Tender For Operation And Maintenance Of 2 Nos. Of Cwss In Virudhunagar District Including Repair And Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 19 B)
Tender Overview
Project Description
Tender for Operation And Maintenance Of 2 Nos. Of Cwss In Virudhunagar District Including Repair And Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 19 B)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Nov-2026 | Salient Details and Earmarked Quantity | Other | 07-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY EARMARKED QUANTITY OF WATER NOTED AGAINST 2 Nos of CWSS IN VIRUDHUNAGAR DISTRICT BY CARRYING OUT ALL THE NECESSARY WORKS SUCH AS PUMPING, ATTENDING TO LEAK AND BURST, ATTENDING TO ELECTRICAL AND MECHANICAL REPAIR WORKS, PROVIDING DISINFECTION, PREVENTIVE MAINTENANCE OF ALL INSTALLATIONS, SUMP CLEANING AND DELIVERANCE OF EARMARKED QUANTITY OF WATER TO THE BENEFICIARIES AS PER SCHEDULE AND STANDARD OPERATING PROCEDURES AND AS DIRECTED BY THE TWAD BOARD OFFICERS FOR the period from 01.01.2027 to 31.03.2029. |
| 2 | Operation and maintenance of the CWSS to 755 Rural habitations in Virudhunagar District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 |
| 3 | Operation and maintenance of the CWSS to Thulukkankuruchi and 4 other habitations in Vembakottai union of Virudhunagar District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 |
| 4 | Total Basic Value |
| 5 | Add GST @18% on Basic Value |
| 6 | 2.0 For the year 2026 - 2027 (From 01.01.2027 to 31.03.2027) |
| 7 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 17.13 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers. Totally 1541.70 ML (17.13 X 90) |
| 8 | Attending Burst in the PVC pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 9 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 10 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 11 | 50mm PVC 6 KSC |
| 12 | 63mm PVC 4 KSC |
| 13 | 75mm PVC 4 KSC |
| 14 | 90mm PVC 4 KSC |
| 15 | 110mm PVC 4 KSC |
| 16 | 140 mm PVC 4 KSC |
| 17 | 160 mm PVC 4 KSC |
| 18 | 200 mm PVC 4 KSC |
| 19 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 20 | 50mm PVC 6KSC |
| 21 | 63mm PVC 4KSC |
| 22 | 75mm PVC 4KSC |
| 23 | 90mm PVC 4 KSC |
| 24 | 110mm PVC 4KSC |
| 25 | 140mm PVC 4KSC |
| 26 | 160mm PVC 4KSC |
| 27 | 200mm PVC 4KSC |
| 28 | 50 mm PVC Coupler Fabricated 6 KSC |
| 29 | 63 mm PVC Coupler Fabricated 4 KSC |
| 30 | 75 mm PVC Coupler Fabricated 4 KSC |
| 31 | 90 mm PVC Coupler Fabricated 4 KSC |
| 32 | 110 mm PVC Coupler Fabricated 4 KSC |
| 33 | 140 mm PVC Coupler Fabricated 4 KSC |
| 34 | 160 mm PVC Coupler Fabricated 4 KSC |
| 35 | 200 mm PVC Coupler Fabricated 4 KSC |
| 36 | Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II - For DI Pipes |
| 37 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 38 | Dewatering using 7.5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 39 | 600 mm DI K7 Pipe |
| 40 | 400 mm DI K7 Pipe |
| 41 | 350 mm DI K7 Pipe |
| 42 | 300 mm DI K7 Pipe |
| 43 | 250 mm DI K7 Pipe |
| 44 | 200 mm DI K7 Pipe |
| 45 | Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 46 | 600 mm DI K7 Pipe |
| 47 | 400 mm DI K7 Pipe |
| 48 | 350 mm DI K7 Pipe |
| 49 | 300 mm DI K7 Pipe |
| 50 | 250 mm DI K7 Pipe |
| 51 | 200 mm DI K7 Pipe |
| 52 | Supply and delivery of Lead wool for Leak work DI pipeline including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 53 | 600 mm DI K7 Pipe |
| 54 | 400 mm DI K7 Pipe |
| 55 | 350 mm DI K7 Pipe |
| 56 | 300 mm DI K7 Pipe |
| 57 | 250 mm DI K7 Pipe |
| 58 | 200 mm DI K7 Pipe |
| 59 | Refilling with excavated soil (other than sand) complying with standard specification complete and as directed by the TWAD Board officers. |
| 60 | Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 61 | 0.5 HP |
| 62 | 1.5 HP |
| 63 | 7.5 HP |
| 64 | 10 HP |
| 65 | 12.5 HP |
| 66 | 15 HP |
| 67 | 30 HP |
| 68 | 35 HP |
| 69 | Rewinding of motor and repair works to Centifugal HSC Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers. |
| 70 | 40 HP |
| 71 | 50 HP |
| 72 | 100 HP |
| 73 | 120 HP |
| 74 | Rewinding of motor and repair works to Vertical Turbine Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers -50 Hp |
| 75 | Repair and reconditioning works to HSC centrifugal Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers. |
| 76 | 30 HP |
| 77 | 40 HP |
| 78 | 50 HP |
| 79 | 100 HP |
| 80 | 120 HP |
| 81 | Repair and reconditioning works to Vertical Turbine Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers- 50 HP |
| 82 | Attending Repair, Rectification and reconditioning of CI Sluice valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 83 | 300 mm CI Sluice valve |
| 84 | 250 mm CI Sluice valve |
| 85 | 150 mm CI Sluice valve |
| 86 | 100 mm CI Sluice valve |
| 87 | 65 mm CI Sluice valve |
| 88 | 50 mm CI Sluice valve |
| 89 | Attending Repair, Rectification and reconditioning of CI non return valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 90 | 300 mm CI NRV valve |
| 91 | 250 mm CI NRV valve |
| 92 | 150 mm CI NRV valve |
| 93 | 100 mm CI NRV valve |
| 94 | 65 mm CI NRV valve |
| 95 | 50 mm CI NRV valve |
| 96 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 97 | 40mm CI Double Air valve |
| 98 | 50mm CI Double Air valve |
| 99 | 80mm CI Double Air valve |
| 100 | 100mm DI Single Champer Air release valve |
| 101 | 150 mm DI Single Champer Air release valve Attending cable fault by replacing the cable |
| 102 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 103 | 3 core 10 Sq. mm aluminium cable |
| 104 | 3 core 16 Sq. mm aluminium cable |
| 105 | 3 core 25 Sq. mm aluminium cable |
| 106 | 3 core 35 Sq. mm aluminium cable |
| 107 | 3 core 50 Sq. mm aluminium cable |
| 108 | 3 core 70 Sq. mm aluminium cable |
| 109 | 3 core 120 Sq. mm aluminium cable |
| 110 | 3 core 185 Sq. mm aluminium cable |
| 111 | 3 core 400 Sq. mm aluminium cable |
| 112 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 113 | 3 core 10 Sq. mm aluminium cable |
| 114 | 3 core 16 Sq. mm aluminium cable |
| 115 | 3 core 25 Sq. mm aluminium cable |
| 116 | 3 core 35 Sq. mm aluminium cable |
| 117 | 3 core 50 Sq. mm aluminium cable |
| 118 | 3 core 70 Sq. mm aluminium cable |
| 119 | 3 core 120 Sq. mm aluminium cable |
| 120 | 3 core 185 Sq. mm aluminium cable |
| 121 | 3 core 400 Sq. mm aluminium cable |
| 122 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 123 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 124 | Supply and delivery of 12 Amps\440V Electro magnetic Contactors |
| 125 | Supply and delivery of 18 Amps\440V Electro magnetic Contactors |
| 126 | Supply and delivery of 22 Amps\440V Electro magnetic Contactors |
| 127 | Supply and delivery of 25 Amps\440V Electro magnetic Contactors |
| 128 | Supply and delivery of 32 Amps\440V Electro magnetic Contactors |
| 129 | Supply and delivery of 40 Amps\440V Electro magnetic Contactors |
| 130 | Supply and delivery of 70 Amps\440V Electro magnetic Contactors |
| 131 | Supply and delivery of 80 Amps\440V Electro magnetic Contactors |
| 132 | Supply and delivery of 120 Amps\440V Electro magnetic Contactors |
| 133 | Supply and delivery of 250 Amps\440V Electro magnetic Contactors |
| 134 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 135 | Upto 5A |
| 136 | Upto 5A - 10A |
| 137 | Upto 10A - 20A |
| 138 | Upto 30A - 50A |
| 139 | Upto 75A - 110A |
| 140 | Upto 110A - 150A |
| 141 | Upto 150A - 200A |
| 142 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 143 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 144 | Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers |
| 145 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)etc., complete and as directed by TWAD Board Officers |
| 146 | 0.5 HPStarter |
| 147 | 1 HPStarter |
| 148 | 1.5 HP Starter |
| 149 | 2 HP Starter |
| 150 | 3 HP Starter |
| 151 | 5 HP Starter |
| 152 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches,wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 153 | 7.5 HP Starter |
| 154 | 10 HP Starter |
| 155 | 12.5 HP Starter |
| 156 | 15 HP Starter |
| 157 | FULLY AUTOMATIC AIR BREAK STAR DELTA STARTER WITH SINGLE PHASE PREVENTOR WITH AMMETER CONFIRMING TO IS 13947, IEC 60947-1 WITH AUTO RESTART FACILITY FOR PUMP HOUSES WHERE PANEL BOARDS ARE AVAILABLESupply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 158 | 30 HP Starter |
| 159 | Supply and delivery of following Range AMPS 3 pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 160 | 32-100 Amps 3 Pole MCCB Switch |
| 161 | Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 162 | 160 Amps MCCB Switch |
| 163 | 200 Amps MCCB Switch |
| 164 | 250 Amps MCCB Switch |
| 165 | 320 Amps MCCB Switch |
| 166 | 400 Amps MCCB Switch |
| 167 | Supply and delivery of the following gate valves etc., complete and as directed by TWAD Board Officers at the site of work to carryout the general maintenace works etc., complete and as directed by TWAD Board Officers |
| 168 | 50 mm Gate valve |
| 169 | 65 mm Gate valve |
| 170 | 80 mm Gate valve |
| 171 | Attending Major Repair works for following KVA/443V Transformer For 400 KVA |
| 172 | Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 173 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 174 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 175 | Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 176 | Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 177 | Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 178 | Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 179 | Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 180 | Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 181 | Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 182 | Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 183 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 184 | Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 185 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 186 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 187 | Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 188 | Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers For 315 KVA |
| 189 | Labour Charges for dismantling of 315 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 190 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 191 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 192 | Supply and delievery of 3 phase insulation material to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 193 | Supply and delievery of new transformer oil to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 194 | Supply and delievery of 11KV HV bushing with Metal parts to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 195 | Supply and delievery of 433V LV bushing copper rod to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 196 | Supply and delievery of silica gel breather to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 197 | Supply and delievery of capillary type thermometer including accessories to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 198 | Supply and delievery of gasket & oil seals to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 199 | Supply and delievery of paint to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 200 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 315 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 201 | Charges for Transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 202 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 203 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 204 | Charges for Re erection of 315 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 205 | Conveyance charges for transformers unit from Site to work shop site and work shop site to site completion of rectification works etc complete as directed by Twad Board officers For 250 KVA |
| 206 | Labour Charges for dismantling of 250 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 207 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 208 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 209 | Supply and delievery of 3 phase insulation material to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 210 | Supply and delievery of new transformer oil to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 211 | Supply and delievery of 11KV HV bushing with Metal parts to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 212 | Supply and delievery of 433V LV bushing copper rod to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 213 | Supply and delievery of silica gel breather to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 214 | Supply and delievery of capillary type thermometer including accessories to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 215 | Supply and delievery of gasket & oil seals to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 216 | Supply and delievery of paint to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 217 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 250 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 218 | Charges for Transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 219 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 220 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 221 | Charges for Re erection of 250 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 222 | Conveyance charges for transformers unit from site to work shop site and work shop to site completion of rectification works etc complete as directed by Twad Board officers |
| 223 | Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers |
| 224 | 0.15 capacity of sump |
| 225 | 0.20 capacity of sump |
| 226 | 0.25 capacity of sump |
| 227 | 0.30 capacity of sump |
| 228 | 0.35 capacity of sump |
| 229 | 0.40 capacity of sump |
| 230 | 0.45 capacity of sump |
| 231 | 0.50 capacity of sump |
| 232 | 0.55 capacity of sump |
| 233 | 0.60 capacity of sump |
| 234 | 0.65 capacity of sump |
| 235 | 0.70 capacity of sump |
| 236 | 0.75 capacity of sump |
| 237 | 0.80 capacity of sump |
| 238 | 0.85 capacity of sump |
| 239 | 0.90 capacity of sump |
| 240 | 0.95 capacity of sump |
| 241 | 1.00 capacity of sump |
| 242 | 1.05 capacity of sump |
| 243 | 1.15 capacity of sump |
| 244 | 1.20 capacity of sump |
| 245 | 1.30 capacity of sump |
| 246 | 1.55 capacity of sump |
| 247 | 1.65 capacity of sump |
| 248 | 1.75 capacity of sump |
| 249 | 1.85 capacity of sump |
| 250 | 1.95 capacity of sump |
| 251 | 2.05 capacity of sump |
| 252 | 2.35 capacity of sump |
| 253 | 2.45 capacity of sump |
| 254 | 2.50 capacity of sump |
| 255 | 2.55 capacity of sump |
| 256 | 2.85 capacity of sump |
| 257 | 3.10 capacity of sump |
| 258 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers |
| 259 | Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. |
| 260 | Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers. |
| 261 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total I -2026-2027 For the year 2027 - 2028(From 01.04.2027 to 31.03.2028) |
| 262 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 17.13 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers. Totally 6252.45 ML (17.13 X 366) |
| 263 | Attending Burst in the PVC pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 264 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 265 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 266 | 50mm PVC 6 KSC |
| 267 | 63mm PVC 4 KSC |
| 268 | 75mm PVC 4 KSC |
| 269 | 90mm PVC 4 KSC |
| 270 | 110mm PVC 4 KSC |
| 271 | 140 mm PVC 4 KSC |
| 272 | 160 mm PVC 4 KSC |
| 273 | 200 mm PVC 4 KSC |
| 274 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 275 | 50mm PVC 6KSC |
| 276 | 63mm PVC 4KSC |
| 277 | 75mm PVC 4KSC |
| 278 | 90mm PVC 4 KSC |
| 279 | 110mm PVC 4KSC |
| 280 | 140mm PVC 4KSC |
| 281 | 160mm PVC 4KSC |
| 282 | 200mm PVC 4KSC |
| 283 | 50 mm PVC Coupler Fabricated 6 KSC |
| 284 | 63 mm PVC Coupler Fabricated 4 KSC |
| 285 | 75 mm PVC Coupler Fabricated 4 KSC |
| 286 | 90 mm PVC Coupler Fabricated 4 KSC |
| 287 | 110 mm PVC Coupler Fabricated 4 KSC |
| 288 | 140 mm PVC Coupler Fabricated 4 KSC |
| 289 | 160 mm PVC Coupler Fabricated 4 KSC |
| 290 | 200 mm PVC Coupler Fabricated 4 KSC |
| 291 | Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II - For DI Pipes |
| 292 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 293 | Dewatering using 7.5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 294 | 600 mm DI K7 Pipe |
| 295 | 400 mm DI K7 Pipe |
| 296 | 350 mm DI K7 Pipe |
| 297 | 300 mm DI K7 Pipe |
| 298 | 250 mm DI K7 Pipe |
| 299 | 200 mm DI K7 Pipe |
| 300 | Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 301 | 600 mm DI K7 Pipe |
| 302 | 400 mm DI K7 Pipe |
| 303 | 350 mm DI K7 Pipe |
| 304 | 300 mm DI K7 Pipe |
| 305 | 250 mm DI K7 Pipe |
| 306 | 200 mm DI K7 Pipe |
| 307 | Supply and delivery of Lead wool for Leak work DI pipeline including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 308 | 600 mm DI K7 Pipe |
| 309 | 400 mm DI K7 Pipe |
| 310 | 350 mm DI K7 Pipe |
| 311 | 300 mm DI K7 Pipe |
| 312 | 250 mm DI K7 Pipe |
| 313 | 200 mm DI K7 Pipe |
| 314 | Refilling with excavated soil (other than sand) complying with standard specification complete and as directed by the TWAD Board officers. |
| 315 | Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 316 | 0.5 HP |
| 317 | 1.5 HP |
| 318 | 7.5 HP |
| 319 | 10 HP |
| 320 | 12.5 HP |
| 321 | 15 HP |
| 322 | 30 HP |
| 323 | 35 HP |
| 324 | Rewinding of motor and repair works to Centifugal HSC Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers. |
| 325 | 40 HP |
| 326 | 50 HP |
| 327 | 100 HP |
| 328 | 120 HP |
| 329 | Rewinding of motor and repair works to Vertical Turbine Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers -50 Hp |
| 330 | Repair and reconditioning works to HSC centrifugal Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers. |
| 331 | 30 HP |
| 332 | 40 HP |
| 333 | 50 HP |
| 334 | 100 HP |
| 335 | 120 HP |
| 336 | Repair and reconditioning works to Vertical Turbine Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers- 50 HP |
| 337 | Attending Repair, Rectification and reconditioning of CI Sluice valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 338 | 300 mm CI Sluice valve |
| 339 | 250 mm CI Sluice valve |
| 340 | 150 mm CI Sluice valve |
| 341 | 100 mm CI Sluice valve |
| 342 | 65 mm CI Sluice valve |
| 343 | 50 mm CI Sluice valve |
| 344 | Attending Repair, Rectification and reconditioning of CI non return valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 345 | 300 mm CI NRV valve |
| 346 | 250 mm CI NRV valve |
| 347 | 150 mm CI NRV valve |
| 348 | 100 mm CI NRV valve |
| 349 | 65 mm CI NRV valve |
| 350 | 50 mm CI NRV valve |
| 351 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 352 | 40mm CI Double Air valve |
| 353 | 50mm CI Double Air valve |
| 354 | 80mm CI Double Air valve |
| 355 | 100mm DI Single Champer Air release valve |
| 356 | 150 mm DI Single Champer Air release valve Attending cable fault by replacing the cable |
| 357 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 358 | 3 core 10 Sq. mm aluminium cable |
| 359 | 3 core 16 Sq. mm aluminium cable |
| 360 | 3 core 25 Sq. mm aluminium cable |
| 361 | 3 core 35 Sq. mm aluminium cable |
| 362 | 3 core 50 Sq. mm aluminium cable |
| 363 | 3 core 70 Sq. mm aluminium cable |
| 364 | 3 core 120 Sq. mm aluminium cable |
| 365 | 3 core 185 Sq. mm aluminium cable |
| 366 | 3 core 400 Sq. mm aluminium cable |
| 367 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 368 | 3 core 10 Sq. mm aluminium cable |
| 369 | 3 core 16 Sq. mm aluminium cable |
| 370 | 3 core 25 Sq. mm aluminium cable |
| 371 | 3 core 35 Sq. mm aluminium cable |
| 372 | 3 core 50 Sq. mm aluminium cable |
| 373 | 3 core 70 Sq. mm aluminium cable |
| 374 | 3 core 120 Sq. mm aluminium cable |
| 375 | 3 core 185 Sq. mm aluminium cable |
| 376 | 3 core 400 Sq. mm aluminium cable |
| 377 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 378 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 379 | Supply and delivery of 12 Amps\440V Electro magnetic Contactors |
| 380 | Supply and delivery of 18 Amps\440V Electro magnetic Contactors |
| 381 | Supply and delivery of 22 Amps\440V Electro magnetic Contactors |
| 382 | Supply and delivery of 25 Amps\440V Electro magnetic Contactors |
| 383 | Supply and delivery of 32 Amps\440V Electro magnetic Contactors |
| 384 | Supply and delivery of 40 Amps\440V Electro magnetic Contactors |
| 385 | Supply and delivery of 70 Amps\440V Electro magnetic Contactors |
| 386 | Supply and delivery of 80 Amps\440V Electro magnetic Contactors |
| 387 | Supply and delivery of 120 Amps\440V Electro magnetic Contactors |
| 388 | Supply and delivery of 250 Amps\440V Electro magnetic Contactors |
| 389 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 390 | Upto 5A |
| 391 | Upto 5A - 10A |
| 392 | Upto 10A - 20A |
| 393 | Upto 30A - 50A |
| 394 | Upto 75A - 110A |
| 395 | Upto 110A - 150A |
| 396 | Upto 150A - 200A |
| 397 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 398 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 399 | Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers |
| 400 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)etc., complete and as directed by TWAD Board Officers |
| 401 | 0.5 HPStarter |
| 402 | 1 HPStarter |
| 403 | 1.5 HP Starter |
| 404 | 2 HP Starter |
| 405 | 3 HP Starter |
| 406 | 5 HP Starter |
| 407 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches,wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 408 | 7.5 HP Starter |
| 409 | 10 HP Starter |
| 410 | 12.5 HP Starter |
| 411 | 15 HP Starter |
| 412 | FULLY AUTOMATIC AIR BREAK STAR DELTA STARTER WITH SINGLE PHASE PREVENTOR WITH AMMETER CONFIRMING TO IS 13947, IEC 60947-1 WITH AUTO RESTART FACILITY FOR PUMP HOUSES WHERE PANEL BOARDS ARE AVAILABLESupply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 413 | 30 HP Starter |
| 414 | Supply and delivery of following Range AMPS 3 pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 415 | 32-100 Amps 3 Pole MCCB Switch |
| 416 | Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 417 | 160 Amps MCCB Switch |
| 418 | 200 Amps MCCB Switch |
| 419 | 250 Amps MCCB Switch |
| 420 | 320 Amps MCCB Switch |
| 421 | 400 Amps MCCB Switch |
| 422 | Supply and delivery of the following gate valves etc., complete and as directed by TWAD Board Officers at the site of work to carryout the general maintenace works etc., complete and as directed by TWAD Board Officers |
| 423 | 50 mm Gate valve |
| 424 | 65 mm Gate valve |
| 425 | 80 mm Gate valve |
| 426 | Attending Major Repair works for following KVA/443V Transformer For 400 KVA |
| 427 | Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 428 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 429 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 430 | Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 431 | Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 432 | Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 433 | Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 434 | Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 435 | Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 436 | Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 437 | Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 438 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 439 | Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 440 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 441 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 442 | Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 443 | Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers For 315 KVA |
| 444 | Labour Charges for dismantling of 315 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 445 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 446 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 447 | Supply and delievery of 3 phase insulation material to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 448 | Supply and delievery of new transformer oil to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 449 | Supply and delievery of 11KV HV bushing with Metal parts to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 450 | Supply and delievery of 433V LV bushing copper rod to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 451 | Supply and delievery of silica gel breather to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 452 | Supply and delievery of capillary type thermometer including accessories to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 453 | Supply and delievery of gasket & oil seals to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 454 | Supply and delievery of paint to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 455 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 315 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 456 | Charges for Transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 457 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 458 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 459 | Charges for Re erection of 315 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 460 | Conveyance charges for transformers unit from Site to work shop site and work shop site to site completion of rectification works etc complete as directed by Twad Board officers For 250 KVA |
| 461 | Labour Charges for dismantling of 250 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 462 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 463 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 464 | Supply and delievery of 3 phase insulation material to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 465 | Supply and delievery of new transformer oil to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 466 | Supply and delievery of 11KV HV bushing with Metal parts to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 467 | Supply and delievery of 433V LV bushing copper rod to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 468 | Supply and delievery of silica gel breather to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 469 | Supply and delievery of capillary type thermometer including accessories to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 470 | Supply and delievery of gasket & oil seals to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 471 | Supply and delievery of paint to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 472 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 250 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 473 | Charges for Transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 474 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 475 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 476 | Charges for Re erection of 250 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 477 | Conveyance charges for transformers unit from site to work shop site and work shop to site completion of rectification works etc complete as directed by Twad Board officers |
| 478 | Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers |
| 479 | 0.15 capacity of sump |
| 480 | 0.20 capacity of sump |
| 481 | 0.25 capacity of sump |
| 482 | 0.30 capacity of sump |
| 483 | 0.35 capacity of sump |
| 484 | 0.40 capacity of sump |
| 485 | 0.45 capacity of sump |
| 486 | 0.50 capacity of sump |
| 487 | 0.55 capacity of sump |
| 488 | 0.60 capacity of sump |
| 489 | 0.65 capacity of sump |
| 490 | 0.70 capacity of sump |
| 491 | 0.75 capacity of sump |
| 492 | 0.80 capacity of sump |
| 493 | 0.85 capacity of sump |
| 494 | 0.90 capacity of sump |
| 495 | 0.95 capacity of sump |
| 496 | 1.00 capacity of sump |
| 497 | 1.05 capacity of sump |
| 498 | 1.15 capacity of sump |
| 499 | 1.20 capacity of sump |
| 500 | 1.30 capacity of sump |
| 501 | 1.55 capacity of sump |
| 502 | 1.65 capacity of sump |
| 503 | 1.75 capacity of sump |
| 504 | 1.85 capacity of sump |
| 505 | 1.95 capacity of sump |
| 506 | 2.05 capacity of sump |
| 507 | 2.35 capacity of sump |
| 508 | 2.45 capacity of sump |
| 509 | 2.50 capacity of sump |
| 510 | 2.55 capacity of sump |
| 511 | 2.85 capacity of sump |
| 512 | 3.10 capacity of sump |
| 513 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers |
| 514 | Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. |
| 515 | Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers. |
| 516 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total II 2027-2028 For the year 2028 - 2029(From 01.04.2028 to 31.03.2029) |
| 517 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 17.13 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers. Totally 6252.45 ML (17.13 X 365) |
| 518 | Attending Burst in the PVC pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 519 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 520 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 521 | 50mm PVC 6 KSC |
| 522 | 63mm PVC 4 KSC |
| 523 | 75mm PVC 4 KSC |
| 524 | 90mm PVC 4 KSC |
| 525 | 110mm PVC 4 KSC |
| 526 | 140 mm PVC 4 KSC |
| 527 | 160 mm PVC 4 KSC |
| 528 | 200 mm PVC 4 KSC |
| 529 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 530 | 50mm PVC 6KSC |
| 531 | 63mm PVC 4KSC |
| 532 | 75mm PVC 4KSC |
| 533 | 90mm PVC 4 KSC |
| 534 | 110mm PVC 4KSC |
| 535 | 140mm PVC 4KSC |
| 536 | 160mm PVC 4KSC |
| 537 | 200mm PVC 4KSC |
| 538 | 50 mm PVC Coupler Fabricated 6 KSC |
| 539 | 63 mm PVC Coupler Fabricated 4 KSC |
| 540 | 75 mm PVC Coupler Fabricated 4 KSC |
| 541 | 90 mm PVC Coupler Fabricated 4 KSC |
| 542 | 110 mm PVC Coupler Fabricated 4 KSC |
| 543 | 140 mm PVC Coupler Fabricated 4 KSC |
| 544 | 160 mm PVC Coupler Fabricated 4 KSC |
| 545 | 200 mm PVC Coupler Fabricated 4 KSC |
| 546 | Attending Leaks in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II - For DI Pipes |
| 547 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 548 | Dewatering using 7.5 HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 549 | 600 mm DI K7 Pipe |
| 550 | 400 mm DI K7 Pipe |
| 551 | 350 mm DI K7 Pipe |
| 552 | 300 mm DI K7 Pipe |
| 553 | 250 mm DI K7 Pipe |
| 554 | 200 mm DI K7 Pipe |
| 555 | Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 556 | 600 mm DI K7 Pipe |
| 557 | 400 mm DI K7 Pipe |
| 558 | 350 mm DI K7 Pipe |
| 559 | 300 mm DI K7 Pipe |
| 560 | 250 mm DI K7 Pipe |
| 561 | 200 mm DI K7 Pipe |
| 562 | Supply and delivery of Lead wool for Leak work DI pipeline including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers |
| 563 | 600 mm DI K7 Pipe |
| 564 | 400 mm DI K7 Pipe |
| 565 | 350 mm DI K7 Pipe |
| 566 | 300 mm DI K7 Pipe |
| 567 | 250 mm DI K7 Pipe |
| 568 | 200 mm DI K7 Pipe |
| 569 | Refilling with excavated soil (other than sand) complying with standard specification complete and as directed by the TWAD Board officers. |
| 570 | Rewinding of Motors in pumping stations iod in the Electrical, Mechanical and Elctro- mechanical items to bring back the scheme / components into normal running conditition as per specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 571 | 0.5 HP |
| 572 | 1.5 HP |
| 573 | 7.5 HP |
| 574 | 10 HP |
| 575 | 12.5 HP |
| 576 | 15 HP |
| 577 | 30 HP |
| 578 | 35 HP |
| 579 | Rewinding of motor and repair works to Centifugal HSC Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers. |
| 580 | 40 HP |
| 581 | 50 HP |
| 582 | 100 HP |
| 583 | 120 HP |
| 584 | Rewinding of motor and repair works to Vertical Turbine Motors including cost of all materials, conveyance charges, labour charges for removing and re-erection of Centifugal HSC Motots etc., complete and as directed by TWAD Board Officers -50 Hp |
| 585 | Repair and reconditioning works to HSC centrifugal Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers. |
| 586 | 30 HP |
| 587 | 40 HP |
| 588 | 50 HP |
| 589 | 100 HP |
| 590 | 120 HP |
| 591 | Repair and reconditioning works to Vertical Turbine Pumpset including cost of all material (exluding Bronze impeller ), conveyance ,labour charges for removing and re-erection of centrifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers- 50 HP |
| 592 | Attending Repair, Rectification and reconditioning of CI Sluice valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 593 | 300 mm CI Sluice valve |
| 594 | 250 mm CI Sluice valve |
| 595 | 150 mm CI Sluice valve |
| 596 | 100 mm CI Sluice valve |
| 597 | 65 mm CI Sluice valve |
| 598 | 50 mm CI Sluice valve |
| 599 | Attending Repair, Rectification and reconditioning of CI non return valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 600 | 300 mm CI NRV valve |
| 601 | 250 mm CI NRV valve |
| 602 | 150 mm CI NRV valve |
| 603 | 100 mm CI NRV valve |
| 604 | 65 mm CI NRV valve |
| 605 | 50 mm CI NRV valve |
| 606 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 607 | 40mm CI Double Air valve |
| 608 | 50mm CI Double Air valve |
| 609 | 80mm CI Double Air valve |
| 610 | 100mm DI Single Champer Air release valve |
| 611 | 150 mm DI Single Champer Air release valve Attending cable fault by replacing the cable |
| 612 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 613 | 3 core 10 Sq. mm aluminium cable |
| 614 | 3 core 16 Sq. mm aluminium cable |
| 615 | 3 core 25 Sq. mm aluminium cable |
| 616 | 3 core 35 Sq. mm aluminium cable |
| 617 | 3 core 50 Sq. mm aluminium cable |
| 618 | 3 core 70 Sq. mm aluminium cable |
| 619 | 3 core 120 Sq. mm aluminium cable |
| 620 | 3 core 185 Sq. mm aluminium cable |
| 621 | 3 core 400 Sq. mm aluminium cable |
| 622 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 623 | 3 core 10 Sq. mm aluminium cable |
| 624 | 3 core 16 Sq. mm aluminium cable |
| 625 | 3 core 25 Sq. mm aluminium cable |
| 626 | 3 core 35 Sq. mm aluminium cable |
| 627 | 3 core 50 Sq. mm aluminium cable |
| 628 | 3 core 70 Sq. mm aluminium cable |
| 629 | 3 core 120 Sq. mm aluminium cable |
| 630 | 3 core 185 Sq. mm aluminium cable |
| 631 | 3 core 400 Sq. mm aluminium cable |
| 632 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 633 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 634 | Supply and delivery of 12 Amps\440V Electro magnetic Contactors |
| 635 | Supply and delivery of 18 Amps\440V Electro magnetic Contactors |
| 636 | Supply and delivery of 22 Amps\440V Electro magnetic Contactors |
| 637 | Supply and delivery of 25 Amps\440V Electro magnetic Contactors |
| 638 | Supply and delivery of 32 Amps\440V Electro magnetic Contactors |
| 639 | Supply and delivery of 40 Amps\440V Electro magnetic Contactors |
| 640 | Supply and delivery of 70 Amps\440V Electro magnetic Contactors |
| 641 | Supply and delivery of 80 Amps\440V Electro magnetic Contactors |
| 642 | Supply and delivery of 120 Amps\440V Electro magnetic Contactors |
| 643 | Supply and delivery of 250 Amps\440V Electro magnetic Contactors |
| 644 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 645 | Upto 5A |
| 646 | Upto 5A - 10A |
| 647 | Upto 10A - 20A |
| 648 | Upto 30A - 50A |
| 649 | Upto 75A - 110A |
| 650 | Upto 110A - 150A |
| 651 | Upto 150A - 200A |
| 652 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 653 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 654 | Supply and delivery of Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Officers |
| 655 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately)etc., complete and as directed by TWAD Board Officers |
| 656 | 0.5 HPStarter |
| 657 | 1 HPStarter |
| 658 | 1.5 HP Starter |
| 659 | 2 HP Starter |
| 660 | 3 HP Starter |
| 661 | 5 HP Starter |
| 662 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches,wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 663 | 7.5 HP Starter |
| 664 | 10 HP Starter |
| 665 | 12.5 HP Starter |
| 666 | 15 HP Starter |
| 667 | FULLY AUTOMATIC AIR BREAK STAR DELTA STARTER WITH SINGLE PHASE PREVENTOR WITH AMMETER CONFIRMING TO IS 13947, IEC 60947-1 WITH AUTO RESTART FACILITY FOR PUMP HOUSES WHERE PANEL BOARDS ARE AVAILABLESupply and delivery of Star-Delta starter where panel boards are available confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter(65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector swicth, Minature Circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers |
| 668 | 30 HP Starter |
| 669 | Supply and delivery of following Range AMPS 3 pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 670 | 32-100 Amps 3 Pole MCCB Switch |
| 671 | Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) to control EB supply from E.B Pole to Main Panel Board etc., complete and as directed by TWAD Board Officers |
| 672 | 160 Amps MCCB Switch |
| 673 | 200 Amps MCCB Switch |
| 674 | 250 Amps MCCB Switch |
| 675 | 320 Amps MCCB Switch |
| 676 | 400 Amps MCCB Switch |
| 677 | Supply and delivery of the following gate valves etc., complete and as directed by TWAD Board Officers at the site of work to carryout the general maintenace works etc., complete and as directed by TWAD Board Officers |
| 678 | 50 mm Gate valve |
| 679 | 65 mm Gate valve |
| 680 | 80 mm Gate valve |
| 681 | Attending Major Repair works for following KVA/443V Transformer For 400 KVA |
| 682 | Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 683 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 684 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 685 | Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 686 | Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 687 | Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 688 | Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 689 | Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 690 | Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 691 | Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 692 | Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 693 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 694 | Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 695 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 696 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 697 | Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 698 | Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers For 315 KVA |
| 699 | Labour Charges for dismantling of 315 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 700 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 701 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 702 | Supply and delievery of 3 phase insulation material to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 703 | Supply and delievery of new transformer oil to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 704 | Supply and delievery of 11KV HV bushing with Metal parts to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 705 | Supply and delievery of 433V LV bushing copper rod to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 706 | Supply and delievery of silica gel breather to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 707 | Supply and delievery of capillary type thermometer including accessories to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 708 | Supply and delievery of gasket & oil seals to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 709 | Supply and delievery of paint to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 710 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 315 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 711 | Charges for Transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 712 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 713 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 714 | Charges for Re erection of 315 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 715 | Conveyance charges for transformers unit from Site to work shop site and work shop site to site completion of rectification works etc complete as directed by Twad Board officers For 250 KVA |
| 716 | Labour Charges for dismantling of 250 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers |
| 717 | Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 718 | Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 719 | Supply and delievery of 3 phase insulation material to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 720 | Supply and delievery of new transformer oil to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 721 | Supply and delievery of 11KV HV bushing with Metal parts to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 722 | Supply and delievery of 433V LV bushing copper rod to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 723 | Supply and delievery of silica gel breather to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 724 | Supply and delievery of capillary type thermometer including accessories to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 725 | Supply and delievery of gasket & oil seals to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 726 | Supply and delievery of paint to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 727 | Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 250 KVA Transformer etc.,complete as directed by TWAD board officers. |
| 728 | Charges for Transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specification as directed by TWAD Board Officers. |
| 729 | Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS specifications as directed by TWAD board officers.. |
| 730 | Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS specifications as directed by TWAD board officers. |
| 731 | Charges for Re erection of 250 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers. |
| 732 | Conveyance charges for transformers unit from site to work shop site and work shop to site completion of rectification works etc complete as directed by Twad Board officers |
| 733 | Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete. and as directed by TWAD Board Officers Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers |
| 734 | 0.15 capacity of sump |
| 735 | 0.20 capacity of sump |
| 736 | 0.25 capacity of sump |
| 737 | 0.30 capacity of sump |
| 738 | 0.35 capacity of sump |
| 739 | 0.40 capacity of sump |
| 740 | 0.45 capacity of sump |
| 741 | 0.50 capacity of sump |
| 742 | 0.55 capacity of sump |
| 743 | 0.60 capacity of sump |
| 744 | 0.65 capacity of sump |
| 745 | 0.70 capacity of sump |
| 746 | 0.75 capacity of sump |
| 747 | 0.80 capacity of sump |
| 748 | 0.85 capacity of sump |
| 749 | 0.90 capacity of sump |
| 750 | 0.95 capacity of sump |
| 751 | 1.00 capacity of sump |
| 752 | 1.05 capacity of sump |
| 753 | 1.15 capacity of sump |
| 754 | 1.20 capacity of sump |
| 755 | 1.30 capacity of sump |
| 756 | 1.55 capacity of sump |
| 757 | 1.65 capacity of sump |
| 758 | 1.75 capacity of sump |
| 759 | 1.85 capacity of sump |
| 760 | 1.95 capacity of sump |
| 761 | 2.05 capacity of sump |
| 762 | 2.35 capacity of sump |
| 763 | 2.45 capacity of sump |
| 764 | 2.50 capacity of sump |
| 765 | 2.55 capacity of sump |
| 766 | 2.85 capacity of sump |
| 767 | 3.10 capacity of sump |
| 768 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers |
| 769 | Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. |
| 770 | Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers. |
| 771 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total III -2028-2029 |
| 772 | 2.0 For the year 2026-2027 (From 01.01.2027 to 31.03.2027) |
| 773 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.13MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers.Totally 11.700 ML (0.13*90) |
| 774 | Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 775 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 776 | 75mm PVC 4KSC |
| 777 | 90mm PVC 4 KSC |
| 778 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 779 | 75mm PVC 4KSC |
| 780 | 90mm PVC 4 KSC |
| 781 | 75 mm PVC Coupler Fabricated 4 KSC |
| 782 | 90 mm PVC Coupler Fabricated 4 KSC |
| 783 | Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 784 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 785 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 786 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 787 | Upto 5A |
| 788 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 789 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers Attending cable fault by replacing the cable |
| 790 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 791 | 3 core 4 Sq. mm aluminium cable |
| 792 | Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work |
| 793 | 3 core 4 Sq. mm aluminium cable |
| 794 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 795 | 3 core 4 Sq. mm aluminium cable |
| 796 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 797 | 50mm CI Double Air valve |
| 798 | 50mm Gate valve |
| 799 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc. complete and as directed by TWAD Board Officers |
| 800 | Infiltration wells |
| 801 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers |
| 802 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total I - 2026-27 For the year 2027-2028 (From 01.04.2027 to 31.03.2028) |
| 803 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.13 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers. Totally 47.580 ML (0.13*366) |
| 804 | Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 805 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 806 | 75mm PVC 4KSC |
| 807 | 90mm PVC 4 KSC |
| 808 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 809 | 75mm PVC 4KSC |
| 810 | 90mm PVC 4 KSC |
| 811 | 75 mm PVC Coupler Fabricated 4 KSC |
| 812 | 90 mm PVC Coupler Fabricated 4 KSC |
| 813 | Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 814 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 815 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 816 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 817 | Upto 5A |
| 818 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 819 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers Attending cable fault by replacing the cable |
| 820 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 821 | 3 core 4 Sq. mm aluminium cable |
| 822 | Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work |
| 823 | 3 core 4 Sq. mm aluminium cable |
| 824 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 825 | 3 core 4 Sq. mm aluminium cable |
| 826 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 827 | 50mm CI Double Air valve |
| 828 | 50mm Gate valve |
| 829 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc. complete and as directed by TWAD Board Officers |
| 830 | Infiltration wells |
| 831 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers |
| 832 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total II -2027-2028 For the year 2028-2029 (From 01.04.2028 to 31.03.2029) |
| 833 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 0.12MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers. Totally 47.450 ML (0.13*365) |
| 834 | Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers |
| 835 | Removing the burst P.V.C. Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers |
| 836 | 75mm PVC 4KSC |
| 837 | 90mm PVC 4 KSC |
| 838 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 839 | 75mm PVC 4KSC |
| 840 | 90mm PVC 4 KSC |
| 841 | 75 mm PVC Coupler Fabricated 4 KSC |
| 842 | 90 mm PVC Coupler Fabricated 4 KSC |
| 843 | Rewinding of motor and reconditioning of pump and repair works to Open Well Submersible Pump Sets including cost of all materials, conveyance charges, labour charges for removing and re-erection of Submersible pumpsets etc., complete and as directed by TWAD Board Officers |
| 844 | Supply, delivery and fixing of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1 etc., complete and as directed by TWAD Board Officers |
| 845 | Supply and delivery of 9 Amps\440V Electro magnetic Contactors |
| 846 | Supply, delivery and fixing of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers. |
| 847 | Upto 5A |
| 848 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 849 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers Attending cable fault by replacing the cable |
| 850 | Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers. |
| 851 | 3 core 4 Sq. mm aluminium cable |
| 852 | Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying below GL including earth work |
| 853 | 3 core 4 Sq. mm aluminium cable |
| 854 | Jonting the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers |
| 855 | 3 core 4 Sq. mm aluminium cable |
| 856 | Attending Repair, Rectification and reconditioning of CI Double Air Valve and DI single chamber air release valve including cost of all materials, conveyance, labour charges for removeing and re-erection etc., complete and as directed by TWAD Board Officers |
| 857 | 50mm CI Double Air valve |
| 858 | 50mm Gate valve |
| 859 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc. complete and as directed by TWAD Board Officers |
| 860 | Infiltration wells |
| 861 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers |
| 862 | Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers. Total III 2028-2029 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 20 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender