Tender For General-Development Of Regional Fisheries Technical High School ,Koyilandy,Kozhikode- Maintenance Of Electrical Works -General Electrical Work(Re-Tender)
Tender Value
36.49 Lakhs
Estimated cost
Bid Submission
16 Nov 2026
2 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kozhikode → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Development Of Regional Fisheries Technical High School ,Koyilandy,Kozhikode- Maintenance Of Electrical Works -General Electrical Work(Re-Tender)
BOQ
| Sl. No. | Item Description |
| 1 | Point Wiring |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 4 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 5 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 6 | 1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 7 | Sub-Circuit Wiring |
| 8 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 9 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 10 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 11 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 12 | 1.17.32:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm |
| 13 | Networking |
| 14 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 15 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 16 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 17 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 18 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 19 | 90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 20 | 90.9.2.6:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler |
| 21 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 22 | 90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer |
| 23 | 90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box |
| 24 | 1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module |
| 25 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 26 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 27 | OD174851/2026-2027:Supply and installation of 9U wall mountable Network rack Conforms to DIN 41494 or equivalent standard, Lockable Toughened Glass Door, DIN Standard Slots, Powder Coated, Grey or black colour, made from Mild Steel, (L55 x W45 x H46 cm), power distribution unit, cooling Fan, including screws and other accessories to mount the rack (Make: Dlink or equivalent make approved by CPWD/KPWD/KSCADC) |
| 28 | OD180698/2026-2027:Supply of Wireless Fiber Router (Black, Dual Band) with 2 External Dual Band Antennas, Easy RemoteManagement. Superfast Dual Band Wi-Fi ---- Up to 1.2Gbps Wi-Fi speed, 300Mbps 2.4GHz, 867Mbps5GHz Full Gigabit Port ---- Up to 10x faster than standard Ethernet, deliver lightning-fast wiredperformanceSupports VOIP Calls ---- Simply make or receive phone calls over the InternetEasyRemote Management ---- Supports the ONT Management and Control Interface (OMCI), easy toconfigure and manage remotely from an OLTSmooth Connection ---- Supports VLAN, 802.1q,smooth network connection for IPTV and other services (Make: DLink, TPLink... or equivalent makeapproved by CPWD/KPWD/KSCADC) |
| 29 | OD180700/2026-2027:Supply of 20M 4K Original HDMI Cable, High Speed 18Gbps 4K@60Hz 2160P,Ultra HD,3D,1080p,Ethernet Compatible for TV, Laptop, PC, Monitor & Projector (Black), Gold-plated full metal connector is corrosion-resistant, metal alloy casing with PVC jacket structure prevents signal degradation orattenuation, provide lag-free and uninterrupted viewing experience.1 Year Warranty. (Approved make byCPWD/KPWD/KSCADC) |
| 30 | OD180708/2026-2027:Supply and fixing of Motorized Projector Screen, Size: - 8 Ft. (Width) x 6 Ft. (Height), in 4:3 Aspect Ratio,120 Inches Diagonal Length, supports 1080 P, 3D and 4K Viewing Technology (White). wall and ceilingmounting type. END TO END LEFT TO RIGHT HORIZONTAL METAL CASING. 180 Degree ViewingAngle for commercial or residential presentations. (Make: Inlight or equivalent make approved byCPWD/KPWD/KSCADC) |
| 31 | OD180770/2026-2027:Supplying and fixing of casing and caping of following size on surface along with accessories.20mm/25mm (Approved make by CPWD/KPWD/KSCADC) |
| 32 | OD180771/2026-2027:Supply, installation and commissioning of 1080P Fully Automatic 4K HDR Projector for Home, Hall...,Ultra Bright 750 ANSI, (Intelligent OA + Screen Fit), HDMI ARC, Android 9, BT 5.1, WiFi 6, 2GB 32GB.Display Type: LCD. Display Features : Ultra Bright Projector - Resolution Native 1080P with 4K HDR +HLG Support - 11600 Lumen High Brightness (US Standard 750 ANSI) - 7000:1 Static Contrast Ratio,110% NTSC Wide Color Gamut - 762 cm (300 inch) Max Screen size ? LTPS Technology | LifelongLamp\\" - 30000 Hour. Intelligent Screen Adjustments (Auto Focus + Auto Keystone + Auto Tilt + AutoScreen Fit + Auto Obstacle Avoidance), Next Gen Wi-Fi 6 + Dual Band Wi Fi (2.4 Ghz + 5 Ghz) - HDMIARC + LAN + SPDIF - Audio Out, Bluetooth Out, Bluetooth In - HDMI ARC - USB - Wireless ScreenSharing. 10 Watt Hi-Fi Stereo Output via built in Speakers + Passive Bass Radiator. Powered by 15-WattIndependent DSP amplifier delivering immersive sound. HDMI ARC for 5.1 Surround. NationwideWarranty Coverage. (Make: WZATCO Alpha X or equivalent make approved by CPWD/KPWD/KSCADC) |
| 33 | OD180772/2026-2027:Supply and mounting of Heavy Duty - 2 feet to 3 feet/Foot (24 inch to 36 inch) Adjustable ProjectorCeiling and Wall Mount Kit Bracket Stand with Tilt Option (Weight Capacity - 15kgs) (Black - 3 Feet) |
| 34 | OD183414/2026-2027:Supply, crimping, fixing and installation of RJ45 Connector Module Plugs. (Make:D-Link or equivalent make approved by CPWD/KPWD/KSCADC) |
| 35 | Switches & Sockets |
| 36 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 37 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 38 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 39 | 1.57:Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD |
| 40 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 41 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 42 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 43 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 44 | Conduit |
| 45 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 46 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 47 | OD174953/2026-2027:Supply and fixing of flexible conduit of the following size, as required - 20mm |
| 48 | OD184958/2026-2027: Supply and installation of PVC Conduit Adapter, 25mm. |
| 49 | 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps |
| 50 | 90.11.1.20:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 51 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 52 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 53 | 2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 54 | 2.4.2:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18), Double door |
| 55 | 2.4.3:Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way(4+24), Double door |
| 56 | 2.5.1:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 WAY(4+12), DOUBLE DOOR |
| 57 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 58 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 59 | OD175033/2026-2027:Supply, installation and commission of TP, 40A, 415V MCB, 'C', curve, 10kA inside DB (Make: Legrand DX3, ABB or any equivalent make approved byKPWD/CPWD/KSADC) |
| 60 | OD175087/2026-2027:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required.<br>25A |
| 61 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 62 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 63 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 64 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 65 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 66 | 2.23.4:Supplying and fixing Cable End Boxes (IP 43) suitable for following single poleand neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with testing and commissioning etc. as required.For 14 way, Double door SPN MCBDB |
| 67 | 2.24.2:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB |
| 68 | 2.24.3:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB |
| 69 | 2.25:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 70 | OD175250/2026-2027:Supply and fixing of Four pole, 16SWG, powder coated metallic enclosure, singledoor on surface/recess without MCB/Isolator/RCCB |
| 71 | OD180399/2026-2027:Supply, Installation and Commissioning of SP, 40A, 240/415V 'C' Curve, 10kA MCB in existingenclosure/DB (Make: Legrand, Havells, L&T or any equivalent make approved byKPWD/CPWD/KSCADC) |
| 72 | Cable |
| 73 | 90.12.6.3:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 10 sq mm |
| 74 | 90.12.6.29:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm |
| 75 | 90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm |
| 76 | 90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 77 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 78 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 79 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 80 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 81 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 82 | OD175365/2026-2027:Supply and installation of 4 sqmm to 16 sqmm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands and giving all connections.<br> |
| 83 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 84 | 90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm |
| 85 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 86 | 7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 87 | OD175379/2026-2027: Supply and installation of water proof submersible tape 1inch X 1feet |
| 88 | OD175381/2026-2027:Supply of Cable Tie |
| 89 | OD180437/2026-2027:Supply and installation of Copper shim for earthing the glands of cable from 25 sqmm to 95 sqmm, 60mm long x 20 mm wide x 1.20 mm thick. including accessories Copper earthing clips for singlecompression glands |
| 90 | Grounding |
| 91 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 92 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 93 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 94 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 95 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 96 | 5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 97 | Energy Meter |
| 98 | OD175418/2026-2027:Supply and installation of weatherproof three phase Energy meter fiber box withprovision for HRC fuses - 3Nos., Neutral Link - 1No. and a 4P isolator. DoubleDoor. |
| 99 | 2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 100 | OD180050/2026-2027:Supply and installation of following HRC fuse holder with HRC fuse link insidepanel board/ energy meter box, any make approved byCPWD/KPWD/KSCADC 100A |
| 101 | OD180452/2026-2027:Supply and installation of following rated 2 Way neutral links mounted on DMC/SMC base on panelboard/enclosure, as required. 100A |
| 102 | Fittings |
| 103 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 104 | OD176956/2026-2027:Supply, installation and commissioning of 9W, 240V LED Bulb (PWD approved make) |
| 105 | OD176997/2026-2027:Supply of exhaust fan louver for the following size on the existing exhaust fan, indoor/outdoor usage, silver colour, adjustable, frame made with galvanized sheet and flappers made up with aluminium. (Make must be approved by CPWD/KPWD/KSCADC) 450mm. |
| 106 | OD177006/2026-2027:Supply and Installation of 150mm sweep Light Duty Exhaust fan in plastic body with self-opening lowers working on 230V single phase A/C. Approved make by CPWD/KPWD/KSCADC. |
| 107 | OD177015/2026-2027:Supply, installation and commissioning of Exhaust fan having 225mm sweep in plastic frame body working on 240V AC supply on wall, giving proper connection and dressing of the cable with all necessary accessories. |
| 108 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 109 | 90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required. |
| 110 | 90.5.1.10:Gong bell 300mm-without MS box |
| 111 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 112 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 113 | OD177082/2026-2027:Supply, Installation and Commissioning of water purifier (table top model) With inbuilt UV+RO purification and HOT-NORMAL option with the features 1) Duel filtration prior to purification(spun catridge and ac carbon) 2) Duel purification with UV plus Reverse Osmosis to treat hard water 3) Faucets-2 to deliver purified normal and hot water. 4) TANK MAKE: 304 S.S(for all tank) all tanks<br>are SS 5) Body : Special grade 202 SS/304 0.8 mm 6) Heat temperature:50oC-80oC 7) Warranty: One year from the date of installation (Make: Chris SPARKLE- 30 NH, Blue star or equivalent make approved by CPWD/KPWD/KSCADC) |
| 114 | 1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required. |
| 115 | OD180539/2026-2027:Supply and Fixing of 9W LED Bulk Head |
| 116 | OD180571/2026-2027:Supply, installation, testing and commissioning of 400mm sweep wall mounting fan including allnecessary accessories (Make must be an approved one by CPWD/KPWD/KSCADC) |
| 117 | OD180660/2026-2027:Supply and fixing of Anchor Steel Double D-Hook Hanger (Heavy Duty) with Fasteners forHanging Chandelier, Ceiling Fan or Jhoomer, Golden (Double D Hook). consists of 1 Pc. of DHook& 2 Pcs. of heavy-duty Fasteners (M10x75mm). Specially designed to hang Ceiling Fans,Jhoomer, Baby Swings, Ropes, etc. Pull out load is 75 Kgs and Jurk/Vibration load is 40 Kgs.Need to use 10 mm diameter drill bit for drilling holes on ceiling or wall to fix Fastener. Thedrilling depth should be greater than or equal to 65 mm. Fastener outer diameter approx. 10mm. Approved make by CPWD/KPWD/KSCADC) |
| 118 | OD180670/2026-2027:Supply and fixing of ceiling fan capacitor - 2.5mfd |
| 119 | OD180774/2026-2027:GENERAL PURPOSE LUMINAIRES. Supplying, installation, testing and commissioning of followingSLEEK RD- surface mounted or recessed Round or Square/ Round Down light Sleek surface 18W/20WWH RD cool white LED down light for soft diffused lighting complete light out put on ceiling / wallincluding connection with 1sq.mm FRLS PVC insulated copper conductor multi stranded three core cableetc as required, Brand approved by the engineer in charge. |
| 120 | OD180775/2026-2027:Supply and fixing of 9W B22D LED Emergency Inverter Bulb (Cool Day Light/Crystal White).Rechargeable, Energy Efficient, Flicker-Free, Eye-Friendly. (Make: Philips or equivalent makeapproved by CPWD/KPWD/KSCADC) |
| 121 | OD180777/2026-2027:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 122 | OD184957/2026-2027:Supply, Installation, Testing and Commissioning of 20W LED tube set (4 feet length, plastic body) of reputed brand. With all necessary equipment. |
| 123 | Fire & Safety |
| 124 | OD177096/2026-2027:S/F DCP fire extinguisher (5Kg): supply and installation of 5kg Dry chemical power type (DCP) fire extinguishers having ISI mark along with mounting supports etc.as required. |
| 125 | OD177110/2026-2027:Supply and providing First Aid Box with first aid medicines and accessories. Color: Red & White, Size:11Inch * 13 Inch * 3 Inch (W x D x H). Made from galvanize Metal with 7 Way Processed Powder Coating for Long Lasting. Front Heavy Clear acrylic. 4 Partition for medicines organize with lock and 2 set of key. Top side handle for carry to any where and also Wall Mountable. |
| 126 | OD177123/2026-2027:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. |
| 127 | OD177141/2026-2027: Providing and Fixing of Electrical ISI<br>Grade Rubber Mat suitable for 440Volts<br>Switchboards. |
| 128 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 129 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 130 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 131 | OD183380/2026-2027:Supply and installation of SITC of True Online Double Conversion 10KVA 10kwONLINE UPS, three phase input & output. With Built in Isolation transformer atinput side from the UPS OEM. With open battery rack and interconnecting cables,O/p Unity PF Design (kVA=kW), Built in Phase Reversal Protection & Correction,capable to back up IT & Computer Peripheral, Small & Medium DC, Lighting,Transportation, Light Industry process automation, CNC Machine & VFD withpeak load with in 1/3 UPS capacity & with O/P ISO Trf, Medical Equipment withpeak load with in 1/3 UPS capacity & with O/P ISO Trf, Etc… THDI <5% @100%LOAD, IEC62040-1,2,3,4. SITC of SMF battery for Back Up time 120 Min. on fullload,12v100AHx 20 nos), UPS 3 years and Batteries warranty considered 2years. CE or equivalent, ups make Legrand-Numeric/ABB/GE, make of batteriesExide/Quanta, equivalent make approved by CPWD/KPWD/KSCADC |
| 132 | Air Conditioner |
| 133 | OD177161/2026-2027:Supply and installation of AC Stabilizer for 2-ton AC | Intelligent Time Delay System | Energy Efficient Design | Convenient LED Indicator | 2 Year Warranty | (Working Range 140-280 VAC). Initial Time Delay System. High and Low Voltage Cut Off. Advanced IC Technology Design. High Temperature Protection: (Approved make by CPWD/KPWD/KSCADC) |
| 134 | OD177167/2026-2027:Supply, Installation and commissioning of 2 Ton 5 Star Split Inverter Air Conditioner with ECHO MODE, TURBO COOL, ECO-FRIENDLYREFRIGERANT, COOLING CAPACITY (WATT)(MIN~MAX) - 6100 (2702~6357), COOLING CAPACITY (BTU/HR) - 20847(9219~21690), COOLING POWER INPUT (50% LOAD) (WATT) - 770, AIR FLOW VOLUME (WET CFM) - 790, NOISE LEVEL INDOOR /OUTDOOR DB - 52/58 dB, COMPRESSOR TYPE INVERTER ROTARY AND 100% COPPER and remote control with LCD display (MODEL - BLUE STAR IA524DNU or equivalent model approved by CPWD/KPWD/KSCADC) |
| 135 | Demolishing & Repairing of Existing Inventories/Devices |
| 136 | 1.59:Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. |
| 137 | OD183432/2026-2027:Labour charges for removing the existing conduit, wire, cable, LAN cable,Electrical inventories etc… and placing them on an appropriate place for furtheractions Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender