Drinking Water Supply and Sanitation Local Bodies Closing in 13 days TDR #58434873

Tender For Operation And Maintenance Of The Andipatty - Sedapatty Cwss In Madurai And Theni Districts Including Repair And Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 15 A)

Issued by Local Bodies · Madurai, Tamil Nadu
Tender Value
9.58 Crore
Estimated cost
Bid Submission
20 Nov 2026
13 days left
EMD
7.19 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Madurai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Operation And Maintenance Of The Andipatty - Sedapatty Cwss In Madurai And Theni Districts Including Repair And Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 15 A)

BOQ

Name of Work:- Operation and Maintenance of the Andipatty - Sedapatty CWSS in Madurai and Theni Districts including repair and rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 15 A)
Sl. No. Item Description
1SUPPLY EARMARKED QUANTITY OF WATER NOTED AGAINST EACH CWSS IN MADURAI AND THENI DISTRICTS BY CARRYING OUT ALL THE NECESSARY WORKS SUCH AS PUMPING, ATTENDING TO LEAK AND BURST, ATTENDING TO ELECTRICAL AND MECHANICAL REPAIR WORKS, PROVIDING DISINFECTION, PREVENTIVE MAINTENANCE OF ALL INSTALLATIONS, SUMP CLEANING AND DELIVERANCE OF EARMARKED QUANTITY OF WATER TO THE BENEFICIARIES AS PER SCHEDULE AND STANDARD OPERATING PROCEDURES AND AS DIRECTED BY THE TWAD BOARD OFFICERS FOR the period from 01.01.2027 to 31.03.2029.
2Operation and Maintenance of the Andipatty - Sedapatty CWSS in Madurai and Theni Districts including repair and rectification works and supply of chemicals for the period from 01.01.2027 to 31.03.2029 (Package 15 A)
3Total Basic Value
4Add GST @18% on Basic Value
52.0 For the year 2026- 2027 (01.01.2027 to 31.03.2027)
6Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 26.336 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally 2370.24 ML (26.336*90) Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
7Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
8PVC /PSC Pipes of various sizes
9Removing the burst PSC/PVC pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipeline with water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
10350 mm dia PSC Pipe Various Classes
11400 mm dia PSC Pipe Various Classes
12600 mm dia PSC Pipe Various Classes
13700 mm dia PSC Pipe Various Classes
1450mm PVC 6KSC
1563mm PVC 4KSC
1675mm PVC 4KSC
1790mm PVC 4 KSC
18110mm PVC 4KSC
19140mm PVC 4KSC
20Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
21350 mm dia DI Pipe
22400 mm dia DI Pipe
23600 mm dia DI Pipe
24700 mm dia DI Pipe
2550mm PVC 6KSC
2663mm PVC 4KSC
2775mm PVC 4KSC
2890mm PVC 4 KSC
29110mm PVC 4KSC
30140mm PVC 4KSC
3150 mm PVC Coupler Fabricated 6 KSC
3263 mm PVC Coupler Fabricated 4 KSC
3375 mm PVC Coupler Fabricated 4 KSC
3490 mm PVC Coupler Fabricated 4 KSC
35110 mm PVC Coupler Fabricated 4 KSC
36140 mm PVC Coupler Fabricated 4 KSC
37Supply and Delivery of MJ Collars
38350 mm dia PSC Pipe Various Classes
39400 mm dia PSC Pipe Various Classes
40600 mm dia PSC Pipe Various Classes
41700 mm dia PSC Pipe Various Classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil , labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II.and as directed by TWAD Board officers
42Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
43For PSC Pipes of various classes
44Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
45350 mm dia DI Pipe
46400 mm dia DI Pipe
47600 mm dia DI Pipe
48700 mm dia DI Pipe
49Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
50350 mm dia PSC Pipe Various Classes
51400 mm dia PSC Pipe Various Classes
52600 mm dia PSC Pipe Various Classes
53700 mm dia PSC Pipe Various Classes
54Supply and delivery of Hard crete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
55350 mm dia PSC Pipe Various Classes
56400 mm dia PSC Pipe Various Classes
57600 mm dia PSC Pipe Various Classes
58700 mm dia PSC Pipe Various Classes
59Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
60350 mm dia PSC Pipe Various Classes
61400 mm dia PSC Pipe Various Classes
62600 mm dia PSC Pipe Various Classes
63700 mm dia PSC Pipe Various Classes
64Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
65350 mm dia PSC Pipe Various Classes
66400 mm dia PSC Pipe Various Classes
67600 mm dia PSC Pipe Various Classes
68700 mm dia PSC Pipe Various Classes
69Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
70For PSC Pipes of various classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items with MS Clampsets round the clock as per the standard specifications including earthwork excavation, removal of slushy soi, labour charges, civil works, cost of materials, dewatering , and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II and as directed by TWAD Board officers.
71Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
72For MS Pipes of various classes
73Supply and Delivery of MS pipes SPIRAL/LONGITUDIDNAL WELDING as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm and pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement inclusive of Transportation charges anywhere in Tamil Nadu etc., complete and as directed by TWAD Board officers
74711mm diax6.3mm thick MS Pipe Various Classes
75Hire charges for providing Gas cutting unit including cost of rent for cutting unit, consumption of gas requirred for cutting etc., complete and as directed by TWAD Board Officers.
76711mm diax6.3mm thick MS Pipe Various Classes
77Hire charges for providing 62 kva genset for lighting arrangements and welding plant including cost of diesal, conveyance charges and operation completion of all woks to satisfaction of TWAD officers.
78711mm diax6.3mm thick MS Pipe Various Classes
79Hire charges for providing welding unit including cost of rent for welding unit and cable cost of welding rods of good quality and labour charges towards welding including conveyance charges till completion of work to satisfaction of TWAD officers.
80711mm diax6.3mm thick MS Pipe Various Classes
81Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
82711mm diax6.3mm thick MS Pipe Various Classes
83Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
84711mm diax6.3mm thick MS Pipe Various Classes Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
85Rewinding of Motor and repair works to Vertical Turbine Motors including cost of all material, conveyance, labour charges for removing and reerection of Vertical Turbine Motors etc., complete and as directed by TWAD Board Officers.-150 HP
86Rewinding of Motor and repair works to Centifugal HSC Motors including cost of all material, conveyance, labour charges for removing and reerection of HSC motors etc., complete and as directed by TWAD Board Officers.-
87220 HP
88168 HP
89Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Openwell Submersible Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofsubmersible pumset etc., complete and as directed by TWAD Board Officers.
9012 HP
9118 HP
92Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Centrifugal Monoblock Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofCentrifugal Monoblock Pumpset etc., complete and as directed by TWAD Board Officers.
9310 HP
947.5 HP
952 HP Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II complete and as directed by the TWAD Board officers.
96Repair and Reconditioning works in Vertical turbine Pumpset including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Vertical turbine Pumpset etc., complete and as directed by TWAD Board Officers -150 HP
97Repair and Reconditioning works in Centifugal HSC Pumpsets including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Centifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers
98168 HP
99220 HP
100Attending Repair, rectification and reconditioning of CI Sluice valve / Double air valve/Non return Valve including cost of all material,, conveyance, labour charges for removing and reerection of CI Sluice Valve etc., complete and as directed by TWAD Board Officers.
101700 mm CI Sluice valve
102600 mm CI Sluice valve
103400 mm CI Sluice valve
104300 mm CI Sluice valve
105250 mm CI Sluice valve
106200 mm CI Sluice valve
107150 mm CI Sluice valve
108125 mm CI Sluice valve
109100 mm CI Sluice valve
11080 mm CI Sluice valve
11165 mm CI Sluice valve
11250 mm CI Sluice valve
113400 mm dia C.I NRV
114350 mm dia C.I NRV
115300 mm dia C.I NRV
116250 mm dia C.I NRV
117200 mm dia C.I NRV
11880 mm dia C.I NRV
11950 mm dia C.I NRV
120300 mm dia D.I NRV
121150 mm dia C.I Double Airvalve
122100 mm dia C.I Double Airvalve
12380 mm dia C.I Double Airvalve
12450 mm dia C.I Double Airvalve
12540 mm dia C.I Double Airvalve Attending cable fault by replacing the cable
126Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
1273.5 core 300 Sq. mm aluminium cable
128Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying in trenches inside the pump room or in air
1293.5 core 300 Sq. mm aluminium cable
130Jointing the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
1313.5 core 300 Sq. mm aluminium cable Supply and delivery of the following Electrical Works consumable items at the site of work to carryout the general maintenace works
132Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-2 etc., complete and as directed by TWAD Board Officers
133400 Amps
134325 Amps
135125 Amps
13640 Amps
137Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
138Upto 5A
1395A-10A
14010A-20A
141Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
142Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammetre, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Pushbutton switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers.
143For 5 HP Starter - 2 Nos
144Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately).
14512 HP
14618 HP
14710 HP
1487.5 HP
149Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
150630 Amps 3 Pole MCCB Switch
151400 Amps 3 Pole MCCB Switch
152Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
153630 Amps 3 Pole MCCB Switch
154400 Amps 3 Pole MCCB Switch
155Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
156100/200/300 KVAR Power capacitor at Various location
157Supply and delivery of the following GM Gate Valves inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Officers
15850 mm Gate valve
15965 mm Gate valve
16080 mm Gate valve
161100 mm Gate valve
162Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers
163Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers.
164Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers.
165Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete and as directed by TWAD Board Officers
166Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
16715.00 LL capacity of Clear water sump @ Vaigaidam
16812.00 LL capacity sump @ Thimmarasanayakkanur and Kanavai
1696.00 LL Capacity sump at Chettiyapatty
1702.00 LL Capacity elevater MSR
1711.00 LL Capacity elevater MSR
17260,000 Lit capacity MSR
17330,000 Lit capacity MSR Attending Major Repair works for following KVA/443V Transformer including dismantling, Copper dueal coat super enameled winding coils, insulation material, Transformer Oil, LV Pushing copper rod, silica gel breather, Capillary type thermometer, gasket & oil, core winding, reassessmbling & etc,. complete and as directed by TWad Board Officers
1741) For 400 KVA
175Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers
176Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
177Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
178Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
179Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
180Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
181Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
182Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
183Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
184Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
185Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
186Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers.
187Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers.
188Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers..
189Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
190Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers.
191Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers For the year 2027- 2028 (01.04.2027 to 31.03.2028)
192Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 26.559 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally (26.559*366 days) Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
193Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
194PVC /PSC/HDPE Pipes of various sizes
195Removing the burst C.I./ D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipelinewith water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
196350 mm dia PSC Pipe Various Classes
197400 mm dia PSC Pipe Various Classes
198600 mm dia PSC Pipe Various Classes
199700 mm dia PSC Pipe Various Classes
20050mm PVC 6KSC
20163mm PVC 4KSC
20275mm PVC 4KSC
20390mm PVC 4 KSC
204110mm PVC 4KSC
205140mm PVC 4KSC
206Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
207350 mm dia DI Pipe
208400 mm dia DI Pipe
209600 mm dia DI Pipe
210700 mm dia DI Pipe
21150mm PVC 6KSC
21263mm PVC 4KSC
21375mm PVC 4KSC
21490mm PVC 4 KSC
215110mm PVC 4KSC
216140mm PVC 4KSC
21750 mm PVC Coupler Fabricated 6 KSC
21863 mm PVC Coupler Fabricated 4 KSC
21975 mm PVC Coupler Fabricated 4 KSC
22090 mm PVC Coupler Fabricated 4 KSC
221110 mm PVC Coupler Fabricated 4 KSC
222140 mm PVC Coupler Fabricated 4 KSC
223Supply and Delivery of MJ Collars
224350 mm dia PSC Pipe Various Classes
225400 mm dia PSC Pipe Various Classes
226600 mm dia PSC Pipe Various Classes
227700 mm dia PSC Pipe Various Classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil , labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II.and as directed by TWAD Board officers
228Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
229For PSC Pipes of various classes
230Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
231350 mm dia DI Pipe
232400 mm dia DI Pipe
233600 mm dia DI Pipe
234700 mm dia DI Pipe
235Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
236350 mm dia PSC Pipe Various Classes
237400 mm dia PSC Pipe Various Classes
238600 mm dia PSC Pipe Various Classes
239700 mm dia PSC Pipe Various Classes
240Supply and delivery of Hard crete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
241350 mm dia PSC Pipe Various Classes
242400 mm dia PSC Pipe Various Classes
243600 mm dia PSC Pipe Various Classes
244700 mm dia PSC Pipe Various Classes
245Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
246350 mm dia PSC Pipe Various Classes
247400 mm dia PSC Pipe Various Classes
248600 mm dia PSC Pipe Various Classes
249700 mm dia PSC Pipe Various Classes
250Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
251350 mm dia PSC Pipe Various Classes
252400 mm dia PSC Pipe Various Classes
253600 mm dia PSC Pipe Various Classes
254700 mm dia PSC Pipe Various Classes
255Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
256For PSC Pipes of various classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items with MS Clampsets round the clock as per the standard specifications including earthwork excavation, removal of slushy soi, labour charges, civil works, cost of materials, dewatering , and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II and as directed by TWAD Board officers.
257Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
258For MS Pipes of various classes
259Supply and Delivery of MS pipes SPIRAL/LONGITUDIDNAL WELDING as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm and pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement inclusive of Transportation charges anywhere in Tamil Nadu etc., complete and as directed by TWAD Board officers
260711mm diax6.3mm thick MS Pipe Various Classes
261Hire charges for providing Gas cutting unit including cost of rent for cutting unit, consumption of gas requirred for cutting etc., complete and as directed by TWAD Board Officers.
262711mm diax6.3mm thick MS Pipe Various Classes
263Hire charges for providing 62 kva genset for lighting arrangements and welding plant including cost of diesal, conveyance charges and operation completion of all woks to satisfaction (SE/ Lr,.No, 281010/ F.Vedasandur/ DO II /2010 DATED: 29.10.2010 ) of TWAD officers.
264711mm diax6.3mm thick MS Pipe Various Classes
265Hire charges for providing welding unit including cost of rent for welding unit and cable cost of welding rods of good quality and labour charges towards welding including conveyance charges till completion of work to satisfaction (SE/ Lr,.No, 281010/ F.Vedasandur/ DO II /2010 DATED: 29.10.2010 ) of TWAD officers.
266711mm diax6.3mm thick MS Pipe Various Classes
267Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
268711mm diax6.3mm thick MS Pipe Various Classes
269Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
270711mm diax6.3mm thick MS Pipe Various Classes Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
271Rewinding of Motor and repair works to Vertical Turbine Motors including cost of all material, conveyance, labour charges for removing and reerection of Vertical Turbine Motors etc., complete and as directed by TWAD Board Officers.-150 HP
272Rewinding of Motor and repair works to Centifugal HSC Motors including cost of all material, conveyance, labour charges for removing and reerection of HSC motors etc., complete and as directed by TWAD Board Officers.-
273220 HP
274168 HP
275Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Openwell Submersible Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofsubmersible pumset etc., complete and as directed by TWAD Board Officers.
27612 HP
27718 HP
278Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Centrifugal Monoblock Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofCentrifugal Monoblock Pumpset etc., complete and as directed by TWAD Board Officers.
27910 HP
2807.5 HP
2812 HP Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II complete and as directed by the TWAD Board officers.
282Repair and Reconditioning works in Vertical turbine Pumpset including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Vertical turbine Pumpset etc., complete and as directed by TWAD Board Officers -150 HP
283Repair and Reconditioning works in Centifugal HSC Pumpsets including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Centifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers
284168 HP
285220 HP
286Attending Repair, rectification and reconditioning of CI Sluice valve / Double air valve/Non return Valve including cost of all material,, conveyance, labour charges for removing and reerection of CI Sluice Valve etc., complete and as directed by TWAD Board Officers.
287700 mm CI Sluice valve
288600 mm CI Sluice valve
289400 mm CI Sluice valve
290300 mm CI Sluice valve
291250 mm CI Sluice valve
292200 mm CI Sluice valve
293150 mm CI Sluice valve
294125 mm CI Sluice valve
295100 mm CI Sluice valve
29680 mm CI Sluice valve
29765 mm CI Sluice valve
29850 mm CI Sluice valve
299400 mm dia C.I NRV
300350 mm dia C.I NRV
301300 mm dia C.I NRV
302250 mm dia C.I NRV
303200 mm dia C.I NRV
30480 mm dia C.I NRV
30550 mm dia C.I NRV
306300 mm dia D.I NRV
307150 mm dia C.I Double Airvalve
308100 mm dia C.I Double Airvalve
30980 mm dia C.I Double Airvalve
31050 mm dia C.I Double Airvalve
31140 mm dia C.I Double Airvalve Attending cable fault by replacing the cable
312Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
3133.5 core 300 Sq. mm aluminium cable
314Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying in trenches inside the pump room or in air
3153.5 core 300 Sq. mm aluminium cable
316Jointing the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
3173.5 core 300 Sq. mm aluminium cable Supply and delivery of the following Electrical Works consumable items at the site of work to carryout the general maintenace works
318Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-2 etc., complete and as directed by TWAD Board Officers
319400 Amps
320325 Amps
321125 Amps
32240 Amps
323Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
324Upto 5A
3255A-10A
32610A-20A
327Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
328Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammetre, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Pushbutton switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers.
329For 5 HP Starter - 2 Nos
330Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately).
33112 HP
33218 HP
33310 HP
3347.5 HP
335Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
336630 Amps 3 Pole MCCB Switch
337400 Amps 3 Pole MCCB Switch
338Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
339630 Amps 3 Pole MCCB Switch
340400 Amps 3 Pole MCCB Switch
341Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
342100/200/300 KVAR Power capacitor at Various location
343Supply and delivery of the following GM Gate Valves inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Officers
34450 mm Gate valve
34565 mm Gate valve
34680 mm Gate valve
347100 mm Gate valve
348Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers
349Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers.
350Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers.
351Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete and as directed by TWAD Board Officers
352Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
35315.00 LL capacity of Clear water sump @ Vaigaidam
35412.00 LL capacity sump @ Thimmarasanayakkanur and Kanavai
3556.00 LL Capacity sump at Chettiyapatty
3562.00 LL Capacity elevater MSR
3571.00 LL Capacity elevater MSR
35860,000 Lit capacity MSR
35930,000 Lit capacity MSR Attending Major Repair works for following KVA/443V Transformer including dismantling, Copper dueal coat super enameled winding coils, insulation material, Transformer Oil, LV Pushing copper rod, silica gel breather, Capillary type thermometer, gasket & oil, core winding, reassessmbling & etc,. complete and as directed by TWad Board Officers
3601) For 400 KVA
361Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers
362Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
363Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
364Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
365Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
366Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
367Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
368Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
369Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
370Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
371Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
372Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers.
373Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers.
374Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers..
375Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
376Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers.
377Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers
3781) For 1000 KVA
379Labour Charges for dismantling of 1000 KVA Transformer at headworkswith all accessories by using crane etc.complete as directed by TWAD Board officers
380Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 1000KVA Transformer as per IS specifications as directed by TWAD board officers.
381Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
382Supply and delievery of 3 phase insulation material to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
383Supply and deliever1000KVA Transformer as per IS specifications as directed by TWAD board officers.
384Supply and delievery of 11KV HV bushing with Metal parts to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
385Supply and delievery of 433V LV bushing copper rod to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
386Supply and delievery of silica gel breather to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
387Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
388Supply and delievery of gasket & oil seals to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
389Supply and delievery of paint to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
390Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 1000 KVA Transformer etc.,complete as directed by TWAD board officers.
391Charges for Transformer tank cleaning and painting work to 1000 KVA Transformer as per IS Specification as directed by TWAD Board Officers.
392Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers..
393Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
394Charges for Re erection of 1000 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers.
395Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers For the year 2028- 2029 (01.04.2028 to 31.03.2029)
396Operation and Maintenance of the Electro Mechanical installations, equipments, components, pipelines valves and appurtenances, water retaining structures including protector of all schemee components from damages/ theft undertaking legal actions for such untoward incidents, preventive maintenance, disinfection and deliverance of water as per quality standards and supply of earmarked quantity of water to the beneficiaries as per Annexure 26.782 MLD, carrying out the O&M as per standard operating procedures, Acts and rules in force and as directed by TWAD Board Oficers and excluding cost towards attending leak, burst repair and replacement works to electro mechanical installations consumables for disinfection of water, cleaning of all water retaining structure, electricity etc complete and as directed by TWAD Board officers Totally (26.782*365 days) Attending Burst in the pipelines of this CWSS for the following items, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all incidental charges, etc complete within the stipulated time limit as specified in Clause 2.2.5 of General conditions of Contract - Part II. etc complete and as directed by TWAD Board officers
397Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PVC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
398PVC /PSC/HDPE Pipes of various sizes
399Removing the burst C.I./ D.I pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipeline with sound pipe including jointing and cost of refilling the pipelinewith water for retesting the pipe line etc complete. (excluding cost of sound pipe and jointing materials and earth work) and as directed by the TWAD Board Officers.
400350 mm dia PSC Pipe Various Classes
401400 mm dia PSC Pipe Various Classes
402600 mm dia PSC Pipe Various Classes
403700 mm dia PSC Pipe Various Classes
40450mm PVC 6KSC
40563mm PVC 4KSC
40675mm PVC 4KSC
40790mm PVC 4 KSC
408110mm PVC 4KSC
409140mm PVC 4KSC
410Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
411350 mm dia DI Pipe
412400 mm dia DI Pipe
413600 mm dia DI Pipe
414700 mm dia DI Pipe
41550mm PVC 6KSC
41663mm PVC 4KSC
41775mm PVC 4KSC
41890mm PVC 4 KSC
419110mm PVC 4KSC
420140mm PVC 4KSC
42150 mm PVC Coupler Fabricated 6 KSC
42263 mm PVC Coupler Fabricated 4 KSC
42375 mm PVC Coupler Fabricated 4 KSC
42490 mm PVC Coupler Fabricated 4 KSC
425110 mm PVC Coupler Fabricated 4 KSC
426140 mm PVC Coupler Fabricated 4 KSC
427Supply and Delivery of MJ Collars
428350 mm dia PSC Pipe Various Classes
429400 mm dia PSC Pipe Various Classes
430600 mm dia PSC Pipe Various Classes
431700 mm dia PSC Pipe Various Classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items round the clock as per the standard specifications including earthwork excavation ,removal of slushy soil , labour charges, civil works, cost of materials, dewatering , genset, welding unit,and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II.and as directed by TWAD Board officers
432Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
433For PSC Pipes of various classes
434Supply and delivery of the following sizes of DI, HDPE, PVC pipes and specials confirming to IS other specifications as amended from time to time with ISI marking as specified in ISI and having the required working pressure and delivery at site of work including loading, unloading, freight, stacking and transit, insurance charges, etc., complete and as directed by TWAD Board officers.
435350 mm dia DI Pipe
436400 mm dia DI Pipe
437600 mm dia DI Pipe
438700 mm dia DI Pipe
439Supply and delivery of lead wool as per sample including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
440350 mm dia PSC Pipe Various Classes
441400 mm dia PSC Pipe Various Classes
442600 mm dia PSC Pipe Various Classes
443700 mm dia PSC Pipe Various Classes
444Supply and delivery of Hard crete oil as per sample including loading, umloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
445350 mm dia PSC Pipe Various Classes
446400 mm dia PSC Pipe Various Classes
447600 mm dia PSC Pipe Various Classes
448700 mm dia PSC Pipe Various Classes
449Supply and delivery of cement including loading, unloading and transportation charges etc. complete and as directed by TWAD Bd. Officers
450350 mm dia PSC Pipe Various Classes
451400 mm dia PSC Pipe Various Classes
452600 mm dia PSC Pipe Various Classes
453700 mm dia PSC Pipe Various Classes
454Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
455350 mm dia PSC Pipe Various Classes
456400 mm dia PSC Pipe Various Classes
457600 mm dia PSC Pipe Various Classes
458700 mm dia PSC Pipe Various Classes
459Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
460For PSC Pipes of various classes Attending Leaks occurred in all the size, class and material of pipes in all the pipelines of this CWSS for the following items with MS Clampsets round the clock as per the standard specifications including earthwork excavation, removal of slushy soi, labour charges, civil works, cost of materials, dewatering , and providing night lamps, barrigading arrangements, caution sign boards ,trafic diversion arrangements and all other incidental charges, etc complete within the stipulated time limit as specified in Clause 2.8 of General conditions of Contract Part II and as directed by TWAD Board officers.
461Earth work excavation and depositing on bank in hard stiff clay, stiff black cotton soil, hard red earth, shales, murrams, ordinary gravel stoney earth mixed with small sized boulders etc., for leak rectification works for the following sizes of PSC pipes with standard trench width and depth etc., complete and as directed by the TWAD Board officers.
462For MS Pipes of various classes
463Supply and Delivery of MS pipes SPIRAL/LONGITUDIDNAL WELDING as per Table- 5 of IS 3589/2001 fabricated with Fe410 grade steel conforming to IS 3589:2001. Pipes shall be internally lined with plant applied cement mortar lining 1:2, The Lining thickness range from 6 mm to 12 mm and pipes shall be externally coated with plant applied CM 1:3, minimum 20mm thick including reinforcement inclusive of Transportation charges anywhere in Tamil Nadu etc., complete and as directed by TWAD Board officers
464711mm diax6.3mm thick MS Pipe Various Classes
465Hire charges for providing Gas cutting unit including cost of rent for cutting unit, consumption of gas requirred for cutting etc., complete and as directed by TWAD Board Officers.
466711mm diax6.3mm thick MS Pipe Various Classes
467Hire charges for providing 62 kva genset for lighting arrangements and welding plant including cost of diesal, conveyance charges and operation completion of all woks to satisfaction (SE/ Lr,.No, 281010/ F.Vedasandur/ DO II /2010 DATED: 29.10.2010 ) of TWAD officers.
468711mm diax6.3mm thick MS Pipe Various Classes
469Hire charges for providing welding unit including cost of rent for welding unit and cable cost of welding rods of good quality and labour charges towards welding including conveyance charges till completion of work to satisfaction (SE/ Lr,.No, 281010/ F.Vedasandur/ DO II /2010 DATED: 29.10.2010 ) of TWAD officers.
470711mm diax6.3mm thick MS Pipe Various Classes
471Dewatering using 5HP diesel engine pumpset including Hire charges, cost of Diesel, Engine oil, pump operator, labour charges, conveyance of pumpset and fuel to site and back, loading, unloading and any other incidental charges etc., complete. And as directed by TWAD Board officers
472711mm diax6.3mm thick MS Pipe Various Classes
473Refilling with excavated soil (other than sand)complying with standard specification in layers of 15cm watered well rammed and consolidated after the pipes and specials are laid,jointed and tested etc. and removing and depositing the surplus earth at the places shown by the TWAD Board Officers.
474711mm diax6.3mm thick MS Pipe Various Classes Carrying out the following repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per standard specification including all labour charges, cost of materials and all incidental charges within the stipulated time limit etc., complete as specified in Clause 2.8 of General conditions of Contract Part II etc as directed by TWAD Board officers
475Rewinding of Motor and repair works to Vertical Turbine Motors including cost of all material, conveyance, labour charges for removing and reerection of Vertical Turbine Motors etc., complete and as directed by TWAD Board Officers.-150 HP
476Rewinding of Motor and repair works to Centifugal HSC Motors including cost of all material, conveyance, labour charges for removing and reerection of HSC motors etc., complete and as directed by TWAD Board Officers.-
477220 HP
478168 HP
479Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Openwell Submersible Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofsubmersible pumset etc., complete and as directed by TWAD Board Officers.
48012 HP
48118 HP
482Rewinding of Motor and reconditioning of Pump and repair works to various capacity of Centrifugal Monoblock Pumpset including cost of all material, conveyance, labour charges for removing and reerection ofCentrifugal Monoblock Pumpset etc., complete and as directed by TWAD Board Officers.
48310 HP
4847.5 HP
4852 HP Carrying out the repair works occuring during the maintenance period in the Electrical, Mechanical and Elctro-mechanical items to bring back the scheme / components into normal running conditition as per specification including all charges for dismantling, repair, reinstallation, conveyance, cost of materials and all other incidental charges within the stipulated time limit etc., complete as specified in Clause 2.2.6 of General conditions of Contract Part II complete and as directed by the TWAD Board officers.
486Repair and Reconditioning works in Vertical turbine Pumpset including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Vertical turbine Pumpset etc., complete and as directed by TWAD Board Officers -150 HP
487Repair and Reconditioning works in Centifugal HSC Pumpsets including cost of all material (excluding bronze impeller), conveyance, Labour charges for removing and re erection Centifugal HSC Pumpsets etc., complete and as directed by TWAD Board Officers
488168 HP
489220 HP
490Attending Repair, rectification and reconditioning of CI Sluice valve / Double air valve/Non return Valve including cost of all material,, conveyance, labour charges for removing and reerection of CI Sluice Valve etc., complete and as directed by TWAD Board Officers.
491700 mm CI Sluice valve
492600 mm CI Sluice valve
493400 mm CI Sluice valve
494300 mm CI Sluice valve
495250 mm CI Sluice valve
496200 mm CI Sluice valve
497150 mm CI Sluice valve
498125 mm CI Sluice valve
499100 mm CI Sluice valve
50080 mm CI Sluice valve
50165 mm CI Sluice valve
50250 mm CI Sluice valve
503400 mm dia C.I NRV
504350 mm dia C.I NRV
505300 mm dia C.I NRV
506250 mm dia C.I NRV
507200 mm dia C.I NRV
50880 mm dia C.I NRV
50950 mm dia C.I NRV
510300 mm dia D.I NRV
511150 mm dia C.I Double Airvalve
512100 mm dia C.I Double Airvalve
51380 mm dia C.I Double Airvalve
51450 mm dia C.I Double Airvalve
51540 mm dia C.I Double Airvalve Attending cable fault by replacing the cable
516Supply, delivery of 1.1 KV Armoured Aluminium Conductor Cross linked Poly Ethylene insulated PVC Sheatehed cables conforming to IS 7098 (PART I)/1988 and as amended thereafter with ISI making etc., complete and as directed bt TWAD Board Officers.
5173.5 core 300 Sq. mm aluminium cable
518Laying of following cable as per I.E. rules etc., complete and as directed by TWAD Board Officers -For laying in trenches inside the pump room or in air
5193.5 core 300 Sq. mm aluminium cable
520Jointing the 1.1KV grade Armoured Aluminium Conductor cable CABLE conforming to IS 1554 PART I and as amended thereafter including jointing material and labour with ISI making etc., complete and as directed bt TWAD Board Officers
5213.5 core 300 Sq. mm aluminium cable Supply and delivery of the following Electrical Works consumable items at the site of work to carryout the general maintenace works
522Supply and delivery of Electro magnetic Contactors Suitable for Starter in AC Three Phase rating Conforming to IS/IEC 60947-4-2 etc., complete and as directed by TWAD Board Officers
523400 Amps
524325 Amps
525125 Amps
52640 Amps
527Supply and delivery of Directly operated Bimetallic Thermal overload relay which operates in case of overload and also in case of under voltage with manual and auto reset mode etc., complete and as directed by TWAD Board Officers
528Upto 5A
5295A-10A
53010A-20A
531Electric Motor protection device against single phasing. The device should protect the motor against single phasing, reverse phasing and unbalance supply. The device should be suitable for any device and have provisions for mounting in panel boards. Operate without need of any auxiliary supply.
532Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ three Phase/50HZ(+/- 5%) and 415V (+/- 10%) including Ammetre, Overload relay, under Voltage release with no Volt coil, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Pushbutton switches, including the capacitor(the cost of capacitor is to be taken separately) etc., complete and as directed by TWAD Board Officers.
533For 5 HP Starter - 2 Nos
534Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately).
53512 HP
53618 HP
53710 HP
5387.5 HP
539Supply and delivery of following Range AMPS 4 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
540630 Amps 3 Pole MCCB Switch
541400 Amps 3 Pole MCCB Switch
542Supply and delivery of following Range AMPS 3 Pole MCCB Switch (Moulted case circuit breakers) with thermo dynanmic relase inclusive of handling charges and F.O.R destination etc., complete and as directed by TWAD Board officers to control EB supply from E.B Pole to Main Panel Board
543630 Amps 3 Pole MCCB Switch
544400 Amps 3 Pole MCCB Switch
545Supply and delivery Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415/440V 50 HZ conforming to ISS:2834 with ISI marking
546100/200/300 KVAR Power capacitor at Various location
547Supply and delivery of the following GM Gate Valves inclusive of transportation charges anywhere in Tamilnadu etc., complete and as directed by TWAD Board Officers
54850 mm Gate valve
54965 mm Gate valve
55080 mm Gate valve
551100 mm Gate valve
552Supply, delivery and application of disinfection dosages as per standard norms / guidelines including cost of all disinfectents (such as bleaching powder, chlorine cylinder, silver ionization rods as applicable to this CWSS), labour charges and all incidental charges for disinfection of the water supplied from this CWSS to ensure the portable quality of disinfected water at all delivery points / tail ends, testing of water samples including additional / required / instructed dosage during the period of Flood/ Calamities etc., complete and as directed by TWAD Board Officers
553Supply, Delivery of stable bleaching powder anywhere in the schemes maintained by TWAD Board as per 1065:1989 (grade I) and amended from time to time including freight, loading, unloading, transportation, transit insurances all other incidental charges at site of work etc., complete and as directed by TWAD Board Officers.
554Supply, Delivery of Liquid chlorine Cylinder as per IS specification (with chlorine 99.80% Moisture, Na 203 Hydrogen and carbon Dioxide are to be nil) for water treatment plant in TWAD Board including loading, freight, unloading, stacking transit insurance and all other incidental charges and as directed by TWAD Board Officers.
555Supply, Delivery of Ferrice Alum (Sulphate of Alumina - Ferric) Grade - II in Loose slab required for Water Treatment Plant anywhere in the schemes maintained by TWAD Board as per ISI 299/2012 and amended from time to time including freight, loading, unloading, transportation charges etc., complete and as directed by TWAD Board Officers. Cleaning of all storage points like sumps, elevated reservoirs of various capacities available in this scheme at a frequency of once in two months including scrapping the inner side of compartment completely, scouring / dewatering / desilting using required machineries, materials, labour and all other incidental charges, application of bleaching powder/ solution etc complete and as directed by TWAD Board Officers
556Removal of sediments and depositions of sludge, silt,Particles inside the sump at various capacities by engaging required labours and diesel pumpsets and cleaning the side wall and bottom of sump using wire brushes, brooms, collecting , lifting of the deposited slit particles outside the sump, washing side wall and floor slab using bleaching powder including lighting arrangements and safety arrangements inside the sump, hire charges for the buckets, rope etc and supply of bleaching powder for cleaning purposes etc., complete and as directed by TWAD Board officers
55715.00 LL capacity of Clear water sump @ Vaigaidam
55812.00 LL capacity sump @ Thimmarasanayakkanur and Kanavai
5596.00 LL Capacity sump at Chettiyapatty
5602.00 LL Capacity elevater MSR
5611.00 LL Capacity elevater MSR
56260,000 Lit capacity MSR
56330,000 Lit capacity MSR Attending Major Repair works for following KVA/443V Transformer including dismantling, Copper dueal coat super enameled winding coils, insulation material, Transformer Oil, LV Pushing copper rod, silica gel breather, Capillary type thermometer, gasket & oil, core winding, reassessmbling & etc,. complete and as directed by TWad Board Officers
5641) For 400 KVA
565Labour Charges for dismantling of 400 KVA Transformer with all accessories by using crane etc.complete as directed by TWAD Board officers
566Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
567Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
568Supply and delievery of 3 phase insulation material to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
569Supply and delievery of new transformer oil to 400KVA Transformer as per IS specifications as directed by TWAD board officers.
570Supply and delievery of 11KV HV bushing with Metal parts to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
571Supply and delievery of 433V LV bushing copper rod to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
572Supply and delievery of silica gel breather to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
573Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
574Supply and delievery of gasket & oil seals to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
575Supply and delievery of paint to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
576Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 400 KVA Transformer etc.,complete as directed by TWAD board officers.
577Charges for Transformer tank cleaning and painting work to 400 KVA Transformer as per IS Specification as directed by TWAD Board Officers.
578Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 400 KVA Transformer as per IS specifications as directed by TWAD board officers..
579Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
580Charges for Re erection of 400 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers.
581Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers
5821) For 1000 KVA
583Labour Charges for dismantling of 1000 KVA Transformer at headworkswith all accessories by using crane etc.complete as directed by TWAD Board officers
584Supply and delievery of HV 11KV Copper Dual Coat Super enameled Winding Coils for 3 phase to 1000KVA Transformer as per IS specifications as directed by TWAD board officers.
585Supply and delievery of HV 433KV Copper Winding for 3 phase insulation to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
586Supply and delievery of 3 phase insulation material to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
587Supply and deliever1000KVA Transformer as per IS specifications as directed by TWAD board officers.
588Supply and delievery of 11KV HV bushing with Metal parts to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
589Supply and delievery of 433V LV bushing copper rod to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
590Supply and delievery of silica gel breather to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
591Supply and delievery of capillary type thermometer including accessories to 400 KVA Transformer as per IS specifications as directed by TWAD board officers.
592Supply and delievery of gasket & oil seals to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
593Supply and delievery of paint to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
594Charges for hot air chamber treatment for IR value improvement Work 900c for 2 days to 1000 KVA Transformer etc.,complete as directed by TWAD board officers.
595Charges for Transformer tank cleaning and painting work to 1000 KVA Transformer as per IS Specification as directed by TWAD Board Officers.
596Labour charges for new windings reassembling with new insulation off load tape switch connection loads with delta star connection by copper bracing work two coatings varnish apply work to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers..
597Charges for attending Core winding job to tank accessories fixing as per IS specification including testing work with loading to 1000 KVA Transformer as per IS specifications as directed by TWAD board officers.
598Charges for Re erection of 1000 KVA Tranformers and all accessories by using crane and fixing etc complete as directed by Twad Board officers.
599Conveyance charges for transformers unit from site to work shop site and work shop site to Station completion of rectification works etc complete as directed by Twad Board officers Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58434873
AUTHORITY Local Bodies
TENDER VALUE 9.58 Crore
LAST DATE 20-11-2026
Authority
Authority Name Tamil Nadu Water Supply And Drainage Board
Work Description Tender for Operation And Maintenance Of The Andipatty - Sedapatty Cwss In Madurai And Theni Districts Including Repair And Rectification Works And Supply Of Chemicals For The Period From 01.01.2027 To 31.03.2029 (Package 15 A)
Basic Detail
Tender No O and M of Andipatti Sedapatti CWSS Package 15 A
Bidding Type Tender
Location
City Madurai
State Tamil Nadu
Key Dates
Publish Date 07 Nov 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 9.58 Crore
Tender Fee Ref. Documents
EMD 7.19 Lakhs
Exemption Not Available
Document List
04c4c021-b36a-4a20-b9d5-550a55e9227b.html
BID15A.pdf
BOQ_869151.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

04c4c021-b36a-4a20-b9d5-550a55e9227b.html

pdf

BID15A.pdf

xls

BOQ_869151.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender