Tender For Tedc / Tirupur - Construction Of New Office Building To Accommodate The Aee/O&M/Town West/Tirupur & Aee/O&M/Town North/ Tirupur [ Upgraded Sections] At Kumar Nagar Eb Campus, Tiruppur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Nov 2026
0 days left
EMD
58400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruppur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tedc / Tirupur - Construction Of New Office Building To Accommodate The Aee/O&M/Town West/Tirupur & Aee/O&M/Town North/ Tirupur [ Upgraded Sections] At Kumar Nagar Eb Campus, Tiruppur
BOQ
| Sl. No. | Item Description |
| 1 | Clearing Scrub jungles with uprooting, disposed from the site including cost of all labour, lead, lift, T&P, etc., complete. |
| 2 | Earth work excavating and removing soil heaps/construction waste/debris in large tree root masses for levelling of site in all types of soil, trasnporting excess soil away from site, etc., complete as per standard specification |
| 3 | Earth work excavating and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders for building substructure components |
| 4 | Earth work excavating and depositing on bank with initial lead of 10m and Initial lift of 2m in Soft Disintegrated rock, laterite, soft rock or kankar, not requireing blasting for building substructure components |
| 5 | Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in medium rock and dense medium rock, not requiring blasting for building substructure components |
| 6 | Removing hard rock by wedging, chiselling and trimming to proper shape where blasting is prohitibed for building substructure components |
| 7 | Providing anti-termite treatment over the plinth area of building [Foundation stage, flooring stage and out side of the building] as per standard specification. |
| 8 | Supply, filling with M.Sand for foundation, Basement,etc., including cost of material, labour, lead, lift, consolidation, etc., complete. |
| 9 | PCC 1:3:6 using 20mm HBGS for foundation, basement including cost of all materials, labour, lead, lift, etc. complete. |
| 10 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete.(For Raft Concrete) |
| 11 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Column Concrete -Upto Ground Level) |
| 12 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Column Concrete -Above Ground Level to Roof Level) |
| 13 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Column Concrete -Abover GF Roof Level) |
| 14 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Grade Beam & Plinth Beam Concrete) |
| 15 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Sill Beam Concrete) |
| 16 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Lintel Beam Concrete) |
| 17 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Sunshade/Loft Concrete) |
| 18 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Roof Beam Concrete) |
| 19 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Roof Slab Concrete 125mm Tk) |
| 20 | RCC 1:1.5:3 using 12-20mm HBGS with formwork including cost of all materials, labour, lead, lift, formwork, curing, etc., complete. (For Staircase Slab Concrete 150mm Tk) |
| 21 | Brick work in CM 1:5 using II class champer burnt bricks for super & substructure, partition wall, including cost of all materials, labour, lead, lift, etc., complete. |
| 22 | Brick work in CM 1:3 using II class champer burnt bricks for super & substructure, partition wall, including cost of all materials, labour, lead, lift, etc., complete. |
| 23 | Providing & placing of steel reinforcement for All RCC works including cost of steel rod, binding wire, other materials, labour, T&P, lead, lift, etc., complete. |
| 24 | Plastering with CM 1:5, 12mm thick in sub/super structure including cost of all materials, labour, scafolding, lead, lift, scaffolding, curing, etc., complete. |
| 25 | Plastering with CM 1:3, 12mm thick for ceiling including cost of all materials, labour, lead, lift, scafolding, curing, etc., complete. |
| 26 | Flooring with PCC 1:2:4 using 12-20mm HBG metal for basement, Plinth protection with smooth finishing, Column Footing including cost of all materials, labour, lead, lift, formwork, etc. complete. |
| 27 | Providing PVC down fall pipe using 110mm dia 4 Kg/sqcm PVC pipe including cost of all materials, labour, fixing in position from roof top with clamp, door specials, lead, lift, etc., complete |
| 28 | Providing two coats of wall putty of approved quality over the Interior plastered surface including removal of loosly adhering materials with emery stone/putty blade/wire brush, wetting of surfaace including cost of all materials, labour, lead, lift, etc., complete. |
| 29 | Painting with two coats of interior emulsion of approved quality and colour over a priming coat for interior wall surfaces, ceiling including cost of all materials, labour, lead, lift, T&P, etc. complete. |
| 30 | Painting with two coats of exterior emulsion of approved quality and colour over a priming coat for exterior wall surfaces including cost of all materials, labour, lead, lift, T&P, etc. complete. |
| 31 | Flooring with Vitrified tiles 600x600x8mm thick of approved Quality, design & colour laid in CM 1:3-20mm thick including pointing with same coloured cement using 0.4kg/Sqm, finishing the joints, including cost of all materials, labour, lead, lift, curing, etc., complete. |
| 32 | Flooring with Non-Slippery cermamic floor tiles 305x305x6mm thick of approved quality, design & colour laid in CM 1:3-20mm thick including pointing with same coloured cement using 0.3kg/Sqm, finishing the joints, including cost of all materials, labour, lead, lift, curing, etc., complete. |
| 33 | Dadooing wall with Glazed tiles 300x200x6mm thick of approved quality, design & colour laid in CM 1:2-10mm thick including pointing with same coloured cement using 0.3kg/Sqm, finishing the joints, including cost of all materials, labour, lead, lift, curing, etc., complete. |
| 34 | Supplying and fixing UPVC Casement Door with Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. |
| 35 | Supplying and fixing UPVC Windows with profile: The size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should Nost allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting Nosise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work cost of all materials , lead, lift , etc. complete, as per standard specification |
| 36 | Supplying and fixing UPVC Louvered Ventilatorsof from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames |
| 37 | Supplying and fixing PVC Panelled Door Shutters Hollow Type - 200mm x20mm panels with 1mm wall thickness for panels and styles and rails of suitable size with 2mm wall thickness suitably reinforced using MS Angle / Flat including cost of necessary aluminium hinges and other furniture fittings |
| 38 | Supply and fixing of white wash hand basin of size 550 x 400mm (without pedestal) to the wall in position with all accessories like cast iron brackets, waste coupling, rubber plug and chain, waste pipe, angle valve, nylon connection, pillar tap, nipple, etc., complete. |
| 39 | Supply and fixing of PVC/fibre glass framed 5.5mm thick 500x400mm mirror, shelf type with hard board backing to the wall in position with all accessories, etc., complete. |
| 40 | Supplying and fixing in position Oriya Type Indian Water Closet 580mm x 440mm of best quality and approved make with “P” or “S” trap with all internal fittings and fixtures, necessary masonry work for fixing, labour, lead, lift, etc., complete. |
| 41 | Supplying and fixing in position White Glazed Floor Mounted European Water Closet of best quality and approved make with “P” or “S” trap and with double flapped seat and seat cover and 12.5 litres capacity PVC low level flushing tank, PVC flush hand, nylon connection, PVC 1.5m health faucet and all internal fittings & fixtures such as two way bib tap, ball valve, union coupling , necessary masonry work for fixing, labour, lead, lift, etc., complete |
| 42 | Supplying and fixing in position lipped mouth porcelain flat back urinal with all accessories such as push tap, connection pipe, nipple, waste water pipe, labour, lead, lift, etc., complete |
| 43 | Supplying and fixing in position of polished granite slab 18-20mm thick for urinal partiton in wall with necessary masonry work for fixing including all necessary materials, labour and disposal of dismantled material i/c malba etc., complete |
| 44 | Supplying & laying in position of PVC soil / waste / vent pipes of 110 mm - 6 kg / sq.cm. working pressure including cost of cutting, joining and fixing PVC specials/fittings with door at major junctions using adhesives, providing leak proof joints, masonry work, etc. complete |
| 45 | Supplying & laying in position of PVC soil / waste / vent pipes of 50mm - 6 kg / sq.cm. working pressure including cost of cutting, joining and fixing PVC specials/fittings with door at major junctions using adhesives, providing leak proof joints, masonry work, etc. complete |
| 46 | Supplying & laying in position of UPVC soil / waste / vent pipes of 50 mm including cost of cutting, joining and fixing UPVC specials/fittings with door at major junctions using adhesives, providing leak proof joints, masonry work, etc. complete |
| 47 | Supplying and fixing in position PVC Nahani Trap / Floor Trap of 100 x 75 mm sizes with best PVC gratings including necessary masonry works, giving connection to PVC waste pipes, etc., complete. |
| 48 | Supply and delivery and fixing of PVC readymade water tank 1000 Litres capacity including loading, unloading, transportation, lead, lift, labour charges for fixing of pipes and specials for water supply connection works including cutting, threading and fixing charges, etc., complete |
| 49 | Supplying & laying in position of UPVC water supply pipes of 25 mm dia having 10 kg / sq.cm. working pressure including cost of cutting, joining and fixing UPVC plain/brass threaded fittings/specials using adhesives and fixing clamps, providing leak proof joints, exposed on wall internal/external work, etc., complete |
| 50 | Supplying and fixing in position of UPVC Long Body Tap 15/12 mm dia to water supply line, including cost of material, labour, lead, lift, etc., complete. |
| 51 | Supplying and fixing in position of UPVC Ball valve 25mm dia to water supply line, including cost of material, labour, lead, lift, etc., complete. |
| 52 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light point / fan point |
| 53 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed PVC plug point |
| 54 | Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box for 15A 3 pin non inter locking wall socket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4 sq.mm copper wire for concealed PVC power plug point |
| 55 | Supply and fixing of 4' 20W LED fitting with LED complete on wall/ceiling with PVC unsheathed Copper leads from terminal to the fitting. |
| 56 | Supply and fixing of 9W LED bulb on wall/ceiling with battern holder, PVC unsheathed Copper leads from terminal to the fitting. |
| 57 | Supply and fixing of 30W LED street light fitting with LED with 25mm dia GI pipe, 1 No GI bend on wall with PVC unsheathed Copper leads with MS clamp. |
| 58 | Supplying and fixing of 1400mm sweep AC ceiling fan with stepped electronic regulator with 300 mm down rod with clamp. |
| 59 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall |
| 60 | Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion with suitable colour |
| 61 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark |
| 62 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 mA Four Pole RCD / RCCB (Higher End) with suitable necessary connection |
| 63 | Supply and run of 3 x 7/18 PVC Insulated Unsheathed Solid/Stranded Copper Wire VIR Cable on 7 / 20 GI bearer wire for service connection mains |
| 64 | Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work |
| 65 | Supplying and fixing of 1HP Mono block pump with all accessories of approved quality and of reputed make including cost of all materials, labour for fixing in position, lead, lifts, 25A DP switch, copper flat cable, etc., complete. |
| 66 | Supply and fixing of surface mounting CAT 6 PVC module gang box with single socket RJ-45 face plate & RJ-45 CAT 6 Keystone jack on surface mounted gang box for data outlet on wall/ partitions including crimping of UTP/Telephone cable with keystone jack complete, etc., complete |
| 67 | Supply & run of unarmoured CAT-6 Lan cable for data connectivity framework b/w switches & Gang box, inside PVC conduit system inflush with wall and ceiling, including connections, testing and commissioning complete. |
| 68 | Supply & fixing of 8-Port 10/100Mbps LAN network switches on surface by wall mounting including bunching of cables, connections, testing and commissioning complete |
| 69 | Refilling with excavated earth other than sand in foundation, basement and sides of masonry, consolidation as per std.specn.with water including all labour, T&P, lead , lift, etc., complete. |
| 70 | Transporting of excess excavated soil away from the site to the nearby bund or low lying area shown by the departmental officers complete |
| 71 | Supplying and filling of gravel complying with standard specification for filling in foundation & basement, well rammed, watered and consolidated etc. complete |
| 72 | Supply, fabrication and fixing in position of tubular steel sections of various profile to support overhead water tank, Truss members, etc., including cost of all materials, labour, lead, lift, hoisting, with connection details of Bearing plate, anchor bolts, gusset plate, cleat angle, T&P, etc., complete. |
| 73 | Supply, fabrication and fixing in position of MS grill as of approved design including cost of all materials, labour, lead, lift, taking grooves in BM/RCC, packing the pockets with CC and painting with one coat metal primer, hoisting, T&P, etc., complete. |
| 74 | Painting new iron works such as tubular steel sections of various profile to support overhead water tank, Truss members, etc., with two coats of synthetic enamel paint of approved colour over one coat of red oxide primer including cost of all materials, labour, scaffolding, lead, lift, T&P, etc., complete |
| 75 | Painting new iron works of MS grill with two coats of synthetic enamel paint of approved colour including cost of all materials, labour, scaffolding, lead, lift, T&P, etc., complete |
| 76 | SGST & CGST (If applicable quote the value or enter '0') |
| 77 | IGST (If applicable quote the value or enter '0') Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓