Drinking Water Supply and Sanitation Local Bodies Closing in 16 days TDR #58434905

Tender For Operation And Maintenance Of The 8 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12C)

Issued by Local Bodies · Tenkasi, Tamil Nadu
Tender Value
22.56 Crore
Estimated cost
Bid Submission
07 Dec 2026
16 days left
EMD
16.92 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenkasi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Operation And Maintenance Of The 8 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12C)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Nov-2026 Amendment to Bid document Technical Bid 07-Dec-2026

BOQ

Name of Work:- Operation and maintenance of the 8 Nos of CWSS in Tenkasi District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 12C)
Sl. No. Item Description
1Operation and maintenance of the 8 Nos of CWSS in Tenkasi District including repair, rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 12C)
2CWSS TO Sencottai Municipality, 4 TPs and UTP and AND 47 Rural Habitations in Tenkasi District
3CWSS TO Keelapavur UTP, Iyathankattalai and 31 Habitations in Kadayam & Keelapavoor Union in Tenkasi District
4CWSS TO Ayikudi, Achampudur, Vadakarai, Kilpadugai, Panpozhi and 151 Rural habitations in Kadayam, Keelapavoor, Tenkasi and Schencottai Union in Tenkasi District
5CWSS TO Tenkasi MPTY, Courtallam, Ilanji and Melagaram TP in Tenkasi District
6CWSS TO Venkadampatti - Poolankulam in Tenkasi District
7Augmentation of WSS to 147 rural habitations under Sankarankoil and Alangulam CWSS in Tirunelveli District
8CWSS TO 31 Habitations in Alangulam Union in Tenkasi District
9CWSS TO Keelapavoor Town Panchayat ( PART) and 163 Rural Habitations in Kadayam ( PART) Pappakudi ( PART ), Keelapavoor ( PART ) Unions in Tenkasi District
10Total Basic Value
11Add GST @18% on Basic Value
122.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
13Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 748.80 ML (8.32*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
14Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
15PSC Pipes of various sizes
16Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
17400 mm dia PSC Pipe
18450 mm dia PSC Pipe
19500 mm dia PSC Pipe
20Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
21400 mm dia PSC Pipe
22450 mm dia PSC Pipe
23500 mm dia PSC Pipe
24Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
25400 mm PSC Pipe
26450 mm PSC Pipe
27500 mm PSC Pipe
28Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
29400 mm PSC Pipe
30450 mm PSC Pipe
31500 mm PSC Pipe
32Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
33PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
34Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
35400 mm MS Pipe
36450 mm MS Pipe
37500 mm MS Pipe
38Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
39400 mm MS Pipe
40450 mm MS Pipe
41500 mm MS Pipe
42Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
43400mm MS pipe
44450mm MS pipe
45500mm MS pipe
46Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
47400mm MS pipe
48450mm MS pipe
49500mm MS pipe
50Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
51400mm MS pipe
52400mm Machine end
53450mm MS pipe
54450mm Machine end
55500mm MS pipe
56500mm Machine end
57Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
58400mm MS pipe
59450mm MS pipe
60500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
61Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
62For PVC Pipes of various sizes
63For AC Pipes of various sizes
64For PSC Pipes of various sizes
65Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
6663mm PVC 4 KSC
6775mm PVC 4 KSC
6890mm PVC 4 KSC
69110mm PVC 4KSC
70140mm PVC 4KSC
71160mm PVC 4KSC
72Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
73150 mm AC Pipes Class 15
74200 mm AC Pipes Class 15
75Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
76406.4 mm x 4 mm thick MS PIPE
77457 mm x 4 mm thick MS PIPE
78508 mm x 5 mm thick MS PIPE
79Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
8063 mm PVC Coupler Fabricated 4 KSC
8175 mm PVC Coupler Fabricated 4 KSC
8290 mm PVC Coupler Fabricated 4 KSC
83110 mm PVC Coupler Fabricated 4 KSC
84140 mm PVC Coupler Fabricated 4 KSC
85160 mm PVC Coupler Fabricated 4 KSC
86Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
87150 mm AC Pipes Class 15
88200 mm AC Pipes Class 15
89Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
90400 mm dia PSC Pipe
91450 mm dia PSC Pipe
92500 mm dia PSC Pipe
93Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
9463mm PVC 4KSC
9575mm PVC 4KSC
9690mm PVC 4 KSC
97110mm PVC 4KSC
98140mm PVC 4KSC
99160mm PVC 4KSC
100150 mm dia AC Class 15 Pipe
101200 mm dia AC Class 15 Pipe
102400 mm PSC Pipes
103450 mm PSC Pipes
104500 mm PSC Pipes
105Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
10650 mm GI Pipe
10765 mm GI Pipe
10880 mm GI Pipe
109100 mm GI Pipe
110Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
11150 mm GI Pipe
11265 mm GI Pipe
11380 mm GI Pipe
114100 mm GI Pipe
115Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
11650 mm GI Pipe
11765 mm GI Pipe
11880 mm GI Pipe
119100 mm GI Pipe
120Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
12150 mm GI Pipe
12265 mm GI Pipe
12380 mm GI Pipe
124100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
125Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
126Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well .
127Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room
128Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room
129Pottalpudur sump
130Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
131Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
132Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
133Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
134Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
135Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP
136Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
137Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
138Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram
139Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room
140Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
141Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room
142Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
143Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
144Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM
145Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam
146Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI
147Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos
148Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU
149Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set
150Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room
151Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
152Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
153Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
154Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB
155400 Amps
15663 Amps
157250 Amps
15832 Amps
159160 Amps
1603 Pole MCCB
16132 Amps
16263 Amps
163100 Amps
164200 Amps
165Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
1669 Amps\440V
16712 Amps\440V
16818 Amps\440V
16925 Amps\440V
17032 Amps\440V
17140 Amps\440V
17245 Amps\440V
17370 Amps\440V
17495 Amps\440V
175140 Amps\440V
176550 Amps\440V
177Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
178Upto 5A
179Upto 5A-10A
180Upto 10A-20A
181Upto 20A-30A
182Upto 30A-50A
183Upto 50A-75A
184Upto 75A-110A
185Upto 200A-300A
186Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers
187Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers.
188Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
189Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
190Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
191Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
192Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
193Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
194Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
195Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
196Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
197Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
198Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
199Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
200Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
201Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
202Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
203Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
204Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
205Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
206Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
207Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
208Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
209Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
210Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
211Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
212Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
213Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
214Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
215Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
216Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
217Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
218Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
219Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
220Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
221Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
222Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
223Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
224For 2 HP Starter - 1No
225For 3 HP Starter - 1 No
226For 5 HP Starter - 1 No
227Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
228For 7.5 HP Starter - 1No
229For 10 HP Starter - 1No
230For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
231Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
232500 mm CI Sluice valve
233400 mm CI Sluice valve
234250 mm CI Scour valve
235300 mm CI Sluice valve
236300 mm CI NRV valve
237200 mm CI Sluice valve
238200 mm CI NRV valve
239150 mm CI Sluice valve
240150 mm CI NRV valve
241100 mm CI Sluice valve
242100 mm CI NRV valve
243Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
24450 mm Gate valve
24565 mm Gate valve
24680 mm Gate valve
247100 mm Gate valve
248Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
249Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
250Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
251Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
252Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
2535.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram
2543.5 LL capacity of sump @ shencottai
2551.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu
2560.15 LL capacity of sump @ Schenkottai
2570.15 LL capacity of sump @ Shencottai For the year 2026-27 (From 01.04.2027 to 31.03.2028) For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
258Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3036.80 ML (8.32*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
259Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
260PSC Pipes of various sizes
261Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
262400 mm dia PSC Pipe
263450 mm dia PSC Pipe
264500 mm dia PSC Pipe
265Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
266400 mm dia PSC Pipe
267450 mm dia PSC Pipe
268500 mm dia PSC Pipe
269Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
270400 mm PSC Pipe
271450 mm PSC Pipe
272500 mm PSC Pipe
273Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
274400 mm PSC Pipe
275450 mm PSC Pipe
276500 mm PSC Pipe
277Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
278PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
279Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
280400 mm MS Pipe
281450 mm MS Pipe
282500 mm MS Pipe
283Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
284400 mm MS Pipe
285450 mm MS Pipe
286500 mm MS Pipe
287Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
288400mm MS pipe
289450mm MS pipe
290500mm MS pipe
291Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
292400mm MS pipe
293450mm MS pipe
294500mm MS pipe
295Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
296400mm MS pipe
297400mm Machine end
298450mm MS pipe
299450mm Machine end
300500mm MS pipe
301500mm Machine end
302Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
303400mm MS pipe
304450mm MS pipe
305500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
306Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
307For PVC Pipes of various sizes
308For AC Pipes of various sizes
309For PSC Pipes of various sizes
310Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
31163mm PVC 4 KSC
31275mm PVC 4 KSC
31390mm PVC 4 KSC
314110mm PVC 4KSC
315140mm PVC 4KSC
316160mm PVC 4KSC
317Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
318150 mm AC Pipes Class 15
319200 mm AC Pipes Class 15
320Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
321406.4 mm x 4 mm thick MS PIPE
322457 mm x 4 mm thick MS PIPE
323508 mm x 5 mm thick MS PIPE
324Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
32563 mm PVC Coupler Fabricated 4 KSC
32675 mm PVC Coupler Fabricated 4 KSC
32790 mm PVC Coupler Fabricated 4 KSC
328110 mm PVC Coupler Fabricated 4 KSC
329140 mm PVC Coupler Fabricated 4 KSC
330160 mm PVC Coupler Fabricated 4 KSC
331Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
332150 mm AC Pipes Class 15
333200 mm AC Pipes Class 15
334Supply and delivery of Burst Arresting Flexible SS Clamps of wrap around Single section type upto 500mm diameter and maxi range double section type beyond 500mm OD of all rigid pipe sections. The clamp made of stainless steel SS304 metallic body of 0.8 to 1.0mm maximum thickness pasted with waffle gaskets of Natural / Nitrile / EPDM grade ( BS EN681-1) and fitted with self stabilizing finger type clamps of 200mm length SG grade malleable cast iron duly powder coated (BS2789 grade 400/12 ) and connected through fasteners of EN8 material with Zinc Coating ( BS 970 ) . Suitable width of the clamps to be decided by the Engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by TWAD Board officers.
335400 mm dia PSC Pipe
336450 mm dia PSC Pipe
337500 mm dia PSC Pipe
338Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
33963mm PVC 4KSC
34075mm PVC 4KSC
34190mm PVC 4 KSC
342110mm PVC 4KSC
343140mm PVC 4KSC
344160mm PVC 4KSC
345150 mm dia AC Class 15 Pipe
346200 mm dia AC Class 15 Pipe
347400 mm PSC Pipes
348450 mm PSC Pipes
349500 mm PSC Pipes
350Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
35150 mm GI Pipe
35265 mm GI Pipe
35380 mm GI Pipe
354100 mm GI Pipe
355Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
35650 mm GI Pipe
35765 mm GI Pipe
35880 mm GI Pipe
359100 mm GI Pipe
360Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
36150 mm GI Pipe
36265 mm GI Pipe
36380 mm GI Pipe
364100 mm GI Pipe
365Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
36650 mm GI Pipe
36765 mm GI Pipe
36880 mm GI Pipe
369100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
370Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
371Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well .
372Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room
373Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room
374Pottalpudur sump
375Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
376Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
377Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
378Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
379Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
380Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP
381Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
382Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
383Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram
384Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room
385Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
386Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room
387Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
388Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
389Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM
390Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam
391Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI
392Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos
393Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU
394Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set
395Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room
396Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
397Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
398Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
399Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB
400400 Amps
40163 Amps
402250 Amps
40332 Amps
404160 Amps
4053 Pole MCCB
40632 Amps
40763 Amps
408100 Amps
409200 Amps
410Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
4119 Amps\440V
41212 Amps\440V
41318 Amps\440V
41425 Amps\440V
41532 Amps\440V
41640 Amps\440V
41745 Amps\440V
41870 Amps\440V
41995 Amps\440V
420140 Amps\440V
421550 Amps\440V
422Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
423Upto 5A
424Upto 5A-10A
425Upto 10A-20A
426Upto 20A-30A
427Upto 30A-50A
428Upto 50A-75A
429Upto 75A-110A
430Upto 200A-300A
431Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers
432Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers.
433Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
434Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
435Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
436Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
437Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
438Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
439Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
440Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
441Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
442Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
443Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
444Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
445Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
446Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
447Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
448Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
449Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
450Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
451Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
452Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
453Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
454Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
455Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
456Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
457Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
458Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
459Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
460Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
461Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
462Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
463Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
464Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
465Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
466Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
467Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
468Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
469For 2 HP Starter - 1No
470For 3 HP Starter - 1 No
471For 5 HP Starter - 1 No
472Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
473For 7.5 HP Starter - 1No
474For 10 HP Starter - 1No
475For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
476Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
477500 mm CI Sluice valve
478400 mm CI Sluice valve
479250 mm CI Scour valve
480300 mm CI Sluice valve
481300 mm CI NRV valve
482200 mm CI Sluice valve
483200 mm CI NRV valve
484150 mm CI Sluice valve
485150 mm CI NRV valve
486100 mm CI Sluice valve
487100 mm CI NRV valve
488Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
48950 mm Gate valve
49065 mm Gate valve
49180 mm Gate valve
492100 mm Gate valve
493Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
494Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
495Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
496Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
497Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
4985.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram
4993.5 LL capacity of sump @ shencottai
5001.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu
5010.15 LL capacity of sump @ Schenkottai
5020.15 LL capacity of sump @ Shencottai For the year 2028-29 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
503Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.32 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3036.80 ML (8.32*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
504Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
505PSC Pipes of various sizes
506Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
507400 mm dia PSC Pipe
508450 mm dia PSC Pipe
509500 mm dia PSC Pipe
510Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
511400 mm dia PSC Pipe
512450 mm dia PSC Pipe
513500 mm dia PSC Pipe
514Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
515400 mm PSC Pipe
516450 mm PSC Pipe
517500 mm PSC Pipe
518Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
519400 mm PSC Pipe
520450 mm PSC Pipe
521500 mm PSC Pipe
522Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
523PSC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
524Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
525400 mm MS Pipe
526450 mm MS Pipe
527500 mm MS Pipe
528Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
529400 mm MS Pipe
530450 mm MS Pipe
531500 mm MS Pipe
532Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
533400mm MS pipe
534450mm MS pipe
535500mm MS pipe
536Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
537400mm MS pipe
538450mm MS pipe
539500mm MS pipe
540Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
541400mm MS pipe
542400mm Machine end
543450mm MS pipe
544450mm Machine end
545500mm MS pipe
546500mm Machine end
547Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
548400mm MS pipe
549450mm MS pipe
550500mm MS pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
551Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
552For PVC Pipes of various sizes
553For AC Pipes of various sizes
554For PSC Pipes of various sizes
555Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
55663mm PVC 4 KSC
55775mm PVC 4 KSC
55890mm PVC 4 KSC
559110mm PVC 4KSC
560140mm PVC 4KSC
561160mm PVC 4KSC
562Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
563150 mm AC Pipes Class 15
564200 mm AC Pipes Class 15
565Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
566406.4 mm x 4 mm thick MS PIPE
567457 mm x 4 mm thick MS PIPE
568508 mm x 5 mm thick MS PIPE
569Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
57063 mm PVC Coupler Fabricated 4 KSC
57175 mm PVC Coupler Fabricated 4 KSC
57290 mm PVC Coupler Fabricated 4 KSC
573110 mm PVC Coupler Fabricated 4 KSC
574140 mm PVC Coupler Fabricated 4 KSC
575160 mm PVC Coupler Fabricated 4 KSC
576Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
577150 mm AC Pipes Class 15
578200 mm AC Pipes Class 15
579Supply and delivery of Burst Arresting Flexible SS Clamps of wrap around Single section type upto 500mm diameter and maxi range double section type beyond 500mm OD of all rigid pipe sections. The clamp made of stainless steel SS304 metallic body of 0.8 to 1.0mm maximum thickness pasted with waffle gaskets of Natural / Nitrile / EPDM grade ( BS EN681-1) and fitted with self stabilizing finger type clamps of 200mm length SG grade malleable cast iron duly powder coated (BS2789 grade 400/12 ) and connected through fasteners of EN8 material with Zinc Coating ( BS 970 ) . Suitable width of the clamps to be decided by the Engineer incharge at site depending on the nature of pipe crack etc., complete and as directed by TWAD Board officers.
580400 mm dia PSC Pipe
581450 mm dia PSC Pipe
582500 mm dia PSC Pipe
583Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
58463mm PVC 4KSC
58575mm PVC 4KSC
58690mm PVC 4 KSC
587110mm PVC 4KSC
588140mm PVC 4KSC
589160mm PVC 4KSC
590150 mm dia AC Class 15 Pipe
591200 mm dia AC Class 15 Pipe
592400 mm PSC Pipes
593450 mm PSC Pipes
594500 mm PSC Pipes
595Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
59650 mm GI Pipe
59765 mm GI Pipe
59880 mm GI Pipe
599100 mm GI Pipe
600Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
60150 mm GI Pipe
60265 mm GI Pipe
60380 mm GI Pipe
604100 mm GI Pipe
605Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
60650 mm GI Pipe
60765 mm GI Pipe
60880 mm GI Pipe
609100 mm GI Pipe
610Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
61150 mm GI Pipe
61265 mm GI Pipe
61380 mm GI Pipe
614100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
615Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
616Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set (1221 LPM X 15 M) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at urkaduHead Works in Infiltration Well .
617Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (8548 lpm x61 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Head Works Pump Room
618Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 8548 lpm x 61 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Urakadu Head Works Pump Room
619Pottalpudur sump
620Rewinding of motor and repair works to 170 HP centrifugal HSC Motor (7362 lpm x70 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
621Repair and reconditioning works in 170 HP HSC centrifugal Pump ( 7362 lpm x 70 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
622Rewinding of motor and reconditioning pump and repair works to 10HP Submercible Pump set ( 424 lpm x 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
623Rewinding of motor and reconditioning pump and repair works to 5HP Submercible Pump set (357 lpm x 24 m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
624Rewinding of motor and reconditioning pump and repair works to3HP Submercible Pump set (75 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room
625Rewinding of motor and reconditioning pump and repair works to2HP Submercible Pump set (50 lpm x60 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at PottalpudurPump Room MADHAPURAM SUMP
626Rewinding of motor and repair works to 175 HP centrifugal HSC Motor (7192 lpm x66 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
627Repair and reconditioning works in 175 HP HSC centrifugal Pump ( 7192 lpm x 66 m Head ) including cost of all material excluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Pottalpudur Pump Room
628Rewinding of motor and reconditioning pump and repair works to3 HP centrifugal Monobloc Pump set ( 161 LPM X 25M HEAD) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram
629Rewinding of motor and reconditioning pump and repair works to1HP Submercible Pump set (75 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Madhapuram Pump Room Kudiyiruppu pump room
630Rewinding of motor and repair works to 75HP centrifugal HSC Motor (5650 lpm x40 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor at Pump Room
631Repair and reconditioning works in 75 HP HSC centrifugal Pump ( 5650 lpm x40 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump at Kudiyiruppu Pump Room
632Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 358lpm x 40m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
633Rewinding of motor and reconditioning pump and repair works to 7.5HP centrifugal Monobloc Pump set ( 944lpm x 21m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to Coutrallam
634Rewinding of motor and reconditioning pump and repair works to 5HP centrifugal Monobloc Pump set ( 240lpm x38m )including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Kudiyiruppu Pump Room to way side habitations SUMP AT VALLAM
635Rewinding of motor and reconditioning pump and repair works to 7.5 HP (566LPM x 26M Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam
636Rewinding of motor and reconditioning pump and repair works to 7.5 HP (412LPM x 39m) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vallam SUMP AT SHENKOTTAI
637Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set ( 221 LPM X 48M Head 0t including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set - 2 nos
638Rewinding of motor and reconditioning pump and repair works to 7.5 HP centrifugal Monobloc Pump set (626 Lpm x 21M Head)including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Sump at KATTALAIKUDIYIRUUPU
639Rewinding of motor and reconditioning pump and repair works to 15 HP (650Lpm x 45m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set
640Rewinding of motor and reconditioning pump and repair works to 15 HP ( 596 Lpm x 51m Head) centrifugal Monobloc Pump set including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Board at Oorkadu Head works Pump room
641Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
642Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
643Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
644Replacement of 32-400 Amps 4 Pole & 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 4 Pole MCCB
645400 Amps
64663 Amps
647250 Amps
64832 Amps
649160 Amps
6503 Pole MCCB
65132 Amps
65263 Amps
653100 Amps
654200 Amps
655Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
6569 Amps\440V
65718 Amps\440V
65825 Amps\440V
65932 Amps\440V
66040 Amps\440V
66145 Amps\440V
66270 Amps\440V
66395 Amps\440V
664140 Amps\440V
665550 Amps\440V
666Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
667Upto 5A
668Upto 5A-10A
669Upto 10A-20A
670Upto 20A-30A
671Upto 30A-50A
672Upto 50A-75A
673Upto 75A-110A
674Upto 200A-300A
675Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers
676Electric Motor protection device against dry running. The device should protect the motor against Dry running. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply etc., complete and as directed by TWAD Board Officers.
677Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
678Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
679Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
680Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
681Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
682Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
683Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
684Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
685Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
686Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
687Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
688Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
689Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
690Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
691Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
692Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
693Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
694Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
695Labour charges for dismantling of 315 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
696Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
697Supply and delivery of LV 433V Copper windings for 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
698Supply and delivery of 3 phase insulation to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
699Supply and delivery of new transformer oil to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
700Supply and delivery of 11KV HV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
701Supply and delivery of 433KV LV Bushing with metal parts to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
702Supply and delivery of silica gel breather to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
703Supply and delivery of Capillary type thermometer including accessories to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
704Supply and delivery of gasket & oil seals to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
705Supply and delivery of paint to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
706Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
707Charges for transformer tank cleaning and painting work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
708Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
709Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 315 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
710Labour charges for Re rection of 315 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
711Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
712Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
713For 2 HP Starter - 1No
714For 3 HP Starter - 1 No
715For 5 HP Starter - 1 No
716Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). two level guard worth and auto start facility worth etc complete and as directed by TWAD Board Officers.
717For 7.5 HP Starter - 1No
718For 10 HP Starter - 1No
719For 15 HP Starter - 1No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
720Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
721500 mm CI Sluice valve
722400 mm CI Sluice valve
723250 mm CI Scour valve
724300 mm CI Sluice valve
725300 mm CI NRV valve
726200 mm CI Sluice valve
727200 mm CI NRV valve
728150 mm CI Sluice valve
729150 mm CI NRV valve
730100 mm CI Sluice valve
731100 mm CI NRV valve
732Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
73350 mm Gate valve
73465 mm Gate valve
73580 mm Gate valve
736100 mm Gate valve
737Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
738Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
739Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
740Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
741Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
7425.00 LL capacity of sump @ head works,Pottalpudur,Madhapuram
7433.5 LL capacity of sump @ shencottai
7441.00 LL capacity of sump @ Vallam and Kattalaikudiyiruupu
7450.15 LL capacity of sump @ Schenkottai
7460.15 LL capacity of sump @ Shencottai
7472.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
748Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 166.5 ML (1.85*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
749Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
750AC Pipes of various sizes
751Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
752200 mm dia AC Pipe
753250 mm dia AC Pipe
754Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
755200 mm dia AC Pipe
756250 mm dia AC Pipe
757Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
758200 mm dia AC Pipe
759250 mm dia AC Pipe
760Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
761200 mm dia AC Pipe
762250 mm dia AC Pipe
763Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
764AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
765Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
766For PVC Pipes of various sizes
767For AC Pipes of various sizes
768Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
76963mm PVC 4 KSC
77075mm PVC 4 KSC
77190mm PVC 4 KSC
772110mm PVC 4KSC
773140mm PVC 4KSC
774Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
775200 mm AC Pipes Class 15
776250 mm AC Pipes Class 15
777Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
77863 mm PVC Coupler Fabricated 4 KSC
77975 mm PVC Coupler Fabricated 4 KSC
78090 mm PVC Coupler Fabricated 4 KSC
781110 mm PVC Coupler Fabricated 4 KSC
782140 mm PVC Coupler Fabricated 4 KSC
783Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
784200 mm AC Pipes Class 15
785250 mm AC Pipes Class 15
786Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
78763mm PVC 4KSC
78875mm PVC 4KSC
78990mm PVC 4 KSC
790110mm PVC 4KSC
791140mm PVC 4KSC
792200 mm dia AC Class 15 Pipe
793250 mm dia AC Class 15 Pipe
794Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
79550 mm GI Pipe
79665 mm GI Pipe
79780 mm GI Pipe
798100 mm GI Pipe
799Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
80050 mm GI Pipe
80165 mm GI Pipe
80280 mm GI Pipe
803100 mm GI Pipe
804Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
80550 mm GI Pipe
80665 mm GI Pipe
80780 mm GI Pipe
808100 mm GI Pipe
809Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
81050 mm GI Pipe
81165 mm GI Pipe
81280 mm GI Pipe
813100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS
814Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW
815Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
816Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
817Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works
818Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump
819Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur -
820Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur
821Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai
822Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur
823Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump
824Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT
825Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP
826Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP
827Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room
828Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board.
829Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
830Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
831Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
83232 Amps 3 Pole MCCB
83363 Amps 3 Pole MCCB
834100 Amps 3 Pole MCCB
835200 Amps 3 Pole MCCB
836Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
8379 Amps\440V
83812 Amps\440V
83925 Amps\440V
84045 Amps\440V
84170 Amps\440V
842Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
843Upto 5A
844Upto 5A-10A
845Upto 20A-30A
846Upto 30A-50A
847Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
848For 2 HP Starter -1 No
849For 3 HP Starter - -1 No
850For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
851Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
852250 mm CI Sluice valve
853150 mm CI Sluice valve
854250 mm CI NRV valve
855150 mm CI NRV valve
856100 mm Air valve
85780 mm Air valve
858Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
85950 mm Gate valve
86080 mm Gate valve
861100 mm Gate valve
862Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS
863Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
864Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
865Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
8661.50 LL capacity of sump @Pappankulam, Thekumadathur
8671.00 LL capacity of sump @ Keelapavoor For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
868Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 675.25 ML (1.85*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
869Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
870AC Pipes of various sizes
871Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
872200 mm dia AC Pipe
873250 mm dia AC Pipe
874Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
875200 mm dia AC Pipe
876250 mm dia AC Pipe
877Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
878200 mm dia AC Pipe
879250 mm dia AC Pipe
880Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
881200 mm dia AC Pipe
882250 mm dia AC Pipe
883Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
884AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
885Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
886For PVC Pipes of various sizes
887For AC Pipes of various sizes
888Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
88963mm PVC 4 KSC
89075mm PVC 4 KSC
89190mm PVC 4 KSC
892110mm PVC 4KSC
893140mm PVC 4KSC
894Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
895200 mm AC Pipes Class 15
896250 mm AC Pipes Class 15
897Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
89863 mm PVC Coupler Fabricated 4 KSC
89975 mm PVC Coupler Fabricated 4 KSC
90090 mm PVC Coupler Fabricated 4 KSC
901110 mm PVC Coupler Fabricated 4 KSC
902140 mm PVC Coupler Fabricated 4 KSC
903Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
904200 mm AC Pipes Class 15
905250 mm AC Pipes Class 15
906Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
90763mm PVC 4KSC
90875mm PVC 4KSC
90990mm PVC 4 KSC
910110mm PVC 4KSC
911140mm PVC 4KSC
912200 mm dia AC Class 15 Pipe
913250 mm dia AC Class 15 Pipe
914Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
91550 mm GI Pipe
91665 mm GI Pipe
91780 mm GI Pipe
918100 mm GI Pipe
919Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
92050 mm GI Pipe
92165 mm GI Pipe
92280 mm GI Pipe
923100 mm GI Pipe
924Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
92550 mm GI Pipe
92665 mm GI Pipe
92780 mm GI Pipe
928100 mm GI Pipe
929Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
93050 mm GI Pipe
93165 mm GI Pipe
93280 mm GI Pipe
933100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS
934Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW
935Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
936Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
937Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works
938Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump
939Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur -
940Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur
941Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai
942Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur
943Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump
944Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT
945Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP
946Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP
947Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room
948Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board.
949Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
950Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
951Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
95232 Amps 3 Pole MCCB
95363 Amps 3 Pole MCCB
954100 Amps 3 Pole MCCB
955200 Amps 3 Pole MCCB
956Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
9579 Amps\440V
95812 Amps\440V
95925 Amps\440V
96045 Amps\440V
96170 Amps\440V
962Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
963Upto 5A
964Upto 5A-10A
965Upto 20A-30A
966Upto 30A-50A
967Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
968For 2 HP Starter -1 No
969For 3 HP Starter - -1 No
970For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
971Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
972250 mm CI Sluice valve
973150 mm CI Sluice valve
974250 mm CI NRV valve
975150 mm CI NRV valve
976100 mm Jet Air valve
97780 mm Jet Air valve
978Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
97950 mm Gate valve
98080 mm Gate valve
981100 mm Gate valve
982Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS
983Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
984Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
985Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
9861.50 LL capacity of sump @Pappankulam, Thekumadathur
9871.00 LL capacity of sump @ Keelapavoor For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
988Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.85 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 675.25 ML (1.85*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
989Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
990AC Pipes of various sizes
991Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
992200 mm dia AC Pipe
993250 mm dia AC Pipe
994Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
995200 mm dia AC Pipe
996250 mm dia AC Pipe
997Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
998200 mm dia AC Pipe
999250 mm dia AC Pipe
1000Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1001200 mm dia AC Pipe
1002250 mm dia AC Pipe
1003Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1004AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1005Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1006For PVC Pipes of various sizes
1007For AC Pipes of various sizes
1008Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
100963mm PVC 4 KSC
101075mm PVC 4 KSC
101190mm PVC 4 KSC
1012110mm PVC 4KSC
1013140mm PVC 4KSC
1014Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1015200 mm AC Pipes Class 15
1016250 mm AC Pipes Class 15
1017Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
101863 mm PVC Coupler Fabricated 4 KSC
101975 mm PVC Coupler Fabricated 4 KSC
102090 mm PVC Coupler Fabricated 4 KSC
1021110 mm PVC Coupler Fabricated 4 KSC
1022140 mm PVC Coupler Fabricated 4 KSC
1023Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
1024200 mm AC Pipes Class 15
1025250 mm AC Pipes Class 15
1026Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
102763mm PVC 4KSC
102875mm PVC 4KSC
102990mm PVC 4 KSC
1030110mm PVC 4KSC
1031140mm PVC 4KSC
1032200 mm dia AC Class 15 Pipe
1033250 mm dia AC Class 15 Pipe
1034Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
103550 mm GI Pipe
103665 mm GI Pipe
103780 mm GI Pipe
1038100 mm GI Pipe
1039Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
104050 mm GI Pipe
104165 mm GI Pipe
104280 mm GI Pipe
1043100 mm GI Pipe
1044Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
104550 mm GI Pipe
104665 mm GI Pipe
104780 mm GI Pipe
1048100 mm GI Pipe
1049Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
105050 mm GI Pipe
105165 mm GI Pipe
105280 mm GI Pipe
1053100 mm GI Pipe REPAIR AND RECONDITIONING L OF PUMPSETS
1054Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Pappankulam HW
1055Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 578 LPM X 19 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1056Rewinding of motor and repair works to 30 HP centrifugal HSC Motor (1615 X 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1057Repair and reconditioning of 30 HP centrifugal HSC Pump (1615 X 51 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works
1058Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (119 lpm x 48 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Ravoothaperi Therkumadathur sump
1059Rewinding of motor and repair works to 20 HP centrifugal HSC Motor (964 X 24 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at T.Madathur -
1060Repair and reconditioning of 20 HP centrifugal HSC Pump (964 X 24 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at T.Madathur
1061Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 254 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Iythankattalai
1062Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets (150 lpm x 30 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Muppuliyur
1063Rewinding of motor and reconditioning pump and repair works to 5HP Submersible Pump set (247 lpm x 53m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Salaiputhur Keelapavoor sump
1064Rewinding of motor and reconditioning pump and repair works to 5 HP Centrifugal Monobloc Pumpsets ( 484 lpm x 21 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapavoor Union PT
1065Rewinding of motor and reconditioning pump and repair works to 3 HP Centrifugal Monobloc Pumpsets ( 335 lpm x 23 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Nagalkulam & Keelapvoor RTP
1066Rewinding of motor and reconditioning pump and repair works to 2 HP Centrifugal Monobloc Pumpsets ( 145 lpm x 19 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Keelapvoor TP
1067Attending cable fault for Infiltration well for 5 HP Submersible motor to main panel board at pappankulam Head works pump room
1068Supply, delivery of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated and steel Armoured copper cable as per I.S.1554 for following Wells submersible motor to main panel board.
1069Laying of 1.1 KV Grade 3 core 10 Sq. mm PVC insulated steel Armoured copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1070Jonting the 1.1KV grade 3 Core 10 SQ mm PVC Insulated Steel armoured copper cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1071Replacement of 32-200 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
107232 Amps 3 Pole MCCB
107363 Amps 3 Pole MCCB
1074100 Amps 3 Pole MCCB
1075200 Amps 3 Pole MCCB
1076Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
10779 Amps\440V
107825 Amps\440V
107945 Amps\440V
108070 Amps\440V
1081Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1082Upto 5A
1083Upto 5A-10A
1084Upto 20A-30A
1085Upto 30A-50A
1086Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
1087For 2 HP Starter -1 No
1088For 3 HP Starter - -1 No
1089For 5 HP Starter - 1 No Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1090Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve/ Air Valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1091250 mm CI Sluice valve
1092150 mm CI Sluice valve
1093250 mm CI NRV valve
1094150 mm CI NRV valve
1095100 mm Jet Air valve
109680 mm Jet Air valve
1097Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
109850 mm Gate valve
109980 mm Gate valve
1100100 mm Gate valve
1101Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers. COST OF CHEMICALS
1102Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1103Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1104Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
11051.50 LL capacity of sump @Pappankulam, Thekumadathur
11061.00 LL capacity of sump @ Keelapavoor
11072.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
1108Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 750.60 ML (8.34*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1109Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1110PSC Pipes of various sizes
1111AC Pipes of various sizes
1112Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1113350 mm dia PSC Pipe
1114400 mm dia PSC Pipe
1115450 mm dia PSC Pipe
1116500 mm dia PSC Pipe
1117600 mm dia PSC Pipe
1118200 mm dia AC Pipe
1119250 mm dia AC Pipe
1120Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1121350 mm dia PSC Pipe
1122400 mm dia PSC Pipe
1123450 mm dia PSC Pipe
1124500 mm dia PSC Pipe
1125600 mm dia PSC Pipe
1126200 mm dia AC Pipe
1127250 mm dia AC Pipe
1128Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1129350 mm dia PSC Pipe
1130400 mm dia PSC Pipe
1131450 mm dia PSC Pipe
1132500 mm dia PSC Pipe
1133600 mm dia PSC Pipe
1134200 mm dia AC Pipe
1135250 mm dia AC Pipe
1136Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1137350 mm dia PSC Pipe
1138400 mm dia PSC Pipe
1139450 mm dia PSC Pipe
1140500 mm dia PSC Pipe
1141600 mm dia PSC Pipe
1142200 mm dia AC Pipe
1143250 mm dia AC Pipe
1144Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1145PSC Pipes of various sizes
1146AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
1147Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1148350 mm MS Pipe
1149400 mm MS Pipe
1150450 mm MS Pipe
1151500 mm MS Pipe
1152600 mm MS Pipe
1153Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1154350 mm MS Pipe
1155400 mm MS Pipe
1156450 mm MS Pipe
1157500 mm MS Pipe
1158600 mm MS Pipe
1159Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
1160350 mm MS Pipe
1161400 mm MS Pipe
1162450 mm MS Pipe
1163500 mm MS Pipe
1164600 mm MS Pipe
1165Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
1166350 mm MS Pipe
1167400 mm MS Pipe
1168450 mm MS Pipe
1169500 mm MS Pipe
1170600 mm MS Pipe
1171Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
1172350mm MS pipe
1173350mm Machine end
1174400mm MS pipe
1175400mm Machine end
1176450mm MS pipe
1177450mm Machine end
1178500mm MS pipe
1179500mm Machine end
1180600mm MS pipe
1181600mm Machine end
1182Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1183350 mm MS Pipe
1184400 mm MS Pipe
1185450 mm MS Pipe
1186500 mm MS Pipe
1187600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1188Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1189For PVC Pipes of various sizes
1190For AC Pipes of various sizes
1191For PSC Pipes of various sizes
1192Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
119350mm PVC 6 KSC
119463mm PVC 4 KSC
119575mm PVC 4 KSC
119690mm PVC 4 KSC
1197110mm PVC 4KSC
1198140mm PVC 4KSC
1199160mm PVC 4KSC
1200Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1201200 mm AC Pipes Class 15
1202250 mm AC Pipes Class 15
1203Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1204355.6 mm x 4 mm thick MS PIPE
1205406.4 mm x 4 mm thick MS PIPE
1206457 mm x 4 mm thick MS PIPE
1207508 mm x 5 mm thick MS PIPE
1208610 mm x 5.8 mm thick MS PIPE
1209Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
121050 mm PVC Coupler Fabricated 6 KSC
121163 mm PVC Coupler Fabricated 4 KSC
121275 mm PVC Coupler Fabricated 4 KSC
121390 mm PVC Coupler Fabricated 4 KSC
1214110 mm PVC Coupler Fabricated 4 KSC
1215140 mm PVC Coupler Fabricated 4 KSC
1216160 mm PVC Coupler Fabricated 4 KSC
1217Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
1218200 mm AC Pipes Class 15
1219250 mm AC Pipes Class 15
1220Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
1221350 mm dia PSC Pipe
1222400 mm dia PSC Pipe
1223450 mm dia PSC Pipe
1224500 mm dia PSC Pipe
1225600 mm dia PSC Pipe
1226Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
122750mm PVC 6KSC
122863mm PVC 4KSC
122975mm PVC 4KSC
123090mm PVC 4 KSC
1231110mm PVC 4KSC
1232140mm PVC 4KSC
1233160mm PVC 4KSC
1234200 mm dia AC Class 15 Pipe
1235250 mm dia AC Class 15 Pipe
1236350 mm PSC Pipes
1237400 mm PSC Pipes
1238450 mm PSC Pipes
1239500 mm PSC Pipes
1240600 mm PSC Pipes
1241Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
124250 mm GI Pipe
124365 mm GI Pipe
124480 mm GI Pipe
1245100 mm GI Pipe
1246Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
124750 mm GI Pipe
124865 mm GI Pipe
124980 mm GI Pipe
1250100 mm GI Pipe
1251Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
125250 mm GI Pipe
125365 mm GI Pipe
125480 mm GI Pipe
1255100 mm GI Pipe
1256Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
125750 mm GI Pipe
125865 mm GI Pipe
125980 mm GI Pipe
1260100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
1261Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works
1262Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1263Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1264Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump
1265Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor
1266Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump
1267Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1268Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1269Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1270Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1271Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram
1272Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP
1273Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1274Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1275Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai
1276Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar
1277Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room
1278Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar
1279Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by )
1280Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No
1281Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP
1282Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP
1283Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP
1284Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur
1285Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump
1286Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump
1287Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump
1288Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP
1289Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi
1290Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti
1291Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump
1292Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump
1293Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar
1294Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump
1295Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump
1296Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP
1297Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur
1298Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump
1299Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP
1300Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu
1301Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump
1302Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump
1303Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu
1304Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump
1305Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump
1306Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump
1307Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump
1308Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump
1309Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room
1310Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
1311Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1312Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1313Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
13143 Pole MCCB
131532 Amps
131663 Amps
1317100 Amps
1318150 Amps
1319200 Amps
1320400 Amps
1321600 Amps
1322Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
13239 Amps\440V
132412 Amps\440V
132518 Amps\440V
132625 Amps\440V
1327140 Amps\440V
1328550 Amps\440V
1329Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1330Upto 5A
1331Upto 5A-10A
1332Upto 10A-20A
1333Upto 50A-75A
1334Upto 75A-110A
1335Upto 200A-300A
1336Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
1337Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1338Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1339Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1340Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1341Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1342Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1343Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1344Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1345Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1346Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1347Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1348Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1349Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1350Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1351Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1352Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1353Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1354Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
1355For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1356Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1357600mm CI sluice valve
1358450 mm CI Sluice valve
1359400 mm CI Sluice valve
1360350 mm CI Sluice valve
1361300 mm CI Scour valve
1362250 mm CI Scour valve
1363200 mm CI scover valve
1364350 mm CI NRV
1365250 mm CI NRV
1366200 mm CI NRV
1367150 mm Double Chamber Air Release Valve
1368100 mm Double Chamber Air Release Valve
136980 mm Double Chamber Air Release Valve
1370Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
137150 mm Gate valve
137265 mm Gate valve
137380 mm Gate valve
1374100 mm Gate valve
1375Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty
137650 mm Single chamber air release Valve
137780 mm Single chamber air release Valve
1378100 mm Single chamber air release Valve
1379Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1380Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1381Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1382Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1383Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
13846.00 LL capacity of sump @ head works, Veikalipatti, Kavoor
13854.00 LL capacity of sump @ Mathalamparai, Vanjinagar
13862.00 LL capacity of sump @ Panozhi
13871.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram
13880.70 LL capacity of sump @ Melapavoor
13890.45 LL capacity of sump @ Kulasekarapatti
13900.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani
13910.20 LL capacity of sump @ PP Valasai, Pattakurichi
13920.15 LL capacity of sump @ Anna nagar, Parumbu
1393Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI)
1394Inflitration well 1 to 8 Nos- Each-8 Hours For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
1395Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3044.1 ML (8.34*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1396Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1397PSC Pipes of various sizes
1398AC Pipes of various sizes
1399Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1400350 mm dia PSC Pipe
1401400 mm dia PSC Pipe
1402450 mm dia PSC Pipe
1403500 mm dia PSC Pipe
1404600 mm dia PSC Pipe
1405200 mm dia AC Pipe
1406250 mm dia AC Pipe
1407Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1408350 mm dia PSC Pipe
1409400 mm dia PSC Pipe
1410450 mm dia PSC Pipe
1411500 mm dia PSC Pipe
1412600 mm dia PSC Pipe
1413200 mm dia AC Pipe
1414250 mm dia AC Pipe
1415Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1416350 mm dia PSC Pipe
1417400 mm dia PSC Pipe
1418450 mm dia PSC Pipe
1419500 mm dia PSC Pipe
1420600 mm dia PSC Pipe
1421200 mm dia AC Pipe
1422250 mm dia AC Pipe
1423Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1424350 mm dia PSC Pipe
1425400 mm dia PSC Pipe
1426450 mm dia PSC Pipe
1427500 mm dia PSC Pipe
1428600 mm dia PSC Pipe
1429200 mm dia AC Pipe
1430250 mm dia AC Pipe
1431Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1432PSC Pipes of various sizes
1433AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
1434Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1435350 mm MS Pipe
1436400 mm MS Pipe
1437450 mm MS Pipe
1438500 mm MS Pipe
1439600 mm MS Pipe
1440Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1441350 mm MS Pipe
1442400 mm MS Pipe
1443450 mm MS Pipe
1444500 mm MS Pipe
1445600 mm MS Pipe
1446Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
1447350 mm MS Pipe
1448400 mm MS Pipe
1449450 mm MS Pipe
1450500 mm MS Pipe
1451600 mm MS Pipe
1452Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
1453350 mm MS Pipe
1454400 mm MS Pipe
1455450 mm MS Pipe
1456500 mm MS Pipe
1457600 mm MS Pipe
1458Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
1459350mm MS pipe
1460350mm Machine end
1461400mm MS pipe
1462400mm Machine end
1463450mm MS pipe
1464450mm Machine end
1465500mm MS pipe
1466500mm Machine end
1467600mm MS pipe
1468600mm Machine end
1469Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1470350 mm MS Pipe
1471400 mm MS Pipe
1472450 mm MS Pipe
1473500 mm MS Pipe
1474600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1475Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1476For PVC Pipes of various sizes
1477For AC Pipes of various sizes
1478For PSC Pipes of various sizes
1479Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
148050mm PVC 6 KSC
148163mm PVC 4 KSC
148275mm PVC 4 KSC
148390mm PVC 4 KSC
1484110mm PVC 4KSC
1485140mm PVC 4KSC
1486160mm PVC 4KSC
1487Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1488200 mm AC Pipes Class 15
1489250 mm AC Pipes Class 15
1490Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1491355.6 mm x 4 mm thick MS PIPE
1492406.4 mm x 4 mm thick MS PIPE
1493457 mm x 4 mm thick MS PIPE
1494508 mm x 5 mm thick MS PIPE
1495610 mm x 5.8 mm thick MS PIPE
1496Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
149750 mm PVC Coupler Fabricated 6 KSC
149863 mm PVC Coupler Fabricated 4 KSC
149975 mm PVC Coupler Fabricated 4 KSC
150090 mm PVC Coupler Fabricated 4 KSC
1501110 mm PVC Coupler Fabricated 4 KSC
1502140 mm PVC Coupler Fabricated 4 KSC
1503160 mm PVC Coupler Fabricated 4 KSC
1504Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
1505200 mm AC Pipes Class 15
1506250 mm AC Pipes Class 15
1507Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
1508350 mm dia PSC Pipe
1509400 mm dia PSC Pipe
1510450 mm dia PSC Pipe
1511500 mm dia PSC Pipe
1512600 mm dia PSC Pipe
1513Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
151450mm PVC 6KSC
151563mm PVC 4KSC
151675mm PVC 4KSC
151790mm PVC 4 KSC
1518110mm PVC 4KSC
1519140mm PVC 4KSC
1520160mm PVC 4KSC
1521200 mm dia AC Class 15 Pipe
1522250 mm dia AC Class 15 Pipe
1523350 mm PSC Pipes
1524400 mm PSC Pipes
1525450 mm PSC Pipes
1526500 mm PSC Pipes
1527600 mm PSC Pipes
1528Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
152950 mm GI Pipe
153065 mm GI Pipe
153180 mm GI Pipe
1532100 mm GI Pipe
1533Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
153450 mm GI Pipe
153565 mm GI Pipe
153680 mm GI Pipe
1537100 mm GI Pipe
1538Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
153950 mm GI Pipe
154065 mm GI Pipe
154180 mm GI Pipe
1542100 mm GI Pipe
1543Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
154450 mm GI Pipe
154565 mm GI Pipe
154680 mm GI Pipe
1547100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
1548Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works
1549Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1550Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1551Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump
1552Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor
1553Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump
1554Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1555Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1556Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1557Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1558Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram
1559Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP
1560Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1561Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1562Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai
1563Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar
1564Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room
1565Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar
1566Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by )
1567Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No
1568Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP
1569Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP
1570Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP
1571Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur
1572Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump
1573Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump
1574Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump
1575Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP
1576Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi
1577Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti
1578Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump
1579Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump
1580Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar
1581Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump
1582Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump
1583Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP
1584Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur
1585Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump
1586Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP
1587Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu
1588Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump
1589Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump
1590Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu
1591Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump
1592Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump
1593Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump
1594Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump
1595Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump
1596Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai
1597Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room
1598Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
1599Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1600Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1601Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
16023 Pole MCCB
160332 Amps
160463 Amps
1605100 Amps
1606150 Amps
1607200 Amps
1608400 Amps
1609600 Amps
1610Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
16119 Amps\440V
161212 Amps\440V
161318 Amps\440V
161425 Amps\440V
1615140 Amps\440V
1616550 Amps\440V
1617Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1618Upto 5A
1619Upto 5A-10A
1620Upto 10A-20A
1621Upto 50A-75A
1622Upto 75A-110A
1623Upto 200A-300A
1624Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
1625Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1626Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1627Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1628Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1629Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1630Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1631Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1632Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1633Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1634Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1635Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1636Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1637Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1638Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1639Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1640Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1641Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1642Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
1643For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1644Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1645600mm CI sluice valve
1646450 mm CI Sluice valve
1647400 mm CI Sluice valve
1648350 mm CI Sluice valve
1649300 mm CI Scour valve
1650250 mm CI Scour valve
1651200 mm CI scover valve
1652350 mm CI NRV
1653250 mm CI NRV
1654200 mm CI NRV
1655150 mm Double Chamber Air Release Valve
1656100 mm Double Chamber Air Release Valve
165780 mm Double Chamber Air Release Valve
1658Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
165950 mm Gate valve
166065 mm Gate valve
166180 mm Gate valve
1662100 mm Gate valve
1663Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty
166450 mm Single chamber air release Valve
166580 mm Single chamber air release Valve
1666100 mm Single chamber air release Valve
1667Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1668Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1669Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1670Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1671Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
16726.00 LL capacity of sump @ head works, Veikalipatti, Kavoor
16734.00 LL capacity of sump @ Mathalamparai, Vanjinagar
16742.00 LL capacity of sump @ Panozhi
16751.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram
16760.70 LL capacity of sump @ Melapavoor
16770.45 LL capacity of sump @ Kulasekarapatti
16780.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani
16790.20 LL capacity of sump @ PP Valasai, Pattakurichi
16800.15 LL capacity of sump @ Anna nagar, Parumbu
1681Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI)
1682Inflitration well 1 to 8 Nos- Each-8 Hours For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
1683Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.34 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 3044.1 ML (8.34*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1684Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1685PSC Pipes of various sizes
1686AC Pipes of various sizes
1687Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1688350 mm dia PSC Pipe
1689400 mm dia PSC Pipe
1690450 mm dia PSC Pipe
1691500 mm dia PSC Pipe
1692600 mm dia PSC Pipe
1693200 mm dia AC Pipe
1694250 mm dia AC Pipe
1695Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1696350 mm dia PSC Pipe
1697400 mm dia PSC Pipe
1698450 mm dia PSC Pipe
1699500 mm dia PSC Pipe
1700600 mm dia PSC Pipe
1701200 mm dia AC Pipe
1702250 mm dia AC Pipe
1703Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1704350 mm dia PSC Pipe
1705400 mm dia PSC Pipe
1706450 mm dia PSC Pipe
1707500 mm dia PSC Pipe
1708600 mm dia PSC Pipe
1709200 mm dia AC Pipe
1710250 mm dia AC Pipe
1711Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1712350 mm dia PSC Pipe
1713400 mm dia PSC Pipe
1714450 mm dia PSC Pipe
1715500 mm dia PSC Pipe
1716600 mm dia PSC Pipe
1717200 mm dia AC Pipe
1718250 mm dia AC Pipe
1719Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1720PSC Pipes of various sizes
1721AC Pipes of various sizes Attending leaks in the pipelines of this CWSS for the following items as per the standard procedure including earthwork excavation , dewatering , removing , relaying, jointing civil works, cost of materials and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers
1722Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of AC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1723350 mm MS Pipe
1724400 mm MS Pipe
1725450 mm MS Pipe
1726500 mm MS Pipe
1727600 mm MS Pipe
1728Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1729350 mm MS Pipe
1730400 mm MS Pipe
1731450 mm MS Pipe
1732500 mm MS Pipe
1733600 mm MS Pipe
1734Hire charges for welding unit including cost of welding rod,gas unit for cutting,fabrication of MS pipes and specials including Transportation,loading unloading and all other charges.
1735350 mm MS Pipe
1736400 mm MS Pipe
1737450 mm MS Pipe
1738500 mm MS Pipe
1739600 mm MS Pipe
1740Hire charges for Generator for electric current for attending leaks including light fuel, crew, Transportation,loading unloading and all other charges etc., complete and as directed by TWAD Board officers.
1741350 mm MS Pipe
1742400 mm MS Pipe
1743450 mm MS Pipe
1744500 mm MS Pipe
1745600 mm MS Pipe
1746Supply and Delivery of MS specials as per IS 7322-1985 without inside lining and outside coating inclusive of transporation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
1747350mm MS pipe
1748350mm Machine end
1749400mm MS pipe
1750400mm Machine end
1751450mm MS pipe
1752450mm Machine end
1753500mm MS pipe
1754500mm Machine end
1755600mm MS pipe
1756600mm Machine end
1757Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1758350 mm MS Pipe
1759400 mm MS Pipe
1760450 mm MS Pipe
1761500 mm MS Pipe
1762600 mm MS Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1763Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1764For PVC Pipes of various sizes
1765For AC Pipes of various sizes
1766For PSC Pipes of various sizes
1767Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
176850mm PVC 6 KSC
176963mm PVC 4 KSC
177075mm PVC 4 KSC
177190mm PVC 4 KSC
1772110mm PVC 4KSC
1773140mm PVC 4KSC
1774160mm PVC 4KSC
1775Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
1776200 mm AC Pipes Class 15
1777250 mm AC Pipes Class 15
1778Supply and Delivery of MS bare pipes of the following dimensions as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001 and other allied codes including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1779355.6 mm x 4 mm thick MS PIPE
1780406.4 mm x 4 mm thick MS PIPE
1781457 mm x 4 mm thick MS PIPE
1782508 mm x 5 mm thick MS PIPE
1783610 mm x 5.8 mm thick MS PIPE
1784Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
178550 mm PVC Coupler Fabricated 6 KSC
178663 mm PVC Coupler Fabricated 4 KSC
178775 mm PVC Coupler Fabricated 4 KSC
178890 mm PVC Coupler Fabricated 4 KSC
1789110 mm PVC Coupler Fabricated 4 KSC
1790140 mm PVC Coupler Fabricated 4 KSC
1791160 mm PVC Coupler Fabricated 4 KSC
1792Supply and Delivery of CID Joint Class 15 inclusive of transportation charges anywhere in Tamilnadu as directed by TWAD Board officers
1793200 mm AC Pipes Class 15
1794250 mm AC Pipes Class 15
1795Supply and Delivery of MJ collars inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers
1796350 mm dia PSC Pipe
1797400 mm dia PSC Pipe
1798450 mm dia PSC Pipe
1799500 mm dia PSC Pipe
1800600 mm dia PSC Pipe
1801Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
180250mm PVC 6KSC
180363mm PVC 4KSC
180475mm PVC 4KSC
180590mm PVC 4 KSC
1806110mm PVC 4KSC
1807140mm PVC 4KSC
1808160mm PVC 4KSC
1809200 mm dia AC Class 15 Pipe
1810250 mm dia AC Class 15 Pipe
1811350 mm PSC Pipes
1812400 mm PSC Pipes
1813450 mm PSC Pipes
1814500 mm PSC Pipes
1815600 mm PSC Pipes
1816Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
181750 mm GI Pipe
181865 mm GI Pipe
181980 mm GI Pipe
1820100 mm GI Pipe
1821Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
182250 mm GI Pipe
182365 mm GI Pipe
182480 mm GI Pipe
1825100 mm GI Pipe
1826Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
182750 mm GI Pipe
182865 mm GI Pipe
182980 mm GI Pipe
1830100 mm GI Pipe
1831Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
183250 mm GI Pipe
183365 mm GI Pipe
183480 mm GI Pipe
1835100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
1836Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers Sattupathu Head works
1837Rewinding of motor and reconditioning pump and repair works to 5 HP Open Well Submersible Pump Set ( 1002 LPM X 17 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
1838Rewinding of motor and repair works to180 HP centrifugal HSC Motor (8016X 72 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Head Works
1839Repair and reconditioning of 180 HP centrifugal HSC Pump ( 8016 lpm x 72m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Head works Kavoor sump
1840Rewinding of motor and repair works to100 HP centrifugal HSC Motor (8016X 42 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Kavoor
1841Repair and reconditioning 100 HP centrifugal HSC Pump (8016pm x 42m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Kavoor Veikalipatti sump
1842Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4902 lpm x 36m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1843Repair and reconditioning 60 HP centrifugal HSC Pump (4902 lpm x 36m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1844Rewinding of motor and repair works to 50 HP centrifugal HSC Motor (2736 lpm x 45m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1845Repair and reconditioning 50 HP centrifugal HSC Pump (2736 lpm x 45m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Veikalipatti
1846Rewinding of motor and reconditioning pump and repair works to 3HP Submersible Pump set (306lpm x 29m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ariyappapuram
1847Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (72lpm x14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullavanoor MATHALAMPARAI SUMP
1848Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4593 lpm x 33m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1849Repair and reconditioning 60 HP centrifugal HSC Pump (4593 lpm x 33m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Mathalamparai
1850Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (209 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pullukattuvalasai
1851Rewinding of motor and reconditioning pump and repair works to 2HP Submersible Pump set (100 lpm x 50m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Azad Nagar
1852Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (72 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mathalamparai Vanjinagar pump room
1853Rewinding of motor and repair works to 60 HP centrifugal HSC Motor (4243 lpm x 39m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Vanjinagar
1854Repair and reconditioning 60 HP centrifugal HSC Pump (4243 lpm x 39m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Vanjinagar - 2 Nos ( Including stand by )
1855Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (253 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai - 1 No
1856Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set (97 lpm x 48m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai PANPOZHI SUMP
1857Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set (1392 lpm x 18m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Vadakarai TP
1858Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (732 lpm x 14m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Panpozhi TP
1859Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set (89 lpm x 13m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Manalur
1860Rewinding of motor and reconditioning pump and repair works to 1 HP Submersible Pump set ( 30 lpm x 30 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thirumalaikovil Avudaiyanoor sump
1861Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 301 lpm x 18 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Avudaiyanoor Thippanampatti sump
1862Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set (445 lpm x 34m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Thippanampatti Pavoorchatram sump
1863Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set (1048 lpm x 44m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Keelapavoor TP
1864Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kurumalaperi
1865Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 225 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor & Kulasekarapatti
1866Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Pavoorchatram & Kamaraj nagar Kallurani sump
1867Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 249 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kallurani Parumbu sump
1868Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 153 lpm x 20 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at K.T.C Nagar
1869Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 63 lpm x 9 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kadapokathi Anna nagar sump
1870Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 272 lpm x 15 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Anna nagar Elathur sump
1871Rewinding of motor and reconditioning pump and repair works to 10 HP Submersible Pump set ( 638 lpm x 43 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Achanputhur TP
1872Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 176 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Elathur
1873Rewinding of motor and reconditioning pump and repair works to 0.5 HP Submersible Pump set ( 30 lpm x 11 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Chitra puram Annathapuram sump
1874Rewinding of motor and reconditioning pump and repair works to 7.5 HP Submersible Pump set ( 553 lpm x 37 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Ayikudi TP
1875Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 226 lpm x 16 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Agarakattu
1876Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 105 lpm x 27 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kilankadu Kottai theradu sump
1877Rewinding of motor and reconditioning pump and repair works to 5 HP Submersible Pump set ( 215 lpm x 48 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Mekarai Puliyarai sump
1878Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 90 lpm x 36 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Therkumedu
1879Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 97 lpm x 23 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Puliyarai Govindaperi sump
1880Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 45 lpm x 44 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Govindaperi Melapattakurichi sump
1881Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 70 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapattakurichi Meelapavoor sump
1882Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 125 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Melapavoor Kulasekarapatti sump
1883Rewinding of motor and reconditioning pump and repair works to 2 HP Submersible Pump set ( 100 lpm x 25 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kulasekarapatti PP Valasai sump
1884Rewinding of motor and reconditioning pump and repair works to 1.5 HP Submersible Pump set ( 38 lpm x 34 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at PP Valasai
1885Attending cable fault for infiltration well for 5 HP Submersible Motor to Main panel Board at Sattupathu Head works Pump room
1886Supply, delivery of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
1887Laying of 1.1 KV Grade 3 core 35 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
1888Jonting the 1.1KV grade 3 Core 35 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
1889Replacement of 32-600 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers.
18903 Pole MCCB
189132 Amps
189263 Amps
1893100 Amps
1894150 Amps
1895200 Amps
1896400 Amps
1897600 Amps
1898Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
18999 Amps\440V
190012 Amps\440V
190118 Amps\440V
190225 Amps\440V
1903140 Amps\440V
1904550 Amps\440V
1905Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
1906Upto 5A
1907Upto 5A-10A
1908Upto 10A-20A
1909Upto 50A-75A
1910Upto 75A-110A
1911Upto 200A-300A
1912Attending Major Repair works to 250KVA TransformerAt head works,Pottalpudur sump and Mathapuram sump HT supply
1913Labour charges for dismantling of 250 KVA Transformer with all accessories by using crane etc. complete as directed by TWAD Board officers
1914Supply and delivery of HV 11KV Copper Dual Coat Super enameled winding coils for 3 phase to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1915Supply and delivery of LV 433V Copper windings for 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1916Supply and delivery of 3 phase insulation to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1917Supply and delivery of new transformer oil to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1918Supply and delivery of 11KV HV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1919Supply and delivery of 433KV LV Bushing with metal parts to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1920Supply and delivery of silica gel breather to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1921Supply and delivery of Capillary type thermometer including accessories to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1922Supply and delivery of gasket & oil seals to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1923Supply and delivery of paint to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1924Charges for hot air chamber treatment for IR value improvement work 900c for 2 days to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1925Charges for transformer tank cleaning and painting work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1926Labour Charges new windings reassembling with new insulation off load tape switch connection load with delta star connection by copper bracing work two coatings varnish apply work to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1927Charges for attending core winding job to tank accessories fixing as per IS specification including testing work with loading to 250 KVA Transformer as per IS Specifications as directed by TWAD Board Officers
1928Labour charges for Re rection of 250 KVA Transformer and all accessories by using crane etc. complete as directed by TWAD Board officers
1929Conveyance charges for transformer head works station to work shop site and work shop site to head works station completion of rectification works etc. complete as directed by TWAD Board officers
1930Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
1931For 5 HP Starter - 5 Nos Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
1932Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
1933600mm CI sluice valve
1934450 mm CI Sluice valve
1935400 mm CI Sluice valve
1936350 mm CI Sluice valve
1937300 mm CI Scour valve
1938250 mm CI Scour valve
1939200 mm CI scover valve
1940350 mm CI NRV
1941250 mm CI NRV
1942200 mm CI NRV
1943150 mm Double Chamber Air Release Valve
1944100 mm Double Chamber Air Release Valve
194580 mm Double Chamber Air Release Valve
1946Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
194750 mm Gate valve
194865 mm Gate valve
194980 mm Gate valve
1950100 mm Gate valve
1951Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, conforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty
195250 mm Single chamber air release Valve
195380 mm Single chamber air release Valve
1954100 mm Single chamber air release Valve
1955Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
1956Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
1957Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
1958Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
1959Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
19606.00 LL capacity of sump @ head works, Veikalipatti, Kavoor
19614.00 LL capacity of sump @ Mathalamparai, Vanjinagar
19622.00 LL capacity of sump @ Panozhi
19631.00 LL capacity of sump @ Elathur, Anathapuram, Pavoorchatram
19640.70 LL capacity of sump @ Melapavoor
19650.45 LL capacity of sump @ Kulasekarapatti
19660.30 LL capacity of sump @ Thippanampatti, Avudaiyanoor, Puliyarai, Kallurani
19670.20 LL capacity of sump @ PP Valasai, Pattakurichi
19680.15 LL capacity of sump @ Anna nagar, Parumbu
1969Rate for flushing of borewell of 6\\" dia requiring less than 4 hours operation using drill rods/ hose with required size of pipes for various capacity compressor including transportation, labour, and fuel charges for compressors as directed by the TWAD Officer and conducting yield test by 'V' notch method if required 600 Cfm ( 100 /150 PSI)
1970Inflitration well 1 to 8 Nos- Each-8 Hours
19712.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
1972Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 222.30 ML (2.47*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
1973Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1974300 mm dia CI Pipe
1975Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1976300 mm dia CI Pipe
1977Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
1978300 mm dia CI Pipe
1979Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
1980300 mm dia CI Pipe
1981Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
1982300 mm dia CI Pipe
1983Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1984300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
1985Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
1986300 mm dia CI Pipe
198790mm PVC Pipe
1988Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
198990mm PVC 4 KSC
1990Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers
1991300 mm DI Pipe
1992Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
199390 mm PVC Coupler Fabricated 4 KSC
1994Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
1995300 mm DI Pipe
1996Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
1997300 mm DI Pipe
1998Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
1999300 mm DI Pipe
2000Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
200190mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS
2002Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2003Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No )
2004Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram )
2005Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2006Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2007Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram
2008Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos
2009Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
20109 Amps\440V
201112 Amps\440V
201225 Amps\440V
201350 Amps\440V
201495 Amps\440V
2015Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2016Upto 5A
2017Upto 5A-10A
2018Upto 20A-30A
2019Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2020Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2021300mm CI sluice valve
2022150 mm CI Sluice valve
2023100 mm CI Sluice valve
202480 mm CI Sluice valve
2025150 mm CI NRV valve
2026100 mm CI NRV valve
202780 mm CI NRV valve
2028Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
202950 mm Gate valve
203065 mm Gate valve
203180 mm Gate valve
2032Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2033Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2034Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2035Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
20361.25 LL capacity of sump @Kudiyarppu Clearing light jungle
2037Around SS Tank @ Kudiyarppu
2038Office Campus @Kudiyarppu
2039Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure ) For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
2040Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 901.55 ML (2.47*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2041Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2042300 mm dia CI Pipe
2043Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2044300 mm dia CI Pipe
2045Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2046300 mm dia CI Pipe
2047Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2048300 mm dia CI Pipe
2049Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2050300 mm dia CI Pipe
2051Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2052300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2053Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2054300 mm dia CI Pipe
205590mm PVC Pipe
2056Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
205790mm PVC 4 KSC
2058Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers
2059300 mm DI Pipe
2060Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
206190 mm PVC Coupler Fabricated 4 KSC
2062Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2063300 mm DI Pipe
2064Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
2065300 mm DI Pipe
2066Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2067300 mm DI Pipe
2068Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
206990mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS
2070Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2071Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No )
2072Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram )
2073Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2074Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2075Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram
2076Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos
2077Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
20789 Amps\440V
207912 Amps\440V
208025 Amps\440V
208150 Amps\440V
208295 Amps\440V
2083Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2084Upto 5A
2085Upto 5A-10A
2086Upto 20A-30A
2087Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2088Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2089300mm CI sluice valve
2090150 mm CI Sluice valve
2091100 mm CI Sluice valve
209280 mm CI Sluice valve
2093150 mm CI NRV valve
2094100 mm CI NRV valve
209580 mm CI NRV valve
2096Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
209750 mm Gate valve
209865 mm Gate valve
209980 mm Gate valve
2100Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2101Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2102Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2103Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
21041.25 LL capacity of sump @Kudiyarppu Clearing light jungle
2105Around SS Tank @ Kudiyarppu
2106Office Campus @Kudiyarppu
2107Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure ) For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
2108Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 2.47 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 901.55 ML (2.47*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2109Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2110300 mm dia CI Pipe
2111Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2112300 mm dia CI Pipe
2113Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2114300 mm dia CI Pipe
2115Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2116300 mm dia CI Pipe
2117Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2118300 mm dia CI Pipe
2119Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2120300 mm dia CI Pipe Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2121Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2122300 mm dia CI Pipe
212390mm PVC Pipe
2124Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
212590mm PVC 4 KSC
2126Supply and delivery of the following sizes of DI pipes of class 15 confirming to the IS 8329/2000 other specifications including transportation charges any where in Tamilnadu etc., complete and as directed by TWAD Board officers
2127300 mm DI Pipe
2128Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
212990 mm PVC Coupler Fabricated 4 KSC
2130Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2131300 mm DI Pipe
2132Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
2133300 mm DI Pipe
2134Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2135300 mm DI Pipe
2136Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
213790mm PVC 4 KSC REPAIR AND RECONDITIONING OF PUMPSETS
2138Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2139Rewinding of motor and repair works to 30 HP centrifugal HSC Motor ( 3100 X 24.5 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram - 1 No )
2140Repair and reconditioning of 30 HP centrifugal HSC Pump ( 3100 X 24.5 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Tenkasi Mpty & Melagaram )
2141Rewinding of motor and repair works to 12.5 HP centrifugal HSC Motor ( 1000 X 37 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2142Repair and reconditioning of 12.5 HP centrifugal HSC Pump ( 1000 X 37 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at ( Ilanji & Courtallam )
2143Rewinding of motor and reconditioning pump and repair works to 4 HP Submersible Pump set ( 166 lpm x 29 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu & Nanagaram
2144Rewinding of motor and reconditioning pump and repair works to 3 HP Submersible Pump set ( 125 lpm x 40 m) including cost of all material, conveyance ,labour charges for removing and re-erection of Submersible Pumpset set etc.., complete and as directed by TWAD Borad officers at Kudiyuruppu SS Tank Open well - 1 nos
2145Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
214612 Amps\440V
214725 Amps\440V
214850 Amps\440V
214995 Amps\440V
2150Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2151Upto 5A
2152Upto 5A-10A
2153Upto 20A-30A
2154Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2155Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2156300mm CI sluice valve
2157150 mm CI Sluice valve
2158100 mm CI Sluice valve
215980 mm CI Sluice valve
2160150 mm CI NRV valve
2161100 mm CI NRV valve
216280 mm CI NRV valve
2163Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
216450 mm Gate valve
216565 mm Gate valve
216680 mm Gate valve
2167Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2168Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2169Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2170Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
21711.25 LL capacity of sump @Kudiyarppu Clearing light jungle
2172Around SS Tank @ Kudiyarppu
2173Office Campus @Kudiyarppu
2174Removal of silt in Thenkal channel at off take point at Courtallam Hills and as directed by TWAD Board officers. ( As per Annexure )
21752.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2176Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2177AC Pipes of various sizes
2178Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2179200 mm AC of Various Classes
2180250 mm AC of Various Classes
2181Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2182200 mm AC of Various Classes
2183250 mm AC of Various Classes
2184Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2185200 mm AC of Various Classes
2186250 mm AC of Various Classes
2187Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2188200 mm AC of Various Classes
2189250 mm AC of Various Classes
2190Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2191AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2192Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2193For PVC Pipes of various sizes
2194For AC Pipes of various sizes
2195Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
219650mm PVC 6KSC
219763mm PVC 4KSC
219875mm PVC 4KSC
219990mm PVC 4 KSC
2200110mm PVC 4KSC
2201140mm PVC 4KSC
2202160mm PVC 4KSC
2203Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
2204200 mm AC Pipe Class 15
2205250 mm AC Pipe Class 15
2206Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
220750 mm PVC Coupler Fabricated 6 KSC
220863 mm PVC Coupler Fabricated 4 KSC
220975 mm PVC Coupler Fabricated 4 KSC
221090 mm PVC Coupler Fabricated 4 KSC
2211110 mm PVC Coupler Fabricated 4 KSC
2212140 mm PVC Coupler Fabricated 4 KSC
2213160 mm PVC Coupler Fabricated 4 KSC
2214Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2215200 mm AC Pipe Class 15
2216250 mm AC Pipe Class 15
2217Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
221850mm PVC 6KSC
221963mm PVC 4KSC
222075mm PVC 4KSC
222190mm PVC 4 KSC
2222110mm PVC 4KSC
2223140mm PVC 4KSC
2224160mm PVC 4KSC
2225200 mm AC Pipe Class 15
2226250 mm AC Pipe Class 15
2227Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
222850 mm GI Pipe
222965 mm GI Pipe
223080 mm GI Pipe
2231100 mm GI Pipe
2232Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
223350 mm GI Pipe
223465 mm GI Pipe
223580 mm GI Pipe
2236100 mm GI Pipe
2237Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
223850 mm GI Pipe
223965 mm GI Pipe
224080 mm GI Pipe
2241100 mm GI Pipe
2242Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
224350 mm GI Pipe
224465 mm GI Pipe
224580 mm GI Pipe
2246100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2247Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2248Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam
2249Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam
2250Vadamalaipatti Booster Station
2251Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam )
2252Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti
2253Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam
2254Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
22559 Amps\440V
225612 Amps\440V
225725 Amps\440V
225845 Amps\440V
2259Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2260Upto 5A
2261Upto 5A-10A
2262Upto 20A-30A
2263Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2264Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2265150mm CI sluice valve
2266150 mm CI NRV
2267100 mm CI NRV
2268Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
226950 mm Gate valve
2270Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
2271Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2272Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2273Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2274Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
22750.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai For the year 2027-28 (From 01.04.2027 to 31.03.2028) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2276Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2277AC Pipes of various sizes
2278Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2279200 mm AC of Various Classes
2280250 mm AC of Various Classes
2281Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2282200 mm AC of Various Classes
2283250 mm AC of Various Classes
2284Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2285200 mm AC of Various Classes
2286250 mm AC of Various Classes
2287Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2288200 mm AC of Various Classes
2289250 mm AC of Various Classes
2290Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2291AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2292Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2293For PVC Pipes of various sizes
2294For AC Pipes of various sizes
2295Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
229650mm PVC 6KSC
229763mm PVC 4KSC
229875mm PVC 4KSC
229990mm PVC 4 KSC
2300110mm PVC 4KSC
2301140mm PVC 4KSC
2302160mm PVC 4KSC
2303Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
2304200 mm AC Pipe Class 15
2305250 mm AC Pipe Class 15
2306Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
230750 mm PVC Coupler Fabricated 6 KSC
230863 mm PVC Coupler Fabricated 4 KSC
230975 mm PVC Coupler Fabricated 4 KSC
231090 mm PVC Coupler Fabricated 4 KSC
2311110 mm PVC Coupler Fabricated 4 KSC
2312140 mm PVC Coupler Fabricated 4 KSC
2313160 mm PVC Coupler Fabricated 4 KSC
2314Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2315200 mm AC Pipe Class 15
2316250 mm AC Pipe Class 15
2317Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
231850mm PVC 6KSC
231963mm PVC 4KSC
232075mm PVC 4KSC
232190mm PVC 4 KSC
2322110mm PVC 4KSC
2323140mm PVC 4KSC
2324160mm PVC 4KSC
2325200 mm AC Pipe Class 15
2326250 mm AC Pipe Class 15
2327Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
232850 mm GI Pipe
232965 mm GI Pipe
233080 mm GI Pipe
2331100 mm GI Pipe
2332Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
233350 mm GI Pipe
233465 mm GI Pipe
233580 mm GI Pipe
2336100 mm GI Pipe
2337Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
233850 mm GI Pipe
233965 mm GI Pipe
234080 mm GI Pipe
2341100 mm GI Pipe
2342Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
234350 mm GI Pipe
234465 mm GI Pipe
234580 mm GI Pipe
2346100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2347Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2348Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam
2349Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam
2350Vadamalaipatti Booster Station
2351Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam )
2352Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti
2353Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam
2354Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
23559 Amps\440V
235612 Amps\440V
235725 Amps\440V
235845 Amps\440V
2359Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2360Upto 5A
2361Upto 5A-10A
2362Upto 20A-30A
2363Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2364Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2365150mm CI sluice valve
2366150 mm CI NRV
2367100 mm CI NRV
2368Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
236950 mm Gate valve
2370Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
2371Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2372Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2373Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2374Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
23750.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai For the year 2028-29 (From 01.04.2028 to 31.03.2029) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2376Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2377AC Pipes of various sizes
2378Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2379200 mm AC of Various Classes
2380250 mm AC of Various Classes
2381Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2382200 mm AC of Various Classes
2383250 mm AC of Various Classes
2384Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2385200 mm AC of Various Classes
2386250 mm AC of Various Classes
2387Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2388200 mm AC of Various Classes
2389250 mm AC of Various Classes
2390Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2391AC Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2392Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2393For PVC Pipes of various sizes
2394For AC Pipes of various sizes
2395Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
239650mm PVC 6KSC
239763mm PVC 4KSC
239875mm PVC 4KSC
239990mm PVC 4 KSC
2400110mm PVC 4KSC
2401140mm PVC 4KSC
2402160mm PVC 4KSC
2403Supply and delivery of the following sizes of AC PRESSURE PIPES of CLASS 15 confirming to the IS 1592/2003 inclusive of transportation charges anywhere in Tamilnadu etc. complete and as directed by TWAD Board officers.
2404200 mm AC Pipe Class 15
2405250 mm AC Pipe Class 15
2406Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
240750 mm PVC Coupler Fabricated 6 KSC
240863 mm PVC Coupler Fabricated 4 KSC
240975 mm PVC Coupler Fabricated 4 KSC
241090 mm PVC Coupler Fabricated 4 KSC
2411110 mm PVC Coupler Fabricated 4 KSC
2412140 mm PVC Coupler Fabricated 4 KSC
2413160 mm PVC Coupler Fabricated 4 KSC
2414Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2415200 mm AC Pipe Class 15
2416250 mm AC Pipe Class 15
2417Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
241850mm PVC 6KSC
241963mm PVC 4KSC
242075mm PVC 4KSC
242190mm PVC 4 KSC
2422110mm PVC 4KSC
2423140mm PVC 4KSC
2424160mm PVC 4KSC
2425200 mm AC Pipe Class 15
2426250 mm AC Pipe Class 15
2427Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
242850 mm GI Pipe
242965 mm GI Pipe
243080 mm GI Pipe
2431100 mm GI Pipe
2432Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
243350 mm GI Pipe
243465 mm GI Pipe
243580 mm GI Pipe
2436100 mm GI Pipe
2437Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
243850 mm GI Pipe
243965 mm GI Pipe
244080 mm GI Pipe
2441100 mm GI Pipe
2442Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
244350 mm GI Pipe
244465 mm GI Pipe
244580 mm GI Pipe
2446100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2447Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2448Rewinding of motor and repair works to 25 HP centrifugal HSC Motor ( 1070 X 56 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Pappankulam
2449Repair and reconditioning of 25 HP centrifugal HSC Pump ( 1070 X 56 m Head ) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Pappankulam
2450Vadamalaipatti Booster Station
2451Rewinding of motor and reconditioning pump and repair works to 12.5 HP Centrifugal Monobloc Pumpsets (531 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at ( Kovilthur & Poolangulam )
2452Rewinding of motor and reconditioning pump and repair works to 10 HP Centrifugal Monobloc Pumpsets ( 345 lpm x 51 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Vengadampatti
2453Rewinding of motor and reconditioning pump and repair works to 1 HP Centrifugal Monobloc Pumpsets ( 120 lpm x 18 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Monobloc Pump set at Poolangulam
2454Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
24559 Amps\440V
245612 Amps\440V
245725 Amps\440V
245845 Amps\440V
2459Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2460Upto 5A
2461Upto 5A-10A
2462Upto 20A-30A
2463Upto 30A-50A Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2464Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2465150mm CI sluice valve
2466150 mm CI NRV
2467100 mm CI NRV
2468Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
246950 mm Gate valve
2470Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
2471Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2472Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2473Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2474Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
24750.30 LL capacity of sump @Pappankulam HW, Vadamalaipattai
24762.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
2477Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 398.70 ML (4.43*90 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2478Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2479For DI Pipes of various sizes
2480Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2481350 mm dia DI K9 pipes
2482300 mm dia DI K7 pipes
2483250 mm dia DI K7 pipes
2484200 mm dia DI K7 pipes
2485Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2486350 mm dia DI K9 pipes
2487300 mm dia DI K7 pipes
2488250 mm dia DI K7 pipes
2489200 mm dia DI K7 pipes
2490Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2491350 mm dia DI K9 pipes
2492300 mm dia DI K7 pipes
2493250 mm dia DI K7 pipes
2494200 mm dia DI K7 pipes
2495Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2496350 mm dia DI K9 pipes
2497300 mm dia DI K7 pipes
2498250 mm dia DI K7 pipes
2499200 mm dia DI K7 pipes
2500Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2501For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2502Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2503For DI Pipes of various classes
2504For PVC Pipes of various sizes
2505Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
250650mm PVC 6KSC
250763mm PVC 4KSC
250875mm PVC 4KSC
250990mm PVC 4 KSC
2510110mm PVC 4KSC
2511140mm PVC 4KSC
2512160mm PVC 4KSC
2513200mm PVC 4KSC
2514Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
2515350 mm dia DI K9 pipes
2516300 mm dia DI K7 pipes
2517250 mm dia DI K7 pipes
2518200 mm dia DI K7 pipes
2519Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
252050 mm PVC Coupler Fabricated 6 KSC
252163 mm PVC Coupler Fabricated 4 KSC
252275 mm PVC Coupler Fabricated 4 KSC
252390 mm PVC Coupler Fabricated 4 KSC
2524110 mm PVC Coupler Fabricated 4 KSC
2525140 mm PVC Coupler Fabricated 4 KSC
2526160 mm PVC Coupler Fabricated 4 KSC
2527Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2528350 mm dia DI K9 pipes
2529300 mm dia DI K7 pipes
2530250 mm dia DI K7 pipes
2531200 mm dia DI K7 pipes
2532200mm CID Joint Class 15
2533Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
2534350 mm dia DI K9 pipes
2535300 mm dia DI K7 pipes
2536250 mm dia DI K7 pipes
2537200 mm dia DI K7 pipes
253850mm PVC 6KSC
253963mm PVC 4KSC
254075mm PVC 4KSC
254190mm PVC 4 KSC
2542110mm PVC 4KSC
2543140mm PVC 4KSC
2544160mm PVC 4KSC
2545200mm PVC 4KSC
2546Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
254750 mm GI Pipe
254865 mm GI Pipe
254980 mm GI Pipe
2550100 mm GI Pipe
2551Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
255250 mm GI Pipe
255365 mm GI Pipe
255480 mm GI Pipe
2555100 mm GI Pipe
2556Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
255750 mm GI Pipe
255865 mm GI Pipe
255980 mm GI Pipe
2560100 mm GI Pipe
2561Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
256250 mm GI Pipe
256365 mm GI Pipe
256480 mm GI Pipe
2565100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2566Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2567Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
2568Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2569Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2570Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur
2571Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur
2572Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by )
2573ALANGULAM ( 5HP X 389 LPM X 25 M )
2574PUDUPATTI ( 2HP X 336 LPM X 16 M )
2575KUTHAPANCHAN (3HP X 199 LPM X 35 M )
2576ANDIPATTI ( 3HP X 360 LPM X 25 M )
2577POOLANKULAM( 2HP X 226 LPM X 28 M )
2578PETHANADARPATTI ( 2HP X 155 LPM X 24 M )
2579NALLUR ( 7.5HP X 627 LPM X 25 M )
2580SIVALARKULAM ( 1HP X 117 LPM X 15 M )
2581MARANTHAI ( 1HP X 51 LPM X 10 M )
2582AYYANARKULAM ( 1HP X 175 LPM X 15 M )
2583SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M )
2584SUBBAIAHPURAM (1HP X 16 LPM X 14 M )
2585NETTUR ( 2HP X 314 LPM X 16 M )
2586KADANGANERI ( 4HP X 614 LPM X 18 M )
2587KADUVETTI ( 1HP X 47 LPM X 13 M )
2588KAVALAKURICHI ( 4HP X 338 LPM X 22 M )
2589V.KAVALAKURICHI (4HP X 248 LPM X 36 M )
2590UTHUMALAI ( 10HP X 790 LPM X 37 M )
2591UTHUMALAI ( 5HP X 579 LPM X 12 M )
2592KANKANANKINARU ( 1HP X 203 LPM X 16 M )
2593MARUKALANKULAM ( 2HP X 266 LPM X 21 M )
2594VANNICONENDHAL ( 3HP X 442 LPM X 18 M )
2595NARIKUDI ( 2HP X 119 LPM X 33 M )
2596V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M )
2597V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M )
2598Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room
2599Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
2600Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
2601Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
26023 Pole MCCB
260363 Amps
2604100 Amps
2605150 Amps
2606250 Amps
2607320 Amps
2608Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
26099 Amps\440V
261012 Amps\440V
261118 Amps\440V
261225 Amps\440V
2613140 Amps\440V
2614Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2615Upto 5A
2616Upto 5A-10A
2617Upto 10A-20A
2618Upto 50A-75A
2619Upto 75A-110A
2620Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
2621For 1 HP Starter
2622For 3 HP Starter
2623For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2624Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2625300 mm CI Sluice valve
2626250 mm CI Sluice valve
2627125 mm CI Sluice valve
2628100 mm CI Sluice valve
262980 mm CI Sluice valve
263065 mm CI Sluice valve
263150 mm CI sluice valve
2632300 mm CI NRV valve
2633250 mm CI NRV valve
2634125 mm CI NRV valve
2635100 mm CI NRV valve
263680 mm CI NRV valve
263765 mm CI NRV valve
263850 mm CI NRV Valve
2639100 mm single Chamber air Release valve
264080 mm single Chamber air Release valve
264150 mm single Chamber air Release valve
2642Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
264350 mm Gate valve
264465 mm Gate valve
264580 mm Gate valve
2646100 mm Gate valve
2647Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
2648Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2649Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2650Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2651Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
2652Nanthanthattai 2.15 LL Sump
2653Pudupatti 1.40 LL Sump
2654Kuthapanchan 0.85 LL Sump
2655Alangulam 0.30 LL Sump
2656Andipatti 1.50 LL Sump
2657Poolankulam 0.95 LL Sump
2658Pethanadarpatti 0.65 LL Sump
2659Nallur 4.05 LL Sump
2660Sivalarkulam 0.50 LL Sump
2661Maranthai 0.25 LL Sump
2662Ayyanarkulam 0.75 LL Sump
2663Subbiahpuram 1.05 LL Sump
2664Nettur 1.30 LL Sump
2665Kadanganeri 2.55 LL Sump
2666Kaduvetti 0.20 LL Sump
2667Kavalakurichi 1.40 LL Sump
2668Vadakku Kavalakurichi 1.05 LL Sump
2669Uthumalai 2.90 LL Sump
2670Balabadraramapuram 0.85 LL Sump
2671Marukkalankulam 1.10 LL Sump
2672Vanniconendal 1.85 LL Sump
2673Narikudi 0.50 LL Sump
2674Vadakku Panavadaly 2.05 LL Sump For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
2675Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1616.15 ML (4.43*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2676Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2677For DI Pipes of various sizes
2678Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2679350 mm dia DI K9 pipes
2680300 mm dia DI K7 pipes
2681250 mm dia DI K7 pipes
2682200 mm dia DI K7 pipes
2683Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2684350 mm dia DI K9 pipes
2685300 mm dia DI K7 pipes
2686250 mm dia DI K7 pipes
2687200 mm dia DI K7 pipes
2688Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2689350 mm dia DI K9 pipes
2690300 mm dia DI K7 pipes
2691250 mm dia DI K7 pipes
2692200 mm dia DI K7 pipes
2693Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2694350 mm dia DI K9 pipes
2695300 mm dia DI K7 pipes
2696250 mm dia DI K7 pipes
2697200 mm dia DI K7 pipes
2698Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2699For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2700Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2701For DI Pipes of various classes
2702For PVC Pipes of various sizes
2703Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
270450mm PVC 6KSC
270563mm PVC 4KSC
270675mm PVC 4KSC
270790mm PVC 4 KSC
2708110mm PVC 4KSC
2709140mm PVC 4KSC
2710160mm PVC 4KSC
2711200mm PVC 4KSC
2712Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
2713350 mm dia DI K9 pipes
2714300 mm dia DI K7 pipes
2715250 mm dia DI K7 pipes
2716200 mm dia DI K7 pipes
2717Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
271850 mm PVC Coupler Fabricated 6 KSC
271963 mm PVC Coupler Fabricated 4 KSC
272075 mm PVC Coupler Fabricated 4 KSC
272190 mm PVC Coupler Fabricated 4 KSC
2722110 mm PVC Coupler Fabricated 4 KSC
2723140 mm PVC Coupler Fabricated 4 KSC
2724160 mm PVC Coupler Fabricated 4 KSC
2725Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2726350 mm dia DI K9 pipes
2727300 mm dia DI K7 pipes
2728250 mm dia DI K7 pipes
2729200 mm dia DI K7 pipes
2730200mm CID Joint Class 15
2731Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
2732350 mm dia DI K9 pipes
2733300 mm dia DI K7 pipes
2734250 mm dia DI K7 pipes
2735200 mm dia DI K7 pipes
273650mm PVC 6KSC
273763mm PVC 4KSC
273875mm PVC 4KSC
273990mm PVC 4 KSC
2740110mm PVC 4KSC
2741140mm PVC 4KSC
2742160mm PVC 4KSC
2743200mm PVC 4KSC
2744Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
274550 mm GI Pipe
274665 mm GI Pipe
274780 mm GI Pipe
2748100 mm GI Pipe
2749Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
275050 mm GI Pipe
275165 mm GI Pipe
275280 mm GI Pipe
2753100 mm GI Pipe
2754Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
275550 mm GI Pipe
275665 mm GI Pipe
275780 mm GI Pipe
2758100 mm GI Pipe
2759Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
276050 mm GI Pipe
276165 mm GI Pipe
276280 mm GI Pipe
2763100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2764Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2765Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
2766Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2767Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2768Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur
2769Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur
2770Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by )
2771ALANGULAM ( 5HP X 389 LPM X 25 M )
2772PUDUPATTI ( 2HP X 336 LPM X 16 M )
2773KUTHAPANCHAN (3HP X 199 LPM X 35 M )
2774ANDIPATTI ( 3HP X 360 LPM X 25 M )
2775POOLANKULAM( 2HP X 226 LPM X 28 M )
2776PETHANADARPATTI ( 2HP X 155 LPM X 24 M )
2777NALLUR ( 7.5HP X 627 LPM X 25 M )
2778SIVALARKULAM ( 1HP X 117 LPM X 15 M )
2779MARANTHAI ( 1HP X 51 LPM X 10 M )
2780AYYANARKULAM ( 1HP X 175 LPM X 15 M )
2781SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M )
2782SUBBAIAHPURAM (1HP X 16 LPM X 14 M )
2783NETTUR ( 2HP X 314 LPM X 16 M )
2784KADANGANERI ( 4HP X 614 LPM X 18 M )
2785KADUVETTI ( 1HP X 47 LPM X 13 M )
2786KAVALAKURICHI ( 4HP X 338 LPM X 22 M )
2787V.KAVALAKURICHI (4HP X 248 LPM X 36 M )
2788UTHUMALAI ( 10HP X 790 LPM X 37 M )
2789UTHUMALAI ( 5HP X 579 LPM X 12 M )
2790KANKANANKINARU ( 1HP X 203 LPM X 16 M )
2791MARUKALANKULAM ( 2HP X 266 LPM X 21 M )
2792VANNICONENDHAL ( 3HP X 442 LPM X 18 M )
2793NARIKUDI ( 2HP X 119 LPM X 33 M )
2794V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M )
2795V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M )
2796Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room
2797Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
2798Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
2799Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
28003 Pole MCCB
280163 Amps
2802100 Amps
2803150 Amps
2804250 Amps
2805320 Amps
2806Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
28079 Amps\440V
280812 Amps\440V
280918 Amps\440V
281025 Amps\440V
2811140 Amps\440V
2812Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
2813Upto 5A
2814Upto 5A-10A
2815Upto 10A-20A
2816Upto 50A-75A
2817Upto 75A-110A
2818Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
2819For 1 HP Starter
2820For 3 HP Starter
2821For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
2822Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
2823300 mm CI Sluice valve
2824250 mm CI Sluice valve
2825125 mm CI Sluice valve
2826100 mm CI Sluice valve
282780 mm CI Sluice valve
282865 mm CI Sluice valve
282950 mm CI sluice valve
2830300 mm CI NRV valve
2831250 mm CI NRV valve
2832125 mm CI NRV valve
2833100 mm CI NRV valve
283480 mm CI NRV valve
283565 mm CI NRV valve
283650 mm CI NRV Valve
2837100 mm single Chamber air Release valve
283880 mm single Chamber air Release valve
283950 mm single Chamber air Release valve
2840Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
284150 mm Gate valve
284265 mm Gate valve
284380 mm Gate valve
2844100 mm Gate valve
2845Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
2846Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
2847Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
2848Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
2849Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
2850Nanthanthattai 2.15 LL Sump
2851Pudupatti 1.40 LL Sump
2852Kuthapanchan 0.85 LL Sump
2853Alangulam 0.30 LL Sump
2854Andipatti 1.50 LL Sump
2855Poolankulam 0.95 LL Sump
2856Pethanadarpatti 0.65 LL Sump
2857Nallur 4.05 LL Sump
2858Sivalarkulam 0.50 LL Sump
2859Maranthai 0.25 LL Sump
2860Subbiahpuram 1.05 LL Sump
2861Nettur 1.30 LL Sump
2862Kadanganeri 2.55 LL Sump
2863Kaduvetti 0.20 LL Sump
2864Kavalakurichi 1.40 LL Sump
2865Vadakku Kavalakurichi 1.05 LL Sump
2866Uthumalai 2.90 LL Sump
2867Balabadraramapuram 0.85 LL Sump
2868Marukkalankulam 1.10 LL Sump
2869Vanniconendal 1.85 LL Sump
2870Narikudi 0.50 LL Sump
2871Vadakku Panavadaly 2.05 LL Sump For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
2872Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 4.43 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 1616.15 ML (4.43*365 days) Attending collar Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil, labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract Part II.and as directed by TWAD Board officers.
2873Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2874For DI Pipes of various sizes
2875Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2876350 mm dia DI K9 pipes
2877300 mm dia DI K7 pipes
2878250 mm dia DI K7 pipes
2879200 mm dia DI K7 pipes
2880Supply and delivery of Hard crete oil as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Board Officers
2881350 mm dia DI K9 pipes
2882300 mm dia DI K7 pipes
2883250 mm dia DI K7 pipes
2884200 mm dia DI K7 pipes
2885Supply and delivery of cement including loading, unloading and transportation charges etc., and as directed by TWAD Board Officers
2886350 mm dia DI K9 pipes
2887300 mm dia DI K7 pipes
2888250 mm dia DI K7 pipes
2889200 mm dia DI K7 pipes
2890Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete and as directed by TWAD Board officers
2891350 mm dia DI K9 pipes
2892300 mm dia DI K7 pipes
2893250 mm dia DI K7 pipes
2894200 mm dia DI K7 pipes
2895Refilling with excavated soil (other than sand) complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
2896For DI Pipes of various sizes Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
2897Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
2898For DI Pipes of various classes
2899For PVC Pipes of various sizes
2900Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transportation, insurance charges, etc., complete and as directed by TWAD Board officers.
290150mm PVC 6KSC
290263mm PVC 4KSC
290375mm PVC 4KSC
290490mm PVC 4 KSC
2905110mm PVC 4KSC
2906140mm PVC 4KSC
2907160mm PVC 4KSC
2908200mm PVC 4KSC
2909Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
2910350 mm dia DI K9 pipes
2911300 mm dia DI K7 pipes
2912250 mm dia DI K7 pipes
2913200 mm dia DI K7 pipes
2914Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
291550 mm PVC Coupler Fabricated 6 KSC
291663 mm PVC Coupler Fabricated 4 KSC
291775 mm PVC Coupler Fabricated 4 KSC
291890 mm PVC Coupler Fabricated 4 KSC
2919110 mm PVC Coupler Fabricated 4 KSC
2920140 mm PVC Coupler Fabricated 4 KSC
2921160 mm PVC Coupler Fabricated 4 KSC
2922Supply and Delivery of CID joint class 15 as directed by TWAD Board officers
2923350 mm dia DI K9 pipes
2924300 mm dia DI K7 pipes
2925250 mm dia DI K7 pipes
2926200 mm dia DI K7 pipes
2927200mm CID Joint Class 15
2928Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
2929350 mm dia DI K9 pipes
2930300 mm dia DI K7 pipes
2931250 mm dia DI K7 pipes
2932200 mm dia DI K7 pipes
293350mm PVC 6KSC
293463mm PVC 4KSC
293575mm PVC 4KSC
293690mm PVC 4 KSC
2937110mm PVC 4KSC
2938140mm PVC 4KSC
2939160mm PVC 4KSC
2940200mm PVC 4KSC
2941Supply and delivery of the following sizes of GI Pipes and specials confirming to IS other specifications as amended from time to time with ISI marking and solvent cement as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges etc. complete and as directed by TWAD Board officers.
294250 mm GI Pipe
294365 mm GI Pipe
294480 mm GI Pipe
2945100 mm GI Pipe
2946Lowering GI pipes and specials in the trenches and laying to proper grade and alignment, jointing with GI Specials and as directed by the TWAD Officers
294750 mm GI Pipe
294865 mm GI Pipe
294980 mm GI Pipe
2950100 mm GI Pipe
2951Cutting the following sizes of the GI pipes true to axis and filing smoothly and finishing the ends etc., complete and as directed by TWAD Board officers.
295250 mm GI Pipe
295365 mm GI Pipe
295480 mm GI Pipe
2955100 mm GI Pipe
2956Threading the following sizes of the GI pipes true to axis etc., complete and as directed by TWAD Board officers.
295750 mm GI Pipe
295865 mm GI Pipe
295980 mm GI Pipe
2960100 mm GI Pipe REPAIR AND RECONDITIONING OF PUMPSETS
2961Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
2962Rewinding of motor and reconditioning pump and repair works to 7.5 HP Open Well Submersible Pump Set ( 800 LPM X 14 M ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpset at Head Works in Infiltration Well
2963Rewinding of motor and repair works to 100 HP Vertical Turbine Motor ( 3212 X 94 m Head ) including cost of all material ,conveyance ,labour charges for removing and re-erection of Vertical turbine Motor etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2964Repair and reconditioning of 100 HP Vertical Turbine Pumpsets ( 3212 X 94 m Head ) including cost of all material ( exluding Bronze impeller ,SS Shaft, MS Column Pipe ),conveyance ,labour charges for removing and re-erection of Vertical turbine Pumpset etc.., complete and as directed by TWAD Borad officers at Nanthanthattai
2965Rewinding of motor and repair works to 40 HP centrifugal HSC Motor (2215 lpm x 50m Head) including cost of all material ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Motor etc.., complete and as directed by TWAD Borad officers at Nallur
2966Repair and reconditioning 40 HP centrifugal HSC Pump (2215 lpm x 50 m Head) including cost of all material exluding Bronze impeller ,conveyance ,labour charges for removing and re-erection of centrifugal HSC Pump etc.., complete and as directed by TWAD Borad officers at Nallur
2967Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations. ( Including stand by )
2968ALANGULAM ( 5HP X 389 LPM X 25 M )
2969PUDUPATTI ( 2HP X 336 LPM X 16 M )
2970KUTHAPANCHAN (3HP X 199 LPM X 35 M )
2971ANDIPATTI ( 3HP X 360 LPM X 25 M )
2972POOLANKULAM( 2HP X 226 LPM X 28 M )
2973PETHANADARPATTI ( 2HP X 155 LPM X 24 M )
2974NALLUR ( 7.5HP X 627 LPM X 25 M )
2975SIVALARKULAM ( 1HP X 117 LPM X 15 M )
2976MARANTHAI ( 1HP X 51 LPM X 10 M )
2977AYYANARKULAM ( 1HP X 175 LPM X 15 M )
2978SUBBAIAHPURAM ( 1HP X 235 LPM X 23 M )
2979SUBBAIAHPURAM (1HP X 16 LPM X 14 M )
2980NETTUR ( 2HP X 314 LPM X 16 M )
2981KADANGANERI ( 4HP X 614 LPM X 18 M )
2982KADUVETTI ( 1HP X 47 LPM X 13 M )
2983KAVALAKURICHI ( 4HP X 338 LPM X 22 M )
2984V.KAVALAKURICHI (4HP X 248 LPM X 36 M )
2985UTHUMALAI ( 10HP X 790 LPM X 37 M )
2986UTHUMALAI ( 5HP X 579 LPM X 12 M )
2987KANKANANKINARU ( 1HP X 203 LPM X 16 M )
2988MARUKALANKULAM ( 2HP X 266 LPM X 21 M )
2989VANNICONENDHAL ( 3HP X 442 LPM X 18 M )
2990NARIKUDI ( 2HP X 119 LPM X 33 M )
2991V.PANAVADALICHATRaM (4HP X 295 LPM X 30 M )
2992V.PANAVADALICHATRaM (1HP X 191 LPM X 17 M )
2993Attending cable fault for infiltration well for 7.5 HP Submersible Motor to Main Panel Board at Nanthanthattai Head works Pump room
2994Supply, delivery of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
2995Laying of 1.1 KV Grade 3 core 50 Sq. mm PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
2996Jonting the 1.1KV grade 3 Core 50 SQ mm PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers.
29973 Pole MCCB
299863 Amps
2999100 Amps
3000150 Amps
3001250 Amps
3002320 Amps
3003Supply and delivery of Electro magnetic contactors of suitable capacity in AC Three Phase rating, conforming to IS/IEC 60947-4-1. etc., complete and as directed by TWAD Board Officers
30049 Amps\440V
300512 Amps\440V
300618 Amps\440V
300725 Amps\440V
3008140 Amps\440V
3009Supply and delivery of Overload Relays: Directly operated Bimetallic Thermal overload relay which operates in case ofoverload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
3010Upto 5A
3011Upto 5A-10A
3012Upto 10A-20A
3013Upto 50A-75A
3014Upto 75A-110A
3015Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately) and as directed by TWAD Board Officers
3016For 1 HP Starter
3017For 3 HP Starter
3018For 5 HP Starter Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
3019Attending Repair , Rectification and reconditioning of CI Sluice valve / CI NRV valve including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
3020300 mm CI Sluice valve
3021250 mm CI Sluice valve
3022125 mm CI Sluice valve
3023100 mm CI Sluice valve
302480 mm CI Sluice valve
302565 mm CI Sluice valve
302650 mm CI sluice valve
3027300 mm CI NRV valve
3028250 mm CI NRV valve
3029125 mm CI NRV valve
3030100 mm CI NRV valve
303180 mm CI NRV valve
303265 mm CI NRV valve
303350 mm CI NRV Valve
3034100 mm single Chamber air Release valve
303580 mm single Chamber air Release valve
303650 mm single Chamber air Release valve
3037Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
303850 mm Gate valve
303965 mm Gate valve
304080 mm Gate valve
3041100 mm Gate valve
3042Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
3043Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
3044Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3045Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3046Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
3047Nanthanthattai 2.15 LL Sump
3048Pudupatti 1.40 LL Sump
3049Kuthapanchan 0.85 LL Sump
3050Alangulam 0.30 LL Sump
3051Andipatti 1.50 LL Sump
3052Poolankulam 0.95 LL Sump
3053Pethanadarpatti 0.65 LL Sump
3054Nallur 4.05 LL Sump
3055Sivalarkulam 0.50 LL Sump
3056Maranthai 0.25 LL Sump
3057Subbiahpuram 1.05 LL Sump
3058Nettur 1.30 LL Sump
3059Kadanganeri 2.55 LL Sump
3060Kaduvetti 0.20 LL Sump
3061Kavalakurichi 1.40 LL Sump
3062Vadakku Kavalakurichi 1.05 LL Sump
3063Uthumalai 2.90 LL Sump
3064Balabadraramapuram 0.85 LL Sump
3065Marukkalankulam 1.10 LL Sump
3066Vanniconendal 1.85 LL Sump
3067Narikudi 0.50 LL Sump
3068Vadakku Panavadaly 2.05 LL Sump
30692.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
3070Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 149.40 ML (1.66*90 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3071Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3072For HDPE Pipes of various sizes
3073Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
307450mm HDPE PN6 Pipe
307563mm HDPE PN6 Pipe
307675mm HDPE PN6 Pipe
307790mm HDPE PN6 Pipe
3078110mm HDPE PN6 Pipe
3079160mm HDPE PN6 Pipe
3080200mm HDPE PN6 Pipe
3081Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers.
308250mm HDPE PN6 Pipe
308363mm HDPE PN6 Pipe
308475mm HDPE PN6 Pipe
308590mm HDPE PN6 Pipe
3086110mm HDPE PN6 Pipe
3087160mm HDPE PN6 Pipe
3088200mm HDPE PN6 Pipe
3089Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
309050mm 90 degree bend
309163mm 90 degree bend
309275mm 90 degree bend
309390mm 90 degree bend
3094110mm 90 degree bend
3095160mm 90 degree bend
3096200mm 90 degree bend
309750mm Equal Tee
309863mm Equal Tee
309975mm Equal Tee
310090mm Equal Tee
3101110mm Equal Tee
3102160mm Equal Tee
3103200mm Equal Tee
3104Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
310550mm HDPE PN6 Pipe
310663mm HDPE PN6 Pipe
310775mm HDPE PN6 Pipe
310890mm HDPE PN6 Pipe
3109110mm HDPE PN6 Pipe
3110160mm HDPE PN6 Pipe
3111200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3112Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3113Maranthai - 7.50 HP
3114Kathapuram - 15 HP
3115Thalaisubramaniapuram - 12.50 HP
3116Nanthanthattai - 7.50 HP
3117Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
311865 mm Gate valve
3119Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
3120Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3121Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3122Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
31231.05 LL capacity of sump @ Nanthanthattai
31243.75 LL capacity of sump @ Kathapuram
31252.4 LL capacity of sump @ Thalai Subramaniyapuram
31260.45 LL capacity of sump @ Maranthai For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
3127Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 605.90 ML (1.66*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3128Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3129For HDPE Pipes of various sizes
3130Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
313150mm HDPE PN6 Pipe
313263mm HDPE PN6 Pipe
313375mm HDPE PN6 Pipe
313490mm HDPE PN6 Pipe
3135110mm HDPE PN6 Pipe
3136160mm HDPE PN6 Pipe
3137200mm HDPE PN6 Pipe
3138Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers.
313950mm HDPE PN6 Pipe
314063mm HDPE PN6 Pipe
314175mm HDPE PN6 Pipe
314290mm HDPE PN6 Pipe
3143110mm HDPE PN6 Pipe
3144160mm HDPE PN6 Pipe
3145200mm HDPE PN6 Pipe
3146Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
314750mm 90 degree bend
314863mm 90 degree bend
314975mm 90 degree bend
315090mm 90 degree bend
3151110mm 90 degree bend
3152160mm 90 degree bend
3153200mm 90 degree bend
315450mm Equal Tee
315563mm Equal Tee
315675mm Equal Tee
315790mm Equal Tee
3158110mm Equal Tee
3159160mm Equal Tee
3160200mm Equal Tee
3161Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
316250mm HDPE PN6 Pipe
316363mm HDPE PN6 Pipe
316475mm HDPE PN6 Pipe
316590mm HDPE PN6 Pipe
3166110mm HDPE PN6 Pipe
3167160mm HDPE PN6 Pipe
3168200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3169Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3170Maranthai - 7.50 HP
3171Kathapuram - 15 HP
3172Thalaisubramaniapuram - 12.50 HP
3173Nanthanthattai - 7.50 HP
3174Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
317550 mm Gate valve
3176Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
3177Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3178Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3179Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
31801.05 LL capacity of sump @ Nanthanthattai
31813.75 LL capacity of sump @ Kathapuram
31822.4 LL capacity of sump @ Thalai Subramaniyapuram
31830.45 LL capacity of sump @ Maranthai For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
3184Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 1.66 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 605.90 ML (1.66*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3185Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3186For HDPE Pipes of various sizes
3187Supply and delivery of the following sizes of HDPE pipes confirming to IS inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board officers.
318850mm HDPE PN6 Pipe
318963mm HDPE PN6 Pipe
319075mm HDPE PN6 Pipe
319190mm HDPE PN6 Pipe
3192110mm HDPE PN6 Pipe
3193160mm HDPE PN6 Pipe
3194200mm HDPE PN6 Pipe
3195Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers.
319650mm HDPE PN6 Pipe
319763mm HDPE PN6 Pipe
319875mm HDPE PN6 Pipe
319990mm HDPE PN6 Pipe
3200110mm HDPE PN6 Pipe
3201160mm HDPE PN6 Pipe
3202200mm HDPE PN6 Pipe
3203Supply of Specials for HDPE pipes as per IS 8360/1977/Part I(Reaffirmed 1992) PartII and III (Reaffirmed 2002) including transportation charges in any where in Tamilnadu etc., complete and as directed by TWAD Board officers
320450mm 90 degree bend
320563mm 90 degree bend
320675mm 90 degree bend
320790mm 90 degree bend
3208110mm 90 degree bend
3209160mm 90 degree bend
3210200mm 90 degree bend
321150mm Equal Tee
321263mm Equal Tee
321375mm Equal Tee
321490mm Equal Tee
3215110mm Equal Tee
3216160mm Equal Tee
3217200mm Equal Tee
3218Removing following the burst PVC / AC / PSC Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
321950mm HDPE PN6 Pipe
322063mm HDPE PN6 Pipe
322175mm HDPE PN6 Pipe
322290mm HDPE PN6 Pipe
3223110mm HDPE PN6 Pipe
3224160mm HDPE PN6 Pipe
3225200mm HDPE PN6 Pipe REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3226Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3227Maranthai - 7.50 HP
3228Kathapuram - 15 HP
3229Thalaisubramaniapuram - 12.50 HP
3230Nanthanthattai - 7.50 HP
3231Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
323265 mm Gate valve
3233Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
3234Desilting light or sandysoil or silt from infiltration wells below water level including the charges for special T&P and air compressor etc., complete and as directed by TWAD Board officers. COST OF CHEMICALS
3235Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3236Supply, delivery of stable Bleaching Powder anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3237Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
32381.05 LL capacity of sump @ Nanthanthattai
32393.75 LL capacity of sump @ Kathapuram
32402.4 LL capacity of sump @ Thalai Subramaniyapuram
32410.45 LL capacity of sump @ Maranthai
32422.0 For the year 2026-27 (From 01.01.2027 to 31.03.2027) OUTSOURCING IN MLD
3243Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 721.44 ML (8.016*90 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3244Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3245For DI Pipes of various sizes
3246For PVC Pipes of various sizes
3247Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
3248450 mm dia DI K7 pipes-
3249400 mm dia DI K7 pipes-
3250350 mm dia DI K7 pipes-
3251300 mm dia DI K7 Pipe
3252250 mm dia DI K7 Pipe
3253Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
325450mm PVC 6KSC
325563mm PVC 4KSC
325675mm PVC 4KSC
325790mm PVC 4 KSC
3258110mm PVC 4KSC
3259140mm PVC 4KSC
3260160mm PVC 4KSC
3261200mm PVC 4KSC
326263mm PVC 6KSC
3263110mm PVC 6KSC
3264140mm PVC 6KSC
3265200 mm PVC 6KSC
3266200 mm PVC 10KSC
3267Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
326863mm 4KSC PVC Coupler
326975mm 4KSC PVC Coupler
327090mm 4KSC PVC Coupler
3271110mm 4KSC PVC Coupler
3272140mm 4KSC PVC Coupler
3273160mm 4KSC PVC Coupler
3274200mm 4KSC PVC Coupler
327550mm 6KSC PVC Coupler
327663mm 6KSC PVC Coupler
327775mm 6KSC PVC Coupler
327890mm 6KSC PVC Coupler
3279110mm 6KSC PVC Coupler
3280160mm 6KSC PVC Coupler
3281140mm 6KSC PVC Coupler
3282200mm 6KSC PVC Coupler
328350mm 4KSC PVC bend
328463mm 4KSC PVC bend
328575mm 4KSC PVC bend
328690mm 4KSC PVC bend
3287110mm 4KSC PVC bend
3288140mm 4KSC PVC bend
3289160mm 4KSC PVC bend
3290200mm 4KSC PVC bend
329150mm 6KSC PVC bend
329263mm 6KSC PVC bend
329375mm 6KSC PVC bend
329490mm 6KSC PVC bend
3295110mm 6KSC PVC bend
3296160mm 6KSC PVC bend
3297140mm 6KSC PVC bend
3298200mm 6KSC PVC bend
329963mm 4KSC PVC Equal Tee
330075mm 4KSC PVC Equal Tee
330190mm 4KSC PVC Equal Tee
3302110mm 4KSC PVC Equal Tee
3303140mm 4KSC PVC Equal Tee
3304160mm 4KSC PVC Equal Tee
3305200mm 4KSC PVC Equal Tee
330650mm 6KSC PVC Equal Tee
330763mm 6KSC PVC Equal Tee
330875mm 6KSC PVC Equal Tee
330990mm 6KSC PVC Equal Tee
3310110mm 6KSC PVC Equal Tee
3311140mm 6KSC PVC Equal Tee
3312160mm 6KSC PVC Equal Tee
3313200mm 6KSC PVC Equal Tee
331450mm PVC MTA
331563mm PVC MTA
331675mm PVC MTA
331790mm PVC MTA
3318110mm PVC MTA
3319140mm PVC MTA
3320160mm PVC MTA
3321200mm PVC MTA
3322Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
3323For Diesel Pump set for 5 HP
3324For Diesel Pump set for 7.5 HP
3325Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers
3326450 DI K7 Pipe
3327400 DI K7 Pipe
3328350 DI K7 Pipe
3329300 DI K7 Pipe
3330250 DI K7 Pipe
3331Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
3332450 mm dia DI K7 pipes-
3333400 mm dia DI K7 pipes-
3334350 mm dia DI K7 pipes-
3335300 mm dia DI K7 Pipe
3336250 mm dia DI K7 Pipe
333750mm PVC 4KSC
333863mm PVC 4KSC
333975mm PVC 4KSC
334090mm PVC 4 KSC
3341110mm PVC 4KSC
3342140mm PVC 4KSC
3343160mm PVC 4KSC
3344200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3345Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3346Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP
3347Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP
3348Keelambur sump - 3 HP
3349Keelambur sump -5 HP
3350Meelambur sump - 4 HP
3351Sivasailam sump - 3 HP
3352Dharamapuram madam sump - 1 HP
3353Papankulam sump - 4HP
3354Papankulam sump - 1HP
3355Papankulam sump - 7.5 HP
3356Papankulam sump - 3 HP
3357Papankulam sump - 5 HP
3358A.P.nadanoor sump - 2HP
3359A.P.nadanoor sump - 1HP
3360Thuppakudi sump - 1HP
3361Rengasamudram sump - 1HP
3362Adaichani sump - 1HP
3363Pallakal sump - 4HP
3364Idaikal sump - 5HP
3365Kabalibarai sump - 1HP
3366Pappakudi sump - 2HP
3367Pottalpudur sump - 1HP
3368Pottalpudur sump - 1HP
3369Ravanasamduram sump - 2HP
3370Veerasamduram sump - 1HP
3371Manthiyoor sump - 2HP
3372Mudhaliyarpatti sump - 1HP
3373Keelakadaiyam sump - 1HP
3374Keelakadaiyam sump - 20HP
3375Keelakadaiyam sump - 3HP
3376Sarvaikaranpatti sump - 1HP
3377Sarvaikaranpatti sump - 1HP
3378Kadayam perumbathu sump - 1HP
3379Kadayam perumbathu sump - 1HP
3380Avudayanoor sump - 1HP
3381Avudayanoor sump - 1HP
3382Sivanadanoor sump - 1HP
3383Sivanadanoor sump - 1HP
3384Kallorani sump - 2HP
3385Kulasekarapatti sump - 3HP
3386Kulasekarapatti sump - 1HP
3387Kulasekarapatti sump - 1HP
3388SSK Nagar - 1HP
3389Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE
3390Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
33913 core 10 Sq. mm aluminium cable
33923 core 25 Sq. mm aluminium cable
33933 core 50 Sq. mm aluminium cable
33943 core 95 Sq. mm aluminium cable
33953 core 185 Sq. mm aluminium cable
33963.5 core 50 Sq. mm aluminium cable
33973.5 core 95 Sq. mm aluminium cable
33983.5 core 185 Sq. mm aluminium cable
3399Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
34003 core 10 Sq. mm aluminium cable
34013 core 25 Sq. mm aluminium cable
34023 core 50 Sq. mm aluminium cable
34033 core 95 Sq. mm aluminium cable
34043 core 185 Sq. mm aluminium cable
34053.5 core 50 Sq. mm aluminium cable
34063.5 core 95 Sq. mm aluminium cable
34073.5 core 185 Sq. mm aluminium cable
3408Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
34093 core 10 Sq. mm aluminium cable
34103 core 25 Sq. mm aluminium cable
34113 core 50 Sq. mm aluminium cable
34123 core 95 Sq. mm aluminium cable
34133 core 185 Sq. mm aluminium cable
34143.5 core 50 Sq. mm aluminium cable
34153.5 core 95 Sq. mm aluminium cable
34163.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE
3417Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board.
34183 core 4 Sq. mm copper flat cable
34193 core 6 Sq. mm copper flat cable
34203 core 10 Sq. mm copper flat cable
3421Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
34223 core 4 Sq. mm copper flat cable
34233 core 6 Sq. mm copper flat cable
34243 core 10 Sq. mm copper flat cable
3425Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
34263 core 4 Sq. mm copper flat cable
34273 core 6 Sq. mm copper flat cable
34283 core 10 Sq. mm copper flat cable
3429Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
3430250 Amps
3431400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
3432Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
3433400 mm CI Sluice valve
3434350 mm CI Sluice valve
3435250 mm CI Sluice valve
3436200 mm CI Sluice valve
3437150 mm CI Sluice valve
3438125 mm CI Sluice valve
3439100 mm CI Sluice valve
344080 mm Sluice valve
344165 mm CI Sluice valve
344250 mm sluice valve
3443150 mm CI NRV valve
3444125 mm CI NRV valve
3445100 mm CI NRV valve
344680 mm CI NRV valve
344765 mm CI NRV valve
344850 mm CI NRV Valve
344950 mm double airvalve
345040 mm single airvalve
3451100 mm DI single chamber Air release Valve
345280mm single chamber Air release Valve
345350mm single chamber Air release Valve
3454Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
3455Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
345650 mm Gate valve
345765 mm Gate valve
345880 mm Gate valve
3459100 mm Gate valve
3460125 mm Gate valve
3461Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
346250 mm NRV
346365 mm NRV
346480 mm NRV COST OF CHEMICALS
3465Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3466Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3467Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3468Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3469Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
3470Clear water sump - 400000 Litres
3471Recirculation sump - 100000 Litre
3472Keela Ambur - 215000 Litres
3473Mela Ambur - - 135000 Litres
3474Siva Sailam - - 65000 Litres
3475Dharmapuramadam - 110000 Litres
3476Pappankulam @ Common sump - -650000 Litres
3477A.P.Nadanoor -- 160000 Litres
3478Thuppakudi - - 55000 Litres
3479Rangasamudram - 25000 Litres
3480Adaichani - 75000 Litres
3481Pallakal - 165000 Litres
3482Idaikal - 155000 Litres
3483Kabali parai - 40000 Litres
3484Pappakudi - 95000 Litres
3485Pottalpudur - 35000 Litres
3486Ravanasamudram - 105000 Litres
3487Veerasamudram - 45000 Litres
3488Manthiyoor - 100000 Litres
3489Mudaliarpatti - - 45000 Litres
3490Keela Kadayam - 140000 Litres
3491Servaikaranpatti - 50000 Litres
3492Kadayamperum pathu - 60000 Litres
3493S.S.K. Nagar - 15000 Litres
3494Avudayanoor (IPP) - 60000 Litres
3495Gunaramanallur(IPP) - 85000 Litres
3496Kallorani(IPP) - 90000 Litres
3497Kulasekarapatti(IPP) - 110000 Litres
3498KEELAPAVOOR T.P - 65000 Litres For the year 2027-28 (From 01.04.2027 to 31.03.2028) OUTSOURCING IN MLD
3499Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 2925.84 ML (8.16*366 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3500Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3501For DI Pipes of various sizes
3502For PVC Pipes of various sizes
3503Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
3504450 mm dia DI K7 pipes-
3505400 mm dia DI K7 pipes-
3506350 mm dia DI K7 pipes-
3507300 mm dia DI K7 Pipe
3508250 mm dia DI K7 Pipe
3509Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
351050mm PVC 6KSC
351163mm PVC 4KSC
351275mm PVC 4KSC
351390mm PVC 4 KSC
3514110mm PVC 4KSC
3515140mm PVC 4KSC
3516160mm PVC 4KSC
3517200mm PVC 4KSC
351863mm PVC 6KSC
3519110mm PVC 6KSC
3520140mm PVC 6KSC
3521200 mm PVC 6KSC
3522200 mm PVC 10KSC
3523Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
352463mm 4KSC PVC Coupler
352575mm 4KSC PVC Coupler
352690mm 4KSC PVC Coupler
3527110mm 4KSC PVC Coupler
3528140mm 4KSC PVC Coupler
3529160mm 4KSC PVC Coupler
3530200mm 4KSC PVC Coupler
353150mm 6KSC PVC Coupler
353263mm 6KSC PVC Coupler
353375mm 6KSC PVC Coupler
353490mm 6KSC PVC Coupler
3535110mm 6KSC PVC Coupler
3536160mm 6KSC PVC Coupler
3537140mm 6KSC PVC Coupler
3538200mm 6KSC PVC Coupler
353950mm 4KSC PVC bend
354063mm 4KSC PVC bend
354175mm 4KSC PVC bend
354290mm 4KSC PVC bend
3543110mm 4KSC PVC bend
3544140mm 4KSC PVC bend
3545160mm 4KSC PVC bend
3546200mm 4KSC PVC bend
354750mm 6KSC PVC bend
354863mm 6KSC PVC bend
354975mm 6KSC PVC bend
355090mm 6KSC PVC bend
3551110mm 6KSC PVC bend
3552160mm 6KSC PVC bend
3553140mm 6KSC PVC bend
3554200mm 6KSC PVC bend
355563mm 4KSC PVC Equal Tee
355675mm 4KSC PVC Equal Tee
355790mm 4KSC PVC Equal Tee
3558110mm 4KSC PVC Equal Tee
3559140mm 4KSC PVC Equal Tee
3560160mm 4KSC PVC Equal Tee
3561200mm 4KSC PVC Equal Tee
356250mm 6KSC PVC Equal Tee
356363mm 6KSC PVC Equal Tee
356475mm 6KSC PVC Equal Tee
356590mm 6KSC PVC Equal Tee
3566110mm 6KSC PVC Equal Tee
3567140mm 6KSC PVC Equal Tee
3568160mm 6KSC PVC Equal Tee
3569200mm 6KSC PVC Equal Tee
357050mm PVC MTA
357163mm PVC MTA
357275mm PVC MTA
357390mm PVC MTA
3574110mm PVC MTA
3575140mm PVC MTA
3576160mm PVC MTA
3577200mm PVC MTA
3578Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
3579For Diesel Pump set for 5 HP
3580For Diesel Pump set for 7.5 HP
3581Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers
3582450 DI K7 Pipe
3583400 DI K7 Pipe
3584350 DI K7 Pipe
3585300 DI K7 Pipe
3586250 DI K7 Pipe
3587Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
3588450 mm dia DI K7 pipes-
3589400 mm dia DI K7 pipes-
3590350 mm dia DI K7 pipes-
3591300 mm dia DI K7 Pipe
3592250 mm dia DI K7 Pipe
359350mm PVC 4KSC
359463mm PVC 4KSC
359575mm PVC 4KSC
359690mm PVC 4 KSC
3597110mm PVC 4KSC
3598140mm PVC 4KSC
3599160mm PVC 4KSC
3600200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3601Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3602Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP
3603Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP
3604Keelambur sump - 3 HP
3605Keelambur sump -5 HP
3606Meelambur sump - 4 HP
3607Sivasailam sump - 3 HP
3608Dharamapuram madam sump - 1 HP
3609Papankulam sump - 4HP
3610Papankulam sump - 1HP
3611Papankulam sump - 7.5 HP
3612Papankulam sump - 3 HP
3613Papankulam sump - 5 HP
3614A.P.nadanoor sump - 2HP
3615A.P.nadanoor sump - 1HP
3616Thuppakudi sump - 1HP
3617Rengasamudram sump - 1HP
3618Adaichani sump - 1HP
3619Pallakal sump - 4HP
3620Idaikal sump - 5HP
3621Kabalibarai sump - 1HP
3622Pappakudi sump - 2HP
3623Pottalpudur sump - 1HP
3624Pottalpudur sump - 1HP
3625Ravanasamduram sump - 2HP
3626Veerasamduram sump - 1HP
3627Manthiyoor sump - 2HP
3628Mudhaliyarpatti sump - 1HP
3629Keelakadaiyam sump - 1HP
3630Keelakadaiyam sump - 20HP
3631Keelakadaiyam sump - 3HP
3632Sarvaikaranpatti sump - 1HP
3633Sarvaikaranpatti sump - 1HP
3634Kadayam perumbathu sump - 1HP
3635Kadayam perumbathu sump - 1HP
3636Avudayanoor sump - 1HP
3637Avudayanoor sump - 1HP
3638Sivanadanoor sump - 1HP
3639Sivanadanoor sump - 1HP
3640Kallorani sump - 2HP
3641Kulasekarapatti sump - 3HP
3642Kulasekarapatti sump - 1HP
3643Kulasekarapatti sump - 1HP
3644SSK Nagar - 1HP
3645Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE
3646Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
36473 core 10 Sq. mm aluminium cable
36483 core 25 Sq. mm aluminium cable
36493 core 50 Sq. mm aluminium cable
36503 core 95 Sq. mm aluminium cable
36513 core 185 Sq. mm aluminium cable
36523.5 core 50 Sq. mm aluminium cable
36533.5 core 95 Sq. mm aluminium cable
36543.5 core 185 Sq. mm aluminium cable
3655Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
36563 core 10 Sq. mm aluminium cable
36573 core 25 Sq. mm aluminium cable
36583 core 50 Sq. mm aluminium cable
36593 core 95 Sq. mm aluminium cable
36603 core 185 Sq. mm aluminium cable
36613.5 core 50 Sq. mm aluminium cable
36623.5 core 95 Sq. mm aluminium cable
36633.5 core 185 Sq. mm aluminium cable
3664Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
36653 core 10 Sq. mm aluminium cable
36663 core 25 Sq. mm aluminium cable
36673 core 50 Sq. mm aluminium cable
36683 core 95 Sq. mm aluminium cable
36693 core 185 Sq. mm aluminium cable
36703.5 core 50 Sq. mm aluminium cable
36713.5 core 95 Sq. mm aluminium cable
36723.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE
3673Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board.
36743 core 4 Sq. mm copper flat cable
36753 core 6 Sq. mm copper flat cable
36763 core 10 Sq. mm copper flat cable
3677Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
36783 core 4 Sq. mm copper flat cable
36793 core 6 Sq. mm copper flat cable
36803 core 10 Sq. mm copper flat cable
3681Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
36823 core 4 Sq. mm copper flat cable
36833 core 6 Sq. mm copper flat cable
36843 core 10 Sq. mm copper flat cable
3685Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
3686250 Amps
3687400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
3688Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
3689400 mm CI Sluice valve
3690350 mm CI Sluice valve
3691250 mm CI Sluice valve
3692200 mm CI Sluice valve
3693150 mm CI Sluice valve
3694125 mm CI Sluice valve
3695100 mm CI Sluice valve
369680 mm Sluice valve
369765 mm CI Sluice valve
369850 mm sluice valve
3699150 mm CI NRV valve
3700125 mm CI NRV valve
3701100 mm CI NRV valve
370280 mm CI NRV valve
370365 mm CI NRV valve
370450 mm CI NRV Valve
370550 mm double airvalve
370640 mm single airvalve
3707100 mm DI single chamber Air release Valve
370880mm single chamber Air release Valve
370950mm single chamber Air release Valve
3710Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
3711Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
371250 mm Gate valve
371365 mm Gate valve
371480 mm Gate valve
3715100 mm Gate valve
3716125 mm Gate valve
3717Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
371850 mm NRV
371965 mm NRV
372080 mm NRV COST OF CHEMICALS
3721Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3722Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3723Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3724Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3725Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
3726Clear water sump - 400000 Litres
3727Recirculation sump - 100000 Litre
3728Keela Ambur - 215000 Litres
3729Mela Ambur - - 135000 Litres
3730Siva Sailam - - 65000 Litres
3731Dharmapuramadam - 110000 Litres
3732Pappankulam @ Common sump - -650000 Litres
3733A.P.Nadanoor -- 160000 Litres
3734Thuppakudi - - 55000 Litres
3735Rangasamudram - 25000 Litres
3736Adaichani - 75000 Litres
3737Pallakal - 165000 Litres
3738Idaikal - 155000 Litres
3739Kabali parai - 40000 Litres
3740Pappakudi - 95000 Litres
3741Pottalpudur - 35000 Litres
3742Ravanasamudram - 105000 Litres
3743Veerasamudram - 45000 Litres
3744Manthiyoor - 100000 Litres
3745Mudaliarpatti - - 45000 Litres
3746Keela Kadayam - 140000 Litres
3747Servaikaranpatti - 50000 Litres
3748Kadayamperum pathu - 60000 Litres
3749S.S.K. Nagar - 15000 Litres
3750Avudayanoor (IPP) - 60000 Litres
3751Gunaramanallur(IPP) - 85000 Litres
3752Kallorani(IPP) - 90000 Litres
3753Kulasekarapatti(IPP) - 110000 Litres
3754KEELAPAVOOR T.P - 65000 Litres For the year 2028-29 (From 01.04.2028 to 31.03.2029) OUTSOURCING IN MLD
3755Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 8.016 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers . Totally 2925.84 ML (8.16*365 days) Attending Bursts in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II etc., complete and as directed by the TWAD Board officers.
3756Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for the following sizes of pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
3757For DI Pipes of various sizes
3758For PVC Pipes of various sizes
3759Supply and delivery of the following sizes of DI SOCKET/SPIGOT PIPES for class K7 of onfirming to the IS 8329/2000 and other specifications at site of work including loading, unloading, fright, stacking, transit and insurance, etc. complete and as directed by TWAD Board officers.
3760450 mm dia DI K7 pipes-
3761400 mm dia DI K7 pipes-
3762350 mm dia DI K7 pipes-
3763300 mm dia DI K7 Pipe
3764250 mm dia DI K7 Pipe
3765Supply and delivery of the following sizes of unplastisized PVC Rigid pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
376650mm PVC 6KSC
376763mm PVC 4KSC
376875mm PVC 4KSC
376990mm PVC 4 KSC
3770110mm PVC 4KSC
3771140mm PVC 4KSC
3772160mm PVC 4KSC
3773200mm PVC 4KSC
377463mm PVC 6KSC
3775110mm PVC 6KSC
3776140mm PVC 6KSC
3777200 mm PVC 6KSC
3778200 mm PVC 10KSC
3779Supply and delivery of following sizes of PVC Specials conforming to IS specifications at site of work including loading, unloading,transportation, insurance, etc., Complete and as directed by TWAD Bd. officers.
378063mm 4KSC PVC Coupler
378175mm 4KSC PVC Coupler
378290mm 4KSC PVC Coupler
3783110mm 4KSC PVC Coupler
3784140mm 4KSC PVC Coupler
3785160mm 4KSC PVC Coupler
3786200mm 4KSC PVC Coupler
378750mm 6KSC PVC Coupler
378863mm 6KSC PVC Coupler
378975mm 6KSC PVC Coupler
379090mm 6KSC PVC Coupler
3791110mm 6KSC PVC Coupler
3792160mm 6KSC PVC Coupler
3793140mm 6KSC PVC Coupler
3794200mm 6KSC PVC Coupler
379550mm 4KSC PVC bend
379663mm 4KSC PVC bend
379775mm 4KSC PVC bend
379890mm 4KSC PVC bend
3799110mm 4KSC PVC bend
3800140mm 4KSC PVC bend
3801160mm 4KSC PVC bend
3802200mm 4KSC PVC bend
380350mm 6KSC PVC bend
380463mm 6KSC PVC bend
380575mm 6KSC PVC bend
380690mm 6KSC PVC bend
3807110mm 6KSC PVC bend
3808160mm 6KSC PVC bend
3809140mm 6KSC PVC bend
3810200mm 6KSC PVC bend
381163mm 4KSC PVC Equal Tee
381275mm 4KSC PVC Equal Tee
381390mm 4KSC PVC Equal Tee
3814110mm 4KSC PVC Equal Tee
3815140mm 4KSC PVC Equal Tee
3816160mm 4KSC PVC Equal Tee
3817200mm 4KSC PVC Equal Tee
381850mm 6KSC PVC Equal Tee
381963mm 6KSC PVC Equal Tee
382075mm 6KSC PVC Equal Tee
382190mm 6KSC PVC Equal Tee
3822110mm 6KSC PVC Equal Tee
3823140mm 6KSC PVC Equal Tee
3824160mm 6KSC PVC Equal Tee
3825200mm 6KSC PVC Equal Tee
382650mm PVC MTA
382763mm PVC MTA
382875mm PVC MTA
382990mm PVC MTA
3830110mm PVC MTA
3831140mm PVC MTA
3832160mm PVC MTA
3833200mm PVC MTA
3834Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
3835For Diesel Pump set for 5 HP
3836For Diesel Pump set for 7.5 HP
3837Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials as directed by TWAD Board officers
3838450 DI K7 Pipe
3839400 DI K7 Pipe
3840350 DI K7 Pipe
3841300 DI K7 Pipe
3842250 DI K7 Pipe
3843Removing following the burst DI Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc complete (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
3844450 mm dia DI K7 pipes-
3845400 mm dia DI K7 pipes-
3846350 mm dia DI K7 pipes-
3847300 mm dia DI K7 Pipe
3848250 mm dia DI K7 Pipe
384950mm PVC 4KSC
385063mm PVC 4KSC
385175mm PVC 4KSC
385290mm PVC 4 KSC
3853110mm PVC 4KSC
3854140mm PVC 4KSC
3855160mm PVC 4KSC
3856200mm PVC 4KSC REPAIR AND RECONDITIONING OF PUMPSETS Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
3857Rewinding of motor and reconditioning pump and repair works to the following HP Submersible Pump Sets including cost of all material ,conveyance ,labour charges for removing and re-erection of Submersible pumpsets at the following locations.
3858Raw water Pumpset at Kodarankulam HEADWORKS - 30 HP
3859Clear water Pumpset at Kodarankulam HEADWORKS - 90 HP
3860Keelambur sump - 3 HP
3861Keelambur sump -5 HP
3862Meelambur sump - 4 HP
3863Sivasailam sump - 3 HP
3864Dharamapuram madam sump - 1 HP
3865Papankulam sump - 4HP
3866Papankulam sump - 1HP
3867Papankulam sump - 7.5 HP
3868Papankulam sump - 3 HP
3869Papankulam sump - 5 HP
3870A.P.nadanoor sump - 2HP
3871A.P.nadanoor sump - 1HP
3872Thuppakudi sump - 1HP
3873Rengasamudram sump - 1HP
3874Adaichani sump - 1HP
3875Pallakal sump - 4HP
3876Idaikal sump - 5HP
3877Kabalibarai sump - 1HP
3878Pappakudi sump - 2HP
3879Pottalpudur sump - 1HP
3880Pottalpudur sump - 1HP
3881Ravanasamduram sump - 2HP
3882Veerasamduram sump - 1HP
3883Manthiyoor sump - 2HP
3884Mudhaliyarpatti sump - 1HP
3885Keelakadaiyam sump - 1HP
3886Keelakadaiyam sump - 20HP
3887Keelakadaiyam sump - 3HP
3888Sarvaikaranpatti sump - 1HP
3889Sarvaikaranpatti sump - 1HP
3890Kadayam perumbathu sump - 1HP
3891Kadayam perumbathu sump - 1HP
3892Avudayanoor sump - 1HP
3893Avudayanoor sump - 1HP
3894Sivanadanoor sump - 1HP
3895Sivanadanoor sump - 1HP
3896Kallorani sump - 2HP
3897Kulasekarapatti sump - 3HP
3898Kulasekarapatti sump - 1HP
3899Kulasekarapatti sump - 1HP
3900SSK Nagar - 1HP
3901Keelapavoor sump - 10HP CABLE FAULT -ALUMINIUM ARMOURED CABLE
3902Supply, delivery of 1.1 KV Grade 3 core & 3.5 Core PVC insulated and steel Armoured aluminium cable as per I.S.1554 for following Wells submersible motor to main panel board.
39033 core 10 Sq. mm aluminium cable
39043 core 25 Sq. mm aluminium cable
39053 core 50 Sq. mm aluminium cable
39063 core 95 Sq. mm aluminium cable
39073 core 185 Sq. mm aluminium cable
39083.5 core 50 Sq. mm aluminium cable
39093.5 core 95 Sq. mm aluminium cable
39103.5 core 185 Sq. mm aluminium cable
3911Laying of 1.1 KV Grade 3 core & 3.5 Core PVC insulated steel Armoured aluminium cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
39123 core 10 Sq. mm aluminium cable
39133 core 25 Sq. mm aluminium cable
39143 core 50 Sq. mm aluminium cable
39153 core 95 Sq. mm aluminium cable
39163 core 185 Sq. mm aluminium cable
39173.5 core 50 Sq. mm aluminium cable
39183.5 core 95 Sq. mm aluminium cable
39193.5 core 185 Sq. mm aluminium cable
3920Jointing the 1.1KV grade 3 Core & 3.5 core PVC Insulated Steel armoured aluminum cable as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
39213 core 10 Sq. mm aluminium cable
39223 core 25 Sq. mm aluminium cable
39233 core 50 Sq. mm aluminium cable
39243 core 95 Sq. mm aluminium cable
39253 core 185 Sq. mm aluminium cable
39263.5 core 50 Sq. mm aluminium cable
39273.5 core 95 Sq. mm aluminium cable
39283.5 core 185 Sq. mm aluminium cable CABLE FAULT - COPPER FLAT CABLE
3929Supply, delivery of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type Copper cable conforming to IS 694/1990 for following Wells submersible motor to main panel board.
39303 core 4 Sq. mm copper flat cable
39313 core 6 Sq. mm copper flat cable
39323 core 10 Sq. mm copper flat cable
3933Laying of 1.1 KV Grade 3 core PVC insulated and sheathed 3 core flat type copper cable as per I.E. rules to be laid in between Well Submersible motor and main panel board.
39343 core 4 Sq. mm copper flat cable
39353 core 6 Sq. mm copper flat cable
39363 core 10 Sq. mm copper flat cable
3937Jointing of XLPE Insulated and sheathed 3 core FLAT TYPE Copper cable confirming to IS 694/1990 and as amended thereafter and as per I E Rules including Jointing materials etc complete directed by the TWAD Board officers
39383 core 4 Sq. mm copper flat cable
39393 core 6 Sq. mm copper flat cable
39403 core 10 Sq. mm copper flat cable
3941Replacement of 250 Amps & 400 Amps 3 Pole MCCB Switch in the Head works and other pumprooms inclusive of handling charges and F.O.R destination etc complete directed by the TWAD Board officers. 3 Pole MCCB
3942250 Amps
3943400 Amps Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Electro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II. etc complete and as directed by TWAD Board officers
3944Attending Repair , Rectification and reconditioning of CI Sluice / Scour Valave / NRV including cost of all materials , conveyance, labour charges for removing and re-erection etc., complete and as directed by TWAD Board officers.
3945400 mm CI Sluice valve
3946350 mm CI Sluice valve
3947250 mm CI Sluice valve
3948200 mm CI Sluice valve
3949150 mm CI Sluice valve
3950125 mm CI Sluice valve
3951100 mm CI Sluice valve
395280 mm Sluice valve
395365 mm CI Sluice valve
395450 mm sluice valve
3955150 mm CI NRV valve
3956125 mm CI NRV valve
3957100 mm CI NRV valve
395880 mm CI NRV valve
395965 mm CI NRV valve
396050 mm CI NRV Valve
396150 mm double airvalve
396240 mm single airvalve
3963100 mm DI single chamber Air release Valve
396480mm single chamber Air release Valve
396550mm single chamber Air release Valve
3966Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking etc., complete and as directed by TWAD Board Ofificers.
3967Supply, delivery and fixing of following size of Gate valves in OHT's including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
396850 mm Gate valve
396965 mm Gate valve
397080 mm Gate valve
3971100 mm Gate valve
3972125 mm Gate valve
3973Supply, delivery and fixing of following size of G.M. Non Return valves AS PER IS BS 5154 and related IS Specifications including transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Ofificers.
397450 mm NRV
397565 mm NRV
397680 mm NRV COST OF CHEMICALS
3977Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board officers.
3978Supply and delivery of Alum as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3979Supply and delivery of Lime as per IS specification (with chlorine 99.80% moisture, Na203 Hydrogen and carbon dioxide are to be Nil) including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board officers.
3980Supply, delivery of stable Liquid Chlorine anywhere in the schemes maintained by TWAD Board as per IS 1065:1989 (Grade I) and amended from time to time including freight, loading, unloading, transporation, transit insurance, all other incidental charges at site of work etc., complete and as directed by TWAD Board officers.
3981Removal of sediments and deposition of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall using wire brushes, brooms, collecting , lifting of the deposited slit particles on above the sump and washing side wall and the slab using bleaching powder etc., complete and as directed by TWAD Board officers
3982Clear water sump - 400000 Litres
3983Recirculation sump - 100000 Litre
3984Keela Ambur - 215000 Litres
3985Mela Ambur - - 135000 Litres
3986Siva Sailam - - 65000 Litres
3987Dharmapuramadam - 110000 Litres
3988Pappankulam @ Common sump - -650000 Litres
3989A.P.Nadanoor -- 160000 Litres
3990Thuppakudi - - 55000 Litres
3991Rangasamudram - 25000 Litres
3992Adaichani - 75000 Litres
3993Pallakal - 165000 Litres
3994Idaikal - 155000 Litres
3995Kabali parai - 40000 Litres
3996Pappakudi - 95000 Litres
3997Pottalpudur - 35000 Litres
3998Ravanasamudram - 105000 Litres
3999Veerasamudram - 45000 Litres
4000Manthiyoor - 100000 Litres
4001Mudaliarpatti - - 45000 Litres
4002Keela Kadayam - 140000 Litres
4003Servaikaranpatti - 50000 Litres
4004Kadayamperum pathu - 60000 Litres
4005S.S.K. Nagar - 15000 Litres
4006Avudayanoor (IPP) - 60000 Litres
4007Gunaramanallur(IPP) - 85000 Litres
4008Kallorani(IPP) - 90000 Litres
4009Kulasekarapatti(IPP) - 110000 Litres
4010KEELAPAVOOR T.P - 65000 Litres Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58434905
AUTHORITY Local Bodies
TENDER VALUE 22.56 Crore
LAST DATE 07-12-2026
Authority
Authority Name Tamil Nadu Water Supply And Drainage Board
Work Description Tender for Operation And Maintenance Of The 8 Nos Of Cwss In Tenkasi District Including Repair, Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 12C)
Basic Detail
Tender No Operation and Maintenance of the 8 Nos. of CWSS in Tenkasi District Package 12 C
Bidding Type Tender
Location
City Tenkasi
State Tamil Nadu
Key Dates
Publish Date 11 Nov 2026
Submission Date 07 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 22.56 Crore
Tender Fee Ref. Documents
EMD 16.92 Lakhs
Exemption Not Available
Document List
504a2d67-243e-423c-82a0-c2a033eb4915.html
BIDTenkasi12C.pdf
BOQ_869174.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

504a2d67-243e-423c-82a0-c2a033eb4915.html

pdf

BIDTenkasi12C.pdf

xls

BOQ_869174.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender