Tender For Repair And Replacement Of Rcc/ Steel Pole, Lt Switch Gear, Lt Cable & Other Allied Wks At Army Area Under Ge Avadi
Tender Value
36 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
10 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Replacement Of Rcc/ Steel Pole, Lt Switch Gear, Lt Cable & Other Allied Wks At Army Area Under Ge Avadi
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables / pipes / erection of poles etc all as specified and as directed. |
| 2 | Excavation in trenches in soft/ loose soil not exceeding 1.50 m wide and exceeding 1.50 m in depth but not exc 3 mtr in depth for foundation of poles, stay, cable, pipes etc and getting out complete all as specified and directed |
| 3 | Supply and laying of common burnt clay building bricks, sub class B size for cable protection all as specified and as directed. |
| 4 | Laying in trenches fine sieved excavated dry soil including spreading/leveling, cushioning for underground cables all as specified and as directed. |
| 5 | Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed. |
| 6 | Removing excavated material(soil)not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed. |
| 7 | Material and labour for replacement of old unsv XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, 3.5/4 in replacement of the following sizes cross-sectionl area including taking down of old unserviceable cable/OH line ACSR conductor of any type complete all as specified and as directed:- (Note: Earth work and connected items will be measured and paid separately under respective items of schedule)(a) 16 sq mm 4 core |
| 8 | (b ) 25 sq mm 4 core |
| 9 | (c) 50 sq mm 3.5 Core |
| 10 | (d) 95 sq mm 3.5 Core |
| 11 | (e) 120 sq mm 3.5 Core |
| 12 | Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of following sizes including taking down old unserviceable one complete all as specified and as directed. (a) Bore of tube 40mm |
| 13 | (b) Bore of tube 50mm |
| 14 | M&L for replacement of old unsv Bus bar chamber and Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 No |
| 15 | M&L for replacement of olf unsv bur bar chamber and Supply ,Fabricate, install, connect, test and commissioning Busbar chamber, powder coated, outdoor weather proof type, compartmentalised fabricated with 3 mm thick CRCA steel and suitable sized pressed steel frame work, top with sloping canopy, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit , chamber for aluminium busbars, separate compartment for switch gear, louvers and air vent for natural air flow, holes drilled for connection including suitable angle iron/flat iron frame work/ supports, excavation, earth work, PCC foundation etc., as required with and including following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars including taking down the old busbar chamber and demolition of old plain cement concrete complete all as specified and comprising of the followings:- (i) 4 Nos busbar of equal size of Aluminium conductor with PVC coloured heat shrinkable type sleeves continuous rating of 400 Amps mounted on fibre reinforced insulator.(1set), with LED indication lamps-03 Nos for RYB phases on incoming side. (ii) MCCB fixed thermal magnetic release type of capacity 200 amps, 4 pole, 36 kA.- 1 Nos. (iii) On load change over siwtch 200 Amps ,4 pole 415 volts ,3 phase ,50 Hz AC - 01 NoNote : MCCB shall be front handle operated. |
| 16 | M&L for replacement of old panel and Supply.install,testing and commissioning of cubical outdoor LT Electrical distribution feeder pillar box CPRI approved platform mounted factory made totally enclosed dust and vermin proof (protection class IP-65) double shutter front opening with locking arrangement complete made thick frame work and 3.15mm thick CRCA sheet duly painted over outside and inside with detachable sheets with holes for cable glands,separate bus bars,cable entry and exit mounted on PCC pillers with bolts grounted complete .The panel comprising of Aluminium bus bars of 350 A capacity,415 volt 50Hz,3 phase 4 wire system with insulators and internal wiring complete with following requirements :-INCOMING :-Change Over MCCB ,200 Amp 4 pole, FE Frame,Ics=100% of Icu, 36 KA breaking capacity with adjustable Microprocessor release - 01 NoMCCB,200 Amp 4 pole, FE Frame,Ics=100% of Icu, 36 KA breaking capacity with adjustable Microprocessor release - 01 NoOUTGOING :-MCCB,100 Amp 4 pole, FE Frame,Ics=100% of Icu, 25 KA breaking capacity with adjustable Microprocessor release - 01 NoMCCB,63 Amp 4 pole, FE Frame,Ics=100% of Icu, 25 KA breaking capacity with adjustable Microprocessor release - 03 No MCCB,40 Amp 4 pole, FE Frame,Ics=100% of Icu, 25 KA breaking capacity with adjustable Microprocessor release - 02 No Indicating Lamp LED Type - 01 setMultifunction meter digital type -01 No |
| 17 | M&L for replacement of old panel and Supply.install,testing and commissioning of cubical outdoor LT Electrical distribution feeder pillar box CPRI approved platform mounted factory made totally enclosed dust and vermin proof (protection class IP-65) double shutter front opening with locking arrangement complete made thick frame work and 3.15mm thick CRCA sheet duly painted over outside and inside with detachable sheets with holes for cable glands,separate bus bars,cable entry and exit mounted on PCC pillers with bolts grounted complete .The panel comprising of Aluminium bus bars of 600 A capacity,415 volt 50Hz,3 phase 4 wire system with insulators and internal wiring complete with following requirements :-INCOMING :-MCCB,400 Amp 4 pole, FE Frame,Ics=100% of Icu, 36 KA breaking capacity with adjustable Microprocessor release - 01 NoOUTGOING :-MCCB,250 Amp 4 pole, FE Frame,Ics=100% of Icu, 25 KA breaking capacity with adjustable Microprocessor release - 01 NoMCCB,100 Amp 4 pole, FE Frame,Ics=100% of Icu, 25 KA breaking capacity with adjustable Microprocessor release - 04 NoIndicating Lamp LED Type - 01 setMultifunction meter digital type -01 No |
| 18 | Removal of UNSV RCC/PCC and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts, nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole etc complete all as specified and directed.(Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items) |
| 19 | M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed. |
| 20 | M&L for PCC ( 1:2:4) type B1 using 20 mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface. |
| 21 | M & L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed. |
| 22 | Material and Labour for replacement of old unsv MCCB 63 amps ,4 pole 415 volts ,3 phase ,50 Hz AC, 16 KA breaking capacity. The MCCBs shall have spreader links and barriers as standard feature of manufacturer including taking down old unserviceable one complete all as specified and as directed. |
| 23 | All as per above item No. 22.00 but of capacity 100 amps,3P, 25 Ka |
| 24 | All as per above item No. 22.00 but of capacity 100 amps, 4P, 25 Ka |
| 25 | All as per above item No. 22.00 but of capacity 125 amps, 4P, 25 Ka |
| 26 | All as per above item No. 22.00 but of capacity 160 amps,4P, 25 Ka |
| 27 | All as per above item No. 22.00 but of capacity 200 amps,4P, 36 Ka |
| 28 | All as per above item No. 22.00 but of capacity 250 amps,4P, 36 ka |
| 29 | All as per above item No. 22.00 but of capacity 320 amps,4P, 36 ka |
| 30 | All as per above item No. 22.00 but of capacity 400 amps,4P, 36 ka |
| 31 | M&L for replacement of old earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and electrode connections by using galvanised iron strip 25×4mm dia by means of bolts, nuts, check nuts and washers made of copper or brass and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board, and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, including excavation and earth work, disposal of surplus soil to a distance not exc. 50 mtr all as specified and as shown on Plate No 5 of SSR Part I (2009) all as specified and directed . |
| 32 | Material and labour for replacement of Earth continuity conductor or main earthing conductor 25mmx4mm galvanised iron strip, fixed to wall on batten with saddles and fixing screws or PVC/ Porcelain insulators etc. or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, including brazing on both sides (over lapping) at all joints complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents