Communications and Information Technology Government Departments Closing in 7 days TDR #58435525

Bids Are invited for Lift Sh Providing Power Supply And Associated Work Fafadih Raipur

Issued by Government Departments · Raipur, Chhattisgarh
Tender Value
4.89 Lakhs
Estimated cost
Bid Submission
18 Nov 2026
7 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raipur → Chhattisgarh
EMD Exemption
Not Available
Quantity
333

Project Description

Bids Are invited for 4 Way 4 Plus 12 Double Door - Supplying And Fixing Of Following Ways Surface Recess Mounting Vertical Type 415 Volts Tpn Mcb Distribution Board Of Sheet Steel Dust Protected Duly Powder Painted Inclusive Of 200 Amps Tinned Copper Bus Bar Common Neutral Link Earth Bar Din Bar For Mounting Mcbs But Without Mcbs And Incomer As Required Note Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required , 2 Plus 12 Way Double Door - Supplying And Fixing Following Way Single Pole And Neutral Sheet Steel Mcb Distribution Board 240 Volts On Surface/ Recess Complete With Tinned Copper Bus Bar Neutral Bus Bar Earth Bar Din Bar Interconnections Powder Painted Including Earthing Etc As Required But Without Mcb/Rccb/Isolator , Single Pole - Supplying And Fixing 5 Amps To 32 Amps Rating 240/415 Volts C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , Triple Pole And Neutral - Supplying And Fixing 5 Amps To 32 Amps Rating 240/415 Volts C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , 240 Volts 25 Amps - Supplying And Fixing The Following Rating Double Pole Single Phase And Neutral 240 Volts Residual Current Circuit Breaker Rccb Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , 415 Volts 25 Amps - Supplying And Fixing Following Rating Four Pole Three Phase And Neutral 415 Volts Residual Current Circuit Breaker Rccb Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Requireda 25 Amps , Wire 3 X 25 Sq - Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Requireda 3 X 25 Sq Mm , 4 Foot Led Tube Rod 20 W Fitting - Supplying And Fixing Of 4Foot Led Tube Rod 20 W Fitting Complete Connection Testing Complete As Required , Steel Conduit - Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface/Recess Including Painting In Case Of Surface Conduit Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , Metal Switch Box For Housing - Supplying And Fixing A Suitable Metal Switch Box For Housing 2 Nos 5 A Pianotype Switches And 1 No 5 A 3Pin Socket Outlet Complete With Phenolic Laminated Sheet Connection Testing Complete As Required , Maintenance Free Chemical Earth Station - Supply Installation Testing And Commissioning Of Maintenance Free Chemical Earth Station As Per Latest Rdso Bsnl Specifications Consisting Of A Copper Bonded Steel Electrode Of 30 Mtrs Long 17 Mm Dia With Copper Bonded Thickness Of Minimum 250 Microns And Ul Listed And Marked 01 No B Earth Enhancing Compound Minimum 3035 Kg Of Rdso Bsnl Approved Brandsuplied In Sealed Bags Of Minimum 10 Kg Make Rdso Bsnl Approved C Providing And Weld Exothermic A Copper Bus Bar Of Minimum Size 6Mmx25mmx150mm On Top Of Earth Electroded Providing And Making Inspection Chamber Dmc Pit Cover Of Minimum Size Of 425 Mm X 250 Mm Etc Complete As Required , Copper Main Equi Potential Earth Busbar Meeb - Providing And Fixing Copper Main Equipotential Earth Busbar Meeb Of Minimum Size 6 Mm X 25 Mm X 300 Mm Fixing On Wall With Two No Suitable Insulator Ic Suitable Size Nut Bolt Spring Waser And Marking And Sign Writing As Per The Direction Of Engineer Incharge Etc Complete As Required At Site , 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground - Supplying And Laying 25 Mm X 5 Mm Copper Strip At 050 Metre Below Ground As Strip Earth Electrode Including Connection/ Terminating With Nut Bolt Spring Washer Etc As Required Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt And Spring Washer Spaced At 50Mm , 16 Sqmm. Copper Conductor - Supplying And Laying 16 Sqmm Copper Conductor Flexible Multistrand Unarmoured Pvc Insulated And Pvc Sheathed Copper Cable On Surface/Air I/C Suitable Size Of Lugs Nut Bolt Etc For Earth Connections Etc Complete As Reqd For Earthing Conductor , 4X4 Sqmm. Copper Conductor Multistrand Armoured Pvc Insulated And Pvc Sheathed Copper Cable - Supplying And Laying 4X4 Sqmm Copper Conductor Multistrand Armoured Pvc Insulated And Pvc Sheathed Copper Cable On Surface/Air I/C Suitable Size Of Lugs Nut Bolt Etccomplete As Required , Desmantling Of The Existing 8 Passenger Lift - Desmantling Of The Existing 8Passenger Lift Complete With Motor Guide Rail Lift Car Doors Channels And All Other Accessories And Tools And Plant Required To Dismantle The Lift And Keep The Dismantled Item At The Space Directed By The Engineer In Charge Complete As Required , Scaf Folding Fitting Inside The Lift Shaft - Making Scaffolding Fitting Inside The Lift Shaft On A Rental Basis For Execution Of All Work Required For Lift Installation Complete As Required , Making Colouring Work Painting - Making Colouring Work Painting By Distamber White Colour And Filling Of All Unused Holes Small Windows And Cracks With Cement Concrete And Putty Inside The Lift Shaft Complete As Required , Chipping Work - Making Chipping Work At The Top Floor Near The Lift Door For The Installation Of The Lift Controller/Db Complete As Required , Making A Window Of Size 800X800 - Making A Window Of Size 800X800 At The Top Left Corner Of The Front Wall With Suitable Framework Work Door And A Lockable Arrangement And Additionaly Providing A Movable Aluminium Staircase Complete As Required , Complete Door Barricading Of The Door Opening Of The Lift - Making A Complete Door Barricading Of The Door Opening Of The Lift Shaft With An Existing Plywood For The Entire Floor G+3 Complete As Required Plywood Will Be Provided At Auto T Ex Transporting To Be Done , 4.5 Kg Co2 Type Fire Extinguishers - Supply And Fixing Of 45 Kg Co2 Type Fire Extinguishers Isi Mark Complete With Mounting Hook As Requiredmake Isimarked , Bottom Fire Bucket Filled With Sand - Supplying And Fixing A Roundbottom Fire Bucket Filled With Sand Hung On A Wall In A Suitable Bracket As Required , Pvc Sheet Floor Number - Supplying And Fixing A Pvc Sheet Floor Numbermarking Sticker In Front Of The Opening Gate Of The Lift Of Suitable Size As Required , Pvc Sheet Exit Signboard - Supplying And Fixing A Pvc Sheet Exit Signboard With An Arrow On The Wall Complete As Required Size 1 Feet X 2 Feet , Making Additional Support - Providing And Making Additional Support With Cchannel /Angle Iron To The Machine/Motor Assembly Set Of The New Lift Complete Grouting Welding And Painting As Required Channel To Be Fixed As Per Direction Of Lift Company

BOQ

Sl. No. Item TitleItem Description
14 way 4 plus 12 Double doorSupplying and fixing of following ways surface recess mounting vertical type 415 volts TPN MCB distribution board of sheet steel dust protected duly powder painted inclusive of 200 amps tinned copper bus bar common neutral link earth bar din bar for mounting MCBs but without MCBs and incomer as required Note Vertical type MCB TPDB is normally used where 3 phase outlets are required
22 plus 12 way Double doorSupplying and fixing following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/ recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted including earthing etc as required But without MCB/RCCB/Isolator
3Single poleSupplying and fixing 5 amps to 32 amps rating 240/415 volts C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required
4Triple pole and neutralSupplying and fixing 5 amps to 32 amps rating 240/415 volts C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required
5240 volts 25 ampsSupplying and fixing the following rating double pole single phase and neutral 240 volts residual current circuit breaker RCCB having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections testing and commissioning etc as required
6415 volts 25 ampsSupplying and fixing following rating four pole three phase and neutral 415 volts residual current circuit breaker RCCB having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections testing and commissioning etc as requireda 25 amps
7Wire 3 x 25 sqSupplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as requireda 3 x 25 sq mm
84 foot LED Tube rod 20 W FittingSupplying and fixing of 4foot LED Tube rod 20 W Fitting complete connection testing complete as required
9Steel conduitSupplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required25 mm
10Metal switch box for housingSupplying and fixing a suitable Metal switch box for housing 2 nos 5 A pianotype switches and 1 no 5 A 3pin socket outlet complete with phenolic laminated sheet connection testing complete as required
11Maintenance free Chemical earth stationSupply Installation Testing and Commissioning of Maintenance free Chemical earth station as per latest RDSO BSNL specifications consisting of a Copper bonded steel Electrode of 30 Mtrs long 17 mm dia with copper bonded thickness of minimum 250 microns and UL listed and marked 01 No b Earth enhancing compound minimum 3035 Kg of RDSO BSNL approved brandsuplied in sealed bags of minimum 10 Kg Make RDSO BSNL approved c Providing and weld Exothermic a Copper bus bar of minimum size 6mmx25mmx150mm on top of earth electroded Providing and making inspection chamber DMC pit cover of minimum size of 425 mm x 250 mm etc complete as required
12Copper Main Equi potential earth busbar MEEBProviding and Fixing Copper Main Equipotential earth busbar MEEB of minimum size 6 mm x 25 mm x 300 mm fixing on wall with two no suitable insulator ic suitable size nut bolt spring waser and marking and sign writing as per the direction of Engineer incharge etc complete as required at site
1325 mm X 5 mm copper strip at 0.50 metre below groundSupplying and laying 25 mm X 5 mm copper strip at 050 metre below ground as strip earth electrode including connection/ terminating with nut bolt spring washer etc as required Jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm
1416 sqmm. copper conductorSupplying and laying 16 sqmm copper conductor flexible multistrand unarmoured pvc insulated and PVC sheathed copper cable on surface/air i/c suitable size of lugs nut bolt etc for earth connections etc complete as reqd for Earthing Conductor
154X4 sqmm. copper conductor multistrand armoured pvc insulated and PVC sheathed copper cableSupplying and laying 4X4 sqmm copper conductor multistrand armoured pvc insulated and PVC sheathed copper cable on surface/air i/c suitable size of lugs nut bolt etccomplete as required
16Desmantling of the existing 8 passenger liftDesmantling of the existing 8passenger lift complete with Motor guide rail lift car doors channels and all other accessories and tools and plant required to dismantle the lift and keep the dismantled item at the space directed by the engineer in charge complete as required
17Scaf folding fitting inside the lift shaftMaking Scaffolding fitting inside the lift shaft on a rental basis for execution of all work required for lift installation complete as required
18Making colouring work paintingMaking colouring work painting by distamber white colour and filling of all unused holes small windows and cracks with cement concrete and putty inside the lift shaft complete as required
19chipping workMaking chipping work at the top floor near the lift door for the installation of the lift controller/DB complete as required
20Making a window of size 800X800Making a window of size 800X800 at the top left corner of the front wall with suitable framework work door and a lockable arrangement and additionaly providing a movable aluminium staircase complete as required
21complete door barricading of the door opening of the liftMaking a complete door barricading of the door opening of the lift shaft with an existing plywood for the entire floor G+3 complete as required Plywood will be provided at Auto T Ex transporting to be done
224.5 KG CO2 type fire extinguishersSupply and fixing of 45 KG CO2 type fire extinguishers ISI mark complete with mounting hook as requiredMake ISImarked
23bottom fire bucket filled with sandSupplying and fixing a roundbottom fire bucket filled with sand hung on a wall in a suitable bracket as required
24PVC sheet floor numberSupplying and fixing a PVC sheet floor numbermarking sticker in front of the opening gate of the lift of suitable size as required
25PVC sheet EXIT signboardSupplying and fixing a PVC sheet EXIT signboard with an arrow on the wall complete as required Size 1 feet x 2 feet
26making additional supportProviding and making additional support with Cchannel /angle iron to the Machine/motor assembly set of the new lift complete grouting welding and painting as required Channel to be fixed as per direction of lift company

AI Tender Summary

OUR REF NO 58435525
AUTHORITY Government Departments
TENDER VALUE 4.89 Lakhs
LAST DATE 18-11-2026
Authority
Authority Name Department Of Telecommunications
Work Description Bids Are invited for 4 Way 4 Plus 12 Double Door - Supplying And Fixing Of Following Ways Surface Recess Mounting Vertical Type 415 Volts Tpn Mcb Distribution Board Of Sheet Steel Dust Protected Duly Powder Painted Inclusive Of 200 Amps Tinned Copper Bus Bar Common Neutral Link Earth Bar Din Bar For Mounting Mcbs But Without Mcbs And Incomer As Required Note Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required , 2 Plus 12 Way Double Door - Supplying And Fixing Following Way Single Pole And Neutral Sheet Steel Mcb Distribution Board 240 Volts On Surface/ Recess Complete With Tinned Copper Bus Bar Neutral Bus Bar Earth Bar Din Bar Interconnections Powder Painted Including Earthing Etc As Required But Without Mcb/Rccb/Isolator , Single Pole - Supplying And Fixing 5 Amps To 32 Amps Rating 240/415 Volts C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , Triple Pole And Neutral - Supplying And Fixing 5 Amps To 32 Amps Rating 240/415 Volts C Curve Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , 240 Volts 25 Amps - Supplying And Fixing The Following Rating Double Pole Single Phase And Neutral 240 Volts Residual Current Circuit Breaker Rccb Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required , 415 Volts 25 Amps - Supplying And Fixing Following Rating Four Pole Three Phase And Neutral 415 Volts Residual Current Circuit Breaker Rccb Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Requireda 25 Amps , Wire 3 X 25 Sq - Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Requireda 3 X 25 Sq Mm , 4 Foot Led Tube Rod 20 W Fitting - Supplying And Fixing Of 4Foot Led Tube Rod 20 W Fitting Complete Connection Testing Complete As Required , Steel Conduit - Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface/Recess Including Painting In Case Of Surface Conduit Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , Metal Switch Box For Housing - Supplying And Fixing A Suitable Metal Switch Box For Housing 2 Nos 5 A Pianotype Switches And 1 No 5 A 3Pin Socket Outlet Complete With Phenolic Laminated Sheet Connection Testing Complete As Required , Maintenance Free Chemical Earth Station - Supply Installation Testing And Commissioning Of Maintenance Free Chemical Earth Station As Per Latest Rdso Bsnl Specifications Consisting Of A Copper Bonded Steel Electrode Of 30 Mtrs Long 17 Mm Dia With Copper Bonded Thickness Of Minimum 250 Microns And Ul Listed And Marked 01 No B Earth Enhancing Compound Minimum 3035 Kg Of Rdso Bsnl Approved Brandsuplied In Sealed Bags Of Minimum 10 Kg Make Rdso Bsnl Approved C Providing And Weld Exothermic A Copper Bus Bar Of Minimum Size 6Mmx25mmx150mm On Top Of Earth Electroded Providing And Making Inspection Chamber Dmc Pit Cover Of Minimum Size Of 425 Mm X 250 Mm Etc Complete As Required , Copper Main Equi Potential Earth Busbar Meeb - Providing And Fixing Copper Main Equipotential Earth Busbar Meeb Of Minimum Size 6 Mm X 25 Mm X 300 Mm Fixing On Wall With Two No Suitable Insulator Ic Suitable Size Nut Bolt Spring Waser And Marking And Sign Writing As Per The Direction Of Engineer Incharge Etc Complete As Required At Site , 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground - Supplying And Laying 25 Mm X 5 Mm Copper Strip At 050 Metre Below Ground As Strip Earth Electrode Including Connection/ Terminating With Nut Bolt Spring Washer Etc As Required Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt And Spring Washer Spaced At 50Mm , 16 Sqmm. Copper Conductor - Supplying And Laying 16 Sqmm Copper Conductor Flexible Multistrand Unarmoured Pvc Insulated And Pvc Sheathed Copper Cable On Surface/Air I/C Suitable Size Of Lugs Nut Bolt Etc For Earth Connections Etc Complete As Reqd For Earthing Conductor , 4X4 Sqmm. Copper Conductor Multistrand Armoured Pvc Insulated And Pvc Sheathed Copper Cable - Supplying And Laying 4X4 Sqmm Copper Conductor Multistrand Armoured Pvc Insulated And Pvc Sheathed Copper Cable On Surface/Air I/C Suitable Size Of Lugs Nut Bolt Etccomplete As Required , Desmantling Of The Existing 8 Passenger Lift - Desmantling Of The Existing 8Passenger Lift Complete With Motor Guide Rail Lift Car Doors Channels And All Other Accessories And Tools And Plant Required To Dismantle The Lift And Keep The Dismantled Item At The Space Directed By The Engineer In Charge Complete As Required , Scaf Folding Fitting Inside The Lift Shaft - Making Scaffolding Fitting Inside The Lift Shaft On A Rental Basis For Execution Of All Work Required For Lift Installation Complete As Required , Making Colouring Work Painting - Making Colouring Work Painting By Distamber White Colour And Filling Of All Unused Holes Small Windows And Cracks With Cement Concrete And Putty Inside The Lift Shaft Complete As Required , Chipping Work - Making Chipping Work At The Top Floor Near The Lift Door For The Installation Of The Lift Controller/Db Complete As Required , Making A Window Of Size 800X800 - Making A Window Of Size 800X800 At The Top Left Corner Of The Front Wall With Suitable Framework Work Door And A Lockable Arrangement And Additionaly Providing A Movable Aluminium Staircase Complete As Required , Complete Door Barricading Of The Door Opening Of The Lift - Making A Complete Door Barricading Of The Door Opening Of The Lift Shaft With An Existing Plywood For The Entire Floor G+3 Complete As Required Plywood Will Be Provided At Auto T Ex Transporting To Be Done , 4.5 Kg Co2 Type Fire Extinguishers - Supply And Fixing Of 45 Kg Co2 Type Fire Extinguishers Isi Mark Complete With Mounting Hook As Requiredmake Isimarked , Bottom Fire Bucket Filled With Sand - Supplying And Fixing A Roundbottom Fire Bucket Filled With Sand Hung On A Wall In A Suitable Bracket As Required , Pvc Sheet Floor Number - Supplying And Fixing A Pvc Sheet Floor Numbermarking Sticker In Front Of The Opening Gate Of The Lift Of Suitable Size As Required , Pvc Sheet Exit Signboard - Supplying And Fixing A Pvc Sheet Exit Signboard With An Arrow On The Wall Complete As Required Size 1 Feet X 2 Feet , Making Additional Support - Providing And Making Additional Support With Cchannel /Angle Iron To The Machine/Motor Assembly Set Of The New Lift Complete Grouting Welding And Painting As Required Channel To Be Fixed As Per Direction Of Lift Company
Basic Detail
Tender No GEM/2026/B/8253333
Bidding Type Tender
Location
City Raipur
State Chhattisgarh
Key Dates
Publish Date 07 Nov 2026
Submission Date 18 Nov 2026
Open Date 19 Nov 2026
Finance
Tender Value 4.89 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
9ad75664-730e-4655-8c9f-7fe8e0bd2312.pdf
report_2026-11-07-13-12-01_3d38d78ac042c09c62d77be9ae3b1733.pdf
10141795_Boq_1.xlsx
atc_8e5ee271-2aae-4f58-8e141794038108711_EEEBSNLRYP.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

9ad75664-730e-4655-8c9f-7fe8e0bd2312.pdf

pdf

report_2026-11-07-13-12-01_3d38d78ac042c09c62d77be9ae3b1733.pdf

xlsx

10141795_Boq_1.xlsx

pdf

atc_8e5ee271-2aae-4f58-8e141794038108711_EEEBSNLRYP.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender