Tender For Special Repair To South Gate And Main Gate At Af Stn Darbhanga Under Ge Af Bihta.
Tender Value
20.33 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
18 days left
EMD
40660
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darbhanga → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To South Gate And Main Gate At Af Stn Darbhanga Under Ge Af Bihta.
BOQ
| Sl. No. | Item Description |
| 1 | B/R WORKS |
| 2 | PCC type B-2 (1:2:4), using 40 mm graded stone aggregates as in foundation, filling & mass concrete, complete all as specified. |
| 3 | Cement concrete, type D-2 (1:4:8), using 40 mm graded stone aggregates as in sub base floor foundation, filling & mass concrete, complete all as specified. |
| 4 | Brick work using sub slass 'B' bricks straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 5 | Prelaminated particle board of thickness 12 mm , exterior grade, prelaminated both side with decorative choice lamination, fixed to aluminum door as per direction of Engr-in-charge |
| 6 | Stainless steel 100mm long butt hinges with stainless steel screws, ISI marked complete all as specified. |
| 7 | Extruded aluminium anodised handles fabricated type with plate 150 mm long, ISI marked complete all as specified. |
| 8 | 04 levers brass mortice lock, vertical type, 100 mm size, with 2-3 keys, complete all as specified. |
| 9 | Aluminium (Die cast) door closer hydraulically regulated designation No. 3 aluminium body universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg, ISI marked, complete all as specified. |
| 10 | Stainless steel alphabet letters of standard pattern & of size (450mm x 300 mm ) , 50 mm wide and 15mm thick.The thickness of stainless steel sheet shall be 15 mm & grade of sheet shall be 304 AISI including fixing to metal board/ wall with screw or welded complete all as specified and directed. |
| 11 | Powder coated aluminium frame for doors, windows, ventilators, fixed glazing with one or more rebates including joining cleat for fixing, fixed to opening with suitable size steel screws and rawl plugs etc. complete all as specifiedNote :Powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. |
| 12 | Powder coated aluminium door shutters with styles & rails , anodised alumnium glazing snap beading , rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 200 mm long almn handles and 03 No. 100 mm size stainless steel/almn butt hinges.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron.(d) aluminium section not less than 2 mm. |
| 13 | Powder coated aluminium window and ventilator shutters side hung type with styles & rails , anodised alumnium glazing snap beading , rubber neoprene packing including joining cleats & screws etc as per manufacturers instructions, complete all as specified. NOTES: (a) Each shutter shall have 2 Nos. 125 mm long almn handles and 02 No. 75 mm size stainless steel/almn butt hinges & one no. almn hook & eye.(b) Glass and other filling materials in panels including wire cloth and almn grill shall be measured & paid for separately under respective item of BoQ.(c) For powder coated aluminum sections minimum thickness of powder coating shall be 50 micron. |
| 14 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face 1 and polymer (Service) coating on face 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 15 | (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places |
| 16 | MS framed work as in door or gates of angle or other section with gusset plates, rails, braces, etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete confirming to Fe-290 Gde-E-165 complete all as specified and directed |
| 17 | 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified. |
| 18 | Granite any shade, 16-20 mm thick,as in step, jambs, skirting, cooking platform and like, machine cut, machine polished, bedded and jointed with grey cement slurry & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:4), complete all as specified. |
| 19 | Coloured vitrified (double charged) ceramic tiles 9-10mm thick (square/ rectangular) area of each tile n. exc. 0.36 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 20 mm thick bedding layer in cement mortar (1:6), complete all as specified. |
| 20 | Factory made rubber moulded pre polished lacquer finish, PCC colured chequered tiles, ISI marked, 25 mm thick, of size 300 mm x 300 mm, in floors, over & including 20 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete, all as specified. |
| 21 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6), complete all as specified. |
| 22 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), , complete all as specified. |
| 23 | Prepration of new plasterd wall surfaces of any description and applying Two coats of interior acrylic distemper over and including a coat of acrylic emulsion primer complete all as specified |
| 24 | Prepration of new plasterd wall surfaces of any description & applying Two coats of exterior acrylic emulsion over and including a coat of water based exterior primer complete all specified |
| 25 | One coat of white washing on old decorated ceiling surfaces, including preparation of surfaces, complete all as specified. |
| 26 | Sheet glass 5.5 mm thick ordinary quality and glazing with oil putty / aluminium beading in squares n. exc. 0.5sqm in each pane complete all as specified. |
| 27 | Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified. |
| 28 | E/M WORKS |
| 29 | Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI sunken boxes made out of 1.2mm thick MS sheet, 60mm deep concealed in wall modular metal flush box & including modular cover plate with frame having necessary cutting for fixing switches/ sockets comprising the following: - |
| 30 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 31 | One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified. |
| 32 | One socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable &1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 33 | One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit not less than 20mm dia all as specified. |
| 34 | NOTES: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4). |
| 35 | Switch modular type single pole one way, 6 Amp, 1 module complete all as specified. |
| 36 | Switch modular type single pole one way, 16 Amp, 1 module complete all as specified. |
| 37 | Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, 2 Module complete all as specified. |
| 38 | Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, 2 Module complete all as specified. |
| 39 | Modular type RJ 45 with two module with shutter complete all as specified. |
| 40 | Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified. |
| 41 | Lamp (angle) holder, PVC/ polycorbonate type with back plate suitable for batten fittings complete, all as specified. |
| 42 | Sub main wiring 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable (with approved colour coding as per IS) with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, with and including rigid non metallic PVC medium duty concealed conduit not less than 25mm dia complete all as specifiedNOTES: (i) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as \\"1 RUNNING METRE\\" |
| 43 | Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection with magnetic locking system, including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing surface, IN REPLACEMENT, complete all as specified comprising the following: |
| 44 | SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type. |
| 45 | SPN, 6 way with 100 Amp rated bus bar, 415 V, double door type |
| 46 | TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type |
| 47 | MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified. |
| 48 | MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp complete all as specified. |
| 49 | MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 100 Amp complete all as specified. |
| 50 | LED bulb 9 / 10watt B-22 Cap, highly efficient complete all as directed. |
| 51 | Surface mounted Environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD<10% LED 20 W lighting fixture with extruded polycarbonate, 6500K, lumen output should not be less than 90 lumens per watt, IN REPLACEMENT, complete |
| 52 | LED flood light 150 watt suitable, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W IP 66 protection, IN REPLACEMENT, and making connections, complete. |
| 53 | LED street light fittings 35 watt, outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and lamp with minimum efficiency 110 LM/W, IP 66 protection, and making connections with 1.5 Sq.mm copper conductor PVC insulated three core weather proof cable, IN REPLACEMENT, complete all as specified |
| 54 | Security light bracket made of 40 mm bore GI light grade pipe 1.5 metre long bend to shape including necessary welding to pole(s) or fixed with suitable size of flat iron clamps, nuts, bolts and washers etc. IN REPLACEMENT, wit & including two coats of synthetic enamel paint over a coat of primer complete all as specified |
| 55 | Street light junction box of size 250mm x 200 mm x 150 mm complete with shock and rust proof, termite resistance, tamper proof, front openable type and including suitable provision for single phase, two wire cable (Size upto 25 Sqmm 2 Core ) incomming & outgoing loop connection and including one no MCB SP 6 Amp including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole /wall complete |
| 56 | GI earthing wire of size 4mm including fixing in wall with proper nuts, bolts, washer etc complete all as specified. |
| 57 | Dismantling of complete defective ceiling fan of 1200 mm sweep (i.e.,) down rod with its Canopies, Shackle, Blade, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, ( weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed & specifications and as directed by Eng-in-Charge. (b) Re-assembling complete ceiling fan by fixing only serviceable of old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushed, blades, ball bearing, twin twisted copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, painting, cleaning outer body & surfaces etc complete all as specified and directed. |
| 58 | Excavation in trenches in SOFT/LOOSE soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, taking out/ laying pipe line, cable etc. and getting out complete, all as specified. |
| 59 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified. |
| 60 | Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified. |
| 61 | Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified.NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 62 | Brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed |
| 63 | Cutting the existing road straight by manual, depth and width not less than 1 metre below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 using 20mm graded aggregate stone complete all as specified. |
| 64 | Supply, laying, jointing & testing of LT XLPE insulated cable of sectional area 16 sqmm 2 core screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including takind down existing cable complete all as specified . |
| 65 | Steel tubes 50mm bore ‘light grade’, with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including takind down existing pipe complete all as specified . |
| 66 | Earthing to panel with galvanised steel plate electrode 600 mm x 600 mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal groung level) with top edge of earth lead wire 4.0 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule pt-I 2009, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover, reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, using round bar, PGI funnel with wire mess & frame, PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. IN REPLACEMENT, complete all as specified. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) Earth resstance shall be less than 3 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt. |
| 67 | Demolition and Dismantling work |
| 68 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sq.m each and removing from site all as specified. |
| 69 | Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 70 | Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 71 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 72 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified. |
| 73 | Dismantling structural steel work including doors gates and single section (old SS alphabet letters) but excluding framed truss etc of any description, complete all as specified. |
| 74 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 75 | Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified. |
| 76 | Note : Amount of credit for retrieved materials is mentioned in Sch of credit of tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 28, 2026
17:00 IST