225.0 Cum 395.3 391.45 454.08 384.82 2010684.5 384.82 |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.: 2.6.1 6061.82 Cum 177.5 175.77 203.89 172.79 1047421.88 172.79 |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed ,within a lead of 50m. All kinds of soil 2.8.1 2536.58 Cum 260.3 257.77 299.01 253.4 642769.37 253.4 |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 9 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 10 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. : For Excavation beyond 1.5m depth All kinds of soil 2.26.1 1890.83 Cum 126.8 125.57 145.66 123.44 233404.06 123.44 |
| 11 | Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. |
| 12 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish , lead upto 50 meter and lift upto 1.5 meter |
| 13 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 14 | Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 2.34.1 919.42 Liter 234.75 232.47 269.67 228.53 210115.05 228.53 |
| 15 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) i Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 0.0 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 2.35.2.1 1058.54 Meter 53.45 52.93 61.4 52.03 55075.84 52.03 ii Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 0.0 With Chlorpyriphos/Lindane E.C. 20% with 1% concentratio 2.35.3.1 3017.44 Sqm 310.05 307.03 356.15 301.83 910753.92 301.83 |
| 16 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
| 17 | Supplying, Providing & fixing of Brick Bats with direction of Engineer-in-charge. CONCRETE WORK B 0.0 |
| 18 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level: i 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 4.1.3 136.294 cum 7878.5 7801.84 9050.13 7669.61 1045321.83 7669.61 ii 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) 4.1.8 155.434 cum 6812.0 6745.72 7825.04 6631.39 1030743.47 6631.39 |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form work for : i Foundations, footings, bases for columns 4.3.1 808.97 sqm 392.15 388.33 450.46 381.75 308824.3 381.75 |
| 20 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. REINFORCED CEMENT CONCRETE C 0.0 |
| 22 | Centering & shuttering including strutting, propping etc. and removal of form work for: i Foundations, footings, bases of columns etc. for mass concrete. 5.9.1 985.66 sqm 392.15 388.33 450.46 381.75 376275.71 381.75 ii Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 5.9.2 1468.68 Sqm 842.5 834.3 967.79 820.16 1204552.59 820.16 iii Suspended floors, roofs, landings, balconies and access platform. 5.9.3 8360.77 sqm 927.25 918.23 1065.15 902.66 7546932.65 902.66 iv Lintels, beams, plinth beams, girders, bressumers and cantilevers. 5.9.5 8015.69 sqm 736.4 729.23 845.91 716.87 5746207.69 716.87 v Columns, Pillars, Piers, Abutments, Posts and Struts 5.9.6 5811.21 sqm 961.3 951.95 1104.26 935.81 5438188.43 935.81 vi Stairs, (excluding landings) except spiral-staircases 5.9.7 809.02 sqm 764.95 757.51 878.71 744.67 602452.92 744.67 vii Chimneys and shafts 5.9.11 100.0 Sqm 803.25 795.43 922.7 781.95 78195.0 781.95 viii Extra for shuttering in circular work (20% of respective centering and shuttering items) 5.9.14 0.0 Column a 100.0 Sqm 192.26 190.39 220.85 187.16 18716.0 187.16 ix Edges of slabs and breaks in floors and walls 5.9.16 0.0 Under 20 cm wide 5.9.16.1 611.35 Sqm 208.55 206.52 239.56 203.02 124116.28 203.02 x Weather shade, Chajjas, corbels etc., including edges 5.9.19 100.0 Sqm 951.1 941.85 1092.55 925.88 92588.0 925.88 |
| 23 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 5.11.1 825.63 Sqm 384.3 380.56 441.45 374.11 308876.44 374.11 |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 5.22.6 154666.57 kg 107.85 106.8 123.89 104.99 16238443.18 104.99 |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more 5.22A.6 463440.49 kg 107.85 106.8 123.89 104.99 48656617.05 104.99 |
| 26 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections |
| 27 | Supplying, Providing & fixing of chicken mesh wire with direction of Engineer-in-charge. |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note :- Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.. 0.0 a All works upto plinth level 5.33.1 0.0 i Concrete of M25 grade with minimum cement content of 330 kg /cum 5.33.1.1 1002.75 cum 9504.75 9412.27 10918.23 9252.74 9278185.04 9252.74 ii Concrete of M30 grade with minimum cement content of 350 kg /cum 5.33.1.2 186.99 cum 9655.7 9561.75 11091.63 9399.69 1757648.03 9399.69 b All works above plinth level upto floor V level 5.33.2 0.0 i Concrete of M25 grade with minimum cement content of 330 kg /cum 5.33.2.1 2806.87 Cum 9860.4 9764.46 11326.77 9598.96 26943032.86 9598.96 ii Concrete of M30 grade with minimum cement content of 350 kg /cum 5.33.2.2 655.09 Cum 10011.35 9913.94 11500.17 9745.91 6384448.18 9745.91 |
| 29 | Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. BRICK WORK D 0.0 |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 6.1.2 129.23 Cum 7132.25 7062.85 8192.91 6943.14 897261.98 6943.14 |
| 31 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 6.4.1 50.93 cum 9344.35 9253.43 10733.98 9096.59 463289.33 9096.59 |
| 33 | Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means HALF BRICK MASONRY 0.0 |
| 34 | Half brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth and upto floor V level Cement mortar 1 : 4 (1 cement : 4 coarse sand) 6.45.2 972.1 Sqm 1105.8 1095.04 1270.25 1076.48 1046446.21 1076.48 |
| 35 | Extra for half brick masonry in superstructure, above floor V level for every four floors or part there of by mechanical means. |
| 36 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. DOORS & WINDOWS WORKS E 0.0 |
| 37 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 9.7.7 0.0 4 mm thick glass pane (weight not less than 10kg/sqm). 9.7.7 65.34 Sqm 2241.8 2219.99 2575.19 2182.36 142595.4 2182.36 |
| 38 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 9.21.1 394.59 Sqm 2392.65 2369.37 2748.47 2329.21 919082.97 2329.21 |
| 39 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 40 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square 9.24.1 13.91 sqm 199.15 197.21 228.76 193.87 2696.73 193.87 |
| 41 | Providing and fixing bright finished brass door latch with necessary screws etc. complete 300x16x5 mm 9.75.1 R.O Each 322.2 319.06 370.11 313.66 313.66 |
| 42 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) 0.0 |
| 43 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete i 300x16 mm 9.96.1 27.0 Each 303.25 300.3 348.35 295.21 7970.67 295.21 ii 250x16 mm 9.96.2 332.0 Each 260.6 258.06 299.35 253.69 84225.08 253.69 |
| 44 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : i 300 x 10 mm 9.97.1 47.0 Each 130.1 128.83 149.44 126.65 5952.55 126.65 ii 200x10 mm 9.97.3 345.0 Each 99.7 98.73 114.53 97.06 33485.7 97.06 |
| 45 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : i 125 mm 9.100.1 417.0 Each 66.25 65.61 76.11 64.49 26892.33 64.49 ii 100 mm 9.100.2 182.6 Each 59.55 58.97 68.41 57.97 10585.32 57.97 |
| 46 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. i Single rubber stopper 9.101.1 292.6 Each 39.6 39.21 45.48 38.55 11279.73 38.55 |
| 47 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. i 1.0 mm thick 9.127.2 2430.12 Sqm 897.3 888.57 1030.74 873.51 2122734.12 873.51 |
| 48 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. i Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi point locking system. (Height above 1.8m) 9.147.A4.3 597.78 Sqm 12372.25 12251.87 14212.17 12044.21 7199787.85 12044.21 |
| 49 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. i Frame size 50 x 125 mm 26.86.4 410.85 Meter 1075.7 1065.23 1235.67 1047.18 430233.9 1047.18 |
| 50 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) i 35 mm thick 26.87.2 130.725 Sqm 5015.35 4966.55 5761.2 4882.37 638247.82 4882.37 STEEL WORK F 0.0 |
| 51 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 52 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 53 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer i Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 10.15.1 2357.76 Kg 195.2 193.3 224.23 190.02 448021.56 190.02 |
| 54 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. i In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete 10.25.1 R.O Kg 123.6 122.4 141.98 120.32 120.32 ii In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 10.25.2 6347.28 Kg 172.6 170.92 198.27 168.02 1066469.99 168.02 |
| 55 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. i Fixed to steel windows by weldings 9.48.1 17109.68 KG 219.1 216.97 251.69 213.29 3649323.65 213.29 |
| 56 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 57 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost ofproviding and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. i 80x1.25 mm M.S. laths with 1.25 mm thick top cover 10.6.1 9.0 Sqm. 3653.2 3617.65 4196.47 3556.34 32007.06 3556.34 |
| 58 | Providing and fixing ball bearing for rolling shutters |
| 59 | Extra for providing mechanical device chain and crank operation for operating rolling shutters. i Exceeding 10.00 sqm and upto 16.80 sqm in the area 10.8.1 9.0 Sqm. 1281.35 1268.88 1471.9 1247.38 11226.42 1247.38 |
| 60 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead oflaths as per design approved by Engineer-in- charge, (area of grill to be measured). FLOORING WORK G 0.0 |
| 61 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : i 25 mm thick 11.26.1 6007.23 Sqm 1948.25 1929.29 2237.98 1896.59 11393252.35 1896.59 |
| 62 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 63 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. i Double charge vitrified tile polished finish of size 11.41 A.1 0.0 Size of Tile 600 x 1200 mm 11.41A.1.3 1164.94 Sqm 1577.15 1561.8 1811.69 1535.33 1788567.33 1535.33 ii Glazed Vitrified tiles Matt/Antiskid finish of size 11.41.A.3 0.0 Size of Tile 600 x 600 mm 11.41A.3.1 587.53 Sqm 1464.85 1450.6 1682.7 1426.01 837823.66 1426.01 |
| 64 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in Charge: |
| 65 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : i Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 11.55.1 R.O Sqm 3186.7 3155.69 3660.6 3102.21 3102.21 |
| 66 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone lab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. i Polished Granite stone slab jet Black, Cherry/Ruby, Red or equivalent. 11.56.1 214.485 Sqm 4481.3 4437.7 5147.73 4362.48 935686.52 4362.48 CLADDING WORK E 0.0 |
| 67 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. i Granite stone slab colour black, Cherry/Ruby red 8.2.2 0.0 Area of slab over 0.50 sqm 8.2.2.2 415.81 Sqm 5136.3 5086.32 5900.13 5000.11 2079095.74 5000.11 |
| 68 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge i Granite work 8.3.2 417.7 Meter 510.95 505.98 586.94 497.4 207763.98 497.4 |
| 69 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 70 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 71 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Note : For Internal & External wall Size & Colour as per the drawing. Roofing Work H 0.0 |
| 72 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever i 0.63 mm thick with zinc coating not less than 275 gm/ m² 12.1.3 1200.0 Sqm 1087.65 1077.07 1249.4 1058.81 1270572.0 1058.81 |
| 73 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design i In 75x75 mm deep chase 12.21.1 500.0 Mtr 305.15 302.18 350.53 297.06 148530.0 297.06 |
| 74 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and makingand finishing the outlet complete. |
| 75 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner |
| 76 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process 12.59.1 R.O Sqm 1572.3 1557.0 1806.12 1530.61 1530.61 Finishing Work J 0.0 CEMENT PLASTER ( IN FINE SAND) 0.0 |
| 77 | 12 mm cement plaster of mix : i 1:4 (1 cement: 4 fine sand) 13.1.1 20264.89 sqm 347.05 343.67 398.66 337.85 6846493.09 337.85 |
| 78 | 6 mm cement plaster of mix : i 1:3 (1 cement : 3 fine sand) 13.16.1 8840.42 sqm 300.45 297.53 345.13 292.48 2585646.04 292.48 CEMENT PLASTER ( IN COARSE SAND) 0.0 |
| 79 | 15 mm cement plaster of mix : i 1:6 (1 cement: 6 coarse sand) 13.5.2 1558.66 sqm 395.35 391.5 454.14 384.87 599881.47 384.87 |
| 80 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : i 1:3 (1 cement : 3 fine sand) 13.8.1 351.12 Sqm 494.3 489.49 567.81 481.19 168955.43 481.19 |
| 81 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 82 | Neat cement punning |
| 83 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 84 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 85 | For Exterior wall - Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. i New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 13.48A.1 11461.11 sqm 181.25 179.49 208.21 176.44 2022198.25 176.44 Applying priming coat: 13.5 0.0 |
| 86 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 87 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre |
| 88 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 89 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : i Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 13.62.1 430.76 Sqm 226.25 224.05 259.9 220.25 94874.89 220.25 |
| 90 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 91 | For Interior - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. i Two or more coats on new work 13.83.2 25799.72 sqm 142.8 141.41 164.04 139.01 3586419.08 139.01 ROAD WORKS K 0.0 |
| 92 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 93 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) |
| 94 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. i Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. 16.46.1 1000.0 per cm depth per cm width per metre length 8.65 8.57 9.94 8.42 8420.0 8.42 |
| 95 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 96 | Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment) i Overhead informatory road signage 16.60.1 77.0 Sqm 5879.9 5822.69 6754.32 5724.0 440748.0 5724.0 |
| 97 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 98 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). |
| 99 | Construction of dry lean cement concrete sub base over a prepared sub grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. |
| 100 | Separation Membrane of impermeable plastic sheeting 125 micron thick |
| 101 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4(1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 102 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. i 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 16.91.1 949.98 Sqm 1045.65 1035.48 1201.16 1017.93 967013.14 1017.93 WATER PROOFING N 0.0 |
| 103 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 0.0 IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface 0.0 IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 0.0 IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 644.49 Sqm 769.6 762.11 884.05 749.19 482845.46 749.19 |
| 104 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : NEW TECHNOLOGIES AND MATERIALS 26.0 0.0 |
| 105 | Applying stamping finish to the top surface of freshly laid plain/reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the Engineer-in-Charge. The process shall include the following: • The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. The approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while concrete is in plastic stage of setting. • After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface. • The construction joints shall be provided by groove cutting of size 4 mm x 20 mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.) HORICULTURE Q 0.0 |
| 106 | Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). i In rows 5 cm apart in both directions 2.10.1 32166.54 Sqm 17.7 17.53 20.33 17.23 554229.48 17.23 |
| 107 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 108 | Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 109 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) i Shrubs Plant 2.57.2 1608.0 Each 3.65 3.61 4.19 3.55 5708.4 3.55 |
| 110 | Providing and displaying of Araucaria cookie having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge. |
| 111 | Providing and displaying of Areca Palm having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 112 | Providing and displaying of Brassia Variegated having ht. 30 cm to 45 cm, well developed with fresh and healthy foliage in 25 cm size of Earthen pot /Plastic pot. & as per direction of the officer-in-charge. |
| 113 | Providing and displaying of Croton Petra having ht. 45 cm & above with 2 to 3 branches, well developed, fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge. |
| 114 | Providing and displaying of Monestaria mounted on moss stick 90 cm ht., 2 to 3 in one pot well developed with fresh & healthy foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge |
| 115 | Providing and displaying of Raphes palm having ht. 45 cm to 60 cm with 5 to 7 suckers, well developed, full of fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge |
| 116 | Supplying, Providing & fixing of Polycarbonate Sheet with direction of Engineer-in-charge. 2.8 mm Thick – Corrugated Polycarbonate • The distance between centre to centre between the crest shall be 76 mm.• The height of the crest shall not be less or more than 18 mm.• The overall width of the Sheets shall be 1045mm and the cover width shall not be less than 980 mm.• The panels shall be able to counter act the load of 150 kg/m2 with the mid field purlin spacing of 1250 mm and at the end field with a purlin spacing of 940 mm.• The density of the polycarbonate sheets shall not be less than 1.2 grams/cm3• Head deflection temperature shall be in the range of 120-130degree celcius• The thermal conductivity of the panels shall 0.21W/MK• Impact Strength of the panels shall be 75 Joules• The Manufacturer shall provide Warranty for the product for 10 years. 3238.56 Sqm 2041.09 1729.74 5601866.77 1729.74 |
| 117 | Supply, Installation, and Fixing of External Signages Using Stainless Steel Letters 304 Grade Stainless Steel with side raising 1\\" to be fixed at all heights. The cost includes the cost of strutting and propping required for fixing of signages as per direction of engineer-in-charge |
| 118 | Providing, fixing, supplying & commissioning of FIRE SHAFT DOOR - Shaft Door - Size -1200 x2800 mm Material -Stainless SteelDoor Type -Double Door with Vision panelFinish - Color CoatedSurface Finishing - Powder CoatedOpen Style - HingedThickness - 46mmAs per direction .architect & engineer-in-charge. |
| 119 | GYM Equipment WITH Installation i AIR WALKER 1.0 1.0 Each 12492.37 10586.75 10586.75 10586.75 ii SINGLE PULL CHAIR 2.0 1.0 Each 15260.92 12932.98 12932.98 12932.98 iii ARM WHEEL 3.0 1.0 Each 11108.09 9413.64 9413.64 9413.64 iv ELEPTICAL EXERCISER 4.0 1.0 Each 12769.22 10821.37 10821.37 10821.37 v SKY WALKER 5.0 1.0 Each 12907.65 10938.69 10938.69 10938.69 vi BADMINTON POLE FIX 7.0 1.0 Each 5294.13 4486.55 4486.55 4486.55 vii VOLLEY BALL FIX 8.0 1.0 Each 6678.41 5659.67 5659.67 5659.67 viii BASKETBALL POLE FIX PAIR 9.0 1.0 Each 69247.67 58684.47 58684.47 58684.47 ix MONKEY BAR 10.0 1.0 Each 16645.2 14106.1 14106.1 14106.1 x DUCK SPRING 11.0 1.0 Each 8339.54 7067.41 7067.41 7067.41 xi DOUBLE SWING 12.0 1.0 Each 13876.64 11759.86 11759.86 11759.86 |
| 120 | Synthetic Turf - Volleyball and Basketball court |
| 121 | Supply, Installation, and Fixing of Stainless Steel Sinage as per direction of engineer-in-charge SS 304 plate, 1.5 mm thick,Laser engraving / lettering,SS screws, spacers and accessories,Finishing and polishing 10.0 Sqm 8616.0 7301.69 73016.9 7301.69 ELECTRICAL (SCHOOL BUILDING) 0.0 POINT WIRING & ACCESSORIES WIRING IN PVC CONDUIT 0.0 |
| 122 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.10.3 539.0 Point 1704.0 1444.07 778353.73 1444.07 |
| 123 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.55.3 463.0 Point 994.0 842.37 390017.31 842.37 |
| 124 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 125 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 126 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 127 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 6 pin 5/6 &15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 128 | Supplying and fixing call bell /buzzer suitable for single phase,230V complete as required as required. |
| 129 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required.(For AC) |
| 130 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 131 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 132 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required. i 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1.14.2 4500.0 Meter 311.0 263.56 1186020.0 263.56 ii 2X 4 sq. mm + 1 X 4 sq. mm earth wire 1.14.3 1500.0 Meter 373.0 316.1 474150.0 316.1 iii 2X 6 sq. mm + 1 X 6 sq. mm earth wire 1.14.4 10.0 Meter 482.0 408.47 4084.7 408.47 iv 2X 10 sq. mm + 1 X 6 sq. mm earth wire 1.14.5 500.0 Meter 621.0 526.27 263135.0 526.27 v 4X 10 sq. mm + 2 X 6 sq. mm earth wire 1.14.10 R.O Meter 1078.0 913.56 913.56 vi 4X 16 sq. mm + 2 X 6 sq. mm earth wire 1.14.11 500.0 Meter 1454.0 1232.2 616100.0 1232.2 |
| 133 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed steel conduit as required. i 2X 4 sq. mm + 1 X 4 sq. mm earth wire 1.7.2 R.O Meter 414.0 350.85 350.85 ii 2X 10 sq. mm + 1 X 6 sq. mm earth wire 1.7.5 R.O Meter 778.0 659.32 659.32 iii 4X 10 sq. mm + 2 X 6 sq. mm earth wire 1.7.10 R.O Meter 1253.0 1061.86 1061.86 iv 4X 16 sq. mm + 2 X 6 sq. mm earth wire 1.7.11 R.O Meter 1760.0 1491.53 1491.53 |
| 134 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 3200.0 Meter 151.0 127.97 409504.0 127.97 ii 25 mm 1.21.2 2500.0 Meter 168.0 142.37 355925.0 142.37 iii 32 mm 1.21.3 1500.0 Meter 209.0 177.12 265680.0 177.12 iv 40 mm 1.21.4 R.O Meter 257.0 217.8 217.8 v 50 mm 1.21.5 R.O Meter 316.0 267.8 267.8 |
| 135 | Supplying and fixing following modular switch/socket with modular plate switch box including connections & modular plate etc. as required. i Telephone socket outlet 1.24.6 26.0 Each 168.0 142.37 3701.62 142.37 ii TV.Socket outlet 1.24.7 4.0 Each 168.0 142.37 569.48 142.37 |
| 136 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 137 | Providing and fixing circular /hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140mm 73mm height top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed in to the cast iron/MS sheet box by means of 3.3mm dia round headed screws,one lock at the corners.Clamp shall be made of 12mm dia MS bar bent to shape as per standard drawing. |
| 138 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 139 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. i 3 Module (100 mmX75 mm) 1.27.2 45.0 Each 384.0 325.42 14643.9 325.42 |
| 140 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. LIGHTING FIXTURES & FANS 0.0 |
| 141 | Supply Installation Testing and Commissioning of 1 x 36 to 40 watt surface / wall mounted 1200 mm long High Power LED batten made out extruded alumiinium with poly carbonate difusser .The LED lamps should have a system efficacy of 120 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <10% surge protection of 2.5 kv, 50000 hours LED life @ L70 and driver efficiency > 85%.Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registration complete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required. |
| 142 | Supply Installation Testing and Commissioning of 1 x 10 to 12 watt wall mounted mirror light of 600 mm long High Power LED batten made out extruded alumiinium with poly carbonate difusser. The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <20% surge protection of 2.5 kv, 35000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registrationcomplete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required. |
| 143 | Supplying, installation, testing & Commissioning of surface type 15W to 16W LED Round Downlight with pressure die-cast aluminium heat sink & glarefree opal Diffuser. The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <10% surge protection of 2.5 kv, 50000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registration complete with all accessories etc with 1.5 sq mm |
| 144 | Supplying, installation, testing & Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Energy efficient 5-star 1200 mm sweep. 286.0 Each 2688.0 2277.97 651499.42 2277.97 |
| 145 | Supplying, Installation, Testing & Commissioning Exhaust Fans of the following sizes & specifications suitable for single Phase 230 V supply including but not limited to providing & connecting with suitable & required length PVC insulated wiring & plugs to the exising socket & making openings / holes / required fixing arrangement & making good the damage complete as per manufactures specifications & direction of the Engineer - in - charge. |
| 146 | 450 mm sweep heavy duty, Exhaust Fans, 900 rpm, 75 m3 / minute air delivery with 4 blades dynamically balanced impellers, pre lubricated double ball bearing, 130-140 watt power consumption , 50 Hz, 223V-240V, 50 - 60 noise level & 2 hours fiire rating. |
| 147 | Supplying, of 10W LED Bulkhead Light fixture IP66 Complete with aluminium housing ,integrated driver &all accessories as required. |
| 148 | TELECOMMUNICATION SYSTEM |
| 149 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 350.0 Meter 151.0 127.97 44789.5 127.97 ii 25 mm 1.21.2 100.0 Meter 168.0 142.37 14237.0 142.37 iii 32 mm 1.21.3 R.O Meter 209.0 177.12 177.12 iv 40 mm 1.21.4 R.O Meter 257.0 217.8 217.8 v 50 mm 1.21.5 R.O Meter 316.0 267.8 267.8 |
| 150 | Supply, Installation & commissioning of 50 Pair MDF Box with Koron Module (Tagging Unit) Complete with MS Enclosure and complete as required. i 100 pair 1.0 Nos 3873.5 3282.63 3282.63 3282.63 |
| 151 | Supplying and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated ,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
| 152 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ PVC conduit as required. i 1 run of cable 1.53.1 800.0 Meter 67.0 56.78 45424.0 56.78 MCB DISTRIBTION BOARD 0.0 |
| 153 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) i 12 way, Double door 2.3.3 8.0 Each 2315.0 1961.86 15694.88 1961.86 |
| 154 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i 6 way (4 + 18), Double door 2.4.2 R.O Each 4974.0 4215.25 4215.25 ii 8 way (4 + 24), Double door 2.4.3 R.O Each 4974.0 4215.25 4215.25 |
| 155 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) i 4 way (4 + 12), Double door 2.5.1 R.O Each 7512.0 6366.1 6366.1 ii 8 way (4 + 24), Double door 2.5.2 2.0 Each 10165.0 8614.41 17228.82 8614.41 iii 12way (4 + 36), Double door 2.5.3 16.0 Each 12833.0 10875.42 174006.72 10875.42 |
| 156 | Supplying and fixing 5 A to 32 A rating, 240/415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i Single pole . 2.10.1 704.0 Each 256.0 216.95 152732.8 216.95 |
| 157 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 158 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 A 2.14.2 10.0 Each 2642.0 2238.98 22389.8 2238.98 |
| 159 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 A 2.15.2 8.0 Each 3188.0 2701.69 21613.52 2701.69 ii 63 A 2.15.3 8.0 Each 2872.0 2433.9 19471.2 2433.9 |
| 160 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 161 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 162 | Supplying and fixing Cable End Box (Loose wire box)suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCB DB 2.23.4 8.0 Each 902.0 764.41 6115.28 764.41 |
| 163 | Supplying and fixing Cable End Box (Loose wire box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 4 way, Double door TPN MCBDB 2.24.1 R.O Each 1080.0 915.25 915.25 |
| 164 | Supplying and fixing Cable End Box (Loose wire box)suitable for following triple pole and neutral, sheet steel,vertical MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required. CABLE TRAY/DWC HDPE PIPE 0.0 |
| 165 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. i 150 mm width X 50 mm depth X 1.6 mm thickness 4.1.2 10.0 Meter 604.0 511.86 5118.6 511.86 ii 300 mm width X 50 mm depth X 1.6 mm thickness 4.1.4 10.0 Meter 777.0 658.47 6584.7 658.47 iii 450 mm width X 50 mm depth X 1.6 mm thickness 4.1.6 R.O Meter 1137.0 963.56 963.56 iv 600 mm width X 50 mm depth X 1.6 mm thickness 4.1.7 R.O Meter 1366.0 1157.63 1157.63 HDPE PIPE 14.15 0.0 |
| 166 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. i 120 mm dia (OD-120 mm & ID-103 mm nominal) 15.15.3 50.0 Meter 264.0 223.73 11186.5 223.73 ii 200 mm dia (OD-200 mm & ID-175 mm nominal) 15.15.5 100.0 Meter 580.0 491.53 49153.0 491.53 LIGHTNING SYSTEM 0.0 |
| 167 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required. |
| 168 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required. |
| 169 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run) |
| 170 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For vertical run) |
| 171 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 172 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. DG SET 0.0 |
| 173 | Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (C) Alternator:Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK:Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. 217 0.0 Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fi tted complete with all the required accessories. (a) 0.0 (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total),KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMSintegration including suitable software, the panel shall be of DG Set OEM make etc. as per approved byEngineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, (b) 0.0 D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to performthe operation shall be provided by the contractor including all control wiring. 0.0 i 62.5 kVA 29.1.5 1.0 Sets 597453.0 506316.1 506316.1 506316.1 EXTERNAL ELECTRIFICATION 0.0 |
| 174 | Supply, Laying & Testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification in ground (including trenches) through pipe or on wall / racks cable trays including dressing and clamping the cable with MS zinc passivated clamps etc. as required. i 3.5C x 300 sq.mm 300.0 Metre 2407.2 2040.0 612000.0 2040.0 ii 3.5C x 150 sq.mm 0.0 iii 3.5C x 120 sq.mm 0.0 iv 3.5C x 50 sq.mm 0.0 v 4C x 25 sq.mm (For stp, ext ltg & plumbing ) 500.0 Metre 515.0 436.44 218220.0 436.44 vi 4C x 16 sq.mm(For water supply pump & fire terrace pump panel) 100.0 Metre 448.5 380.08 38008.0 380.08 |
| 175 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1KV grade as required. i 3.5C x 300 sq.mm 9.1.30 8.0 Each 1027.0 870.34 6962.72 870.34 ii 3.5C x 150 sq.mm 9.1.26 R.O Each 697.0 590.68 590.68 iii 3.5C x 120 sq.mm 9.1.25 R.O Each 613.0 519.49 519.49 iv 3.5C x 50 sq.mm 9.1.11 R.O Each 413.0 350.0 350.0 v 4C x 25 sq.mm (For lift) 9.1.34 12.0 Each 315.0 266.95 3203.4 266.95 vi 4C x 16 sq.mm(For water supply pump & fire terrace pump panel) 9.1.33 6.0 Each 309.0 261.86 1571.16 261.86 TWO POLE STRUCTURE MR 0.0 |
| 176 | Supply, erection and commissioning of 2 pole structure for terminating 11 KV over head/under ground supply from Electricity Boards as per specifications. The 2-pole structure shall comprise of: MS tubular swaged pole 11 mtrs high, in cement concrete foundation 1:3:6 (1 cement : 3 coarse sand : 6 graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint - 2 Nos. 0.0 Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for cross arms, bracings, supports etc. for pole GOD etc. including anticlimbing barbed wires (conforming to latest BS) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall be given 2 coats of red oxide primer and 2 finishing coats of aluminium paint as required as per drawings and direction of Engineer-in-Charge. - Lot 0.0 Supply,installation, testing and commissioning of 11 KV class disc/pin/support insulators complete with clamps and fixing hardwares etc. complete as required as per drawings and direction of Engineer-in-Charge-Lot 0.0 Supply,installation, testing and commissioning of 11 KV station class thyrite type lightning arrestors complete with mounting arrangement (on all phases) - 3 Nos. 0.0 Supply,installation, testing and commissioning of drop out - lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement-1 Set 0.0 Supply,installation, testing and commissioning of GI stay set complete with 20mm dia 1.8 Metre long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles, stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling - 2 Set 0.0 Note: The excavation and other civil works related to two pole structure are to be included in cost. 0.0 Two pole structure as described above. 1.0 Set 281710.2 238737.46 238737.46 238737.46 HT CABLING &TERMINATION 0.0 |
| 177 | SINGLE PANEL 11KV VCB PANEL Incomer / outgoing. 0.0 1 No. 11kV 400A 18.4kA, 350 MVA, drawout type VCB with motorised spring charge mechanism for 240V AC, closing & tripping coils suitable for 24V DC. 0.0 1 No. Mechanical ON/OFF Indicator. 0.0 1 No. Aux Switch 6NO + 6NC. 0.0 1No.Power pack 0.0 Panel, Busbar, CT, PT 0.0 1 No. Fully compartmentalised sheet steel enclosure floor mounting type with automatic safety shutters, independent pressure discharge flaps, 400A, PVC sleeved, Copper busbar, etc with provision for terminating PVC/PILC/XLPE Cable. 0.0 3 Nos. Resin Cast CTs 20/1A withCore 1 : 7.5VA CL 1Core 2 : 7.5VA CL 5P10 0.0 3 Nos. PT - 11 KV/√3//110/√3V ,CL 1.0, 50VA 0.0 Breaker Panel indication Lamps : 0.0 6 Nos. ON/OFF/TRIP/TRIP Ckt Healthy/Spring Charged 0.0 Switches and other Accessories 0.0 5 nos.Fuses 0.0 1 No. Heater 0.0 1 No. Thermostat 0.0 1 No. 6 Window Annunciator 0.0 1 No. Plug & Socket 0.0 1 No. Test Terminal Block 0.0 1 No. T-N-C Switch 0.0 1 No. Emergency Push Button 0.0 1 No. Local/Remote Selector Switch 0.0 Meters 0.0 1 No. Analog Ammeter + ASS 0.0 1 No. Analog Voltmeter + VSS 0.0 1 No. Digital Multifunction Meter 0.0 Relays 0.0 1 No. (O/C+S/C + E/F - IDMT+Inst) Relay. 0.0 1 No. AVAJH13 Master trip relay 0.0 1 No. TCS Relay 0.0 Note:- 0.0 All Meters shall be Digital type 0.0 Potential free contact to be provided for HT Panel in each breaker to be used for annunciation in the control room. 0.0 The potential free contacts for transformer troubles annunciation & trips for WTI should be provided for remote annunciation in the control room. Required contactors / control relays with sufficient NO/NC contacts shall be provided. 0.0 Interchange billing features test and service position (electro / mechanical). 0.0 HT Panel described as above MR 1.0 Nos. 74653.2 63265.42 63265.42 63265.42 HT CABLING AND END TERMINATION MR 0.0 11 KV GRADE H.T. CABLES: 0.0 |
| 178 | Supplying of following sizes of XLPE aluminium conductor, corss linked polythylene, individual core screwed, flat steel strip armoured, PVC sheathed cable of 11KV grade (earthed) comforming to IEEE,with uptodate ammendment complete as required. 3 C x 120 Sq.mm XLPE HT cable (Earthed) MR 100.0 Metre 2828.2 2396.78 239678.0 2396.78 |
| 179 | Laying of one number PVC inulated and PVC sheathed/XLPE power cable of 11KV grade of following size direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc. as required. . (For External lighting/power cable) Up to 120 sq. mm 22.1.1 50.0 Metre 628.0 532.2 26610.0 532.2 End Termination: 0.0 |
| 180 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3 C x 120 Sq.mm 23.5.2 4.0 Nos. 21351.0 18094.07 72376.28 18094.07 11/0.433 kV Transformer 24.9 0.0 |
| 181 | Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with Offload Tap Changer/ On Load Tap Changer (OLTC) ( below 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sq.mm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 0C for oil and 40 dg. C up to 200 KVA and 40 0C for oil and 45 0C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max,c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked.Fitting and Accessories : The following fittings shall be provided:-a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers)d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t)Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x).Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps,lugs etc. for termination on HV/MV etc. for all transformers. 0.0 200 kva_Transformer Complete as per above 24.9.1 1.0 Set 497830.0 421889.83 421889.83 421889.83 |
| 182 | Supply and fixing in position the approved \\"shock treatment charts\\" framed in teak wood frame and covered with glass in front as required in two languages (Hindi & English) |
| 183 | Providing and fixing M.V. danger notice plate of 200mm x150mm ,made of mild steel ,at least mm thick ,and vitreous enameled white on both sides,and with inscription in single red colour on front side as required. |
| 184 | Providing and fixing H.T. danger notice plate of 250mm x200mm ,made of mild steel ,at least mm thick ,and vitreous enameled white on both sides,and with inscription in single red colour on front side as required. |
| 185 | Supply and placing of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, including lettered as FIRE with white colour with extra handle at bottom. |
| 186 | Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities. |
| 187 | Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968. |
| 188 | Supply and placing of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and conforming to IS 2217-1963. |
| 189 | SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF MAIN LT/DG/CAPACITOR PANEL Supply, installation, testing and commissioning of 3 phase and Neutral 415V 4 wire free standing floor mounted MV Panel made out of 2mm thick CRCA sheet for main frame and 1.6 mm thick for partions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating 0.7A/Sq.mm) supported with DMC/SMC barriers and color coded with Heat shrinkable sleeves. The metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 36KA and consist of the switchgear as mentioned below . The panel shall be got fabricated from manufactures with CPRI Test certificate only. The PCC shall have atleast two spare cubicles to suit the highest rating outgoing MCCB. The size of all Panel Mounting Meters shall be 96X96 mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every MCCB shall be provided with ON/OFF push buttons, ON/OFF / Trip indication lamps of LED type and shunt trip coils wherever Electrical Interlocking is specified. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. All ACBs/MCCBs 160A and above shall be with Micro processor releases. All CTs/CBCT shall be resin cast type. All MCCBs below 160A shall be with adjustible Thermal magnetic releases. All ACBs/MCCBs shall be Icu=Ics=100%. All McCBs shall be provided with spreader links and Rotary handles. MR 0.0 LT cum capacitor panel. 0.0 Transformer Incomer : 400A, 36KA 4 Pole MCCB with Micro Processor releases for O/C, S/C, U/V and earth fault+400A4Pole AC3 power contactor - 1 Set. 0.0 DG Incomer :300A, 36KA 4 Pole MCCB with Micro Processor releases for O/C, S/C, U/V and earth fault+300A4Pole AC3 power contactor - 1 Set. 0.0 63A, 36KA 4 Pole MCCB_for solar Incomer 0.0 Interlocking : Electrical / Mechanical interlocking between 2 Nos. Incomers in such a way that at a time only one breaker will be ON. 0.0 Busbars : 600A TPN Aluminium Busbar - 1 Set 0.0 Outgoings : 0.0 250A, 36KA 4 Pole MCCB with thermal magnetic releases for O/C, S/C fault protection,Phase barries,spreader and extended ROM - 2 Nos. 0.0 100A, 36KA 4 Pole MCCB with thermal magnetic releases for O/C, S/C fault protection,Phase barries,spreader and extended ROM - 5 Nos._ capacitor , type -5, 3 ext ltg stp & plumbing 0.0 Metering For Incomers : 0.0 CT operated MFM with CTs of ratio 400/5A, Class 1 Accuracy and 15 VA burden and selector switch - 2 Sets. 0.0 LED Phase indication lamps with individuals MCBs and control with toggle switches - 3 Sets 0.0 Capacitor Bank Inbuilt with following:- 0.0 1Set. 63 Amps 36kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit releases +capacitor duty contactor suitable for 20KVAR heavy duty capacitor. 0.0 2Sets. 63 Amps 36kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit releases +capacitor duty contactor suitable for 15KVAR heavy duty capacitor. 0.0 2Sets. 32 Amps 36kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit releases +capacitor duty contactor suitable for 10KVAR heavy duty capacitor. 0.0 2Sets. 20 Amps 36kA 440 volt TP MCCB with heavy duty solid detachable neutral link with overcurrent and short circuit releases +capacitor duty contactor suitable for 5KVAR heavy duty capacitor. 0.0 ON / OFF indicating lamps with MCB as backup protection.-7Sets. 0.0 ON / OFF Push buttons.-7Sets. 0.0 1Set -Stepped relay with auto /manual switch,CTs (APFCR) with 8 steps (each to be of 20/15/10/5KVAR) for automatic /manual power factor correction having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long. 0.0 1No. 20 KVAR with 7% copper detuned reactors capacitor +capacitor duty contactor. 0.0 2Nos. 15 KVARwith 7% copper detuned reactors capacitor +capacitor duty contactor. 0.0 2Nos. 10 KVARwith 7% copper detuned reactors capacitor +capacitor duty contactor. 0.0 2Nos. 5 KVARwith 7% copper detuned reactors capacitor +capacitor duty contactor. 0.0 8 Sets of Push button stations 'RED' and 'GREEN' push buttons for manual operation of capacitors. 0.0 8Nos. selector switches for changing automatic to manual operation of capacitors.(A/M) 0.0 Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit. However, louvers are allowed to facilitate extra cooling. 0.0 NOTE :- 0.0 Electrical /Manual Interlocking Suitable for 1no.250kVA transformer,250kVA DG shall be interlocked in such a way that at a time only one breaker shall be in ON position. 0.0 36kA fault level continous Al Earth Bus shall be part of Panel for full length of panel 0.0 GA drawings shall be got approved by consultant or site incharge. 0.0 Main LT / Capacitor Panel with enclosure & bus bar as described as above and as per specification complete in all respects. 1.0 Set 1008020.5 854254.66 854254.66 854254.66 |
| 190 | MAIN ELECTRICAL PANEL _school building INCOMER 1.1 0.0 1 no _250 Amps 4P MCCB Microprocessor release(36 kA) (With Electronic Trip Unit) (Over Load, Short Circuit & Earth Fault Protection) (Auxiliary & Trip Contact) - 0.0 Spreaders - 0.0 Extended Rotary Operating Mechanism - 0.0 ENCLOSURE & BUSBARS 1.2 0.0 Fabrication 300 Amps, TPN Aluminium Bus Bar, PVC sleeving, control wiring & necessary hardware for LT Panel as well as for functioning of Single / Dual Source Energy Meters & Interlocking. (Each vertical bay shall be equipped with space heater + thermostat, door switch illumination lamp all duly wired) (Back door to be bolted type)+.For selecting the bus bar size 0.7derating factor to be considered. - 0.0 INSTRUMENTS & ACCESSORIES 1.3 0.0 1 No. 96x96 MFM for 3 phase, 4 wire operation with LED display and selector switch with controlled by 3 sets of 2Amp MCB . - 0.0 3Nos.x250/1Amp. Cast resin type CT. - 0.0 3 Nos of LED type phase indicating lamps (RYB) with controlled by 2Amp MCB . - 0.0 OUTGOING 1.4 0.0 2Nos.- 100Amp FP, 36kA MCCB TMD type. - 0.0 Spreaders − 0.0 Extended Rotary Operating Mechanism − 0.0 7 Nos.63A FP 10 kA MCB_C curve - 0.0 4 Nos.63A DP 10 kA MCB_C curve - 0.0 LS Control SP MCB &Neutral link 0.0 MAIN ELECTRICAL PANEL AS DESCRIBED ABOVE._Complete with all 1.0 Set 224810.3 190517.2 190517.2 190517.2 |
| 191 | LIFT PANEL-1 Incoming i 0.0 1 No - 80 Amps 4P ATS 0.0 1 No - 80Amps 4P MCCB (25kA) (with TMD Trip Unit) − 0.0 2 No - Spreaders − 0.0 1 No - Extended Rotary Operating Mechanism − 0.0 Metering (Digital) ii 0.0 1 set -CT Operated Type Multfunction Meter with THD display & RS 485 Port , CTs, CT shorting links, R/Y/B LED indicating lamps. − 0.0 Outgoing_LHS iii 0.0 2 No -63 Amps 4P MCB (10kA) +RCCB (300 mA) − 0.0 4 No -40 Amps DP MCB (10kA) − 0.0 Enclosure / Busbar iv 0.0 1 Set -Fabrication, 200 Amps, 4P Aluminum Bus Bar, PVC Sleeving, Control / Power wiring & hardware. − 0.0 LIFT PANEL -1 _FOR PROPOSED BLOCK AS DESCRIBED ABOVE._Complete with all 1.0 Set 108779.2 92185.76 92185.76 92185.76 |
| 192 | Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:- (i) Speed-1 MPS (ii) Floors-5 (G+4) (iii) Travel -17 Meters (approx.) (iv) Stops & opening- 5 stops and 5 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system 0.0 (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii)Voice announcement system in the car to 0.0 announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided 0.0 13 passenger (884kg) 21.1.1 1.0 set 1684225.72 1427309.93 1427309.93 1427309.93 |
| 193 | UPS OUTPUT PANEL Incoming a) 0.0 1 No - 100 Amps 4P MCCB (36 kA) (with TMD Trip Unit) - 0.0 2 Nos -Spreaders - 0.0 1 No -Extended Rotary Operating Mechanism - 0.0 Metering (Digital) b) 0.0 1 Set -CT Operated Type Multfunction Meter with THD display & RS 485 Port , CTs, CT shorting links, R/Y/B LED indicating lamps. - 0.0 Outgoing c) 0.0 6 Nos -40 Amps 4P MCB (10 kA) _d Curve - 0.0 Enclosure / Busbar d) 0.0 Fabrication,200 Amps, 4P Aluminum Bus Bar, PVC Sleeving, Control / Power wiring & hardware. - 0.0 UPS OUT PUT PANEL FOR PROPOSED BLOCK AS DESCRIBED ABOVE._Complete with all 1.0 Set 94275.3 79894.32 79894.32 79894.32 E A R T H I N G 0.0 |
| 194 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.Lightning Protection_ 5 Nos |
| 195 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.D.G _Neutral - 2 NosTR _ Neutral - 2 Nos LV _ - 2 Nos |
| 196 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.D.G - Body - 2 NosTR_ Body - 2 NosMLTP- Body - 2 NosHT Meter - 2 NosLift - 2 Nos |
| 197 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50metre below ground as strip earth electrode including connection/terminating with nut,bolt,spring,washer etc.as required.(Jointing shall be done by overlapping and with 2sets of GI nut bolt & spring washer spaced at 50 mm) . |
| 198 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 199 | Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connections etc.as required. |
| 200 | Providing and fixing 25 mm x 5 mm GI. strip on surface or in recess for connections etc.as required. |
| 201 | Providing and fixing 6SWG dia GI wire on surface or in recess for loop earthing as required. EXTERNAL LIGHTING 0.0 |
| 202 | Light Fixture |
| 203 | Supply of the 10W Bulkhead delivering minimum system lumen of 900 lm & the luminaire shall be with system efficacy ≥ 90 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK07 along with Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 160 to 280V along with THD ≤ 10% & PF ≥ 0.90. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacturer along with Photo Biological Safety Standard. |
| 204 | Supply, installation, testing and commissioning ofSupply of LED Post Top of 40W made of Corrosion Resistant Die Cast Aluminium Powder coated housing and clear acrylic cover having symmetric light distribution with efficacy of 105Lm/W, CRI > 70, CCT - 4000K/5700K. Total Lumen Output of the product is at least 4200Lm, with Power Factor >0.90, IP-65, LED Used shall be SMD type. Luminaire should have Life of 50,000hrs @ L70B Lumen maintenance, Surge Protection 4kV Internal + 10kV External, THD<10% and an operating Voltage Range of 160 - 270V AC. Suitable for Vertical pole entry mounting. EXTERNAL LIGHTING FEEDER PILLAR: MR 0.0 |
| 205 | SITC Of free standing suitable for out door installation dust & vermin proof feeder pillar made out of CRCA sheet ,required hard ware,duly painted by either two coats of zink /red oxide primer followwed by two coats of synthetic enmel paint for powder coating in grey or required shade . The feeder pillar having Neoprene rubber gasket of not less than 3mm thickness,hingled door with locking arrangement,gland plate.Thickness of sheet shall not be less than 2mm.Sheet metal works shall be processed with seven tank process,200A TPN 415V Electrolytic Cu Conductor bus bar with 100% Neutral (Fixed on 50x50x6mm thick MS Angle iron frame& covered with sheet metal from all sides)and having the following components.depth of panel upto 300 mm Incoming : 0.0 One (1) No. 63A 4P MCB (10KA) +63A 4P 100mA ELCB 0.0 Busbar : 0.0 Electrolytic high conductivity Copper three pole and 100%neutral 100 amps TPN 415V 50Hz.copper bus bars insulated with heat shrinkable PVC sleeves & SMC/DMC supports. 0.0 Outgoings : 0.0 Three (3) Nos. 10 A-32A DP 10KA MCBs. with 10A-32A DP contactor (AC 1 Category with 230V Control Coil) using 1 No. 24 hour astronomical time switch on Auto/Manual arrangement with Auto/Manual selection switch, ON/OFF Push Buttons, Indication lamps & Control fuses etc . 0.0 Five (5) Nos. 10-32 A DP 10KA MCBs. 0.0 Full Set as above 1.0 Set 26860.1 22762.8 22762.8 22762.8 |
| 206 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD -63 MM & ID -51MM Nominal) 15.15.1 200.0 m 136.0 115.25 23050.0 115.25 CCTV SYSTEM 40.0 0.0 |
| 207 | Supply, Installation, Testing & Commissioning of IP CCTV Dome Camera 2 MP @ 25 30 fps @1080 p(1920x1080) IP IR dome camera with 2.8 /3.6 MM Fixed lence |
| 208 | Supply, Installation, Testing & Commissioning of IP CCTV Bullet Camera Camera 2 MP (2560x1920) ,2.8 /3.6 mm fixed lense. |
| 209 | Supply, Installation, Testing & Commissioning of 64 Channel NVR having display split, main screen & second screens etc as required to complete the system. |
| 210 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 190.0 Meter 151.0 127.97 24314.3 127.97 ii 25 mm 1.21.2 1000.0 Meter 168.0 142.37 142370.0 142.37 |
| 211 | Supplying Installation, Testing & Commissioning of twisted pain in existing surfaace/ recessed CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. i 1 run of cable 39.17.1 4500.0 Metre 60.0 50.85 228825.0 50.85 |
| 212 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required |
| 213 | Supply, Installation, Testing & Commissioning 48-Port Gigabit PoE Smart Managed Pro Switch, 8-Port 53 W PowerOver-Ethernet, ProSAFE Lifetime Protection. |
| 214 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC,Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL 4TB (Terabytes) 40.12.1 2.0 Nos. 13943.0 11816.1 23632.2 11816.1 |
| 215 | Supply, Installation, Testing & Commissioning of table desktop PC for visualising the recordings and monitoring SOLAR SYSTEM. 0.0 |
| 216 | Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. SUB HEAD -XII FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) 0.0 |
| 217 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel 28.2.1.2 1.0 Each 250420.0 212220.34 212220.34 212220.34 |
| 218 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 219 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required |
| 220 | Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. |
| 221 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 222 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 223 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required |
| 224 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. PA SYSTEM 28.3 0.0 |
| 225 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 226 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 227 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. CABLING & WIRING 28.5 0.0 |
| 228 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required |
| 229 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 230 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm 28.5.3.2 0.0 |
| 231 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 3500.0 Meter 151.0 127.97 447895.0 127.97 ii 25 mm 1.21.2 R.O Meter 168.0 142.37 142.37 UPS 26.2 0.0 |
| 232 | Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60dbat 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification.Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display :a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency.c) Output: Voltage, frequency, Current. d) Battery: 0.0 Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc.i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity.j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 0.0 30KVA (Each Power module shall be < 10 KVA 26.2.3 1.0 Each 505748.0 428600.0 428600.0 428600.0 |
| 233 | Supply, Installation & commissioning of LED Kishok complete as required. |
| 234 | 32 inches diagonal (HD Ready or Full HD 1920x1080 / 4K UHD depending on tier), Infrared (IR) touch or Capacitive 10-point multi-touch. Android (quad-core ARM processors) for simple displays/wayfinding, or Windows 10/11 (Intel i3/i5) for reception software, visitor management, or integrated peripheral ĒLECTRICAL (TYPE-3 QUARTER) 0.0 POINT WIRING & ACCESSORIES WIRING IN PVC CONDUIT 0.0 |
| 235 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.10.3 185.0 Point 1704.0 1444.07 267152.95 1444.07 |
| 236 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.55.3 109.0 Point 994.0 842.37 91818.33 842.37 |
| 237 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 238 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 239 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 240 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 6 pin 5/6 &15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 241 | Supplying and fixing call bell /buzzer suitable for single phase,230V complete as required as required. |
| 242 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required.(For AC) |
| 243 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 244 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 245 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required. i 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1.14.2 2000.0 Meter 311.0 263.56 527120.0 263.56 ii 2X 4 sq. mm + 1 X 4 sq. mm earth wire 1.14.3 1200.0 Meter 373.0 316.1 379320.0 316.1 iii 2X 6 sq. mm + 1 X 6 sq. mm earth wire 1.14.4 10.0 Meter 482.0 408.47 4084.7 408.47 iv 2X 10 sq. mm + 1 X 6 sq. mm earth wire 1.14.5 R.O Meter 621.0 526.27 526.27 v 4X 10 sq. mm + 2 X 6 sq. mm earth wire 1.14.10 10.0 Meter 1078.0 913.56 9135.6 913.56 vi 4X 16 sq. mm + 2 X 6 sq. mm earth wire 1.14.11 250.0 Meter 1454.0 1232.2 308050.0 1232.2 |
| 246 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 750.0 Meter 151.0 127.97 95977.5 127.97 ii 25 mm 1.21.2 1000.0 Meter 168.0 142.37 142370.0 142.37 iii 32 mm 1.21.3 320.0 Meter 209.0 177.12 56678.4 177.12 iv 40 mm 1.21.4 R.O Meter 257.0 217.8 217.8 v 50 mm 1.21.5 R.O Meter 316.0 267.8 267.8 |
| 247 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i Telephone socket outlet 1.24.6 24.0 Each 168.0 142.37 3416.88 142.37 ii TV.Socket outlet 1.24.7 8.0 Each 168.0 142.37 1138.96 142.37 |
| 248 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 249 | Providing and fixing circular /hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140mm 73mm height top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed in to the cast iron/MS sheet box by means of 3.3mm dia round headed screws,one lock at the corners.Clamp shall be made of 12mm dia MS bar bent to shape as per standard drawing. |
| 250 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 251 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 252 | 3 Module (100 mmX75 mm) |
| 253 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. LIGHTING FIXTURES & FANS 0.0 |
| 254 | LED Batten light (System lumen efficacy ≥120 85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 36 watt 8.10.3 32.0 Each 760.0 644.07 20610.24 644.07 |
| 255 | Supply Installation Testing and Commissioning of 1 x 10 to 12 watt wall mounted mirror light of 600 mm long High Power LED batten made out extruded alumiinium with poly carbonate difusser. The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <20% surge protection of 2.5 kv, 35000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registrationcomplete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required. |
| 256 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 12 -15 watt 8.1.3 172.0 Each 715.0 605.93 104219.96 605.93 |
| 257 | Brush Less Direct Current (BLDC) Fan withoutRemote Supplying, installation, testing & Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Energy efficient 5-star 1200 mm sweep. 9.2.3 40.0 Each 2695.0 2283.9 91356.0 2283.9 |
| 258 | 450 mm sweep heavy duty, Exhaust Fans, 900 rpm, 75 m3 / minute air delivery with 4 blades dynamically balanced impellers, pre lubricated double ball bearing, 130-140 watt power consumption , 50 Hz, 223V-240V, 50 - 60 noise level & 2 hours fiire rating. |
| 259 | Supplying, of 10W LED Bulkhead Light fixture IP66 Complete with aluminium housing ,integrated driver &all accessories as required. TELECOMMUNICATION SYSTEM 0.0 |
| 260 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 250.0 Meter 151.0 127.97 31992.5 127.97 ii 25 mm 1.21.2 50.0 Meter 168.0 142.37 7118.5 142.37 iii 32 mm 1.21.3 R.O Meter 209.0 177.12 177.12 iv 40 mm 1.21.4 R.O Meter 257.0 217.8 217.8 v 50 mm 1.21.5 R.O Meter 316.0 267.8 267.8 |
| 261 | Supply, Installation & commissioning of 50 Pair MDF Box with Koron Module (Tagging Unit) Complete with MS Enclosure and complete as required. 50 pair 1.0 Nos 2491.7 2111.61 2111.61 2111.61 |
| 262 | Supplying and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated ,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
| 263 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ PVC conduit as required. i 1 run of cable 39.17.1 200.0 Meter 60.0 50.85 10170.0 50.85 ii 2 run of cable 39.17.2 R.O Meter 96.0 81.36 81.36 iii 3 run of cable 39.17.3 R.O Meter 131.0 111.02 111.02 MCB DISTRIBTION BOARD 0.0 |
| 264 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way, Double door 2.3.3 1.0 Each 2871.0 2433.05 2433.05 2433.05 |
| 265 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i 6 way (4 + 18), Double door 2.4.2 R.O Each 5299.0 4490.68 4490.68 ii 8 way (4 + 24), Double door 2.4.3 R.O Each 6337.0 5370.34 5370.34 |
| 266 | Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) i 4 way (4 + 12), Double door 2.5.1 R.O Each 7951.0 6738.14 6738.14 ii 8 way (4 + 24), Double door 2.5.2 2.0 Each 10724.0 9088.14 18176.28 9088.14 iii 12way (4 + 36), Double door 2.5.3 8.0 Each 13512.0 11450.85 91606.8 11450.85 |
| 267 | Supplying and fixing 5 A to 32 A rating, 240/415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i Single pole . 2.10.1 240.0 Each 285.0 241.53 57967.2 241.53 ii Triple pole and neutral 2.10.5 10.0 Each 1301.0 1102.54 11025.4 1102.54 |
| 268 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 269 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 A 2.14.2 24.0 Each 2512.0 2128.81 51091.44 2128.81 |
| 270 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 A 2.15.2 8.0 Each 3452.0 2925.42 23403.36 2925.42 ii 63 A 2.15.3 R.O Each 3597.0 3048.31 3048.31 |
| 271 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 272 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 273 | Supplying and fixing Cable End Box (Loose wire box)suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCB DB 2.23.4 1.0 Each 990.0 838.98 838.98 838.98 |
| 274 | Supplying and fixing Cable End Box (Loose wire box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. i For 4 way, Double door TPN MCBDB 2.24.1 R.O Each 1177.0 997.46 997.46 |
| 275 | Supplying and fixing Cable End Box (Loose wire box)suitable for following triple pole and neutral, sheet steel,vertical MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required. CABLE TRAY/DWC HDPE PIPE 0.0 |
| 276 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. i 150 mm width X 50 mm depth X 1.6 mm thickness 4.1.2 R.O Meter 686.0 581.36 581.36 ii 300 mm width X 50 mm depth X 1.6 mm thickness 4.1.4 R.O Meter 866.0 733.9 733.9 iii 450 mm width X 50 mm depth X 1.6 mm thickness 4.1.6 R.O Meter 1243.0 1053.39 1053.39 iv 600 mm width X 50 mm depth X 1.6 mm thickness 4.1.7 R.O Meter 1482.0 1255.93 1255.93 HDPE PIPE 14.15 0.0 |
| 277 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. i 120 mm dia (OD-120 mm & ID-103 mm nominal) 15.15.3 50.0 Meter 264.0 223.73 11186.5 223.73 ii 200 mm dia (OD-200 mm & ID-175 mm nominal) 15.15.5 R.O Meter 580.0 491.53 491.53 |
| 278 | MAIN ELECTRICAL PANEL _RESIDENTIAL building_METERING PANEL INCOMER 1.1 0.0 1 no _100 Amps 4P MCCB Microprocessor release(36 kA) (With Electronic Trip Unit) (Over Load, Short Circuit & Earth Fault Protection) (Auxiliary & Trip Contact) - 0.0 Spreaders - 0.0 Extended Rotary Operating Mechanism - 0.0 ENCLOSURE & BUSBARS 1.2 0.0 Fabrication 200 Amps, TPN Aluminium Bus Bar, PVC sleeving, control wiring & necessary hardware for LT Panel as well as for functioning of Single / Dual Source Energy Meters & Interlocking. (Each vertical bay shall be equipped with space heater + thermostat, door switch illumination lamp all duly wired) (Back door to be bolted type)+.For selecting the bus bar size 0.7derating factor to be considered. - 0.0 INSTRUMENTS & ACCESSORIES 1.3 0.0 1 No. 96x96 MFM for 3 phase, 4 wire operation with LED display and selector switch with controlled by 3 sets of 2Amp MCB . - 0.0 3Nos.x100/1Amp. Cast resin type CT. - 0.0 3 Nos of LED type phase indicating lamps (RYB) with controlled by 2Amp MCB . - 0.0 OUTGOING 1.4 0.0 10 Nos.63A 4P 10 kA MCB_C curve (UNITS & SPARE) - 0.0 2Nos.63A DP 10 kA MCB_C curve COMMON AREA DB & SPARE - 0.0 9_NOS _ KWH _3 PHASE METERS 0.0 LS Control SP MCB &Neutral link 0.0 MAIN ELECTRICAL PANEL AS DESCRIBED ABOVE._Complete with all 1.0 Set 121158.39 102676.6 102676.6 102676.6 E A R T H I N G 0.0 |
| 279 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.MLTP- Body - 2 Nos |
| 280 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50metre below ground as strip earth electrode including connection/terminating with nut,bolt,spring,washer etc.as required.(Jointing shall be done by overlapping and with 2sets of GI nut bolt & spring washer spaced at 50 mm) . |
| 281 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 282 | Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connections etc.as required. |
| 283 | Providing and fixing 25 mm x 5 mm GI. strip on surface or in recess for connections etc.as required. |
| 284 | Providing and fixing 6SWG dia GI wire on surface or in recess for loop earthing as required. CCTV SYSTEM 40.0 0.0 |
| 285 | Supply, Installation, Testing & Commissioning of IP CCTV Dome Camera 2 MP @ 25 30 fps @1080 p(1920x1080) IP IR dome camera with 2.8 /3.6 MM Fixed lence |
| 286 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : i 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 40.11.2 1.0 Nos. 82600.0 70000.0 70000.0 70000.0 ii 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 40.10.2 1.0 Nos. 12799.0 10846.61 10846.61 10846.61 |
| 287 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 200.0 Meter 151.0 127.97 25594.0 127.97 ii 25 mm 1.21.2 R.O Meter 168.0 142.37 142.37 |
| 288 | Supplying Installation, Testing & Commissioning of twisted pain in existing surfaace/ recessed CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. i 1 run of cable 39.17.1 450.0 Metre 60.0 50.85 22882.5 50.85 |
| 289 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required |
| 290 | Supply, Installation, Testing & Commissioning 16-Port Gigabit PoE Smart Managed Pro Switch, 8-Port 53 W Power_x0002_Over-Ethernet, ProSAFE Lifetime Protection. |
| 291 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC,Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL i 4TB (Terabytes) 40.12.1 1.0 Nos. 13943.0 11816.1 11816.1 11816.1 |
| 292 | Supply, Installation, Testing & Commissioning of table desktop PC for visualising the recordings and monitoringCore i5/Ryzen 5, 16GB RAM, Integrated Graphics, Single 21.5\\" FHD Monitor, 600VA UPS. Best for standard SCADA or up to 16 camera streams. FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL) 0.0 |
| 293 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel 28.2.1.2 1.0 Each 250420.0 212220.34 212220.34 212220.34 |
| 294 | Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 295 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 296 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 297 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. PA SYSTEM 28.3 0.0 |
| 298 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP4 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 299 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 300 | Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 Volt ACSupply complete as required. CABLING & WIRING 28.5 0.0 |
| 301 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required |
| 302 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 303 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm 28.5.3.2 150.0 Mtr 97.0 82.2 12330.0 82.2 |
| 304 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 80.0 Meter 151.0 127.97 10237.6 127.97 ii 25 mm 1.21.2 R.O Meter 168.0 142.37 142.37 ĒLECTRICAL (TYPE-5 QUARTER) 0.0 POINT WIRING & ACCESSORIES WIRING IN PVC CONDUIT 0.0 |
| 305 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.10.3 36.0 Point 1704.0 1444.07 51986.52 1444.07 |
| 306 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.55.3 23.0 Point 994.0 842.37 19374.51 842.37 |
| 307 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 308 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 309 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 310 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 6 pin 5/6 &15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 311 | Supplying and fixing call bell /buzzer suitable for single phase,230V complete as required as required. |
| 312 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required.(For AC & GEYSER) |
| 313 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 314 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 315 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required. i 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 1.14.2 350.0 Meter 311.0 263.56 92246.0 263.56 ii 2X 4 sq. mm + 1 X 4 sq. mm earth wire 1.14.3 100.0 Meter 373.0 316.1 31610.0 316.1 iii 2X 6 sq. mm + 1 X 6 sq. mm earth wire 1.14.4 10.0 Meter 482.0 408.47 4084.7 408.47 iv 2X 10 sq. mm + 1 X 6 sq. mm earth wire 1.14.5 R.O Meter 621.0 526.27 526.27 v 4X 10 sq. mm + 2 X 6 sq. mm earth wire 1.14.10 25.0 Meter 1078.0 913.56 22839.0 913.56 vi 4X 16 sq. mm + 2 X 6 sq. mm earth wire 1.14.11 R.O Meter 1454.0 1232.2 1232.2 |
| 316 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 150.0 Meter 151.0 127.97 19195.5 127.97 ii 25 mm 1.21.2 200.0 Meter 168.0 142.37 28474.0 142.37 iii 32 mm 1.21.3 25.0 Meter 209.0 177.12 4428.0 177.12 |
| 317 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. i Telephone socket outlet 1.24.6 6.0 Each 168.0 142.37 854.22 142.37 ii TV.Socket outlet 1.24.7 6.0 Each 168.0 142.37 854.22 142.37 |
| 318 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 319 | Providing and fixing circular /hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140mm 73mm height top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding top lid shall be screwed in to the cast iron/MS sheet box by means of 3.3mm dia round headed screws,one lock at the corners.Clamp shall be made of 12mm dia MS bar bent to shape as per standard drawing. |
| 320 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 321 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. i 3 Module (100 mmX75 mm) 1.27.2 27.0 Each 384.0 325.42 8786.34 325.42 |
| 322 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. LIGHTING FIXTURES & FANS 0.0 |
| 323 | Supply Installation Testing and Commissioning of 1 x 36 to 40 watt surface / wall mounted 1200 mm long High Power LED batten made out extruded alumiinium with poly carbonate difusser .The LED lamps should have a system efficacy of 120 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <10% surge protection of 2.5 kv, 50000 hours LED life @ L70 and driver efficiency > 85%.Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registration complete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required. |
| 324 | Supply Installation Testing and Commissioning of 1 x 10 to 12 watt wall mounted mirror light of 600 mm long High Power LED batten made out extruded alumiinium with poly carbonate difusser. The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <20% surge protection of 2.5 kv, 35000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registrationcomplete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required. |
| 325 | Supplying, installation, testing & Commissioning of surface type 15W to 16W LED Round Downlight with pressure die-cast aluminium heat sink & glarefree opal Diffuser. The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <10% surge protection of 2.5 kv, 50000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registration complete with all accessories etc with 1.5 sq mm |
| 326 | Supply, Installation, testing & commissioning of wall bracket type LED fitting with Decorative, wall mounting, SS finish fixture with opal PC diffuser suitable for 9 W LED lamp E27 base, The LED lamps should have a system efficacy of 100 lumens/watt having CCT of 5700 K to 6500 K, CRI >80, and driver would have a power factor >0.9,THD <20% surge protection of 2.5 kv, 35000 hours LED life @ L70 and driver efficiency > 85%. Luminen shall be as per certifications LM 79 & LM80 issued by manufacturer & BIS registrationcomplete with all accessories etc with 1.5 sq mm FRLS PVC insulated copper cond. single core cable and earthing etc. complete as required.. |
| 327 | Supplying, installation, testing & Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Energy efficient 5-star 1200 mm sweep. 9.2.3 9.0 Each 2695.0 2283.9 20555.1 2283.9 |
| 328 | Supplying, Installation, Testing & Commissioning Exhaust Fans of the following sizes & specifications suitable for single Phase 230 V supply including but not limited to providing & connecting with suitable & required length PVC insulated wiring & plugs to the exising socket & making openings / holes / required fixing arrangement & making good the damage complete as per manufactures specifications & direction of the Engineer - in - charge. 450 mm sweep heavy duty, Exhaust Fans, 900 rpm, 75 m3 / minute air delivery with 4 blades dynamically balanced impellers, pre lubricated double ball bearing, 130-140 watt power consumption , 50 Hz, 223V-240V, 50 - 60 noise level & 2 hours fiire rating. - 6.0 Each 9289.31 7872.3 47233.8 7872.3 TELECOMMUNICATION SYSTEM 0.0 |
| 329 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 1.21.2 50.0 Meter 168.0 142.37 7118.5 142.37 |
| 330 | Supply, Installation & commissioning of 50 Pair MDF Box with Koron Module (Tagging Unit) Complete with MS Enclosure and complete as required. 10 pair 1.0 Nos 2076.41 1759.67 1759.67 1759.67 |
| 331 | Supplying and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated ,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. |
| 332 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ PVC conduit as required. 1 run of cable 39.17.1 50.0 Meter 60.0 50.85 2542.5 50.85 MCB DISTRIBTION BOARD 0.0 |
| 333 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way, Double door 2.3.3 2.0 Each 2871.0 2433.05 4866.1 2433.05 |
| 334 | Supplying and fixing 5 A to 32 A rating, 240/415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i Single pole . 2.10.1 20.0 Each 285.0 241.53 4830.6 241.53 ii Triple pole and neutral 2.10.5 2.0 Each 1301.0 1102.54 2205.08 1102.54 |
| 335 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 336 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 A 2.14.2 2.0 Each 2512.0 2128.81 4257.62 2128.81 |
| 337 | Supplying and fixing Cable End Box (Loose wire box)suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. i For 14 way, Double door SPN MCB DB 2.23.4 2.0 Each 990.0 838.98 1677.96 838.98 |
| 338 | Supplying and fixing Cable End Box (Loose wire box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. i For 4 way, Double door TPN MCB DB 2.24.1 R.O Each 1177.0 997.46 997.46 |
| 339 | Supplying and fixing Cable End Box (Loose wire box)suitable for following triple pole and neutral, sheet steel,vertical MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required. CABLE TRAY/DWC HDPE PIPE 0.0 HDPE PIPE 14.15 0.0 |
| 340 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. i 120 mm dia (OD-120 mm & ID-103 mm nominal) 15.15.3 20.0 Meter 264.0 223.73 4474.6 223.73 ii 200 mm dia (OD-200 mm & ID-175 mm nominal) 15.15.5 R.O Meter 580.0 491.53 491.53 |
| 341 | MAIN ELECTRICAL PANEL _RESIDENTIAL building_METERING PANEL INCOMER 1.1 0.0 1 no _100 Amps 4P MCCB Microprocessor release(36 kA) (With Electronic Trip Unit) (Over Load, Short Circuit & Earth Fault Protection) (Auxiliary & Trip Contact) - 0.0 Spreaders - 0.0 Extended Rotary Operating Mechanism - 0.0 ENCLOSURE & BUSBARS 1.2 0.0 Fabrication 200 Amps, TPN Aluminium Bus Bar, PVC sleeving, control wiring & necessary hardware for LT Panel as well as for functioning of Single / Dual Source Energy Meters & Interlocking. (Each vertical bay shall be equipped with space heater + thermostat, door switch illumination lamp all duly wired) (Back door to be bolted type)+.For selecting the bus bar size 0.7derating factor to be considered. - 0.0 INSTRUMENTS & ACCESSORIES 1.3 0.0 1 No. 96x96 MFM for 3 phase, 4 wire operation with LED display and selector switch with controlled by 3 sets of 2Amp MCB . - 0.0 3Nos.x100/1Amp. Cast resin type CT. - 0.0 3 Nos of LED type phase indicating lamps (RYB) with controlled by 2Amp MCB . - 0.0 OUTGOING 1.4 0.0 3Nos.40/63A DP 10 kA MCB_C curve UMIT DB & SPARE - 0.0 9_NOS _ KWH _3 PHASE METERS 0.0 LS Control SP MCB &Neutral link 0.0 MAIN ELECTRICAL PANEL AS DESCRIBED ABOVE._Complete with all 1.0 Set 35634.82 30199.0 30199.0 30199.0 E A R T H I N G 0.0 |
| 342 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.MLTP- Body - 2 Nos |
| 343 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50metre below ground as strip earth electrode including connection/terminating with nut,bolt,spring,washer etc.as required.(Jointing shall be done by overlapping and with 2sets of GI nut bolt & spring washer spaced at 50 mm) . |
| 344 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 345 | Providing and fixing 25 mm x 5 mm Cu. strip on surface or in recess for connections etc.as required. |
| 346 | Providing and fixing 25 mm x 5 mm GI. strip on surface or in recess for connections etc.as required. |
| 347 | Providing and fixing 6SWG dia GI wire on surface or in recess for loop earthing as required. CCTV SYSTEM 40.0 0.0 |
| 348 | Supply, Installation, Testing & Commissioning of IP CCTV Dome Camera 2 MP @ 25 30 fps @1080 p(1920x1080) IP IR dome camera with 2.8 /3.6 MM Fixed lence |
| 349 | Supplying Installation Testing and Commissioning of 2MP Fixed Lens IP IR Outdoor Bullet Camera having following specifications and features etc |
| 350 | Supply, Installation, Testing & Commissioning of IP CCTV Bullet Camera Camera 2 MP (2560x1920) ,2.8 /3.6 mm fixed lense. |
| 351 | 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen:1/4/8/9/16 |
| 352 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm 1.21.1 35.0 Meter 151.0 127.97 4478.95 127.97 ii 25 mm 1.21.2 R.O Meter 168.0 142.37 142.37 |
| 353 | Supplying Installation, Testing & Commissioning of twisted pain in existing surfaace/ recessed CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 39.17.1 80.0 Metre 60.0 50.85 4068.0 50.85 SANITARY INSTALLATIONS 0.0 |
| 354 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 17.1.1 17.0 Each 6767.4 6701.6 7773.9 6587.97 111995.49 6587.97 |
| 355 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat as lid,10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. W.C. pan with ISI Marked white solid plastic seat and lid. 17.2.1 52.0 Each 6515.55 6452.2 7484.6 6342.8 329825.6 6342.8 |
| 356 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid 17.3.1 16.0 Each 8006.6 7928.7 9197.3 7794.31 124708.96 7794.31 |
| 357 | Providing and fixing wash basin with CI brackets,15mm C.P. brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings & brackets,cutting and making good the walls wherever required. i White Vitreous china wash basin size 630x450 mm with a pair of 15mm CP brass pillar taps. 17.7.1 96.0 Each 2648.85 2623.1 3042.8 2578.62 247547.52 2578.62 ii White Vitreous china wash basin size 630x450 mm with a single 15mm CP brass pillar tap. 17.7.2 55.0 Each 2226.35 2204.7 2557.5 2167.32 119202.6 2167.32 |
| 358 | Providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board 17.10.1 0.0 i 510 X 1050 mm bowl depth 225mm 17. 10.1.2 10.0 Each 7514.65 7441.5 8632.1 7315.4 73154.0 7315.4 |
| 359 | Providing and fixing white vitreous china laboratory sink with CI brackets,CP brass chain with rubber plug,40mm CP brass waste and 40mm CP brass trap with necessary CP brass unions complete including painting of fittings and brackets,cutting and making good the walls wherever required. i Size 600x450x200mm 17.11.2 35.0 Each 6585.8 6521.7 7565.2 6411.18 224391.3 6411.18 |
| 360 | Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete . i Semi rigid pipe 17.28.1 0.0 a) 40 mm dia 17.28.1.2 15.0 Each 116.7 115.6 134.1 113.61 1704.15 113.61 |
| 361 | Providing and fixing mirror of superior glass (of approved quality) and of required shape & size with plastic moulded frame of approved make & shade with 6mm thick hard board backing. i Rectangular shape 453 X 357 mm 17. 32.2 2.0 Each 1361.8 1348.5 1564.3 1325.69 2651.38 1325.69 ii Rectangular shape 1500 X 450 mm 17. 32.4 75.0 Each 2093.0 2072.6 2404.2 2037.51 152813.25 2037.51 |
| 362 | Providing and fixing 600x120x5mm glass shelf with edges round off,supported on anodised aluminium angle frame with CP brass brackets and guard rail complete with 40mm long screws,rawl pugs etc. complete. Providing and fixing toilet paper holder. CP brass. 17.34 0.0 i CP brass 17. 34.1 77.0 Each 803.7 795.9 923.2 782.39 60244.03 782.39 |
| 363 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with concealed fittings arrangement of approved quality & colour. 750x20mm size. i 600mm long towel rail with total length of 645mm,width 78mm & effective height of 88mm,weighing not less than 190gms. 17.73.2 32.0 Each 708.95 702.1 814.4 690.15 22084.8 690.15 |
| 364 | Providing and fixing brass bib cock of approved quality. i 15 mm nominal bore. 18.15.1 15.0 Each 353.25 349.8 405.8 343.88 5158.2 343.88 |
| 365 | Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms. i 15 mm nominal bore. 18.51.1 15.0 Each 798.95 791.2 917.8 777.77 11666.55 777.77 |
| 366 | Providing and fixing C.P.brass bottle trap 32mm size bottle trap of approved quality & make as approved by Engineer-in-charge. |
| 367 | Providing and fixing C.P.brass Single lever telephonic wall mixer of approved quality & make as approved by Engineer-in-charge. 15 mm nominal bore. 18.0 Each 6940.75 6873.2 7972.9 6756.72 121620.96 6756.72 |
| 368 | Cutting chases in brick mansonry walls for following diameter sand cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.5mm nominal size), incliding necessary plaster and pointing in cement mortal 1:4 (1 cement :4 coarse sand): i 100mm dia 17.61.1 50.0 Metre 713.2 706.3 819.3 694.29 34714.5 694.29 ii 75mm dia 17.61.2 50.0 Metre 513.25 508.3 589.6 499.64 24982.0 499.64 iii 50mm dia 17.61.3 20.0 Metre 336.0 332.7 385.9 327.09 6541.8 327.09 |
| 369 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610x390x370mm having pre & post flushing with water(250ml & 500 ml consumption),having water inlet from back side,including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in -charge. |
| 370 | Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. The Pipes will be supported with threaded G I rods & clamps on 50x50x5 mm slotted angle. The cost will include all support arrangements. The work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg-in-charge at site. 0.0 i 110mm outer dia 600.0 Metre 1400.0 1186.44 711864.0 1186.44 ii 75mm outer dia 30.0 Metre 970.0 822.03 24660.9 822.03 |
| 371 | Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. i 40mm outer dia 330.0 Metre 400.0 338.98 111863.4 338.98 ii 50mm outer dia 170.0 Metre 490.0 415.25 70592.5 415.25 iii 63mm outer dia 40.0 Metre 570.0 483.05 19322.0 483.05 |
| 372 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. i a) 100 mm inlet and 100 mm outlet. 0.0 ( with 127dia Glossy CP Grating 134.0 Each 890.0 754.24 101068.16 23 ii b) 100 mm inlet and 75 mm outlet. 0.0 (with 102 mm dia CP Glossy Grating 10.0 Each 800.0 677.97 6779.7 23 |
| 373 | Providing & fixing 110m x 50mm waste with PVC reducer including cutting chases in floor, cutting RCC slab complete as required. |
| 374 | Providing & fixing Health Faucet with 8mm dia, 1M long PVC tube and wall hook |
| 375 | Providing & fixing Sink Mixer with Swinging Casted Spout (Wall Mounted) with 450mm long copper pipes & brass nuts. |
| 376 | Providing & fixing wall mounted 35 mm dia.,600mm long grab bar including cutting & making good the walls |
| 377 | Providing in position storage type hot water electrical geyser( vertical or horizontal-1.5 kw) including making connection in all respects.- 25 litres capacity. 30.0 Each 14000.0 11864.41 355932.3 11864.41 |
| 378 | Supply installation testing and commissioning R.O.water purifier comprising 5 micron filter and UV steriliser on cold water supply to work on single phase 230 volts 50 HZ AC power supply with capacity 120 lph.- WATER SUPPLY 0.0 |
| 379 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 0.0 i 20 mm nominal outer dia pipes. 18.7.2 180.0 Metre 335.0 331.7 384.8 326.12 58701.6 326.12 ii 25 mm nominal outer dia pipes. 18.7.3 200.0 Metre 401.55 397.6 461.2 390.9 78180.0 390.9 iii 32 mm nominal outer dia pipes. 18.7.4 350.0 Metre 518.75 513.7 595.9 505.0 176750.0 505.0 iv 40 mm nominal outer dia pipes. 18.7.5 440.0 Metre 702.95 696.1 807.5 684.31 301096.4 684.31 v 50 mm nominal outer dia pipes. 18.7.6 480.0 Metre 934.15 925.1 1073.1 909.38 436502.4 909.38 |
| 380 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 0.0 i 20 mm nominal outer dia pipes. 18.8.2 1350.0 Metre 537.6 532.4 617.6 523.35 706522.5 523.35 ii 25 mm nominal outer dia pipes. 18.8.3 350.0 Metre 627.25 621.1 720.5 610.62 213717.0 610.62 iii 32 mm nominal outer dia pipes. 18.8.4 180.0 Metre 739.3 732.1 849.2 719.7 129546.0 719.7 |
| 381 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete as per direction of engineer in charge. . External Work 0.0 i 20 mm nominal outer dia pipes. 18.9.2 20.0 Metre 274.3 271.6 315.1 267.03 5340.6 267.03 ii 25 mm nominal outer dia pipes. 18.9.3 380.0 Metre 355.4 351.9 408.2 345.98 131472.4 345.98 iii 32 mm nominal outer dia pipes. 18.9.4 330.0 Metre 438.6 434.3 503.8 426.97 140900.1 426.97 iv 40 mm nominal outer dia pipes. 18.9.5 190.0 Metre 563.1 557.6 646.8 548.12 104142.8 548.12 v 50 mm nominal outer dia pipes. 18.9.6 80.0 Metre 794.25 786.5 912.3 773.19 61855.2 773.19 vi 65 mm nominal outer dia pipes. 18.9.7 880.0 Metre 1674.4 1658.1 1923.4 1630.0 1434400.0 1630.0 vii 80 mm nominal outer dia pipes. 18.9.6 30.0 Metre 2166.35 2145.3 2488.5 2108.91 63267.3 2108.91 |
| 382 | Making connection of GI distribution branch with GI main of following sizes by providing and fixing tee,including cutting and threading the pipes etc, complete. 25 to 40mm nominal bore 18.13.1 1.0 Each 911.9 903.0 1047.5 887.72 887.72 887.72 |
| 383 | Fixing water meter and stop cock in GI pipe line including cutting and threading the pipe and making long screws etc. Complete (cost of water meter and stop cock to be paid separately). |
| 384 | Providing and fixing brass stop cock of approved quality. i 15 mm nominal bore 8.0 Each 406.85 402.9 467.4 396.06 3168.48 396.06 ii 20 mm nominal bore 8.0 Each 462.5 458.0 531.3 450.24 3601.92 450.24 |
| 385 | Providing and fixing gunmetal gate valve with CI wheel of approved quality(screwed end). i 25 mm dia nominal bore 18.17.1 14.0 Each 622.4 616.3 714.9 605.9 8482.6 605.9 ii 20 mm dia nominal bore 18.17.1A 74.0 Each 540.0 534.7 620.3 525.63 38896.62 525.63 iii 32 mm dia nominal bore 18.17.2 50.0 Each 689.6 682.9 792.2 671.32 33566.0 671.32 iv 40 mm dia nominal bore 18.17.3 20.0 Each 826.1 818.1 949.0 804.2 16084.0 804.2 v 50 mm dia nominal bore 18.17.4 18.0 Each 1026.7 1016.7 1179.4 999.43 17989.74 999.43 vi 65 mm nominal outer dia pipes. 18.17.5 12.0 Each 1746.15 1729.2 2005.9 1699.85 20398.2 1699.85 vii 80 mm nominal outer dia pipes. 18.17.6 2.0 Each 2604.6 2579.3 2992.0 2535.49 5070.98 2535.49 |
| 386 | Providing and fixing gunmetal non return valve of approved quality(screwed end). i 50 mm nominal bore -Vertical 18.19.4 2.0 Each 1445.15 1431.1 1660.1 1406.83 2813.66 1406.83 ii 65 mm nominal bore -Vertical 18.19.5 6.0 Each 2291.6 2269.3 2632.4 2230.79 13384.74 2230.79 |
| 387 | Providing and fixing P.V.C connection with brass union. 45cm length. 15mm nominal bore 250.0 Each 97.75 96.8 112.3 95.16 23790.0 95.16 |
| 388 | Providing and fixing CP shower rose with 15 or 20mm inlet 100mm diameter 18.22.1 18.0 Each 193.95 192.1 222.8 188.81 3398.58 188.81 |
| 389 | Providing & placing on terrace (at all floor levels) polyethylene water storage tank IS 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet & overflow pipes but without fittings and the base support for tank. |
| 390 | Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931. 15 mm nominal bore 18.53.1 250.0 Each 574.3 568.7 659.7 559.07 139767.5 559.07 |
| 391 | Providing and fixing C.P.brass extension nipple(size 15mmx50mm) of approved make and quality as per direction of Engineer-in -charge. |
| 392 | Providing, fixing, installation, testing and commissioning of Solar Hot Water indirect Heating system using approved type of heating liquid medium comprising of flat plate solar panels, with single sheet absorber fin ,screw less construction of panel,including all interconnecting insulated GI piping, primary and secondary recirculation pumps, pressure type insulated hot water tank wit PUF insulation, sacrificial magnesium anode with steel core including valves on inlet, outlet, Y strainer and a water meter on the inlet, air release valve all mounted on galvanized MS sections complete as required with connection with existing piping. (connect the system to hot water mixing tank via 50 mm dia pipe) Supply, Instalation, Testing & Commissioning of 100 LPD flat plate solar collector panels of 2 x 1m size approx. the panels enclosed in insulated collected boxes with single piece toughened glass 3.5mm thick and fixed with heat resistant.panel Should have a single sheet absorber and screwless design. 0.0 a) 100 lpd MS Pressurised tank for re-circulation 0.0 b) Inter-connected insulated GI piping insulated with 9mm thick nitrile rubber heat resistant insulation sections and valves with outer mechanical protection of aluminium sheet cladding. 0.0 Solar panel as described above 10.0 Each 80000.0 67796.61 677966.1 67796.61 |
| 393 | Providing & fixing 12mm thick nitryl rubber insulation on hot water exposed pipes including providing and fixing 24 SWG Al. sheet metal cladding over pipe insulation, 50mm overlapped and hold the same with self-tapping screws and all joints to be sealed with sealent (tarfelt strip) complete as required. 0.0 i 20 mm nominal outer dia pipes. 30.0 Metre 380.0 322.03 9660.9 322.03 ii 25 mm nominal outer dia pipes. 30.0 Metre 450.0 381.36 11440.8 381.36 iii 32 mm nominal outer dia pipes. 40.0 Metre 500.0 423.73 16949.2 423.73 iv 40 mm nominal outer dia pipes. 40.0 Metre 560.0 474.58 18983.2 474.58 |
| 394 | Providing, fixing, testing & commissioning of vertical FRP body pressure filter complete with initial charge of filter media frontal piping with valves. Including testing kit, complete as required.(Location pump room for domestic water near UG tank). Filter for Domestic Water. 0.0 Test pressure 6Kg/Sq.cm 0.0 Capacity 3 LPS. 0.0 Filter as described above 1.0 Set 280000.0 237288.14 237288.14 237288.14 |
| 395 | Supply, installation, testing & commissioning of chlorine dosing system consisting of one FRP/ HDPE tank of 100 liters capacity with a positive displacement diaphragm Dosing pump with a variable flow rate of 0-12 LPH. The motor shall be suitable for operation at 240 V /one phase/ 50 Hertz supply. The pump shall be supplied complete with necessary poly propylene piping, valves, strainers & injection fittings for system to dose solution to the feed line. The pump shall be. (Location pump room for domestic water near UG tank). |
| 396 | Providing, fixing, testing & commissioning of FRP body water softener with frontal piping valves, complete with Resin, Hydraulic Brine Injector, HDPE Brine tank of capacity one generation, mixing motor and all other accessories complete as required. a) Softner for domestic water. Location -Plant Room for domestic water near UG tank. 0.0 Input water Hardness 700 Mg/L ( Max-Appx. )-Exact hardness will be as per tubewell water analysys report. 0.0 Output water Hardness 70 ppm 0.0 Regeneration Cycle After 1.0 lac lts 0.0 Test Pressure 6 Kg. Sq.cm. 0.0 Capacity 3.0 lps 0.0 Softner as described above Capacity 6 LPS 1.0 Set 380000.0 322033.9 322033.9 322033.9 |
| 397 | Providing & fixing fully submersible sump pumps for dewatering with C.I casing & shaft suitable for operation on 400 / 440 V pH 50 cycle A/C power supply.Cyclic operations shall be provided for the pumps. Sump Pumps( For plant room Drainage ) 0.0 Flow rate(each pump) = 3 LPS 0.0 Head = 12 M 0.0 No of pumps = 2(1 working,1 standby) 0.0 RPM = 2900 0.0 Solid Handelling = 20 mm 1.0 Set 150000.0 127118.64 127118.64 127118.64 |
| 398 | Supplying, installing, testing & commissioning Horizontal centrifugal pump set with C.I. casing, Bronze Impeller, SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM electric motor,100 mm dia pressure guage, G.M. isolation cock complete as required. Cyclic operations shall be provided for the pumps. i Raw water Pumps a) 0.0 Flow rate(each pump) = 3 LPS 0.0 Head = 35 M 0.0 No of pumps = 2(1 working,1 standby) 0.0 RPM = 2900 0.0 Pumps as described above 1.0 Set 150000.0 127118.64 127118.64 127118.64 ii Domestic water Lifting Pumps b) 0.0 Flow rate(each pump) = 4 LPS 0.0 Head = 45 M 0.0 No of pumps = 2(1 working,1 standby) 0.0 RPM = 2900 0.0 Pumps as described above 1.0 Set 180000.0 152542.37 152542.37 152542.37 |
| 399 | Design, manufacture, supply, installation, testing and commissioning of the following intergrated, cubicle type, dead front, extensible, sheet steel control panel anchoring the panel to the foundation. The panel shall be duly powder coated and suitable for 500 volts, 50 cycles, 4 wire supply. Quoted price shall include 25 mm thick rubber mats over 50mm thick wood platform, wiring, cabling cable tray,control wiring and copper earthing from control panel to various equipment like motor starters, pump motor, etc. The panel shall have separate compartments for bus bar and cable alleys.The following components and accessories shall be mounted within each control panel. (For raw water pumps, domestic water lifting, sump pumps for plant room drainage). One No. Incoming incoming MCCB complete with the following: 0.0 i. Voltmeter with selector switch and fuses. 0.0 ii. Ammeter with CT's and selector switch. 0.0 iii. Over voltage and under voltage tripping mechanism for persistent voltage fluctuations of ± 10% of the rated voltage for more than 5 minutes. 0.0 iv CT operated over current and earth fault realy (IDMT) with indicating lamps. 0.0 v. Phase indicating lamps with toggle switches. 0.0 vi. Indication lamps for ON/OFF/TRIP starters of motor. 0.0 Copper bus bar sleeves type, rated for three phase & neurtal phase bus bar shall have maximum current density of 1 amps per sq.cm. and the neutral bus bar of not less than 50% capacity. 0.0 OUTGOING: 0.0 Outgoing feeders with starters with Single Phase Preventor and out going feeders to domestic water pump motor(2Nos.-1 working,1 standby). The compartment shall contain CT operated ammeter with selector switch and an indicating lamp with fuse and toggle switch for`ON'/`TRIP'status of motor. 0.0 Outgoing feeders with starters with Single Phase Preventor and out going feeders to raw water pump motor(2Nos.-1 working,1 standby). The compartment shall contain CT operated ammeter with selector switch and an indicating lamp with fuse and toggle switch for`ON'/`TRIP'status of motor. 0.0 Starter with single phase preventer and outgoing feeder to sump pumps for plant room drainage (2Nos.-1 working,1 standby). The compartment shall contain CT operated ammeter and an indicating lamp with fuse and toggle switch for `ON'/`TRIP' status of pump motors. 0.0 Necessary cable alleys space for spare switches, internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating. 0.0 All MCCB's to be suitable for motor duty 0.0 Control Panel as described above. 1.0 Set 300000.0 254237.29 254237.29 254237.29 DRAINAGE 0.0 |
| 400 | Providing & fixing on wall face unplasticised -Ragid PVC rain water pipes conforming to IS ; 13592 Tyape A included jointing with seal ring conforning to IS ; 5382 leaving 10 mm gap for thermal expansion. a)110 mm diameter 12.41.2 800.0 Metre 377.4 373.7 433.5 367.39 293912.0 367.39 |
| 401 | Providing, fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised - Rigid PVC rain water pipes conforming to IS ; 13592 Type A including jointing with seal ring conforming to IS ; 5382 leaving 10 mm gap for thermal expansion. i a)Coupler-110mm diameter 12.42.1.2 150.0 Each 136.15 134.8 156.4 132.54 19881.0 132.54 ii b)Bend-87.5deg-110mm diameter 12.42.5.2 60.0 Each 150.35 148.9 172.7 146.36 8781.6 146.36 iii c)Shoe-110mm shoe 12.42.6.2 60.0 Each 131.85 130.6 151.5 128.35 7701.0 128.35 |
| 402 | Providing & fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete. i 110mm dia 12.43.2 400.0 Each 371.3 367.7 426.5 361.46 144584.0 361.46 |
| 403 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighting not less than 440 grams. |
| 404 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : i 100mm diameter pipe 19.2.1 50.0 Metre 964.75 955.4 1108.3 939.17 46958.5 939.17 ii 150 mm diameter pipe 19.2.2 300.0 Metre 1179.9 1168.4 1355.3 1148.57 344571.0 1148.57 iii 200 mm diameter pipe 19.2.3 50.0 Metre 1375.45 1362.1 1580.0 1338.98 66949.0 1338.98 iv 250 mm diameter pipe 19.2.4 1300.0 Metre 1590.55 1575.1 1827.1 1548.38 2012894.0 1548.38 |
| 405 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design : i 300 mm diameter pipe 19.3.5 300.0 Metre 1173.4 1162.0 1347.9 1142.24 342672.0 1142.24 |
| 406 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed ,within a lead of 50m. i All kinds of soil 2.8.1 800.0 Cum 260.3 257.8 299.0 253.4 202720.0 253.4 |
| 407 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth,including consolidating each deposited layer by ramming,watering,etc. and disposing of surplus excavated soil as directed ,within a lead of 50m. i Pipes. cables exceeding 80mm dia but not exceeding 300mm dia. 2. 10.1.2 1700.0 Metre 352.15 348.7 404.5 342.81 582777.0 342.81 |
| 408 | Extra for Excavating trenches for pipes,cables etc in ordinary/hard rock exceeding 1.5m in depth but not exceeding 3m(rate is over corresponding basic item for depth upto 1.5metre). Ordinary rock. i Pipes. cables exceeding 80mm dia but not exceeding 300mm dia. 2. 14.1.1 200.0 Metre 729.8 722.7 838.3 710.45 142090.0 710.45 |
| 409 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 410 | Providing and laying light duty non-pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete: i 150 mm dia. R.C.C. pipe 200.0 Metre 556.5 551.1 639.3 541.7 108340.0 541.7 ii 250 mm dia. R.C.C. pipe 550.0 Metre 899.8 891.0 1033.6 875.94 481767.0 875.94 iii 300 mm dia. R.C.C. pipe 300.0 Metre 994.3 984.6 1142.1 967.94 290382.0 967.94 |
| 411 | Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. i 150x100mm size P type 0.0 with common burnt clay F.P.S. (non modular) bricks of class designation 7.5. 19.4.2.1 4.0 Each 2734.2 2707.6 3140.8 2661.7 10646.8 2661.7 ii 180x150mm size P type 0.0 with common burnt clay F.P.S. (non modular) bricks of class designation 7.5. 19.4.3.1 20.0 Each 2802.15 2774.9 3218.9 2727.85 54557.0 2727.85 |
| 412 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregrate 40mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement & making channels in cement concrete 1:2:4 mix (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80cm and 45cm deep including C.I. cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) 19.7.1 0.0 i Withcommon burnt clay FPS (non modular)bricks of class designation 7.5 19.7.1.1 14.0 Each 12770.55 12646.3 14669.7 12431.95 174047.3 12431.95 Inside size 120x90cm and 90cm deep including C.I. cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) 19.7.2 0.0 ii Withcommon burnt clay FPS (non modular)bricks of class designation 7.5. 19.7.2.1 13.0 Each 26405.5 26148.6 30332.4 25705.38 334169.94 25705.38 |
| 413 | Extra for depth for manholes i Size 90x80 cm 19.8.1 0.0 Withcommon burnt clay FPS (non modular)bricks of class designation 7.5 19.8.1.1 6.0 Metre 8825.4 8739.5 10137.8 8591.4 51548.4 8591.4 ii Size 120x90cm 19.8.2 0.0 With common burnt clay FPS (non modular)bricks of class designation 7.5 19.8.2.1 6.0 Metre 10585.5 10482.5 12159.7 10304.83 61828.98 10304.83 |
| 414 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 0.0 i With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.9.1.1 1.0 each 8638.75 8554.7 9923.5 8409.7 8409.7 8409.7 |
| 415 | Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m i With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.10.1 1.0 metre 4911.8 4864.0 5642.2 4781.57 4781.57 4781.57 |
| 416 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : i 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.11.1 0.0 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.11.1.1 1.0 each 16560.8 16399.7 19023.7 16121.7 16121.7 16121.7 |
| 417 | Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.12.1 1.0 metre 6362.65 6300.7 7308.8 6193.95 6193.95 6193.95 |
| 418 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : i 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.13.1 0.0 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.13.1.1 1.0 each 35380.05 35035.8 40641.5 34441.97 34441.97 34441.97 |
| 419 | Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : i With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 19.14.1 1.0 metre 15028.55 14882.3 17263.5 14630.08 14630.08 14630.08 |
| 420 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263mm and width as 165mm with minimum 112 mm space between protruded legs having 2mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistant test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manhole with 30x20x15 cm cement concrete block 1:3:6 (1cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 421 | Providing and fixing in position pre-cast RCC manhole cover and frame of required shape & approved quality Circular shape 560 mm internal diameter-EHD-35 19.19.4.1 8.0 Each 2123.8 2103.1 2439.6 2067.49 16539.92 2067.49 |
| 422 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm precast R.C.C. horizontal grating with frame complete as per standard design: i With common burnt clay F.P.S. bricks(non modular) of class designation 7.5 19.27.1 50.0 Each 5957.9 5899.9 6843.9 5799.93 289996.5 5799.93 |
| 423 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with precast R.C.C. vertical grating complete as per standard design: With common burnt clay F.P.S. bricks(non modular) of class designation 7.5 19.28.1 40.0 Each 6889.8 6822.8 7914.4 6707.12 268284.8 6707.12 |
| 424 | Constructing soak pit 2.5m diameter 3.0 metre deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100mmdiameter 1.8 m long complete as per standard design. i With common burnt clay F.P.S. bricks(non modular) of class designation 7.5 19.32.1 1.0 Each 26861.9 26600.5 30856.6 26149.68 26149.68 26149.68 |
| 425 | Boring/drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS:2800 (part-1) including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer-in-charge, upto 90 metre depth below ground level. i All types of soil 23.1.1.2 0.0 ii 350mm dia 23.1.1.2 300.0 Metre 774.05 766.5 889.1 753.53 226059.0 753.53 |
| 426 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS : 12818, including hire & labour charges, fittings & accessories etc, all complete, for all depths, as per direction of engineer-in-charge. i 200mm nominal dia 23.4.3 300.0 Metre 1255.7 1243.5 1442.5 1222.41 366723.0 1222.41 |
| 427 | Supplying & filling, sepreading & leveling stone boulders of size range 5cm to 20cm, in the recharge pit, in the required thickness, for all leads & lifts, all complete, for all depths, as per direction of engineer-in-charge. |
| 428 | Supplying & filling, sepreading & leveling gravels of size range 5mm to 10mm, in the recharge pit, over the existing layer of boulders, in the required thickness, for all leads & lifts, all complete, as per direction of engineer-in-charge. |
| 429 | Supplying & filling, sepreading & leveling coarse sand of size range 1.5mm to 20mm, in the recharge pit, in the required thickness over gravel layer, for all leads & lifts, all complete, as per direction of engineer-in-charge. |
| 430 | Providing and fixing Bail plug / Bottom plub of required dia to the bottom of pipe assembly of tubewell as per IS : 2800 (part -1) i 200mm dia 23.15.3 8.0 Each 357.6 354.1 410.8 348.12 2784.96 348.12 |
| 431 | Providing & fixing CI bar screen(painted) size 600x600mm with 8mm gap between the CI bars. |
| 432 | Providing fixing, jointing and testing in position the following UPVC pipes (working pressure 6kg/sqcm) conforming to IS: 4985 for drainage cut to required lengths including all necessary fittings and specials such as bends, junctions, offsets, making proper connections. Including providing PCC thrust block at 2 mtr. centre to centre. Pipe to be laid below ground level in trenches upto required depth including excavation in all kind of soil, dewatering, refilling, watering, ramming & removing the surplus excavated material and making good the same complete as required.For external sewer. i 110mm outer dia a) 50.0 Metre 1500.0 1271.19 63559.5 1271.19 ii 160mm outer dia b) 100.0 Metre 2000.0 1694.92 169492.0 1694.92 iii 200mm outer dia c) 50.0 Metre 2600.0 2203.39 110169.5 2203.39 iv 250mm outer dia d) 500.0 Metre 2750.0 2330.51 1165255.0 2330.51 |
| 433 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design i 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.13.1 0.0 With common burnt clay F.P.S. (non modular) bricks of class designation 7. 19.13.1.1 1.0 Each 52969.1 52453.7 60846.3 51564.66 51564.66 51564.66 (PIPING & VALVES) 0.0 |
| 434 | Providing, laying, testing and commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/3529 i/c fittings like elbows, tee, flanges tapers, nuts bolts, gaskets etc. in ground including welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes. complete as required. i 150mm dia 27.6.2 400.0 RM 5104.0 4325.42 1730168.0 4325.42 |
| 435 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : i 25 mm dia. 27.7.1 2480.0 RM 920.0 779.66 1933556.8 779.66 ii 32 mm dia. 27.7.2 480.0 RM 1039.0 880.51 422644.8 880.51 iii 40mm dia 27.7.3 340.0 RM 1259.0 1066.95 362763.0 1066.95 iv 50 mm dia. 27.7.4 250.0 RM 1557.0 1319.49 329872.5 1319.49 v 65 mm dia. 27.7.4 150.0 RM 1955.0 1656.78 248517.0 1656.78 vi 80mm dia 27.7.6 350.0 RM 2277.0 1929.66 675381.0 1929.66 vii 100mm dia 27.7.7 110.0 RM 3077.0 2607.63 286839.3 2607.63 viii 150mm dia 27.7.8 300.0 RM 4299.0 3643.22 1092966.0 3643.22 ix 200 mm dia ( wall thickness 6.3mm) 27.7.9 15.0 RM 6620.0 5610.17 84152.55 5610.17 x 250 mm dia ( wall thickness 6.3mm) 27.7.10 15.0 RM 8023.0 6799.15 101987.25 6799.15 |
| 436 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : i 65 mm dia 27.14.3 1.0 Nos 6913.0 5858.47 5858.47 5858.47 ii 100 mm dia 27.14.5 1.0 Nos 11853.0 10044.92 10044.92 10044.92 iii 150 mm dia 27.14.7 4.0 Nos 18884.0 16003.39 64013.56 16003.39 |
| 437 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : i 50 mm dia. 27.11.2 8.0 Nos 4114.0 3486.44 27891.52 3486.44 ii 65 mm dia. 27.11.3 2.0 Nos 4712.0 3993.22 7986.44 3993.22 iii 80 mm dia. 27.11.4 8.0 Nos 5406.0 4581.36 36650.88 4581.36 iv 100 mm dia. 27.11.5 16.0 Nos 7271.0 6161.86 98589.76 6161.86 v 150 mm dia. 27.11.6 18.0 Nos 9737.0 8251.69 148530.42 8251.69 vi 200 mm dia. 27.11.7 2.0 Nos 16248.0 13769.49 27538.98 13769.49 vii 250 mm dia. 27.11.8 2.0 Nos 21721.0 18407.63 36815.26 18407.63 |
| 438 | Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required. |
| 439 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. i 80mm dia 27.15.1 1.0 Each 5117.0 4336.44 4336.44 4336.44 ii 150mm dia 27.15.3 3.0 Each 11682.0 9900.0 29700.0 9900.0 |
| 440 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (FIRE HYDRANT ACCESSORIES) 0.0 |
| 441 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 27.9.1 25.0 set 8208.0 6955.93 173898.25 6955.93 |
| 442 | Supplying and fixing single headed external yard hydrant valve with 1 nos 63mm dia instantaneous FM Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 ( Type-A) with blank Gunmetal/Stainless steel Cap and chain as required: Single headed Gunmetal 27. 10.1 8.0 Set 8208.0 6955.93 55647.44 6955.93 |
| 443 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30m 27.17.1 25.0 Nos 9440.0 8000.0 200000.0 8000.0 |
| 444 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal 27.16.1 66.0 Set 5455.0 4622.88 305110.08 4622.88 |
| 445 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun Metal 27.18.1 33.0 Nos 4977.0 4217.8 139187.4 4217.8 |
| 446 | Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with \\" fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 2100x 900 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.) |
| 447 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 4 way-150mm dia M.S pipe 27.19.2 3.0 Each 14820.0 12559.32 37677.96 12559.32 |
| 448 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air relase valve on top and flange connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required: |
| 449 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: i Pendent Sprinkler 27.21.1 1200.0 Each 599.0 507.63 609156.0 507.63 ii Upright Sprinkler 27.21.2 50.0 Each 599.0 507.63 25381.5 507.63 iii Horizontal side wall Sprinkler 27.21.3 30.0 Each 699.0 592.37 17771.1 592.37 |
| 450 | Providing, fixing, testing and commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hyraulically driven mechanical gong bell sound continuous alarm when the wet riser/sprinkler system activates, pressure gauge, emergency release, strainer, pressur switch, cock valve complete with drain valve and bypass, test control box, ball valve, MS pipe of required size, flange, orifice plate,gasket etc of following size as required: i 150mm dia 27.24.3 2.0 Set 50805.0 43055.08 86110.16 43055.08 |
| 451 | Supplying, installation, testing and commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (inlet) 25mm NPT male thread to sprinkler head (outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following size complete as required. i 1000mm 27.25.2 600.0 Set 1703.0 1443.22 865932.0 1443.22 ii 1500mm 27.25.4 600.0 Set 1969.0 1668.64 1001184.0 1668.64 |
| 452 | Providing, installation, teasting and commissioning of adjustable rosette plate for 15mm dia in white finish UL listed or FM approved complete as required. (FIRE EXTINGUISHERS & MISC. ITEMS) 0.0 |
| 453 | Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.) |
| 454 | Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plug Capacity 6 liters.(IS:15683) 20.0 Nos 3955.66 3352.25 67045.0 3352.25 |
| 455 | Providing and fixing ISI Marked of approved make Fire Extinguishers complete with all accessories as per manufacturer's specifications. ABC dry powder stored pressure type 4.5 kg capacity (IS:15683). 80.0 Nos 5373.72 4554.0 364320.0 4554.0 |
| 456 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type,fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable door, dust and vermin proof, powder coated of approved shade after 7 tank treatment process,cable alley ,interconnection with suitable size copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V,3 phase,50Hz Ac supply with enclosure protection class IP 42 as required: 400A, 50KA 4pole MCCB, Ics= 100% Icu rating Digital Voltmetre 0-500V with selector switch Digital Ammeter (0-400 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps 0.0 Set of copper Bus Bar 500A 0.0 OUTGOING 0.0 Note : Outing feeder for pump should have digital ammeter with selector switchs, and LED type ON, OFF< trip indicating lamps) 0.0 DOWN COMER PUMP 0.0 63 A, 50kA TPN MCCB, Icu=100% Icu, with suitable HP fully automatic Star/Delta starter with overload proction, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 1.0 Set 223127.1 189090.76 189090.76 189090.76 |
| 457 | Providing, fixing, testing and commissioning of pressure vessel (minimum 450 mm dia & 1800 mm height) for pressurization of hydrant system complete with pressure gauge, valves at outlet / drain to operate as per operating sequences including 50 mm dia drain valve, air release valve with stop cock on the top Duly painted from inside and outside complete as required. |
| 458 | Providing and fixing standard firemans axe with heavy rubber handle. |
| 459 | Providing & fixing double flanged rubber expansion joint with unit control of standard length as per maufacturers specs. Tested to a pressure of 15Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required. i a) 65 mm dia 1.0 Nos 9447.09 8006.01 8006.01 8006.01 ii b) 150 mm dia 3.0 Nos 14725.82 12479.51 37438.53 12479.51 |
| 460 | Providing and fixing weather proof cabinet of size not less than 0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.) suitably marked on the outside 'with the letters \\"FIRE HOSE\\" including necessary locking arrangement and painting in red colour suitable to accomodate, external yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It shall be mounted on boundary wall complete as required. |
| 461 | Providing & fixing cast iron foot valve complete with flange.-100mm dia. (FIRE PUMPS & ACCESSORIES) 0.0 |
| 462 | Supply (installation, testing and commissioning) of electrically driven Main Fire Pump suitable for automatic operation consisting of the following, completein all respects,as required: Horizontally type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 0.0 Suitable HP squirrel cage induction motor, TEFC, synchronous speed 1500Rpm, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 0.0 M.S fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 0.0 Suitable cement concrete foundation duly plasterd with anti vibration pads. 0.0 Note: *The head of the pump is selected in a manner soa as to give a minimum 3.5kgf/cm² pressure at the higest/farthest point. 0.0 i 2850 lpm at 70 m Head 27.1.2 1.0 Set 425556.0 360640.68 360640.68 360640.68 |
| 463 | Supply, installation, testing and commissioning of Diesel Engine driven fire pump suitable for automatic operation consisting of the following, complete in all respects, as required:( Diesel Driven Pump) Horizontal type,multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 0.0 DESCRIPTION 0.0 Suitable HP, 1500 RPM water cooled with radiato, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, deisel tank, exhaust pipe extendend upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0 mm thick aluminimum sheet cladding, residential silencer, instruments and protections as per standard specification, stop solenoid for auto stop in the event of fault with audio indication, painted with post office red coclour etc. as required. 0.0 M.S fabricated, common based plated, coupling, coupling guard, foundation bolts etc as required. 0.0 Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.0 i 2850 lpm at 70 m Head 27.2.2 1.0 Set 647234.0 548503.39 548503.39 548503.39 |
| 464 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Jockey Pump). Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520. 0.0 Suitable HP squirell cage induction motor TEFC type suitabe for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure horizontal foot mountaed type Class-'F' insulation,conforming to IS:325. 0.0 M.S fabricated common based plated , coupling, coupling guard, foundation bolts etc.as required. 0.0 Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.0 i 180 lpm at 70m Head 27.3.2 1.0 Set 109254.0 92588.14 92588.14 92588.14 CONTROL PANEL 27.5 0.0 |
| 465 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type,fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable door, dust and vermin proof, powder coated of approved shade after 7 tank treatment process,cable alley ,interconnection with suitable size copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V,3 phase,50Hz Ac supply with enclosure protection class IP 42 as required: INCOMING 0.0 630A, 50KA 4pole MCCB, Ics= 100% Icu rating Digital Voltmetre 0-500V with selector switch Digital Ammeter (0-400 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps 27.5.3 0.0 Set of copper Bus Bar 800A 0.0 OUTGOING 0.0 Note : All outing feeders for pumps should have digital ammeter with selector switchs, and LED type ON, OFF< trip indicating lamps) 0.0 MAIN FIRE PUMP 0.0 250 A, 50kA TPN MCCB, Icu=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload proction, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation 0.0 JOCKEY PUMP 0.0 125 A, 50kA TPN MCCB, Icu=100% Icu, with suitable HP fully automatic Star/Delta starter with overload proction, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 0.0 DIESEL ENGINE CONTROL 0.0 Control for diesel engine comprising - 0.0 Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode. 0.0 Indicating lamps for high/low lub. Oil pressure, high high water temp and engine on indication. 0.0 Battery charge suitable for 12V/24V DC with boost and trickle selector switch,0-30V DC volt meter, and 0-20A dc Ammeter. 0.0 All standard relays and accessories for automatic operation of deisel engine. 0.0 SYSTEM CONTROLLER 0.0 Designing, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, terrace pump in sequence as per specification consisting of relays, timers, sensors, annuniciation window for fault indication, complete as per specification. 1.0 Set 337486.0 286005.08 286005.08 286005.08 |
| 466 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 0.0 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 0.0 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. 0.0 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 0.0 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.0 900 lpm at 35 m Head 27.4.1 1.0 Set 107744.0 91308.47 91308.47 91308.47 HVAC WORKS 0.0 MACHINERY 0.0 |
| 467 | Variable Refrigerant Volume System Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 0C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity 40 and 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both 0.0 Outdoor VRV Unit 0.0 i 8 HP capacity 31.1.1 8.0 HP 20947.0 17751.69 142013.52 17751.69 ii 22 HP capacity 31.1.3 22.0 HP 19111.0 16195.76 356306.72 16195.76 INDOOR UNIT HIWALL TYPE 31.8 0.0 |
| 468 | Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) i 2.0 TR 31.8.6 11.0 each 22674.0 19215.25 211367.75 19215.25 |
| 469 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs i Indoor Units 31.13.1 10.0 set 4535.0 3843.22 38432.2 3843.22 PLUMBING 0.0 PIPING & INSULATION 0.0 Copper Refrigerant Piping 31.14 0.0 |
| 470 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : i 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mmthick insulation 31.14.1 35.0 m 256.0 216.95 7593.25 216.95 ii 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mmthick insulation 31.14.2 25.0 m 346.0 293.22 7330.5 293.22 iii 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13mm thick insulation 31.14.3 20.0 m 487.0 412.71 8254.2 412.71 iv 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13mm thick insulation 31.14.4 25.0 m 615.0 521.19 13029.75 521.19 v 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 13 mmthick insulation 31.14.5 25.0 m 739.0 626.27 15656.75 626.27 vi 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 31.14.6 35.0 m 904.0 766.1 26813.5 766.1 vii 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation 31.14.8 22.0 m 1157.0 980.51 21571.22 980.51 NOTE:- (1) The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by :(i) Using One End Expanded Tubes (ii) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum.(3) The makes of tube fittings shall be same as that of tubes.(4) The thickness of fittings used shall be same as that of the pipe. 0.0 PVC Drain Piping MR 0.0 |
| 471 | Supply, Installation, testing and commissioning of PVC piping complete with fittings, supports accessories in surface/recess as per specifications & site requirments including with duly insulated with 6 mm thick sleeve of nitrle rubber having K value 0.033 W/MK at 10 deg. C mean temp. and minimum density of 25 Kg/Cum. Insulation on drain pipe i 25 mm Dia MR 25.0 m 169.0 143.22 3580.5 143.22 ii 32 mm dia MR 15.0 m 217.0 183.9 2758.5 183.9 ELECTRIC WORKS 0.0 ELECTRICAL PANEL MR 0.0 |
| 472 | Design, manufacture, supply, installation and commissioning of the following extensible cubicle type indoor mounting Powder coated, modular compartmentalized IP 42, dead front, dust and vermin proof, floor mounting 2 mm thick sheet steel clad switchboard suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of 35kA at 415 volts. NOTE: The following provisions shall be required to be made in the switchboard detailed below 0.0 The Switchboard shall have provision for entry of all XLPE cables from the top/bottom as required. 0.0 All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. 0.0 Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required 0.0 Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, TIMER, control wiring, Auxiliary contactors MCB’s as required at site 0.0 All fault level breaking capacity indicates shall be I.C.S value at 415 volts. (ICS = ICU =ICW=100%) for 1 sec 0.0 All MCCB above 100 Amp shall have variable overload settings. 0.0 All MCCB shall have with Rotary Handles. 0.0 Space heater/light/air filter shall be provided for each vertical compartment. 0.0 Padlocking facility shall be provided on all outgoing feeders. 0.0 All ACB’s shall have all standard accessories such as CT,s Arc Chute, safety shutters etc. 0.0 Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB rating at same amount of current density as of main busbar. 0.0 2 No GI strip throughout the panel. 0.0 All incoming as well as outgoing circuit breaker shall be compatible with BAS system. 0.0 HVAC OUTDOOR PANEL 0.0 HVAC PANEL 0.0 Electrical Panel for VRV Outdoor Units MR 0.0 Supplying, installation testing and commissioning of cubical type main MV panel board suitable for 3 phase, 415 + 10% volts, 50 + 3% Hz and of 25 KA rupturing capacity at 415 volts, fabricated from minimum 2 mm thick and doors of 1.6 mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with mountings, interconnections, earthing etc including mechanical and Electrical Inter locking as required. 0.0 Incoming 0.0 1 No. 63 Amps 415 volt 25 kA TPN MCCB with microprocessor release having overcurrent and short circuit protection and CBCT & ELR complete with rotary operating mechanism with spreader. 0.0 Metering 0.0 i. Red/Green/Amber/ ON/OFF trip indicating lamps with MCB,s protection-1set. 0.0 ii. Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 63/5 amps 10 VA CT's to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set 0.0 Bus-bar 0.0 Main bus bar rated at 100 amps 4 pole,25 KA with heat shrinkable sleeve and shall be of aluminium. 0.0 Outgoings 0.0 3 Nos. 63 amps TPN MCCB with outgoing feeder to VRV outdoor unit.The compartment shall contain an indicating lamp with MCB for ‘ON’ status of compressor motor. MR 1.0 Set 102677.0 87014.41 87014.41 87014.41 |
| 473 | Weather Proof isolators for Outdoor Units Supplying, installation testing and commissioning of 415 volt three phase and neutral swith outlets TPN MCCB/MCB iasolator in weather proof IP 65 enclosure. The quantities of isolators is as follows. 0.0 i 63 amps TPN MCB in weather proof enclosure for VRV outdoor units. MR 2.0 Set 6644.0 5630.51 11261.02 5630.51 Power Cabling MR 0.0 |
| 474 | Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles & fixing bolts/including testing & commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap & shall be properly clamped with cable clamps & ties. Identification tags shall be provided for all cables including cable end termination. i 4 core 16 Sq mm MR 115.0 Rmt 297.0 251.69 28944.35 251.69 |
| 475 | CONTROL CABLING Supply, laying, testing and commissioning of control cabling, as per Standard specification including end termination as required. 0.0 Power Cabling ( PVC insulated and PVC sheathed, armoured, Copper Conductor of 1.1 KV grade on existing cable trays). 0.0 i 2C x 1.5 Sq mm MR 115.0 Rmt 157.0 133.05 15300.75 133.05 ii 2C x 2.5 Sq mm MR 85.0 Rmt 186.0 157.63 13398.55 157.63 Electrical Cable Tray 4.1 0.0 |
| 476 | Supply and installation of following size of perforated painted with powder coating G.I. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including bolts & nuts, painting suspenders etc as required. i 100 mm width X 50 mm depth X 1.6 mm thickness 4.1.1 25.0 RM 623.0 527.97 13199.25 527.97 ii 150 mm width X 50 mm depth X 1.6 mm thickness 4.1.2 30.0 RM 686.0 581.36 17440.8 581.36 iii 200 mm width X 50 mm depth X 1.6 mm thickness 4.1.3 25.0 RM 775.0 656.78 16419.5 656.78 iv 300 mm width X 50 mm depth X 1.6 mm thickness 4.1.4 15.0 RM 866.0 733.9 11008.5 733.9 Earthing 5.7 0.0 |
| 477 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. TOTAL AMOUNT 341067750.54 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender