Tender For Provn Of 02Xhigh Mast Light Alongwith 40X Flood Lights Along The Boundary Wall ,40X Security Lights Near Permanent Bldgs Incl Power Back Up 15 Kva Genr Set And Lightening Protection Sys Alongwith Chemical Earthing At Bldg No A-69 & A-71 At
Tender Overview
Project Description
Tender for Provn Of 02Xhigh Mast Light Alongwith 40X Flood Lights Along The Boundary Wall ,40X Security Lights Near Permanent Bldgs Incl Power Back Up 15 Kva Genr Set And Lightening Protection Sys Alongwith Chemical Earthing At Bldg No A-69 & A-71 At Signal Unit, Happy Valley At Shillong Under Ge Shillong.
BOQ
| Sl. No. | Item Description |
| 1 | M&L Sub main wiring with two run single core 1.5 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed or casing caping on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 1.5 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion complete all as specified and as directed. |
| 2 | S&F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. |
| 3 | M&L for switch piano (flush button type) single pole one way 6 Amps complete all as specified and directed. |
| 4 | Supply and fix in repair Bldg security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size including taking down old unserviceable one complete all as specified and as directed. |
| 5 | Supply and fix Cu termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 6 | Supplying & laying in trenches 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 7 | S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 mm X 6 mm copper strip complete all as specified and as directed. |
| 8 | S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm longhex. head screw complete all as specified and directed. |
| 9 | M&L for chemical pipe earthing electrode of size 3\\" dia (80 mm dia 03 Nos) and 3 m long of M series model M-392 or T-393 of make Ashlok /JMV, consisting of inner GI pipe (master) protected with outer zinc coated pipe with high crystalline conductive mixtures (CM) having anti corrosive and conductive properiy. Sealed in between the two pipe including threading on both the ends inciuding back fill compound (BFC) 3 bags filled surrounding the earth electrode according to manufactures instructions and all as specified and testing on completion including watering pipe 20 mm bore medium grade GI pipe, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate pit with and including 40 mm thick precast RCC (1:2:4) type B1 cover of size 50 cm X 50 cm with 8 mm round bar @ 15 cm C/C both way all as per electrical plate No 2 of SSR part-1, funnel including main earth lead from earth electrode to test point up to 7.5 M Copper strip 32x6mm complete all as specified and directed. |
| 10 | Supply,install, testing and commissioning of Silent Diesel engine driven generating set 415 Volts 3 phase 4 wire engine as per BS 5514/ IS 10002 including Emission control device as per PPCB Norms and alternator as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and foundation etc for capacity 15 KVA as per ISO - 3046/BS 5514 conforming to the detailed specification as under. make- Kirloskar Model No- KEC-T82.5-II or Greaves Power or Equivalent(A) ENGINE : The Diesel Enginewith AMF Panell shall be radiator water cooled, 15 KVA or 12 KW at 1500 RPM, Cylinder- 2 Nos. Starting stopping : Electrical start with 12 V DC 1 x 88 AH, 12 V Exide / Prestolite Low Maintenance Battery,Electronic governer , The fuel tank provided shall be suitably mounted on the base frame fabricated out of 16 SWG MS sheets and capacity to run the genset for 8 to 12 hours continuously on full load. Fuel tank shall have Drain plug, Hand hole for cleaning, vent breather, fuel suction and return connections, fuel level indicator fuel filling neck with cap etc as per the standards. The engine and alteranator shall be directly coupled to ensure perfect alignment. The engine and alternator shall be mounted on a common base frame with AVM pads all as per manufracturer CUMMINS / KIRLOSKAR / GREAVES POWER.(B) ALTERATION: Rating 15 KVA or 12 KW at 1500 RPM 415 V Phase to Phase and 240 Volt Phase to Neutral, 50 Hz 3 Phase 4 wire system , solid state Voltage Regulator,(+/-) 1 voltage regulation, alternato Screen protected / drip proof, self ventilating, self excited, self regulated, brushless, contineous duy protention IP 21 as per IS 13364 developing 20 KVA at 0.8 PF. It shall have provision for 10% overload for one hour on every 12 hours, The alternator shall confirm to IS : 13364/BS5000 Make : KIRLOSKAR / CROMPTON/ POWER GREAVES.(C) CONTROLS/PROTECTION: (i) Low LOP fault indication (ii) Indication for Water Temparature (iii) High Colant Temparature fault Indication (iv) Failure to start fault indication (v) Battery Volage monitoring (vi) Low Battery Indication (vii) Fuel level Indication (viii) Engine RPM meter (ix) Engine run hours meter (x) Voltage for all three Phases (xi) Amper meter for measuring current in all three phase. (xii) Frequency meter indication (xiii) Protection for Over/Under Voltage (xiv) Protection for Over/Under Voltage (xv) Electronic tamper proof KWH meter 3 phase, 4 wire system with suitable ratio CTs. (xvi) Oveload protection (xvii)Suitable capacity of Battery charger shall be provided in the control panel to charge the batteries when mains supply in availbale. When the Gen set is running the battery will be charged from the charging alternato. Make : KIRLOSKAR/ CROMPTON/GREAVES POWER. |
| 11 | (D) ACOUSTIC ENCLOSURE:(i) Shall be maticulously designed CNC Turret punch press and hydraulic press brake manufractured body out of corrossion resistant cold rolled steel 16 SWG CRCA / MS sheet duly surface trated phosphated and finally powder coated constructed from folded sections to ensure regidness and aesthatic in looks. Canopy panel and doors shall have High density/ fire retradent / non igniting and noise reduction type Foam or Resin bonded Rock wool of suitable density properly covered with fibre cloth / tissue and perforated fixed to absorb noise. The average sound levell when measure in greenfiled (ISO 8525 Part 10) at 1 meter distance from all four sides is less than 75 dB (A) average as per CPCB Norms The average stablised hot air temperature rise with the canopy near suction air filter to be maintained 7 degree centigrade over and above the ambient temperature Four higned doors shall be provided to canopy one door shall have glass window for control panel. The exhaust gasses shall be taken out through a suitable flexible pipe to prevent any back pressure on the engine. Provision shall be made on the canopy for connectig the output cable terminatiion should be provided. (ii) The eshaust system and noise suppressor shall be provided with thermal insulation, to prevent excess heat radiation on the Engine and safe for operator. (iii) Absorbtion type non residential silencer insulated from inside with glass wool shall be provided to suppress exhaust noise from the Engine. (iv) A suitably designed draught ventilation system is to be incorporated. make:- Kirloskar green /Jackson /Powerwool(E) DG power Control Panel : (i) Shall be outdoor type sheet steel type cubicle type control panel ,floor standing, dust and vermin proof under normal conditions complete with all internal wiring & will house the following:- (a) AC voltmeter (b) AC ammeter (c) vibrating reed Frequency meter (d) Indicating Lamps for SET ON & LOAD ON (e)MCCB for short circuit & Overload Protection (f) Aluminium Bus bars of adequate rating (g) Provision for bottom entry & Exit of power cabling (g)set of current transformer (h) set of control fuses |
| 12 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 14 | Removing excavated material not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 15 | M&L for cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate in copping of electric poles or roof kerbs or mud stops, rounded or chamfered on edges or slab staging for water tank or filling of chowkhats complete all as specified and as directed. |
| 16 | Supplying & laying, in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 including taking down old complete all as specified and as directed. |
| 17 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. Note :- Only punned down sand shall be measured. |
| 18 | M&L for bricks, common burnt clay building bricks, sub- class 'B' designation 75 complete all as specified and directed. |
| 19 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 20 | M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 21 | Supply & installation of Galvanized steel high mast lighting system of 12.5 meter in two section, 3 mm section thickness, top dia 150 mm, bottom dia 340 mm, with 2/3 wire rope system and its accessories. System is suitable for loading 06 nos 50 to 120w LED Lights complete all as directed and specified. |
| 22 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as directed. |
| 23 | M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. NOTE :(i) Item 5 If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.(ii) Length of earth strip/electrode beyond 7.5mtr shall be measured and paid under relevent item of this BOQ. (iii) Resistance value shall be less than 1 ohm.(iv) Copper plate shall be of 99.99% copper. |
| 24 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 25 | S&F flexible wire of size 6 Sqmm 3 core copper conductor fixed with clamps complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender