Tender For Augmentation Of Ht Electric Supply To Feeder No. 1 And No. 3 With Allied Works At Fatehgarh Cantt
Tender Value
1.44 Crore
Estimated cost
Bid Submission
05 Dec 2026
26 days left
EMD
2.19 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Farrukhabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Augmentation Of Ht Electric Supply To Feeder No. 1 And No. 3 With Allied Works At Fatehgarh Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of 12 KV, 630 Amp, 21 kA for 3 seconds, 7-way, extensible, outdoor all 7 ways, floor-mounted, SF6 gas insulated, motorized Ring Main Unit (RMU), AEGIS+ type, M+LLVVV+VV+ configuration, comprising of 2 Nos Load Break Switches (LBS)/Isolators and 5 Nos Vacuum Circuit Breakers (VCBs/CBs), with suitable protection relays and CTs as per the existing load, complete with internal copper busbars, IP54-rated outdoor enclosure, floor-mounted construction, motorized operating mechanisms, protection and control equipment, electrical and mechanical interlocks, auxiliary contacts, internal wiring and cabling, terminal blocks, earthing provisions, indication and metering facilities, mechanical and electrical accessories, and all necessary hardware, consumables and accessories required for complete installation and commissioning. The RMU shall be suitable for 12 KV, 3 Phase, 50 Hz system, rated 630 Amp, with short-time withstand capability of 21 kA for 3 seconds, and shall comply with the latest applicable requirements of IEC 62271-1, IEC 62271-100, IEC 62271-102, IEC 62271-103, IEC 62271-200, IEC 60529 and other relevant IEC standards. The RMU shall be complete with all accessories as detailed in Annexure-A to the BOQ.Description of item Contd.... Please Enable Macros to View BoQ information |
| 2 | Supply, installation, testing and commissioning of 12 KV, 630 Amp, 21 kA for 3 seconds, 7-way, extensible, outdoor all 7 ways, floor-mounted, SF6 gas insulated, motorized Ring Main Unit (RMU), AEGIS+ type, M+LLVVV+VV+ configuration, comprising of 2 Nos Load Break Switches (LBS)/Isolators and 5 Nos Vacuum Circuit Breakers (VCBs/CBs), with suitable protection relays and CTs as per the existing load, complete with internal copper busbars, IP54-rated outdoor enclosure, floor-mounted construction, motorized operating mechanisms, protection and control equipment, electrical and mechanical interlocks, auxiliary contacts, internal wiring and cabling, terminal blocks, earthing provisions, indication and metering facilities, mechanical and electrical accessories, and all necessary hardware, consumables and accessories required for complete installation and commissioning. The RMU shall be suitable for 12 KV, 3 Phase, 50 Hz system, rated 630 Amp, with short-time withstand capability of 21 kA for 3 seconds, and shall comply with the latest applicable requirements of IEC 62271-1, IEC 62271-100, IEC 62271-102, IEC 62271-103, IEC 62271-200, IEC 60529 and other relevant IEC standards. The RMU shall be complete with all accessories as detailed in Annexure-A to the BOQ.Description of item Contd.... Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedDec 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysDec 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender