Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #58445552

Tender For Comprehensive Maintenance Of Dg Sets, Amf Panels, Apfc Panels, Water Flow Meters, Pressure Filter And Misc Works Bairagarh Military Station Under Ge Bhopal

Issued by Statutory Bodies & Commissions/Committees · Bhopal, Madhya Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
9 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Of Dg Sets, Amf Panels, Apfc Panels, Water Flow Meters, Pressure Filter And Misc Works Bairagarh Military Station Under Ge Bhopal

BOQ

Name of Work:- COMPREHENSIVE MAINT OF DG SETS, AMF PANELS, APFC PANELS, WATER FLOW METERS, PRESSURE FILTER AND MISC WORKS BAIRAGARH MILITARY STATION UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline
2Comprehensive maintenance of 320 KVA DG sets consisting of normal repairs with periodical routine maintenance, attending breakdown as and when required and testing of DG set complete i.e. Engine, Alternator etc including all consumables items like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out all as directed by Engineer-in-Charge, and comprising of the following :-(a) Change/top up engine oil. (b) Replacement of Oil Filter element, Fuel filter element, air filter element, fuel flexible pipe, V belt for water pump and alternator, cleaning of Fuel tank etc.(d) Adjusting valve tappet/governor clearance/timing(e) Injector pressure test cleaning and repairing, tightening fasteners and making lubrication leak proofNote:- (i) Engine oil will be paid separately. (ii) Labour charges for dismantling / taking down and replacement/refixing new parts as and when required is deemed to be included in unit rate quoted.(iii) Spares(as per sample) and lubricant to be measured and paid separately under respective items here-in-after. NOTE 4:All spare parts should be approved by Engr-in-Charge before fixing. 320 KVA DG Set Make: Cummins by carrying out routine 'B' check of the engine for smooth functioning complete all as per manufacturer's instructions and as directed.
3All as per item No 1.00 here-in-before but for 15/ 20/ 50 KVA to 62.5 KVA capacity of Make: Kirloskar
4All as per item No 1.00 here-in-before but for 750 KVA capacity of Make: Kirloskar
5Supply only fuel filter set (pre and secondary) including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
6Supply only fuel filter set (pre and secondary) including rubber gasket for DG sets of capacity 750 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
7Supply only fuel filter set (pre and secondary) including rubber gasket for DG sets of capacity 15/ 20/ 40/50 KVA to 62.5 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
8Supply only fuel filter (pre and secondary) including rubber gasket for DG sets of capacity upto 20 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
9Supply only fuel filter (pre and secondary) including rubber gasket for DG sets of capacity upto 15 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
10Supply only air filter element including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
11Supply only air filter element including rubber gasket for DG sets of capacity 750 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
12Supply only air filter element including rubber gasket for DG sets of capacity 15/ 20/ 40/50 KVA to 62.5 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
13Supply only lube oil filter including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
14Supply only lube oil filter including rubber gasket for DG sets of capacity 750 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
15Supply only lube oil filter including rubber gasket for DG sets of capacity 15/ 20/ 40/50 KVA to 62.5 KVA complete all as specified and directed. Make of the filters shall be as per OEM recommendations
16Supply only fan belt of existing size for DG sets of capacity 320 KVA complete all as specified and directed. Make of the belt shall be as per OEM recommendations
17Supply only fan belt of existing size for DG sets of capacity 750 KVA complete all as specified and directed. Make of the belt shall be as per OEM recommendations
18Supply only fan belt of existing size for DG sets of capacity 15/ 20/ 40/50 KVA to 62.5 KVA complete all as specified and directed. Make of the belt shall be as per OEM recommendations
19Supply & fix in replacement Hose Rubber pipe set for radiator of capacity 15/ 20/ 40/50 KVA to 62.5 KVA as per OEM recommended complete all as specified and directed.
20Supply & fix in replacement Hose Rubber pipe radiator of capacity 320 KVA as per OEM recommended complete all as specified and directed.
21Supply & fix in replacement Hose Rubber pipe radiator of capacity 750 KVA as per OEM recommended complete all as specified and directed.
22Supply & fix in replacement Hose rubber pipe for fuel of capacity 15/ 20/ 40/50 KVA to 62.5 KVA as per OEM recommended complete all as specified and directed.
23Supply & fix in replacement Hose Rubber pipe for fuel of capacity 320 KVA as per OEM recommended complete all as specified and directed.
24Supply & fix in replacement Hose Rubber pipe for fuel of capacity 750 KVA as per OEM recommended complete all as specified and directed.
25M&L for dismantling of radiator assembly of 320 KVA from generating set and transportation to the workshop(if required) , repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and radiator pump incl repair of defective copper winding/coils and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.
26M&L for dismantling of radiator assembly of 750 KVA from generating set and transportation to the workshop(if required) , repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and radiator pump incl repair of defective copper winding/coils and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.
27M&L for dismantling of radiator assembly of 15KVA/20 KVA /30 KVA/50 KVA from generating set and transportation to the workshop(if required) , repair the tank /storage portion incl necessary welding/soldering & making leak proof of the tank, cleaning the complete radiator with chemical agent and pumping set incl replacement of defective copper core and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.
28S&F in repair of radiator pump of capacity 15KVA/20 KVA /30 KVA/ 50 KVA & 320 KVA DG installed at DG sets at different locations including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.
29S&F in repair of radiator fan of capacity 15KVA/20 KVA /30 KVA/ 50 KVA/ 320 KVA &750KVA DG installed at DG sets at different locations including replacement of all old rusted MS nuts, bolts washers & gasket sets including refixing and testing complete all as specified and directed.
30Supply and filling of Engine oil 15W40 to top up/ replacement of all DG set of various capacity, model & location as mentioned here-in-before as per the standard practice complete all as specified and directed.(Make: SERVO / Castrol / HP / Valvoline).
31Supply and filling of Coolant suitable for DG set of various capacity, model & location as mentioned here-in-before as per the standard practice complete all as specified and directed.
32M&L for finding out defects of control panel /Power Panel/AMF Panel /Engine /Alternator/AVR of DG set of capacity 15KVA/20 KVA /30 KVA/ 50 KVA/320 KVA & 750KVADG set and taking out burnt interconnection wiring including u/s and serviceable components for reuse including Rewiring of damaged portion of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes including refixing serviceable items and testing complete all as specified and directed by Engr- in- charge. Note:- (i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) The contractor has to rectify the breakdown of the DG set and make the DG set functional within 24 hours after intimation to the contractor through any mode by the concerned JE E/M or AGE E&M. In case the complaint is not made rectified for whatsoever reason within the specified time limit, an amount of Rs 1000/- per such breakdown per day will be recovered from the amount due to him through RAR / Final Bill.(iii) Contractor will inspect all DG sets within 15 Days after accepting the Contract and also submit the schedule of maintenance required for DG set keep functional during the entire contract period. (iv) The contractor shall maintain sufficient stock of spares / material required for repair / maint of DG set.
33Dismantling the fuel pump from the engine of DG set of capacity 320 KVA, transporting to the service center for complete servicing and overhauling of the pump with and including M&L for replacement of service kit, element, delivery valve, plunger, copper washer etc. as required and re-calibration, refixing and testing complete all as specified and directed.
34Dismantling the fuel pump from the engine of DG set of capacity 750 KVA, transporting to the service center for complete servicing and overhauling of the pump with and including M&L for replacement of service kit, element, delivery valve, plunger, copper washer etc. as required and re-calibration, refixing and testing complete all as specified and directed.
35Dismantling the fuel pump from the engine of DG set of capacity 15KVA/20 KVA/30 KVA/40KVA / 50 KVA /62.5KVA transporting to the service center for complete servicing and overhauling of the pump with and including M&L for replacement of service kit, element, delivery valve, plunger, copper washer etc. as required and re-calibration, refixing and testing complete all as specified and directed.
36S&F in replacement new water pump of existing size suitable for DG Set of capacity 320 KVA and testing complete all as specified and directed.
37S&F in replacement new water pump of existing size suitable for DG Set of capacity750 KVA and testing complete all as specified and directed.
38S&F in replacement new water pump of existing size suitable for DG Set of capacity 15KVA/20 KVA/30 KVA/40KVA / 50 KVA /62.5KVA and testing complete all as specified and directed.
39Draining out the diesel tank and cleaning/ washing out the sludge and re-filling with retrieved diesel in the tank for DG set of capacity 15KVA/20 KVA/30 KVA/40KVA / 50 KVA /62.5KVA750KVA complete all as specified and directed.
40S&F in replacement of fuel pump of existing size suitable for DG Set of capacity 320 KVA to transfer fuel from tank to FIP and testing complete all as specified and directed.
41S&F in replacement of fuel pump of existing size suitable for DG Set of capacity 750 KVA to transfer fuel from tank to FIP and testing complete all as specified and directed.
42S&F in replacement of fuel AC pump of existing size suitable for DG Set of capacity 5KVA/20 KVA/30 KVA/40KVA / 50 KVA /62.5KVA to transfer fuel from tank to FIP and testing complete all as specified and directed.
43Disconnecting the self starter(12V/24V) from the engine body, dismantling the same, checking for identification of faulty spares and reassembling the same after complete servicing and overhauling and replacement of faulty spares, if required, including refixing to its original position (for 15KVA/20 KVA/30KVA/50 KVA/320KVA/750KVA DG),complete all as per specified and directed by Engr in charge. (Note :Spare required to be replaced i.e. clutch assembly, Bendex pinion, Solenoid switch , Carbon Brush, Armature Field Coil , Self armature coil included in the item rate).
44S&F in repair battery, 12 Volt, 180 AH suitable to existing 320 KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
45S&F in repair battery, 12 Volt, 180 AH suitable to existing 750 KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
46S&F in repair battery, 12 Volt, 150 AH suitable to existing 50 KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
47S&F in repair battery, 12 Volt, 100AH suitable to existing 62.5KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
48S&F in repair battery, 12 Volt, 150 AH suitable to existing 40 KVA/15KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
49S&F in repair battery, 12 Volt, 100AH suitable to existing 30 KVA/20KVA DG Set complete all as per specified and directed. (Make : Exide /Amaron/TATA Greens or equivalent)
50S&F in replacement of Fuel Tank Cap with Lock for DG set of any capacity complete all as specified and directed.
51S&F in replacement of Battery terminal leads complete with brass connector complete all as specified and directed.
52Supply and pouring distilled water/acid mixture for battery complete all as specified and directed by Engr in charge.
53S&F in repair Automatic Battery Charger,input-230 Volt, AC, output - 12 Volt DC, 10 Amps. having electric circuit consisting of triodes rectifiers, capacitors and resistance etc. complete including connection with 2.5 Sqmm 3 core PVC insulted copper cable and three Pin Top. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger though control panel or electric power point complete all as per specified and directed. (Make : Luminous/ Bajaj or equivalent make as approved GE)
54M&L For door lock assembly with keys suitable for acoustic enclosure for DG Sets of any capacity including all accessories complete all as specified and directed by Engr in charge.
55M&L for repairing of DG Set Canoy doors of any sizes including necessary hinges, welding work, as per site requirement complete all as directed by EIC.
56S & F Pre- painted galvalume aluminum zinc coating (AZ 150) GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws for scada valve as rain protection sheet complete all as specified and directed.
57M&L for mild steel framed work for made of angle iron with / mild steel sheet (for making/repairing the external fuel tank of any capapicity) /MS Square pipe as required including necessary welding, cutting, hinges, locking arrangments, and its nut bolts etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
58M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping/supports and similar work including necessary form work for control panel etc including dismantling exiting one complete all as specified and directed.
59Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in hard dense soil and getting out complete all as specified and directed.
60Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 cm thick complete all as specified and directed.
61Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected.
62M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:- Compacted/punned thickness shall be measured & paid.
63S & fix in repalcement AVR suitable for 320 KVA Alternators as per OEM recommended complete all as specified and directed.
64S & fix in repalcement AVR suitable for 750 KVA Alternators as per OEM recommended complete all as specified and directed.
65S & fix in repalcement AVR suitable for 15KVA/20 KVA/30KVA/50 KVA/62.5KVA Alternators as per OEM recommended complete all as specified and directed.
66M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 10 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and as directed.Note: Necessary earthwork included in the item rate.
67Supply, Installation, Testing and Commissioning of 200 mm dia, Water Flow Meter, along with all necessary installation accessories like gate valve, barrel piece, double nipple, elbows/bends etc and cutting to existing MS pipe and fixing of new MS flanged with necessary welding with following specification complete all as specified and directed:-Accuracy: - ±2.0% of reading Flow velocity range, m/s: - 0.02 - 5 Output: - Two way isolated pulse output (pulse equivalent and output pulse can be arbitrary programmed); two-wired system 4-20mA output. Maximum pipeline pressure, MPa / bar: - 25 Ambient temperature range, °С: - 5 - 65 Power Supply: - Lithium battery Protection: - IP 68Technical Specification: - Less than 0.01 m/s starting velocity, Multi line 9 digital LCD accumulative flow and 4 digitalfor instantaneous flow, Date cumulative record and data acquisition function, Various of Units selected, includingCubic meter, USA gallon, Cubic feet and Liter, With the two way PT1000 temperature transducer, which can realizethe heat measurement. Display parameters: - Flow Rate, Totalizer - Forward, Reverse, Net, No of hours meter was installed, worked.Archives have record of Daily reading for 31 days and monthly reading for 32 Months.Note -1). Supply, wiring & testing, commissioning, programming of Water Flow Meter shall be carried out by authorizedsystem integrator of the provided makes. The engineer shall submit a letter from the OEM as proof of his being anauthorized system integrator of the OEM. The engineer shall also submit a signed report on original letterhead ofthe OEM that programming, wiring & testing, commissioning has been carried out by him.Make of item - UNIVERSAL SWITCH GEAR CONTROL /EMERSON/KROHNE MARSHALL/ YOKOGAWA ELECTRICNote : The already installed SCADA Software & PLC Panel is installed and programmed by M/S UniversalSwitch Gear Control. It is Commanded that the updating of SCADA Software & PLC Panel should be done throughOEM(i.e. M/S Universal Switch Gear Control
68Supply & fix in replacement LT feeder pillar panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy power coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI tested manufacturer only. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars, electrolytic grade of adequate rating or as specified below. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators/ Meters etc. All joints and connection shall be done with galvanised or codmium plated high tensile nuts, bolts and washers. The Panel shall be provided with digital multifunction meter with cast Resign CTs & RYB LED indicating lamps at Incoming . The panel shall be provided with heavy duty ss cable glands of adequate size for incoming and all outgoing cables. The panel shall be provided with Busbar chamber and cable alley of suitable size. The single line circuit diagram showing the arrangements of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided with 04 Nos 50mmx50mmx6mm thick angle iron supports of not less than each 0.9 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement. All terminals shall be provided with spreader links with phase separators on both sided and suitable for incoming cables complete all as specified and as directed. The overall size of the panel shall not be less than 900mmx400mmx900mm (LxDxH). The panel shall be provided with and including following accessories :- Note : PCC and Earthwork shall be measured and paid sepeartelya) Aluminium bus bars 200 amps, 50KA rating suitable for 3 phase 4 wire system for connection of 6 Nos LT Cables for 120 Sqmm size 02 Nos, 95 Sqmm -02 Nos, 50 Sqmm - 02 Nosb) On load change over switch four pole with advance Neutral 200 amps current rating open execution conforming to IS 13947 (part-3) Make - L&T cat part No. CO22000OOOA /Havells/C&S Qty-01 Noc) Voltmeter -01 Nos , Ammeter-01 Nos Make - Legrand/L&T/Schneider including suitable size of CTs etc
69Disconnecting and taking out existing Serviceable/defective cables alongwith old size bricks etc of 6 core 1.5 sqmm and setting aside for further disposal as diected Note: Excavation & earthwork will be measured & paid & separately.
70Relaying of serviceable 6 core 1.5 Sqmm complete all as specified and directed.Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A
71Supply and laying Burnt clay fly ash building bricks designation 75(Kg/cm2), laid in right angle along the cable, complete all as specified.
72Supply, Installation, Testing and Commissioning of 6 Core XLPE 1.5 Sqmm steel wire armoured pvc sheathed Copper multistranded conductor for Communication of scada actuators etc complete all as speciifed and directedMake - Havells/Polycab/Finolex
73Supply & Fix in repair 125 Amps manual changeover 04 Pole in sheet metal enclosure of size Fr2 Conforms to IEC 60947-3, IS/IEC 60947-3) including spreader terminal Shrouds, Source Separator and Phase Barriers Suitable for horizontal as well as vertical mounting including fixing in wall and taking down existing one complete all as specified and directed.Make- L&T cat part No CO21250OSOO/Legrand/Havells/C&S
74Supply and fixing illuminated display board of size shall not less than 900mmx300mmx900mm (L x B xH) and 150mm depth with Flex of Light Blue( MES Colour) Colour of letters shall be white, outerside fabrication bordered with Aluminium angle Frame of size 35mm x 35mm x 4mm thick, inner side fabricated with 12mm MS square bar including all internal wirings and illuminated with 2 feet LED 20 W Tubelight fitting 02 Nos, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make sintex cat part No GSJB-1414 and written \\"RAW WATER PUMP HOUSE, 1 TB PUMP House, 21 CGSR PUMP House, MH PUMP House, MES Colony PUMP House, Engr Regt PUMP House, of AGE E/M BHOPAL, GE Bhopal\\", size of letters shall be proportion with overall size of board with electrical connection complete in all respect and electrical connection with PVC insulated 3 core multistranded copper conductor not less than 4 Running meter complete all as specified and as directed. Note : Before manufacturing boards drawing and design of Board including colour of board shall be approved by Engr-in-charge.
75Supply and fixing illuminated display board of size shall not less than 5.2M x .3M x .45M (L x B xH) with Flex of Light Blue( MES Colour)/ Colour of letters shall be white, outerside fabrication bordered with Aluminium angle Frame of size 35mm x 35mm x 4mm thick, innerside fabricated with 12mm MS square bar including all internal wirings and illuminated with LED 20 W Tubelight fitting 04 Nos, SMC/FRP Junction Box 140mm x 140mm x 95mm inner dimension make and written \\"WATER FILTERATION PLANT, AGE E/M BHOPAL, GE BHOPAL.\\" , size of letters shall be proportion with overall size of board including taking down existing one with electrical connection complete in all respect and reconnect electrical connection with new one complete all as specified and as directed. Note : (i)Before manufacturing boards drawing and design of Board including colour of board shall be approved by Engr-in-charge.(ii) It shall be fixed on MS square angles frame no less than 4M height from the ground level and its square pipes/Angle iron structure/PCC etc shall be meaured and paid seperately.
76Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down existing one complete all as specified and directed.
77M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 1.5 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 1.5 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE]Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 1.5 sqmm cable, one run of 1.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
78Supply, Installation, Testing and Commissioning of PLC (Programmable Logic Controller) based outdoor type and with IP 54 protection Monitoring / Annunciating Control Panel with inbuilt wireless DUAL SIM Card GPRS communication modem and suitable antenna (at RAW Water pump house) for Automatic operation of VT Pump and Valve Control / Protection suitable for 04 nos. VT Pumps (125 HP 02 Nos, 75 HP 02 Nos, 04nos. Motorized Valves (+01 Spare), 02 nos. Pressure Switches, and 01 Nos water flow meter (Water flow should be display in HMI and Scada system also. The panel shall not be less than size 1000mm(h) x 600mm(w) x 250mm(d) (as required for easy operation) fabricated from 2.0 mm thick CRCA sheet and properly powder coated. It shall be floor mounted on properly powder coated sheet metal stand of suitable size. The Panel should be capable of carrying out the below mentioned activities(a) Details of Flowmeter should be visible in HMI, Line diagram should be displayed on PLC Panel. (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention (h) Manual Mode OperationThe PLC based Panel shall consist of (i) 01 No. PLC with following specifications; (a) PLC should be suitable no. of Digital / Analog inputs / outputs(b) 2 serial ports supporting open communication protocol, (c) Programming software based on IEC to facilitate building of custom built function blocks Note : Make for PLC :- Siemens/ GE FANUC / Schneider Electric/ mitsubishi/ Rockwell Automation / ABB. (ii) 01 No. HMI - 7\\" (min) Graphical Touch screen multicolor having following minimum features (Make: Schneider Electric / Siemens /ABB) a. 02 nos. serial ports and 01 no. USB port , (b). Floating Point support (c) Built in RTC (d). Bar Graph and image (bmp, jpeg files) e. Real time and historical Trending, f. Real time and historical alarms iii) 01 No. SMPS of 5 A rating (Make: Schneider Electric / NHP or equivalent approved make) (iv) Suitable No. of interposing relays 24 V D.C. and 230 V A.C. coil rating and 6 A contact rating (Make: OEN / OMRON / IDEC / ALLEN BRADLEY) , (vi)2.0 KVA UPS / INVERTER with Sealed Maintenance free Batteries for powering the panel for a minimum of 06 hrs in case of supply failure. (Make: APC / TATA LIEBERT / NUMERIC / LUMINOUS ) (vii) Transformer of suitable rating (viii) MCB of suitable rating (Make: Havells/ Schneider Electric or equivalent approved make)
79Item No.59.00 is continued.............. (ix) Single Phase Preventer (Make: MINILEC or equivalent approved make ) (x) Illuminated Push Buttons, Push Buttons and Indicator Lamps as per requirement (Make: Schneider ElectricER / ESBEE or equivalent approved make) (xi) Selector Switches as per requirement (Make: Schneider ElectricR / ESBEE or equivalent approved make) (xii) Audio Visual Alarm Indicator (Make: MIMIC / ESBEE / Schneider Electric ). Make for PLC control panel : Recktronic Devices and system / CIMCON / SEEPL / Universal Switch Gear Control /SECO or any other equivalent of PLC based control panel make approved by E-in-C’s Branch. (xiii) 4G enabled wireless dual SIM card based communication module comprising of one Main and One standby Modem with suitable antenna and data enabled SIM cards - 02 nos.(01 no. per modem) using 02 different service providers. The module shall be programmed to automatically toggle between the two service providers based on the actual signal strength available.(Make of Modem: MOTOROLA / MAESTRO / ELPRO ). The quoted cost shall include the cost of communication for a period of 36 months from the date of completion.
80Updating & Upgradation of SCADA Software & PLC Logic as per the new installed field devices in existing PC basedmaster control station and PLC Panel.The scope includes:-Services for programming, configuration and customisation of the Smart Station Platform with respect to the Watersupply Module in SCADA Software & PLC Logic as per actual site conditions and requirement of the engineer. Line diagram of upgraded system alongwith all details of ActuatorsNote: - The contractor has to submit the MOU from OEM in the technical bid itself, failing of the same will lead torejection of bid in Technical Evaluation of Tender Bid. The successful bidder has to submit a Memorandum ofUnderstanding (MoU) from OEM (i.e. M/s Universal Switch Gear Control) in a non-judicial stamp paper of Rs 10.00duly notorised with an undertaking stating that execution of all SCADA related items of work shall be carried outunder technical support and guidance of OEM.
81Supply, Installation, Testing and Commissioning of 4 Core XLPE insulated 1.5 Sqmm armed Copper multistranded conductor Shielded cable for Communication of scada actuators etc complete all as speciifed and directed .
82Supply, Installation, Testing and Commissioning of 2 Core XLPE insulated 1.5 Sqmm armed Copper multistranded conductor Shielded cable for Communication of scada actuators etc complete all as speciifed and directed.
83M& L for Sand and lay for dry river sand filling in trenches for UG cable protection with a layer of 8cm deep before laying of cable and 15cm above the top edge of the cable of after laying of the cable complete all as specified and directed.
84M&L for cleaning and degermination inside of RCC/PVC water storage tanks capacity not exceeding 500 Ltr to 750 Ltr of any description and in any position comprising following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using Trebac G5/Inchlor-5/NB-10, Terbac G65/Inoxi-60/NB-69 and ultra violet rays complete all as specified and as directed.Note:-Contratcor will have to address tank cleaning complaint within 24 Hours if the Contractor fails to rectify the tank cleaning complaint contractor shall pay penalty charges are as under:(a) Upto 1st working day - Rs 100.00/Day/per tank(b) Above 1 working day and upto 02 Working day - Rs 200.00/Day/per tank(c) Above 02 Working day - Rs 300.00 /Day/per tank.(d) The tradesman (01 skilled Plumber and 02 helper alongwith wooden/Aluminium ladder not less than 32 Feet-01 Nos, not less than 20 feet -01 Nos, 12 feet -01 Nos and necessary T&P for GI pipe/PPR pipe/UPVC pipes etc) shall report to E/M complaint cell of AGE E/M Bairagarh Bhopal daily at 8.30 am to take complaints from concern JE E/M. The complaint slip duly signed by the users shall be returned back at the complaint cell after rectification of complaint. (e) Urgent tank cleaning complaint must be completed either in holiday or sunday.
85All as per Item No 64.00 here-in-before but 1000 Ltr capacity.
86M&L for servicing/repairing of APFC panel, any type and size upto 150 KVAR for making them functional, removing and cleaning of dust, checking control wiring and connections, replacement of any damaged control wire, checking capacitors, tightening of all electrical connections and hardware, checking of metering devices, relays, etc, replacement of defective unserviceable parts to make the panel fuly functional complete all as specified and all as directed by Engineer-in-charge. Note :- Spares required shall be paid separately as supply only.
87Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 15 KVAR complete all as specified and directed.
88Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 10 KVAR complete all as specified and directed.
89Supply only Heavy duty resin filled power capacitor, 440V, 3 phase, 50 Hz, conforming to IS, IP 20 with over pressure disconnector, dielectric -MPP of 5 KVAR complete all as specified and directed.
90Supply only power factor controller of 8 step controller, complete all as specified and directed.
91Supply only power factor controller of 6 step controller, complete all as specified and directed.
92Supply only MCB SP, 6 to 32 Amp, 240 V, 10 KA \\"B\\" curve, IP 20, Conf to IS, complete all as specified and directed.
93Supply only control coil 230 V suitable for 4 Pole contactor, complete all as specified and directed.
94Supply only add on auxiliary contact block front mounting, 2 NO + 2 NC for 4 Pole contactor 25 Amp, complete all as specified and directed.
95S & F Air Circuit Breaker 4 Pole, 415 V, with Manual Drawout type with microprocessor release of capacity of 1250 Amps including accessories complete all as specified and directed.
96Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 120 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
97Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 35 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
98Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 50 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
99Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 70 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
100Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 95 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
101Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, heavy duty cable, 1100 volts grade, laid in trenches, passing through pipes/ducts, on walls with shadel, etc including taking out old unserveciable cable, any type with aluminium conductor of size 25 Sqmm nominal cross section x 3.5 core complete all as specified and directed.
102Supplying and laying Class LV, Type I, flat, size 250mm x 150mm x 40mmfor cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
103Deduct Schedule of credit (calculation will be done off line) Rs. 107214.00 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58445552
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 28-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance Of Dg Sets, Amf Panels, Apfc Panels, Water Flow Meters, Pressure Filter And Misc Works Bairagarh Military Station Under Ge Bhopal
Basic Detail
Tender No 8713/E8
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 07 Nov 2026
Submission Date 28 Nov 2026
Open Date 30 Nov 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
144e06f7-be7e-4f2a-b3a2-14a5297b9772.html
BOQ_895020.xls
credit8713.pdf
Tendernotice_1.pdf
TENDER_DOCU_8713.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Nov 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

144e06f7-be7e-4f2a-b3a2-14a5297b9772.html

xls

BOQ_895020.xls

pdf

credit8713.pdf

pdf

Tendernotice_1.pdf

pdf

TENDER_DOCU_8713.pdf

Disclaimer