Tender For Operation And Maintenance Of The 8 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12C)
Tender Overview
Project Description
Tender for Operation And Maintenance Of The 8 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12C)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Nov-2026 | Amendment to Bid document | Technical Bid | 07-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Operation and maintenance of the 8 Nos of CWSS in Tenkasi District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 12C) |
| 2 | CWSS TO Sencottai Municipality, 4 TPs and UTP and AND 47 Rural Habitations in Tenkasi District |
| 3 | CWSS TO Keelapavur UTP, Iyathankattalai and 31 Habitations in Kadayam & Keelapavoor Union in Tenkasi District |
| 4 | CWSS TO Ayikudi, Achampudur, Vadakarai, Kilpadugai, Panpozhi and 151 Rural habitations in Kadayam, Keelapavoor, Tenkasi and Schencottai Union in Tenkasi District |
| 5 | CWSS TO Tenkasi MPTY, Courtallam, Ilanji and Melagaram TP in Tenkasi District |
| 6 | CWSS TO Venkadampatti - Poolankulam in Tenkasi District |
| 7 | Augmentation of WSS to 147 rural habitations under Sankarankoil and Alangulam CWSS in Tirunelveli District |
| 8 | CWSS TO 31 Habitations in Alangulam Union in Tenkasi District |
| 9 | CWSS TO Keelapavoor Town Panchayat ( PART) and 163 Rural Habitations in Kadayam ( PART) Pappakudi ( PART ), Keelapavoor ( PART ) Unions in Tenkasi District |
| 10 | Total Basic Value |
| 11 | Add GST @18% on Basic Value |
| 12 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 13 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 748.80 ML (8.32*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 14 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 15 | PSC Pipes of various sizes |
| 16 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 17 | 400 mm dia PSC Pipe |
| 18 | 450 mm dia PSC Pipe |
| 19 | 500 mm dia PSC Pipe |
| 20 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 21 | 400 mm dia PSC Pipe |
| 22 | 450 mm dia PSC Pipe |
| 23 | 500 mm dia PSC Pipe |
| 24 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 25 | 400 mm PSC Pipe |
| 26 | 450 mm PSC Pipe |
| 27 | 500 mm PSC Pipe |
| 28 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 29 | 400 mm PSC Pipe |
| 30 | 450 mm PSC Pipe |
| 31 | 500 mm PSC Pipe |
| 32 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 33 | PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 34 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 35 | 400 mm MS Pipe |
| 36 | 450 mm MS Pipe |
| 37 | 500 mm MS Pipe |
| 38 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 39 | 400 mm MS Pipe |
| 40 | 450 mm MS Pipe |
| 41 | 500 mm MS Pipe |
| 42 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 43 | 400mm MS pipe |
| 44 | 450mm MS pipe |
| 45 | 500mm MS pipe |
| 46 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 47 | 400mm MS pipe |
| 48 | 450mm MS pipe |
| 49 | 500mm MS pipe |
| 50 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 51 | 400mm MS pipe |
| 52 | 400mm Machine end |
| 53 | 450mm MS pipe |
| 54 | 450mm Machine end |
| 55 | 500mm MS pipe |
| 56 | 500mm Machine end |
| 57 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 58 | 400mm MS pipe |
| 59 | 450mm MS pipe |
| 60 | 500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 61 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 62 | For PVC Pipes of various sizes |
| 63 | For AC Pipes of various sizes |
| 64 | For PSC Pipes of various sizes |
| 65 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 66 | 63mm PVC 4 KSC |
| 67 | 75mm PVC 4 KSC |
| 68 | 90mm PVC 4 KSC |
| 69 | 110mm PVC 4KSC |
| 70 | 140mm PVC 4KSC |
| 71 | 160mm PVC 4KSC |
| 72 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 73 | 150 mm AC Pipes Class 15 |
| 74 | 200 mm AC Pipes Class 15 |
| 75 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 76 | 406.4 mm x 4 mm thick MS PIPE |
| 77 | 457 mm x 4 mm thick MS PIPE |
| 78 | 508 mm x 5 mm thick MS PIPE |
| 79 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 80 | 63 mm PVC Coupler Fabricated 4 KSC |
| 81 | 75 mm PVC Coupler Fabricated 4 KSC |
| 82 | 90 mm PVC Coupler Fabricated 4 KSC |
| 83 | 110 mm PVC Coupler Fabricated 4 KSC |
| 84 | 140 mm PVC Coupler Fabricated 4 KSC |
| 85 | 160 mm PVC Coupler Fabricated 4 KSC |
| 86 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 87 | 150 mm AC Pipes Class 15 |
| 88 | 200 mm AC Pipes Class 15 |
| 89 | Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers |
| 90 | 400 mm dia PSC Pipe |
| 91 | 450 mm dia PSC Pipe |
| 92 | 500 mm dia PSC Pipe |
| 93 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 94 | 63mm PVC 4KSC |
| 95 | 75mm PVC 4KSC |
| 96 | 90mm PVC 4 KSC |
| 97 | 110mm PVC 4KSC |
| 98 | 140mm PVC 4KSC |
| 99 | 160mm PVC 4KSC |
| 100 | 150 mm dia AC Class 15 Pipe |
| 101 | 200 mm dia AC Class 15 Pipe |
| 102 | 400 mm PSC Pipes |
| 103 | 450 mm PSC Pipes |
| 104 | 500 mm PSC Pipes |
| 105 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 106 | 50 mm GI Pipe |
| 107 | 65 mm GI Pipe |
| 108 | 80 mm GI Pipe |
| 109 | 100 mm GI Pipe |
| 110 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 111 | 50 mm GI Pipe |
| 112 | 65 mm GI Pipe |
| 113 | 80 mm GI Pipe |
| 114 | 100 mm GI Pipe |
| 115 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 116 | 50 mm GI Pipe |
| 117 | 65 mm GI Pipe |
| 118 | 80 mm GI Pipe |
| 119 | 100 mm GI Pipe |
| 120 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 121 | 50 mm GI Pipe |
| 122 | 65 mm GI Pipe |
| 123 | 80 mm GI Pipe |
| 124 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 125 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 126 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well . |
| 127 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room |
| 128 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room |
| 129 | Pottalpudur sump |
| 130 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 131 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 132 | Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 133 | Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 134 | Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 135 | Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP |
| 136 | Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 137 | Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 138 | Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram |
| 139 | Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room |
| 140 | Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 141 | Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room |
| 142 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 143 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 144 | Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM |
| 145 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam |
| 146 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI |
| 147 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos |
| 148 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU |
| 149 | Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set |
| 150 | Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room |
| 151 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 152 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 153 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 154 | Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB |
| 155 | 400 Amps |
| 156 | 63 Amps |
| 157 | 250 Amps |
| 158 | 32 Amps |
| 159 | 160 Amps |
| 160 | 3 Pole MCCB |
| 161 | 32 Amps |
| 162 | 63 Amps |
| 163 | 100 Amps |
| 164 | 200 Amps |
| 165 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 166 | 9 Amps\440V |
| 167 | 12 Amps\440V |
| 168 | 18 Amps\440V |
| 169 | 25 Amps\440V |
| 170 | 32 Amps\440V |
| 171 | 40 Amps\440V |
| 172 | 45 Amps\440V |
| 173 | 70 Amps\440V |
| 174 | 95 Amps\440V |
| 175 | 140 Amps\440V |
| 176 | 550 Amps\440V |
| 177 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 178 | Upto 5A |
| 179 | Upto 5A-10A |
| 180 | Upto 10A-20A |
| 181 | Upto 20A-30A |
| 182 | Upto 30A-50A |
| 183 | Upto 50A-75A |
| 184 | Upto 75A-110A |
| 185 | Upto 200A-300A |
| 186 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 187 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers. |
| 188 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 189 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 190 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 191 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 192 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 193 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 194 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 195 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 196 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 197 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 198 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 199 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 200 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 201 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 202 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 203 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 204 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 205 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 206 | Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 207 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 208 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 209 | Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 210 | Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 211 | Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 212 | Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 213 | Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 214 | Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 215 | Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 216 | Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 217 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 218 | Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 219 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 220 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 221 | Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 222 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 223 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 224 | For 2 HP Starter - 1No |
| 225 | For 3 HP Starter - 1 No |
| 226 | For 5 HP Starter - 1 No |
| 227 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers. |
| 228 | For 7.5 HP Starter - 1No |
| 229 | For 10 HP Starter - 1No |
| 230 | For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 231 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 232 | 500 mm CI Sluice valve |
| 233 | 400 mm CI Sluice valve |
| 234 | 250 mm CI Scour valve |
| 235 | 300 mm CI Sluice valve |
| 236 | 300 mm CI NRV valve |
| 237 | 200 mm CI Sluice valve |
| 238 | 200 mm CI NRV valve |
| 239 | 150 mm CI Sluice valve |
| 240 | 150 mm CI NRV valve |
| 241 | 100 mm CI Sluice valve |
| 242 | 100 mm CI NRV valve |
| 243 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 244 | 50 mm Gate valve |
| 245 | 65 mm Gate valve |
| 246 | 80 mm Gate valve |
| 247 | 100 mm Gate valve |
| 248 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 249 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 250 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 251 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 252 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 253 | 5.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram |
| 254 | 3.5 LL capacity of sump @ shencottai |
| 255 | 1.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu |
| 256 | 0.15 LL capacity of sump @ Schenkottai |
| 257 | 0.15 LL capacity of sump @ Shencottai For the year 2026-27 (From 01.04.2027 to 31.03.2028) For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 258 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3036.80 ML (8.32*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 259 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 260 | PSC Pipes of various sizes |
| 261 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 262 | 400 mm dia PSC Pipe |
| 263 | 450 mm dia PSC Pipe |
| 264 | 500 mm dia PSC Pipe |
| 265 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 266 | 400 mm dia PSC Pipe |
| 267 | 450 mm dia PSC Pipe |
| 268 | 500 mm dia PSC Pipe |
| 269 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 270 | 400 mm PSC Pipe |
| 271 | 450 mm PSC Pipe |
| 272 | 500 mm PSC Pipe |
| 273 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 274 | 400 mm PSC Pipe |
| 275 | 450 mm PSC Pipe |
| 276 | 500 mm PSC Pipe |
| 277 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 278 | PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 279 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 280 | 400 mm MS Pipe |
| 281 | 450 mm MS Pipe |
| 282 | 500 mm MS Pipe |
| 283 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 284 | 400 mm MS Pipe |
| 285 | 450 mm MS Pipe |
| 286 | 500 mm MS Pipe |
| 287 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 288 | 400mm MS pipe |
| 289 | 450mm MS pipe |
| 290 | 500mm MS pipe |
| 291 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 292 | 400mm MS pipe |
| 293 | 450mm MS pipe |
| 294 | 500mm MS pipe |
| 295 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 296 | 400mm MS pipe |
| 297 | 400mm Machine end |
| 298 | 450mm MS pipe |
| 299 | 450mm Machine end |
| 300 | 500mm MS pipe |
| 301 | 500mm Machine end |
| 302 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 303 | 400mm MS pipe |
| 304 | 450mm MS pipe |
| 305 | 500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 306 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 307 | For PVC Pipes of various sizes |
| 308 | For AC Pipes of various sizes |
| 309 | For PSC Pipes of various sizes |
| 310 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 311 | 63mm PVC 4 KSC |
| 312 | 75mm PVC 4 KSC |
| 313 | 90mm PVC 4 KSC |
| 314 | 110mm PVC 4KSC |
| 315 | 140mm PVC 4KSC |
| 316 | 160mm PVC 4KSC |
| 317 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 318 | 150 mm AC Pipes Class 15 |
| 319 | 200 mm AC Pipes Class 15 |
| 320 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 321 | 406.4 mm x 4 mm thick MS PIPE |
| 322 | 457 mm x 4 mm thick MS PIPE |
| 323 | 508 mm x 5 mm thick MS PIPE |
| 324 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 325 | 63 mm PVC Coupler Fabricated 4 KSC |
| 326 | 75 mm PVC Coupler Fabricated 4 KSC |
| 327 | 90 mm PVC Coupler Fabricated 4 KSC |
| 328 | 110 mm PVC Coupler Fabricated 4 KSC |
| 329 | 140 mm PVC Coupler Fabricated 4 KSC |
| 330 | 160 mm PVC Coupler Fabricated 4 KSC |
| 331 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 332 | 150 mm AC Pipes Class 15 |
| 333 | 200 mm AC Pipes Class 15 |
| 334 | Supply and delivery of Burst Arresting Flexible SS Clamps of wrap around Single section type upto 500mm diameter and maxi range double section type beyond 500mm OD of all rigid pipe sections. The clamp made of stainless steel SS304 metallic body of 0.8 to 1.0mm maximum thickness pasted with waffle gaskets of Natural / Nitrile / EPDM grade ( BS EN681-1) and fitted with self stabilizing finger type clamps of 200mm length SG grade malleable cast iron duly powder coated (BS2789 grade 400/12 ) and connected through fasteners of EN8 material with Zinc Coating ( BS 970 ) . Suitable width of the clamps to be decided by the Engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by TWAD Board officers. |
| 335 | 400 mm dia PSC Pipe |
| 336 | 450 mm dia PSC Pipe |
| 337 | 500 mm dia PSC Pipe |
| 338 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 339 | 63mm PVC 4KSC |
| 340 | 75mm PVC 4KSC |
| 341 | 90mm PVC 4 KSC |
| 342 | 110mm PVC 4KSC |
| 343 | 140mm PVC 4KSC |
| 344 | 160mm PVC 4KSC |
| 345 | 150 mm dia AC Class 15 Pipe |
| 346 | 200 mm dia AC Class 15 Pipe |
| 347 | 400 mm PSC Pipes |
| 348 | 450 mm PSC Pipes |
| 349 | 500 mm PSC Pipes |
| 350 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 351 | 50 mm GI Pipe |
| 352 | 65 mm GI Pipe |
| 353 | 80 mm GI Pipe |
| 354 | 100 mm GI Pipe |
| 355 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 356 | 50 mm GI Pipe |
| 357 | 65 mm GI Pipe |
| 358 | 80 mm GI Pipe |
| 359 | 100 mm GI Pipe |
| 360 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 361 | 50 mm GI Pipe |
| 362 | 65 mm GI Pipe |
| 363 | 80 mm GI Pipe |
| 364 | 100 mm GI Pipe |
| 365 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 366 | 50 mm GI Pipe |
| 367 | 65 mm GI Pipe |
| 368 | 80 mm GI Pipe |
| 369 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 370 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 371 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well . |
| 372 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room |
| 373 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room |
| 374 | Pottalpudur sump |
| 375 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 376 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 377 | Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 378 | Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 379 | Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 380 | Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP |
| 381 | Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 382 | Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 383 | Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram |
| 384 | Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room |
| 385 | Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 386 | Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room |
| 387 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 388 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 389 | Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM |
| 390 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam |
| 391 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI |
| 392 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos |
| 393 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU |
| 394 | Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set |
| 395 | Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room |
| 396 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 397 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 398 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 399 | Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB |
| 400 | 400 Amps |
| 401 | 63 Amps |
| 402 | 250 Amps |
| 403 | 32 Amps |
| 404 | 160 Amps |
| 405 | 3 Pole MCCB |
| 406 | 32 Amps |
| 407 | 63 Amps |
| 408 | 100 Amps |
| 409 | 200 Amps |
| 410 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 411 | 9 Amps\440V |
| 412 | 12 Amps\440V |
| 413 | 18 Amps\440V |
| 414 | 25 Amps\440V |
| 415 | 32 Amps\440V |
| 416 | 40 Amps\440V |
| 417 | 45 Amps\440V |
| 418 | 70 Amps\440V |
| 419 | 95 Amps\440V |
| 420 | 140 Amps\440V |
| 421 | 550 Amps\440V |
| 422 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 423 | Upto 5A |
| 424 | Upto 5A-10A |
| 425 | Upto 10A-20A |
| 426 | Upto 20A-30A |
| 427 | Upto 30A-50A |
| 428 | Upto 50A-75A |
| 429 | Upto 75A-110A |
| 430 | Upto 200A-300A |
| 431 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 432 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers. |
| 433 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 434 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 435 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 436 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 437 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 438 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 439 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 440 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 441 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 442 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 443 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 444 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 445 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 446 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 447 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 448 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 449 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 450 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 451 | Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 452 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 453 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 454 | Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 455 | Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 456 | Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 457 | Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 458 | Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 459 | Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 460 | Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 461 | Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 462 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 463 | Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 464 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 465 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 466 | Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 467 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 468 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 469 | For 2 HP Starter - 1No |
| 470 | For 3 HP Starter - 1 No |
| 471 | For 5 HP Starter - 1 No |
| 472 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers. |
| 473 | For 7.5 HP Starter - 1No |
| 474 | For 10 HP Starter - 1No |
| 475 | For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 476 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 477 | 500 mm CI Sluice valve |
| 478 | 400 mm CI Sluice valve |
| 479 | 250 mm CI Scour valve |
| 480 | 300 mm CI Sluice valve |
| 481 | 300 mm CI NRV valve |
| 482 | 200 mm CI Sluice valve |
| 483 | 200 mm CI NRV valve |
| 484 | 150 mm CI Sluice valve |
| 485 | 150 mm CI NRV valve |
| 486 | 100 mm CI Sluice valve |
| 487 | 100 mm CI NRV valve |
| 488 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 489 | 50 mm Gate valve |
| 490 | 65 mm Gate valve |
| 491 | 80 mm Gate valve |
| 492 | 100 mm Gate valve |
| 493 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 494 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 495 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 496 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 497 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 498 | 5.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram |
| 499 | 3.5 LL capacity of sump @ shencottai |
| 500 | 1.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu |
| 501 | 0.15 LL capacity of sump @ Schenkottai |
| 502 | 0.15 LL capacity of sump @ Shencottai For the year 2028-29 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 503 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3036.80 ML (8.32*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 504 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 505 | PSC Pipes of various sizes |
| 506 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 507 | 400 mm dia PSC Pipe |
| 508 | 450 mm dia PSC Pipe |
| 509 | 500 mm dia PSC Pipe |
| 510 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 511 | 400 mm dia PSC Pipe |
| 512 | 450 mm dia PSC Pipe |
| 513 | 500 mm dia PSC Pipe |
| 514 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 515 | 400 mm PSC Pipe |
| 516 | 450 mm PSC Pipe |
| 517 | 500 mm PSC Pipe |
| 518 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 519 | 400 mm PSC Pipe |
| 520 | 450 mm PSC Pipe |
| 521 | 500 mm PSC Pipe |
| 522 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 523 | PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 524 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 525 | 400 mm MS Pipe |
| 526 | 450 mm MS Pipe |
| 527 | 500 mm MS Pipe |
| 528 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 529 | 400 mm MS Pipe |
| 530 | 450 mm MS Pipe |
| 531 | 500 mm MS Pipe |
| 532 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 533 | 400mm MS pipe |
| 534 | 450mm MS pipe |
| 535 | 500mm MS pipe |
| 536 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 537 | 400mm MS pipe |
| 538 | 450mm MS pipe |
| 539 | 500mm MS pipe |
| 540 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 541 | 400mm MS pipe |
| 542 | 400mm Machine end |
| 543 | 450mm MS pipe |
| 544 | 450mm Machine end |
| 545 | 500mm MS pipe |
| 546 | 500mm Machine end |
| 547 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 548 | 400mm MS pipe |
| 549 | 450mm MS pipe |
| 550 | 500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 551 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 552 | For PVC Pipes of various sizes |
| 553 | For AC Pipes of various sizes |
| 554 | For PSC Pipes of various sizes |
| 555 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 556 | 63mm PVC 4 KSC |
| 557 | 75mm PVC 4 KSC |
| 558 | 90mm PVC 4 KSC |
| 559 | 110mm PVC 4KSC |
| 560 | 140mm PVC 4KSC |
| 561 | 160mm PVC 4KSC |
| 562 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 563 | 150 mm AC Pipes Class 15 |
| 564 | 200 mm AC Pipes Class 15 |
| 565 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 566 | 406.4 mm x 4 mm thick MS PIPE |
| 567 | 457 mm x 4 mm thick MS PIPE |
| 568 | 508 mm x 5 mm thick MS PIPE |
| 569 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 570 | 63 mm PVC Coupler Fabricated 4 KSC |
| 571 | 75 mm PVC Coupler Fabricated 4 KSC |
| 572 | 90 mm PVC Coupler Fabricated 4 KSC |
| 573 | 110 mm PVC Coupler Fabricated 4 KSC |
| 574 | 140 mm PVC Coupler Fabricated 4 KSC |
| 575 | 160 mm PVC Coupler Fabricated 4 KSC |
| 576 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 577 | 150 mm AC Pipes Class 15 |
| 578 | 200 mm AC Pipes Class 15 |
| 579 | Supply and delivery of Burst Arresting Flexible SS Clamps of wrap around Single section type upto 500mm diameter and maxi range double section type beyond 500mm OD of all rigid pipe sections. The clamp made of stainless steel SS304 metallic body of 0.8 to 1.0mm maximum thickness pasted with waffle gaskets of Natural / Nitrile / EPDM grade ( BS EN681-1) and fitted with self stabilizing finger type clamps of 200mm length SG grade malleable cast iron duly powder coated (BS2789 grade 400/12 ) and connected through fasteners of EN8 material with Zinc Coating ( BS 970 ) . Suitable width of the clamps to be decided by the Engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by TWAD Board officers. |
| 580 | 400 mm dia PSC Pipe |
| 581 | 450 mm dia PSC Pipe |
| 582 | 500 mm dia PSC Pipe |
| 583 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 584 | 63mm PVC 4KSC |
| 585 | 75mm PVC 4KSC |
| 586 | 90mm PVC 4 KSC |
| 587 | 110mm PVC 4KSC |
| 588 | 140mm PVC 4KSC |
| 589 | 160mm PVC 4KSC |
| 590 | 150 mm dia AC Class 15 Pipe |
| 591 | 200 mm dia AC Class 15 Pipe |
| 592 | 400 mm PSC Pipes |
| 593 | 450 mm PSC Pipes |
| 594 | 500 mm PSC Pipes |
| 595 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 596 | 50 mm GI Pipe |
| 597 | 65 mm GI Pipe |
| 598 | 80 mm GI Pipe |
| 599 | 100 mm GI Pipe |
| 600 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 601 | 50 mm GI Pipe |
| 602 | 65 mm GI Pipe |
| 603 | 80 mm GI Pipe |
| 604 | 100 mm GI Pipe |
| 605 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 606 | 50 mm GI Pipe |
| 607 | 65 mm GI Pipe |
| 608 | 80 mm GI Pipe |
| 609 | 100 mm GI Pipe |
| 610 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 611 | 50 mm GI Pipe |
| 612 | 65 mm GI Pipe |
| 613 | 80 mm GI Pipe |
| 614 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 615 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 616 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well . |
| 617 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room |
| 618 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room |
| 619 | Pottalpudur sump |
| 620 | Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 621 | Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 622 | Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 623 | Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 624 | Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room |
| 625 | Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP |
| 626 | Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 627 | Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room |
| 628 | Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram |
| 629 | Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room |
| 630 | Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room |
| 631 | Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room |
| 632 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 633 | Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam |
| 634 | Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM |
| 635 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam |
| 636 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI |
| 637 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos |
| 638 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU |
| 639 | Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set |
| 640 | Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room |
| 641 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 642 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 643 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 644 | Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB |
| 645 | 400 Amps |
| 646 | 63 Amps |
| 647 | 250 Amps |
| 648 | 32 Amps |
| 649 | 160 Amps |
| 650 | 3 Pole MCCB |
| 651 | 32 Amps |
| 652 | 63 Amps |
| 653 | 100 Amps |
| 654 | 200 Amps |
| 655 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 656 | 9 Amps\440V |
| 657 | 18 Amps\440V |
| 658 | 25 Amps\440V |
| 659 | 32 Amps\440V |
| 660 | 40 Amps\440V |
| 661 | 45 Amps\440V |
| 662 | 70 Amps\440V |
| 663 | 95 Amps\440V |
| 664 | 140 Amps\440V |
| 665 | 550 Amps\440V |
| 666 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 667 | Upto 5A |
| 668 | Upto 5A-10A |
| 669 | Upto 10A-20A |
| 670 | Upto 20A-30A |
| 671 | Upto 30A-50A |
| 672 | Upto 50A-75A |
| 673 | Upto 75A-110A |
| 674 | Upto 200A-300A |
| 675 | Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers |
| 676 | Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers. |
| 677 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 678 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 679 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 680 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 681 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 682 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 683 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 684 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 685 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 686 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 687 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 688 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 689 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 690 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 691 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 692 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 693 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 694 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 695 | Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 696 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 697 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 698 | Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 699 | Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 700 | Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 701 | Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 702 | Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 703 | Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 704 | Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 705 | Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 706 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 707 | Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 708 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 709 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 710 | Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 711 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 712 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 713 | For 2 HP Starter - 1No |
| 714 | For 3 HP Starter - 1 No |
| 715 | For 5 HP Starter - 1 No |
| 716 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers. |
| 717 | For 7.5 HP Starter - 1No |
| 718 | For 10 HP Starter - 1No |
| 719 | For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 720 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 721 | 500 mm CI Sluice valve |
| 722 | 400 mm CI Sluice valve |
| 723 | 250 mm CI Scour valve |
| 724 | 300 mm CI Sluice valve |
| 725 | 300 mm CI NRV valve |
| 726 | 200 mm CI Sluice valve |
| 727 | 200 mm CI NRV valve |
| 728 | 150 mm CI Sluice valve |
| 729 | 150 mm CI NRV valve |
| 730 | 100 mm CI Sluice valve |
| 731 | 100 mm CI NRV valve |
| 732 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 733 | 50 mm Gate valve |
| 734 | 65 mm Gate valve |
| 735 | 80 mm Gate valve |
| 736 | 100 mm Gate valve |
| 737 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 738 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 739 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 740 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 741 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 742 | 5.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram |
| 743 | 3.5 LL capacity of sump @ shencottai |
| 744 | 1.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu |
| 745 | 0.15 LL capacity of sump @ Schenkottai |
| 746 | 0.15 LL capacity of sump @ Shencottai |
| 747 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 748 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 166.5 ML (1.85*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 749 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 750 | AC Pipes of various sizes |
| 751 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 752 | 200 mm dia AC Pipe |
| 753 | 250 mm dia AC Pipe |
| 754 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 755 | 200 mm dia AC Pipe |
| 756 | 250 mm dia AC Pipe |
| 757 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 758 | 200 mm dia AC Pipe |
| 759 | 250 mm dia AC Pipe |
| 760 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 761 | 200 mm dia AC Pipe |
| 762 | 250 mm dia AC Pipe |
| 763 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 764 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 765 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 766 | For PVC Pipes of various sizes |
| 767 | For AC Pipes of various sizes |
| 768 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 769 | 63mm PVC 4 KSC |
| 770 | 75mm PVC 4 KSC |
| 771 | 90mm PVC 4 KSC |
| 772 | 110mm PVC 4KSC |
| 773 | 140mm PVC 4KSC |
| 774 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 775 | 200 mm AC Pipes Class 15 |
| 776 | 250 mm AC Pipes Class 15 |
| 777 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 778 | 63 mm PVC Coupler Fabricated 4 KSC |
| 779 | 75 mm PVC Coupler Fabricated 4 KSC |
| 780 | 90 mm PVC Coupler Fabricated 4 KSC |
| 781 | 110 mm PVC Coupler Fabricated 4 KSC |
| 782 | 140 mm PVC Coupler Fabricated 4 KSC |
| 783 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 784 | 200 mm AC Pipes Class 15 |
| 785 | 250 mm AC Pipes Class 15 |
| 786 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 787 | 63mm PVC 4KSC |
| 788 | 75mm PVC 4KSC |
| 789 | 90mm PVC 4 KSC |
| 790 | 110mm PVC 4KSC |
| 791 | 140mm PVC 4KSC |
| 792 | 200 mm dia AC Class 15 Pipe |
| 793 | 250 mm dia AC Class 15 Pipe |
| 794 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 795 | 50 mm GI Pipe |
| 796 | 65 mm GI Pipe |
| 797 | 80 mm GI Pipe |
| 798 | 100 mm GI Pipe |
| 799 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 800 | 50 mm GI Pipe |
| 801 | 65 mm GI Pipe |
| 802 | 80 mm GI Pipe |
| 803 | 100 mm GI Pipe |
| 804 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 805 | 50 mm GI Pipe |
| 806 | 65 mm GI Pipe |
| 807 | 80 mm GI Pipe |
| 808 | 100 mm GI Pipe |
| 809 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 810 | 50 mm GI Pipe |
| 811 | 65 mm GI Pipe |
| 812 | 80 mm GI Pipe |
| 813 | 100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS |
| 814 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW |
| 815 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 816 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 817 | Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works |
| 818 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump |
| 819 | Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur - |
| 820 | Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur |
| 821 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai |
| 822 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur |
| 823 | Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump |
| 824 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT |
| 825 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP |
| 826 | Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP |
| 827 | Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room |
| 828 | Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 829 | Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 830 | Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 831 | Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 832 | 32 Amps 3 Pole MCCB |
| 833 | 63 Amps 3 Pole MCCB |
| 834 | 100 Amps 3 Pole MCCB |
| 835 | 200 Amps 3 Pole MCCB |
| 836 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 837 | 9 Amps\440V |
| 838 | 12 Amps\440V |
| 839 | 25 Amps\440V |
| 840 | 45 Amps\440V |
| 841 | 70 Amps\440V |
| 842 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 843 | Upto 5A |
| 844 | Upto 5A-10A |
| 845 | Upto 20A-30A |
| 846 | Upto 30A-50A |
| 847 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 848 | For 2 HP Starter -1 No |
| 849 | For 3 HP Starter - -1 No |
| 850 | For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 851 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 852 | 250 mm CI Sluice valve |
| 853 | 150 mm CI Sluice valve |
| 854 | 250 mm CI NRV valve |
| 855 | 150 mm CI NRV valve |
| 856 | 100 mm Air valve |
| 857 | 80 mm Air valve |
| 858 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 859 | 50 mm Gate valve |
| 860 | 80 mm Gate valve |
| 861 | 100 mm Gate valve |
| 862 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS |
| 863 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 864 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 865 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 866 | 1.50 LL capacity of sump @Pappankulam, Thekumadathur |
| 867 | 1.00 LL capacity of sump @ Keelapavoor For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 868 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 675.25 ML (1.85*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 869 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 870 | AC Pipes of various sizes |
| 871 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 872 | 200 mm dia AC Pipe |
| 873 | 250 mm dia AC Pipe |
| 874 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 875 | 200 mm dia AC Pipe |
| 876 | 250 mm dia AC Pipe |
| 877 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 878 | 200 mm dia AC Pipe |
| 879 | 250 mm dia AC Pipe |
| 880 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 881 | 200 mm dia AC Pipe |
| 882 | 250 mm dia AC Pipe |
| 883 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 884 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 885 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 886 | For PVC Pipes of various sizes |
| 887 | For AC Pipes of various sizes |
| 888 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 889 | 63mm PVC 4 KSC |
| 890 | 75mm PVC 4 KSC |
| 891 | 90mm PVC 4 KSC |
| 892 | 110mm PVC 4KSC |
| 893 | 140mm PVC 4KSC |
| 894 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 895 | 200 mm AC Pipes Class 15 |
| 896 | 250 mm AC Pipes Class 15 |
| 897 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 898 | 63 mm PVC Coupler Fabricated 4 KSC |
| 899 | 75 mm PVC Coupler Fabricated 4 KSC |
| 900 | 90 mm PVC Coupler Fabricated 4 KSC |
| 901 | 110 mm PVC Coupler Fabricated 4 KSC |
| 902 | 140 mm PVC Coupler Fabricated 4 KSC |
| 903 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 904 | 200 mm AC Pipes Class 15 |
| 905 | 250 mm AC Pipes Class 15 |
| 906 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 907 | 63mm PVC 4KSC |
| 908 | 75mm PVC 4KSC |
| 909 | 90mm PVC 4 KSC |
| 910 | 110mm PVC 4KSC |
| 911 | 140mm PVC 4KSC |
| 912 | 200 mm dia AC Class 15 Pipe |
| 913 | 250 mm dia AC Class 15 Pipe |
| 914 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 915 | 50 mm GI Pipe |
| 916 | 65 mm GI Pipe |
| 917 | 80 mm GI Pipe |
| 918 | 100 mm GI Pipe |
| 919 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 920 | 50 mm GI Pipe |
| 921 | 65 mm GI Pipe |
| 922 | 80 mm GI Pipe |
| 923 | 100 mm GI Pipe |
| 924 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 925 | 50 mm GI Pipe |
| 926 | 65 mm GI Pipe |
| 927 | 80 mm GI Pipe |
| 928 | 100 mm GI Pipe |
| 929 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 930 | 50 mm GI Pipe |
| 931 | 65 mm GI Pipe |
| 932 | 80 mm GI Pipe |
| 933 | 100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS |
| 934 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW |
| 935 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 936 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 937 | Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works |
| 938 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump |
| 939 | Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur - |
| 940 | Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur |
| 941 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai |
| 942 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur |
| 943 | Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump |
| 944 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT |
| 945 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP |
| 946 | Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP |
| 947 | Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room |
| 948 | Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 949 | Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 950 | Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 951 | Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 952 | 32 Amps 3 Pole MCCB |
| 953 | 63 Amps 3 Pole MCCB |
| 954 | 100 Amps 3 Pole MCCB |
| 955 | 200 Amps 3 Pole MCCB |
| 956 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 957 | 9 Amps\440V |
| 958 | 12 Amps\440V |
| 959 | 25 Amps\440V |
| 960 | 45 Amps\440V |
| 961 | 70 Amps\440V |
| 962 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 963 | Upto 5A |
| 964 | Upto 5A-10A |
| 965 | Upto 20A-30A |
| 966 | Upto 30A-50A |
| 967 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 968 | For 2 HP Starter -1 No |
| 969 | For 3 HP Starter - -1 No |
| 970 | For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 971 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 972 | 250 mm CI Sluice valve |
| 973 | 150 mm CI Sluice valve |
| 974 | 250 mm CI NRV valve |
| 975 | 150 mm CI NRV valve |
| 976 | 100 mm Jet Air valve |
| 977 | 80 mm Jet Air valve |
| 978 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 979 | 50 mm Gate valve |
| 980 | 80 mm Gate valve |
| 981 | 100 mm Gate valve |
| 982 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS |
| 983 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 984 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 985 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 986 | 1.50 LL capacity of sump @Pappankulam, Thekumadathur |
| 987 | 1.00 LL capacity of sump @ Keelapavoor For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 988 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 675.25 ML (1.85*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 989 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 990 | AC Pipes of various sizes |
| 991 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 992 | 200 mm dia AC Pipe |
| 993 | 250 mm dia AC Pipe |
| 994 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 995 | 200 mm dia AC Pipe |
| 996 | 250 mm dia AC Pipe |
| 997 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 998 | 200 mm dia AC Pipe |
| 999 | 250 mm dia AC Pipe |
| 1000 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 1001 | 200 mm dia AC Pipe |
| 1002 | 250 mm dia AC Pipe |
| 1003 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1004 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 1005 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1006 | For PVC Pipes of various sizes |
| 1007 | For AC Pipes of various sizes |
| 1008 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 1009 | 63mm PVC 4 KSC |
| 1010 | 75mm PVC 4 KSC |
| 1011 | 90mm PVC 4 KSC |
| 1012 | 110mm PVC 4KSC |
| 1013 | 140mm PVC 4KSC |
| 1014 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 1015 | 200 mm AC Pipes Class 15 |
| 1016 | 250 mm AC Pipes Class 15 |
| 1017 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 1018 | 63 mm PVC Coupler Fabricated 4 KSC |
| 1019 | 75 mm PVC Coupler Fabricated 4 KSC |
| 1020 | 90 mm PVC Coupler Fabricated 4 KSC |
| 1021 | 110 mm PVC Coupler Fabricated 4 KSC |
| 1022 | 140 mm PVC Coupler Fabricated 4 KSC |
| 1023 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 1024 | 200 mm AC Pipes Class 15 |
| 1025 | 250 mm AC Pipes Class 15 |
| 1026 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 1027 | 63mm PVC 4KSC |
| 1028 | 75mm PVC 4KSC |
| 1029 | 90mm PVC 4 KSC |
| 1030 | 110mm PVC 4KSC |
| 1031 | 140mm PVC 4KSC |
| 1032 | 200 mm dia AC Class 15 Pipe |
| 1033 | 250 mm dia AC Class 15 Pipe |
| 1034 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 1035 | 50 mm GI Pipe |
| 1036 | 65 mm GI Pipe |
| 1037 | 80 mm GI Pipe |
| 1038 | 100 mm GI Pipe |
| 1039 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 1040 | 50 mm GI Pipe |
| 1041 | 65 mm GI Pipe |
| 1042 | 80 mm GI Pipe |
| 1043 | 100 mm GI Pipe |
| 1044 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 1045 | 50 mm GI Pipe |
| 1046 | 65 mm GI Pipe |
| 1047 | 80 mm GI Pipe |
| 1048 | 100 mm GI Pipe |
| 1049 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 1050 | 50 mm GI Pipe |
| 1051 | 65 mm GI Pipe |
| 1052 | 80 mm GI Pipe |
| 1053 | 100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS |
| 1054 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW |
| 1055 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 1056 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 1057 | Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works |
| 1058 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump |
| 1059 | Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur - |
| 1060 | Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur |
| 1061 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai |
| 1062 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur |
| 1063 | Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump |
| 1064 | Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT |
| 1065 | Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP |
| 1066 | Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP |
| 1067 | Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room |
| 1068 | Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 1069 | Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 1070 | Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 1071 | Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 1072 | 32 Amps 3 Pole MCCB |
| 1073 | 63 Amps 3 Pole MCCB |
| 1074 | 100 Amps 3 Pole MCCB |
| 1075 | 200 Amps 3 Pole MCCB |
| 1076 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 1077 | 9 Amps\440V |
| 1078 | 25 Amps\440V |
| 1079 | 45 Amps\440V |
| 1080 | 70 Amps\440V |
| 1081 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 1082 | Upto 5A |
| 1083 | Upto 5A-10A |
| 1084 | Upto 20A-30A |
| 1085 | Upto 30A-50A |
| 1086 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 1087 | For 2 HP Starter -1 No |
| 1088 | For 3 HP Starter - -1 No |
| 1089 | For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 1090 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 1091 | 250 mm CI Sluice valve |
| 1092 | 150 mm CI Sluice valve |
| 1093 | 250 mm CI NRV valve |
| 1094 | 150 mm CI NRV valve |
| 1095 | 100 mm Jet Air valve |
| 1096 | 80 mm Jet Air valve |
| 1097 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 1098 | 50 mm Gate valve |
| 1099 | 80 mm Gate valve |
| 1100 | 100 mm Gate valve |
| 1101 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS |
| 1102 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 1103 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 1104 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 1105 | 1.50 LL capacity of sump @Pappankulam, Thekumadathur |
| 1106 | 1.00 LL capacity of sump @ Keelapavoor |
| 1107 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 1108 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 750.60 ML (8.34*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 1109 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1110 | PSC Pipes of various sizes |
| 1111 | AC Pipes of various sizes |
| 1112 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1113 | 350 mm dia PSC Pipe |
| 1114 | 400 mm dia PSC Pipe |
| 1115 | 450 mm dia PSC Pipe |
| 1116 | 500 mm dia PSC Pipe |
| 1117 | 600 mm dia PSC Pipe |
| 1118 | 200 mm dia AC Pipe |
| 1119 | 250 mm dia AC Pipe |
| 1120 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1121 | 350 mm dia PSC Pipe |
| 1122 | 400 mm dia PSC Pipe |
| 1123 | 450 mm dia PSC Pipe |
| 1124 | 500 mm dia PSC Pipe |
| 1125 | 600 mm dia PSC Pipe |
| 1126 | 200 mm dia AC Pipe |
| 1127 | 250 mm dia AC Pipe |
| 1128 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 1129 | 350 mm dia PSC Pipe |
| 1130 | 400 mm dia PSC Pipe |
| 1131 | 450 mm dia PSC Pipe |
| 1132 | 500 mm dia PSC Pipe |
| 1133 | 600 mm dia PSC Pipe |
| 1134 | 200 mm dia AC Pipe |
| 1135 | 250 mm dia AC Pipe |
| 1136 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 1137 | 350 mm dia PSC Pipe |
| 1138 | 400 mm dia PSC Pipe |
| 1139 | 450 mm dia PSC Pipe |
| 1140 | 500 mm dia PSC Pipe |
| 1141 | 600 mm dia PSC Pipe |
| 1142 | 200 mm dia AC Pipe |
| 1143 | 250 mm dia AC Pipe |
| 1144 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1145 | PSC Pipes of various sizes |
| 1146 | AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 1147 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1148 | 350 mm MS Pipe |
| 1149 | 400 mm MS Pipe |
| 1150 | 450 mm MS Pipe |
| 1151 | 500 mm MS Pipe |
| 1152 | 600 mm MS Pipe |
| 1153 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 1154 | 350 mm MS Pipe |
| 1155 | 400 mm MS Pipe |
| 1156 | 450 mm MS Pipe |
| 1157 | 500 mm MS Pipe |
| 1158 | 600 mm MS Pipe |
| 1159 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 1160 | 350 mm MS Pipe |
| 1161 | 400 mm MS Pipe |
| 1162 | 450 mm MS Pipe |
| 1163 | 500 mm MS Pipe |
| 1164 | 600 mm MS Pipe |
| 1165 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 1166 | 350 mm MS Pipe |
| 1167 | 400 mm MS Pipe |
| 1168 | 450 mm MS Pipe |
| 1169 | 500 mm MS Pipe |
| 1170 | 600 mm MS Pipe |
| 1171 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 1172 | 350mm MS pipe |
| 1173 | 350mm Machine end |
| 1174 | 400mm MS pipe |
| 1175 | 400mm Machine end |
| 1176 | 450mm MS pipe |
| 1177 | 450mm Machine end |
| 1178 | 500mm MS pipe |
| 1179 | 500mm Machine end |
| 1180 | 600mm MS pipe |
| 1181 | 600mm Machine end |
| 1182 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1183 | 350 mm MS Pipe |
| 1184 | 400 mm MS Pipe |
| 1185 | 450 mm MS Pipe |
| 1186 | 500 mm MS Pipe |
| 1187 | 600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 1188 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1189 | For PVC Pipes of various sizes |
| 1190 | For AC Pipes of various sizes |
| 1191 | For PSC Pipes of various sizes |
| 1192 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 1193 | 50mm PVC 6 KSC |
| 1194 | 63mm PVC 4 KSC |
| 1195 | 75mm PVC 4 KSC |
| 1196 | 90mm PVC 4 KSC |
| 1197 | 110mm PVC 4KSC |
| 1198 | 140mm PVC 4KSC |
| 1199 | 160mm PVC 4KSC |
| 1200 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 1201 | 200 mm AC Pipes Class 15 |
| 1202 | 250 mm AC Pipes Class 15 |
| 1203 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 1204 | 355.6 mm x 4 mm thick MS PIPE |
| 1205 | 406.4 mm x 4 mm thick MS PIPE |
| 1206 | 457 mm x 4 mm thick MS PIPE |
| 1207 | 508 mm x 5 mm thick MS PIPE |
| 1208 | 610 mm x 5.8 mm thick MS PIPE |
| 1209 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 1210 | 50 mm PVC Coupler Fabricated 6 KSC |
| 1211 | 63 mm PVC Coupler Fabricated 4 KSC |
| 1212 | 75 mm PVC Coupler Fabricated 4 KSC |
| 1213 | 90 mm PVC Coupler Fabricated 4 KSC |
| 1214 | 110 mm PVC Coupler Fabricated 4 KSC |
| 1215 | 140 mm PVC Coupler Fabricated 4 KSC |
| 1216 | 160 mm PVC Coupler Fabricated 4 KSC |
| 1217 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 1218 | 200 mm AC Pipes Class 15 |
| 1219 | 250 mm AC Pipes Class 15 |
| 1220 | Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers |
| 1221 | 350 mm dia PSC Pipe |
| 1222 | 400 mm dia PSC Pipe |
| 1223 | 450 mm dia PSC Pipe |
| 1224 | 500 mm dia PSC Pipe |
| 1225 | 600 mm dia PSC Pipe |
| 1226 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 1227 | 50mm PVC 6KSC |
| 1228 | 63mm PVC 4KSC |
| 1229 | 75mm PVC 4KSC |
| 1230 | 90mm PVC 4 KSC |
| 1231 | 110mm PVC 4KSC |
| 1232 | 140mm PVC 4KSC |
| 1233 | 160mm PVC 4KSC |
| 1234 | 200 mm dia AC Class 15 Pipe |
| 1235 | 250 mm dia AC Class 15 Pipe |
| 1236 | 350 mm PSC Pipes |
| 1237 | 400 mm PSC Pipes |
| 1238 | 450 mm PSC Pipes |
| 1239 | 500 mm PSC Pipes |
| 1240 | 600 mm PSC Pipes |
| 1241 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 1242 | 50 mm GI Pipe |
| 1243 | 65 mm GI Pipe |
| 1244 | 80 mm GI Pipe |
| 1245 | 100 mm GI Pipe |
| 1246 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 1247 | 50 mm GI Pipe |
| 1248 | 65 mm GI Pipe |
| 1249 | 80 mm GI Pipe |
| 1250 | 100 mm GI Pipe |
| 1251 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 1252 | 50 mm GI Pipe |
| 1253 | 65 mm GI Pipe |
| 1254 | 80 mm GI Pipe |
| 1255 | 100 mm GI Pipe |
| 1256 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 1257 | 50 mm GI Pipe |
| 1258 | 65 mm GI Pipe |
| 1259 | 80 mm GI Pipe |
| 1260 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 1261 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works |
| 1262 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 1263 | Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 1264 | Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump |
| 1265 | Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor |
| 1266 | Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump |
| 1267 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1268 | Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1269 | Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1270 | Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1271 | Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram |
| 1272 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP |
| 1273 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1274 | Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1275 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai |
| 1276 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar |
| 1277 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room |
| 1278 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar |
| 1279 | Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by ) |
| 1280 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No |
| 1281 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP |
| 1282 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP |
| 1283 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP |
| 1284 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur |
| 1285 | Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump |
| 1286 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump |
| 1287 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump |
| 1288 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP |
| 1289 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi |
| 1290 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti |
| 1291 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump |
| 1292 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump |
| 1293 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar |
| 1294 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump |
| 1295 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump |
| 1296 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP |
| 1297 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur |
| 1298 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump |
| 1299 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP |
| 1300 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu |
| 1301 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump |
| 1302 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump |
| 1303 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu |
| 1304 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump |
| 1305 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump |
| 1306 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump |
| 1307 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump |
| 1308 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump |
| 1309 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room |
| 1310 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 1311 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 1312 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 1313 | Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. |
| 1314 | 3 Pole MCCB |
| 1315 | 32 Amps |
| 1316 | 63 Amps |
| 1317 | 100 Amps |
| 1318 | 150 Amps |
| 1319 | 200 Amps |
| 1320 | 400 Amps |
| 1321 | 600 Amps |
| 1322 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 1323 | 9 Amps\440V |
| 1324 | 12 Amps\440V |
| 1325 | 18 Amps\440V |
| 1326 | 25 Amps\440V |
| 1327 | 140 Amps\440V |
| 1328 | 550 Amps\440V |
| 1329 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 1330 | Upto 5A |
| 1331 | Upto 5A-10A |
| 1332 | Upto 10A-20A |
| 1333 | Upto 50A-75A |
| 1334 | Upto 75A-110A |
| 1335 | Upto 200A-300A |
| 1336 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 1337 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1338 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1339 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1340 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1341 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1342 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1343 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1344 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1345 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1346 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1347 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1348 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1349 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1350 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1351 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1352 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1353 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 1354 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 1355 | For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 1356 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 1357 | 600mm CI sluice valve |
| 1358 | 450 mm CI Sluice valve |
| 1359 | 400 mm CI Sluice valve |
| 1360 | 350 mm CI Sluice valve |
| 1361 | 300 mm CI Scour valve |
| 1362 | 250 mm CI Scour valve |
| 1363 | 200 mm CI scover valve |
| 1364 | 350 mm CI NRV |
| 1365 | 250 mm CI NRV |
| 1366 | 200 mm CI NRV |
| 1367 | 150 mm Double Chamber Air Release Valve |
| 1368 | 100 mm Double Chamber Air Release Valve |
| 1369 | 80 mm Double Chamber Air Release Valve |
| 1370 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 1371 | 50 mm Gate valve |
| 1372 | 65 mm Gate valve |
| 1373 | 80 mm Gate valve |
| 1374 | 100 mm Gate valve |
| 1375 | Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty |
| 1376 | 50 mm Single chamber air release Valve |
| 1377 | 80 mm Single chamber air release Valve |
| 1378 | 100 mm Single chamber air release Valve |
| 1379 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 1380 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 1381 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 1382 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 1383 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 1384 | 6.00 LL capacity of sump @ head works, Veikalipatti, Kavoor |
| 1385 | 4.00 LL capacity of sump @ Mathalamparai, Vanjinagar |
| 1386 | 2.00 LL capacity of sump @ Panozhi |
| 1387 | 1.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram |
| 1388 | 0.70 LL capacity of sump @ Melapavoor |
| 1389 | 0.45 LL capacity of sump @ Kulasekarapatti |
| 1390 | 0.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani |
| 1391 | 0.20 LL capacity of sump @ PP Valasai, Pattakurichi |
| 1392 | 0.15 LL capacity of sump @ Anna nagar, Parumbu |
| 1393 | Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI) |
| 1394 | Inflitration well 1 to 8 Nos- Each-8 Hours For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 1395 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3044.1 ML (8.34*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 1396 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1397 | PSC Pipes of various sizes |
| 1398 | AC Pipes of various sizes |
| 1399 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1400 | 350 mm dia PSC Pipe |
| 1401 | 400 mm dia PSC Pipe |
| 1402 | 450 mm dia PSC Pipe |
| 1403 | 500 mm dia PSC Pipe |
| 1404 | 600 mm dia PSC Pipe |
| 1405 | 200 mm dia AC Pipe |
| 1406 | 250 mm dia AC Pipe |
| 1407 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1408 | 350 mm dia PSC Pipe |
| 1409 | 400 mm dia PSC Pipe |
| 1410 | 450 mm dia PSC Pipe |
| 1411 | 500 mm dia PSC Pipe |
| 1412 | 600 mm dia PSC Pipe |
| 1413 | 200 mm dia AC Pipe |
| 1414 | 250 mm dia AC Pipe |
| 1415 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 1416 | 350 mm dia PSC Pipe |
| 1417 | 400 mm dia PSC Pipe |
| 1418 | 450 mm dia PSC Pipe |
| 1419 | 500 mm dia PSC Pipe |
| 1420 | 600 mm dia PSC Pipe |
| 1421 | 200 mm dia AC Pipe |
| 1422 | 250 mm dia AC Pipe |
| 1423 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 1424 | 350 mm dia PSC Pipe |
| 1425 | 400 mm dia PSC Pipe |
| 1426 | 450 mm dia PSC Pipe |
| 1427 | 500 mm dia PSC Pipe |
| 1428 | 600 mm dia PSC Pipe |
| 1429 | 200 mm dia AC Pipe |
| 1430 | 250 mm dia AC Pipe |
| 1431 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1432 | PSC Pipes of various sizes |
| 1433 | AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 1434 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1435 | 350 mm MS Pipe |
| 1436 | 400 mm MS Pipe |
| 1437 | 450 mm MS Pipe |
| 1438 | 500 mm MS Pipe |
| 1439 | 600 mm MS Pipe |
| 1440 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 1441 | 350 mm MS Pipe |
| 1442 | 400 mm MS Pipe |
| 1443 | 450 mm MS Pipe |
| 1444 | 500 mm MS Pipe |
| 1445 | 600 mm MS Pipe |
| 1446 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 1447 | 350 mm MS Pipe |
| 1448 | 400 mm MS Pipe |
| 1449 | 450 mm MS Pipe |
| 1450 | 500 mm MS Pipe |
| 1451 | 600 mm MS Pipe |
| 1452 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 1453 | 350 mm MS Pipe |
| 1454 | 400 mm MS Pipe |
| 1455 | 450 mm MS Pipe |
| 1456 | 500 mm MS Pipe |
| 1457 | 600 mm MS Pipe |
| 1458 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 1459 | 350mm MS pipe |
| 1460 | 350mm Machine end |
| 1461 | 400mm MS pipe |
| 1462 | 400mm Machine end |
| 1463 | 450mm MS pipe |
| 1464 | 450mm Machine end |
| 1465 | 500mm MS pipe |
| 1466 | 500mm Machine end |
| 1467 | 600mm MS pipe |
| 1468 | 600mm Machine end |
| 1469 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1470 | 350 mm MS Pipe |
| 1471 | 400 mm MS Pipe |
| 1472 | 450 mm MS Pipe |
| 1473 | 500 mm MS Pipe |
| 1474 | 600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 1475 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1476 | For PVC Pipes of various sizes |
| 1477 | For AC Pipes of various sizes |
| 1478 | For PSC Pipes of various sizes |
| 1479 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 1480 | 50mm PVC 6 KSC |
| 1481 | 63mm PVC 4 KSC |
| 1482 | 75mm PVC 4 KSC |
| 1483 | 90mm PVC 4 KSC |
| 1484 | 110mm PVC 4KSC |
| 1485 | 140mm PVC 4KSC |
| 1486 | 160mm PVC 4KSC |
| 1487 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 1488 | 200 mm AC Pipes Class 15 |
| 1489 | 250 mm AC Pipes Class 15 |
| 1490 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 1491 | 355.6 mm x 4 mm thick MS PIPE |
| 1492 | 406.4 mm x 4 mm thick MS PIPE |
| 1493 | 457 mm x 4 mm thick MS PIPE |
| 1494 | 508 mm x 5 mm thick MS PIPE |
| 1495 | 610 mm x 5.8 mm thick MS PIPE |
| 1496 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 1497 | 50 mm PVC Coupler Fabricated 6 KSC |
| 1498 | 63 mm PVC Coupler Fabricated 4 KSC |
| 1499 | 75 mm PVC Coupler Fabricated 4 KSC |
| 1500 | 90 mm PVC Coupler Fabricated 4 KSC |
| 1501 | 110 mm PVC Coupler Fabricated 4 KSC |
| 1502 | 140 mm PVC Coupler Fabricated 4 KSC |
| 1503 | 160 mm PVC Coupler Fabricated 4 KSC |
| 1504 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 1505 | 200 mm AC Pipes Class 15 |
| 1506 | 250 mm AC Pipes Class 15 |
| 1507 | Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers |
| 1508 | 350 mm dia PSC Pipe |
| 1509 | 400 mm dia PSC Pipe |
| 1510 | 450 mm dia PSC Pipe |
| 1511 | 500 mm dia PSC Pipe |
| 1512 | 600 mm dia PSC Pipe |
| 1513 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 1514 | 50mm PVC 6KSC |
| 1515 | 63mm PVC 4KSC |
| 1516 | 75mm PVC 4KSC |
| 1517 | 90mm PVC 4 KSC |
| 1518 | 110mm PVC 4KSC |
| 1519 | 140mm PVC 4KSC |
| 1520 | 160mm PVC 4KSC |
| 1521 | 200 mm dia AC Class 15 Pipe |
| 1522 | 250 mm dia AC Class 15 Pipe |
| 1523 | 350 mm PSC Pipes |
| 1524 | 400 mm PSC Pipes |
| 1525 | 450 mm PSC Pipes |
| 1526 | 500 mm PSC Pipes |
| 1527 | 600 mm PSC Pipes |
| 1528 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 1529 | 50 mm GI Pipe |
| 1530 | 65 mm GI Pipe |
| 1531 | 80 mm GI Pipe |
| 1532 | 100 mm GI Pipe |
| 1533 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 1534 | 50 mm GI Pipe |
| 1535 | 65 mm GI Pipe |
| 1536 | 80 mm GI Pipe |
| 1537 | 100 mm GI Pipe |
| 1538 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 1539 | 50 mm GI Pipe |
| 1540 | 65 mm GI Pipe |
| 1541 | 80 mm GI Pipe |
| 1542 | 100 mm GI Pipe |
| 1543 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 1544 | 50 mm GI Pipe |
| 1545 | 65 mm GI Pipe |
| 1546 | 80 mm GI Pipe |
| 1547 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 1548 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works |
| 1549 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 1550 | Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 1551 | Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump |
| 1552 | Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor |
| 1553 | Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump |
| 1554 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1555 | Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1556 | Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1557 | Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1558 | Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram |
| 1559 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP |
| 1560 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1561 | Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1562 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai |
| 1563 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar |
| 1564 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room |
| 1565 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar |
| 1566 | Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by ) |
| 1567 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No |
| 1568 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP |
| 1569 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP |
| 1570 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP |
| 1571 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur |
| 1572 | Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump |
| 1573 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump |
| 1574 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump |
| 1575 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP |
| 1576 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi |
| 1577 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti |
| 1578 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump |
| 1579 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump |
| 1580 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar |
| 1581 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump |
| 1582 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump |
| 1583 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP |
| 1584 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur |
| 1585 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump |
| 1586 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP |
| 1587 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu |
| 1588 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump |
| 1589 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump |
| 1590 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu |
| 1591 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump |
| 1592 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump |
| 1593 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump |
| 1594 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump |
| 1595 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump |
| 1596 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai |
| 1597 | Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room |
| 1598 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 1599 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 1600 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 1601 | Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. |
| 1602 | 3 Pole MCCB |
| 1603 | 32 Amps |
| 1604 | 63 Amps |
| 1605 | 100 Amps |
| 1606 | 150 Amps |
| 1607 | 200 Amps |
| 1608 | 400 Amps |
| 1609 | 600 Amps |
| 1610 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 1611 | 9 Amps\440V |
| 1612 | 12 Amps\440V |
| 1613 | 18 Amps\440V |
| 1614 | 25 Amps\440V |
| 1615 | 140 Amps\440V |
| 1616 | 550 Amps\440V |
| 1617 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 1618 | Upto 5A |
| 1619 | Upto 5A-10A |
| 1620 | Upto 10A-20A |
| 1621 | Upto 50A-75A |
| 1622 | Upto 75A-110A |
| 1623 | Upto 200A-300A |
| 1624 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 1625 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1626 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1627 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1628 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1629 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1630 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1631 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1632 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1633 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1634 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1635 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1636 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1637 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1638 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1639 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1640 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1641 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 1642 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 1643 | For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 1644 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 1645 | 600mm CI sluice valve |
| 1646 | 450 mm CI Sluice valve |
| 1647 | 400 mm CI Sluice valve |
| 1648 | 350 mm CI Sluice valve |
| 1649 | 300 mm CI Scour valve |
| 1650 | 250 mm CI Scour valve |
| 1651 | 200 mm CI scover valve |
| 1652 | 350 mm CI NRV |
| 1653 | 250 mm CI NRV |
| 1654 | 200 mm CI NRV |
| 1655 | 150 mm Double Chamber Air Release Valve |
| 1656 | 100 mm Double Chamber Air Release Valve |
| 1657 | 80 mm Double Chamber Air Release Valve |
| 1658 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 1659 | 50 mm Gate valve |
| 1660 | 65 mm Gate valve |
| 1661 | 80 mm Gate valve |
| 1662 | 100 mm Gate valve |
| 1663 | Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty |
| 1664 | 50 mm Single chamber air release Valve |
| 1665 | 80 mm Single chamber air release Valve |
| 1666 | 100 mm Single chamber air release Valve |
| 1667 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 1668 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 1669 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 1670 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 1671 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 1672 | 6.00 LL capacity of sump @ head works, Veikalipatti, Kavoor |
| 1673 | 4.00 LL capacity of sump @ Mathalamparai, Vanjinagar |
| 1674 | 2.00 LL capacity of sump @ Panozhi |
| 1675 | 1.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram |
| 1676 | 0.70 LL capacity of sump @ Melapavoor |
| 1677 | 0.45 LL capacity of sump @ Kulasekarapatti |
| 1678 | 0.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani |
| 1679 | 0.20 LL capacity of sump @ PP Valasai, Pattakurichi |
| 1680 | 0.15 LL capacity of sump @ Anna nagar, Parumbu |
| 1681 | Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI) |
| 1682 | Inflitration well 1 to 8 Nos- Each-8 Hours For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 1683 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3044.1 ML (8.34*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 1684 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1685 | PSC Pipes of various sizes |
| 1686 | AC Pipes of various sizes |
| 1687 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1688 | 350 mm dia PSC Pipe |
| 1689 | 400 mm dia PSC Pipe |
| 1690 | 450 mm dia PSC Pipe |
| 1691 | 500 mm dia PSC Pipe |
| 1692 | 600 mm dia PSC Pipe |
| 1693 | 200 mm dia AC Pipe |
| 1694 | 250 mm dia AC Pipe |
| 1695 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1696 | 350 mm dia PSC Pipe |
| 1697 | 400 mm dia PSC Pipe |
| 1698 | 450 mm dia PSC Pipe |
| 1699 | 500 mm dia PSC Pipe |
| 1700 | 600 mm dia PSC Pipe |
| 1701 | 200 mm dia AC Pipe |
| 1702 | 250 mm dia AC Pipe |
| 1703 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 1704 | 350 mm dia PSC Pipe |
| 1705 | 400 mm dia PSC Pipe |
| 1706 | 450 mm dia PSC Pipe |
| 1707 | 500 mm dia PSC Pipe |
| 1708 | 600 mm dia PSC Pipe |
| 1709 | 200 mm dia AC Pipe |
| 1710 | 250 mm dia AC Pipe |
| 1711 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 1712 | 350 mm dia PSC Pipe |
| 1713 | 400 mm dia PSC Pipe |
| 1714 | 450 mm dia PSC Pipe |
| 1715 | 500 mm dia PSC Pipe |
| 1716 | 600 mm dia PSC Pipe |
| 1717 | 200 mm dia AC Pipe |
| 1718 | 250 mm dia AC Pipe |
| 1719 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1720 | PSC Pipes of various sizes |
| 1721 | AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers |
| 1722 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1723 | 350 mm MS Pipe |
| 1724 | 400 mm MS Pipe |
| 1725 | 450 mm MS Pipe |
| 1726 | 500 mm MS Pipe |
| 1727 | 600 mm MS Pipe |
| 1728 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 1729 | 350 mm MS Pipe |
| 1730 | 400 mm MS Pipe |
| 1731 | 450 mm MS Pipe |
| 1732 | 500 mm MS Pipe |
| 1733 | 600 mm MS Pipe |
| 1734 | Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges. |
| 1735 | 350 mm MS Pipe |
| 1736 | 400 mm MS Pipe |
| 1737 | 450 mm MS Pipe |
| 1738 | 500 mm MS Pipe |
| 1739 | 600 mm MS Pipe |
| 1740 | Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers. |
| 1741 | 350 mm MS Pipe |
| 1742 | 400 mm MS Pipe |
| 1743 | 450 mm MS Pipe |
| 1744 | 500 mm MS Pipe |
| 1745 | 600 mm MS Pipe |
| 1746 | Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 1747 | 350mm MS pipe |
| 1748 | 350mm Machine end |
| 1749 | 400mm MS pipe |
| 1750 | 400mm Machine end |
| 1751 | 450mm MS pipe |
| 1752 | 450mm Machine end |
| 1753 | 500mm MS pipe |
| 1754 | 500mm Machine end |
| 1755 | 600mm MS pipe |
| 1756 | 600mm Machine end |
| 1757 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1758 | 350 mm MS Pipe |
| 1759 | 400 mm MS Pipe |
| 1760 | 450 mm MS Pipe |
| 1761 | 500 mm MS Pipe |
| 1762 | 600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 1763 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1764 | For PVC Pipes of various sizes |
| 1765 | For AC Pipes of various sizes |
| 1766 | For PSC Pipes of various sizes |
| 1767 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 1768 | 50mm PVC 6 KSC |
| 1769 | 63mm PVC 4 KSC |
| 1770 | 75mm PVC 4 KSC |
| 1771 | 90mm PVC 4 KSC |
| 1772 | 110mm PVC 4KSC |
| 1773 | 140mm PVC 4KSC |
| 1774 | 160mm PVC 4KSC |
| 1775 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 1776 | 200 mm AC Pipes Class 15 |
| 1777 | 250 mm AC Pipes Class 15 |
| 1778 | Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 1779 | 355.6 mm x 4 mm thick MS PIPE |
| 1780 | 406.4 mm x 4 mm thick MS PIPE |
| 1781 | 457 mm x 4 mm thick MS PIPE |
| 1782 | 508 mm x 5 mm thick MS PIPE |
| 1783 | 610 mm x 5.8 mm thick MS PIPE |
| 1784 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 1785 | 50 mm PVC Coupler Fabricated 6 KSC |
| 1786 | 63 mm PVC Coupler Fabricated 4 KSC |
| 1787 | 75 mm PVC Coupler Fabricated 4 KSC |
| 1788 | 90 mm PVC Coupler Fabricated 4 KSC |
| 1789 | 110 mm PVC Coupler Fabricated 4 KSC |
| 1790 | 140 mm PVC Coupler Fabricated 4 KSC |
| 1791 | 160 mm PVC Coupler Fabricated 4 KSC |
| 1792 | Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers |
| 1793 | 200 mm AC Pipes Class 15 |
| 1794 | 250 mm AC Pipes Class 15 |
| 1795 | Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers |
| 1796 | 350 mm dia PSC Pipe |
| 1797 | 400 mm dia PSC Pipe |
| 1798 | 450 mm dia PSC Pipe |
| 1799 | 500 mm dia PSC Pipe |
| 1800 | 600 mm dia PSC Pipe |
| 1801 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 1802 | 50mm PVC 6KSC |
| 1803 | 63mm PVC 4KSC |
| 1804 | 75mm PVC 4KSC |
| 1805 | 90mm PVC 4 KSC |
| 1806 | 110mm PVC 4KSC |
| 1807 | 140mm PVC 4KSC |
| 1808 | 160mm PVC 4KSC |
| 1809 | 200 mm dia AC Class 15 Pipe |
| 1810 | 250 mm dia AC Class 15 Pipe |
| 1811 | 350 mm PSC Pipes |
| 1812 | 400 mm PSC Pipes |
| 1813 | 450 mm PSC Pipes |
| 1814 | 500 mm PSC Pipes |
| 1815 | 600 mm PSC Pipes |
| 1816 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 1817 | 50 mm GI Pipe |
| 1818 | 65 mm GI Pipe |
| 1819 | 80 mm GI Pipe |
| 1820 | 100 mm GI Pipe |
| 1821 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 1822 | 50 mm GI Pipe |
| 1823 | 65 mm GI Pipe |
| 1824 | 80 mm GI Pipe |
| 1825 | 100 mm GI Pipe |
| 1826 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 1827 | 50 mm GI Pipe |
| 1828 | 65 mm GI Pipe |
| 1829 | 80 mm GI Pipe |
| 1830 | 100 mm GI Pipe |
| 1831 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 1832 | 50 mm GI Pipe |
| 1833 | 65 mm GI Pipe |
| 1834 | 80 mm GI Pipe |
| 1835 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 1836 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works |
| 1837 | Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 1838 | Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works |
| 1839 | Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump |
| 1840 | Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor |
| 1841 | Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump |
| 1842 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1843 | Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1844 | Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1845 | Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti |
| 1846 | Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram |
| 1847 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP |
| 1848 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1849 | Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai |
| 1850 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai |
| 1851 | Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar |
| 1852 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room |
| 1853 | Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar |
| 1854 | Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by ) |
| 1855 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No |
| 1856 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP |
| 1857 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP |
| 1858 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP |
| 1859 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur |
| 1860 | Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump |
| 1861 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump |
| 1862 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump |
| 1863 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP |
| 1864 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi |
| 1865 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti |
| 1866 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump |
| 1867 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump |
| 1868 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar |
| 1869 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump |
| 1870 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump |
| 1871 | Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP |
| 1872 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur |
| 1873 | Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump |
| 1874 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP |
| 1875 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu |
| 1876 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump |
| 1877 | Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump |
| 1878 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu |
| 1879 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump |
| 1880 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump |
| 1881 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump |
| 1882 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump |
| 1883 | Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump |
| 1884 | Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai |
| 1885 | Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room |
| 1886 | Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 1887 | Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 1888 | Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 1889 | Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. |
| 1890 | 3 Pole MCCB |
| 1891 | 32 Amps |
| 1892 | 63 Amps |
| 1893 | 100 Amps |
| 1894 | 150 Amps |
| 1895 | 200 Amps |
| 1896 | 400 Amps |
| 1897 | 600 Amps |
| 1898 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 1899 | 9 Amps\440V |
| 1900 | 12 Amps\440V |
| 1901 | 18 Amps\440V |
| 1902 | 25 Amps\440V |
| 1903 | 140 Amps\440V |
| 1904 | 550 Amps\440V |
| 1905 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 1906 | Upto 5A |
| 1907 | Upto 5A-10A |
| 1908 | Upto 10A-20A |
| 1909 | Upto 50A-75A |
| 1910 | Upto 75A-110A |
| 1911 | Upto 200A-300A |
| 1912 | Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply |
| 1913 | Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1914 | Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1915 | Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1916 | Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1917 | Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1918 | Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1919 | Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1920 | Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1921 | Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1922 | Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1923 | Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1924 | Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1925 | Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1926 | Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1927 | Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers |
| 1928 | Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers |
| 1929 | Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers |
| 1930 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 1931 | For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 1932 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 1933 | 600mm CI sluice valve |
| 1934 | 450 mm CI Sluice valve |
| 1935 | 400 mm CI Sluice valve |
| 1936 | 350 mm CI Sluice valve |
| 1937 | 300 mm CI Scour valve |
| 1938 | 250 mm CI Scour valve |
| 1939 | 200 mm CI scover valve |
| 1940 | 350 mm CI NRV |
| 1941 | 250 mm CI NRV |
| 1942 | 200 mm CI NRV |
| 1943 | 150 mm Double Chamber Air Release Valve |
| 1944 | 100 mm Double Chamber Air Release Valve |
| 1945 | 80 mm Double Chamber Air Release Valve |
| 1946 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 1947 | 50 mm Gate valve |
| 1948 | 65 mm Gate valve |
| 1949 | 80 mm Gate valve |
| 1950 | 100 mm Gate valve |
| 1951 | Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty |
| 1952 | 50 mm Single chamber air release Valve |
| 1953 | 80 mm Single chamber air release Valve |
| 1954 | 100 mm Single chamber air release Valve |
| 1955 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 1956 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 1957 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 1958 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 1959 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 1960 | 6.00 LL capacity of sump @ head works, Veikalipatti, Kavoor |
| 1961 | 4.00 LL capacity of sump @ Mathalamparai, Vanjinagar |
| 1962 | 2.00 LL capacity of sump @ Panozhi |
| 1963 | 1.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram |
| 1964 | 0.70 LL capacity of sump @ Melapavoor |
| 1965 | 0.45 LL capacity of sump @ Kulasekarapatti |
| 1966 | 0.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani |
| 1967 | 0.20 LL capacity of sump @ PP Valasai, Pattakurichi |
| 1968 | 0.15 LL capacity of sump @ Anna nagar, Parumbu |
| 1969 | Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI) |
| 1970 | Inflitration well 1 to 8 Nos- Each-8 Hours |
| 1971 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 1972 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 222.30 ML (2.47*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 1973 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1974 | 300 mm dia CI Pipe |
| 1975 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1976 | 300 mm dia CI Pipe |
| 1977 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 1978 | 300 mm dia CI Pipe |
| 1979 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 1980 | 300 mm dia CI Pipe |
| 1981 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 1982 | 300 mm dia CI Pipe |
| 1983 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1984 | 300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 1985 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 1986 | 300 mm dia CI Pipe |
| 1987 | 90mm PVC Pipe |
| 1988 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 1989 | 90mm PVC 4 KSC |
| 1990 | Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 1991 | 300 mm DI Pipe |
| 1992 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 1993 | 90 mm PVC Coupler Fabricated 4 KSC |
| 1994 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 1995 | 300 mm DI Pipe |
| 1996 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 1997 | 300 mm DI Pipe |
| 1998 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 1999 | 300 mm DI Pipe |
| 2000 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2001 | 90mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS |
| 2002 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2003 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No ) |
| 2004 | Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram ) |
| 2005 | Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2006 | Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2007 | Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram |
| 2008 | Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos |
| 2009 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2010 | 9 Amps\440V |
| 2011 | 12 Amps\440V |
| 2012 | 25 Amps\440V |
| 2013 | 50 Amps\440V |
| 2014 | 95 Amps\440V |
| 2015 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2016 | Upto 5A |
| 2017 | Upto 5A-10A |
| 2018 | Upto 20A-30A |
| 2019 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2020 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2021 | 300mm CI sluice valve |
| 2022 | 150 mm CI Sluice valve |
| 2023 | 100 mm CI Sluice valve |
| 2024 | 80 mm CI Sluice valve |
| 2025 | 150 mm CI NRV valve |
| 2026 | 100 mm CI NRV valve |
| 2027 | 80 mm CI NRV valve |
| 2028 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2029 | 50 mm Gate valve |
| 2030 | 65 mm Gate valve |
| 2031 | 80 mm Gate valve |
| 2032 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2033 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2034 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2035 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2036 | 1.25 LL capacity of sump @Kudiyarppu Clearing light jungle |
| 2037 | Around SS Tank @ Kudiyarppu |
| 2038 | Office Campus @Kudiyarppu |
| 2039 | Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure ) For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 2040 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 901.55 ML (2.47*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2041 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2042 | 300 mm dia CI Pipe |
| 2043 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2044 | 300 mm dia CI Pipe |
| 2045 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2046 | 300 mm dia CI Pipe |
| 2047 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2048 | 300 mm dia CI Pipe |
| 2049 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2050 | 300 mm dia CI Pipe |
| 2051 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2052 | 300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2053 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2054 | 300 mm dia CI Pipe |
| 2055 | 90mm PVC Pipe |
| 2056 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2057 | 90mm PVC 4 KSC |
| 2058 | Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 2059 | 300 mm DI Pipe |
| 2060 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2061 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2062 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2063 | 300 mm DI Pipe |
| 2064 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 2065 | 300 mm DI Pipe |
| 2066 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2067 | 300 mm DI Pipe |
| 2068 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2069 | 90mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS |
| 2070 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2071 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No ) |
| 2072 | Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram ) |
| 2073 | Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2074 | Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2075 | Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram |
| 2076 | Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos |
| 2077 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2078 | 9 Amps\440V |
| 2079 | 12 Amps\440V |
| 2080 | 25 Amps\440V |
| 2081 | 50 Amps\440V |
| 2082 | 95 Amps\440V |
| 2083 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2084 | Upto 5A |
| 2085 | Upto 5A-10A |
| 2086 | Upto 20A-30A |
| 2087 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2088 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2089 | 300mm CI sluice valve |
| 2090 | 150 mm CI Sluice valve |
| 2091 | 100 mm CI Sluice valve |
| 2092 | 80 mm CI Sluice valve |
| 2093 | 150 mm CI NRV valve |
| 2094 | 100 mm CI NRV valve |
| 2095 | 80 mm CI NRV valve |
| 2096 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2097 | 50 mm Gate valve |
| 2098 | 65 mm Gate valve |
| 2099 | 80 mm Gate valve |
| 2100 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2101 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2102 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2103 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2104 | 1.25 LL capacity of sump @Kudiyarppu Clearing light jungle |
| 2105 | Around SS Tank @ Kudiyarppu |
| 2106 | Office Campus @Kudiyarppu |
| 2107 | Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure ) For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 2108 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 901.55 ML (2.47*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2109 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2110 | 300 mm dia CI Pipe |
| 2111 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2112 | 300 mm dia CI Pipe |
| 2113 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2114 | 300 mm dia CI Pipe |
| 2115 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2116 | 300 mm dia CI Pipe |
| 2117 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2118 | 300 mm dia CI Pipe |
| 2119 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2120 | 300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2121 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2122 | 300 mm dia CI Pipe |
| 2123 | 90mm PVC Pipe |
| 2124 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2125 | 90mm PVC 4 KSC |
| 2126 | Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 2127 | 300 mm DI Pipe |
| 2128 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2129 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2130 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2131 | 300 mm DI Pipe |
| 2132 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 2133 | 300 mm DI Pipe |
| 2134 | Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2135 | 300 mm DI Pipe |
| 2136 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2137 | 90mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS |
| 2138 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2139 | Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No ) |
| 2140 | Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram ) |
| 2141 | Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2142 | Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam ) |
| 2143 | Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram |
| 2144 | Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos |
| 2145 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2146 | 12 Amps\440V |
| 2147 | 25 Amps\440V |
| 2148 | 50 Amps\440V |
| 2149 | 95 Amps\440V |
| 2150 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2151 | Upto 5A |
| 2152 | Upto 5A-10A |
| 2153 | Upto 20A-30A |
| 2154 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2155 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2156 | 300mm CI sluice valve |
| 2157 | 150 mm CI Sluice valve |
| 2158 | 100 mm CI Sluice valve |
| 2159 | 80 mm CI Sluice valve |
| 2160 | 150 mm CI NRV valve |
| 2161 | 100 mm CI NRV valve |
| 2162 | 80 mm CI NRV valve |
| 2163 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2164 | 50 mm Gate valve |
| 2165 | 65 mm Gate valve |
| 2166 | 80 mm Gate valve |
| 2167 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2168 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2169 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2170 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2171 | 1.25 LL capacity of sump @Kudiyarppu Clearing light jungle |
| 2172 | Around SS Tank @ Kudiyarppu |
| 2173 | Office Campus @Kudiyarppu |
| 2174 | Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure ) |
| 2175 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2176 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2177 | AC Pipes of various sizes |
| 2178 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2179 | 200 mm AC of Various Classes |
| 2180 | 250 mm AC of Various Classes |
| 2181 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2182 | 200 mm AC of Various Classes |
| 2183 | 250 mm AC of Various Classes |
| 2184 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2185 | 200 mm AC of Various Classes |
| 2186 | 250 mm AC of Various Classes |
| 2187 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2188 | 200 mm AC of Various Classes |
| 2189 | 250 mm AC of Various Classes |
| 2190 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2191 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2192 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2193 | For PVC Pipes of various sizes |
| 2194 | For AC Pipes of various sizes |
| 2195 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2196 | 50mm PVC 6KSC |
| 2197 | 63mm PVC 4KSC |
| 2198 | 75mm PVC 4KSC |
| 2199 | 90mm PVC 4 KSC |
| 2200 | 110mm PVC 4KSC |
| 2201 | 140mm PVC 4KSC |
| 2202 | 160mm PVC 4KSC |
| 2203 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 2204 | 200 mm AC Pipe Class 15 |
| 2205 | 250 mm AC Pipe Class 15 |
| 2206 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2207 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2208 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2209 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2210 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2211 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2212 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2213 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2214 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2215 | 200 mm AC Pipe Class 15 |
| 2216 | 250 mm AC Pipe Class 15 |
| 2217 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2218 | 50mm PVC 6KSC |
| 2219 | 63mm PVC 4KSC |
| 2220 | 75mm PVC 4KSC |
| 2221 | 90mm PVC 4 KSC |
| 2222 | 110mm PVC 4KSC |
| 2223 | 140mm PVC 4KSC |
| 2224 | 160mm PVC 4KSC |
| 2225 | 200 mm AC Pipe Class 15 |
| 2226 | 250 mm AC Pipe Class 15 |
| 2227 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2228 | 50 mm GI Pipe |
| 2229 | 65 mm GI Pipe |
| 2230 | 80 mm GI Pipe |
| 2231 | 100 mm GI Pipe |
| 2232 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2233 | 50 mm GI Pipe |
| 2234 | 65 mm GI Pipe |
| 2235 | 80 mm GI Pipe |
| 2236 | 100 mm GI Pipe |
| 2237 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2238 | 50 mm GI Pipe |
| 2239 | 65 mm GI Pipe |
| 2240 | 80 mm GI Pipe |
| 2241 | 100 mm GI Pipe |
| 2242 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2243 | 50 mm GI Pipe |
| 2244 | 65 mm GI Pipe |
| 2245 | 80 mm GI Pipe |
| 2246 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2247 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2248 | Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2249 | Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2250 | Vadamalaipatti Booster Station |
| 2251 | Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam ) |
| 2252 | Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti |
| 2253 | Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam |
| 2254 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2255 | 9 Amps\440V |
| 2256 | 12 Amps\440V |
| 2257 | 25 Amps\440V |
| 2258 | 45 Amps\440V |
| 2259 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2260 | Upto 5A |
| 2261 | Upto 5A-10A |
| 2262 | Upto 20A-30A |
| 2263 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2264 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2265 | 150mm CI sluice valve |
| 2266 | 150 mm CI NRV |
| 2267 | 100 mm CI NRV |
| 2268 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2269 | 50 mm Gate valve |
| 2270 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 2271 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2272 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2273 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2274 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2275 | 0.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai For the year 2027-28 (From 01.04.2027 to 31.03.2028) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2276 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2277 | AC Pipes of various sizes |
| 2278 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2279 | 200 mm AC of Various Classes |
| 2280 | 250 mm AC of Various Classes |
| 2281 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2282 | 200 mm AC of Various Classes |
| 2283 | 250 mm AC of Various Classes |
| 2284 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2285 | 200 mm AC of Various Classes |
| 2286 | 250 mm AC of Various Classes |
| 2287 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2288 | 200 mm AC of Various Classes |
| 2289 | 250 mm AC of Various Classes |
| 2290 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2291 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2292 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2293 | For PVC Pipes of various sizes |
| 2294 | For AC Pipes of various sizes |
| 2295 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2296 | 50mm PVC 6KSC |
| 2297 | 63mm PVC 4KSC |
| 2298 | 75mm PVC 4KSC |
| 2299 | 90mm PVC 4 KSC |
| 2300 | 110mm PVC 4KSC |
| 2301 | 140mm PVC 4KSC |
| 2302 | 160mm PVC 4KSC |
| 2303 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 2304 | 200 mm AC Pipe Class 15 |
| 2305 | 250 mm AC Pipe Class 15 |
| 2306 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2307 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2308 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2309 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2310 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2311 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2312 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2313 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2314 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2315 | 200 mm AC Pipe Class 15 |
| 2316 | 250 mm AC Pipe Class 15 |
| 2317 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2318 | 50mm PVC 6KSC |
| 2319 | 63mm PVC 4KSC |
| 2320 | 75mm PVC 4KSC |
| 2321 | 90mm PVC 4 KSC |
| 2322 | 110mm PVC 4KSC |
| 2323 | 140mm PVC 4KSC |
| 2324 | 160mm PVC 4KSC |
| 2325 | 200 mm AC Pipe Class 15 |
| 2326 | 250 mm AC Pipe Class 15 |
| 2327 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2328 | 50 mm GI Pipe |
| 2329 | 65 mm GI Pipe |
| 2330 | 80 mm GI Pipe |
| 2331 | 100 mm GI Pipe |
| 2332 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2333 | 50 mm GI Pipe |
| 2334 | 65 mm GI Pipe |
| 2335 | 80 mm GI Pipe |
| 2336 | 100 mm GI Pipe |
| 2337 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2338 | 50 mm GI Pipe |
| 2339 | 65 mm GI Pipe |
| 2340 | 80 mm GI Pipe |
| 2341 | 100 mm GI Pipe |
| 2342 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2343 | 50 mm GI Pipe |
| 2344 | 65 mm GI Pipe |
| 2345 | 80 mm GI Pipe |
| 2346 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2347 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2348 | Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2349 | Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2350 | Vadamalaipatti Booster Station |
| 2351 | Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam ) |
| 2352 | Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti |
| 2353 | Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam |
| 2354 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2355 | 9 Amps\440V |
| 2356 | 12 Amps\440V |
| 2357 | 25 Amps\440V |
| 2358 | 45 Amps\440V |
| 2359 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2360 | Upto 5A |
| 2361 | Upto 5A-10A |
| 2362 | Upto 20A-30A |
| 2363 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2364 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2365 | 150mm CI sluice valve |
| 2366 | 150 mm CI NRV |
| 2367 | 100 mm CI NRV |
| 2368 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2369 | 50 mm Gate valve |
| 2370 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 2371 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2372 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2373 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2374 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2375 | 0.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai For the year 2028-29 (From 01.04.2028 to 31.03.2029) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2376 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2377 | AC Pipes of various sizes |
| 2378 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2379 | 200 mm AC of Various Classes |
| 2380 | 250 mm AC of Various Classes |
| 2381 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2382 | 200 mm AC of Various Classes |
| 2383 | 250 mm AC of Various Classes |
| 2384 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2385 | 200 mm AC of Various Classes |
| 2386 | 250 mm AC of Various Classes |
| 2387 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2388 | 200 mm AC of Various Classes |
| 2389 | 250 mm AC of Various Classes |
| 2390 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2391 | AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2392 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2393 | For PVC Pipes of various sizes |
| 2394 | For AC Pipes of various sizes |
| 2395 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2396 | 50mm PVC 6KSC |
| 2397 | 63mm PVC 4KSC |
| 2398 | 75mm PVC 4KSC |
| 2399 | 90mm PVC 4 KSC |
| 2400 | 110mm PVC 4KSC |
| 2401 | 140mm PVC 4KSC |
| 2402 | 160mm PVC 4KSC |
| 2403 | Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers. |
| 2404 | 200 mm AC Pipe Class 15 |
| 2405 | 250 mm AC Pipe Class 15 |
| 2406 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2407 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2408 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2409 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2410 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2411 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2412 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2413 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2414 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2415 | 200 mm AC Pipe Class 15 |
| 2416 | 250 mm AC Pipe Class 15 |
| 2417 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2418 | 50mm PVC 6KSC |
| 2419 | 63mm PVC 4KSC |
| 2420 | 75mm PVC 4KSC |
| 2421 | 90mm PVC 4 KSC |
| 2422 | 110mm PVC 4KSC |
| 2423 | 140mm PVC 4KSC |
| 2424 | 160mm PVC 4KSC |
| 2425 | 200 mm AC Pipe Class 15 |
| 2426 | 250 mm AC Pipe Class 15 |
| 2427 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2428 | 50 mm GI Pipe |
| 2429 | 65 mm GI Pipe |
| 2430 | 80 mm GI Pipe |
| 2431 | 100 mm GI Pipe |
| 2432 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2433 | 50 mm GI Pipe |
| 2434 | 65 mm GI Pipe |
| 2435 | 80 mm GI Pipe |
| 2436 | 100 mm GI Pipe |
| 2437 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2438 | 50 mm GI Pipe |
| 2439 | 65 mm GI Pipe |
| 2440 | 80 mm GI Pipe |
| 2441 | 100 mm GI Pipe |
| 2442 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2443 | 50 mm GI Pipe |
| 2444 | 65 mm GI Pipe |
| 2445 | 80 mm GI Pipe |
| 2446 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2447 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2448 | Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2449 | Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam |
| 2450 | Vadamalaipatti Booster Station |
| 2451 | Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam ) |
| 2452 | Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti |
| 2453 | Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam |
| 2454 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2455 | 9 Amps\440V |
| 2456 | 12 Amps\440V |
| 2457 | 25 Amps\440V |
| 2458 | 45 Amps\440V |
| 2459 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2460 | Upto 5A |
| 2461 | Upto 5A-10A |
| 2462 | Upto 20A-30A |
| 2463 | Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2464 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2465 | 150mm CI sluice valve |
| 2466 | 150 mm CI NRV |
| 2467 | 100 mm CI NRV |
| 2468 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2469 | 50 mm Gate valve |
| 2470 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 2471 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2472 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2473 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2474 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2475 | 0.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai |
| 2476 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 2477 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 398.70 ML (4.43*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2478 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2479 | For DI Pipes of various sizes |
| 2480 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2481 | 350 mm dia DI K9 pipes |
| 2482 | 300 mm dia DI K7 pipes |
| 2483 | 250 mm dia DI K7 pipes |
| 2484 | 200 mm dia DI K7 pipes |
| 2485 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2486 | 350 mm dia DI K9 pipes |
| 2487 | 300 mm dia DI K7 pipes |
| 2488 | 250 mm dia DI K7 pipes |
| 2489 | 200 mm dia DI K7 pipes |
| 2490 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2491 | 350 mm dia DI K9 pipes |
| 2492 | 300 mm dia DI K7 pipes |
| 2493 | 250 mm dia DI K7 pipes |
| 2494 | 200 mm dia DI K7 pipes |
| 2495 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2496 | 350 mm dia DI K9 pipes |
| 2497 | 300 mm dia DI K7 pipes |
| 2498 | 250 mm dia DI K7 pipes |
| 2499 | 200 mm dia DI K7 pipes |
| 2500 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2501 | For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2502 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2503 | For DI Pipes of various classes |
| 2504 | For PVC Pipes of various sizes |
| 2505 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2506 | 50mm PVC 6KSC |
| 2507 | 63mm PVC 4KSC |
| 2508 | 75mm PVC 4KSC |
| 2509 | 90mm PVC 4 KSC |
| 2510 | 110mm PVC 4KSC |
| 2511 | 140mm PVC 4KSC |
| 2512 | 160mm PVC 4KSC |
| 2513 | 200mm PVC 4KSC |
| 2514 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 2515 | 350 mm dia DI K9 pipes |
| 2516 | 300 mm dia DI K7 pipes |
| 2517 | 250 mm dia DI K7 pipes |
| 2518 | 200 mm dia DI K7 pipes |
| 2519 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2520 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2521 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2522 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2523 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2524 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2525 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2526 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2527 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2528 | 350 mm dia DI K9 pipes |
| 2529 | 300 mm dia DI K7 pipes |
| 2530 | 250 mm dia DI K7 pipes |
| 2531 | 200 mm dia DI K7 pipes |
| 2532 | 200mm CID Joint Class 15 |
| 2533 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2534 | 350 mm dia DI K9 pipes |
| 2535 | 300 mm dia DI K7 pipes |
| 2536 | 250 mm dia DI K7 pipes |
| 2537 | 200 mm dia DI K7 pipes |
| 2538 | 50mm PVC 6KSC |
| 2539 | 63mm PVC 4KSC |
| 2540 | 75mm PVC 4KSC |
| 2541 | 90mm PVC 4 KSC |
| 2542 | 110mm PVC 4KSC |
| 2543 | 140mm PVC 4KSC |
| 2544 | 160mm PVC 4KSC |
| 2545 | 200mm PVC 4KSC |
| 2546 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2547 | 50 mm GI Pipe |
| 2548 | 65 mm GI Pipe |
| 2549 | 80 mm GI Pipe |
| 2550 | 100 mm GI Pipe |
| 2551 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2552 | 50 mm GI Pipe |
| 2553 | 65 mm GI Pipe |
| 2554 | 80 mm GI Pipe |
| 2555 | 100 mm GI Pipe |
| 2556 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2557 | 50 mm GI Pipe |
| 2558 | 65 mm GI Pipe |
| 2559 | 80 mm GI Pipe |
| 2560 | 100 mm GI Pipe |
| 2561 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2562 | 50 mm GI Pipe |
| 2563 | 65 mm GI Pipe |
| 2564 | 80 mm GI Pipe |
| 2565 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2566 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2567 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 2568 | Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2569 | Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2570 | Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2571 | Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2572 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by ) |
| 2573 | ALANGULAM ( 5HP X 389 LPM X 25 M ) |
| 2574 | PUDUPATTI ( 2HP X 336 LPM X 16 M ) |
| 2575 | KUTHAPANCHAN (3HP X 199 LPM X 35 M ) |
| 2576 | ANDIPATTI ( 3HP X 360 LPM X 25 M ) |
| 2577 | POOLANKULAM( 2HP X 226 LPM X 28 M ) |
| 2578 | PETHANADARPATTI ( 2HP X 155 LPM X 24 M ) |
| 2579 | NALLUR ( 7.5HP X 627 LPM X 25 M ) |
| 2580 | SIVALARKULAM ( 1HP X 117 LPM X 15 M ) |
| 2581 | MARANTHAI ( 1HP X 51 LPM X 10 M ) |
| 2582 | AYYANARKULAM ( 1HP X 175 LPM X 15 M ) |
| 2583 | SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M ) |
| 2584 | SUBBAIAHPURAM (1HP X 16 LPM X 14 M ) |
| 2585 | NETTUR ( 2HP X 314 LPM X 16 M ) |
| 2586 | KADANGANERI ( 4HP X 614 LPM X 18 M ) |
| 2587 | KADUVETTI ( 1HP X 47 LPM X 13 M ) |
| 2588 | KAVALAKURICHI ( 4HP X 338 LPM X 22 M ) |
| 2589 | V.KAVALAKURICHI (4HP X 248 LPM X 36 M ) |
| 2590 | UTHUMALAI ( 10HP X 790 LPM X 37 M ) |
| 2591 | UTHUMALAI ( 5HP X 579 LPM X 12 M ) |
| 2592 | KANKANANKINARU ( 1HP X 203 LPM X 16 M ) |
| 2593 | MARUKALANKULAM ( 2HP X 266 LPM X 21 M ) |
| 2594 | VANNICONENDHAL ( 3HP X 442 LPM X 18 M ) |
| 2595 | NARIKUDI ( 2HP X 119 LPM X 33 M ) |
| 2596 | V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M ) |
| 2597 | V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M ) |
| 2598 | Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room |
| 2599 | Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 2600 | Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 2601 | Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 2602 | 3 Pole MCCB |
| 2603 | 63 Amps |
| 2604 | 100 Amps |
| 2605 | 150 Amps |
| 2606 | 250 Amps |
| 2607 | 320 Amps |
| 2608 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2609 | 9 Amps\440V |
| 2610 | 12 Amps\440V |
| 2611 | 18 Amps\440V |
| 2612 | 25 Amps\440V |
| 2613 | 140 Amps\440V |
| 2614 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2615 | Upto 5A |
| 2616 | Upto 5A-10A |
| 2617 | Upto 10A-20A |
| 2618 | Upto 50A-75A |
| 2619 | Upto 75A-110A |
| 2620 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 2621 | For 1 HP Starter |
| 2622 | For 3 HP Starter |
| 2623 | For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2624 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2625 | 300 mm CI Sluice valve |
| 2626 | 250 mm CI Sluice valve |
| 2627 | 125 mm CI Sluice valve |
| 2628 | 100 mm CI Sluice valve |
| 2629 | 80 mm CI Sluice valve |
| 2630 | 65 mm CI Sluice valve |
| 2631 | 50 mm CI sluice valve |
| 2632 | 300 mm CI NRV valve |
| 2633 | 250 mm CI NRV valve |
| 2634 | 125 mm CI NRV valve |
| 2635 | 100 mm CI NRV valve |
| 2636 | 80 mm CI NRV valve |
| 2637 | 65 mm CI NRV valve |
| 2638 | 50 mm CI NRV Valve |
| 2639 | 100 mm single Chamber air Release valve |
| 2640 | 80 mm single Chamber air Release valve |
| 2641 | 50 mm single Chamber air Release valve |
| 2642 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2643 | 50 mm Gate valve |
| 2644 | 65 mm Gate valve |
| 2645 | 80 mm Gate valve |
| 2646 | 100 mm Gate valve |
| 2647 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 2648 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2649 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2650 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2651 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2652 | Nanthanthattai 2.15 LL Sump |
| 2653 | Pudupatti 1.40 LL Sump |
| 2654 | Kuthapanchan 0.85 LL Sump |
| 2655 | Alangulam 0.30 LL Sump |
| 2656 | Andipatti 1.50 LL Sump |
| 2657 | Poolankulam 0.95 LL Sump |
| 2658 | Pethanadarpatti 0.65 LL Sump |
| 2659 | Nallur 4.05 LL Sump |
| 2660 | Sivalarkulam 0.50 LL Sump |
| 2661 | Maranthai 0.25 LL Sump |
| 2662 | Ayyanarkulam 0.75 LL Sump |
| 2663 | Subbiahpuram 1.05 LL Sump |
| 2664 | Nettur 1.30 LL Sump |
| 2665 | Kadanganeri 2.55 LL Sump |
| 2666 | Kaduvetti 0.20 LL Sump |
| 2667 | Kavalakurichi 1.40 LL Sump |
| 2668 | Vadakku Kavalakurichi 1.05 LL Sump |
| 2669 | Uthumalai 2.90 LL Sump |
| 2670 | Balabadraramapuram 0.85 LL Sump |
| 2671 | Marukkalankulam 1.10 LL Sump |
| 2672 | Vanniconendal 1.85 LL Sump |
| 2673 | Narikudi 0.50 LL Sump |
| 2674 | Vadakku Panavadaly 2.05 LL Sump For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 2675 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1616.15 ML (4.43*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2676 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2677 | For DI Pipes of various sizes |
| 2678 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2679 | 350 mm dia DI K9 pipes |
| 2680 | 300 mm dia DI K7 pipes |
| 2681 | 250 mm dia DI K7 pipes |
| 2682 | 200 mm dia DI K7 pipes |
| 2683 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2684 | 350 mm dia DI K9 pipes |
| 2685 | 300 mm dia DI K7 pipes |
| 2686 | 250 mm dia DI K7 pipes |
| 2687 | 200 mm dia DI K7 pipes |
| 2688 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2689 | 350 mm dia DI K9 pipes |
| 2690 | 300 mm dia DI K7 pipes |
| 2691 | 250 mm dia DI K7 pipes |
| 2692 | 200 mm dia DI K7 pipes |
| 2693 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2694 | 350 mm dia DI K9 pipes |
| 2695 | 300 mm dia DI K7 pipes |
| 2696 | 250 mm dia DI K7 pipes |
| 2697 | 200 mm dia DI K7 pipes |
| 2698 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2699 | For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2700 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2701 | For DI Pipes of various classes |
| 2702 | For PVC Pipes of various sizes |
| 2703 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2704 | 50mm PVC 6KSC |
| 2705 | 63mm PVC 4KSC |
| 2706 | 75mm PVC 4KSC |
| 2707 | 90mm PVC 4 KSC |
| 2708 | 110mm PVC 4KSC |
| 2709 | 140mm PVC 4KSC |
| 2710 | 160mm PVC 4KSC |
| 2711 | 200mm PVC 4KSC |
| 2712 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 2713 | 350 mm dia DI K9 pipes |
| 2714 | 300 mm dia DI K7 pipes |
| 2715 | 250 mm dia DI K7 pipes |
| 2716 | 200 mm dia DI K7 pipes |
| 2717 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2718 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2719 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2720 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2721 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2722 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2723 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2724 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2725 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2726 | 350 mm dia DI K9 pipes |
| 2727 | 300 mm dia DI K7 pipes |
| 2728 | 250 mm dia DI K7 pipes |
| 2729 | 200 mm dia DI K7 pipes |
| 2730 | 200mm CID Joint Class 15 |
| 2731 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2732 | 350 mm dia DI K9 pipes |
| 2733 | 300 mm dia DI K7 pipes |
| 2734 | 250 mm dia DI K7 pipes |
| 2735 | 200 mm dia DI K7 pipes |
| 2736 | 50mm PVC 6KSC |
| 2737 | 63mm PVC 4KSC |
| 2738 | 75mm PVC 4KSC |
| 2739 | 90mm PVC 4 KSC |
| 2740 | 110mm PVC 4KSC |
| 2741 | 140mm PVC 4KSC |
| 2742 | 160mm PVC 4KSC |
| 2743 | 200mm PVC 4KSC |
| 2744 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2745 | 50 mm GI Pipe |
| 2746 | 65 mm GI Pipe |
| 2747 | 80 mm GI Pipe |
| 2748 | 100 mm GI Pipe |
| 2749 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2750 | 50 mm GI Pipe |
| 2751 | 65 mm GI Pipe |
| 2752 | 80 mm GI Pipe |
| 2753 | 100 mm GI Pipe |
| 2754 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2755 | 50 mm GI Pipe |
| 2756 | 65 mm GI Pipe |
| 2757 | 80 mm GI Pipe |
| 2758 | 100 mm GI Pipe |
| 2759 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2760 | 50 mm GI Pipe |
| 2761 | 65 mm GI Pipe |
| 2762 | 80 mm GI Pipe |
| 2763 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2764 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2765 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 2766 | Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2767 | Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2768 | Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2769 | Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2770 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by ) |
| 2771 | ALANGULAM ( 5HP X 389 LPM X 25 M ) |
| 2772 | PUDUPATTI ( 2HP X 336 LPM X 16 M ) |
| 2773 | KUTHAPANCHAN (3HP X 199 LPM X 35 M ) |
| 2774 | ANDIPATTI ( 3HP X 360 LPM X 25 M ) |
| 2775 | POOLANKULAM( 2HP X 226 LPM X 28 M ) |
| 2776 | PETHANADARPATTI ( 2HP X 155 LPM X 24 M ) |
| 2777 | NALLUR ( 7.5HP X 627 LPM X 25 M ) |
| 2778 | SIVALARKULAM ( 1HP X 117 LPM X 15 M ) |
| 2779 | MARANTHAI ( 1HP X 51 LPM X 10 M ) |
| 2780 | AYYANARKULAM ( 1HP X 175 LPM X 15 M ) |
| 2781 | SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M ) |
| 2782 | SUBBAIAHPURAM (1HP X 16 LPM X 14 M ) |
| 2783 | NETTUR ( 2HP X 314 LPM X 16 M ) |
| 2784 | KADANGANERI ( 4HP X 614 LPM X 18 M ) |
| 2785 | KADUVETTI ( 1HP X 47 LPM X 13 M ) |
| 2786 | KAVALAKURICHI ( 4HP X 338 LPM X 22 M ) |
| 2787 | V.KAVALAKURICHI (4HP X 248 LPM X 36 M ) |
| 2788 | UTHUMALAI ( 10HP X 790 LPM X 37 M ) |
| 2789 | UTHUMALAI ( 5HP X 579 LPM X 12 M ) |
| 2790 | KANKANANKINARU ( 1HP X 203 LPM X 16 M ) |
| 2791 | MARUKALANKULAM ( 2HP X 266 LPM X 21 M ) |
| 2792 | VANNICONENDHAL ( 3HP X 442 LPM X 18 M ) |
| 2793 | NARIKUDI ( 2HP X 119 LPM X 33 M ) |
| 2794 | V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M ) |
| 2795 | V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M ) |
| 2796 | Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room |
| 2797 | Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 2798 | Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 2799 | Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 2800 | 3 Pole MCCB |
| 2801 | 63 Amps |
| 2802 | 100 Amps |
| 2803 | 150 Amps |
| 2804 | 250 Amps |
| 2805 | 320 Amps |
| 2806 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 2807 | 9 Amps\440V |
| 2808 | 12 Amps\440V |
| 2809 | 18 Amps\440V |
| 2810 | 25 Amps\440V |
| 2811 | 140 Amps\440V |
| 2812 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 2813 | Upto 5A |
| 2814 | Upto 5A-10A |
| 2815 | Upto 10A-20A |
| 2816 | Upto 50A-75A |
| 2817 | Upto 75A-110A |
| 2818 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 2819 | For 1 HP Starter |
| 2820 | For 3 HP Starter |
| 2821 | For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 2822 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 2823 | 300 mm CI Sluice valve |
| 2824 | 250 mm CI Sluice valve |
| 2825 | 125 mm CI Sluice valve |
| 2826 | 100 mm CI Sluice valve |
| 2827 | 80 mm CI Sluice valve |
| 2828 | 65 mm CI Sluice valve |
| 2829 | 50 mm CI sluice valve |
| 2830 | 300 mm CI NRV valve |
| 2831 | 250 mm CI NRV valve |
| 2832 | 125 mm CI NRV valve |
| 2833 | 100 mm CI NRV valve |
| 2834 | 80 mm CI NRV valve |
| 2835 | 65 mm CI NRV valve |
| 2836 | 50 mm CI NRV Valve |
| 2837 | 100 mm single Chamber air Release valve |
| 2838 | 80 mm single Chamber air Release valve |
| 2839 | 50 mm single Chamber air Release valve |
| 2840 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 2841 | 50 mm Gate valve |
| 2842 | 65 mm Gate valve |
| 2843 | 80 mm Gate valve |
| 2844 | 100 mm Gate valve |
| 2845 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 2846 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 2847 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 2848 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 2849 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 2850 | Nanthanthattai 2.15 LL Sump |
| 2851 | Pudupatti 1.40 LL Sump |
| 2852 | Kuthapanchan 0.85 LL Sump |
| 2853 | Alangulam 0.30 LL Sump |
| 2854 | Andipatti 1.50 LL Sump |
| 2855 | Poolankulam 0.95 LL Sump |
| 2856 | Pethanadarpatti 0.65 LL Sump |
| 2857 | Nallur 4.05 LL Sump |
| 2858 | Sivalarkulam 0.50 LL Sump |
| 2859 | Maranthai 0.25 LL Sump |
| 2860 | Subbiahpuram 1.05 LL Sump |
| 2861 | Nettur 1.30 LL Sump |
| 2862 | Kadanganeri 2.55 LL Sump |
| 2863 | Kaduvetti 0.20 LL Sump |
| 2864 | Kavalakurichi 1.40 LL Sump |
| 2865 | Vadakku Kavalakurichi 1.05 LL Sump |
| 2866 | Uthumalai 2.90 LL Sump |
| 2867 | Balabadraramapuram 0.85 LL Sump |
| 2868 | Marukkalankulam 1.10 LL Sump |
| 2869 | Vanniconendal 1.85 LL Sump |
| 2870 | Narikudi 0.50 LL Sump |
| 2871 | Vadakku Panavadaly 2.05 LL Sump For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 2872 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1616.15 ML (4.43*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers. |
| 2873 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2874 | For DI Pipes of various sizes |
| 2875 | Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2876 | 350 mm dia DI K9 pipes |
| 2877 | 300 mm dia DI K7 pipes |
| 2878 | 250 mm dia DI K7 pipes |
| 2879 | 200 mm dia DI K7 pipes |
| 2880 | Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers |
| 2881 | 350 mm dia DI K9 pipes |
| 2882 | 300 mm dia DI K7 pipes |
| 2883 | 250 mm dia DI K7 pipes |
| 2884 | 200 mm dia DI K7 pipes |
| 2885 | Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers |
| 2886 | 350 mm dia DI K9 pipes |
| 2887 | 300 mm dia DI K7 pipes |
| 2888 | 250 mm dia DI K7 pipes |
| 2889 | 200 mm dia DI K7 pipes |
| 2890 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers |
| 2891 | 350 mm dia DI K9 pipes |
| 2892 | 300 mm dia DI K7 pipes |
| 2893 | 250 mm dia DI K7 pipes |
| 2894 | 200 mm dia DI K7 pipes |
| 2895 | Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers. |
| 2896 | For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 2897 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 2898 | For DI Pipes of various classes |
| 2899 | For PVC Pipes of various sizes |
| 2900 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 2901 | 50mm PVC 6KSC |
| 2902 | 63mm PVC 4KSC |
| 2903 | 75mm PVC 4KSC |
| 2904 | 90mm PVC 4 KSC |
| 2905 | 110mm PVC 4KSC |
| 2906 | 140mm PVC 4KSC |
| 2907 | 160mm PVC 4KSC |
| 2908 | 200mm PVC 4KSC |
| 2909 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 2910 | 350 mm dia DI K9 pipes |
| 2911 | 300 mm dia DI K7 pipes |
| 2912 | 250 mm dia DI K7 pipes |
| 2913 | 200 mm dia DI K7 pipes |
| 2914 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 2915 | 50 mm PVC Coupler Fabricated 6 KSC |
| 2916 | 63 mm PVC Coupler Fabricated 4 KSC |
| 2917 | 75 mm PVC Coupler Fabricated 4 KSC |
| 2918 | 90 mm PVC Coupler Fabricated 4 KSC |
| 2919 | 110 mm PVC Coupler Fabricated 4 KSC |
| 2920 | 140 mm PVC Coupler Fabricated 4 KSC |
| 2921 | 160 mm PVC Coupler Fabricated 4 KSC |
| 2922 | Supply and Delivery of CID joint class 15 as directed by TWAD Board officers |
| 2923 | 350 mm dia DI K9 pipes |
| 2924 | 300 mm dia DI K7 pipes |
| 2925 | 250 mm dia DI K7 pipes |
| 2926 | 200 mm dia DI K7 pipes |
| 2927 | 200mm CID Joint Class 15 |
| 2928 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 2929 | 350 mm dia DI K9 pipes |
| 2930 | 300 mm dia DI K7 pipes |
| 2931 | 250 mm dia DI K7 pipes |
| 2932 | 200 mm dia DI K7 pipes |
| 2933 | 50mm PVC 6KSC |
| 2934 | 63mm PVC 4KSC |
| 2935 | 75mm PVC 4KSC |
| 2936 | 90mm PVC 4 KSC |
| 2937 | 110mm PVC 4KSC |
| 2938 | 140mm PVC 4KSC |
| 2939 | 160mm PVC 4KSC |
| 2940 | 200mm PVC 4KSC |
| 2941 | Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers. |
| 2942 | 50 mm GI Pipe |
| 2943 | 65 mm GI Pipe |
| 2944 | 80 mm GI Pipe |
| 2945 | 100 mm GI Pipe |
| 2946 | Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers |
| 2947 | 50 mm GI Pipe |
| 2948 | 65 mm GI Pipe |
| 2949 | 80 mm GI Pipe |
| 2950 | 100 mm GI Pipe |
| 2951 | Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers. |
| 2952 | 50 mm GI Pipe |
| 2953 | 65 mm GI Pipe |
| 2954 | 80 mm GI Pipe |
| 2955 | 100 mm GI Pipe |
| 2956 | Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers. |
| 2957 | 50 mm GI Pipe |
| 2958 | 65 mm GI Pipe |
| 2959 | 80 mm GI Pipe |
| 2960 | 100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS |
| 2961 | Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 2962 | Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well |
| 2963 | Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2964 | Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai |
| 2965 | Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2966 | Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur |
| 2967 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by ) |
| 2968 | ALANGULAM ( 5HP X 389 LPM X 25 M ) |
| 2969 | PUDUPATTI ( 2HP X 336 LPM X 16 M ) |
| 2970 | KUTHAPANCHAN (3HP X 199 LPM X 35 M ) |
| 2971 | ANDIPATTI ( 3HP X 360 LPM X 25 M ) |
| 2972 | POOLANKULAM( 2HP X 226 LPM X 28 M ) |
| 2973 | PETHANADARPATTI ( 2HP X 155 LPM X 24 M ) |
| 2974 | NALLUR ( 7.5HP X 627 LPM X 25 M ) |
| 2975 | SIVALARKULAM ( 1HP X 117 LPM X 15 M ) |
| 2976 | MARANTHAI ( 1HP X 51 LPM X 10 M ) |
| 2977 | AYYANARKULAM ( 1HP X 175 LPM X 15 M ) |
| 2978 | SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M ) |
| 2979 | SUBBAIAHPURAM (1HP X 16 LPM X 14 M ) |
| 2980 | NETTUR ( 2HP X 314 LPM X 16 M ) |
| 2981 | KADANGANERI ( 4HP X 614 LPM X 18 M ) |
| 2982 | KADUVETTI ( 1HP X 47 LPM X 13 M ) |
| 2983 | KAVALAKURICHI ( 4HP X 338 LPM X 22 M ) |
| 2984 | V.KAVALAKURICHI (4HP X 248 LPM X 36 M ) |
| 2985 | UTHUMALAI ( 10HP X 790 LPM X 37 M ) |
| 2986 | UTHUMALAI ( 5HP X 579 LPM X 12 M ) |
| 2987 | KANKANANKINARU ( 1HP X 203 LPM X 16 M ) |
| 2988 | MARUKALANKULAM ( 2HP X 266 LPM X 21 M ) |
| 2989 | VANNICONENDHAL ( 3HP X 442 LPM X 18 M ) |
| 2990 | NARIKUDI ( 2HP X 119 LPM X 33 M ) |
| 2991 | V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M ) |
| 2992 | V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M ) |
| 2993 | Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room |
| 2994 | Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 2995 | Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 2996 | Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers. |
| 2997 | 3 Pole MCCB |
| 2998 | 63 Amps |
| 2999 | 100 Amps |
| 3000 | 150 Amps |
| 3001 | 250 Amps |
| 3002 | 320 Amps |
| 3003 | Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers |
| 3004 | 9 Amps\440V |
| 3005 | 12 Amps\440V |
| 3006 | 18 Amps\440V |
| 3007 | 25 Amps\440V |
| 3008 | 140 Amps\440V |
| 3009 | Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers |
| 3010 | Upto 5A |
| 3011 | Upto 5A-10A |
| 3012 | Upto 10A-20A |
| 3013 | Upto 50A-75A |
| 3014 | Upto 75A-110A |
| 3015 | Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers |
| 3016 | For 1 HP Starter |
| 3017 | For 3 HP Starter |
| 3018 | For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 3019 | Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 3020 | 300 mm CI Sluice valve |
| 3021 | 250 mm CI Sluice valve |
| 3022 | 125 mm CI Sluice valve |
| 3023 | 100 mm CI Sluice valve |
| 3024 | 80 mm CI Sluice valve |
| 3025 | 65 mm CI Sluice valve |
| 3026 | 50 mm CI sluice valve |
| 3027 | 300 mm CI NRV valve |
| 3028 | 250 mm CI NRV valve |
| 3029 | 125 mm CI NRV valve |
| 3030 | 100 mm CI NRV valve |
| 3031 | 80 mm CI NRV valve |
| 3032 | 65 mm CI NRV valve |
| 3033 | 50 mm CI NRV Valve |
| 3034 | 100 mm single Chamber air Release valve |
| 3035 | 80 mm single Chamber air Release valve |
| 3036 | 50 mm single Chamber air Release valve |
| 3037 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3038 | 50 mm Gate valve |
| 3039 | 65 mm Gate valve |
| 3040 | 80 mm Gate valve |
| 3041 | 100 mm Gate valve |
| 3042 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 3043 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 3044 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3045 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3046 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3047 | Nanthanthattai 2.15 LL Sump |
| 3048 | Pudupatti 1.40 LL Sump |
| 3049 | Kuthapanchan 0.85 LL Sump |
| 3050 | Alangulam 0.30 LL Sump |
| 3051 | Andipatti 1.50 LL Sump |
| 3052 | Poolankulam 0.95 LL Sump |
| 3053 | Pethanadarpatti 0.65 LL Sump |
| 3054 | Nallur 4.05 LL Sump |
| 3055 | Sivalarkulam 0.50 LL Sump |
| 3056 | Maranthai 0.25 LL Sump |
| 3057 | Subbiahpuram 1.05 LL Sump |
| 3058 | Nettur 1.30 LL Sump |
| 3059 | Kadanganeri 2.55 LL Sump |
| 3060 | Kaduvetti 0.20 LL Sump |
| 3061 | Kavalakurichi 1.40 LL Sump |
| 3062 | Vadakku Kavalakurichi 1.05 LL Sump |
| 3063 | Uthumalai 2.90 LL Sump |
| 3064 | Balabadraramapuram 0.85 LL Sump |
| 3065 | Marukkalankulam 1.10 LL Sump |
| 3066 | Vanniconendal 1.85 LL Sump |
| 3067 | Narikudi 0.50 LL Sump |
| 3068 | Vadakku Panavadaly 2.05 LL Sump |
| 3069 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 3070 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 149.40 ML (1.66*90 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3071 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3072 | For HDPE Pipes of various sizes |
| 3073 | Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 3074 | 50mm HDPE PN6 Pipe |
| 3075 | 63mm HDPE PN6 Pipe |
| 3076 | 75mm HDPE PN6 Pipe |
| 3077 | 90mm HDPE PN6 Pipe |
| 3078 | 110mm HDPE PN6 Pipe |
| 3079 | 160mm HDPE PN6 Pipe |
| 3080 | 200mm HDPE PN6 Pipe |
| 3081 | Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. |
| 3082 | 50mm HDPE PN6 Pipe |
| 3083 | 63mm HDPE PN6 Pipe |
| 3084 | 75mm HDPE PN6 Pipe |
| 3085 | 90mm HDPE PN6 Pipe |
| 3086 | 110mm HDPE PN6 Pipe |
| 3087 | 160mm HDPE PN6 Pipe |
| 3088 | 200mm HDPE PN6 Pipe |
| 3089 | Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 3090 | 50mm 90 degree bend |
| 3091 | 63mm 90 degree bend |
| 3092 | 75mm 90 degree bend |
| 3093 | 90mm 90 degree bend |
| 3094 | 110mm 90 degree bend |
| 3095 | 160mm 90 degree bend |
| 3096 | 200mm 90 degree bend |
| 3097 | 50mm Equal Tee |
| 3098 | 63mm Equal Tee |
| 3099 | 75mm Equal Tee |
| 3100 | 90mm Equal Tee |
| 3101 | 110mm Equal Tee |
| 3102 | 160mm Equal Tee |
| 3103 | 200mm Equal Tee |
| 3104 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3105 | 50mm HDPE PN6 Pipe |
| 3106 | 63mm HDPE PN6 Pipe |
| 3107 | 75mm HDPE PN6 Pipe |
| 3108 | 90mm HDPE PN6 Pipe |
| 3109 | 110mm HDPE PN6 Pipe |
| 3110 | 160mm HDPE PN6 Pipe |
| 3111 | 200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3112 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3113 | Maranthai - 7.50 HP |
| 3114 | Kathapuram - 15 HP |
| 3115 | Thalaisubramaniapuram - 12.50 HP |
| 3116 | Nanthanthattai - 7.50 HP |
| 3117 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3118 | 65 mm Gate valve |
| 3119 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 3120 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3121 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3122 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3123 | 1.05 LL capacity of sump @ Nanthanthattai |
| 3124 | 3.75 LL capacity of sump @ Kathapuram |
| 3125 | 2.4 LL capacity of sump @ Thalai Subramaniyapuram |
| 3126 | 0.45 LL capacity of sump @ Maranthai For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 3127 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 605.90 ML (1.66*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3128 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3129 | For HDPE Pipes of various sizes |
| 3130 | Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 3131 | 50mm HDPE PN6 Pipe |
| 3132 | 63mm HDPE PN6 Pipe |
| 3133 | 75mm HDPE PN6 Pipe |
| 3134 | 90mm HDPE PN6 Pipe |
| 3135 | 110mm HDPE PN6 Pipe |
| 3136 | 160mm HDPE PN6 Pipe |
| 3137 | 200mm HDPE PN6 Pipe |
| 3138 | Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. |
| 3139 | 50mm HDPE PN6 Pipe |
| 3140 | 63mm HDPE PN6 Pipe |
| 3141 | 75mm HDPE PN6 Pipe |
| 3142 | 90mm HDPE PN6 Pipe |
| 3143 | 110mm HDPE PN6 Pipe |
| 3144 | 160mm HDPE PN6 Pipe |
| 3145 | 200mm HDPE PN6 Pipe |
| 3146 | Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 3147 | 50mm 90 degree bend |
| 3148 | 63mm 90 degree bend |
| 3149 | 75mm 90 degree bend |
| 3150 | 90mm 90 degree bend |
| 3151 | 110mm 90 degree bend |
| 3152 | 160mm 90 degree bend |
| 3153 | 200mm 90 degree bend |
| 3154 | 50mm Equal Tee |
| 3155 | 63mm Equal Tee |
| 3156 | 75mm Equal Tee |
| 3157 | 90mm Equal Tee |
| 3158 | 110mm Equal Tee |
| 3159 | 160mm Equal Tee |
| 3160 | 200mm Equal Tee |
| 3161 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3162 | 50mm HDPE PN6 Pipe |
| 3163 | 63mm HDPE PN6 Pipe |
| 3164 | 75mm HDPE PN6 Pipe |
| 3165 | 90mm HDPE PN6 Pipe |
| 3166 | 110mm HDPE PN6 Pipe |
| 3167 | 160mm HDPE PN6 Pipe |
| 3168 | 200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3169 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3170 | Maranthai - 7.50 HP |
| 3171 | Kathapuram - 15 HP |
| 3172 | Thalaisubramaniapuram - 12.50 HP |
| 3173 | Nanthanthattai - 7.50 HP |
| 3174 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3175 | 50 mm Gate valve |
| 3176 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 3177 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3178 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3179 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3180 | 1.05 LL capacity of sump @ Nanthanthattai |
| 3181 | 3.75 LL capacity of sump @ Kathapuram |
| 3182 | 2.4 LL capacity of sump @ Thalai Subramaniyapuram |
| 3183 | 0.45 LL capacity of sump @ Maranthai For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 3184 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 605.90 ML (1.66*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3185 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3186 | For HDPE Pipes of various sizes |
| 3187 | Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers. |
| 3188 | 50mm HDPE PN6 Pipe |
| 3189 | 63mm HDPE PN6 Pipe |
| 3190 | 75mm HDPE PN6 Pipe |
| 3191 | 90mm HDPE PN6 Pipe |
| 3192 | 110mm HDPE PN6 Pipe |
| 3193 | 160mm HDPE PN6 Pipe |
| 3194 | 200mm HDPE PN6 Pipe |
| 3195 | Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. |
| 3196 | 50mm HDPE PN6 Pipe |
| 3197 | 63mm HDPE PN6 Pipe |
| 3198 | 75mm HDPE PN6 Pipe |
| 3199 | 90mm HDPE PN6 Pipe |
| 3200 | 110mm HDPE PN6 Pipe |
| 3201 | 160mm HDPE PN6 Pipe |
| 3202 | 200mm HDPE PN6 Pipe |
| 3203 | Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers |
| 3204 | 50mm 90 degree bend |
| 3205 | 63mm 90 degree bend |
| 3206 | 75mm 90 degree bend |
| 3207 | 90mm 90 degree bend |
| 3208 | 110mm 90 degree bend |
| 3209 | 160mm 90 degree bend |
| 3210 | 200mm 90 degree bend |
| 3211 | 50mm Equal Tee |
| 3212 | 63mm Equal Tee |
| 3213 | 75mm Equal Tee |
| 3214 | 90mm Equal Tee |
| 3215 | 110mm Equal Tee |
| 3216 | 160mm Equal Tee |
| 3217 | 200mm Equal Tee |
| 3218 | Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3219 | 50mm HDPE PN6 Pipe |
| 3220 | 63mm HDPE PN6 Pipe |
| 3221 | 75mm HDPE PN6 Pipe |
| 3222 | 90mm HDPE PN6 Pipe |
| 3223 | 110mm HDPE PN6 Pipe |
| 3224 | 160mm HDPE PN6 Pipe |
| 3225 | 200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3226 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3227 | Maranthai - 7.50 HP |
| 3228 | Kathapuram - 15 HP |
| 3229 | Thalaisubramaniapuram - 12.50 HP |
| 3230 | Nanthanthattai - 7.50 HP |
| 3231 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3232 | 65 mm Gate valve |
| 3233 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 3234 | Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS |
| 3235 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3236 | Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3237 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3238 | 1.05 LL capacity of sump @ Nanthanthattai |
| 3239 | 3.75 LL capacity of sump @ Kathapuram |
| 3240 | 2.4 LL capacity of sump @ Thalai Subramaniyapuram |
| 3241 | 0.45 LL capacity of sump @ Maranthai |
| 3242 | 2.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD |
| 3243 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 721.44 ML (8.016*90 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3244 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3245 | For DI Pipes of various sizes |
| 3246 | For PVC Pipes of various sizes |
| 3247 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 3248 | 450 mm dia DI K7 pipes- |
| 3249 | 400 mm dia DI K7 pipes- |
| 3250 | 350 mm dia DI K7 pipes- |
| 3251 | 300 mm dia DI K7 Pipe |
| 3252 | 250 mm dia DI K7 Pipe |
| 3253 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 3254 | 50mm PVC 6KSC |
| 3255 | 63mm PVC 4KSC |
| 3256 | 75mm PVC 4KSC |
| 3257 | 90mm PVC 4 KSC |
| 3258 | 110mm PVC 4KSC |
| 3259 | 140mm PVC 4KSC |
| 3260 | 160mm PVC 4KSC |
| 3261 | 200mm PVC 4KSC |
| 3262 | 63mm PVC 6KSC |
| 3263 | 110mm PVC 6KSC |
| 3264 | 140mm PVC 6KSC |
| 3265 | 200 mm PVC 6KSC |
| 3266 | 200 mm PVC 10KSC |
| 3267 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 3268 | 63mm 4KSC PVC Coupler |
| 3269 | 75mm 4KSC PVC Coupler |
| 3270 | 90mm 4KSC PVC Coupler |
| 3271 | 110mm 4KSC PVC Coupler |
| 3272 | 140mm 4KSC PVC Coupler |
| 3273 | 160mm 4KSC PVC Coupler |
| 3274 | 200mm 4KSC PVC Coupler |
| 3275 | 50mm 6KSC PVC Coupler |
| 3276 | 63mm 6KSC PVC Coupler |
| 3277 | 75mm 6KSC PVC Coupler |
| 3278 | 90mm 6KSC PVC Coupler |
| 3279 | 110mm 6KSC PVC Coupler |
| 3280 | 160mm 6KSC PVC Coupler |
| 3281 | 140mm 6KSC PVC Coupler |
| 3282 | 200mm 6KSC PVC Coupler |
| 3283 | 50mm 4KSC PVC bend |
| 3284 | 63mm 4KSC PVC bend |
| 3285 | 75mm 4KSC PVC bend |
| 3286 | 90mm 4KSC PVC bend |
| 3287 | 110mm 4KSC PVC bend |
| 3288 | 140mm 4KSC PVC bend |
| 3289 | 160mm 4KSC PVC bend |
| 3290 | 200mm 4KSC PVC bend |
| 3291 | 50mm 6KSC PVC bend |
| 3292 | 63mm 6KSC PVC bend |
| 3293 | 75mm 6KSC PVC bend |
| 3294 | 90mm 6KSC PVC bend |
| 3295 | 110mm 6KSC PVC bend |
| 3296 | 160mm 6KSC PVC bend |
| 3297 | 140mm 6KSC PVC bend |
| 3298 | 200mm 6KSC PVC bend |
| 3299 | 63mm 4KSC PVC Equal Tee |
| 3300 | 75mm 4KSC PVC Equal Tee |
| 3301 | 90mm 4KSC PVC Equal Tee |
| 3302 | 110mm 4KSC PVC Equal Tee |
| 3303 | 140mm 4KSC PVC Equal Tee |
| 3304 | 160mm 4KSC PVC Equal Tee |
| 3305 | 200mm 4KSC PVC Equal Tee |
| 3306 | 50mm 6KSC PVC Equal Tee |
| 3307 | 63mm 6KSC PVC Equal Tee |
| 3308 | 75mm 6KSC PVC Equal Tee |
| 3309 | 90mm 6KSC PVC Equal Tee |
| 3310 | 110mm 6KSC PVC Equal Tee |
| 3311 | 140mm 6KSC PVC Equal Tee |
| 3312 | 160mm 6KSC PVC Equal Tee |
| 3313 | 200mm 6KSC PVC Equal Tee |
| 3314 | 50mm PVC MTA |
| 3315 | 63mm PVC MTA |
| 3316 | 75mm PVC MTA |
| 3317 | 90mm PVC MTA |
| 3318 | 110mm PVC MTA |
| 3319 | 140mm PVC MTA |
| 3320 | 160mm PVC MTA |
| 3321 | 200mm PVC MTA |
| 3322 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 3323 | For Diesel Pump set for 5 HP |
| 3324 | For Diesel Pump set for 7.5 HP |
| 3325 | Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers |
| 3326 | 450 DI K7 Pipe |
| 3327 | 400 DI K7 Pipe |
| 3328 | 350 DI K7 Pipe |
| 3329 | 300 DI K7 Pipe |
| 3330 | 250 DI K7 Pipe |
| 3331 | Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3332 | 450 mm dia DI K7 pipes- |
| 3333 | 400 mm dia DI K7 pipes- |
| 3334 | 350 mm dia DI K7 pipes- |
| 3335 | 300 mm dia DI K7 Pipe |
| 3336 | 250 mm dia DI K7 Pipe |
| 3337 | 50mm PVC 4KSC |
| 3338 | 63mm PVC 4KSC |
| 3339 | 75mm PVC 4KSC |
| 3340 | 90mm PVC 4 KSC |
| 3341 | 110mm PVC 4KSC |
| 3342 | 140mm PVC 4KSC |
| 3343 | 160mm PVC 4KSC |
| 3344 | 200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3345 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3346 | Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP |
| 3347 | Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP |
| 3348 | Keelambur sump - 3 HP |
| 3349 | Keelambur sump -5 HP |
| 3350 | Meelambur sump - 4 HP |
| 3351 | Sivasailam sump - 3 HP |
| 3352 | Dharamapuram madam sump - 1 HP |
| 3353 | Papankulam sump - 4HP |
| 3354 | Papankulam sump - 1HP |
| 3355 | Papankulam sump - 7.5 HP |
| 3356 | Papankulam sump - 3 HP |
| 3357 | Papankulam sump - 5 HP |
| 3358 | A.P.nadanoor sump - 2HP |
| 3359 | A.P.nadanoor sump - 1HP |
| 3360 | Thuppakudi sump - 1HP |
| 3361 | Rengasamudram sump - 1HP |
| 3362 | Adaichani sump - 1HP |
| 3363 | Pallakal sump - 4HP |
| 3364 | Idaikal sump - 5HP |
| 3365 | Kabalibarai sump - 1HP |
| 3366 | Pappakudi sump - 2HP |
| 3367 | Pottalpudur sump - 1HP |
| 3368 | Pottalpudur sump - 1HP |
| 3369 | Ravanasamduram sump - 2HP |
| 3370 | Veerasamduram sump - 1HP |
| 3371 | Manthiyoor sump - 2HP |
| 3372 | Mudhaliyarpatti sump - 1HP |
| 3373 | Keelakadaiyam sump - 1HP |
| 3374 | Keelakadaiyam sump - 20HP |
| 3375 | Keelakadaiyam sump - 3HP |
| 3376 | Sarvaikaranpatti sump - 1HP |
| 3377 | Sarvaikaranpatti sump - 1HP |
| 3378 | Kadayam perumbathu sump - 1HP |
| 3379 | Kadayam perumbathu sump - 1HP |
| 3380 | Avudayanoor sump - 1HP |
| 3381 | Avudayanoor sump - 1HP |
| 3382 | Sivanadanoor sump - 1HP |
| 3383 | Sivanadanoor sump - 1HP |
| 3384 | Kallorani sump - 2HP |
| 3385 | Kulasekarapatti sump - 3HP |
| 3386 | Kulasekarapatti sump - 1HP |
| 3387 | Kulasekarapatti sump - 1HP |
| 3388 | SSK Nagar - 1HP |
| 3389 | Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE |
| 3390 | Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 3391 | 3 core 10 Sq. mm aluminium cable |
| 3392 | 3 core 25 Sq. mm aluminium cable |
| 3393 | 3 core 50 Sq. mm aluminium cable |
| 3394 | 3 core 95 Sq. mm aluminium cable |
| 3395 | 3 core 185 Sq. mm aluminium cable |
| 3396 | 3.5 core 50 Sq. mm aluminium cable |
| 3397 | 3.5 core 95 Sq. mm aluminium cable |
| 3398 | 3.5 core 185 Sq. mm aluminium cable |
| 3399 | Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3400 | 3 core 10 Sq. mm aluminium cable |
| 3401 | 3 core 25 Sq. mm aluminium cable |
| 3402 | 3 core 50 Sq. mm aluminium cable |
| 3403 | 3 core 95 Sq. mm aluminium cable |
| 3404 | 3 core 185 Sq. mm aluminium cable |
| 3405 | 3.5 core 50 Sq. mm aluminium cable |
| 3406 | 3.5 core 95 Sq. mm aluminium cable |
| 3407 | 3.5 core 185 Sq. mm aluminium cable |
| 3408 | Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3409 | 3 core 10 Sq. mm aluminium cable |
| 3410 | 3 core 25 Sq. mm aluminium cable |
| 3411 | 3 core 50 Sq. mm aluminium cable |
| 3412 | 3 core 95 Sq. mm aluminium cable |
| 3413 | 3 core 185 Sq. mm aluminium cable |
| 3414 | 3.5 core 50 Sq. mm aluminium cable |
| 3415 | 3.5 core 95 Sq. mm aluminium cable |
| 3416 | 3.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE |
| 3417 | Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board. |
| 3418 | 3 core 4 Sq. mm copper flat cable |
| 3419 | 3 core 6 Sq. mm copper flat cable |
| 3420 | 3 core 10 Sq. mm copper flat cable |
| 3421 | Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3422 | 3 core 4 Sq. mm copper flat cable |
| 3423 | 3 core 6 Sq. mm copper flat cable |
| 3424 | 3 core 10 Sq. mm copper flat cable |
| 3425 | Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3426 | 3 core 4 Sq. mm copper flat cable |
| 3427 | 3 core 6 Sq. mm copper flat cable |
| 3428 | 3 core 10 Sq. mm copper flat cable |
| 3429 | Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 3430 | 250 Amps |
| 3431 | 400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 3432 | Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 3433 | 400 mm CI Sluice valve |
| 3434 | 350 mm CI Sluice valve |
| 3435 | 250 mm CI Sluice valve |
| 3436 | 200 mm CI Sluice valve |
| 3437 | 150 mm CI Sluice valve |
| 3438 | 125 mm CI Sluice valve |
| 3439 | 100 mm CI Sluice valve |
| 3440 | 80 mm Sluice valve |
| 3441 | 65 mm CI Sluice valve |
| 3442 | 50 mm sluice valve |
| 3443 | 150 mm CI NRV valve |
| 3444 | 125 mm CI NRV valve |
| 3445 | 100 mm CI NRV valve |
| 3446 | 80 mm CI NRV valve |
| 3447 | 65 mm CI NRV valve |
| 3448 | 50 mm CI NRV Valve |
| 3449 | 50 mm double airvalve |
| 3450 | 40 mm single airvalve |
| 3451 | 100 mm DI single chamber Air release Valve |
| 3452 | 80mm single chamber Air release Valve |
| 3453 | 50mm single chamber Air release Valve |
| 3454 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 3455 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3456 | 50 mm Gate valve |
| 3457 | 65 mm Gate valve |
| 3458 | 80 mm Gate valve |
| 3459 | 100 mm Gate valve |
| 3460 | 125 mm Gate valve |
| 3461 | Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3462 | 50 mm NRV |
| 3463 | 65 mm NRV |
| 3464 | 80 mm NRV COST OF CHEMICALS |
| 3465 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3466 | Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3467 | Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3468 | Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3469 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3470 | Clear water sump - 400000 Litres |
| 3471 | Recirculation sump - 100000 Litre |
| 3472 | Keela Ambur - 215000 Litres |
| 3473 | Mela Ambur - - 135000 Litres |
| 3474 | Siva Sailam - - 65000 Litres |
| 3475 | Dharmapuramadam - 110000 Litres |
| 3476 | Pappankulam @ Common sump - -650000 Litres |
| 3477 | A.P.Nadanoor -- 160000 Litres |
| 3478 | Thuppakudi - - 55000 Litres |
| 3479 | Rangasamudram - 25000 Litres |
| 3480 | Adaichani - 75000 Litres |
| 3481 | Pallakal - 165000 Litres |
| 3482 | Idaikal - 155000 Litres |
| 3483 | Kabali parai - 40000 Litres |
| 3484 | Pappakudi - 95000 Litres |
| 3485 | Pottalpudur - 35000 Litres |
| 3486 | Ravanasamudram - 105000 Litres |
| 3487 | Veerasamudram - 45000 Litres |
| 3488 | Manthiyoor - 100000 Litres |
| 3489 | Mudaliarpatti - - 45000 Litres |
| 3490 | Keela Kadayam - 140000 Litres |
| 3491 | Servaikaranpatti - 50000 Litres |
| 3492 | Kadayamperum pathu - 60000 Litres |
| 3493 | S.S.K. Nagar - 15000 Litres |
| 3494 | Avudayanoor (IPP) - 60000 Litres |
| 3495 | Gunaramanallur(IPP) - 85000 Litres |
| 3496 | Kallorani(IPP) - 90000 Litres |
| 3497 | Kulasekarapatti(IPP) - 110000 Litres |
| 3498 | KEELAPAVOOR T.P - 65000 Litres For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD |
| 3499 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 2925.84 ML (8.16*366 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3500 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3501 | For DI Pipes of various sizes |
| 3502 | For PVC Pipes of various sizes |
| 3503 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 3504 | 450 mm dia DI K7 pipes- |
| 3505 | 400 mm dia DI K7 pipes- |
| 3506 | 350 mm dia DI K7 pipes- |
| 3507 | 300 mm dia DI K7 Pipe |
| 3508 | 250 mm dia DI K7 Pipe |
| 3509 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 3510 | 50mm PVC 6KSC |
| 3511 | 63mm PVC 4KSC |
| 3512 | 75mm PVC 4KSC |
| 3513 | 90mm PVC 4 KSC |
| 3514 | 110mm PVC 4KSC |
| 3515 | 140mm PVC 4KSC |
| 3516 | 160mm PVC 4KSC |
| 3517 | 200mm PVC 4KSC |
| 3518 | 63mm PVC 6KSC |
| 3519 | 110mm PVC 6KSC |
| 3520 | 140mm PVC 6KSC |
| 3521 | 200 mm PVC 6KSC |
| 3522 | 200 mm PVC 10KSC |
| 3523 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 3524 | 63mm 4KSC PVC Coupler |
| 3525 | 75mm 4KSC PVC Coupler |
| 3526 | 90mm 4KSC PVC Coupler |
| 3527 | 110mm 4KSC PVC Coupler |
| 3528 | 140mm 4KSC PVC Coupler |
| 3529 | 160mm 4KSC PVC Coupler |
| 3530 | 200mm 4KSC PVC Coupler |
| 3531 | 50mm 6KSC PVC Coupler |
| 3532 | 63mm 6KSC PVC Coupler |
| 3533 | 75mm 6KSC PVC Coupler |
| 3534 | 90mm 6KSC PVC Coupler |
| 3535 | 110mm 6KSC PVC Coupler |
| 3536 | 160mm 6KSC PVC Coupler |
| 3537 | 140mm 6KSC PVC Coupler |
| 3538 | 200mm 6KSC PVC Coupler |
| 3539 | 50mm 4KSC PVC bend |
| 3540 | 63mm 4KSC PVC bend |
| 3541 | 75mm 4KSC PVC bend |
| 3542 | 90mm 4KSC PVC bend |
| 3543 | 110mm 4KSC PVC bend |
| 3544 | 140mm 4KSC PVC bend |
| 3545 | 160mm 4KSC PVC bend |
| 3546 | 200mm 4KSC PVC bend |
| 3547 | 50mm 6KSC PVC bend |
| 3548 | 63mm 6KSC PVC bend |
| 3549 | 75mm 6KSC PVC bend |
| 3550 | 90mm 6KSC PVC bend |
| 3551 | 110mm 6KSC PVC bend |
| 3552 | 160mm 6KSC PVC bend |
| 3553 | 140mm 6KSC PVC bend |
| 3554 | 200mm 6KSC PVC bend |
| 3555 | 63mm 4KSC PVC Equal Tee |
| 3556 | 75mm 4KSC PVC Equal Tee |
| 3557 | 90mm 4KSC PVC Equal Tee |
| 3558 | 110mm 4KSC PVC Equal Tee |
| 3559 | 140mm 4KSC PVC Equal Tee |
| 3560 | 160mm 4KSC PVC Equal Tee |
| 3561 | 200mm 4KSC PVC Equal Tee |
| 3562 | 50mm 6KSC PVC Equal Tee |
| 3563 | 63mm 6KSC PVC Equal Tee |
| 3564 | 75mm 6KSC PVC Equal Tee |
| 3565 | 90mm 6KSC PVC Equal Tee |
| 3566 | 110mm 6KSC PVC Equal Tee |
| 3567 | 140mm 6KSC PVC Equal Tee |
| 3568 | 160mm 6KSC PVC Equal Tee |
| 3569 | 200mm 6KSC PVC Equal Tee |
| 3570 | 50mm PVC MTA |
| 3571 | 63mm PVC MTA |
| 3572 | 75mm PVC MTA |
| 3573 | 90mm PVC MTA |
| 3574 | 110mm PVC MTA |
| 3575 | 140mm PVC MTA |
| 3576 | 160mm PVC MTA |
| 3577 | 200mm PVC MTA |
| 3578 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 3579 | For Diesel Pump set for 5 HP |
| 3580 | For Diesel Pump set for 7.5 HP |
| 3581 | Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers |
| 3582 | 450 DI K7 Pipe |
| 3583 | 400 DI K7 Pipe |
| 3584 | 350 DI K7 Pipe |
| 3585 | 300 DI K7 Pipe |
| 3586 | 250 DI K7 Pipe |
| 3587 | Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3588 | 450 mm dia DI K7 pipes- |
| 3589 | 400 mm dia DI K7 pipes- |
| 3590 | 350 mm dia DI K7 pipes- |
| 3591 | 300 mm dia DI K7 Pipe |
| 3592 | 250 mm dia DI K7 Pipe |
| 3593 | 50mm PVC 4KSC |
| 3594 | 63mm PVC 4KSC |
| 3595 | 75mm PVC 4KSC |
| 3596 | 90mm PVC 4 KSC |
| 3597 | 110mm PVC 4KSC |
| 3598 | 140mm PVC 4KSC |
| 3599 | 160mm PVC 4KSC |
| 3600 | 200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3601 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3602 | Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP |
| 3603 | Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP |
| 3604 | Keelambur sump - 3 HP |
| 3605 | Keelambur sump -5 HP |
| 3606 | Meelambur sump - 4 HP |
| 3607 | Sivasailam sump - 3 HP |
| 3608 | Dharamapuram madam sump - 1 HP |
| 3609 | Papankulam sump - 4HP |
| 3610 | Papankulam sump - 1HP |
| 3611 | Papankulam sump - 7.5 HP |
| 3612 | Papankulam sump - 3 HP |
| 3613 | Papankulam sump - 5 HP |
| 3614 | A.P.nadanoor sump - 2HP |
| 3615 | A.P.nadanoor sump - 1HP |
| 3616 | Thuppakudi sump - 1HP |
| 3617 | Rengasamudram sump - 1HP |
| 3618 | Adaichani sump - 1HP |
| 3619 | Pallakal sump - 4HP |
| 3620 | Idaikal sump - 5HP |
| 3621 | Kabalibarai sump - 1HP |
| 3622 | Pappakudi sump - 2HP |
| 3623 | Pottalpudur sump - 1HP |
| 3624 | Pottalpudur sump - 1HP |
| 3625 | Ravanasamduram sump - 2HP |
| 3626 | Veerasamduram sump - 1HP |
| 3627 | Manthiyoor sump - 2HP |
| 3628 | Mudhaliyarpatti sump - 1HP |
| 3629 | Keelakadaiyam sump - 1HP |
| 3630 | Keelakadaiyam sump - 20HP |
| 3631 | Keelakadaiyam sump - 3HP |
| 3632 | Sarvaikaranpatti sump - 1HP |
| 3633 | Sarvaikaranpatti sump - 1HP |
| 3634 | Kadayam perumbathu sump - 1HP |
| 3635 | Kadayam perumbathu sump - 1HP |
| 3636 | Avudayanoor sump - 1HP |
| 3637 | Avudayanoor sump - 1HP |
| 3638 | Sivanadanoor sump - 1HP |
| 3639 | Sivanadanoor sump - 1HP |
| 3640 | Kallorani sump - 2HP |
| 3641 | Kulasekarapatti sump - 3HP |
| 3642 | Kulasekarapatti sump - 1HP |
| 3643 | Kulasekarapatti sump - 1HP |
| 3644 | SSK Nagar - 1HP |
| 3645 | Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE |
| 3646 | Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 3647 | 3 core 10 Sq. mm aluminium cable |
| 3648 | 3 core 25 Sq. mm aluminium cable |
| 3649 | 3 core 50 Sq. mm aluminium cable |
| 3650 | 3 core 95 Sq. mm aluminium cable |
| 3651 | 3 core 185 Sq. mm aluminium cable |
| 3652 | 3.5 core 50 Sq. mm aluminium cable |
| 3653 | 3.5 core 95 Sq. mm aluminium cable |
| 3654 | 3.5 core 185 Sq. mm aluminium cable |
| 3655 | Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3656 | 3 core 10 Sq. mm aluminium cable |
| 3657 | 3 core 25 Sq. mm aluminium cable |
| 3658 | 3 core 50 Sq. mm aluminium cable |
| 3659 | 3 core 95 Sq. mm aluminium cable |
| 3660 | 3 core 185 Sq. mm aluminium cable |
| 3661 | 3.5 core 50 Sq. mm aluminium cable |
| 3662 | 3.5 core 95 Sq. mm aluminium cable |
| 3663 | 3.5 core 185 Sq. mm aluminium cable |
| 3664 | Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3665 | 3 core 10 Sq. mm aluminium cable |
| 3666 | 3 core 25 Sq. mm aluminium cable |
| 3667 | 3 core 50 Sq. mm aluminium cable |
| 3668 | 3 core 95 Sq. mm aluminium cable |
| 3669 | 3 core 185 Sq. mm aluminium cable |
| 3670 | 3.5 core 50 Sq. mm aluminium cable |
| 3671 | 3.5 core 95 Sq. mm aluminium cable |
| 3672 | 3.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE |
| 3673 | Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board. |
| 3674 | 3 core 4 Sq. mm copper flat cable |
| 3675 | 3 core 6 Sq. mm copper flat cable |
| 3676 | 3 core 10 Sq. mm copper flat cable |
| 3677 | Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3678 | 3 core 4 Sq. mm copper flat cable |
| 3679 | 3 core 6 Sq. mm copper flat cable |
| 3680 | 3 core 10 Sq. mm copper flat cable |
| 3681 | Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3682 | 3 core 4 Sq. mm copper flat cable |
| 3683 | 3 core 6 Sq. mm copper flat cable |
| 3684 | 3 core 10 Sq. mm copper flat cable |
| 3685 | Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 3686 | 250 Amps |
| 3687 | 400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 3688 | Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 3689 | 400 mm CI Sluice valve |
| 3690 | 350 mm CI Sluice valve |
| 3691 | 250 mm CI Sluice valve |
| 3692 | 200 mm CI Sluice valve |
| 3693 | 150 mm CI Sluice valve |
| 3694 | 125 mm CI Sluice valve |
| 3695 | 100 mm CI Sluice valve |
| 3696 | 80 mm Sluice valve |
| 3697 | 65 mm CI Sluice valve |
| 3698 | 50 mm sluice valve |
| 3699 | 150 mm CI NRV valve |
| 3700 | 125 mm CI NRV valve |
| 3701 | 100 mm CI NRV valve |
| 3702 | 80 mm CI NRV valve |
| 3703 | 65 mm CI NRV valve |
| 3704 | 50 mm CI NRV Valve |
| 3705 | 50 mm double airvalve |
| 3706 | 40 mm single airvalve |
| 3707 | 100 mm DI single chamber Air release Valve |
| 3708 | 80mm single chamber Air release Valve |
| 3709 | 50mm single chamber Air release Valve |
| 3710 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 3711 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3712 | 50 mm Gate valve |
| 3713 | 65 mm Gate valve |
| 3714 | 80 mm Gate valve |
| 3715 | 100 mm Gate valve |
| 3716 | 125 mm Gate valve |
| 3717 | Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3718 | 50 mm NRV |
| 3719 | 65 mm NRV |
| 3720 | 80 mm NRV COST OF CHEMICALS |
| 3721 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3722 | Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3723 | Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3724 | Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3725 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3726 | Clear water sump - 400000 Litres |
| 3727 | Recirculation sump - 100000 Litre |
| 3728 | Keela Ambur - 215000 Litres |
| 3729 | Mela Ambur - - 135000 Litres |
| 3730 | Siva Sailam - - 65000 Litres |
| 3731 | Dharmapuramadam - 110000 Litres |
| 3732 | Pappankulam @ Common sump - -650000 Litres |
| 3733 | A.P.Nadanoor -- 160000 Litres |
| 3734 | Thuppakudi - - 55000 Litres |
| 3735 | Rangasamudram - 25000 Litres |
| 3736 | Adaichani - 75000 Litres |
| 3737 | Pallakal - 165000 Litres |
| 3738 | Idaikal - 155000 Litres |
| 3739 | Kabali parai - 40000 Litres |
| 3740 | Pappakudi - 95000 Litres |
| 3741 | Pottalpudur - 35000 Litres |
| 3742 | Ravanasamudram - 105000 Litres |
| 3743 | Veerasamudram - 45000 Litres |
| 3744 | Manthiyoor - 100000 Litres |
| 3745 | Mudaliarpatti - - 45000 Litres |
| 3746 | Keela Kadayam - 140000 Litres |
| 3747 | Servaikaranpatti - 50000 Litres |
| 3748 | Kadayamperum pathu - 60000 Litres |
| 3749 | S.S.K. Nagar - 15000 Litres |
| 3750 | Avudayanoor (IPP) - 60000 Litres |
| 3751 | Gunaramanallur(IPP) - 85000 Litres |
| 3752 | Kallorani(IPP) - 90000 Litres |
| 3753 | Kulasekarapatti(IPP) - 110000 Litres |
| 3754 | KEELAPAVOOR T.P - 65000 Litres For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD |
| 3755 | Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 2925.84 ML (8.16*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers. |
| 3756 | Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers. |
| 3757 | For DI Pipes of various sizes |
| 3758 | For PVC Pipes of various sizes |
| 3759 | Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers. |
| 3760 | 450 mm dia DI K7 pipes- |
| 3761 | 400 mm dia DI K7 pipes- |
| 3762 | 350 mm dia DI K7 pipes- |
| 3763 | 300 mm dia DI K7 Pipe |
| 3764 | 250 mm dia DI K7 Pipe |
| 3765 | Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers. |
| 3766 | 50mm PVC 6KSC |
| 3767 | 63mm PVC 4KSC |
| 3768 | 75mm PVC 4KSC |
| 3769 | 90mm PVC 4 KSC |
| 3770 | 110mm PVC 4KSC |
| 3771 | 140mm PVC 4KSC |
| 3772 | 160mm PVC 4KSC |
| 3773 | 200mm PVC 4KSC |
| 3774 | 63mm PVC 6KSC |
| 3775 | 110mm PVC 6KSC |
| 3776 | 140mm PVC 6KSC |
| 3777 | 200 mm PVC 6KSC |
| 3778 | 200 mm PVC 10KSC |
| 3779 | Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers. |
| 3780 | 63mm 4KSC PVC Coupler |
| 3781 | 75mm 4KSC PVC Coupler |
| 3782 | 90mm 4KSC PVC Coupler |
| 3783 | 110mm 4KSC PVC Coupler |
| 3784 | 140mm 4KSC PVC Coupler |
| 3785 | 160mm 4KSC PVC Coupler |
| 3786 | 200mm 4KSC PVC Coupler |
| 3787 | 50mm 6KSC PVC Coupler |
| 3788 | 63mm 6KSC PVC Coupler |
| 3789 | 75mm 6KSC PVC Coupler |
| 3790 | 90mm 6KSC PVC Coupler |
| 3791 | 110mm 6KSC PVC Coupler |
| 3792 | 160mm 6KSC PVC Coupler |
| 3793 | 140mm 6KSC PVC Coupler |
| 3794 | 200mm 6KSC PVC Coupler |
| 3795 | 50mm 4KSC PVC bend |
| 3796 | 63mm 4KSC PVC bend |
| 3797 | 75mm 4KSC PVC bend |
| 3798 | 90mm 4KSC PVC bend |
| 3799 | 110mm 4KSC PVC bend |
| 3800 | 140mm 4KSC PVC bend |
| 3801 | 160mm 4KSC PVC bend |
| 3802 | 200mm 4KSC PVC bend |
| 3803 | 50mm 6KSC PVC bend |
| 3804 | 63mm 6KSC PVC bend |
| 3805 | 75mm 6KSC PVC bend |
| 3806 | 90mm 6KSC PVC bend |
| 3807 | 110mm 6KSC PVC bend |
| 3808 | 160mm 6KSC PVC bend |
| 3809 | 140mm 6KSC PVC bend |
| 3810 | 200mm 6KSC PVC bend |
| 3811 | 63mm 4KSC PVC Equal Tee |
| 3812 | 75mm 4KSC PVC Equal Tee |
| 3813 | 90mm 4KSC PVC Equal Tee |
| 3814 | 110mm 4KSC PVC Equal Tee |
| 3815 | 140mm 4KSC PVC Equal Tee |
| 3816 | 160mm 4KSC PVC Equal Tee |
| 3817 | 200mm 4KSC PVC Equal Tee |
| 3818 | 50mm 6KSC PVC Equal Tee |
| 3819 | 63mm 6KSC PVC Equal Tee |
| 3820 | 75mm 6KSC PVC Equal Tee |
| 3821 | 90mm 6KSC PVC Equal Tee |
| 3822 | 110mm 6KSC PVC Equal Tee |
| 3823 | 140mm 6KSC PVC Equal Tee |
| 3824 | 160mm 6KSC PVC Equal Tee |
| 3825 | 200mm 6KSC PVC Equal Tee |
| 3826 | 50mm PVC MTA |
| 3827 | 63mm PVC MTA |
| 3828 | 75mm PVC MTA |
| 3829 | 90mm PVC MTA |
| 3830 | 110mm PVC MTA |
| 3831 | 140mm PVC MTA |
| 3832 | 160mm PVC MTA |
| 3833 | 200mm PVC MTA |
| 3834 | Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers |
| 3835 | For Diesel Pump set for 5 HP |
| 3836 | For Diesel Pump set for 7.5 HP |
| 3837 | Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers |
| 3838 | 450 DI K7 Pipe |
| 3839 | 400 DI K7 Pipe |
| 3840 | 350 DI K7 Pipe |
| 3841 | 300 DI K7 Pipe |
| 3842 | 250 DI K7 Pipe |
| 3843 | Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers. |
| 3844 | 450 mm dia DI K7 pipes- |
| 3845 | 400 mm dia DI K7 pipes- |
| 3846 | 350 mm dia DI K7 pipes- |
| 3847 | 300 mm dia DI K7 Pipe |
| 3848 | 250 mm dia DI K7 Pipe |
| 3849 | 50mm PVC 4KSC |
| 3850 | 63mm PVC 4KSC |
| 3851 | 75mm PVC 4KSC |
| 3852 | 90mm PVC 4 KSC |
| 3853 | 110mm PVC 4KSC |
| 3854 | 140mm PVC 4KSC |
| 3855 | 160mm PVC 4KSC |
| 3856 | 200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers |
| 3857 | Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. |
| 3858 | Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP |
| 3859 | Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP |
| 3860 | Keelambur sump - 3 HP |
| 3861 | Keelambur sump -5 HP |
| 3862 | Meelambur sump - 4 HP |
| 3863 | Sivasailam sump - 3 HP |
| 3864 | Dharamapuram madam sump - 1 HP |
| 3865 | Papankulam sump - 4HP |
| 3866 | Papankulam sump - 1HP |
| 3867 | Papankulam sump - 7.5 HP |
| 3868 | Papankulam sump - 3 HP |
| 3869 | Papankulam sump - 5 HP |
| 3870 | A.P.nadanoor sump - 2HP |
| 3871 | A.P.nadanoor sump - 1HP |
| 3872 | Thuppakudi sump - 1HP |
| 3873 | Rengasamudram sump - 1HP |
| 3874 | Adaichani sump - 1HP |
| 3875 | Pallakal sump - 4HP |
| 3876 | Idaikal sump - 5HP |
| 3877 | Kabalibarai sump - 1HP |
| 3878 | Pappakudi sump - 2HP |
| 3879 | Pottalpudur sump - 1HP |
| 3880 | Pottalpudur sump - 1HP |
| 3881 | Ravanasamduram sump - 2HP |
| 3882 | Veerasamduram sump - 1HP |
| 3883 | Manthiyoor sump - 2HP |
| 3884 | Mudhaliyarpatti sump - 1HP |
| 3885 | Keelakadaiyam sump - 1HP |
| 3886 | Keelakadaiyam sump - 20HP |
| 3887 | Keelakadaiyam sump - 3HP |
| 3888 | Sarvaikaranpatti sump - 1HP |
| 3889 | Sarvaikaranpatti sump - 1HP |
| 3890 | Kadayam perumbathu sump - 1HP |
| 3891 | Kadayam perumbathu sump - 1HP |
| 3892 | Avudayanoor sump - 1HP |
| 3893 | Avudayanoor sump - 1HP |
| 3894 | Sivanadanoor sump - 1HP |
| 3895 | Sivanadanoor sump - 1HP |
| 3896 | Kallorani sump - 2HP |
| 3897 | Kulasekarapatti sump - 3HP |
| 3898 | Kulasekarapatti sump - 1HP |
| 3899 | Kulasekarapatti sump - 1HP |
| 3900 | SSK Nagar - 1HP |
| 3901 | Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE |
| 3902 | Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board. |
| 3903 | 3 core 10 Sq. mm aluminium cable |
| 3904 | 3 core 25 Sq. mm aluminium cable |
| 3905 | 3 core 50 Sq. mm aluminium cable |
| 3906 | 3 core 95 Sq. mm aluminium cable |
| 3907 | 3 core 185 Sq. mm aluminium cable |
| 3908 | 3.5 core 50 Sq. mm aluminium cable |
| 3909 | 3.5 core 95 Sq. mm aluminium cable |
| 3910 | 3.5 core 185 Sq. mm aluminium cable |
| 3911 | Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3912 | 3 core 10 Sq. mm aluminium cable |
| 3913 | 3 core 25 Sq. mm aluminium cable |
| 3914 | 3 core 50 Sq. mm aluminium cable |
| 3915 | 3 core 95 Sq. mm aluminium cable |
| 3916 | 3 core 185 Sq. mm aluminium cable |
| 3917 | 3.5 core 50 Sq. mm aluminium cable |
| 3918 | 3.5 core 95 Sq. mm aluminium cable |
| 3919 | 3.5 core 185 Sq. mm aluminium cable |
| 3920 | Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3921 | 3 core 10 Sq. mm aluminium cable |
| 3922 | 3 core 25 Sq. mm aluminium cable |
| 3923 | 3 core 50 Sq. mm aluminium cable |
| 3924 | 3 core 95 Sq. mm aluminium cable |
| 3925 | 3 core 185 Sq. mm aluminium cable |
| 3926 | 3.5 core 50 Sq. mm aluminium cable |
| 3927 | 3.5 core 95 Sq. mm aluminium cable |
| 3928 | 3.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE |
| 3929 | Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board. |
| 3930 | 3 core 4 Sq. mm copper flat cable |
| 3931 | 3 core 6 Sq. mm copper flat cable |
| 3932 | 3 core 10 Sq. mm copper flat cable |
| 3933 | Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board. |
| 3934 | 3 core 4 Sq. mm copper flat cable |
| 3935 | 3 core 6 Sq. mm copper flat cable |
| 3936 | 3 core 10 Sq. mm copper flat cable |
| 3937 | Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers |
| 3938 | 3 core 4 Sq. mm copper flat cable |
| 3939 | 3 core 6 Sq. mm copper flat cable |
| 3940 | 3 core 10 Sq. mm copper flat cable |
| 3941 | Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB |
| 3942 | 250 Amps |
| 3943 | 400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers |
| 3944 | Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers. |
| 3945 | 400 mm CI Sluice valve |
| 3946 | 350 mm CI Sluice valve |
| 3947 | 250 mm CI Sluice valve |
| 3948 | 200 mm CI Sluice valve |
| 3949 | 150 mm CI Sluice valve |
| 3950 | 125 mm CI Sluice valve |
| 3951 | 100 mm CI Sluice valve |
| 3952 | 80 mm Sluice valve |
| 3953 | 65 mm CI Sluice valve |
| 3954 | 50 mm sluice valve |
| 3955 | 150 mm CI NRV valve |
| 3956 | 125 mm CI NRV valve |
| 3957 | 100 mm CI NRV valve |
| 3958 | 80 mm CI NRV valve |
| 3959 | 65 mm CI NRV valve |
| 3960 | 50 mm CI NRV Valve |
| 3961 | 50 mm double airvalve |
| 3962 | 40 mm single airvalve |
| 3963 | 100 mm DI single chamber Air release Valve |
| 3964 | 80mm single chamber Air release Valve |
| 3965 | 50mm single chamber Air release Valve |
| 3966 | Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. |
| 3967 | Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3968 | 50 mm Gate valve |
| 3969 | 65 mm Gate valve |
| 3970 | 80 mm Gate valve |
| 3971 | 100 mm Gate valve |
| 3972 | 125 mm Gate valve |
| 3973 | Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers. |
| 3974 | 50 mm NRV |
| 3975 | 65 mm NRV |
| 3976 | 80 mm NRV COST OF CHEMICALS |
| 3977 | Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers. |
| 3978 | Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3979 | Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers. |
| 3980 | Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers. |
| 3981 | Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers |
| 3982 | Clear water sump - 400000 Litres |
| 3983 | Recirculation sump - 100000 Litre |
| 3984 | Keela Ambur - 215000 Litres |
| 3985 | Mela Ambur - - 135000 Litres |
| 3986 | Siva Sailam - - 65000 Litres |
| 3987 | Dharmapuramadam - 110000 Litres |
| 3988 | Pappankulam @ Common sump - -650000 Litres |
| 3989 | A.P.Nadanoor -- 160000 Litres |
| 3990 | Thuppakudi - - 55000 Litres |
| 3991 | Rangasamudram - 25000 Litres |
| 3992 | Adaichani - 75000 Litres |
| 3993 | Pallakal - 165000 Litres |
| 3994 | Idaikal - 155000 Litres |
| 3995 | Kabali parai - 40000 Litres |
| 3996 | Pappakudi - 95000 Litres |
| 3997 | Pottalpudur - 35000 Litres |
| 3998 | Ravanasamudram - 105000 Litres |
| 3999 | Veerasamudram - 45000 Litres |
| 4000 | Manthiyoor - 100000 Litres |
| 4001 | Mudaliarpatti - - 45000 Litres |
| 4002 | Keela Kadayam - 140000 Litres |
| 4003 | Servaikaranpatti - 50000 Litres |
| 4004 | Kadayamperum pathu - 60000 Litres |
| 4005 | S.S.K. Nagar - 15000 Litres |
| 4006 | Avudayanoor (IPP) - 60000 Litres |
| 4007 | Gunaramanallur(IPP) - 85000 Litres |
| 4008 | Kallorani(IPP) - 90000 Litres |
| 4009 | Kulasekarapatti(IPP) - 110000 Litres |
| 4010 | KEELAPAVOOR T.P - 65000 Litres Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender